Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Cone-Beam CT Assessment of Interfraction and Intrafraction Setup Error of Two Head-and-Neck Cancer Thermoplastic Masks

Purpose: To prospectively compare setup error in standard thermoplastic masks and skin-sparing masks (SSMs) modified with low neck cutouts for head-and-neck intensity-modulated radiation therapy (IMRT) patients. Methods and Materials: Twenty head-and-neck IMRT patients were randomized to be treated in a standard mask (SM) or SSM. Cone-beam computed tomography (CBCT) scans, acquired daily after both initial setup and any repositioning, were used for initial and residual interfraction evaluation, respectively. Weekly, post-IMRT CBCT scans were acquired for intrafraction setup evaluation. The population random (sigma) and systematic (SIGMA) errors were compared for SMs and SSMs. Skin toxicity was recorded weekly by use of Radiation Therapy Oncology Group criteria. Results: We evaluated 762 CBCT scans in 11 patients randomized to the SM and 9 to the SSM. Initial interfraction sigma was 1.6 mm or less or 1.1 deg. or less for SM and 2.0 mm or less and 0.8 deg. for SSM. Initial interfraction SIGMA was 1.0 mm or less or 1.4 deg. or less for SM and 1.1 mm or less or 0.9 deg. or less for SSM. These errors were reduced before IMRT with CBCT image guidance with no significant differences in residual interfraction or intrafraction uncertainties between SMs and SSMs. Intrafraction sigma and SIGMA were less than 1 mm and less than 1 deg. for both masks. Less severe skin reactions were observed in the cutout regions of the SSM compared with non-cutout regions. Conclusions: Interfraction and intrafraction setup error is not significantly different for SSMs and conventional masks in head-and-neck radiation therapy. Mask cutouts should be considered for these patients in an effort to reduce skin toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toxicity Analysis of Postoperative Image-Guided Intensity-Modulated Radiotherapy for Prostate Cancer

Purpose: To report on the acute and late gastrointestinal (GI) and genitourinary (GU) toxicity associated with a unique technique of image-guided radiotherapy (IGRT) in patients undergoing postprostatectomy irradiation. Methods and Materials: Fifty patients were treated with intensity-modulated radiation therapy (IMRT) after radical prostatectomy. Daily image guidance was performed to localize the prostate bed using kilovoltage imaging or cone-beam computed tomography. The median prescription dose was 68 Gy (range, 62-68 Gy). Toxicity was graded every 3 to 6 months according to the Common Terminology Criteria for Adverse Events version 3.0. Results: The median follow-up was 24 months (range, 13-38 months). Grade 2 acute GI and GU events occurred in 4 patients (8%) and 7 patients (14%), respectively. No Grade 3 or higher acute GI or GU toxicities were observed. Late Grade 2 GI and GU events occurred in 1 patient (2%) and 8 patients (16%), respectively. Only a single (2%) Grade 3 or higher late toxicity was observed. Conclusions: Image-guided IMRT in the postprostatectomy setting is associated with a low frequency of acute and late GI/GU toxicity. These results compare more favorably to radiotherapy techniques that do not use in-room image-guidance, suggesting that daily prostate bed localization may reduce the incidence of adverse events in patients undergoing postprostatectomy irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Experience With Volumetric IMRT (RapidArc) for Intracranial Stereotactic Radiosurgery

Purpose: Initial experience with delivering frameless stereotactic radiotherapy (SRT) using volumetric intensity-modulated radiation therapy (IMRT) delivered with RapidArc is presented. Methods and Materials: Treatment details for 12 patients (14 targets) with a mean clinical target volume (CTV) of 12.8 {+-} 4.0 cm{sup 3} were examined. Dosimetric indices for conformality, homogeneity, and dose gradient were calculated and compared with published results for other frameless, intracranial SRT techniques, including CyberKnife, TomoTherapy, and static-beam IMRT. Statistics on setup and treatment times and per patient dose validations were examined. Results: Dose indices compared favorably with other techniques. Mean conformality, gradient, and homogeneity index values were 1.10 {+-} 0.11, 64.9 {+-} 14.1, 1.083 {+-} 0.026, respectively. Median treatment times were 4.8 {+-} 1.7 min. Conclusion: SRT using volumetric IMRT is a viable alternative to other techniques and enables short treatment times. This is anticipated to have a positive impact on radiobiological effect and for facilitating wider use of SRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase I Trial of Pelvic Nodal Dose Escalation With Hypofractionated IMRT for High-Risk Prostate Cancer

Purpose: Toxicity concerns have limited pelvic nodal prescriptions to doses that may be suboptimal for controlling microscopic disease. In a prospective trial, we tested whether image-guided intensity-modulated radiation therapy (IMRT) can safely deliver escalated nodal doses while treating the prostate with hypofractionated radiotherapy in 5 Vulgar-Fraction-One-Half weeks. Methods and Materials: Pelvic nodal and prostatic image-guided IMRT was delivered to 53 National Comprehensive Cancer Network (NCCN) high-risk patients to a nodal dose of 56 Gy in 2-Gy fractions with concomitant treatment of the prostate to 70 Gy in 28 fractions of 2.5 Gy, and 50 of 53 patients received androgen deprivation for a median duration of 12 months. Results: The median follow-up time was 25.4 months (range, 4.2-57.2). No early Grade 3 Radiation Therapy Oncology Group or Common Terminology Criteria for Adverse Events v.3.0 genitourinary (GU) or gastrointestinal (GI) toxicities were seen. The cumulative actuarial incidence of Grade 2 early GU toxicity (primarily alpha blocker initiation) was 38%. The rate was 32% for Grade 2 early GI toxicity. None of the dose-volume descriptors correlated with GU toxicity, and only the volume of bowel receiving {>=}30 Gy correlated with early GI toxicity (p = 0.029). Maximum late Grades 1, 2, and 3 GU toxicities were seen in 30%, 25%, and 2% of patients, respectively. Maximum late Grades 1 and 2 GI toxicities were seen in 30% and 8% (rectal bleeding requiring cautery) of patients, respectively. The estimated 3-year biochemical control (nadir + 2) was 81.2 {+-} 6.6%. No patient manifested pelvic nodal failure, whereas 2 experienced paraaortic nodal failure outside the field. The six other clinical failures were distant only. Conclusions: Pelvic IMRT nodal dose escalation to 56 Gy was delivered concurrently with 70 Gy of hypofractionated prostate radiotherapy in a convenient, resource-efficient, and well-tolerated 28-fraction schedule. Pelvic nodal dose escalation may be an option in any future exploration of potential benefits of pelvic radiation therapy in high-risk prostate cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Arc Therapy for Pediatric Posterior Fossa Tumors

Purpose: To compare intensity-modulated arc therapy (IMAT) to noncoplanar intensity-modulated radiation therapy (IMRT) in the treatment of pediatric posterior fossa tumors. Methods and Materials: Nine pediatric patients with posterior fossa tumors, mean age 9 years (range, 6-15 years), treated using IMRT were chosen for this comparative planning study because of their tumor location. Each patient's treatment was replanned to receive 54 Gy to the planning target volume (PTV) using five different methods: eight-field noncoplanar IMRT, single coplanar IMAT, double coplanar IMAT, single noncoplanar IMAT, and double noncoplanar IMAT. For each method, the dose to 95% of the PTV was held constant, and the doses to surrounding critical structures were minimized. The different plans were compared based on conformity, total linear accelerator dose monitor units, and dose to surrounding normal tissues, including the entire body, whole brain, temporal lobes, brainstem, and cochleae. Results: The doses to the target and critical structures for the various IMAT methods were not statistically different in comparison with the noncoplanar IMRT plan, with the following exceptions: the cochlear doses were higher and whole brain dose was lower for coplanar IMAT plans; the cochleae and temporal lobe doses were lower and conformity increased for noncoplanar IMAT plans. The advantage of the noncoplanar IMAT plan was enhanced by doubling the treatment arc. Conclusion: Noncoplanar IMAT results in superior treatment plans when compared to noncoplanar IMRT for the treatment of posterior fossa tumors. IMAT should be considered alongside IMRT when treatment of this site is indicated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Increased Risk of Ischemic Stroke in Young Nasopharyngeal Carcinoma Patients

Purpose: Radiation/chemoradiotherapy-induced carotid stenosis and cerebrovascular events in patients with nasopharyngeal carcinoma (NPC) can cause severe disability and even death. This study aimed to estimate the risk of ischemic stroke in this patient population over more than 10 years of follow-up. Methods and Materials: The study cohorts consisted of all patients hospitalized with a principal diagnosis of NPC (n = 1094), whereas patients hospitalized for an appendectomy during 1997 and 1998 (n = 4376) acted as the control group and surrogate for the general population. Cox proportional hazard model was performed as a means of comparing the stroke-free survival rate between the two cohorts after adjusting for possible confounding and risk factors. Results: Of the 292 patients with ischemic strokes, 62 (5.7%) were from the NPC cohort and 230 (5.3%) were from the control group. NPC patients ages 35-54 had a 1.66 times (95% CI, 1.16-2.86; p = 0.009) higher risk of ischemic stroke after adjusting for patient characteristics, comorbidities, geographic region, urbanization level of residence, and socioeconomic status. There was no statistical difference in ischemic stroke risk between the NPC patients and appendectomy patients ages 55-64 years (hazard ratio = 0.87; 95% CI, 0.56-1.33; p = 0.524) after adjusting for other factors. Conclusions: Young NPC patients carry a higher risk for ischemic stroke than the general population. Besides regular examinations of carotid duplex, different irradiation strategies or using new technique of radiotherapy, such as intensity modulated radiation therapy or volumetric modulated arc therapy, should be considered in young NPC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of Pretreatment FDG-PET in Nasopharyngeal Carcinoma Treated With Intensity-Modulated Radiotherapy

Purpose: Pretreatment with 2- [{sup 18}F] fluorodeoxyglucose positron emission tomography ({sup 18}F-FDG-PET) was evaluated as a predictor of local failure-free survival (LFFS), disease-free survival (DFS), and overall survival (OS) in patients with nonkeratinizing nasopharyngeal carcinoma (NPC) treated with intensity-modulated radiation therapy (IMRT) alone or concurrently with chemotherapy (CCRT). Patients and Methods: Seventy-five M0 NPC patients who received FDG-PET before treatment were analyzed. The primary tumor FDG uptake was measured as the maximum standardized uptake value (SUVmax). The LFFS, DFS, and OS were calculated by the Kaplan-Meier method, and the differences were evaluated on log-rank test. The prognostic significance was assessed by univariate and multivariate analyses. Results: Eighteen patients received IMRT alone and 57 received CCRT. The mean SUVmax was significantly higher in 12 patients with locoregional or distant failure than in those without failure (p <0.001). On multivariate analysis, the SUVmax was the only significant variable for 5-year LFFS (p = 0.017) and DFS (p = 0.000) but not for OS (p = 0.065). Conclusion: SUVmax is a potential independent prognostic predictor of clinical outcomes in patients with nasopharyngeal carcinoma treated with IMRT alone or with CCRT. A high {sup 18}F-FDG uptake (SUVmax >5) indicates poor outcome in patients with NPC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Practical Method of Adaptive Radiotherapy for Prostate Cancer Using Real-Time Electromagnetic Tracking

Purpose: We have created an automated process using real-time tracking data to evaluate the adequacy of planning target volume (PTV) margins in prostate cancer, allowing a process of adaptive radiotherapy with minimal physician workload. We present an analysis of PTV adequacy and a proposed adaptive process. Methods and Materials: Tracking data were analyzed for 15 patients who underwent step-and-shoot multi-leaf collimation (SMLC) intensity-modulated radiation therapy (IMRT) with uniform 5-mm PTV margins for prostate cancer using the Calypso Registered-Sign Localization System. Additional plans were generated with 0- and 3-mm margins. A custom software application using the planned dose distribution and structure location from computed tomography (CT) simulation was developed to evaluate the dosimetric impact to the target due to motion. The dose delivered to the prostate was calculated for the initial three, five, and 10 fractions, and for the entire treatment. Treatment was accepted as adequate if the minimum delivered prostate dose (D{sub min}) was at least 98% of the planned D{sub min}. Results: For 0-, 3-, and 5-mm PTV margins, adequate treatment was obtained in 3 of 15, 12 of 15, and 15 of 15 patients, and the delivered D{sub min} ranged from 78% to 99%, 96% to 100%, and 99% to 100% of the planned D{sub min}. Changes in D{sub min} did not correlate with magnitude of prostate motion. Treatment adequacy during the first 10 fractions predicted sufficient dose delivery for the entire treatment for all patients and margins. Conclusions: Our adaptive process successfully used real-time tracking data to predict the need for PTV modifications, without the added burden of physician contouring and image analysis. Our methods are applicable to other uses of real-time tracking, including hypofractionated treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors of IMRT and Conformal Radiotherapy Use in Head and Neck Squamous Cell Carcinoma: A SEER-Medicare Analysis

Purpose: The extent to which new techniques for the delivery of radiotherapy for head and neck squamous cell carcinoma (HNSCC) have diffused into clinical practice is unclear, including the use of 3-dimensional conformal RT (3D-RT) and intensity-modulated radiation therapy (IMRT). Methods and Materials: Using the Surveillance, Epidemiology, and End Results (SEER)-Medicare linked database, we identified 2,495 Medicare patients with Stage I-IVB HNSCC diagnosed at age 65 years or older between 2000 and 2005 and treated with either definitive (80%) or adjuvant (20%) radiotherapy. Our primary aim was to analyze the trends and predictors of IMRT use over this time, and the secondary aim was a similar description of the trends and predictors of conformal radiotherapy (CRT) use, defined as treatment with either 3D-RT or IMRT. Results: Three hundred sixty-four (15%) patients were treated with IMRT, and 1,190 patients (48%) were treated with 3D-RT. Claims for IMRT and CRT rose from 0% to 33% and 39% to 86%, respectively, between 2000 and 2005. On multivariable analysis, IMRT use was associated with SEER region (West 18%; Northeast 11%; South 12%; Midwest 13%), advanced stage (advanced, 21%; early, 9%), non-larynx site (non-larynx, 23%; larynx, 7%), higher median census tract income (highest vs. lowest quartile, 18% vs. 10%), treatment year (2003-2005, 31%; 2000-2002, 6%), use of chemotherapy (26% with; 9% without), and higher radiation oncologist treatment volume (highest vs. lowest tertile, 23% vs. 8%). With CRT as the outcome, only SEER region, treatment year, use of chemotherapy, and increasing radiation oncologist HNSCC volume were significant on multivariable analysis. Conclusions: The use of IMRT and CRT by Medicare beneficiaries with HNSCC rose significantly between 2000 and 2005 and was associated with both clinical and non-clinical factors, with treatment era and radiation oncologist HNSCC treatment volume serving as the strongest predictors of IMRT use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Assessment of Renal Motion in Children as Measured via Four-Dimensional Computed Tomography

Objectives: Abdominal intensity-modulated radiation therapy and proton therapy require quantification of target and organ motion to optimize localization and treatment. Although addressed in adults, there is no available literature on this issue in pediatric patients. We assessed physiologic renal motion in pediatric patients. Methods and Materials: Twenty free-breathing pediatric patients at a median age of 8 years (range, 2-18 years) with intra-abdominal tumors underwent computed tomography simulation and four-dimensional computed tomography acquisition (slice thickness, 3 mm). Kidneys and diaphragms were contoured during eight phases of respiration to estimate center-of-mass motion. We quantified center of kidney mass mobility vectors in three dimensions: anteroposterior (AP), mediolateral (ML), and superoinferior (SI). Results: Kidney motion decreases linearly with decreasing age and height. The 95% confidence interval for the averaged minima and maxima of renal motion in children younger than 9 years was 5-9 mm in the ML direction, 4-11 mm in the AP direction, and 12-25 mm in the SI dimension for both kidneys. In children older than 9 years, the same confidence interval reveals a widening range of motion that was 5-16 mm in the ML direction, 6-17 mm in the AP direction, and 21-52 mm in the SI direction. Although not statistically significant, renal motion correlated with diaphragm motion in older patients. The correlation between diaphragm motion and body mass index was borderline (r = 0.52, p = 0.0816) in younger patients. Conclusions: Renal motion is age and height dependent. Measuring diaphragmatic motion alone does not reliably quantify pediatric renal motion. Renal motion in young children ranges from 5 to 25 mm in orientation-specific directions. The vectors of motion range from 5 to 52 mm in older children. These preliminary data represent novel analyses of pediatric intra-abdominal organ motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Clinical Outcome of Intensity-Modulated Radiotherapy for Inoperable Non-Small Cell Lung Cancer: The MD Anderson Experience

Purpose: In 2007, we published our initial experience in treating inoperable non-small-cell lung cancer (NSCLC) with intensity-modulated radiation therapy (IMRT). The current report is an update of that experience with long-term follow-up. Methods and Materials: Patients in this retrospective review were 165 patients who began definitive radiotherapy, with or without chemotherapy, for newly diagnosed, pathologically confirmed NSCLC to a dose of {>=}60 Gy from 2005 to 2006. Early and late toxicities assessed included treatment-related pneumonitis (TRP), pulmonary fibrosis, esophagitis, and esophageal stricture, scored mainly according to the Common Terminology Criteria for Adverse Events 3.0. Other variables monitored were radiation-associated dermatitis and changes in body weight and Karnofsky performance status. The Kaplan-Meier method was used to compute survival and freedom from radiation-related acute and late toxicities as a function of time. Results: Most patients (89%) had Stage III to IV disease. The median radiation dose was 66 Gy given in 33 fractions (range, 60-76 Gy, 1.8-2.3 Gy per fraction). Median overall survival time was 1.8 years; the 2-year and 3-year overall survival rates were 46% and 30%. Rates of Grade {>=}3 maximum TRP (TRP{sub max}) were 11% at 6 months and 14% at 12 months. At 18 months, 86% of patients had developed Grade {>=}1 maximum pulmonary fibrosis (pulmonary fibrosis{sub max}) and 7% Grade {>=}2 pulmonary fibrosis{sub max}. The median times to maximum esophagitis (esophagitis{sub max}) were 3 weeks (range, 1-13 weeks) for Grade 2 and 6 weeks (range, 3-13 weeks) for Grade 3. A higher percentage of patients who experienced Grade 3 esophagitis{sub max} later developed Grade 2 to 3 esophageal stricture. Conclusions: In our experience, using IMRT to treat NSCLC leads to low rates of pulmonary and esophageal toxicity, and favorable clinical outcomes in terms of survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Body Mass Index on Intrafraction Prostate Displacement Monitored by Real-Time Electromagnetic Tracking

Purpose: To evaluate, using real-time monitoring of implanted radiofrequency transponders, the intrafraction prostate displacement of patients as a function of body mass index (BMI). Methods and Materials: The motions of Beacon radiofrequency transponders (Calypso Medical Technologies, Seattle, WA) implanted in the prostate glands of 66 men were monitored throughout the course of intensity modulated radiation therapy. Data were acquired at 10 Hz from setup to the end of treatment, but only the 1.7 million data points with a 'beam on' tag were used in the analysis. There were 21 obese patients, with BMI {>=}30 and 45 nonobese patients in the study. Results: Mean displacements were least in the left-right lateral direction (0.56 {+-} 0.24 mm) and approximately twice that magnitude in the superior-inferior and anterior-posterior directions. The net vector displacement was larger still, 1.95 {+-} 0.47 mm. Stratified by BMI cohort, the mean displacements per patient in the 3 Cartesian axes as well as the net vector for patients with BMI {>=}30 were slightly less (<0.2 mm) but not significantly different than the corresponding values for patients with lower BMIs. As a surrogate for the magnitude of oscillatory noise, the standard deviation for displacements in all measured planes showed no significant differences in the prostate positional variability between the lower and higher BMI groups. Histograms of prostate displacements showed a lower frequency of large displacements in obese patients, and there were no significant differences in short-term and long-term velocity distributions. Conclusions: After patients were positioned accurately using implanted radiofrequency transponders, the intrafractional displacements in the lateral, superior-inferior, and anterior-posterior directions as well as the net vector displacements were smaller, but not significantly so, for obese men than for those with lower BMI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comprehensive Comparison of IMRT and VMAT Plan Quality for Prostate Cancer Treatment

Purpose: We performed a comprehensive comparative study of the plan quality between volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) for the treatment of prostate cancer. Methods and Materials: Eleven patients with prostate cancer treated at our institution were randomly selected for this study. For each patient, a VMAT plan and a series of IMRT plans using an increasing number of beams (8, 12, 16, 20, and 24 beams) were examined. All plans were generated using our in-house-developed automatic inverse planning (AIP) algorithm. An existing eight-beam clinical IMRT plan, which was used to treat the patient, was used as the reference plan. For each patient, all AIP-generated plans were optimized to achieve the same level of planning target volume (PTV) coverage as the reference plan. Plan quality was evaluated by measuring mean dose to and dose-volume statistics of the organs at risk, especially the rectum, from each type of plan. Results: For the same PTV coverage, the AIP-generated VMAT plans had significantly better plan quality in terms of rectum sparing than the eight-beam clinical and AIP-generated IMRT plans (p < 0.0001). However, the differences between the IMRT and VMAT plans in all the dosimetric indices decreased as the number of beams used in IMRT increased. IMRT plan quality was similar or superior to that of VMAT when the number of beams in IMRT was increased to a certain number, which ranged from 12 to 24 for the set of patients studied. The superior VMAT plan quality resulted in approximately 30% more monitor units than the eight-beam IMRT plans, but the delivery time was still less than 3 min. Conclusions: Considering the superior plan quality as well as the delivery efficiency of VMAT compared with that of IMRT, VMAT may be the preferred modality for treating prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Individualized Dose Prescription for Hypofractionation in Advanced Non-Small-Cell Lung Cancer Radiotherapy: An in silico Trial

Purpose: Local tumor control and outcome remain poor in patients with advanced non-small-cell lung cancer (NSCLC) treated by external beam radiotherapy. We investigated the therapeutic gain of individualized dose prescription with dose escalation based on normal tissue dose constraints for various hypofractionation schemes delivered with intensity-modulated radiation therapy. Methods and Materials: For 38 Stage III NSCLC patients, the dose level of an existing curative treatment plan with standard fractionation (66 Gy) was rescaled based on dose constraints for the lung, spinal cord, esophagus, brachial plexus, and heart. The effect on tumor total dose (TTD) and biologic tumor effective dose in 2-Gy fractions (TED) corrected for overall treatment time (OTT) was compared for isotoxic and maximally tolerable schemes given in 15, 20, and 33 fractions. Rescaling was accomplished by altering the dose per fraction and/or the number of fractions while keeping the relative dose distribution of the original treatment plan. Results: For 30 of the 38 patients, dose escalation by individualized hypofractionation yielded therapeutic gain. For the maximally tolerable dose scheme in 33 fractions (MTD{sub 33}), individualized dose escalation resulted in a 2.5-21% gain in TTD. In the isotoxic schemes, the number of fractions could be reduced with a marginal increase in TED. For the maximally tolerable dose schemes, the TED could be escalated up to 36.6%, and for all patients beyond the level of the isotoxic and the MTD{sub 33} schemes (range, 3.3-36.6%). Reduction of the OTT contributed to the therapeutic gain of the shortened schemes. For the maximally tolerable schemes, the maximum esophageal dose was the dominant dose-limiting constraint in most patients. Conclusions: This modeling study showed that individualized dose prescription for hypofractionation in NSCLC radiotherapy, based on scaling of existing treatment plans up to normal tissue dose constraints, enables dose escalation with therapeutic gain in 79% of the cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Elective Lymph Node Irradiation With Intensity-Modulated Radiotherapy: Is Conventional Dose Fractionation Necessary?

Purpose: Intensity-modulated radiation therapy (IMRT) is the standard of care for head-and-neck cancer (HNC). We treated patients with HNC by delivering either a moderate hypofractionation (MHF) schedule (66 Gy at 2.2 Gy per fraction to the gross tumor [primary and nodal]) with standard dose fractionation (54-60 Gy at 1.8-2.0 Gy per fraction) to the elective neck lymphatics or a conventional dose and fractionation (CDF) schedule (70 Gy at 2.0 Gy per fraction) to the gross tumor (primary and nodal) with reduced dose to the elective neck lymphatics. We analyzed these two cohorts for treatment outcomes. Methods and Materials: Between November 2001 and February 2009, 89 patients with primary carcinomas of the oral cavity, larynx, oropharynx, hypopharynx, and nasopharynx received definitive IMRT with or without concurrent chemotherapy. Twenty patients were treated using the MHF schedule, while 69 patients were treated with the CDF schedule. Patient characteristics and dosimetry plans were reviewed. Patterns of failure including local recurrence (LR), regional recurrence (RR), distant metastasis (DM), disease-free survival (DFS), overall survival (OS), and toxicities, including rate of feeding tube placement and percentage of weight loss, were reviewed and analyzed. Results: Median follow-up was 31.2 months. Thirty-five percent of patients in the MHF cohort and 77% of patients in the CDF cohort received chemotherapy. No RR was observed in either cohort. OS, DFS, LR, and DM rates for the entire group at 2 years were 89.3%, 81.4%, 7.1%, and 9.4%, respectively. Subgroup analysis showed no significant differences in OS (p = 0.595), DFS (p = 0.863), LR (p = 0.833), or DM (p = 0.917) between these two cohorts. Similarly, no significant differences were observed in rates of feeding tube placement and percentages of weight loss. Conclusions: Similar treatment outcomes were observed for MHF and CDF cohorts. A dose of 50 Gy at 1.43 Gy per fraction may be sufficient to electively treat low-risk neck lymphatics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Application of a Novel Hybrid Intensity-Modulated Radiotherapy Technique for Stage III Lung Cancer and Dosimetric Comparison With Four Other Techniques

Purpose: In large stage III lung tumors, planning delivery of doses exceeding 60 Gy can be challenging and time consuming. Intensity modulated radiation therapy (IMRT) can improve target coverage but may increase volumes receiving low-dose irradiation. We clinically implemented a novel hybrid IMRT (h-IMRT) technique that allowed plans to be produced quickly, and compared these plans with 4 other techniques. Methods and Materials: h-IMRT was used to treat 14 consecutive patients with planning target volumes (PTVs) exceeding 500 cm{sup 3} (average, 779 cm{sup 3}) with concurrent chemo-radiation therapy to 66 Gy. h-IMRT plans consisted of 2 components: an anterior-posterior/posterior-anterior/posterior-anterior (AP-PA-PA) oblique, open-field technique delivering an average dose of 58 Gy, plus a 3-field IMRT component optimized to achieve a final homogeneous dose of 66 Gy. Total lung V{sub 20} and contralateral lung V{sub 5} were kept as low as possible but preferably less than 35% and less than 50%, respectively. All plans were retrospectively replanned using a 5- to 9-field 3-dimensional conformal technique, full RapidArc, 6-field full IMRT, and a hybrid RapidArc (h-RapidArc) technique similar to the h-IMRT. Results: The h-IMRT, h-RapidArc, and full RapidArc plans could be generated in less than 2 h, with the first 2 plans achieving the lowest V{sub 5} (36%) and V{sub 20} (30%) values together with the smallest hot spots. Both the 3-dimensional conformal and full IMRT plans occasionally led to unacceptable hot spots outside the PTV. Full RapidArc plans were fast and achieved comparable V{sub 20} values but led to slightly higher V{sub 5} values. Conclusions: Both h-IMRT and h-RapidArc permitted delivery of 66 Gy to large stage III lung tumors, and both were superior to either full IMRT or RapidArc plans for reducing lung doses. The clinical significance of small increases in V{sub 5} during chemo-radiation therapy delivery are unknown, but the present study suggests that h-IMRT and h-RapidArc are preferable for treatment of large tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated Volumetric Modulated Arc Therapy Treatment Planning for Stage III Lung Cancer: How Does It Compare With Intensity-Modulated Radio Therapy?

Purpose: To compare the quality of volumetric modulated arc therapy (VMAT) or intensity-modulated radiation therapy (IMRT) plans generated by an automated inverse planning system with that of dosimetrist-generated IMRT treatment plans for patients with stage III lung cancer. Methods and Materials: Two groups of 8 patients with stage III lung cancer were randomly selected. For group 1, the dosimetrists spent their best effort in designing IMRT plans to compete with the automated inverse planning system (mdaccAutoPlan); for group 2, the dosimetrists were not in competition and spent their regular effort. Five experienced radiation oncologists independently blind-reviewed and ranked the three plans for each patient: a rank of 1 was the best and 3 was the worst. Dosimetric measures were also performed to quantitatively evaluate the three types of plans. Results: Blind rankings from different oncologists were generally consistent. For group 1, the auto-VMAT, auto-IMRT, and manual IMRT plans received average ranks of 1.6, 2.13, and 2.18, respectively. The auto-VMAT plans in group 1 had 10% higher planning tumor volume (PTV) conformality and 24% lower esophagus V70 (the volume receiving 70 Gy or more) than the manual IMRT plans; they also resulted in more than 20% higher complication-free tumor control probability (P+) than either type of IMRT plans. The auto- and manual IMRT plans in this group yielded generally comparable dosimetric measures. For group 2, the auto-VMAT, auto-IMRT, and manual IMRT plans received average ranks of 1.55, 1.75, and 2.75, respectively. Compared to the manual IMRT plans in this group, the auto-VMAT plans and auto-IMRT plans showed, respectively, 17% and 14% higher PTV dose conformality, 8% and 17% lower mean lung dose, 17% and 26% lower mean heart dose, and 36% and 23% higher P+. Conclusions: mdaccAutoPlan is capable of generating high-quality VMAT and IMRT treatment plans for stage III lung cancer. Manual IMRT plans could achieve quality similar to auto-IMRT plans if best effort was spent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Normal Tissue Anatomy for Oropharyngeal Cancer: Contouring Variability and Its Impact on Optimization

Purpose: To evaluate the variability of organ at risk (OAR) delineation and the resulting impact on intensity modulated radiation therapy (IMRT) treatment plan optimization in head-and-neck cancer. Methods and Materials: An expert panel of 3 radiation oncologists jointly delineated OARs, including the parotid and submandibular glands (SM), pharyngeal constrictors (PC), larynx, and glottis (GL), in 10 patients with advanced oropharynx cancer in 3 contouring sessions, spaced at least 1 week apart. Contour variability and uncertainty, as well as their dosimetric impact on IMRT planning for each case, were assessed. Results: The mean difference in total volume for each OAR was 1 cm{sup 3} ({sigma} 0.5 cm{sup 3}). Mean fractional overlap was 0.7 ({sigma} 0.1) and was highest (0.8) for the larynx and bilateral SMs and parotids and lowest (0.5) for PC. There were considerable spatial differences in contours, with the ipsilateral parotid and PC displaying the most variability (0.9 cm), which was most prominent in cases in which tumors obliterated fat planes. Both SMs and GL had the smallest differences (0.5 cm). The mean difference in OAR dose was 0.9 Gy (range 0.6-1.1 Gy, {sigma} 0.1 Gy), with the smallest difference for GL and largest for both SMs and the larynx. Conclusions: Despite substantial difference in OAR contours, optimization was barely affected, with a 0.9-Gy mean difference between optimizations, suggesting relative insensitivity of dose distributions for IMRT of oropharynx cancer to the extent of OARs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗