Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Partial-wave projection of the one-particle exchange in three-body scattering amplitudes

As the study of three-hadron physics from lattice QCD matures, it is necessary to develop proper analysis tools in order to reliably study a variety of phenomena, including resonance spectroscopy and nuclear structure. Reconstructing the three-particle scattering amplitude requires solving integral equations, which can be written in terms of data-constrained dynamical functions and physical on shell quantities. The driving term in these equations is the so-called one-particle exchange, which leads to a kinematic divergence for particles on mass shell. A vital component in defining three-particle amplitudes with definite parity and total angular momentum, which are used in spectroscopic studies, is to project the one-particle exchange into definite partial waves. We present a general procedure to construct exact analytic partial-wave projections of the one-particle exchange contribution for any system composed of three spinless hadrons. Our result allows one full control over the analytic structure of the projection, which we explore for some low-lying partial waves with applications to three pions. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hierarchical Bayesian Thermonuclear Rate for the 7 Be(n,p) 7 Li Big Bang Nucleosynthesis Reaction

Big Bang nucleosynthesis provides the earliest probe of standard model physics, at a time when the universe was less than 1000 seconds old. It determines the abundances of the lightest nuclides, which give rise to the subsequent history of the visible matter in the universe. This work derives new 7 Be(n,p) 7 Li thermonuclear reaction rates based on all available experimental information. This reaction sensitively impacts the primordial abundances of 7 Be and 7 Li during big bang nucleosynthesis. We critically evaluate all available data and disregard experimental results that are questionable. For the nuclear model, we adopt an incoherent sum of single-level, two-channel, R -matrix approximation expressions, which are implemented into a hierarchical Bayesian model, to analyze the remaining six data sets we deem most reliable. In the fitting of the data, we consistently model all known sources of uncertainty, including discrepant absolute normalizations of different data sets, and also take the variation of the neutron and proton channel radii into account, hence providing less biased estimates of the 7 Be(n,p) 7 Li thermonuclear rates. From the resulting posteriors, we extract R -matrix parameters ($E_r, γ^2_n, γ^2_p$) and derive excitation energies and partial and total widths. Our fit is sensitive to the contributions of the first three levels above the neutron threshold. Reaction rates were computed by integrating 10,000 samples of the reduced cross section. Our 7 Be(n,p) 7 Li thermonuclear rates have uncertainties between 1.5% and 2.0% at temperatures of ≤1 GK. Finally, we compare our rates to previous results and find that the 7 Be(n,p) 7 Li rates most commonly used in big bang simulations have uncertainties that are too optimistic.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of octupole collectivity near the A = 72 shape-transitional point

Enhanced octupole collectivity is expected in the neutron-deficient Ge, Se and Kr isotopes with neutron number N ≈ 40 and has indeed been observed for 70,72 Ge. Shape coexistence and configuration mixing are, however, a notorious challenge for theoretical models trying to reliably predict octupole collectivity in this mass region, which is known to feature rapid shape changes with changing nucleon number and spin of the system. To further investigate the microscopic configurations causing the prolate-oblate-triaxial shape transition at A ≈ 72 and their influence on octupole collectivity, the rare isotopes 72 Se and 74,76 Kr were studied via inelastic proton scattering in inverse kinematics. While significantly enhanced octupole strength of ≈32 Weisskopf units (W.u.) was observed for 72 Se, only strengths of ≈15 W.u. were observed for 74,76 Kr. In combination with existing data, the new data clearly question a simple origin of enhanced octupole strengths around N = 40. Furthermore, the present work establishes two regions of distinct octupole strengths with a sudden strength increase around the A = 72 shape transitional point.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AN Tank Farm Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster at the Hanford AN tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from September 30−October 2, 2016, on a slipstream from the AN Exhauster under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Use of Human Modeling of EVA Tasks as a Systems Engineering Tool

Computer-generated human models have been used in aerospace design for a decade. They have come to be highly reliable for worksite analysis of certain types of EVA tasks. In many design environments, this analysis comes after the structural design is largely complete. However, the use of these models as a development tool is gaining acceptance within organizations that practice good systems engineering processes. The design of the United States Propulsion Module for the International Space Station provides an example of this application. The Propulsion Module will provide augmentation to the propulsion capability supplied by the Russian Service Module Zvezda. It is a late addition to the set of modules provided by the United States to the ISS Program, and as a result, faces design challenges that result from the level of immaturity of its integration into the Station. Among these are heat dissipation and physical envelopes. Since the rest of the Station was designed to maximize the use of the cooling system, little margin is available for the addition of another module. The Propulsion Module will attach at the forward end of the Station, and will be between the Orbiter and the rest of ISS. Since cargo must be removed from the Payload Bay and transferred to Station by the Canadarm, there is a potential for protrusions from the module, such as thruster booms, to interfere with robotic operations. These and similar engineering issues must be addressed as part of the development. In the implementation of good system design, all design solutions should be analyzed for compatibility with all affected subsystems. Human modeling has been used in this project to provide rapid input to system trades of design concepts. For example, the placement of radiators and avionics components for optimization of heat dissipation had to be examined for feasibility of EVA translation paths and worksite development. Likewise, the location of and mechanism for the retraction of thruster booms was partly driven by available Orbiter, robotic arm, and other module envelopes; worksite analysis was required for early assessment of task success. Since these trade studies included the EVA analysis as part of the decision criteria, the design had a high degree of assurance of EVA supportability from the outset. This approach contributes greatly to mission success.

Dischinger, H. Charles, Jr.↗

Analysis of Respirator Cartridge Performance Testing on a Hanford Tank SY-102

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors emanating from the headspace of tank SY-102 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, worker breathing rate, and cartridge adsorption capacity. Testing was conducted from July 8–10, 2016, on headspace vapors from Hanford tank SY-102 under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ primary exhauster for the Hanford AY/AZ tank farms. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from August 26–28, 2016, on a slipstream from the 702-AZ exhauster, under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1(SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and change-out frequency.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms during a Waste-Disturbing Event

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ Primary Exhauster for the Hanford AY-AZ tank farms. Unlike prior cartridge testing on the 702-AZ Primary Exhauster, the recent tests were performed during a waste-disturbing event. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from February 10–11, 2017, on a slipstream from the 702-AZ exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) and canisters (e.g., Summa) sampling were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Polarimetric sensitivity of light-absorbing carbonaceous aerosols over ocean: A theoretical assessment

Visible-light-absorbing carbonaceous aerosols within the boundary layer affect the radiance and polarization states of the radiation at the top of the atmosphere. Remote sensing from suborbital and satellite-based platforms utilizes these radiance and polarization signals to retrieve the key properties of these aerosols. Recent retrieval algorithms have shown a progressive trend toward including multi-angular and multi-spectral polarimetric measurements to produce better retrieval accuracy in comparison to those using measurements based on a single viewing angle. Here, we perform a theoretical investigation of the top of atmosphere (TOA) radiance-related reflectance factor (bidirectional reflectance factor (BRF)) and the two types of polarimetry-related factors (polarized bidirectional reflectance factor (pBRF) and the degree of linear polarization (DoLP)) for different types of atmospheric light-absorbing carbonaceous aerosols as a function of particle size distribution. We selected three polarimetric bands corresponding to those utilized by NASA's Airborne Multiangle SpectroPolarimetric Imager (AirMSPI)—near-UV (470 nm), visible (660 nm), and near-infrared (865 nm)—for our simulations which were performed over ocean surface using the successive order of scattering (SOS) algorithm coupled to a Lorenz-Mie aerosol optics model. The analysis of particle phase matrix elements indicates a close relationship between the angular dependencies of DoLP and associated phase matrix components at the shortest polarimetric band (470 nm). Using Jacobian analysis, we find that the radiance- and polarimetry-related reflectance factors of weakly light-absorbing aerosols, such as brown carbon, are more sensitive to changes in particle size and imaginary refractive index in comparison with those of black carbon, which is strongly light-absorbing. Our results suggest that the DoLP data could be used by future retrieval algorithms for reliably estimating microphysical properties of absorbing carbonaceous aerosols with imaginary refractive index less than 0.4.

refractive index↗

Imaging spectrophotometry of the nuclear outflow of NGC 1068

This observational program (in conjunction with R. B. Tully (IfA, Honolulu), and J. Bland (Rice U., Houston)) aims to constrain the kinematic organization and dominant excitation mechanisms of ionized gas in active galaxies. More generally, researchers are interested in the dynamics of radiative, supersonic flows in the Interstellar Medium (ISM). Imaging Fabry-Perot interferometers and low-noise Charge Coupled Devices (CCDs) are used for complete spatial coverage of the complex gas distribution in circumnuclear narrow-line regions (NLRs). Extranuclear emission line widths in NLRs can exceed 3000 km s(-1), so to avoid inter-order confusion researchers use an etalon of 4000 km s(-1) free spectral range to map (N II) lambda lambda 6548, 6583 and H alpha. To maximize spatial resolution, researchers select nearby active systems independent of luminosity but known to possess interesting morphologies and/or high-velocity extranuclear ionized gas. Monochromatic images Full Width Half Maximum (FWHM) approx. 65 km s(-1) have thus far been obtained in 1 second or better seeing at the U. Hawaii 2.2m, CFH 3.6m, and CTIO 4.0m telescopes. These are stacked into grids of line profiles, of spectrophotometric quality, at sub-arcsecond increments across a 3 second field. To handle the approx. 20,000 to 300,000 useful spectra that arise from a typical night's work, researchers have developed a complete analysis and reduction package for VAX and Sun image workstations. Reduction involves parametrization of approx. 10 to the 8th raw data points to a few maps (e.g., velocities of each kinematic subsystem, continuum-free line fluxes) containing approx. 10 to the 5th pixels. Researchers identify kinematic and structural symmetries by examining these maps and the point to point variations of the synthesized line profiles. The combination of monochromatic images and full spatial sampling of line profiles has allowed them to isolate such symmetries and has led to reliable kinematic deprojections.

Cecil, Gerald↗

Chapter 2: Evaluating a Concentrating Solar Power Plantas an Extended-Duration Peaking Resource

We explore the ability of a concentrating solar power (CSP) plant with thermal energy storage (TES) to provide peaking capacity. We focus on future power systems, wherein net load patterns may be significantly different than they are today (e.g., due to higher renewable-energy penetrations). We examine 28 locations in the southwestern United States over an 18-year period. The hourly operation of the CSP plants are simulated to determine their potential to provide energy during an eight-hour peak-load window for each day up to 365 days per year. Our result shows that for the large majority of locations and years, CSP plants with certain configurations (i.e., in terms of solar field and TES sizes) can provide nearly 100% peak-load capacity. We examine also the amount of supplemental energy (e.g.,by using natural gas as a supplemental thermal-energy source) that would be required to ensure that a CSP plant could serve the eight highest-load hours of every day of the year. We find that in most cases, a CSP plant supplemented with natural gas would require less than 5% of the fuel that is used by a natural-gas fired power plant providing the same level of reliable capacity. A series of sensitivity analyses show that these results are robust to the number of peak-load hours and days that are considered and the configuration of the CSP plant.

capacity value↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

A Dual Linear/Circular Polarized Wideband Flat Panel Phased Array Antenna for K/Ka-band 6U CubeSat Communications Applications

Circular polarized (CP) electromagnetic waves are preferred for space-to-space and space-to-ground satellite communications (SATCOM). CubeSats with 6U sizes (1U represents a 10 cm x 10 cm x 10 cm), that will rotate together with the Moon as it orbits Earth require high gain CP antenna systems to maintain reliable communication links. Here, we have designed an 8x8 dual linear and dual circularly polarized phased array antenna (PAA) aperture that offers 22-28 GHz bandwidth, with maximum gain of 23 dBic, and beam scanning capability of ±50o with acceptable axial ratio over all scan angles. A stacked patch topology is selected to achieve wide impedance bandwidth. Each driven patch has two via feed point locations that are connected to grounded coplanar waveguide (CPW) feed structures. By utilizing phase shifters from the Anokiwave RFICs (AWMF-0165) employed for the beamforming network (BFN), we have generated both dual linear polarization and dual circular polarization in each patch. Each driven and parasitic patch is innovatively shaped to achieve excellent isolation between two feed points which, in turn, leads to low cross polarization, high efficiency and good axial ratio over the entire bandwidth. Each chip has eight outputs which feed one 2x2 sub-array consisting of four dual linear or dual circularly polarized driven patches, simultaneously. Each 2x2 sub-array of the 8x8 array are sequentially rotated which improves axial ratio performance when the antenna operates in the dual circularly polarized mode. By utilizing a mirror effect, cross-polarized fields are also improved when operated in a dual linear polarized mode. The 8x8 array aperture is simulated taking into account the effect of the multilayer printed circuit board (PCB) stack-up of the BFN and co-simulated with the power splitter outputs and chip outputs and results are compared with only passive array performance. The performance of the antenna is still excellent when non-ideal chip performances are included in the simulation analysis. The fabricated array will be tested for radiation patterns in the Antenna and Microwave Laboratory (AML) of the San Diego State University and the NASA Glenn Research Center (GRC) spherical near field chambers. The design of the 8x8 antenna array with BFN layout is shown in Fig. 1.

5G↗

Mass measurements of neutron-rich nuclei near $N = 70$

The astrophysical origin for the chemical elements between the first and second r-process peaks is a matter of intense debate, with a number of nucleosynthesis processes at explosive stellar environments possibly contributing to their production. Reliable data on the trends of neutron separation energies of neutron-rich isotopes are required to model neutron-capture processes that would produce these elements. Masses of 104 Y, 106 Zr, 112 Mo, and 115 Tc have been measured with the time-of-flight-magnetic-rigidity (ToF–Bρ) technique at the National Superconducting Cyclotron Laboratory at Michigan State University. The experiment is the first application of the ToF–Bρ technique at the S800 spectrograph that reached the mass region relevant to heavy-element nucleosynthesis. Finally, the two-neutron separation energy deduced from the measured masses exhibits a smooth trend consistent with the theoretical predictions within the range of experimental uncertainty, indicating that there is no sudden shape transition in these isotopes as hinted at by previous data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coronal Magnetography of Solar Active Regions Using Coordinated SOHO/CDS and VLA Observations

The purpose of this project is to apply the coronal magnetographic technique to SOHO (Solar Heliospheric Observatory) /CDS (Coronal Diagnostic Spectrometer) EUV (Extreme Ultraviolet Radiation) and coordinated VLA microwave observations of solar active regions to derive the strength and structure of the coronal magnetic field. A CDS observing plan was developed for obtaining spectra needed to derive active region differential emission measures (DEMs) required for coronal magnetography. VLA observations were proposed and obtained. SOHO JOP 100 was developed, tested, approved, and implemented to obtain coordinated CDS (Coronal Diagnostic Spectrometer)/EIT (Ultraviolet Imaging Telescope)/ VLA (Very Large Array)/ TRACE (Transition Region and Coronal Explorer)/ SXT (Solar X Ray Telescope) observations of active regions on April 12, May 9, May 13, and May 23. Analysis of all four data sets began, with heaviest concentration on COS data. It is found that 200-pixel (14 A in NIS1) wavelength windows are appropriate for extracting broadened Gaussian line profile fit parameters for lines including Fe XIV at 334.2, Fe XVI at 335.4, Fe XVI at 360.8, and Mg IX at 368.1 over the 4 arcmin by 4 arcmin CDS field of view. Extensive efforts were focused on learning and applying were focused on learning and applying CDS software, and including it in new IDL procedures to carry out calculations relating to coronal magnetography. An important step is to extract Gaussian profile fits to all the lines needed to derive the DEM in each spatial pixel of any given active region. The standard CDS absolute intensity calibration software was applied to derived intensity images, revealing that ratios between density-insensitive lines like Fe XVI 360.8/335.4 yield good agreement with theory. However, the resulting absolute intensities of those lines are very high, indicating that revisions to the CDS absolute intensity calibrations remain to be included in the CDS software, an essential step to deriving reliable coronal magnetograms. With lessons learned and high quality data obtained during the past year, coronal magnetography will be successfully pursued under my new SOHO GI program.

Brosius, Jeffrey W.↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998–2022

This report presents an enhanced performance evaluation of the emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2022 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2022. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in Nuclear Regulatory Commission (NRC) probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time-period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed include subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: (1) HPCS EDG FTS failure probability, (2) EPS and HPCS EDG frequency of start demands (demands per reactor year), and (3) EPS and HPCS EDG frequency of FTLR demands. The following decreasing trends were identified for EDGs for the most recent 10-year period: (1) EPS EDG FTS failure probability, (2) EPS EDG FTLR failure probability, (3) EPS EDG unavailability, and (4) EPS and HPCS EDG frequency of FTLR events (failures per reactor year).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification of Bison fission product species conservation under TRISO reactor conditions

When assessing the reliability and predictive capabilities of a simulation tool, code verification is used to ensure that the implemented numerical algorithm is a faithful representation of its underlying mathematical model, including partial differential or integral equations, initial and boundary conditions, and auxiliary relationships. During this process, numerical results in a discrete solution are compared to the analytical solution of the mathematical model. Here, in this paper, the code verification process is applied to one-dimensional spatiotemporal problems that exercise partial differential equation governing the conservation of fission product species (or mass diffusion). Numerical experiments were performed in the Bison fuel performance code to evaluate its predictive capability under various TRISO reactor conditions such as base irradiation and safety heating test conditions for either short- or long-lived fission product species, as well as a case concerning evaporation from the outer surface of a particle. The code predictions were compared with the expected exact results obtained from the analytical expressions, and the fact that they demonstrate the correct analytical behavior provides strong evidence of proper numerical algorithm implementation.

07 ISOTOPE AND RADIATION SOURCES↗