Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Relative accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Accuracy of the post-Newtonian approximation: Optimal asymptotic expansion for quasicircular, extreme-mass ratio inspirals

We study the accuracy of the post-Newtonian (PN) approximation and its formal region of validity, by investigating its optimal asymptotic expansion for the quasicircular, adiabatic inspiral of a point particle into a Schwarzschild black hole. By comparing the PN expansion of the energy flux to numerical calculations in the perturbative Teukolsky formalism, we show that (i) the inclusion of higher multipoles is necessary to establish the accuracy of high-order PN terms, and (ii) the region of validity of PN theory is largest at relative O(1/c{sup 6}) (3PN order). The latter result suggests that the series diverges beyond 3PN order, at least in the extreme-mass-ratio limit, probably due to the appearance of logarithmic terms in the energy flux. The study presented here is a first formal attempt to determine the region of validity of the PN approximation using asymptotic analysis. Therefore, it should serve as a template to perform similar studies on other systems, such as comparable-mass quasicircular inspirals computed by high-accuracy numerical relativistic simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Frequency standards based on ultracold atoms in tests of general relativity, navigation and gravimetry

Research and development in the field of optical clocks based on ultracold atoms and ions have enabled the relative uncertainty in frequency to be reduced down to a few parts in 10{sup 18}. The use of novel, precise frequency comparison methods opens up new possibilities for basic research (sensitive tests of general relativity, a search for a drift of fundamental constants and a search for ‘dark matter’) as well as for state-of-the-art navigation and gravimetry. We discuss the key methods that are used in creating precision clocks (including transportable clocks) based on ultracold atoms and ions and the feasibility of using them in resolving current relativistic gravimetry issues. (paper)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-I-99: Estimation of Effective Charge Distribution by Dual-Energy CT Reconstruction

Purpose: Computed Tomography (CT) is a method to produce slice image of specific volume from the scanned x-ray projection images. The contrast of CT image is correlated with the attenuation coefficients of the x-ray in the object. The attenuation coefficient is strongly dependent on the x-ray energy and the effective charge of the material. The purpose of this presentation is to show the effective charge distribution predicted by CT images reconstructed with kilovoltage(kV) and megavoltage(MV) x-ray energy. Methods: The attenuation coefficients of x-ray can be characterized by cross section of photoionization and Compton scattering for the specific xray energy. In particular, the photoionization cross section is strongly correlated with the effective charge of the object. Hence we can calculate effective charge by solving the coupled equation between the attenuation coefficient and the theoretical cross section. For this study, we use the megavoltage (MV) and kilovoltage (kV) x-rays of Elekta Synergy as the dual source x-ray, and CT image of the Phantom Laboratory CatPhan is reconstructed by the filtered back projection (FBP) and iterative algorithm for cone-beam CT (CBCT). Results: We report attenuation coefficients of each component of the CatPhan specified by each x-ray source. Also the effective charge distribution is evaluated by the MV and kV dual x-ray sources. The predicted effective charges are comparable with the nominal ones. Conclusion: We developed the MV and kV dual-source CBCT reconstruction to yield the effective charge distribution. For more accuracy, it is critical to remove an effect of the scattering photon in the CBCT reconstruction algorithm. The finding will be fine reference of the effective charge of tissue and lead to the more realistic absorbed-dose calculation. This work was partly supported by the JSPS Core-to-Core Program(No. 23003), and this work was partly supported by JSPS KAKENHI 24234567.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MESA polarimetry chain and the status of its double scattering polarimeter

We plan to have two independent polarimetry systems at MESA based on totally different physical processes. A first one tries to minimize the systematic uncertainties in double polarized Mo/ller scattering, which is to be achieved by stored hydrogen atoms in an atomic trap (Hydro-Mo/ller-Polarimeter). The other one relies on the equality of polarizing and analyzing power which allows to measure the effective analyzing power of a polarimeter with very high accuracy. Since the status of Hydro-Mo/ller is presented in a separate paper we concentrate on the double scattering polarimeter in this article.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated intraoperative calibration for prostate cancer brachytherapy

Purpose: Prostate cancer brachytherapy relies on an accurate spatial registration between the implant needles and the TRUS image, called ''calibration''. The authors propose a new device and a fast, automatic method to calibrate the brachytherapy system in the operating room, with instant error feedback. Methods: A device was CAD-designed and precision-engineered, which mechanically couples a calibration phantom with an exact replica of the standard brachytherapy template. From real-time TRUS images acquired from the calibration device and processed by the calibration system, the coordinate transformation between the brachytherapy template and the TRUS images was computed automatically. The system instantly generated a report of the target reconstruction accuracy based on the current calibration outcome. Results: Four types of validation tests were conducted. First, 50 independent, real-time calibration trials yielded an average of 0.57 {+-} 0.13 mm line reconstruction error (LRE) relative to ground truth. Second, the averaged LRE was 0.37 {+-} 0.25 mm relative to ground truth in tests with six different commercial TRUS scanners operating at similar imaging settings. Furthermore, testing with five different commercial stepper systems yielded an average of 0.29 {+-} 0.16 mm LRE relative to ground truth. Finally, the system achieved an average of 0.56 {+-} 0.27 mm target registration error (TRE) relative to ground truth in needle insertion tests through the template in a water tank. Conclusions: The proposed automatic, intraoperative calibration system for prostate cancer brachytherapy has achieved high accuracy, precision, and robustness.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mass- and energy-analyses of ions from plasma by means of a miniature Thomson spectrometer

The paper presents an improved version of a miniature mass-spectrometer of the Thomson-type, which has been adopted for ion analysis near the dense plasma region inside a vacuum chamber. Problems connected with the separation of ions from plasma streams are considered. Input diaphragms and pumping systems, needed to ensure good vacuum inside the analyzing region, are described. The application of the miniature Thomson-type analyzer is illustrated by ion parabolas recorded in plasma-focus facility and rod plasma injector experiment. A quantitative analysis of the recorded ion parabolas is presented. Factors influencing accuracy of the ion analysis are discussed and methods of the spectrometer calibration are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A calorimetric probe for plasma diagnostics

A calorimetric probe for plasma diagnostics is presented, which allows measurements of the power taken by a test substrate. The substrate can be biased and used as an electric probe in order to obtain information about the composition of the total heating power. A new calibration technique for calorimetric probes, which uses monoenergetic electrons at low pressure, has been developed for an improved accuracy. The use of the probe is exemplified with an experiment where both energetic neutral atoms and ions heat the test substrate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Red giant stars from the Sloan digital sky survey. II. Distances

We present distance determinations for a large and clean sample of red giant branch stars selected from the ninth data release of the Sloan Digital Sky Survey. The distances are calculated based on both observational cluster fiducials and theoretical isochrones. Distributions of distances from the two methods are very similar with peaks at about 10 kpc and tails extending to more than 70 kpc. We find that distances from the two methods agree well for the majority of the sample stars; though, on average, distances based on isochrones are 10% higher than those based on fiducials. We test the accuracy of our distance determinations using 332 stars from 10 Galactic globular and open clusters. The average relative deviation from the literature cluster distances is 4% for the fiducial-based distances and 8% for the isochrone-based distances, both of which are within the uncertainties. We find that the effective temperature and surface gravity derived from low-resolution spectra are not accurate enough to essentially improve the performance of distance determinations. However, for stars with significant extinction, effective temperature may help to better constrain their distances to some extent. We make our sample stars and their distances available from an online catalog. The catalog comprises 17,941 stars with reasonable distance estimations reaching to more than 70 kpc, which is suitable for the investigation of the formation and evolution of the Galaxy, especially the Galactic halo.

79 ASTRONOMY AND ASTROPHYSICS↗

Applying Quadrature Rules with Multiple Nodes to Solving Integral Equations

There are many procedures for the numerical solution of Fredholm integral equations. The main idea in these procedures is accuracy of the solution. In this paper, we use Gaussian quadrature with multiple nodes to improve the solution of these integral equations. The application of this method is illustrated via some examples, the related tables are given at the end.

97 MATHEMATICS AND COMPUTING↗

A comparative assessment of monthly mean wind speed products over the global ocean

The accurate estimation of marine wind speed is important for climate and air–sea interaction applications. There are many datasets of monthly mean wind speeds available based either on in situ measurements, satellite retrievals, atmospheric reanalysis assimilating both in situ and satellite data and blended datasets combining some or all of these other data sources. Twelve different monthly mean wind speed datasets are compared for the period from 1987 to 2009. The results suggest that we cannot presently be confident that the mean wind speed over the ocean is known to the accuracy required for the calculation of air–sea heat fluxes. Comparisons are complicated by different representations of wind speed being presented in different datasets. The in situ and reanalysis datasets present stability-dependent, earth-relative, wind speeds adjusted to a reference level of 10 m. The satellite and blended datasets present neutral equivalent, surface-relative, speeds adjusted to a reference level of 10 m. Differences between these estimates depend on atmospheric stability and ocean currents and can be greater than the required accuracy target. The adjustment for stability is itself uncertain but it is shown that these uncertainties are likely to be smaller than biases caused when the effects of stability are neglected. Further differences among the datasets are identified. Biases are caused by unidentified rain in Ku-band scatterometer-derived wind speeds and by atmospheric effects on passive microwave wind retrievals. When satellite observations affected by rain are removed a fair-weather bias remains. Some datasets are biased low in coastal regions by the effects of lower wind speeds over land in atmospheric models affecting wind speeds near the coast. All these uncertainties combine to give a wide range of estimates of monthly mean wind speed for the chosen datasets with uncertainty in mean values, spatial patterns and changes over time.

54 ENVIRONMENTAL SCIENCES↗

Assessment of the accuracy of coupled cluster perturbation theory for open-shell systems. II. Quadruples expansions

We extend our assessment of the potential of perturbative coupled cluster (CC) expansions for a test set of open-shell atoms and organic radicals to the description of quadruple excitations. Namely, the second- through sixth-order models of the recently proposed CCSDT(Q–n) quadruples series [J. J. Eriksen et al., J. Chem. Phys. 140, 064108 (2014)] are compared to the prominent CCSDT(Q) and ΛCCSDT(Q) models. From a comparison of the models in terms of their recovery of total CC singles, doubles, triples, and quadruples (CCSDTQ) energies, we find that the performance of the CCSDT(Q–n) models is independent of the reference used (unrestricted or restricted (open-shell) Hartree-Fock), in contrast to the CCSDT(Q) and ΛCCSDT(Q) models, for which the accuracy is strongly dependent on the spin of the molecular ground state. By further comparing the ability of the models to recover relative CCSDTQ total atomization energies, the discrepancy between them is found to be even more pronounced, stressing how a balanced description of both closed- and open-shell species—as found in the CCSDT(Q–n) models—is indeed of paramount importance if any perturbative CC model is to be of chemical relevance for high-accuracy applications. In particular, the third-order CCSDT(Q–3) model is found to offer an encouraging alternative to the existing choices of quadruples models used in modern computational thermochemistry, since the model is still only of moderate cost, albeit markedly more costly than, e.g., the CCSDT(Q) and ΛCCSDT(Q) models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A subdivision-stabilized B-spline mixed material point method

Subjected to external loadings, polymeric materials, e.g., biological tissues, hydrogels, and elastomers, may undergo extreme, nearly incompressible, (self-)contact deformations. For numerical modeling employing mesh-based techniques such as the finite element method (FEM), these deformations pose significant challenges due to large distortions in the deformed geometry, accuracy issues stemming from volumetric locking effects, and increased computational cost from complex contact searches. As an alternative to mesh-based methods, the material point method (MPM), a continuum-based particle technique, is gaining attention for its ability to handle extreme distortions and capture no-slip contact without added cost. For nearly incompressible material behaviors, while mixed formulations can address locking effects by treating displacements and pressure as independent fields, they can suffer from numerical instabilities close to the incompressibility limit due to the violation of the inf-sup condition, leading to inaccurate nodal pressure solutions. Here we propose an efficient and stable mixed B-spline material point method with highest achievable regularity for quasi-compressible polymeric materials. Using the two-scale relation of B-splines, we introduce a subdivision-stabilization for the two-field mixed MPM and obtain numerically stable, oscillation-free nodal solutions with equal-order interpolations with optimal regularity. Building on the Eulerian-Lagrangian nature of MPM, a previously-converged solution framework is adopted to mitigate issues related to cell-crossing and numerical fracture artifact present in standard MPM. We assess the stability and accuracy of the developed mixed MPM at large deformations for soft materials through the benchmark Cook’s membrane problem. Additionally, we test the robustness of the proposed MPM by modeling several examples, including the compression and indentation of a circular block into a quasi-compressible substrate and the twisting deformation of a rectangular block. The findings demonstrate the MPM’s capabilities for modeling practical soft material applications.

36 MATERIALS SCIENCE↗

Accurate spectroscopic characterization of protonated oxirane: a potential prebiotic species in Titan's atmosphere

An accurate spectroscopic characterization of protonated oxirane has been carried out by means of state-of-the-art computational methods and approaches. The calculated spectroscopic parameters from our recent computational investigation of oxirane together with the corresponding experimental data available were used to assess the accuracy of our predicted rotational and IR spectra of protonated oxirane. We found an accuracy of about 10 cm{sup –1} for vibrational transitions (fundamentals as well as overtones and combination bands) and, in relative terms, of 0.1% for rotational transitions. We are therefore confident that the spectroscopic data provided herein are a valuable support for the detection of protonated oxirane not only in Titan's atmosphere but also in the interstellar medium.

79 ASTRONOMY AND ASTROPHYSICS↗

Faraday detector uranium isotope ratio measurement: Insights from solution- and laser ablation-based sampling methodologies on the Neoma MC-ICP-MS

In this study we utilize an all-faraday cup detector configuration on the Neoma MC-ICP-MS to perform uranium isotope ratio determinations from certified reference materials and a nuclear fuel precursor material via solution and laser ablation based sampling methodologies. The goal in performing these measurements is primarily to demonstrate that the all-faraday cup method can produce highly precise and accurate isotope ratios even at relatively low signal intensity levels while also developing a preliminary understanding of how the complex interplay between different amplifier resistor levels (e.g. 10 11 vs 10 13 Ω) and integration times impacts the precision and accuracy of different types of measurements. Our results show that the faraday cups with 1013 Ω resistors in their amplifier feedback loops can be used to produce accurate and relatively precise isotope ratios for ion beams down to ~5 K cps. However, at the lower end of the signal intensities observed in this study, longer integration times are necessary to mitigate the impact of ion beam instability that can occur during laser ablation based sampling. Despite this potential limitation, the all-faraday cup method is highly versatile as exemplified by the analysis of a collection of uranium reference materials with highly variable uranium isotopic compositions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Empirical validation of building energy simulation model input parameter for multizone commercial building during the cooling season

This paper presents a critical advancement in Building Energy Modeling (BEM) through an empirical validation approach using a high-quality dataset from a multizone commercial office building in Oak Ridge, TN, USA. BEM is widely utilized in diverse construction applications, but its effectiveness relies on the accuracy of its predictions. The study focuses on empirical validation of input parameters in BEM, including building envelope data, infiltration modeling, and rooftop unit system performance curves. The validation of simulation input parameters leads to substantial improvements in the accuracy of simulation results. Notable both NMBE and cv (RMSE) values are reduced by 0.5 % for indoor air temperature and 17 % for indoor air relative humidity compared to the previous model. At the system level, both NMBE and cv (RMSE) values are reduced by 2 % for fan energy consumption and 4 % for cooling energy consumption, compared to the previous model. A literature review highlights a significant gap in empirical validation studies, which predominantly concentrate on either component-level or whole building validation. Furthermore, many studies employ simplified setups that may not faithfully represent the complexities of multizone commercial buildings. This paper distinguishes itself by emphasizing the critical importance of component-level input parameter validation. It underlines the need to validate data related to building envelope components and HVAC system performance curves, resulting in more accurate simulation outcomes. In conclusion, the utilization of actual multizone commercial building data enhances the study's practical relevance. In summary, this research underscores the pivotal role of input parameter validation in enhancing the accuracy and reliability of BEM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MS25: Materials Science-Focused Benchmark Data Set for Machine Learning Interatomic Potentials

Here, we present MS25, a benchmark data set for evaluating machine learning interatomic potentials (MLIPs) across diverse materials-relevant systems including MgO surfaces, liquid water, zeolites, a catalytic Pt surface reaction, high-entropy alloys (HEAs), and disordered Zr-oxides. Five MLIP architectures (MACE, NequIP, Allegro, MTP, and Torch-ANI) are trained and tested, focusing not only on traditional metrics (energies, forces, and stresses) but also explicitly validating derived physical observables such as lattice constants, volumes, and reaction barriers. We find that most models reach comparable accuracy on standard error metrics across the simple systems, although equivariant MLIPs offer 1.5–2× improvements over nonequivariant MLIPs in energy and force error for structurally complex or compositionally disordered environments such as HEAs and Zr–O systems. Our analysis highlights that low errors in energy and force predictions do not guarantee reliable observables, emphasizing the necessity of explicit validation. We demonstrate limitations in cross-framework transferability, as models trained on one zeolite framework (CHA) fail to reliably generalize to predictions of structurally distinct frameworks (e.g., MFI). Size-extensive tests show some dependence on system size for MgO, resulting from forced periodicity. The HEA and Zr–O data sets are identified as challenging tests for future benchmarks and MLIP model architecture developments as they show significant differentiation in error between MLIP architectures and are still relatively difficult at 1000 training images. Moving forward, we recommend that benchmarking efforts shift their focus from marginal accuracy improvements in energy and force errors toward identifying and understanding model failure modes, rigorously assessing transferability, and evaluating how their errors affect observable predictions. For researchers looking to choose an MLIP architecture, we suggest selecting equivariant MLIP architectures if the complexity of the system is a challenge. For simple materials problems, auxiliary features such as integration with molecular dynamics engines, trade-offs between computational data set generation cost vs MLIP inference speed, and framework integration may play a more important decision factor than small differences in error metrics that are unlikely to matter for production-level research.

chemical structure↗

Verification and Validation of the FLAG Hydrocode for Impact Cratering Simulations

Verification and validation (V&V) are necessary processes to ensure accuracy of the computational methods used to solve problems key to vast numbers of applications and industries. Simulations are essential for addressing impact cratering problems, because these problems often exceed experimental capabilities. We show that the free Lagrange (FLAG) hydrocode, developed at Los Alamos National Laboratory (Los Alamos, NM), can be used for impact cratering simulations by verifying FLAG against two analytical models of aluminum-on-aluminum impacts at different impact velocities and validating FLAG against a glass-into-water laboratory impact experiment. Our verification results show good agreement with the theoretical maximum pressures, with relative errors as low in magnitude as 1.00%. Our validation results demonstrate FLAG's ability to model various stages of impact cratering, with crater radius relative errors as low as 3.48% and crater depth relative errors as low as 0.79%. Our mesh resolution study shows that FLAG converges at resolutions low enough to reduce the required computation time from about 28 h to about 25 min. We anticipate that FLAG can be used to model larger impact cratering problems with increased accuracy and decreased computational cost on current systems relative to other hydrocodes tested by Pierazzo et al. (2008, “Validation of Numerical Codes for Impact and Explosion Cratering: Impacts on Strengthless and Metal Targets,” MAPS, 43(12), pp. 1917–1938).

97 MATHEMATICS AND COMPUTING↗

Application of deep neural networks to improve diagnostic accuracy of rheumatoid arthritis using diffuse optical tomography

A set of deep neural network models for rheumatoid arthritis (RA) classification using a highway network, a convolutional neural network and a residual network is proposed based on the data of diffuse optical tomography (DOT) utilising near-infrared light, which ensures early diagnosis of pathophysiological changes resulting from inflammation. A numerical model of the finger is used to generate images to overcome the inherent problem of insufficient clinical DOT images available. The proposed deep neural network models are applied to automatically classify simulated DOT images of inflamed and non-inflamed joints and transfer learning is also used to improve the performance of the classification. The results demonstrate that all three deep neural network methods improve the diagnostic accuracy as compared to the widely applied support vector machine (SVM), especially for high inter-subject variability databases. In cases of distinct modelled severity of disease, residual network achieved the highest accuracy (> 99 %), and both of highway and convolutional neural networks reached 99 %, respectively. However, as the severity of the modelled disease is reduced, this accuracy is reduced to 75.2 % for residual networks. The results indicate that transfer learning can improve the performance of deep neural network methods on RA classification from DOT data and highlight their potential as a computer aided tool in DOT diagnostic systems. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗