Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SLICING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Two-photon X-ray ghost microscope

This article presents a non-classical imaging mechanism that produces a diffraction-limited and magnified ghost image of the internal structure of an object through the measurement of intensity fluctuation correlation formed by two-photon interference. In principle, the lensless X-ray ghost imaging mechanism may achieve a spatial resolution determined by the wavelength and the angular diameter of the X-ray source, ∼ λ /Δ θ s , with possible reduction caused by additional optics. In addition, it has the ability to image select “slices” deep within an object, which can be used for constructing 3D view of its internal structure.

Smith, Thomas A. (ORCID:0000000275427047)↗

Building epsilon near zero materials from layered uniaxial metamaterials

Recently, there has been an explosion of activity in the fields of optics and photonics with the advent of fabrication techniques which enable the design of metamaterials which possess properties not encountered in the natural world. In this work, we are concerned with zero permittivity materials and a new scheme to design metamaterials for which all components of the dielectric tensor are approximately zero. Our approach involves the alternate layering of many, very thin, slices of two constituent metamaterials, a uniaxial layered medium and a uniaxial nanowire array. With a simple optimization strategy we demonstrate a candidate configuration which very nearly satisfies our design goal of zero permittivity.

Gray, Stephen K. [Argonne National Laboratory (ANL↗

Single-shot optical recorder with sub-picosecond resolution and scalable record length on a semiconductor wafer

In this study, we demonstrate a novel, single-shot recording technology for transient optical signals. A resolution of 0.4 ps over a record length of 54 ps was demonstrated. Here, a pump pulse crossing through a signal samples a diagonal “slice” of space–time, enabling a camera to record spatially the time content of the signal. Unlike related X (2) -based cross-correlation techniques, here the signal is sampled through optically pumped carriers that modify the refractive index of a silicon wafer. Surrounding the wafer with birefringent retarders enables two time-staggered, orthogonally polarized signal copies to probe the wafer. Recombining the copies at a final crossed polarizer destructively interferes with them, except during the brief stagger window, where a differential phase shift is incurred. This enables the integrating response of the rapidly excited but persistent carriers to be optically differentiated. Lastly, this sampling mechanism has several advantages that enable scaling to long record lengths, including making use of large, inexpensive semiconductor wafers, eliminating the need for phase matching, broad insensitivity to the spectral and angular properties of the pump, and overall hardware simplicity.

42 ENGINEERING↗

Electric field vector measurements via nanosecond electric-field-induced second-harmonic generation

Electric-field-induced second-harmonic generation, or E-FISH, has received renewed interest as a nonintrusive tool for probing electric fields in gas discharges and plasmas using ultrashort laser pulses. An important contribution of this work lies in establishing that the E-FISH method works effectively in the nanosecond regime, yielding field sensitivities of about a kV/cm at atmospheric pressure from a 16 ns pulse. Here, this is expected to broaden its applicability within the plasma community, given the wider access to conventional nanosecond laser sources. A Pockels-cell-based pulse-slicing scheme, which may be readily integrated with such nanosecond laser systems, is shown to be a complementary and cost-effective option for improving the time resolution of the electric field measurement. Using this scheme, a time resolution of ~3 ns is achieved, without any detriment to the signal sensitivity. This could prove invaluable for nonequilibrium plasma applications, where time resolution of a few nanoseconds or less is often critical. Finally, we take advantage of the field vector sensitivity of the E-FISH signal to demonstrate simultaneous measurements of both the horizontal and vertical components of the electric field.

42 ENGINEERING↗

Computational microscopy for fast widefield deep-tissue fluorescence imaging using a commercial dual-cannula probe

A solid-glass cannula serves as a micro-endoscope that can deliver excitation light deep inside tissue while also collecting emitted fluorescence. Then, we utilize deep neural networks to reconstruct images from the collected intensity distributions. By using a commercially available dual-cannula probe, and training a separate deep neural network for each cannula, we effectively double the field of view compared to prior work. We demonstrated ex vivo imaging of fluorescent beads and brain slices and in vivo imaging from whole brains. We clearly resolved 4 µm beads, with FOV from each cannula of 0.2 mm (diameter), and produced images from a depth of ∼1.2 mm in the whole brain, currently limited primarily by the labeling. Since no scanning is required, fast widefield fluorescence imaging limited primarily by the brightness of the fluorophores, collection efficiency of our system, and the frame rate of the camera becomes possible.

42 ENGINEERING↗

T staging esophageal tumors with x rays

With histopathology results typically taking several days, the ability to stage tumors during interventions could provide a step change in various cancer interventions. X-ray technology has advanced significantly in recent years with the introduction of phase-based imaging methods. These have been adapted for use in standard labs rather than specialized facilities such as synchrotrons, and approaches that enable fast 3D scans with conventional x-ray sources have been developed. This opens the possibility to produce 3D images with enhanced soft tissue contrast at a level of detail comparable to histopathology, in times sufficiently short to be compatible with use during surgical interventions. In this paper we discuss the application of one such approach to human esophagi obtained from esophagectomy interventions. We demonstrate that the image quality is sufficiently high to enable tumor T staging based on the x-ray datasets alone. Alongside detection of involved margins with potentially life-saving implications, staging tumors intra-operatively has the potential to change patient pathways, facilitating optimization of therapeutic interventions during the procedure itself. Besides a prospective intra-operative use, the availability of high-quality 3D images of entire esophageal tumors can support histopathological characterization, from enabling “right slice first time” approaches to understanding the histopathology in the full 3D context of the surrounding tumor environment.

Optics↗

Application of External-Cavity Quantum Cascade Infrared Lasers to Nanosecond Time-Resolved Infrared Spectroscopy of Condensed-Phase Samples Following Pulse Radiolysis

Pulse radiolysis, utilizing short pulses of high-energy electrons from accelerators, is a powerful method for rapidly generating reduced or oxidized species and other free radicals in solution. Combined with fast time-resolved spectroscopic detection (typically in the ultraviolet/visible/near-infrared), it is invaluable for monitoring the reactivity of species subjected to radiolysis on timescales ranging from picoseconds to seconds. However, it is often difficult to identify the transient intermediates definitively due to a lack of structural information in the spectral bands. Time-resolved vibrational spectroscopy offers the structural specificity necessary for mechanistic investigations but has received only limited application in pulse radiolysis experiments. For example, time-resolved infrared (TRIR) spectroscopy has only been applied to a handful of gas-phase studies, limited mainly by several technical challenges. We have exploited recent developments in commercial external-cavity quantum cascade laser (EC-QCL) technology to construct a nanosecond TRIR apparatus that has allowed, for the first time, TRIR spectra to be recorded following pulse radiolysis of condensed-phase samples. Near single-shot sensitivity of DeltaOD <1 x 10(-3) has been achieved, with a response time of <20 ns. Using two continuous-wave EC-QCLs, the current apparatus covers a probe region from 1890-2084 cm(-1), and TRIR spectra are acquired on a point-by-point basis by recording transient absorption decay traces at specific IR wavelengths and combining these to generate spectral time slices. The utility of the apparatus has been demonstrated by monitoring the formation and decay of the one-electron reduced form of the CO(2) reduction catalyst, [Re(I)(bpy)(CO)(3)(CH(3)CN)](+), in acetonitrile with nanosecond time resolution following pulse radiolysis. Characteristic red-shifting of the nu(CO) IR bands confirmed that one-electron reduction of the complex took place. The availability of TRIR detection with high sensitivity opens up a wide range of mechanistic pulse radiolysis investigations that were previously difficult or impossible to perform with transient UV/visible detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Colloids as Mobile Substrates for the Implantation and Integration of Differentiated Neurons into the Mammalian Brain

Neuronal degeneration and the deterioration of neuronal communication lie at the origin of many neuronal disorders, and there have been major efforts to develop cell replacement therapies for treating such diseases. One challenge, however, is that differentiated cells are challenging to transplant due to their sensitivity both to being uprooted from their cell culture growth support and to shear forces inherent in the implantation process. Here, we describe an approach to address these problems. We demonstrate that rat hippocampal neurons can be grown on colloidal particles or beads, matured and even transfected in vitro, and subsequently transplanted while adhered to the beads into the young adult rat hippocampus. The transplanted cells have a 76% cell survival rate one week post-surgery. At this time, most transplanted neurons have left their beads and elaborated long processes, similar to the host neurons. Additionally, the transplanted cells distribute uniformly across the host hippocampus. Expression of a fluorescent protein and the light-gated glutamate receptor in the transplanted neurons enabled them to be driven to fire by remote optical control. At 1-2 weeks after transplantation, calcium imaging of host brain slice shows that optical excitation of the transplanted neurons elicits activity in nearby host neurons, indicating the formation of functional transplant-host synaptic connections. After 6 months, the transplanted cell survival and overall cell distribution remained unchanged, suggesting that cells are functionally integrated. This approach, which could be extended to other cell classes such as neural stem cells and other regions of the brain, offers promising prospects for neuronal circuit repair via transplantation of in vitro differentiated, genetically engineered neurons.

59 BASIC BIOLOGICAL SCIENCES↗

Whole-Cell Analysis of Low-Density Lipoprotein Uptake by Macrophages Using STEM Tomography

Nanoparticles of heavy materials such as gold can be used as markers in quantitative electron microscopic studies of protein distributions in cells with nanometer spatial resolution. Studying nanoparticles within the context of cells is also relevant for nanotoxicological research. Here, we report a method to quantify the locations and the number of nanoparticles, and of clusters of nanoparticles inside whole eukaryotic cells in three dimensions using scanning transmission electron microscopy (STEM) tomography. Whole-mount fixed cellular samples were prepared, avoiding sectioning or slicing. The level of membrane staining was kept much lower than is common practice in transmission electron microscopy (TEM), such that the nanoparticles could be detected throughout the entire cellular thickness. Tilt-series were recorded with a limited tilt-range of 80° thereby preventing excessive beam broadening occurring at higher tilt angles. The 3D locations of the nanoparticles were nevertheless determined with high precision using computation. The obtained information differed from that obtained with conventional TEM tomography data since the nanoparticles were highlighted while only faint contrast was obtained on the cellular material. Similar as in fluorescence microscopy, a particular set of labels can be studied. This method was applied to study the fate of sequentially up-taken low-density lipoprotein (LDL) conjugated to gold nanoparticles in macrophages. Analysis of a 3D reconstruction revealed that newly up-taken LDL-gold was delivered to lysosomes containing previously up-taken LDL-gold thereby forming onion-like clusters.

59 BASIC BIOLOGICAL SCIENCES↗

Observation of spin‑wave altermagnetic splitting in MnF2

-Contents of the Data Repository: - Polarized neutron diffraction data acquired in the (HK0) scattering plane. - Inelastic neutron scattering (INS) data from both unpolarized and polarized measurements with an incident neutron energy of Ei =9 meV.- - Reduced multidimensional single-crystal datasets (MDE) and corresponding S(Q,ω) slices used to generate all figures presented in the manuscript. - Julia source code and supporting input files used for spin-wave calculations, model fitting, and simulation of neutron scattering intensity maps.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Silver Peak Innovative Exploration Project (Ram Power Inc.)

Data generated from the Silver Peak Innovative Exploration Project, in Esmeralda County, Nevada, encompasses a deep-circulation (amagmatic) meteoric-geothermal system circulating beneath basin-fill sediments locally blanketed with travertine in western Clayton Valley (lithium-rich brines from which have been mined for several decades). Spring- and shallow-borehole thermal-water geochemistry and geothermometry suggest that a Silver Peak geothermal reservoir is very likely to attain the temperature range 260- 300oF (~125-150oC), and may reach 300-340oF (~150-170oC) or higher (GeothermEx, Inc., 2006). Results of detailed geologic mapping, structural analysis, and conceptual modeling of the prospect (1) support the GeothermEx (op. cit.) assertion that the Silver Peak prospect has good potential for geothermal-power production; and (2) provide a theoretical geologic framework for further exploration and development of the resource. The Silver Peak prospect is situated in the transtensional (regional shearing coupled with extension) Walker Lane structural belt, and squarely within the late Miocene to Pliocene (11 Ma to ~5 Ma) Silver Peak-Lone Mountain metamorphic core complex (SPCC), a feature that accommodated initial displacement transfer between major right-lateral strike- slip fault zones on opposite sides of the Walker Lane. The SPCC consists essentially of a ductiley-deformed lower plate, or core, of Proterozoic metamorphic tectonites and tectonized Mesozoic granitoids separated by a regionally extensive, low-angle detachment fault from an upper plate of severely stretched and fractured structural slices of brittle, Proterozoic to Miocene-age lithologies. From a geothermal perspective, the detachment fault itself and some of the upper-plate structural sheets could function as important, if secondary, subhorizontal thermal-fluid aquifers in a Silver Peak hydrothermal system.

10km↗

Utah FORGE: Phase 3 Magnetotelluric (MT) Data

New high-quality tensor MT data at 122 sites, including the vertical magnetic field and utilizing ultra-remote referencing, have been acquired over the Utah FORGE project area. The results will be used to delineate the densities of faults and fractures in crystalline basement rocks, to define the heat sources, and to derive baseline 3D resistivity structure for later MT monitoring of temporal changes in resistivity structure following well stimulation in the EGS reservoir. There are three files here related to Utah FORGE magnetotelluric (MT) data acquisition and processing. The FORGE MT EDIs zip file contains the observed MT responses in industry-standard EDI format. For each site, there is an EDI response file that utilized a local independent reference for noise cancellation, and a file that utilized a distant reference cancelling noise associated with the DC transmission line of the Delta IPP passing down the west side of Milford Valley. These two site files could be merged as appropriate. The FORGE Model Cell Center file contains the model volume of the 3D Forge MT inversion for characterizing the resistivity structure in the project area. It was derived using finite element inversion methodology described in Wannamaker et al, in the attached FORGE Phase3 Geophysics paper, from the MT observation EDI files. It is ASCII format (.dat) and entries are defined at top of the file in a simple x-y-z-Rho listing in UTM coordinates. The element layers drape the topography so the Rho value layers are not purely horizontal slices. This greatly simplifies the listing.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Southwestern Utah Magnetotelluric (MT) Data

This comprehensive magnetotellurics (MT) dataset, which covers southwestern Utah, integrates 600 sites from various surveys, including those from the Utah FORGE, SubTER, and Play Fairway projects, all of which are linked below. The core of this dataset is the use of a 3D finite element (FE) algorithm for inversion imaging, allowing for detailed analysis of the MT data. Provided here are all .edi files, the 3D finite element mesh (with a readme file), graphic slices, node graphics, resistivity graphics, and reports on the acquisition areas and inversion.

15 GEOTHERMAL ENERGY↗

Quantifying Mesoscale Neuroanatomy Using X-Ray Microtomography

Methods for resolving the three-dimensional (3D) microstructure of the brain typically start by thinly slicing and staining the brain, followed by imaging numerous individual sections with visible light photons or electrons. In contrast, X-rays can be used to image thick samples, providing a rapid approach for producing large 3D brain maps without sectioning. Here we demonstrate the use of synchrotron X-ray microtomography (µCT) for producing mesoscale (~1 µm 3 resolution) brain maps from millimeter-scale volumes of mouse brain. We introduce a pipeline for µCT-based brain mapping that develops and integrates methods for sample preparation, imaging, and automated segmentation of cells, blood vessels, and myelinated axons, in addition to statistical analyses of these brain structures. Our results demonstrate that X-ray tomography achieves rapid quantification of large brain volumes, complementing other brain mapping and connectomics efforts.

60 APPLIED LIFE SCIENCES↗

Transport and Retention of Particulate Organic Matter in Sand: Lab Experiments and Modelling

Flow-through reactor (FTR) experiments were conducted at three different downward vertical flow rates to study the transport and retention of particulate organic matter (Chlorella powder) in riverbed sediments. This data package includes data files (.csv) regarding effluent collected from the FTRs during the experiments (time, duration, volume of each sample collection; concentration of nonreactive bromide tracer; concentration of suspended Chlorella determined by absorbance measurements) and sediment (sand) slices collected from the FTRs after the experiments (mass of Chlorella retained in 1 cm depth intervals determined by loss-on-ignition method). More detailed descriptions of data are provided in the data dictionary, and detailed methods are available in the associated MSc thesis listed in ‘Related References.’ The data dictionary and file level meta data (FLMD) are included in the data package as both .csv and .xlsx files. This data package also includes timelapse videos (.mp4) of the experiments, and modelling scripts associated with the experiments. The modelling scripts are included as MATLAB ‘live scripts’ (.mlx, which can be run using MATLAB), and are also included as .pdf and .html files with output plots included (which can be viewed without a MATLAB license and installation). The data files and modelling scripts are organized into a .zip folder for each of the three FTR experiments (three flow rates).

54 ENVIRONMENTAL SCIENCES↗

Properties of jets measured from tracks in proton-proton collisions at center-of-mass energy s = 7 TeV with the ATLAS detector

CERN-LHC. Measurement of the properties of charged particle jets produced in proton-proton collisions at a centre-of-mass energy of 7 TeV using a minimum-bias trigger. The data were taken during 2010 and have an integrated luminosity of 779 mub^{-1}. Jets are reconstructed using the anti-kT algorithm with radius parameters 0.4 and 0.6 applied to charged particles with PT > 300 MeV. The measured track-based jets are corrected back to truth-level charged particle jets, which are defined to be the jets obtained when the same algoerithm is applied to all primary charged particles with the same PT cut. Measurements of the PT cross sections, multiplicities per jet, fragmentation Z distributions, transverse momentum and charged particle radial densities relative to the jet axes are presented in slices of rapidity and transverse momentum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SECARB Airborne Magnetic and Conductivity Survey

Airborne survey data collected as part of the SECARB project from Cranfield oil site in Franklin, Mississippi. Data includes residual magnetic intensity, calculated vertical magnetic gradient, differential conductivity depth slices, and digital videos of survey flights.

Airborne↗