Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Selection optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

SU-F-T-342: Dosimetric Constraint Prediction Guided Automatic Mulit-Objective Optimization for Intensity Modulated Radiotherapy

Purpose: For intensity modulated radiotherapy, the plan optimization is time consuming with difficulties of selecting objectives and constraints, and their relative weights. A fast and automatic multi-objective optimization algorithm with abilities to predict optimal constraints and manager their trade-offs can help to solve this problem. Our purpose is to develop such a framework and algorithm for a general inverse planning. Methods: There are three main components contained in this proposed multi-objective optimization framework: prediction of initial dosimetric constraints, further adjustment of constraints and plan optimization. We firstly use our previously developed in-house geometry-dosimetry correlation model to predict the optimal patient-specific dosimetric endpoints, and treat them as initial dosimetric constraints. Secondly, we build an endpoint(organ) priority list and a constraint adjustment rule to repeatedly tune these constraints from their initial values, until every single endpoint has no room for further improvement. Lastly, we implement a voxel-independent based FMO algorithm for optimization. During the optimization, a model for tuning these voxel weighting factors respecting to constraints is created. For framework and algorithm evaluation, we randomly selected 20 IMRT prostate cases from the clinic and compared them with our automatic generated plans, in both the efficiency and plan quality. Results: For each evaluated plan, the proposed multi-objective framework could run fluently and automatically. The voxel weighting factor iteration time varied from 10 to 30 under an updated constraint, and the constraint tuning time varied from 20 to 30 for every case until no more stricter constraint is allowed. The average total costing time for the whole optimization procedure is ∼30mins. By comparing the DVHs, better OAR dose sparing could be observed in automatic generated plan, for 13 out of the 20 cases, while others are with competitive results. Conclusion: We have successfully developed a fast and automatic multi-objective optimization for intensity modulated radiotherapy. This work is supported by the National Natural Science Foundation of China (No: 81571771)

60 APPLIED LIFE SCIENCES↗

PTV-based IMPT optimization incorporating planning risk volumes vs robust optimization

Purpose: Robust optimization leads to intensity-modulated proton therapy (IMPT) plans that are less sensitive to uncertainties and superior in terms of organs-at-risk (OARs) sparing, target dose coverage, and homogeneity compared to planning target volume (PTV)-based optimized plans. Robust optimization incorporates setup and range uncertainties, which implicitly adds margins to both targets and OARs and is also able to compensate for perturbations in dose distributions within targets and OARs caused by uncertainties. In contrast, the traditional PTV-based optimization considers only setup uncertainties and adds a margin only to targets but no margins to the OARs. It also ignores range uncertainty. The purpose of this work is to determine if robustly optimized plans are superior to PTV-based plans simply because the latter do not assign margins to OARs during optimization. Methods: The authors retrospectively selected from their institutional database five patients with head and neck (H and N) cancer and one with prostate cancer for this analysis. Using their original images and prescriptions, the authors created new IMPT plans using three methods: PTV-based optimization, optimization based on the PTV and planning risk volumes (PRVs) (i.e., 'PTV+PRV-based optimization'), and robust optimization using the 'worst-case' dose distribution. The PRVs were generated by uniformly expanding OARs by 3 mm for the H and N cases and 5 mm for the prostate case. The dose-volume histograms (DVHs) from the worst-case dose distributions were used to assess and compare plan quality. Families of DVHs for each uncertainty for all structures of interest were plotted along with the nominal DVHs. The width of the 'bands' of DVHs was used to quantify the plan sensitivity to uncertainty. Results: Compared with conventional PTV-based and PTV+PRV-based planning, robust optimization led to a smaller bandwidth for the targets in the face of uncertainties {l_brace}clinical target volume [CTV] bandwidth: 0.59 [robust], 3.53 [PTV+PRV], and 3.53 [PTV] Gy (RBE){r_brace}. It also resulted in higher doses to 95% of the CTV {l_brace}D{sub 95%}: 60.8 [robust] vs 59.3 [PTV+PRV] vs 59.6 [PTV] Gy (RBE){r_brace}, smaller D{sub 5%} (doses to 5% of the CTV) minus D{sub 95%} {l_brace}D{sub 5%}- D{sub 95%}: 13.2 [robust] vs 17.5 [PTV+PRV] vs 17.2 [PTV] Gy (RBE){r_brace}. At the same time, the robust optimization method irradiated OARs less {l_brace}maximum dose to 1 cm{sup 3} of the brainstem: 48.3 [robust] vs 48.8 [PTV+PRV] vs 51.2 [PTV] Gy (RBE); mean dose to the oral cavity: 22.3 [robust] vs 22.9 [PTV+PRV] vs 26.1 [PTV] Gy (RBE); maximum dose to 1% of the normal brain: 66.0 [robust] vs 68.0 [PTV+PRV] vs 69.3 [PTV] Gy (RBE){r_brace}. Conclusions: For H and N cases studied, OAR sparing in PTV+PRV-based optimization was inferior compared to robust optimization but was superior compared to PTV-based optimization; however, target dose robustness and homogeneity were comparable in the PTV+PRV-based and PTV-based optimizations. The same pattern held for the prostate case. The authors' data suggest that the superiority of robust optimization is not due simply to its inclusion of margins for OARs, but that this is due mainly to the ability of robust optimization to compensate for perturbations in dose distributions within target volumes and normal tissues caused by uncertainties.

60 APPLIED LIFE SCIENCES↗

Modeling and Optimization of Zeolites for Contaminant Removal from Coal Combustion Impoundment Leachates

Coal Combustion Residual (CCR) landfills in the U.S. can lead to elevated contaminant concentrations in groundwater and runoff, particularly of arsenic, boron, and selenium. Zeolites can be readily synthesized from materials contained within the coal combustion ash impoundments and can be cation-exchanged to enhance adsorption capacity, selectivity, and reactivity. However, the optimization of zeolites becomes a daunting task when accounting for the variety of Si:Al ratios, the species of extra-framework cations present, and the zeolite pore structure. Molecular simulations provide methods to study and guide the design of zeolites for the sorption of contaminants from aqueous solution. In this work, models that predict the sorption of arsenic, boron, and selenium from water using cation-exchanged zeolites. Because of the lack of experimental adsorption data for these species of contaminants, models were parametrized to reproduce the results of first-principles calculations and then used to predict sorption for zeolites for a dataset containing 6000 combinations of zeolites and sorption conditions. Machine learning was used to train a model to predict sorption for materials in this database based on the results of the molecular simulations. Next, a genetic algorithm was used to optimize zeolites for the removal of each contaminant from aqueous solution for individual impoundment sites based on contaminant concentrations reported by the Electric Power Research Institute.

Findley, John↗

Connected and automated vehicles, driving systems, and control logic for info-rich eco-autonomous driving

A method for controlling automated driving operations of a vehicle includes determining vehicle origin and destination data, and generating a graphical representation of a road network with multiple candidate routes between the vehicle's origin and destination. Road-level data, including speed, turn angle, and/or gradient data, is received for each candidate route, and respective total energy uses are estimated for the vehicle to traverse across the candidate routes. Multiple candidate driving strategies, each having respective speed and acceleration profiles, are determined for the candidate route with the lowest estimated total energy use. An optimal candidate driving strategy is selected through a cost evaluation of the associated speed and acceleration profiles and forward movement simulations of the vehicle over a prediction horizon. Command signals are transmitted to the vehicle's steering and/or powertrain systems to execute control operations based on the optimal driving strategy and the candidate route with the lowest energy use.

Zhao, Junfeng↗

Study of guided wave transmission through complex junction in sodium cooled reactor

Ultrasonic guided wave techniques are seen as suitable candidates for the inspection of welded structures within sodium cooled fast reactors (SFR), as the long range propagation of guided waves without amplitude attenuation can overcome the accessibility problem due to the liquid sodium. In the context of the development of the Advanced Sodium Test Reactor for Industrial Demonstration (ASTRID), the French Atomic Commission (CEA) investigates non-destructive testing techniques based on guided wave propagation. In this work, guided wave NDT methods are applied to control the integrity of welds located in a junction-type structure welded to the main vessel. The method presented in this paper is based on the analysis of scattering matrices peculiar to each expected defect, and takes advantage of the multi-modal and dispersive characteristics of guided wave generation. In a simulation study, an algorithm developed using the CIVA software is presented. It permits selecting appropriate incident modes to optimize detection and identification of expected flawed configurations. In the second part of this paper, experimental results corresponding to a first validation step of the simulation results are presented. The goal of the experiments is to estimate the effectiveness of the incident mode selection in plates. The results show good agreement between experience and simulation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A method to dynamically balance intensity modulated radiotherapy dose between organs-at-risk

The IMRT treatment planning process typically follows a path that is based on the manner in which the planner interactively adjusts the target and organ-at-risk (OAR) constraints and priorities. The time-intensive nature of this process restricts the planner from fully understanding the dose trade-off between structures, making it unlikely that the resulting plan fully exploits the extent to which dose can be redistributed between anatomical structures. Multiobjective Pareto optimization has been used in the past to enable the planner to more thoroughly explore alternatives in dose trade-off by combining pre-generated Pareto optimal solutions in real time, thereby potentially tailoring a plan more exactly to requirements. However, generating the Pareto optimal solutions can be nonintuitive and computationally time intensive. The author presents an intuitive and fast non-Pareto approach for generating optimization sequences (prior to planning), which can then be rapidly combined by the planner in real time to yield a satisfactory plan. Each optimization sequence incrementally reduces dose to one OAR at a time, starting from the optimization solution where dose to all OARs are reduced with equal priority, until user-specified target coverage limits are violated. The sequences are computationally efficient to generate, since the optimization at each position along a sequence is initiated from the end result of the previous position in the sequence. The pre-generated optimization sequences require no user interaction. In real time, a planner can more or less instantaneously visualize a treatment plan by combining the dose distributions corresponding to user-selected positions along each of the optimization sequences (target coverage is intrinsically maintained in the combination). Interactively varying the selected positions along each of the sequences enables the planner to rapidly understand the nature of dose trade-off between structures and, thereby, arrive at a suitable plan in a short time. This methodology is demonstrated on a prostate cancer case and olfactory neuroblastoma case.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of masses in digital breast tomosynthesis: Comparison of machine learning in projection views and reconstructed slices

Purpose: In digital breast tomosynthesis (DBT), quasi-three-dimensional (3D) structural information is reconstructed from a small number of 2D projection view (PV) mammograms acquired over a limited angular range. The authors developed preliminary computer-aided diagnosis (CADx) methods for classification of malignant and benign masses and compared the effectiveness of analyzing lesion characteristics in the reconstructed DBT slices and in the PVs. Methods: A data set of MLO view DBT of 99 patients containing 107 masses (56 malignant and 51 benign) was collected at the Massachusetts General Hospital with IRB approval. The DBTs were obtained with a GE prototype system which acquired 11 PVs over a 50 deg. arc. The authors reconstructed the DBTs at 1 mm slice interval using a simultaneous algebraic reconstruction technique. The region of interest (ROI) containing the mass was marked by a radiologist in the DBT volume and the corresponding ROIs on the PVs were derived based on the imaging geometry. The subsequent processes were fully automated. For classification of masses using the DBT-slice approach, the mass on each slice was segmented by an active contour model initialized with adaptive k-means clustering. A spiculation likelihood map was generated by analysis of the gradient directions around the mass margin and spiculation features were extracted from the map. The rubber band straightening transform (RBST) was applied to a band of pixels around the segmented mass boundary. The RBST image was enhanced by Sobel filtering in the horizontal and vertical directions, from which run-length statistics texture features were extracted. Morphological features including those from the normalized radial length were designed to describe the mass shape. A feature space composed of the spiculation features, texture features, and morphological features extracted from the central slice alone and seven feature spaces obtained by averaging the corresponding features from three to 19 slices centered at the central slice were compared. For classification of masses using the PV approach, a feature extraction process similar to that described above for the DBT approach was performed on the ROIs from the individual PVs. Six feature spaces obtained from the central PV alone and by averaging the corresponding features from three to 11 PVs were formed. In each feature space for either the DBT-slice or the PV approach, a linear discriminant analysis classifier with stepwise feature selection was trained and tested using a two-loop leave-one-case-out resampling procedure. Simplex optimization was used to guide feature selection automatically within the training set in each leave-one-case-out cycle. The performance of the classifiers was evaluated by the area (A{sub z}) under the receiver operating characteristic curve. Results: The test A{sub z} values from the DBT-slice approach ranged from 0.87{+-}0.03 to 0.93{+-}0.02, while those from the PV approach ranged from 0.78{+-}0.04 to 0.84{+-}0.04. The highest test A{sub z} of 0.93{+-}0.02 from the nine-DBT-slice feature space was significantly (p=0.006) better than the highest test A{sub z} of 0.84{+-}0.04 from the nine-PV feature space. Conclusion: The features of breast lesions extracted from the DBT slices consistently provided higher classification accuracy than those extracted from the PV images.

60 APPLIED LIFE SCIENCES↗

SU-C-BRA-03: An Automated and Quick Contour Errordetection for Auto Segmentation in Online Adaptive Radiotherapy

Purpose: To develop a tool that can quickly and automatically assess contour quality generated from auto segmentation during online adaptive replanning. Methods: Due to the strict time requirement of online replanning and lack of ‘ground truth’ contours in daily images, our method starts with assessing image registration accuracy focusing on the surface of the organ in question. Several metrics tightly related to registration accuracy including Jacobian maps, contours shell deformation, and voxel-based root mean square (RMS) analysis were computed. To identify correct contours, additional metrics and an adaptive decision tree are introduced. To approve in principle, tests were performed with CT sets, planned and daily CTs acquired using a CT-on-rails during routine CT-guided RT delivery for 20 prostate cancer patients. The contours generated on daily CTs using an auto-segmentation tool (ADMIRE, Elekta, MIM) based on deformable image registration of the planning CT and daily CT were tested. Results: The deformed contours of 20 patients with total of 60 structures were manually checked as baselines. The incorrect rate of total contours is 49%. To evaluate the quality of local deformation, the Jacobian determinant (1.047±0.045) on contours has been analyzed. In an analysis of rectum contour shell deformed, the higher rate (0.41) of error contours detection was obtained compared to 0.32 with manual check. All automated detections took less than 5 seconds. Conclusion: The proposed method can effectively detect contour errors in micro and macro scope by evaluating multiple deformable registration metrics in a parallel computing process. Future work will focus on improving practicability and optimizing calculation algorithms and metric selection.

60 APPLIED LIFE SCIENCES↗

SU-E-T-618: Dosimetric Comparison of Manual and Beam Angle Optimization of Gantry Angles in IMRT for Cervical Cancer

Purpose: To evaluate the dosimetric characteristics of intensity-modulated radiotherapy (IMRT) treatment plan with beam angle optimization. Methods: Ten post-operation patients with cervical cancer were included in this analysis. Two IMRT plans using seven beams were designed in each patient. A standard coplanar equi-space beam angles were used in the first plan (plan 1), whereas the selection of beam angle was optimized by beam angle optimization algorithm in Varian Eclipse treatment planning system for the same number of beams in the second plan (plan 2). Two plans were designed for each patient with the same dose-volume constraints and prescription dose. All plans were normalized to the mean dose to PTV. The dose distribution in the target, the dose to the organs at risk and total MU were compared. Results: For conformity and homogeneity in PTV, no statistically differences were observed in the two plans. For the mean dose in bladder, plan 2 were significantly lower than plan 1(p<0.05). No statistically significant differences were observed between two plans for the mean doses in rectum, left and right femur heads. Compared with plan1, the average monitor units reduced 16% in plan 2. Conclusion: The IMRT plan based on beam angle optimization for cervical cancer could reduce the dose delivered to bladder and also reduce MU. Therefore there were some dosimetric advantages in the IMRT plan with beam angle optimization for cervical cancer.

60 APPLIED LIFE SCIENCES↗

TPSAS-NF1676L-32708-DND

Proposed Effort under Advanced Air Transport Technology (AATT): - Select advanced Al alloy with formability and additive manufacturability, high combined strength and toughness - Fabricate single-piece Integrally Stiffened Cylinders (~10 ft. dia. x 10 ft. long) with longitudinal stiffeners - Demonstrate joining technology for assembly of two cylinders into 20-ft. long fuselage structure - Optimize structural design incorporating tailored, selective reinforcement for durability and damage tolerance - Build-up window, door and circumferential ring frames with large-scale additive manufacturing - Structural test to validate manufacturing demonstration, structural models and analysis

Taminger, Karen M↗

If We Build Them, They Will Run: Automated HPC Apps Deployment and Profiling with eBPF in Cloud

The high performance computing (HPC) community is in a period of transition. The rise of AI/ML coupled with a changing landscape of resources deems portability a new metric of performance, and methods to move between on-premises and cloud environments and assess compatibility are paramount. Here we design and test a strategy for bridging the gap between traditional HPC and Kubernetes environments – first containerizing applications, providing automated orchestration to run studies, and packaging the setup with automated means to assess performance using low overhead eXtended Berkeley Packet Filter (eBPF) programs. We first assess different designs for eBPF collection, demonstrating a tradeoff between number of programs deployed on a node and overhead added. We develop 5 low overhead eBPF programs that combine with streaming ML models to assess CPU, futex, TCP, shared memory, and file access across four different builds of an HPC application for CPU and GPU. We use eBPF data to generate insights into the possible underlying etiology of scaling issues. We then assess compatibility of a well-known benchmark, HPCG, across matrices of micro-architectures and optimization levels (217 containers across 24 instance types and over 7500 runs). We provide to the community 30 applications to deploy in our automated setup and perform a scaling study from 4 to a maximum of 256 nodes for both CPU and GPU applications. Finally, we use our gained knowledge about performance to generate compatibility artifacts that are used by a newly developed Kubernetes controller to intelligently select instance type based on optimizing a figure of merit. Along with insights to scaling in this environment with a collection of applications and templates to work from, we provide an overall strategy for approaching HPC application deployment and image selection based on compatibility in cloud.

Computer science↗

Sizing and Location Selection of Medium‐Voltage Back‐to‐Back Converters for DER‐Dominated Distribution Systems

Medium‐voltage back‐to‐back (MVB2B) converters can connect two distribution systems and quantifiably transfer power between them. This function can enable the MVB2B converter to exchange distributed energy resource (DER)‐generated power between two systems and bring significant value to enhancing distribution system DER adoption. Our previous work analysed and demonstrated the value MVB2B converter can bring to DER integration. As continuous work, this paper presents a methodology that helps address the MVB2B converter sizing and location selection problem in distribution systems with high DER penetrations. The proposed methodology aims to address three critical problems for MVB2B converter implementation in the real world: (1) which distribution systems are better to be connected, (2) what converter size is appropriate for connecting the distribution systems, and (3) where the optimal connection points are in the systems for connecting the MVB2B converter. The proposed methodology has been demonstrated by case studies that include various scenarios involving distribution systems with different dominated load types and high photovoltaic penetrations. The results demonstrate that selecting the optimal converter size based on net revenue and time of return considerations leads to a balance between maximizing energy savings and minimizing financial payback periods. Furthermore, feeder pair selection based on load profile standard deviation effectively identifies systems that derive the greatest value from MVB2B integration. Finally, an optimized connection point selection approach using a voltage load sensitivity matrix ensures minimal system impact while facilitating efficient power exchange. These findings provide practical insights for the real‐world deployment of MVB2B converters to enhance DER hosting capacity and improve grid resilience.

14 SOLAR ENERGY↗

On the use of genetic algorithm to optimize industrial assets lifecycle management under safety and budget constraints

The purpose of this paper is to describe the method and tool dedicated to optimize investments planning for industrial assets. These investments may either be preventive maintenance tasks, asset enhancements or logistic investments such as spare parts purchases. The two methodological points to investigate in such an issue are: 1. The measure of the profitability of a portfolio of investments 2. The selection and planning of an optimal set of investments 3. The measure of the risk of a portfolio of investments The measure of the profitability of a set of investments in the IPOP tool is synthesised in the Net Present Value indicator. The NPV is the sum of the differences of discounted cash flows (direct costs, forced outages...) between the situations with and without a given investment. These cash flows are calculated through a pseudo-Markov reliability model representing independently the components of the industrial asset and the spare parts inventories. The component model has been widely discussed over the years but the spare part model is a new one based on some approximations that will be discussed. This model, referred as the NPV function, takes for input an investments portfolio and gives its NPV. The second issue is to optimize the NPV. If all investments were independent, this optimization would be an easy calculation, unfortunately there are two sources of dependency. The first one is introduced by the spare part model, as if components are indeed independent in their reliability model, the fact that several components use the same inventory induces a dependency. The second dependency comes from economic, technical or logistic constraints, such as a global maintenance budget limit or a safety requirement limiting the residual risk of failure of a component or group of component, making the aggregation of individual optimum not necessary feasible. The algorithm used to solve such a difficult optimization problem is a genetic algorithm. After a description of the features of the software a test case is presented showing the influence of the optimization algorithm parameters on its efficiency to find an optimal investments planning. (authors)

97 MATHEMATICS AND COMPUTING↗

Tracking Excited States in Wave Function Optimization Using Density Matrices and Variational Principles

We introduce an approach for finding individual excited states' energy stationary points in complete active space self-consistent field theory that is compatible with standard optimization methods and highly effective at overcoming difficulties due to root flipping and near-degeneracies. Inspired by both the maximum overlap method and recent progress in excited-state variational principles, our approach combines these ideas in order to track individual excited states throughout the orbital optimization process. In a series of tests involving root flipping, near-degeneracies, charge transfers, and double excitations, we show that this approach is more effective for state-specific optimization than either the naive selection of roots on the basis of energy ordering or a more direct generalization of the maximum overlap method. We offer evidence that this state-specific approach improves the performance of complete active space perturbation theory for vertical excitation energies. Furthermore, we find that the state-specific optimization can help avoid state-averaging-induced discontinuities on potential energy surfaces. With a simple implementation, a low cost, and compatibility with large active space methods, the approach is designed to be useful in a wide range of excited-state investigations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving lung cancer prognosis assessment by incorporating synthetic minority oversampling technique and score fusion method

Purpose: This study aims to investigate the potential to improve lung cancer recurrence risk prediction performance for stage I NSCLS patients by integrating oversampling, feature selection, and score fusion techniques and develop an optimal prediction model. Methods: A dataset involving 94 early stage lung cancer patients was retrospectively assembled, which includes CT images, nine clinical and biological (CB) markers, and outcome of 3-yr disease-free survival (DFS) after surgery. Among the 94 patients, 74 remained DFS and 20 had cancer recurrence. Applying a computer-aided detection scheme, tumors were segmented from the CT images and 35 quantitative image (QI) features were initially computed. Two normalized Gaussian radial basis function network (RBFN) based classifiers were built based on QI features and CB markers separately. To improve prediction performance, the authors applied a synthetic minority oversampling technique (SMOTE) and a BestFirst based feature selection method to optimize the classifiers and also tested fusion methods to combine QI and CB based prediction results. Results: Using a leave-one-case-out cross-validation (K-fold cross-validation) method, the computed areas under a receiver operating characteristic curve (AUCs) were 0.716 ± 0.071 and 0.642 ± 0.061, when using the QI and CB based classifiers, respectively. By fusion of the scores generated by the two classifiers, AUC significantly increased to 0.859 ± 0.052 (p < 0.05) with an overall prediction accuracy of 89.4%. Conclusions: This study demonstrated the feasibility of improving prediction performance by integrating SMOTE, feature selection, and score fusion techniques. Combining QI features and CB markers and performing SMOTE prior to feature selection in classifier training enabled RBFN based classifier to yield improved prediction accuracy.

60 APPLIED LIFE SCIENCES↗

Low Thermal Conductivity, High Durability Thermal Barrier Coatings for IGCC Environments

Advanced thermal barrier coatings (TBC) are crucial to improved energy efficiency in next generation gas turbine engines. The use of traditional topcoat materials, e.g. yttria-stabilized zirconia (YSZ), is limited at elevated temperatures due to (1) the accelerated undesirable phase transformations and (2) corrosive attacks by calcium-magnesium-aluminum-silicate (CMAS) deposits and moisture. The first goal of this project is to use the Solution Precursor Plasma Spray (SPPS) process to further reduce the thermal conductivity of YSZ TBCs by introducing a unique microstructural feature of layered porosity, called inter-pass boundaries (IPBs). Extensive process optimization accompanied with hundreds of spray trials as well as associated SEM cross-section and laser-flash measurements, yielded a thermal conductivity as low as 0.62 Wm⁻¹K⁻¹ in SPPS YSZ TBCs, approximately 50% reduction of APS TBCs; while other engine critical properties, such as cyclic durability, erosion resistance and sintering resistance, were characterized to be equivalent or better than APS baselines. In addition, modifications were introduced to SPPS TBCs so as to enhance their resistance to CMAS under harsh IGCC environments. Several mitigation approaches were explored, including doping the coatings with Al₂O₃ and TiO₂, applying a CMAS infiltration-inhibiting surface layer, and filling topcoat cracks with blocking substances. The efficacy of all these modifications was assessed with a set of novel CMAS-TBC interaction tests, and the moisture resistance was tested in a custom-built high-temperature moisture rig. In the end, the optimal low thermal conductivity TBC system was selected based on all evaluation tests and its processing conditions were documented. The optimal coating consisted on a thick inner layer of YSZ coating made by the SPPS process having a thermal conductivity 50% lower than standard YSZ coatings topped with a high temperature tolerant CMAS resistant gadolinium zirconate Coating made by the SPPS process. Noteworthy was the fact that the YSZ to GZO interface made by the SPPS process was not the failure location as had been observed in APS coatings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PHOTOMETRIC SELECTION OF A MASSIVE GALAXY CATALOG WITH z ≥ 0.55

We present the development of a photometrically selected massive galaxy catalog, targeting Luminous Red Galaxies (LRGs) and massive blue galaxies at redshifts of z⩾0.55. Massive galaxy candidates are selected using infrared/optical color–color cuts, with optical data from the Sloan Digital Sky Survey (SDSS) and infrared data from “unWISE” forced photometry derived from the Wide-field Infrared Survey Explorer (WISE). The selection method is based on previously developed techniques to select LRGs with z>0.5, and is optimized using receiver operating characteristic curves. The catalog contains 16,191,145 objects, selected over the full SDSS DR10 footprint. The redshift distribution of the resulting catalog is estimated using spectroscopic redshifts from the DEEP2 Galaxy Redshift Survey and photometric redshifts from COSMOS. Restframe U − B colors from DEEP2 are used to estimate LRG selection efficiency. Using DEEP2, the resulting catalog has an average redshift of z = 0.65, with a standard deviation of σ=2.0, and an average restframe of U−B=1.0, with a standard deviation of σ=0.27. Using COSMOS, the resulting catalog has an average redshift of z = 0.60, with a standard deviation of σ=1.8. We estimate 34% of the catalog to be blue galaxies with z⩾0.55. An estimated 9.6% of selected objects are blue sources with redshift z<0.55. Stellar contamination is estimated to be 1.8%.

79 ASTRONOMY AND ASTROPHYSICS↗

Nanoparticulate Iron Oxyhydroxide Controls on Aqueous Redox Chemistry and Microbial Species Distribution and Activity in Natural Environments

Under anaerobic conditions that occur in soils and sediments, some microorganisms such as species of Shewanella and Geobacter pass electrons from respiration of organic carbon to iron oxyhydroxide minerals, causing the minerals to dissolve. Microbial iron reduction occurs within natural multi-species consortia, which alter their membership and biochemistry as the result of changes in their physical and chemical surroundings. The mineral electron acceptors are often poorly defined surface coatings and colloidal aggregates composed largely of nanoscale particles. We will investigate how differences in the nanomineralogy of the subsurface drive changes in the strain makeup of the microbial consortia responsible for iron reduction. Natural microbial communities are likely to include organism types with the range of genomic potential needed to profit from the expected suite of electron accepting minerals encountered in their habitats. As we predicted that redox potential is likely to be a mineral characteristic key to strain selection, we experimentally adjusted the redox potential of electrodes tested for reproducible patterns of organism response. We hypothesized that we can drive selection for the strain with cytochromes best optimized for electron transfer to the available mineral substrate. The biochemical basis for selection was investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗