Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Overestimations in zero frequency DQE of x-ray imaging converters assessed by Monte Carlo techniques based on the study of energy impartation events

Purpose: The performance of various x-ray converters, employed in medical imaging systems, has been widely examined by several methodologies (experimental, analytical, and Monte Carlo techniques). The x-ray converters most frequently employed in energy integrating digital radiology detectors are the Gd{sub 2}O{sub 2}S:Tb granular phosphor, the CsI:Tl structured phosphor, and the a-Se photoconductor. The imaging characteristics of an x-ray converter are affected by its x-ray detection properties. However, various definitions of x-ray detection have been used in the literature, leading to different results for the quantum detection efficiency (QDE) for the same type of x-ray converter. For this reason, there is a need for accurate determination of the x-ray detection and, in particular, its relation to detector response. Methods: The present article reports on the performance of the three aforementioned x-ray converters in terms of the QDE and the x-ray statistical factor I{sub x} and examines the effect of the x-ray detection, directly related to converter output signal, on the zero-frequency DQE. For the purposes of this study, Monte Carlo simulation was used to model the x-ray interactions within the x-ray converter. Simulations were carried out in the energy range from 10 keV up to 80 keV and considering two layers of different coating weights (50 and 100 mg/cm{sup 2}). The prediction and comparison of zero-frequency DQE were based on two different approaches for x-ray detection, i.e., (a) fraction of interacting photons and (b) fraction of photons leading to energy deposition. In addition, the effect of energy deposition through Compton scattering events on the DQE values was estimated. Results: Our results showed discrepancies between Monte Carlo techniques (based on energy deposition events) and analytical calculations (based on x-ray attenuation) on QDE. Discrepancies were found to range up to 10% for Gd{sub 2}O{sub 2}S:Tb (100 mg/cm{sup 2}), 7.7% for CsI:Tl (50 mg/cm{sup 2}), and 8.2% for a-Se (50 mg/cm{sup 2}). Discrepancies were analyzed by examining the scattering effects (elastic and inelastic) within the converters and led to further analysis of scattering events on I{sub x} as well. Significant overestimations were found for both factors (QDE and I{sub x}) on the zero-frequency DQE. Conclusions: Considering that the highest overestimation was found in the thin layer (50 mg/cm{sup 2}), Monte Carlo evaluation showed that the overestimation (%) between DQE values (based on either x-ray interacting events or energy impartation events) was more significant at 20 keV for CsI:Tl (approximately 2.1%), at 40 keV for Gd{sub 2}O{sub 2}S:Tb (approximately 8.1%), and finally at 60 and 80 keV for a-Se converter (approximately 4.8 and 8.2%, respectively). Finally, the overestimation due to the effect of Compton scattering on DQE was found more significant for the a-Se converter and especially above 40 keV reaching approximately the value of 8.9% at 80 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances and future needs in particle production and transport code developments

The next generation of accelerators and ever expanding needs of existing accelerators demand new developments and additions to Monte-Carlo codes, with an emphasis on enhanced modeling of elementary particle and heavy-ion interactions and transport. Challenges arise from extremely high beam energies and beam power, increasing complexity of accelerators and experimental setups, as well as design, engineering and performance constraints. All these put unprecedented requirements on the accuracy of particle production predictions, the capability and reliability of the codes used in planning new accelerator facilities and experiments, the design of machine, target and collimation systems, detectors and radiation shielding and minimization of their impact on environment. Recent advances in widely-used general-purpose all-particle codes are described for the most critical modules such as particle production event generators, elementary particle and heavy ion transport in an energy range which spans up to 17 decades, nuclide inventory and macroscopic impact on materials, and dealing with complex geometry of accelerator and detector structures. Future requirements for developing physics models and Monte-Carlo codes are discussed.

43 PARTICLE ACCELERATORS↗

The Low Energy Neutrino Factory

We show that a low energy neutrino factory with a baseline of 1300 km and muon energy of 4.5 GeV has an excellent physics reach. The results of our optimisation studies demonstrate that such a setup can have remarkable sensitivity to theta{sub 13} and delta for sin{sup 2}(2theta{sub 13})>10{sup -4}, and to the mass hierarchy for sin{sup 2}(2theta{sub 13})>10{sup -3}. We also illustrate the power of the unique combination of golden and platinum channels accessible to the low energy neutrino factory. We have considered both a 20 kton totally active scintillating detector and a 100 kton liquid argon detector as possible detector technologies, finding that a liquid argon detector with very good background rejection can produce sensitivity to theta{sub 13} and delta with that of the International Design Study neutrino factory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of the top-quark mass using charged particle tracking

We present three measurements of the top-quark mass in the lepton plus jets channel with approximately 1.9 fb{sup -1} of integrated luminosity collected with the CDF II detector using quantities with minimal dependence on the jet energy scale. One measurement exploits the transverse decay length of b-tagged jets to determine a top-quark mass of 166.9{sub -8.5}{sup +9.5}(stat){+-}2.9(syst) GeV/c{sup 2}, and another the transverse momentum of electrons and muons from W-boson decays to determine a top-quark mass of 173.5{sub -8.9}{sup +8.8}(stat){+-}3.8(syst) GeV/c{sup 2}. These quantities are combined in a third, simultaneous mass measurement to determine a top-quark mass of 170.7{+-}6.3(stat){+-}2.6(syst) GeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New color-octet axial vector boson revisited

In this paper we reexamine how to utilize the previous proposed color-octet axial-vector boson Z{sub C} to explain the 3.4{sigma} anomaly of tt forward-backward (FB) asymmetry A{sub FB} for m{sub tt}>450 GeV observed by CDF. Our numerical results indicate that the best-fit parameters are g{sub A}{sup q}=0.07, g{sub A}{sup Q}=3, and M{sub C}=440 GeV, which are obtained by fitting the mass dependent A{sub FB} and total cross section data provided by a recent CDF measurement. Here g{sub A}{sup q}(g{sub A}{sup Q}) and M{sub C} are the axial couplings among Z{sub C} with the first two (the third) generation quarks, and Z{sub C} mass, respectively. We also calculate one-side forward-backward asymmetry A{sub OFB} for top and bottom quark pair production at the LHC, focusing on the new contributions from Z{sub C}. Our studies show that A{sub OFB} can be utilized to measure the properties of new particle Z{sub C}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deuterium-tritium neutron yield measurements with the 4.5 m neutron-time-of-flight detectors at NIF

The first several campaigns of laser fusion experiments at the National Ignition Facility (NIF) included a family of high-sensitivity scintillator/photodetector neutron-time-of-flight (nTOF) detectors for measuring deuterium-deuterium (DD) and DT neutron yields. The detectors provided consistent neutron yield (Y{sub n}) measurements from below 10{sup 9} (DD) to nearly 10{sup 15} (DT). The detectors initially demonstrated detector-to-detector Y{sub n} precisions better than 5%, but lacked in situ absolute calibrations. Recent experiments at NIF now have provided in situ DT yield calibration data that establish the absolute sensitivity of the 4.5 m differential tissue harmonic imaging (DTHI) detector with an accuracy of {+-}10% and precision of {+-}1%. The 4.5 m nTOF calibration measurements also have helped to establish improved detector impulse response functions and data analysis methods, which have contributed to improving the accuracy of the Y{sub n} measurements. These advances have also helped to extend the usefulness of nTOF measurements of ion temperature and downscattered neutron ratio (neutron yield 10-12 MeV divided by yield 13-15 MeV) with other nTOF detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital front-end electronics for a tagged neutron inspection system

In this paper, we shall present a simple VME front-end system that employs the FADC CAEN V1720 8- channel 12-bit 250-MS/s digitizer. This system produces coincidence spectra between the trigger particle and other detectors and it replaces the traditional technique of chaining analog electronics. Tests have been performed using a pulser working at different frequencies as well as employing a {sup 252}Cf source in concert with an array of detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Global Analysis of Light and Charge Yields in Liquid Xenon

Here, we present an updated model of light and charge yields from nuclear recoils in liquid xenon with a simultaneously constrained parameter set. A global analysis is performed using measurements of electron and photon yields compiled from all available historical data, as well as measurements of the ratio of the two. These data sweep over energies from keV and external applied electric fields from V/cm. The model is constrained by constructing global cost functions and using a simulated annealing algorithm and a Markov Chain Monte Carlo approach to optimize and find confidence intervals on all free parameters in the model. This analysis contrasts with previous work in that we do not unnecessarily exclude datasets nor impose artificially conservative assumptions, do not use spline functions, and reduce the number of parameters used in NEST v 0.98. Here, we report our results and the calculated best-fit charge and light yields. These quantities are crucial to understanding the response of liquid xenon detectors in the energy regime important for rare event searches such as the direct detection of dark matter particles.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Heavy hadron spectroscopy at CDF

We present recent CDF results on the properties of hadrons containing heavy quarks. These include measurements of charm and {Sigma}{sub b}{sup -}{Sigma}*{sub b}{sup -} baryon's masses, lifetimes and masses of {Omega}{sub b}{sup -}, {Xi}{sub b}{sup -} and B{sub c}{sup -} and a measurement of exclusive B{sup +}, B{sup 0} and {Lambda}{sub b} lifetimes as well as lifetime ratios (charge conjugate modes are implied throughout the text). We also summarize new measurements of exotic particles X(3872) and Y(4140).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Forward-backward asymmetry of the top quark in diquark models

Motivated by the recent unexpected large forward-backward asymmetry of the top-quark observed by D0 and CDF at the Tevatron, we investigate a possible explanation for the anomaly within the framework of diquark models. In the diquark models, the top-quark pair production is mediated by the u-channel diagram. It is found that the color-triplet diquark can generate the forward-backward asymmetry of 20% when the constraint from the cross section of the top-quark pair production is taken into account.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gravitational waves from extreme mass-ratio inspirals in dynamical Chern-Simons gravity

Dynamical Chern-Simons gravity is an interesting extension of general relativity, which finds its way in many different contexts, including string theory, cosmological settings, and loop quantum gravity. In this theory, the gravitational field is coupled to a scalar field by a parity-violating term, which gives rise to characteristic signatures. Here we investigate how Chern-Simons gravity would affect the quasicircular inspiralling of a small, stellar-mass object into a large nonrotating supermassive black hole, and the accompanying emission of gravitational and scalar waves. We find the relevant equations describing the perturbation induced by the small object, and we solve them through the use of Green's function techniques. Our results show that for a wide range of coupling parameters, the Chern-Simons coupling gives rise to an increase in total energy flux, which translates into a fewer number of gravitational-wave cycles over a certain bandwidth. For space-based gravitational-wave detectors such as LISA, this effect can be used to constrain the coupling parameter effectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Energy Performance Tests of Large Volume LaBr{sub 3}:Ce Detector

High energy prompt gamma ray tests of a large volume cylindrical 100 mm x 100 mm (height x diameter) LaBr{sub 3}:Ce detector were carried out using a portable neutron generator-based Prompt Gamma Neutron Activation Analysis (PGNAA) setup. In this study prompt gamma-rays yield were measured from water samples contaminated with toxic elements such nickel, chromium and mercury compounds with gamma ray energies up to 10 MeV. The experimental yield of prompt gamma-rays from toxic elements were compared with the results of Monte Carlo calculations. In spite of its higher intrinsic background due to its larger volume, an excellent agreement between the experimental and calculated yields of high energy gamma-rays from Ni, Cr and Hg samples has been achieved for the large volume LaBr{sub 3}:Ce detector. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high-speed one-dimensional detector for time-resolved small -angle X-ray scattering : design and characterization.

A high-speed one-dimensional detector for time-resolved small-angle x-ray scattering has been designed and built for experiments at the Advanced Photon Source of Argonne National Laboratory. This detector is made from a 500-?m thick by 150-mm diameter ultra-high-purity n-type silicon wafer. The electrodes, which are a series of concentric rings that are deposited in the wafer, integrate the scattered x-rays over the azimuthal angle and, thereby, produce a one-dimensional detector. This design yields 128 rings, which allows parallel processing of the signal from each ring. The readout electronics consist of transimpedance front-end amplifiers, one for each ring, followed by active pulse-shaping filters. The amplifier signals are digitized using 12-bit analog-to-digital converters, one per ring, which operate at 20 MHz. The frame rate of the system is 271 kHz. Up to 220 - 1 scattering profiles may be stored on a random access memory chip and transferred to a data file at a rate of 16 x 103 profiles/sec. For X-ray energies between 3.5 and 13.2 keV the efficiency exceeds 80%. The resolving time of the electronics is 300 ns, which is sufficient to isolate electronically a single pulse of scattered x-rays when the synchrotron is operated in a hybrid or asymmetric fill pattern. Therefore, laser-pump/x-ray-probe experiments can be performed without a mechanical shutter. Examples of time-resolved speckle and the kinetics of the formation of sodium chloride particles are presented. This detector is capable of acquiring small-angle x-ray scattering profiles over multiple time scales, which are needed to characterize many chemical, physical, and biological processes. In addition, this detector may be tested and calibrated before experimental runs, without access to an intense beam of x-rays, with alpha particles from a radioactive source such as 241Am.

43 PARTICLE ACCELERATORS↗

Source localization using multiple units of a tight-pitched detector array

A system and method for determining a probability of the location of an illicit radiation source within an environment based on directional detectors. An embodiment includes a plurality of directional radiation detectors distributed about the environment and integrated with a processing unit adapted to determine the probability of the source location based on the radiation count data received from the plurality of detectors. The processing unit is further adapted to output information indicative of the location of the radiation source within the environment.

Vilim, Richard B.↗