Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

High hydrogen coverage on graphene via low temperature plasma with applied magnetic field

The chemical functionalization of two-dimensional materials is an effective method for tailoring their chemical and electronic properties with encouraging applications in energy, catalysis, and electronics. One exemplary 2D material with remarkable properties, graphene, can be exploited for hydrogen storage and large on/off ratio devices by hydrogen termination. In this work, we describe a promising plasma-based method to provide high hydrogen coverage on graphene. A low pressure (~10 mtorr) discharge generates a fine-tunable low-temperature hydrogen-rich plasma in the applied radial electric and axial magnetic fields. Post-run characterization of these samples using Raman spectroscopy and X-ray photoelectron spectroscopy demonstrates a higher hydrogen coverage, 35.8%, than the previously reported results using plasmas. Plasma measurements indicate that with the applied magnetic field, the density of hydrogen atoms can be more than 10 times larger than the density without the magnetic field. With the applied electric field directed away from the graphene substrate, the flux of plasma ions towards this substrate and the ion energy are insufficient to cause measurable damage to the treated 2D material. As a result, the low damage allows a relatively long treatment time of the graphene samples that contributes to the high coverage obtained in these experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative high dynamic range beam profiling for fluorescence microscopy

Modern developmental biology relies on optically sectioning fluorescence microscope techniques to produce non-destructive in vivo images of developing specimens at high resolution in three dimensions. As optimal performance of these techniques is reliant on the three-dimensional (3D) intensity profile of the illumination employed, the ability to directly record and analyze these profiles is of great use to the fluorescence microscopist or instrument builder. Though excitation beam profiles can be measured indirectly using a sample of fluorescent beads and recording the emission along the microscope detection path, we demonstrate an alternative approach where a miniature camera sensor is used directly within the illumination beam. Measurements taken using our approach are solely concerned with the illumination optics as the detection optics are not involved. We present a miniature beam profiling device and high dynamic range flux reconstruction algorithm that together are capable of accurately reproducing quantitative 3D flux maps over a large focal volume. Performance of this beam profiling system is verified within an optical test bench and demonstrated for fluorescence microscopy by profiling the low NA illumination beam of a single plane illumination microscope. The generality and success of this approach showcases a widely flexible beam amplitude diagnostic tool for use within the life sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Steady-state low thermal resistance characterization apparatus: The bulk thermal tester

The reliability of microelectronic devices is largely dependent on electronic packaging, which includes heat removal. The appropriate packaging design therefore necessitates precise knowledge of the relevant material properties, including thermal resistance and thermal conductivity. Thin materials and high conductivity layers make their thermal characterization challenging. A steady state measurement technique is presented and evaluated with the purpose to characterize samples with a thermal resistance below 100 mm{sup 2} K/W. It is based on the heat flow meter bar approach made up by two copper blocks and relies exclusively on temperature measurements from thermocouples. The importance of thermocouple calibration is emphasized in order to obtain accurate temperature readings. An in depth error analysis, based on Gaussian error propagation, is carried out. An error sensitivity analysis highlights the importance of the precise knowledge of the thermal interface materials required for the measurements. Reference measurements on Mo samples reveal a measurement uncertainty in the range of 5% and most accurate measurements are obtained at high heat fluxes. Measurement techniques for homogeneous bulk samples, layered materials, and protruding cavity samples are discussed. Ultimately, a comprehensive overview of a steady state thermal characterization technique is provided, evaluating the accuracy of sample measurements with thermal resistances well below state of the art setups. Accurate characterization of materials used in heat removal applications, such as electronic packaging, will enable more efficient designs and ultimately contribute to energy savings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transport gap in SmB 6 protected against disorder

Significance The realization of modern electrical and optoelectrical devices is possible because of the successful control of point defects in semiconductors or narrow band-gapped insulators. Recently, a new subclass of these semiconductors has been discovered, so-called topological insulators (TIs). These 3D TIs harbor a unique 2D conduction layer on the surfaces that can be potentially applicable for novel quantum devices. The access of these surface states, however, is easily hindered by bulk conduction from unintentional defects. Surprisingly, by using a unique resistance measurement in a strongly correlated TI S m B 6 , we find that typical defect signatures of a semiconductor in electrical transport are absent in the S m B 6 bulk, including samples prepared with large samarium-to-boron off-stoichiometry.

36 MATERIALS SCIENCE↗

The stability of Cl-, Br-, and I-passivated Si(100)-(2 × 1) in ambient environments for atomically-precise pattern preservation

Abstract Atomic precision advanced manufacturing (APAM) leverages the highly reactive nature of Si dangling bonds relative to H- or Cl-passivated Si to selectively adsorb precursor molecules into lithographically defined areas with sub-nanometer resolution. Due to the high reactivity of dangling bonds, this process is confined to ultra-high vacuum (UHV) environments, which currently limits its commercialization and broad-based appeal. In this work, we explore the use of halogen adatoms to preserve APAM-derived lithographic patterns outside of UHV to enable facile transfer into real-world commercial processes. Specifically, we examine the stability of H-, Cl-, Br-, and I-passivated Si(100) in inert N 2 and ambient environments. Characterization with scanning tunneling microscopy and x-ray photoelectron spectroscopy (XPS) confirmed that each of the fully passivated surfaces were resistant to oxidation in 1 atm of N 2 for up to 44 h. Varying levels of surface degradation and contamination were observed upon exposure to the laboratory ambient environment. Characterization by ex situ XPS after ambient exposures ranging from 15 min to 8 h indicated the Br– and I–passivated Si surfaces were highly resistant to degradation, while Cl–passivated Si showed signs of oxidation within minutes of ambient exposure. As a proof-of-principle demonstration of pattern preservation, a H–passivated Si sample patterned and passivated with independent Cl, Br, I, and bare Si regions was shown to maintain its integrity in all but the bare Si region post-exposure to an N 2 environment. The successful demonstration of the preservation of APAM patterns outside of UHV environments opens new possibilities for transporting atomically-precise devices outside of UHV for integrating with non-UHV processes, such as other chemistries and commercial semiconductor device processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging the flow of holes from a collimating contact in graphene

A beam of holes formed in graphene by a collimating contact is imaged using a liquid-He cooled scanning probe microscope (SPM). The mean free path of holes is greater than the device dimensions. A zigzag shaped pattern on both sides of the collimating contact absorbs holes that enter at large angles. The image charge beneath the SPM tip defects holes, and the pattern of flow is imaged by displaying the change in conductance between contacts on opposite sides, as the tip is raster scanned across the sample. Collimation is confirmed by bending hole trajectories away from the receiving contact with an applied magnetic field. The SPM images agree well with ray-tracing simulations.

36 MATERIALS SCIENCE↗

Hydrogen Retention in Lithium on Metallic Walls from “In Vacuo” Analysis in LTX and Implications for High-Z Plasma-Facing Components in NSTX-U

The application of lithium to plasma-facing components (PFCs) has long been used as a technique for wall conditioning in magnetic confinement devices to improve plasma performance. Determining the characteristics of PFCs at the time of exposure to the plasma, however, is difficult because they can only be analyzed after venting the vacuum vessel and removing them at the end of an operational period. The Materials Analysis and Particle Probe (MAPP) addresses this problem by enabling PFC samples to be exposed to plasmas, and then withdrawn into an analysis chamber without breaking vacuum. The MAPP system was used to introduce samples that matched the metallic PFCs of the Lithium Tokamak Experiment (LTX). Lithium that was subsequently evaporated onto the walls also covered the MAPP samples, which were then subject to LTX discharges. In vacuo extraction and analysis of the samples indicated that lithium oxide formed on the PFCs, but improved plasma performance persisted in LTX. The reduced recycling this suggests is consistent with separate surface science experiments that demonstrated deuterium retention in the presence of lithium oxide films. Since oxygen decreases the thermal stability of the deuterium in the film, the release of deuterium was observed below the lithium deuteride dissociation temperature. This may explain what occurred when lithium was applied to the surface of the NSTX Liquid Lithium Divertor (LLD). The LLD had segments with individual heaters, and the deuterium-alpha emission was clearly lower in the cooler regions. The plan for NSTX-U is to replace the graphite tiles with high-Z PFCs, and apply lithium to their surfaces with lithium evaporation. Experiments with lithium coatings on such PFCs suggest that deuterium could still be retained if lithium compounds form, but limiting their surface temperatures may be necessary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Functional Photoresists for Energy Applications. Final Report

Monolithic ultralow-density porous bulk materials have recently attracted much interest due to many emerging applications in the areas of catalysis, energy storage and conversion, and thermal insulation. They are also important components of high energy density (HED) and inertial confinement fusion (ICF) targets. However, despite tremendous progress that has been made in the synthesis of porous materials, deterministic and independent control over microscopic architecture, density and composition remain key issues, and their integration in high precision devices requires cost and time-intensive mechanical machining that not only reduces reproducibility by generating debris but also limits the complexity of the 3D shapes that can be realized. In this project, we overcame these limitations by developing a universal templating capability that provides deterministic and independent control over density, composition, architecture, and macroscopic sample shape. This was achieved by developing the technology to 1) 3D print ultrahigh resolution, ultra-high precision polymeric micro-lattice templates, 2) coat these templates with the desired materials, and 3) removing the template (Fig. 1a). Atomic layer deposition (ALD) provides the atomic scale coating thickness accuracy required for precisely controlling density. While this templating approach had been demonstrated in prior work, limitations in suitable photoresists, 3D print technologies, print design, and template removal techniques did not allow the fabrication of millimeter-sized high-precision parts with sub-micron resolution. To enable this technology, we developed 1) two-photon polymerization (TPP) print designs that enable the fabrication of millimeter-sized, mechanically robust polymeric templates with sub-micron resolution and 2) a continuum level TPP printing simulation capability for additional print design guidance; 3) atomistic models to study photoresist polymerization kinetics and network topography, 4) refractive index matched polymeric and preceramic TPP photoresists, and 5) functional TPP photoresists including porous voxel structures and self-immolative polymer photoresist chemistries; and 6) damage free template removal techniques that enable the fabrication of defect-free high-precision low-density foam components. We also developed a templating approach for pure carbon microlattices with a unique tube-in-tube ligament morphology. As a test platform, we pursued the fabrication of foam liners that promise to further increase the neutron yield in indirect drive ICF experiments by improving implosion symmetry control and coupling between the laser and the deuterium-tritium fuel. This application requires fabrication and integration of a ultra-high precision, millimeter-sized, thin-walled (200-400 micrometer thick), low-density (10-30 mg/cc), high atomic number (high Z) cylindrical foam tube into the gold hohlraum of an indirect drive ICF target (Fig. 1b). While our hohlraum liner test case will mainly find application in HED and ICF experiments, the underlying science will also directly apply to previously developed nanoparticle and additive manufacturing technologies and will advance those techniques as well.

36 MATERIALS SCIENCE↗

Detection of nucleic acids by multiple sequential invasive cleavages

The present invention relates to means for the detection and characterization of nucleic acid sequences, as well as variations in nucleic acid sequences. The present invention also relates to methods for forming a nucleic acid cleavage structure on a target sequence and cleaving the nucleic acid cleavage structure in a site-specific manner. The structure-specific nuclease activity of a variety of enzymes is used to cleave the target-dependent cleavage structure, thereby indicating the presence of specific nucleic acid sequences or specific variations thereof. The present invention further relates to methods and devices for the separation of nucleic acid molecules based on charge. The present invention also provides methods for the detection of non-target cleavage products via the formation of a complete and activated protein binding region. The invention further provides sensitive and specific methods for the detection of human cytomegalovirus nucleic acid in a sample.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization and application of a high-resolution microfluidic device in atmospheric ice nucleation research and integrated science teaching

Ambient ice-nucleating particles (INPs) represent an important subset of aerosol particles that facilitate heterogeneous formation of ice crystals in the atmosphere, which can impact Earth system and energy. In this work, we developed an affordable high-resolution platform to replicate atmospheric immersion freezing through the unique capabilities of microfluidics to measure INP concentration of known ice nucleation active materials, as well as high-latitude soil samples. The new instrument produced comparable and extended freezing efficiency data for a multitude of samples over the temperature range of -5 to -35 °C as compared to an existing freezing assay within known uncertainties. Moreover, the new assay was integrated into science teaching at a primarily undergraduate and Hispanic-serving institute, contributing to fostering a deeper understanding of ice nucleation processes among college students, instilling their enthusiasm for science, and addressing the critical need for a well-informed citizenry. Student research assistants were involved in both research and pedagogical development processes. Three students from our team visited the Pacific Northwest National Laboratory to help characterize physicochemical properties of our test samples and to test modeling of atmospheric ice nucleation using a box model as well as a global climate model (E3SM) for the regional-scale conditions over the North Slope of Alaska (NSA) and Southern Great Plains (SGP). We also assessed student learning experience via hands-on training, research processes, and development of educational materials. On pre- and post-participation surveys and in exit interviews, students reported personal growth as advancements in breadth of experience, research-related skill sets, and regarding their educational and career goals. They also affirmed that the methods enacted incorporated the NASA Minority University Research and Education Program (MUREP) STEM Engagement Best Practices.

58 GEOSCIENCES↗

Sensitive ion detection device and method for analysis of compounds as vapors in gases

An ion mobility spectrometer (IMS) for the detection of trace gaseous molecular compounds dissolved or suspended in a carrier gas, particularly in ambient air, without preconcentration or the trapping of analyte particles. The IMS of the invention comprises an ionization volume of greater than 5 cm.sup.3 and preferably greater than 100 cm.sup.3. The larger size ionizers of this invention enable analysis of trace (<1 ppb) of sample compounds in the gas phase. To facilitate efficient ion motion through the large volume ionization and reaction regions of the IMS, an electric field gradient can be provided in the ionization region or in both the ionization and reaction regions. The systems can be implemented with radioactive ionization sources, corona discharge ion sources or ions can be formed by photoionization. In specific embodiments, particularly when the sample gas is ambient air, the sample gas is heater prior to entry into the instrument, the instrument is run at temperatures above ambient, and the instrument can be heated by contact with heated sample gas exiting the instrument.

47 OTHER INSTRUMENTATION↗

Sensitive ion detection device and method for analysis of compounds as vapors in gases

An ion mobility spectrometer (IMS) for the detection of trace gaseous molecular compounds dissolved or suspended in a carrier gas, particularly in ambient air, without preconcentration or the trapping of analyte particles. The IMS of the invention comprises an ionization volume of greater than 5 cm.sup.3 and preferably greater than 100 cm.sup.3. The larger size ionizers of this invention enable analysis of trace (<1 ppb) of sample compounds in the gas phase. To facilitate efficient ion motion through the large volume ionization and reaction regions of the IMS, an electric field gradient can be provided in the ionization region or in both the ionization and reaction regions. The systems can be implemented with radioactive ionization sources, corona discharge ion sources or ions can be formed by photoionization. In specific embodiments, particularly when the sample gas is ambient air, the sample gas is heater prior to entry into the instrument, the instrument is run at temperatures above ambient, and the instrument can be heated by contact with heated sample gas exiting the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Variational approach to quantum state tomography based on maximal entropy formalism

Quantum state tomography is an integral part of quantum computation and offers the starting point for the validation of various quantum devices. One of the central tasks in the field of state tomography is to reconstruct, with high fidelity, the quantum states of a quantum system. From an experiment on a real quantum device, one can obtain the mean measurement values of different operators. With such data as input, in this report we employ the maximal entropy formalism to construct the least biased mixed quantum state that is consistent with the given set of expectation values. Even though, in principle, the reported formalism is quite general and should work for an arbitrary set of observables, in practice we shall demonstrate the efficacy of the algorithm on an informationally complete (IC) set of Hermitian operators. Such a set possesses the advantage of uniquely specifying a single quantum state from which the experimental measurements have been sampled and hence renders the rare opportunity not only to construct a least-biased quantum state but even replicate the exact state prepared experimentally within a preset tolerance. Here, the primary workhorse of the algorithm is reconstructing an energy function which we designate as the effective Hamiltonian of the system, and parameterizing it with Lagrange multipliers, according to the formalism of maximal entropy. These parameters are thereafter optimized variationally so that the reconstructed quantum state of the system converges to the true quantum state within an error threshold. To this end, we employ a parameterized quantum circuit and a hybrid quantum-classical variational algorithm to obtain such a target state, making our recipe easily implementable on a near-term quantum device.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Method to Estimate the Atomic Number and Mass Thickness of Intervening Materials in Uranium and Plutonium Gamma-Ray Spectroscopy Measurements

To accurately characterize shielded special nuclear materials (SNM) using passive gamma-ray spectroscopy measurement techniques, the effective atomic number and the thickness of shielding materials must be measured. Intervening materials between the source and detector may affect the estimated source isotopics (uranium enrichment and plutonium grade) for techniques which rely on raw count rates or photopeak ratios of gamma-ray lines separated in energy. Furthermore, knowledge of the surrounding materials can provide insight regarding the configuration of a device containing SNM. The described method was developed using spectra recorded using high energy resolution CdZnTe detectors, but can be expanded to any gamma-ray spectrometers with energy resolution of better than 1% FWHM at 662 keV. The effective atomic number, Z, and mass thickness of the intervening shielding material are identified by comparing the relative attenuation of different gamma-ray lines and estimating the proportion of Compton scattering interactions to photoelectric absorptions within the shield. While characteristic Kα x-rays can be used to identify shielding materials made of high Z elements, this method can be applied to all shielding materials. This algorithm has adequately estimated the effective atomic number for shields made of iron, aluminum, and polyethylene surrounding uranium samples using experimental data. The mass thicknesses of shielding materials have been estimated with a standard error of less than 1.3 g/cm2 for iron shields up to 2.5 cm thick. The effective atomic number was accurately estimated to 26 ± 5 for all iron thicknesses.

CdZnTe detectors, gamma-ray imaging, gamma-ray spe↗

Ionic charging by local imbalance at interfaces in hybrid lead halide perovskites

Identification of specific operating mechanisms becomes particularly challenging when mixed ionic-electronic conductors are used in optoelectronic devices. Ionic effects in perovskite solar cells are believed to distort operation curves and possess serious doubts about their long term stability. Current hysteresis and switchable photovoltaic characteristics have been connected to the kinetics of ion migration. However, the nature of the specific ionic mechanism (or mechanisms) able to explain the operation distortions is still poorly understood. It is observed here that the local rearrangement of ions at the electrode interfaces gives rise to commonly observed capacitive effects. Charging transients in response to step voltage stimuli using thick CH{sub 3}NH{sub 3}PbI{sub 3} samples show two main polarization processes and reveal the structure of the ionic double-layer at the interface with the non-reacting contacts. It is observed that ionic charging, with a typical response time of 10 s, is a local effect confined in the vicinity of the electrode, which entails absence of net mobile ionic concentration (space-charge) in the material bulk.

36 MATERIALS SCIENCE↗

Hydrogen retention in lithium on metallic walls from “in vacuo” analysis in LTX and implications for high-Z plasma-facing components in NSTX-U

The application of lithium to plasma-facing components (PFCs) has long been used as a technique for wall conditioning in magnetic confinement devices to improve plasma performance. Determining the characteristics of PFCs at the time of exposure to the plasma, however, is difficult because they can only be analyzed after venting the vacuum vessel and removing them at the end of an operational period. The Materials Analysis and Particle Probe (MAPP) addresses this problem here by enabling PFC samples to be exposed to plasmas, and then withdrawn into an analysis chamber without breaking vacuum. The MAPP system was used to introduce samples that matched the metallic PFCs of the Lithium Tokamak Experiment (LTX). Lithium that was subsequently evaporated onto the walls also covered the MAPP samples, which were then subject to LTX discharges. In vacuo extraction and analysis of the samples indicated that lithium oxide formed on the PFCs, but improved plasma performance persisted in LTX. The reduced recycling this suggests is consistent with separate surface science experiments that demonstrated deuterium retention in the presence of lithium oxide films. Since oxygen decreases the thermal stability of the deuterium in the film, the release of deuterium was observed below the lithium deuteride dissociation temperature. This may explain what occurred when lithium was applied to the surface of the NSTX Liquid Lithium Divertor (LLD). The LLD had segments with individual heaters, and the deuterium-alpha emission was clearly lower in the cooler regions. The plan for NSTX-U is to replace the graphite tiles with high-Z PFCs, and apply lithium to their surfaces with lithium evaporation. Experiments with lithium coatings on such PFCs suggest that deuterium could still be retained if lithium compounds form, but limiting their surface temperatures may be necessary.

42 ENGINEERING↗

Direct measurement and calculation of rubber bulk modulus by piston-cylinder method using conventional mechanical testing equipment

This article describes a method to directly measure the bulk modulus of rubber using a piston-cylinder type apparatus. The function of the testing apparatus is to reliably transfer load to the water inside the vessel and allow for the accurate and continuous measurement of volumetric displacement as the contents are compressed. During the test, load is applied to a piston-cylinder containing the rubber test sample and water using a conventional mechanical testing load frame. Load and the travel of the piston are recorded by a load cell and extensometer, respectfully. A brass or stainless steel plug of the same dimensions as the test sample is tested as a control sample to isolate the compliance of the system, including the compressibility of water and compliance of the piston-cylinder. The results from this control test are used to disincorporate the compliance of the system from the sample test results. Load-linear displacement data are mathematically converted to pressure-volumetric displacement data, from which bulk modulus is calculated. The test apparatus and method are validated using the known bulk modulus of water. Finally, the bulk modulus for two similar rubbers is evaluated. The validity of the results and limitations of the device are discussed.

36 MATERIALS SCIENCE↗

New capability for indirect neutron capture measurements: The DICER instrument at LANSCE

The Device for Indirect Capture on Radionuclides (DICER) implements a new indirect technique for (n,γ) studies in which the neutron capture rate is determined from analysis of resonance neutron transmission data. The DICER instrument and associated radionuclide production at the Isotope Production Facility (IPF), both at the Los Alamos Neutron Science Center (LANSCE), as well radioactive sample fabrication, have been under development in the last few years. First measurements on a radioactive sample ( 88 Zr, t ½ =83.4 days), which was recently reported to have an extremely large thermal neutron capture cross section and resonance integral, are planned for the winter of 2021. A performance overview, brief details on the 88Zr fabrication and proof of good operation results will be presented.

47 OTHER INSTRUMENTATION↗