Cryogenic Field Measurement of Pr{sub 2}Fe{sub 14}B Undulator and Performance Enhancement Options at the NSLS-II

Short period (14.5mm) hybrid undulator arrays composed of Praseodymium Iron Boron (Pr{sub 2}Fe{sub 14}B) magnets (CR53, NEOMAX, Inc.) and vanadium permendur poles have been fabricated at Brookhaven National Laboratory. Unlike Neodymium Iron Boron (Nd{sub 2}Fe{sub 14}B) magnets which exhibit spin reorientation at a temperatures below 150 K, PrFeB arrays monotonically increase performance with lower operating temperature. It opens up the possibility for use in operating a cryo-permanent magnet undulator (CPMU) in the range of 40 K to 60 K where very efficient cryocoolers are available. Magnetic flux density profiles were measured at various temperature ranges from room temperature down to liquid helium (LHe) using the Vertical Testing Facility (VTF) at the National Synchrotron Light Source-II (NSLS-II). Temperature variations of phase error have been characterized. In addition, we examined the use of textured Dysprosium (Dy) poles to replace permendur poles to obtain further improvement in performance.

43 PARTICLE ACCELERATORS↗

Saturn Neutron Exosphere as Source for Inner and Innermost Radiation Belts

Energetic proton and electron measurements by the ongoing Cassini orbiter mission are expanding our knowledge of the highest energy components of the Saturn magnetosphere in the inner radiation belt region after the initial discoveries of these belts by the Pioneer 11 and Voyager 2 missions. Saturn has a neutron exosphere that extends throughout the magnetosphere from the cosmic ray albedo neutron source at the planetary main rings and atmosphere. The neutrons emitted from these sources at energies respectively above 4 and 8 eV escape the Saturn system, while those at lower energies are gravitationally bound. The neutrons undergo beta decay in average times of about 1000 seconds to provide distributed sources of protons and electrons throughout Saturn's magnetosphere with highest injection rates close to the Saturn and ring sources. The competing radiation belt source for energetic electrons is rapid inward diffusion and acceleration of electrons from the middle magnetosphere and beyond. Minimal losses during diffusive transport across the moon orbits, e.g. of Mimas and Enceladus, and local time asymmetries in electron intensity, suggest that drift resonance effects preferentially boost the diffusion rates of electrons from both sources. Energy dependences of longitudinal gradient-curvature drift speeds relative to the icy moons are likely responsible for hemispheric differences (e.g., Mimas, Tethys) in composition and thermal properties as at least partly produced by radiolytic processes. A continuing mystery is the similar radial profiles of lower energy (<10 MeV) protons in the inner belt region. Either the source of these lower energy protons is also neutron decay, but perhaps alternatively from atmospheric albedo, or else all protons from diverse distributed sources are similarly affected by losses at the moon' orbits, e.g. because the proton diffusion rates are extremely low. Enceladus cryovolcanism, and radiolytic processing elsewhere on the icy moon and ring surfaces, are additional sources of protons via ionization and charge exchange from breakup of water molecules. But one must then account somehow for local acceleration to the observed keV-MeV energies, since moon sweeping and E-ring absorption would remove protons diffusing inward from the middle magnetosphere. Although the main rings block further inward diffusion from the inner radiation belts, the exospheric neutron-decay source, combined with much slower diffusion of protons relative to electrons, may produce an innermost radiation belt in the gap between the upper atmosphere and the D-ring. This innermost belt will first be explored in-situ during the final proximal orbits of the Cassini mission.

Cooper, John↗

Automated management of radioactive sources in Saudi Arabia

For usage of radioactive substances, any facility has to register and take license from relevant authority of the country in which such facility is operating. In the Kingdom of Saudi Arabia (KSA), the authority for managing radioactive sources and providing licenses to organizations for its usage is the National Center of Radiation Protection (NCRP). This paper describes the system that automates registration and licensing process of the National Center of Radiation Protection. To provide 24×7 accesses to all the customers of NCRP, system is developed as web-based application that provide facility to online register, request license, renew license, check request status, view historical data and reports etc. and other features are provided as Electronic Services that would be accessible to users via internet. The system also was designed to streamline and optimize internal operations of NCRP besides providing ease of access to its customers by implementing a defined workflow through which every registration and license request will be routed. In addition to manual payment option, the system would also be integrated with SADAD (online payment system) that will avoid lengthy and cumbersome procedures associated with manual payment mechanism. Using SADAD payment option license fee could be paid through internet/ATM machine or branch of any designated bank, Payment will be instantly notified to NCRP hence delay in funds transfer and verification of invoice could be avoided, SADAD integration is discussed later in the document.

07 ISOTOPE AND RADIATION SOURCES↗

Time dependence of energy spectra of brachytherapy sources and its impact on the half and the tenth value layers

Purpose: Several factors including radionuclide purity influence the photon energy spectra from sealed brachytherapy sources. The existence of impurities and trace elements in radioactive materials as well as the substrate and encapsulation may not only alter the spectrum at a given time but also cause change in the spectra as a function of time. The purpose of this study is to utilize a semiempirical formalism, which quantitatively incorporates this time dependence, to calculate and evaluate the shielding requirement impacts introduced by this time dependence for a {sup 103}Pd source. Methods: The formalism was used to calculate the NthVL thicknesses in lead for a {sup 103}Pd model 200 seed. Prior to 2005, the {sup 103}Pd in this source was purified to a level better than 0.006% of the total {sup 103}Pd activity, the key trace impurity consisting of {sup 65}Zn. Because {sup 65}Zn emits higher energy photons and has a much longer half-life of 244 days compared to {sup 103}Pd, its presence in {sup 103}Pd seeds led to a time dependence of the photon spectrum and other related physical quantities. This study focuses on the time dependence of the NthVL and the analysis of the corresponding shielding requirements. Results: The results indicate that the first HVL and the first TVL in lead steadily increased with time for about 200 days and then reached a plateau. The increases at plateau were more than 1000 times compared to the corresponding values on the zeroth day. The second and third TVLs in lead reached their plateaus in about 100 and 60 days, respectively, and the increases were about 19 and 2.33 times the corresponding values on the zeroth day, respectively. All the TVLs demonstrated a similar time dependence pattern, with substantial increases and eventual approach to a plateau. Conclusions: The authors conclude that the time dependence of the emitted photon spectra from brachytherapy sources can introduce substantial variations in the values of the NthVL with time if certain impurities are present. The contribution of {sup 65}Zn to the dose rate constant was less than 0.03% in the earlier {sup 103}Pd seeds, and because of the use of new processing technologies since 2005, this impurity has been essentially eliminated, as demonstrated in the measured spectra of current {sup 103}Pd model 200 seeds. This study illustrates the importance of performing photon spectroscopy of the manufactured radioactive sources as a quality assurance test for an assessment over time of both the radiation protection and the dosimetric properties.

07 ISOTOPE AND RADIATION SOURCES↗

Hard X-ray Phase-Contrast Tomographic Nanoimaging

Synchrotron-based full-field tomographic microscopy established itself as a tool for noninvasive investigations. Many beamlines worldwide routinely achieve micrometer spatial resolution while the isotropic 100-nm barrier is reached and trespassed only by few instruments, mainly in the soft x-ray regime. We present an x-ray, full-field microscope with tomographic capabilities operating at 10 keV and with a 3D isotropic resolution of 144 nm recently installed at the TOMCAT beamline of the Swiss Light Source. Custom optical components, including a beam-shaping condenser and phase-shifting dot arrays, were used to obtain an ideal, aperture-matched sample illumination and very sensitive phase-contrast imaging. The instrument has been successfully used for the nondestructive, volumetric investigation of single, unstained cells.

43 PARTICLE ACCELERATORS↗

Review of the Digital Inject Book

The DIB greatly simplifies some aspects of generating inject data and also enables one to rapidly make changes to the scenario and generate new data. The underlying code for generating gamma ray inject data is GADRAS, while the underlying code for generating most of the neutron inject data is SrcSim. Since GADRAS has been around for a significant period of time and has a relatively large user base, reviewing GADRAS itself was considered out of scope for this TI project. However, how the DIB utilizes and interfaces with GADRAS to generate the inject data was considered to be in scope. SrcSim on the other hand does not have the same kind of pedigree as GADRAS and has not been as widely evaluated. Therefore, this review will cover not only how the DIB interfaces with SrcSim, but also the SrcSim code itself.

07 ISOTOPE AND RADIATION SOURCES↗

Study on the Effect of Energy Parameter of Electron on the Percentage Depth Dose of Electron Beam Using Monte Carlo Method

In medical linear accelerator, the energy parameter of electron plays important role to produce electron beam. The percentage depth dose of electron beams takes account not only on the value of electron's energy, but also on the type of electron's energy. The aims of this work are to carry on the effect of energy parameter of electron on the percentage depth dose of electron beam. Monte Carlo method is chosen in this project, due to the superior of this method for simulating the random process such as the transport particle in matter. The DOSXYZnrc usercode was used to simulate the electron transport in water phantom. Two aspects of electron's energy parameter were investigated using Monte Carlo simulations. In the first aspect, electron energy's value was varied also its spectrum. In the second aspect, the geometry of electron's energy was taken account on. The parallel beam and the point source were chosen as the geometry of The measurements of percentage depth dose were conducted to compare with its simulation. The ionization chamber was used in these measurements. Presentation of the results of this work is given not only based on the shape of the percentage depth dose from the simulation and measurement, but also on the other aspect in its curve. The result of comparison between the simulation and its measurement shows that the shape of its curve depends on the energy value of electron and the type of its energy. The energy value of electron affected the depth maximum of dose.

07 ISOTOPE AND RADIATION SOURCES↗

Commissioning of Angle Dispersive X-ray Diffraction Beamline on Indus-2

An Angle dispersive x-ray diffraction (ADXRD) beamline on bending magnet source of Indus-2 synchrotron (2.5 GeV, 300 mA) has been commissioned, for the study of single and polycrystalline samples. The beamline optics is based on vertically focusing Pt-coated pre and post mirrors and sagittal focusing Si (311) based double crystal monochromator. Experimental station consists of a six circle diffractometer equipped with scintillation detector and an image plate area detector for powder diffraction. XRD experiments have been performed to study single crystal and polycrystalline samples.

43 PARTICLE ACCELERATORS↗

Single-shot Femtosecond X-Ray Holography Using Extended References

In the context of x-ray lensless imaging, we present a recent approach for Fourier transform holography based on the use of extended references. Major advances shown here rely on a high signal efficiency and on the direct image reconstruction of the object performed by a simple linear derivative. Moreover, the extended holographic reference is easy to manufacture and can be applied to a variety of imaging experiments. Here we demonstrate single-shot imaging with a table-top, laser-based coherent soft x-ray source. A spatial resolution of 110 nm was obtained with an integration time of 20 fs.

07 ISOTOPE AND RADIATION SOURCES↗

Techniques for Handling Channeling in High Resolution Fourier Transform Spectra Recorded with Synchrotron Sources

Seven different techniques in dealing the problem of channel spectra in Fourier transform Spectroscopy utilizing synchrotron source were examined and compared. Five of these techniques deal with the artifacts (spikes) in the recorded interferogram which in turn result in channel spectra within the spectral domain. Such interferogram editing method include replacing these spikes with zeros, straight line, fitted polynomial curve, rescaled spike and spike reduced with Gauss Function. Another two techniques try to target this issue in the spectral domain instead by either generating a synthetic background simulating the channels or measuring the channels parameters (amplitude, spacing and phase) to use in the spectral fitting program. Results showed spectral domain techniques produces higher quality results in terms of signal to noise and fitting residual. The effect of each method on the line parameters such as position, intensity are air broadening are also measured and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Novel Self-Expandable, Radioactive Airway Stent Loaded with {sup 125}I Seeds: A Feasibility and Safety Study in Healthy Beagle Dog

PurposeAirway stent placement is an effective treatment for the immediate palliation of malignant airway obstruction. However, restenosis caused by tumor ingrowth and/or overgrowth after stenting is common. The purpose of this study was to investigate the feasibility and safety of a novel self-expandable stent loaded with {sup 125}I seeds in healthy beagle dog.Materials and MethodsUnder fluoroscopic guidance, forty-eight self-expandable airway stents loaded with {sup 125}I seeds were perorally placed in the main trachea of 48 healthy beagle dogs, who were randomly divided into four groups (Group A: 0.3 mCi; Group B: 0.6 mCi; Group C: 0.9 mCi; Control group: 0 mCi). The estimated radiation dose was calculated using the isotropic point source approximation. Radiological follow-up examinations and histopathological examinations of stented tracheal segments and their adjacent organs and tissues were performed at 2, 4, 8, and 16 weeks following the stenting.ResultsAll stents were successfully deployed in the targeted tracheal segment in the beagle dogs without procedure-related complications. Tracheal stenosis became severe gradually in all the four groups, which was not associated with the radioactivity of {sup 125}I seeds (p > 0.05). The tracheal injury scores increased along with the higher dose of radioactive seeds which reached peak at 8 weeks and then turned back slightly at 16 weeks. The adjacent tissue did not show pathohistological changes under microscope, while mild and reversible ultrastructure changes were showed under electronic microscope.ConclusionsThis study demonstrates that it is feasible and safe to insert this novel self-expandable airway stent loaded with {sup 125}I seeds in healthy beagle dog.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A highly-enriched 244 Pu reference material for nuclear safeguards and nuclear forensics measurements

A highly-enriched 244 Pu isotope dilution reference material has been prepared and characterized for metrologically traceable measurements of very small quantities of plutonium. The amount of plutonium in samples associated with nuclear safeguards and nuclear forensic measurements can be significantly less than 1 ng. Accordingly, the ability to quantify the amount and isotopic composition of plutonium from a single mass-spectrometric analysis is particularly desirable. The highly-enriched 244 Pu reference material, described here, will minimize the magnitude of spike corrections necessary to obtain accurate information on plutonium isotopic composition from isotope dilution measurements.

07 ISOTOPE AND RADIATION SOURCES↗

Exploring rapid chemical separations of Sc-47 produced from photonuclear reactions on natural vanadium targets

Scandium-47 ( 47 Sc) production via bremsstrahlung irradiation of natural vanadium targets offers significant advantages for producing high purity 47 Sc; this work evaluates several rapid dissolution and chemical separation techniques for recovering high purity 47 Sc from irradiated vanadium. Here, techniques developed are combined into a simple, gram-scale, semi-automated target processing system that enables 47 Sc recovery from irradiated vanadium targets with chemical yields as high as 93 ± 3% and 47 Sc/V separation factors of 6 ± 3 ·10 11 within 90 min total processing times. Future research into H 2 O 2 resistant separation techniques and their applicability for direct process coupling to chelation are recommended.

07 ISOTOPE AND RADIATION SOURCES↗

Production and separation of carrier-free 7 Be

A high-purity carrier-free 7 Be was efficiently isolated following proton bombardment of a lithium hydroxide - aluminum target. The separation of beryllium from lithium and aluminum was achieved through a hydrochloric acid elution system utilizing cation exchange chromatography. The beryllium recovery, +99%, was assessed through gamma spectroscopy while the chemical purity was established by mass spectrometry. In conclusion, the decontamination factors of beryllium from lithium and aluminum were determined to be 6900 and 300, respectively.

07 ISOTOPE AND RADIATION SOURCES↗

A new thorium-229 reference material

A new reference material was characterized for 229 Th molality and thorium isotope amount ratios. This reference material is intended for use in nuclear forensic analyses as an isotope dilution mass spectrometry spike. The reference material value and expanded uncertainty (k = 2) for the 229 Th molality is (1.1498 ± 0.0016)×10 -10 mol g -1 solution. The value and expanded uncertainty (k = 2) for the n( 230 Th)/n( 229 Th) ratio is (5.18 ± 0.26)×10 -5 and the n( 232 Th)/n( 229 Th) ratio is (3.815 ± 0.092)×10 -4 .

07 ISOTOPE AND RADIATION SOURCES↗

Half-life determination and comparison of activity standards of 231 Pa

The results of an international comparison of activity measurements of a solution of 231 Pa are reported and analysed. Prior to this, no known standardisation of 231 Pa by activity measurement had been carried out. The comparison was run in 2017–2018 involving eight laboratories, and returned results with no identifiable inconsistencies between methods or laboratories. The results, including one mass determination, gave a 231 Pa activity concentration of 41.461(48) kBq g -1 and a 231 Pa atom concentration of 61.48(23) × 10 15 atoms g -1 , from which a half-life value of 32 570(130) years was derived.

Half-life↗