Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Systematic study of variation in radiation data in cluttered environments

There are many challenges to overcome during nuclear nonproliferation measurements, including a wide variety of clutter sources that may be introduced into a scene during acquisition. The ability to understand how the dissimilarity of various objects, or clutter, obscures a detector’s field of view and affects the measured response of the detector improves the input to detection alarm and nuclide identification algorithms. Additionally, having the capability to input clutter variation into radiation transport models would allow for more real-world scenarios to be modeled and understood. Efforts at Oak Ridge National Laboratory have been exploring the ability to determine specific natural background radiation contributions from surroundings, such as buildings, soil, asphalt, and concrete, and use those source terms in large-scale (100 + m) models. The capability to quantify different clutter terms, ranging from humans to large vehicles, allows researchers to inject realistic noise into these models. The work reported herein seeks to explore the effects that clutter introduces to quantify the expected signal variation inherent to both controlled and uncontrolled scenarios, specifically how the introduction of clutter into a scene introduces a variation in signals due to the attenuation of naturally occurring radioactive material distributed within the scene or by introducing non-threatening radioactive materials into the scene. Controlled measurements aim to quantify how different types of clutter of varying size and composition affects the response of a radiation detector. Using results from various controlled tests, the systematic effects of clutter and its effect on radiation readings is analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Timing layers, 4- and 5-dimension tracking

The combination of precision space and time information in particle tracking, the so called 4D tracking, is being considered in the upgrade of the ATLAS, CMS and LHCb experiments at the High-Luminosity LHC, set to start data taking in 2024–2025. Regardless of the type of solution chosen, space–time tracking brings benefits to the performance of the detectors by reducing the background and sharpening the resolution; it improves tracking performances and simplifies tracks combinatorics. Space–time tracking also allows investigating new physics channels, for example it opens up the possibilities of new searches in long-living particles by measuring accurately the time of flight between the production and the decay vertexes. The foreseen applications of 4D tracking in experiments with very high acquisition rates, for example at HL-LHC, add one more dimension to the problem, increasing dramatically the complexity of the read-out system and that of the whole detector design: we call 5D tracking the application of 4D tracking in high rate environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interaction position, time, and energy resolution in organic scintillator bars with dual-ended readout

We report on the position, timing, and energy resolution of a range of plastic scintillator bars and reflector treatments using dual-ended silicon photomultiplier readout. These measurements are motivated by the upcoming construction of an optically segmented single-volume neutron scatter camera, in which neutron elastic scattering off of hydrogen is used to kinematically reconstruct the location and energy of a neutron-emitting source. For this application, interaction position resolutions of about 10 mm and timing resolutions of about 1 ns are necessary to achieve the desired efficiency for fission-energy neutrons. The results presented here indicate that this is achievable with an array of 5 x 5 x 190 mm 3 bars of EJ-204 scintillator wrapped in Teflon tape, read out with SensL’s J-series 6 x 6 mm 2 silicon photomultipliers. With two independent setups, we also explore the systematic variability of the position resolution, and show that, in general, using the difference in the pulse arrival time at the two ends is less susceptible to systematic variation than using the log ratio of the charge amplitude of the two ends. Finally, we measure a bias in the absolute time of interactions as a function of position along the bar: the measured interaction time for events at the center of the bar is 100 ps later than interactions near the SiPM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The radioactive source calibration system of the PROSPECT reactor antineutrino detector

The Precision Reactor Oscillation and Spectrum (PROSPECT) Experiment is a reactor neutrino experiment created to search for sterile neutrinos with a mass on the order of 1 eV/c 2 and to measure the spectrum of electron antineutrinos from a highly-enriched 235 U nuclear reactor. The PROSPECT detector consists of an 11 by 14 array of optical segments in 6 Li-loaded liquid scintillator at the High Flux Isotope Reactor in Oak Ridge National Laboratory. Antineutrino events are identified via inverse beta decay and read out by photomultiplier tubes located at the ends of each segment. The detector response is characterized using a radioactive source calibration system. Here, we describe the design, operation, and performance of the PROSPECT source calibration system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extending the dynamic range of electronics in a Time Projection Chamber

When Time Projection Chambers (TPCs) are used in low to intermediate heavy ion collisions, the mass and momentum range of the emitted particles cover a wide range in energy losses. Many TPC readout electronics currently only have a single gain output with a fixed dynamic range. In a recent set of experiments using the SAMURAI Pion-Reconstruction and Ion-Tracker (StrRIT) TPC, it was important to simultaneously measure relativistic pions and heavy ion tracks from the same collisions. As the ionization from a track's energy loss is collected and multiplied by the anode wires, a distribution of image charges is induced on the TPC read-out pads. If the avalanche on a wire is large enough, the charge collected by pads directly underneath will saturate the readout electronics; pads farther away in the distribution will not be saturated. Using these unsaturated pads and the known pad distribution function, we can estimate the charge on saturated pads, increasing the dynamic range by a factor of 5.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact readout of large CLYC scintillators with silicon photomultipler arrays

Compact readout of a large (5 x 5 x 5 cm 3) CLYC scintillator was demonstrated with a 8 x 8 array of 6mm silicon photomultipliers (SiPMs, specifically, a SensL ArrayJ-60035-64P) and an optimized amplification and summing circuit. Read out by the SiPM array, the crystal yielded an energy resolution of 5.5% at 662 keV and a figure of merit of 3.5, equivalent to the performance achieved with a 3-inch Hamamatsu R6233-100 PMT. To reduce channel count and avoid individual amplification of each SiPM in the array, the standard outputs of 16 SiPMs were passively summed then amplified. A current feedback amplifier was used for each channel to provide the required fast response time. The four amplified channels were then passively summed resulting in a single signal channel. A custom laboratory setup, based on the PSD8C ASIC, was used to capture the output and provide time-gated integration for PSD computation. We conclude the compact volume, low bias voltage, and reduced mass of the SiPM array readout are desirable for space and national security applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The small-angle neutron scattering extension in MCNPX and the SANS cross section for nanodiamonds

Detonation nanodiamonds provide an intriguing prospect for the development of a very cold neutron (VCN) source or as a high albedo material for VCN reflection helping to control leakage of cold and very cold neutrons in a moderator. The investigation of source and reflector designs necessitates the development of new simulation tools for existing Monte Carlo codes that include small angle neutron scattering (SANS). The SANS extension in MCNPX 2.7 provides an analytical model of hard-sphere scattering with variable scattering particle sizes, size distributions, and packing fractions in order to supplement currently existing scattering kernels as well as the capability to read an experimentally determined small angle neutron scattering profile from a data file. The SANS extension is discussed and compared to nanodiamond SANS measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 Central Time-of-Flight system

The Central Time-of-Flight system for the large-acceptance CLAS12 spectrometer in Hall B at the Thomas Jefferson National Accelerator Facility is described. The system consists of a hermetic barrel of 48 scintillation counters at a radius of 25 cm from the beamline. The wedge-shaped counters are 3.4 cm wide, 3.0 cm thick, and 90 cm long, and span a range of polar angles relative to the center of the nominal target location from roughly 35° to 125°. The counters reside in the 5-T field of the CLAS12 superconducting solenoid. The bars are read out via bent light guides 1 m long on the upstream end of the counters and 1.6 m long on the downstream end. The phototubes are shielded by a multi-layer dynamical magnetic shield system to reduce the local fringe fields in the range from 400 G to 1000 G down to the level of 0.2 G at the location of the photocathodes. The average effective time resolution of the counters is 80 ps.

47 OTHER INSTRUMENTATION↗

The CLAS12 Silicon Vertex Tracker

Silicon Vertex Tracker (SVT) has been designed for the CLAS12 spectrometer using single-sided microstrip sensors fabricated by Hamamatsu Photonics. The sensors have a graded angle design to minimize dead areas and a readout pitch of 156 um, with intermediate strips. Each double-sided SVT module hosts three daisy-chained sensors on each side with a full strip length of 33 cm. There are 512 channels per module, read out by four Fermilab Silicon Strip Readout (FSSR2) chips, featuring data-driven architecture, mounted on a rigid–flex hybrid board. The modules are assembled in a barrel configuration using a unique cantilevered geometry to minimize the amount of material in the tracking volume. This paper is focused on the design, qualification of the performance, and experience in operating and commissioning the tracker during the first year of the data taking.

47 OTHER INSTRUMENTATION↗

Performance of 8 × 8 × 32 and 10 × 10 × 32 mm 3 CdZnTe position-sensitive virtual Frisch-grid detectors for high-energy gamma ray cameras

CdZnTe (CZT) crystals with thicknesses up to 20 mm and diameters up to 75 mm have become available from Redlen Technologies, Inc. for making large-volume gamma-ray detectors. The modified growth and optimized annealing conditions allowed Redlen to minimize the dark current and improve the uniformity of CZT crystals. Two detector designs, pixelated (H3D) and position-sensitive virtual Frisch-grid (VFG), have greatly benefitted from the availability of such big crystals. Encouraging results from testing of 40×40×15 mm 3 pixelated detectors were recently reported by the University of Michigan. In this work, we evaluated the spectroscopic properties of 8×8×32 and 10×10×32 mm 3 crystals configured as position-sensitive VFG detectors. Both digitized waveforms and an analog ASIC were used to read and process the signals from the detectors and test their spectral- and spatial-resolution. The VFG design provides the flexibility to scale-up the dimensions of the detectors for the desired efficiency, while the position information allows for correcting the detectors' response non-uniformity caused by crystal defects and devices geometry, thereby reducing the instrument cost and making them more feasible for emerging applications in gamma-ray astronomy, nonproliferation, portal screening and nuclear safeguards, where large detector arrays are often required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plastic scintillation detectors for time-of-flight mass measurements

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting Cyclotron Laboratory (NSCL) by increasing the number of photomultiplier tubes that read out their light signals to four per detector, and characterized them in a test experiment with 48 Ca beam at the NSCL. The new detectors achieved a time resolution (σ) of 7.5 ps. We systematically investigated different factors that affect their timing performance. In addition, we evaluated the ability of positioning the hitting points on the scintillator using the timing information and obtained a resolution (σ) below 1 mm for well-defined beam spots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 Backward Angle Neutron Detector (BAND)

The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of 155° to 175°, with momenta between 200 and 600 MeV$/c_0$. It is positioned 3-m upstream of the target, consists of 18 rows and 5 layers of 7.2-cm by 7.2-cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2-cm thick lead wall followed by a 2-cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than 250 ps (150 ps) for energy depositions above 2 MeV (5 MeV). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. We report the time resolution results in a neutron momentum reconstruction resolution, $δp/p$ < 1.5% for neutron momentum 200 ≤ $p$ ≤ 600 MeV/c. Final performance of the BAND with CLAS12 is shown, including electron–neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Event reconstruction in a liquid xenon Time Projection Chamber with an optically-open field cage

nEXO is a proposed tonne-scale neutrinoless double beta decay (0νββ) experiment using liquid 136 Xe (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe (“skin” LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. Here, in this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the γ-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Then, background from 222 Rn dissolved in the skin LXe can be efficiently rejected by tagging the α decay in the 214 Bi- 214 Po chain in the skin LXe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 90 ° bend curved light-guide for TOF scintillating detectors

We report here a bench study of TOF resolution using a 90° bend curved solid light-guide (LG) used to transport the light from a plastic scintillator counter to a photomultiplier (PMT). The 90° LG allows the rotation of the PMT axis to be vertical to the detector axis, in an environment featured by a strong magnetic field along the detector surface, or other geometrical constrains. We show that with a TOF counter of 2000 x 100 x 60 mm 3 and light read-out by PMTs at its two 100 × 60 mm 2 sides, when 90° LG benders are used between the scintillating bar and the PMTs on both sides, the TOF resolution is worsen, by 5–10%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Convolution-based frequency domain multiplexing of SiPM readouts using the $\mathrm{DRS4}$ digitizer

Here we present 4:1 multiplexing of organic scintillators, each coupled to a silicon photomultiplier (SiPM), to reduce the need for a large number of digitizer input channels to readout highly pixelated radiation detection systems. Frequency domain multiplexing (FDM) encodes a detector pulse by assigning it a unique frequency via convolution before combining the encoded signal into a single channel. The combined signal is then read through a digitizer input channel. We have designed an FDM system to multiplex four SiPMs using DRS4 digitizer evaluation board from Paul Scherrer Institute (PSI). We demonstrate 4:1 multiplexing of the SiPM fast output signals and pulse recovery from the digitized multiplexed signal using deconvolution. The noise in the recovered pulse introduces a bias and uncertainty in the estimate of energy and timing that changes with pulse height. The relative uncertainty in the estimated energy from the recovered pulse decreases with pulse height with a maximum uncertainty of 3.1% for the low energy pulses (corresponding to 100 keV); the uncertainty in the estimated time pick-off also decreases with pulse height with a maximum uncertainty of 110 ps for the low energy pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BoxScore - A real-time beam-diagnosis program for the CAEN digitizer x730 series

BoxScore is a real-time beam diagnosis and monitoring program for the CAEN x730 series digitizer, developed for the ATLAS in-flight system at Argonne National Laboratory. The CAEN x730 series digitizer, with built-in Digital Pulse Processing for the Pulse-Height-Analysis, digitizes the input signal in real-time and processes it using a trapezoidal filter. BoxScore reads the digitizer’s buffer directly, builds and saves events to local files, plots histograms for particle identification, and outputs the rates of selected isotopes every second. Implementation of BoxScore has shortened the time needed for in-flight beam-tuning and has potential applications for other nuclear physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of signal characteristics and charge sharing in AC-LGADs with laser and test beam measurements

AC-LGADs, also referred to as resistive silicon detectors, are a recent development of low-gain avalanche detectors (LGADs), based on a sensor design where the multiplication layer and n + contact are continuous, and only the metal layer is patterned. In AC-LGADs, the signal is capacitively coupled from the continuous, resistive n + layer over a dielectric to the metal electrodes. Therefore, the spatial resolution is not only influenced by the electrode pitch, but also the relative size of the metal electrodes. Signal propagation between the metallized areas and charge sharing between electrodes plays a larger role in these detectors than in conventional silicon sensors read out in DC mode. AC-LGADs from two manufacturers were studied in beam tests and with infrared laser scans. The impact of n + layer resistivity and metal electrode pitch on the charge sharing and achievable position resolution is shown. For strips with 100 μm pitch, a resolution of ¡ 5 μm can be reached. Additionally, the charge sharing between neighboring strips is investigated in more detail, indicating the induction of signal charge and subsequent re-sharing over the n + layer. Furthermore, an approach to identify signal sharing over large distances is presented.

47 OTHER INSTRUMENTATION↗