Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

A Mercury Model of the Molly-G Fast Burst Reactor (FBR)

In order to design neutron irradiation experiments at a given nuclear reactor, one requires a representative neutron spectrum for the configuration of the reactor that will exist during the experiment. This usually implies modeling the operation of the reactor using a neutron transport code. Since the modeling of pulsed neutron reactors is quite complex, requiring coupled modeling of neutronics and thermo-structural response, the typical methodology employs analysis of the neutron spectrum which is obtained from a static keff calculation. While this time-independent Eigenfunction is not truly representative of that during a reactor pulse, we postulate that it is a reasonable representation for our purposes. The Nuclear Survivability (NS) Program at LLNL is considering fielding such experiments at the Molly-G (‘Molybdenum Godiva-II’) Fast Burst Reactor (FBR) at the White Sands Missile Range (WSMR). The goal of these experiments is to (a) test / proof / calibrate diagnostics, and (b) test the efficacy of neutron shield configurations, before fielding at other nuclear reactors, such as the Annular Core Research Reactor (ACRR) at SNL/NM. After attempting to secure either drawings or a copy of an existing MCNP model of the Molly-G FBR from various institutions, it was decided to develop a new model for use with the Mercury Monte Carlo transport code. The model described herein will be used to design these experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Identification of Backwater Nursery Habitats of Colorado Pikeminnow in the Middle Green River, Utah, Using High-Resolution Remotely Sensed Imagery

Low-velocity channel-margin habitats serve as important nursery habitats for the endangered Colorado pikeminnow (Ptychocheilus lucius) in the middle Green River between Jensen and Ouray, Utah. These habitats, known as backwaters, are associated with emergent sand bars, and are shaped and reformed annually by peak flows. A recent synthesis of information on backwater characteristics and the factors that influence inter-annual variability in those backwaters evaluated detailed survey information collected annually since 2003 on a relatively small sample of backwaters, as well as reach-wide evaluations of backwater surface area from aerial and satellite imagery. The material presented in this report is intended to provide documentation of the specific approach we used to collect, process, and analyze data from remotely sensed imagery of the middle Green River between the U.S. Geological Survey Jensen and Ouray gages, as well as images of the river reach, delineated backwater areas, and the calculated surface area of each.

58 GEOSCIENCES↗

Petronius Offshore Oil Field Case Study

This document is one of three offshore post-primary CO 2 enhanced oil recovery project case studies that compares the modeling results from an industry standard compositional simulator (“GEM”) and a variant of the FE/NETL CO 2 Prophet Model (CO 2 Prophet Model), which determined the CO 2 Prophet Model was able to reasonably represent the performance of the CO 2 flood modeled using the more sophisticated GEM. This case study uses the Petronius oil field J-2 Sand using a quarter of a five-spot pattern design (one CO 2 injector well and five production wells), for a 40-year injection scenario. A version of the CO 2 Prophet Model is available on NETL’s website under the Collection Name: FE/NETL CO 2 Prophet Model.

02 PETROLEUM↗

Cognac Offshore Oil Field Case Study

This document is one of three offshore post-primary CO 2 enhanced oil recovery project case studies that compares the modeling results from an industry standard compositional simulator (“GEM”) and a variant of the FE/NETL CO 2 Prophet Model (CO 2 Prophet Model), which determined the CO 2 Prophet Model was able to reasonably represent the performance of the CO 2 flood modeled using the more sophisticated GEM. This case study uses the Cognac oil field J Sand, in the field’s Northeast fault block, using a line drive pattern design (one CO 2 injector and two production wells), for 10-year and 20-year injection scenarios. A version of the CO 2 Prophet Model is available on NETL’s website under the Collection Name: FE/NETL CO 2 Prophet Model.

02 PETROLEUM↗

Enhancement of Optical Efficiency of CSP Mirrors for Reducing O&M Cost via Near-Continuous Operation of Self-Cleaning Electrodynamic Screens (EDS). Final Report

Over the past decade, techno-economical advancements in solar energy systems, particularly the improvement in the conversion efficiency of PV modules made with mono-crystalline silicon solar cells from 12% to 20%, as well as the cost reduction in manufacturing by a factor of about 10%, have made it possible to achieve a levelized cost of electricity (LCOE) in PV plants that is comparable to, or less than, the cost of deriving electricity from fossil fuels. Operating PV plants in mid-latitude sun-belt regions, where the solar irradiance level is highest, provides a high annual energy-yield (kWh/kWp) due to two factors: (1) the availability of predictable high solar irradiance throughout the year with the fewest interruptions in solar flux from clouds and rain, and (2) the increased conversion efficiency of crystalline solar cells, as recombination loss has decreased with increased intensity of the sunlight that illuminates the silicon solar cells. Semi-arid and desert regions, however, are plagued by high atmospheric dust concentrations and frequent sand storms. The deposition of a layer of dust on the optical surfaces of solar collectors such as PV modules and concentrating mirrors reduces the transmission efficiency of sunlight that actually reaches the solar cells or receivers, resulting in high energy-yield soiling loss. There are two major cost components to operating a solar plant: (1) installation costs, and (2) operation-and-maintenance (O&M) costs. There is no fuel cost; hence operating a solar plant in a semi-arid or desert region provides high returns on investment if soiling losses are mitigated via efficient cleaning methods and optimized cleaning frequency. If solar collectors are not cleaned, the accumulation of dust layers on solar collectors may cause the operation of such plants in arid regions to become economically unviable. Washing solar collectors with water and detergent, as is most commonly done now, is an efficient method for cleaning. The conventional approach in utility-scale solar plants is to use a large truck with a water tank and pump system for spraying deionized water on the surface of the solar collectors. Robotic cleaning with brushes, used for many solar plants, requires lesser water for cleaning. The water consumed using semi-automated cleaning of PV modules in utility-scale solar plants is approximately 2 liters/m 2 per cleaning cycle. The total optical surface area of the solar collectors in 1 TW-scale solar installation will be more than 3 × 109 m 2 ; hence an enormous amount of water be needed for cleaning. There simply is not enough fresh water in the sun-belt areas of the world for predicted cleaning needs. In solar power plants, the estimated cost of cleaning solar collectors includes expenses related to the equipment used, labor, cost of transportation of water, the energy required for cleaning, plus ancillary costs whereas the cost of water is not considered. The water used is obtained from sources located close to plant sites, unmindful of the environmental and societal impact as the power plants are oftentimes located in regions that face severe drought. This practice is very similar to the cost calculations in deriving the levelized cost of electricity (LCOE) in conventional power plants based on burning fossil fuel such as coal and gas, while disregarding the cost of climate change and health effects. Unless a water-free or low-water cleaning method is established, the expansion of solar plants may lose public support in areas suffering long intervals of drought. The goal of this research project has been the development and application of the Electrodynamic Screen (EDS) as a means for a water-free, scalable cleaning process applicable to solar-power installations, including rooftop applications. We describe here the development of an EDS film-based cleaning process as an emerging method for use on PV modules, parabolic troughs, and heliostats. This report aims to show the feasibility of integrating or retrofitting EDS films onto the optical surfaces of solar collectors (both PV and CSP) while maintaining high transmission or reflection efficiency. The cleaning action provided by the EDS film is an active method to remove dust deposits by electrodynamic force. Current lab-scale prototype EDS films, retrofitted onto solar panels and mirrors, have shown to be capable of maintaining optical transmission or specular-reflection efficiencies higher than 90% of initial values under clean conditions. The optical surfaces of solar collectors laminated with EDS films can remove more than 90% of deposited dust when the EDS is activated for less than two minutes. As an electrodynamic dust removal process, the EDS film-based method is designed primarily for the removal of dust in solar installations located in semi-arid and desert areas, where the atmosphere is often dry and dusty and rainfall is infrequent. While EDS film application minimizes water consumption and facilitates cleaning as frequently as needed, it has limitations in removing contaminants such as soot, organic pollutants deposited as fine films on the surface, and bird droppings. The dust removal efficiency of the EDS is maximum at relative humidity RH is 40 to 50% and decreases at when RH > 65%. Many solar plant sites undergo diurnal and seasonal cycles of high ambient, early afternoon temperatures and an RH that reaches the dew point early in the morning. These variations in atmospheric conditions do not limit the operation of the EDS film. This report presents a brief review of the progress and the potential of EDS film technology for mitigating the impact of dust on solar collectors via water-free cleaning, as well as current technical challenges regarding efficiency and durability. Our experimental data on the performance of EDS films show that: (1) the dust-removal efficiency (DRE) can reach levels higher than 90%, (2) the specular reflectivity (SR) of EDS film-laminated second-surface mirrors reach levels in excess of 90%, (3) the specular reflectivity restoration (SRR) can exceed 90%, (4) the output-power restoration (OPR) of PV modules can exceed 95%, and (5) the optical transmission efficiency (TE) of the EDS films can be greater than 90%. Working with Sandia National Laboratories (NM), Corning Research and Development Corporation (NY), Eastman Kodak (NY), Tomark-Worthen Industries (NH), and EDS Chile SPA (Chile), we have produced EDS film-laminated PV modules and demonstrated their self-cleaning functions without requiring water. We have demonstrated that the operational range of EDS films will cover the expected ambient temperature of solar fields at RH cycling varying from 20 to 95% as long as the EDS films are activated in the RH range 20 to 50%. (Typical solar-field climates in deserts and semi-arid lands often reach near dew point in coastal areas.) Our experiments on the application of hydrophobic-fluorinated nanoparticle coatings on EDS film surfaces show that the EDS operational range can be extended to higher RH levels that approach the dew point. At Eastman Kodak, as one of our industrial partners, we were able to establish a process for manufacturing EDS films using flexographic printing of the electrodes onto transparent polymer films. This process utilizes an existing manufacturing line at Eastman Kodak that allows fabrication of medium-scale EDS films (26 cm × 30 cm). The manufacturing process has the capacity to produce EDS films at high production speeds. The medium-scale EDS films that have been printed at Kodak were evaluated in the lab at Boston University. The EDS films produced at Kodak were laminated at Tomark-Worthen using an industrial scale vacuum laminator to produce EDS film stacks, which can be affixed onto the optical surfaces of PV modules or concentrating mirrors. The EDS film stack consists of the EDS films that have Willow® Glass (WG) which has a thickness of 100 μm as the front surface. The WG sheets obtained from Corning Research and Development Corporation are customized in size and shape to cover the active area of the EDS films. The back surface of the EDS film stack is integrated onto the optical surface of the solar panel or mirror using optically clear adhesive (OCA) films or silicone adhesives. The OCA films (thickness 25 μm) are produced by 3M. The EDS film stacks have the architecture: WG/OCA/EDS Film/OCA/ over PV module or solar mirror. The power-supply units needed for activating the electrodes of the EDS film were designed and produced at Boston University. These power supply units provide three-phase, 1.2 kV voltage pulses at a very low current (micro-ampere) level and at a low frequency (≈ 5 Hz). The voltage pulses are applied to the electrodes in a sequence such that the train of pulses resembles a unidirectional traveling wave of electrical field on the surface of the EDS film. The dust particles on the surface become charged electrostatically and are levitated by the Coulomb force. The lateral sweeping action of the traveling electric field created by the three-phase voltages pulses then sweeps the dust off the surface. The energy consumed by the EDS electrodes is less than 0.2 Wh/m 2 /cleaning cycle, enabling energy-efficient restoration of output power (OPR) of PV module or specular reflectivity restoration (SRR) for solar mirrors. The EDS system consists of (1) an EDS film stack laminated onto the solar collectors, (2) connection of the EDS film to its power supply unit and (3) Interconnection of the power supply to PV modules or solar mirrors. Design, construction and assessment of field-testing units that have EDS stack laminated PV modules for evaluating the performance of the EDS films in solar fields is being carried out at BU. Our progress under this project, aimed at the advancement of EDS film technology, has reached DOE Technology Readiness Level (TRL) 6. Based on the extensive laboratory evaluations and limited field trials, as well as contacts with potential users, we believe that the technology has reached its commercial stage. We are conducting a cost analysis using the National Renewable Energy Laboratory (NREL) System Advisory Model (SAM) and are preparing for field trials of EDS films in different solar fields in the US, Chile, India and in the Middle East. A brief description of EDS film performance, construction and testing of the field-test unit, autonomous operation of the field-test unit for evaluating EDS performance in increasing energy yield, associated revenue savings, and water conservation is presented.

14 SOLAR ENERGY↗

Horn Mountain Offshore Oil Field Case Study

This document is one of three offshore post-primary CO 2 enhanced oil recovery project case studies that compares the modeling results from an industry standard compositional simulator (“GEM”) and a variant of the FE/NETL CO 2 Prophet Model (CO 2 Prophet Model), which determined the CO 2 Prophet Model was able to reasonably represent the performance of the CO 2 flood modeled using the more sophisticated GEM. This case study uses the Horn Mountain oil field NFB M Sand, in the field's North fault block, using three pairs of wells. Each pair of wells is a line drive pattern design (one CO 2 injector and one production well). Four 20-year injection scenarios were assessed, varying CO 2 injector well placements. A version of the CO 2 Prophet Model is available on NETL’s website under the Collection Name: FE/NETL CO 2 Prophet Model.

02 PETROLEUM↗

Biomass Combustion in a Circulating Fluidized Bed Combustor

Interest in circulating fluidized bed (CFB) boilers as a power generation technology has skyrocketed in recent years because of several advantages this technology offers over conventional boilers, such as increased gas-solid mixing resulting in higher combustion efficiency and the ability to use lower quality fuels. CFB combustors are operated at lower temperatures than conventional thermal power generation combustors, thus reducing NO x emissions. SO 2 emissions are conveniently controlled through the addition of Ca-based sulphur sorbents within the combustor. This report summarizes the current modeling effort on a 50 kW th CFB combustor with a diameter of 10 cm and a height of 5 m; designed, built, and operated at CanmetENERGY in Ottawa, Canada employing the multiphase particle-in-cell (PIC) approach in the open-source Multiphase Flow with Interphase eXchanges (MFiX) Software Suite. The MFiX-PIC model parameters for the simulation are tuned against cold-flow experiments from CanmetENERGY using 9 kg of olivine sand as the inert bed material. It is shown that for the relatively coarse fluid meshes and large parcel sizes necessitated by the scale of the simulation, filter size dependent corrections to the drag law must be incorporated to ensure accuracy of the simulation results. The validated cold flow model is extended to simulate reacting flow with torrefied hardwood as the feedstock and to validate the combustion reaction scheme. The species concentrations at the riser outlet are compared against CanmetENERGY’s experiments and show satisfactory agreement. The simulations demonstrate the ability of MFiX-PIC to accurately capture the physics and chemistry of a circulating fluidized bed combustor at bench scales, which can be further extended to pilot- and industrial-scale systems.

20 FOSSIL-FUELED POWER PLANTS↗

Scalable Geometric Modeler for Overlap Detection and Resolution (ASC IC L2 Milestone 7181 FY2020 Final Review)

The final review for the FY20 Advanced Simulation and Computing (ASC) Integrated Codes (IC) L2 Milestone #7181 was conducted on August 31, 2020 at Sandia National Laboratories in Albuquerque, New Mexico. The review panel unanimously agreed that the milestone has been successfully completed. Roshan Quadros (1543) led the milestone team and various members from the team presented the results. The review panel was comprised of staff from Sandia National Laboratories Albuquerque and California that are involved with computational engineering modeling and analysis. The panel consisted of experts in the fields of solid modeling, discretization, meshing, simulation workflows, and computational analysis including personnel Brett Clark (1543, Chair); Jay Foulk (8363); Jackie Moore (1553); Ron Kensek (1341); Ed Hoffman (8753); Dan Ibanez (1443). The presentation documented the technical approach of the team and summarized the results with sufficient detail to demonstrate both the value and the completion of the milestone. A separate SAND report was also generated with more detail to supplement the presentation. The purpose of the milestone was to advance capabilities for automatically finding, displaying, and resolving geometric overlaps in CAD models.

97 MATHEMATICS AND COMPUTING↗

Review of the Nuclear Energy Agency (NEA) Ancillary Thermodynamic Database (TDB) Volume (DRAFT REV. 0)

The Nuclear Energy Agency (NEA) Ancillary data volume comprises thermodynamic data of mineral and aqueous species that, in addition to Auxiliary Data (as referred to in previous NEA thermodynamic data volumes), is necessary to calculations of chemical interactions relevant to radioactive waste management and nuclear energy. This SAND report is a review of the NEA Ancillary data critical reviews volume of thermodynamic data parameters. The review given in this report mainly involves data comparison with other thermodynamic data assessments, analysis of thermodynamic parameters, and examination of data sources. Only new and updated data parameters were considered in this review. Overall, no major inconsistencies or errors were found as allowed by the comparisons conducted in this review. Some remarks were noted, for example, on the consideration of relevant studies and/or comparisons on the analysis and retrieval of thermodynamic data parameters not cited in the respective sections.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Diagnosing and Destroying Non-Markovian Noise

Nearly every protocol used to analyze the performance of quantum information processors is based on an assumption that the errors experienced by the device during logical operations are constant in time and are insensitive to external contexts. This assumption is pervasive, rarely stated, and almost always wrong. Quantum devices that do behave this way are termed "Markovian:' but nearly every system we have ever probed has displayed drift or crosstalk or memory effects they are all non-Markovian. Strong non-Markovianity introduces spurious effects in characterization protocols and violates assumptions of the fault-tolerance threshold theorems. This SAND report details a three year laboratory-directed research and development (LDRD) project entitled, "Diagnosing and Destroying non-Markovian Noise in Quantum Information Processors." This program was initiated to build tools to study non-Markovian dynamics and quantum systems and develop robust methodologies for eliminating it. The program achieved a number of notable successes, including the first statistically rigorous protocol for identifying and characterizing drift in quantum systems, a formalism for modeling memory effects in quantum devices, and the successful suppression of drift in a Sandia trapped-ion quantum processor.

97 MATHEMATICS AND COMPUTING↗

Site 200 - Building 225 Construction Project: Steel Pipe Abandonment Work Plan (October 2020)

In December 2019, a capped, 4-inch diameter pipe located inside a square concrete collar was discovered on the north side of a driveway leading into a construction project located at the northeast corner of First Street and Avenue and petroleum like odors were reported to Lawrence Livermore National Laboratory's (LLNL) Environment, Safety and Health (ES&H) staff. The pipe was also found to contain liquid, which was sampled. Analysis of the liquid showed the presence of refined petroleum hydrocarbons - primarily benzene, toluene, ethylbenzene and total xylenes, and lead. Based on various historical documents and maps, the pipe is assumed to be associated with one, or more of four 25,000-gallon, single-wall, concrete-construction, underground storage tanks (USTs) installed by the U.S. Department of Navy in approximately 1943. The USTs were reported to have been closed - abandoned in place and filled with sand in 1950.

54 ENVIRONMENTAL SCIENCES↗

AniMACCS User Guide

This SAND Report provides an overview of AniMACCS, the animation software developed for the MELCOR Accident Consequence Code System (MACCS). It details what users need to know in order to successfully generate animations from MACCS results, to include information on the capabilities, requirements, testing, limitations, input settings, and problem reporting instructions for AniMACCS version 1.3. Supporting information is provided in the appendices, such as guidance on required input files using both WinMACCS and running MACCS from the command line. This page left blank

97 MATHEMATICS AND COMPUTING↗

Unitary Bethe-Salpeter Methods in Two- and Three-Body Systems

The study of resonances, unstable particles formed in particle scattering, is motivated by the questions about the strong interaction and the composition of hadrons. In order to advance this study in the intermediate energy region, a variety of techniques are used. In this thesis, we present work done on two different analyses that use the principle of unitarity and the Bethe-Salpeter equation to study the resonances Lambda(1405), Sigma(1385), and a1(1260). Firstly, we perform a simultaneous analysis of Sand P-waves of the Strangeness = -1 two-body meson-baryon scattering amplitude using all low-energy data. For the first time, differential cross section data are included for chiral unitary coupled-channel models. From this model, S- and P-wave amplitudes are extracted and we observe both well-known I(JP)=0(1/2^-) S-wave states as well as a new I(JP)=1(1/2^+) state absent in quark models and lattice QCD results. Multiple statistical and phenomenological tests suggest that, while the data clearly require an I =1 P-wave resonance, the new state just accounts for the absence of the decuplet Sigma(1385)3/2+ in the model which is subsequently included in the parameterization. Secondly, we formulate the final state interaction of the a1(1260) resonance decay in a manifestly three-body-unitary parameterization and fit it to the a1(1260) lineshape measured by the ALEPH experiment. Dalitz plots calculated from this fit are presented. The work demonstrates the feasibility to numerically solve a previously derived amplitude and its generalization to isobars with spin and coupled channels. The model is a good test case because it can also be applied to other meson decays including exotic states and modified for the finite-volume problem as it arises in lattice QCD due to its manifest unitarity. The understanding of the resonances being analyzed in both the two-body work and the three-body work gives a better understanding of intermediate energy QCD.

Sadasivan, Daniel↗

Financial Analysis of Experimental Releases Conducted at Glen Canyon Dam during Water Year 2019

This report was prepared by Argonne National Laboratory in support of a financial analysis of the Glen Canyon Dam high-flow experimental release that is intended to mobilize the sand in the Colorado River with high-volume water releases from the dam and redeposit it downstream as sandbars along the river. These sandbars serve, among other things, as habitat for wildlife. This experimental release was conducted during the period from November 5 to November 8, 2018. This analysis was funded by the Colorado River Storage Project (CRSP) Office of the U.S. Department of Energy Western Area Power Administration (WAPA). CRSP markets electricity produced by hydroelectric facilities collectively known as the Salt Lake City Area Integrated Projects including dams equipped for power generation on the Colorado, Green, Gunnison, and Rio Grande Rivers and on Plateau Creek in the states of Arizona, Colorado, New Mexico, Utah, and Wyoming. Staff members in Argonne’s Energy Systems Division prepared this technical report with assistance from the WAPA CRSP and Energy Marketing and Management Offices.

13 HYDRO ENERGY↗

Bryan Mound InSAR Analysis U.S. Strategic Petroleum Reserve (2018 Addendum)

The U.S. Strategic Petroleum Reserve (SPR) is a stockpile of emergency crude oil to be tapped into if a disruption in the nation's oil supply occurs. The SPR comprises of four underground salt dome sites. Subsidence surveys have been conducted either annually or biennially at all four sites over the life of the program. Monitoring of surface behavior is a first line defense to detecting possible subsurface cavern integrity issues. Over the life of the Bryan Mound site, subsidence rates over abandoned Cavern 3 have continuously been the highest at the site. In an effort to try and understand the subsurface dynamics, specifically over Bryan Mound Cavern 3, interferometric synthetic aperture radar (InSAR) data has been collected since October 2015, which allows for the acquisition of a greater density of data over a higher frequency providing improved spatiotemporal resolution. Currently, satellite images are acquired from two orbit geometries allowing for a 2-D analysis, which provides both the true vertical and east-west horizontal displacement rates. This report serves as an addendum to the 2017 report, Bryan Mound InSAR Analysis, U.S. Strategic Petroleum Reserve, SAND 2017-6679. The latest data display an improvement in point density and precision, providing a higher confidence in the results. The results confirm, as seen in the previous analysis, that the fastest surface deformation is occurring over the southwest region of the site, where abandoned Cavern 3 is located. In addition, the horizontal displacement analyses suggest a geologic feature, such as a fault, may be contributing to the higher rates observed over Cavern 3. A loss in cavern integrity would significantly impact the site surface infrastructure.

02 PETROLEUM↗

Creating the Foundation of Next Generation Pulsed-Power Accelerator Technology

This SAND report covers the work performed under the "Creating the foundation of next-generation pulsed-power-accelerator technology" LDRD. This foundation consists of both foundational concepts and foundational components. Advances were made at both levels, with new machine concepts such as Thor and new machine components such has arc quenching charge resistors, laying a new foundation for pulsed power work at Sandia. This report attempts to summarize the numerous advances made at both of these levels under this LDRD over the last three years.

43 PARTICLE ACCELERATORS↗

Method for Calculating Delayed Gamma-Ray Response in the ACRR Central Cavity and FREC-II Cavity Using MCNP

This document presents the process for a new method developed for the characterization of the delayed gamma-ray radiation fields in pulse reactors like the Annular Core Research Reactor (ACRR) and the Fueled Ring External Cavity (FREC-II). The environments used to test this method in the ACRR were FF, LB44, PLG and CdPoly, and the environments used in the FREC-II were FF with rods-down, FF with rods-up, CdPoly with rods-down and CdPoly with rods-up. All environment configurations used the same fission product gamma-ray source energy spectrum. This method required the fission sites located in the MCNP KCODE source tapes. A FORTRAN script was written to translate and extract the coordinates for the fission sites. The 10K fission sites were then input it into an MCNP SOURCE mode script. Using a MATLAB script, a parametric analysis was done, and it helped determine that 10K fission sites are an appropriate number of coordinates to converge to the correct answer. The method gave excellent results and was tested in the ACRR, FREC-II and White Sands Missile Range (WSMR). This method can be applied to other pulse research reactors as well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sequim Bay Underwater UXO Prototype Demonstration Site: Field Operations Summary, 2020

This report provides a summary of Pacific Northwest National Laboratory’s (PNNL’s) activities to initiate Phase II development of the Sequim Bay Underwater UXO Prototype demonstration site (MR-2735) in 2020. Testbed development and field operations were conducted by PNNL’s Coastal and Marine Research Laboratory (MCRL) in support of the Strategic Environmental Research and Development Program (SERDP) and Environmental Security Technology Certification Program (ESTCP) underwater Munitions Response (MR) program. A series of standardized underwater unexploded ordnance (UXO) demonstration sites (“testbeds”) are being developed by SERDP/ESTCP to test, evaluate, and demonstrate technologies that can detect, geolocate, and classify proud and buried munitions in 0–35 m water depths. As a prototype demonstration site, Sequim Bay is a semi-enclosed marine waterbody containing sand and mud sediments with minimal clutter in 5–30 m water depths. MCRL is located at the entrance to Sequim Bay, where it provides operational, logistical, and facilities support for testbed activities.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗