Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

CHANDRA DISCOVERY OF A BINARY ACTIVE GALACTIC NUCLEUS IN Mrk 739

We have discovered a binary active galactic nucleus (AGN) in the galaxy Mrk 739 using Chandra and Swift BAT. We find two luminous (L{sub 2-10 keV} = 1.1 x 10{sup 43} and 1.0 x 10{sup 42} erg s{sup -1}), unresolved nuclei with a projected separation of 3.4 kpc (5.''8 {+-} 0.''1) coincident with two bulge components in the optical image. The western X-ray source (Mrk 739W) is highly variable (x 2.5) during the 4 hr Chandra observation and has a very hard spectrum consistent with an AGN. While the eastern component was already known to be an AGN based on the presence of broad optical recombination lines, Mrk 739W shows no evidence of being an AGN in optical, UV, and radio observations, suggesting the critical importance of high spatial resolution hard X-ray observations (>2 keV) in finding these binary AGNs. A high level of star formation combined with a very low L{sub [O{sub III}]/L{sub 2-10 keV}} ratio cause the AGN to be missed in optical observations. {sup 12}CO observations of the (3-2) and (2-1) lines indicate large amounts of molecular gas in the system that could be driven toward the black holes during the violent galaxy collision and be key to fueling the binary AGN. Mrk 739E has a high Eddington ratio of 0.71 and a small black hole (log M{sub BH} = 7.05 {+-} 0.3) consistent with an efficiently accreting AGN. Other than NGC 6240, this stands as the nearest case of a binary AGN discovered to date.

79 ASTRONOMY AND ASTROPHYSICS↗

Off-axis viewing of radiation emission by long wiggler sources

When high-brilliance radiation is needed for experiments, insertion device sources are generally viewed on-axis. Off-axis emission of flux can be prodigious especially from wiggler sources having large emission fans. The on-axis and off-axis radiation emission characteristics from insertion device sources have been calculated extensively and are well known, but experimental verifications of some characteristics, particularly those associated with off-axis emission, are relatively few. Here measurements of the flux spectrum and apparent source size are described, as a function of horizontal emission angle, from the former X25 hybrid wiggler at the National Synchrotron Light Source (NSLS).

36 MATERIALS SCIENCE↗

Second-Harmonic Generation of Subterahertz Gyrotron Radiation by Frequency Doubling in InP:Fe and Its Application for Magnetospectroscopy of Semiconductor Structures

The possibility of obtaining intense terahertz radiation due to second-order lattice nonlinearity in indium-phosphide crystals doped with iron is discussed. As a source of radiation, subterahertz gyrotrons are considered. It is shown that the efficiency of frequency doubling can reach 3%, which opens up the possibility for developing a new generation of terahertz radiation sources. The possibility of applying second-harmonic radiation for the magnetospectroscopy of semiconductor structures with quasi-Dirac dispersion is demonstrated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Compact sources of EUV radiation

Contrary to classical theoretical expectations extreme ultraviolet emissions from a number of stellar objects have been recently discovered. A combined EUV and optical study of these sources has revealed a wealth of new information on stellar structure and evolution especially for what regards the transition stage between planetary nebulae and white dwarfs. The current status of research in this field is reviewed with emphasis on the impact these observations are having on our view of the later stages of stellar evolution and on the future possibility that could be awaiting a sensitive all sky survey of the EUV spectrum.

Paresce, F.↗

Correction of Spherical Aberration in Grazing-Incidence X-ray Optics by Combination of Spherical-Concave Mirrors

In grazing-incidence total-reflection mirror optics for x-rays, spherical aberrations and coma are the most serious aberrations for microfocusing and microimaging. High-resolution imaging is believed to be possible only when an aspherical mirror system is used. However, the spherical aberrations of a spherical-concave mirror in a grazing-incidence condition can be eliminated by sequential reflection of spherical mirrors of similar shapes. A sub-micrometer one-dimensional focusing is easily achieved by the spherical-aberration-corrected tandem-spherical mirror optics. By configuring four spherical mirrors in an analogy of the crossed mirror optics (Kirkpatrick-Baez optics), it is possible to achieve sub-micrometer focused beam size in the hard x-ray region. Preliminary experiments on x-ray microfocusing have been carried out at beamline 20XU of SPring-8, and a 0.5 {mu}mx0.4 {mu}m beam size was achieved at 8 keV.

07 ISOTOPE AND RADIATION SOURCES↗

Superconducting source for tunable coherent terahertz radiation

A system includes a solid state source of THz radiation and a detector. The source of THz radiation may be based on a superconducting material, such as materials containing one or more Josephson junctions (e.g. BSCCO). The source may include a crystal of superconducting material on which a mesa of superconducting material is formed. The resonant coupling between the Josephson oscillations and the fundamental cavity mode of the mesa may lead to synchronization of the Josephson junctions and emission of powerful THz radiation. The mesa may be formed and/or handled such that THz radiation can be emitted by the material without requiring application of an external magnetic field (e.g. the mesa may include a non-uniform compositional gradient, a non-uniform shape, may have radiation non-uniformly applied to the mesa, etc.).

Koshelev, Alexei E.↗

Two Sources of Nonisotropic Radiation From Underground Explosions in Granite

Significant tangential ground motion observed during underground explosions makes it difficult to distinguish them from natural earthquakes. Such motion can be generated by the source geometry and emplacement conditions, by the heterogeneous nature of the rock mass (mechanical properties may vary in space due to the presence of cracks, joints, faults, and various geologic layers) and also by the nonuniform in situ stress state. The last mechanism is increasingly important with depth when the difference in main principal stresses becomes significant. This paper is focused on the role of material strength of the rock mass in generation of nonradial motion during explosions in prestressed media. Numerical modeling of underground chemical explosions in granite at various depths has been conducted to compare two possible mechanisms of shear wave generation. The first, caused by rock mass anisotropy, is important at shallow depth. The second is related to elastic-plastic relaxation around the cavity created by the explosion. As a result, tangential motions for these two mechanisms have different signatures.

54 ENVIRONMENTAL SCIENCES↗

Source size measurement options for low-emittance light sources

Radiation-based techniques for measuring electron source sizes are widely used as emittance diagnostics at existing synchrotron sources. Three of these techniques, namely, pinhole imaging, double-slit interferometry, and a K-edge filter-based beam position and size monitor system (ps-BPM), are evaluated for measuring source sizes at low-emittance storage rings. Each technique is reviewed with a detailed system description, design optimization, and practical considerations targeted for small source sizes. Pinhole imaging has the simplest setup and gives the beam profile in both transverse dimensions but with limited resolution. Double-slit interferometry has the highest resolution but with a limited detectable size range. The ps-BPM system shows reasonable resolution for monitoring small source sizes and divergence and can give real-time information of the source position and angle. New facilities may consider an integrated system that combines some or all of these techniques.

43 PARTICLE ACCELERATORS↗

Imaging of cochlear tissue with a grating interferometer and hard X-rays

This article addresses an important current development in medical and biological imaging: the possibility of imaging soft tissue at resolutions in the micron range using hard X-rays. Challenging environments, including the cochlea, require the imaging of soft tissue structure surrounded by bone. We demonstrate that cochlear soft tissue structures can be imaged with hard X-ray phase contrast. Furthermore, we show that only a thin slice of the tissue is required to introduce a large phase shift. It is likely that the phase contrast image of the soft tissue structures is sufficient to image the structures even if surrounded by bone. For the present set of experiments, structures with low-absorption contrast have been visualized using in-line phase contrast imaging and a grating interferometer. The experiments have been performed at the Advanced Photon Source at Argonne National Laboratories, a third generation source of synchrotron radiation. The source provides highly coherent X-ray radiation with high-photon flux (>10{sup 12} photons/s) at high-photon energies (5-70 keV). Radiographic and light microscopy images of the gerbil cochlear slice samples were compared. It has been determined that a 20-{micro}m thick tissue slice induces a phase shift between 1/3{pi} and 2/3{pi}.

43 PARTICLE ACCELERATORS↗

Dose Escalation to the Dominant Intraprostatic Lesion Defined by Sextant Biopsy in a Permanent Prostate I-125 Implant: A Prospective Comparative Toxicity Analysis

Purpose: Using real-time intraoperative inverse-planned permanent seed prostate implant (RTIOP/PSI), multiple core biopsy maps, and three-dimensional ultrasound guidance, we planned a boost volume (BV) within the prostate to which hyperdosage was delivered selectively. The aim of this study was to investigate the potential negative effects of such a procedure. Methods and Materials: Patients treated with RTIOP/PSI for localized prostate cancer with topographic biopsy results received an intraprostatic boost (boost group [BG]). They were compared with patients treated with a standard plan (reference group [RG]). Plans were generated using a simulated annealing inverse planning algorithm. Prospectively recorded urinary, rectal, and sexual toxicities and dosimetric parameters were compared between groups. Results: The study included 120 patients treated with boost technique who were compared with 70 patients treated with a standard plan. Boost technique did not significantly change the number of seeds (55.1/RG vs. 53.6/BG). The intraoperative prostate V150 was slightly higher in BG (75.2/RG vs. 77.2/BG, p = 0.039). Urethra V100, urethra D90, and rectal D50 were significantly lower in the BG. No significant differences were seen in acute or late urinary, rectal, or sexual toxicities. Conclusions: Because there were no differences between the groups in acute and late toxicities, we believe that BV can be planned and delivered to the dominant intraprostatic lesion without increasing toxicity. It is too soon to say whether a boost technique will ultimately increase local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Dose-Volume Analysis of Magnetic Resonance Imaging-Aided High-Dose-Rate Image-Based Interstitial Brachytherapy for Uterine Cervical Cancer

Purpose: To investigate the feasibility of our novel image-based high-dose-rate interstitial brachytherapy (HDR-ISBT) for uterine cervical cancer, we evaluated the dose-volume histogram (DVH) according to the recommendations of the Gynecological GEC-ESTRO Working Group for image-based intracavitary brachytherapy (ICBT). Methods and Materials: Between June 2005 and June 2007, 18 previously untreated cervical cancer patients were enrolled. We implanted magnetic resonance imaging (MRI)-available plastic applicators by our unique ambulatory technique. Total treatment doses were 30-36 Gy (6 Gy per fraction) combined with external beam radiotherapy (EBRT). Treatment plans were created based on planning computed tomography with MRI as a reference. DVHs of the high-risk clinical target volume (HR CTV), intermediate-risk CTV (IR CTV), and the bladder and rectum were calculated. Dose values were biologically normalized to equivalent doses in 2-Gy fractions (EQD{sub 2}). Results: The median D90 (HR CTV) and D90 (IR CTV) per fraction were 6.8 Gy (range, 5.5-7.5) and 5.4 Gy (range, 4.2-6.3), respectively. The median V100 (HR CTV) and V100 (IR CTV) were 98.4% (range, 83-100) and 81.8% (range, 64-93.8), respectively. When the dose of EBRT was added, the median D90 and D100 of HR CTV were 80.6 Gy (range, 65.5-96.6) and 62.4 Gy (range, 49-83.2). The D{sub 2cc} of the bladder was 62 Gy (range, 51.4-89) and of the rectum was 65.9 Gy (range, 48.9-76). Conclusions: Although the targets were advanced and difficult to treat effectively by ICBT, MRI-aided image-based ISBT showed favorable results for CTV and organs at risk compared with previously reported image-based ICBT results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Clinical Experience With the Strut-Adjusted Volume Implant (SAVI) Breast Brachytherapy Device for Accelerated Partial-Breast Irradiation (APBI): First 100 Patients With More Than 1 Year of Follow-Up

Purpose: The Strut-Adjusted Volume Implant (SAVI; Cianna Medical, Aliso Viejo, CA) is a multichannel single-entry brachytherapy device designed to allow dose modulation to minimize normal tissue dose while simultaneously maximizing target coverage. This is the first report on the initial 102 patients with nearly 2 years of median follow-up. Methods and Materials: One hundred two patients were treated at two institutions. Data were collected on eligibility and dosimetry and followed for toxicity and recurrence. Results: The median follow-up is 21 months. Overall dosimetry is outstanding (median percent of target volume receiving 90% of the prescription dose was 95.9%, volume of target receiving 150% of the prescription dose was 27.8 mL, and volume of target receiving 200% of the prescription dose was 14.0 cm{sup 3}). No devices were pulled prior to treatment completion. For patients with a skin bridge of less than 7 mm, the maximum median skin dose was 280 cGy (median percent of target volume receiving 90% of the prescription dose was 95.2%, volume of target receiving 150% of the prescription dose was 25.8 cm{sup 3} and volume of target receiving 200% of the prescription dose was 12.7 mL). For patients with both chest wall and skin of less than 7 mm, the maximum median lung dose was 205 cGy with simultaneous skin dose of 272 cGy. The rate of telangiectasia was 1.9%. Grade 1 hyperpigmentation developed in 10 patients (9.8%) and Grade 2 fibrosis in 2 patients (1.9%). There were 2 symptomatic seromas and 2 cases of asymptomatic fat necrosis (1.9%). Of the patients, 27% were not eligible for MammoSite balloon brachytherapy (Hologic, Inc., Marlborough, MA) and 5% were not eligible for any balloon brachytherapy. The recurrence rate was 1%. Conclusions: The SAVI appears to safely allow an increase in eligibility for APBI over balloon brachytherapy or three-dimensional conformal radiation, highlighting the outstanding device flexibility to maximize the target dose and minimize the normal tissue dose. The device was well tolerated by patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerated Partial Breast Irradiation With Interstitial Implants: Risk Factors Associated With Increased Local Recurrence

Purpose: To analyze patient, disease, and treatment-related factors regarding their impact on local control after interstitial multicatheter accelerated partial breast irradiation (APBI). Methods and Materials: Between November 2000 and April 2005, 274 patients with early breast cancer were recruited for the German-Austrian APBI Phase II trial ( (ClinicalTrials.gov) identifier: NCT00392184). In all, 64% (175/274) of the patients received pulsed-dose-rate (PDR) brachytherapy and 36% (99/274) received high-dose-rate (HDR) brachytherapy. Prescribed reference dose for HDR brachytherapy was 32 Gy in eight fractions of 4 Gy, twice daily. Prescribed reference dose in PDR brachytherapy was 49.8 Gy in 83 consecutive fractions of 0.6 Gy each hour. Total treatment time was 3 to 4 days. Results: The median follow-up time was 64 months (range, 9-110). The actuarial 5-year local recurrence free survival rate (5-year LRFS) was 97.7%. Comparing patients with an age <50 years (49/274) vs. {>=}50 years (225/274), the 5-year LRFS resulted in 92.5% and 98.9% (exact p = 0.030; 99% confidence interval, 0.029-0.032), respectively. Antihormonal treatment (AHT) was not applied in 9% (24/274) of the study population. The 5-year LRFS was 99% and 84.9% (exact p = 0.0087; 99% confidence interval, 0.0079-0.0094) in favor of the patients who received AHT. Lobular histology (45/274) was not associated with worse local control compared with all other histologies (229/274). The 5-year LRFS rates were 97.6% and 97.8%, respectively. Conclusions: Local control at 5 years is excellent and comparable to therapeutic successes reported from corresponding whole-breast irradiation trials. Our data indicate that patients <50 years of age ought to be excluded from APBI protocols, and that patients with hormone-sensitive breast cancer should definitely receive adjuvant AHT when interstitial multicatheter APBI is performed. Lobular histology need not be an exclusion criterion for future APBI trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Health-Related Quality of Life After Single-Fraction High-Dose-Rate Brachytherapy and Hypofractionated External Beam Radiotherapy for Prostate Cancer

Purpose: To investigate the change in health-related quality of life for men after high-dose-rate brachytherapy and external beam radiotherapy for prostate cancer and the factors associated with this change. Methods and Materials: Eligible patients had clinically localized intermediate-risk prostate cancer. The patients received high-dose-rate brachytherapy as a single 15-Gy implant, followed by external beam radiotherapy to 37.5 Gy in 15 fractions. The patients were monitored prospectively for toxicity (Common Terminology Criteria for Adverse Events, version 3.0) and health-related quality of life (Expanded Prostate Cancer Index Composite [EPIC]). The proportion of patients developing a clinically significant difference in the EPIC domain score (minimally important difference of >0.5 standard deviation) was determined and correlated with the baseline clinical and dosimetric factors. The study accrued 125 patients, with a median follow-up of 24 months. Results: By 24 months, 23% had Grade 2 urinary toxicity and only 5% had Grade 2 bowel toxicity, with no Grade 3 toxicity. The proportion of patients reporting a significant decrease in EPIC urinary, bowel, sexual, and hormonal domain scores was 53%, 51%, 45%, and 40% at 12 months and 57%, 65%, 51%, and 30% at 24 months, respectively. The proportion with a >1 standard deviation decrease in the EPIC urinary, bowel, sexual, and hormonal domain scores was 38%, 36%, 24%, and 20% at 12 months and 46%, 48%, 19%, and 8% at 24 months, respectively. On multivariate analysis, the dose to 10% of the urethra was associated with a decreasing EPIC urinary domain score (p = .0089) and, less strongly (p = .0312) with a decreasing hormonal domain score. No association was found between the prostate volume, bladder dose, or high-dose volume and urinary health-related quality of life. A high baseline International Index of Erectile Function score was associated (p = .0019) with a decreasing sexual domain score. The optimal maximal dose to 10% of the urethra cutpoint for urinary health-related quality of life was 120% of the prescription dose. Conclusion: EPIC was a more sensitive tool for detecting the effects on function and bother than were the generic toxicity scales. The urethral dose had the strongest association with a deteriorating urinary quality of life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fifteen-Year Biochemical Relapse-Free Survival, Cause-Specific Survival, and Overall Survival Following I{sup 125} Prostate Brachytherapy in Clinically Localized Prostate Cancer: Seattle Experience

Purpose: To report 15-year biochemical relapse-free survival (BRFS), cause-specific survival (CSS), and overall survival (OS) outcomes of patients treated with I{sup 125} brachytherapy monotherapy for clinically localized prostate cancer early in the Seattle experience. Methods and Materials: Two hundred fifteen patients with clinically localized prostate cancer were consecutively treated from 1988 to 1992 with I{sup 125} monotherapy. They were prospectively followed as a tight cohort. They were evaluated for BRFS, CSS, and OS. Multivariate analysis was used to evaluate outcomes by pretreatment clinical prognostic factors. BRFS was analyzed by the Phoenix (nadir + 2 ng/mL) definition. CSS and OS were evaluated by chart review, death certificates, and referring physician follow-up notes. Gleason scoring was performed by general pathologists at a community hospital in Seattle. Time to biochemical failure (BF) was calculated and compared by Kaplan-Meier plots. Results: Fifteen-year BRFS for the entire cohort was 80.4%. BRFS by D'Amico risk group classification cohort analysis was 85.9%, 79.9%, and 62.2% for low, intermediate, and high-risk patients, respectively. Follow-up ranged from 3.6 to 18.4 years; median follow-up was 15.4 years for biochemically free of disease patients. Overall median follow-up was 11.7 years. The median time to BF in those who failed was 5.1 years. CSS was 84%. OS was 37.1%. Average age at time of treatment was 70 years. There was no significant difference in BRFS between low and intermediate risk groups. Conclusion: I{sup 125} monotherapy results in excellent 15-year BRFS and CSS, especially when taking into account the era of treatment effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors of Urinary Morbidity in Cs-131 Prostate Brachytherapy Implants

Purpose: Cesium-131 is a newer radioisotope being used in prostate brachytherapy (PB). This study was conducted to determine the predictors of urinary morbidity with Cs-131 PB. Methods and Materials: A cohort of 159 patients underwent PB with Cs-131 at our institution and were followed by using Expanded Prostate Cancer Index Composite (EPIC) surveys to determine urinary morbidity over time. EPIC scores were obtained preoperatively and postoperatively at 2 and 4 weeks, and 3 and 6 months. Different factors were evaluated to determine their individual effect on urinary morbidity, including patient characteristics, disease characteristics, treatment, and dosimetry. Multivariate analysis of covariance was carried out to identify baseline determinants affecting urinary morbidity. Factors contributing to the need for postoperative catheterization were also studied and reported. Results: At 2 weeks, patient age, dose to 90% of the organ (D90), bladder neck maximum dose (D{sub max}), and external beam radiation therapy (EBRT) predicted for worse function. At 4 weeks, age and EBRT continued to predict for worse function. At the 3-month mark, better preoperative urinary function, preoperative alpha blockers, bladder neck D{sub max}, and EBRT predicted for worse urinary morbidity. At 6 months, better preoperative urinary function, preoperative alpha blockers, bladder neck D{sub max}, and EBRT were predictive of increased urinary problems. High bladder neck D{sub max} and poor preoperative urinary function predicted for the need for catheterization. Conclusions: The use of EBRT plus Cs-131 PB predicts for worse urinary toxicity at all time points studied. Patients should be cautioned about this. Age was a consistent predictor of worsened morbidity immediately following Cs-131 PB, while bladder D{sub max} was the only consistent dosimetric predictor. Paradoxically, patients with better preoperative urinary function had worse urinary morbidity at 3 and 6 months, consistent with recently published literature.

62 RADIOLOGY AND NUCLEAR MEDICINE↗