Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QUALITY FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Using Remote Sensing Mapping and Growth Response to Environmental Variability to Aide Aquatic Invasive Plant Management

Management of aquatic weeds in complex watersheds and river systems present many challenges to assessment, planning and implementation of management practices for floating and submerged aquatic invasive plants. The Delta Region Areawide Aquatic Weed Project (DRAAWP), a USDA sponsored area-wide project, is working to enhance planning, decision-making and operational efficiency in the California Sacramento-San Joaquin Delta. Satellite and airborne remote sensing are used map (area coverage and biomass density), direct operations, and assess management impacts on plant communities. Archived satellite records enable review of results following previous climate and management events and aide in developing long-term strategies. Examples of remote sensing aiding effectiveness of aquatic weed management will be discussed as well as areas for potential technological improvement. Modeling at local and watershed scales using the SWAT modeling tool provides insight into land-use effects on water quality (described by Zhang in same Symposium). Controlled environment growth studies have been conducted to quantify the growth response of invasive aquatic plants to water quality and other environmental factors. Environmental variability occurs across a range of time scales from long-term climate and seasonal trends to short-term water flow mediated variations. Response time for invasive species response are examined at time scales of weeks, day, and hours using a combination of study duration and growth assessment techniques to assess water quality, temperature (air and water), nitrogen, phosphorus, and light effects. These provide response parameters for plant growth models in response to the variation and interact with management and economic models associated with aquatic weed management. Plant growth models are to be informed by remote sensing and applied spatially across the Delta to balance location and type of aquatic plant, growth response to altered environments and phenology. Initial utilization of remote sensing tools developed for mapping of aquatic invasive plants improved operational efficiency in management practices. These assessment methods provide a comprehensive and quantitative view of aquatic invasive plants communities in the California Delta.

Remote Sensing↗

Patient-Reported Voice and Speech Outcomes After Whole-Neck Intensity Modulated Radiation Therapy and Chemotherapy for Oropharyngeal Cancer: Prospective Longitudinal Study

Purpose: To describe voice and speech quality changes and their predictors in patients with locally advanced oropharyngeal cancer treated on prospective clinical studies of organ-preserving chemotherapy–intensity modulated radiation therapy (chemo-IMRT). Methods and Materials: Ninety-one patients with stage III/IV oropharyngeal cancer were treated on 2 consecutive prospective studies of definitive chemoradiation using whole-field IMRT from 2003 to 2011. Patient-reported voice and speech quality were longitudinally assessed from before treatment through 24 months using the Communication Domain of the Head and Neck Quality of Life (HNQOL-C) instrument and the Speech question of the University of Washington Quality of Life (UWQOL-S) instrument, respectively. Factors associated with patient-reported voice quality worsening from baseline and speech impairment were assessed. Results: Voice quality decreased maximally at 1 month, with 68% and 41% of patients reporting worse HNQOL-C and UWQOL-S scores compared with before treatment, and improved thereafter, recovering to baseline by 12-18 months on average. In contrast, observer-rated larynx toxicity was rare (7% at 3 months; 5% at 6 months). Among patients with mean glottic larynx (GL) dose ≤20 Gy, >20-30 Gy, >30-40 Gy, >40-50 Gy, and >50 Gy, 10%, 32%, 25%, 30%, and 63%, respectively, reported worse voice quality at 12 months compared with before treatment (P=.011). Results for speech impairment were similar. Glottic larynx dose, N stage, neck dissection, oral cavity dose, and time since chemo-IMRT were univariately associated with either voice worsening or speech impairment. On multivariate analysis, mean GL dose remained independently predictive for both voice quality worsening (8.1%/Gy) and speech impairment (4.3%/Gy). Conclusions: Voice quality worsening and speech impairment after chemo-IMRT for locally advanced oropharyngeal cancer were frequently reported by patients, underrecognized by clinicians, and independently associated with GL dose. These findings support reducing mean GL dose to as low as reasonably achievable, aiming at ≤20 Gy when the larynx is not a target.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Crystallographic model quality at a glance

A crystallographic macromolecular model is typically characterized by a list of quality criteria, such as R factors, deviations from ideal stereochemistry and average B factors, which are usually provided as tables in publications or in structural databases. In order to facilitate a quick model-quality evaluation, a graphical representation is proposed. Each key parameter such as R factor or bond-length deviation from ‘ideal values’ is shown graphically as a point on a ‘ruler’. These rulers are plotted as a set of lines with the same origin, forming a hub and spokes. Different parts of the rulers are coloured differently to reflect the frequency (red for a low frequency, blue for a high frequency) with which the corresponding values are observed in a reference set of structures determined previously. The points for a given model marked on these lines are connected to form a polygon. A polygon that is strongly compressed or dilated along some axes reveals unusually low or high values of the corresponding characteristics. Polygon vertices in ‘red zones’ indicate parameters which lie outside typical values.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Critical Review of LPBF Metal Print Defects Detection: Roles of Selective Sensing Technology

The integrative potential of LPBF-printed parts for various innovative applications depends upon the robustness and infallibility of the part quality. Eliminating or sufficiently reducing factors contributing to the formation of defects is an integral step to achieving satisfiable part quality. Significant research efforts have been conducted to understand and quantify the triggers and origins of LPBF defects by investigating the material properties and process parameters for LPBF-printed geometries using various sensing technologies and techniques. Frequently, combinations of sensing techniques are applied to deepen the understanding of the investigated phenomena. The main objectives of this review are to cover the roles of selective sensing technologies by (1) providing a summary of LPBF metal print defects and their corresponding causes, (2) informing readers of the vast number and types of technologies and methodologies available to detect defects in LPBF-printed parts, and (3) equipping readers with publications geared towards defect detection using combinations of sensing technologies. Due to the large pool of developed sensing technology in the last few years for LPBF-printed parts that may be designed for targeting a specific defect in metal alloys, the article herein focuses on sensing technology that is common and applicable to most common defects and has been utilized in characterization for an extended period with proven efficiency and applicability to LPBF metal parts defect detection.

36 MATERIALS SCIENCE↗

Experimental investigation of the quality characteristics of agricultural plastic wastes regarding their recycling and energy recovery potential

Highlights: Black-Right-Pointing-Pointer Definition of parameters characterising agricultural plastic waste (APW) quality. Black-Right-Pointing-Pointer Analysis of samples to determine APW quality for recycling or energy recovery. Black-Right-Pointing-Pointer Majority of APW samples from various countries have very good quality for recycling. Black-Right-Pointing-Pointer Upper limit of 50% w/w soil contamination in APW acceptable for energy recovery. Black-Right-Pointing-Pointer Chlorine and heavy metals content in APW below the lowest limit for energy recovery. - Abstract: A holistic environmentally sound waste management scheme that transforms agricultural plastic waste (APW) streams into labelled guaranteed quality commodities freely traded in open market has been developed by the European research project LabelAgriWaste. The APW quality is defined by the APW material requirements, translated to technical specifications, for recycling or energy recovery. The present work investigates the characteristics of the APW quality and the key factors affecting it from the introduction of the virgin product to the market to the APW stream reaching the disposer. Samples of APW from different countries were traced from their application to the field through their storage phase and transportation to the final destination. The test results showed that the majority of APW retained their mechanical properties after their use preserving a 'very good quality' for recycling in terms of degradation. The degree of soil contamination concerning the APW recycling and energy recovery potential fluctuates depending on the agricultural plastic category and application. The chlorine and heavy metal content of the tested APW materials was much lower than the maximum acceptable limits for their potential use in cement industries.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

From Deposition to Encapsulation: Roll-to-roll manufacturing of organic light emitting devices for lighting (Final Report)

Organic light emitting devices (OLEDs) are promising solid state light sources due to their high efficiency, high color quality and flexible form factors. The key to enable low cost OLED lighting, is to rapidly fabricate thin film organic layers on a continuous flexible roll, called R2R processing. This project aims to investigate the feasibility of mass production of OLED lighting using the R2R process, from deposition to encapsulation. A high efficiency white OLED is fabricated on 10 cm-wide substrate rolls in a pilot R2R tool comprising of two different organic deposition: vacuum thermal evaporation (VTE) and organic vapor phase deposition (OVPD). A high quality encapsulation process to package OLEDs is demonstrated using an atomic layer deposition tool integrated to the R2R system without air exposure. The method to achieve ultrahigh deposition rates required by R2R processing is demonstrated by OVPD. Uniform organic semiconductor thin films grown by OVPD at rates as high as 50 Å/s are achieved. A comprehensive numerical model that is capable of simulating complex, multilayer WOLED structures is developed to provide an alternative to experimental iterations of OLED design and tests. A cost estimate on the R2R production of WOLEDs for lighting is developed. Assuming a WOLED luminance of 10 klm/m 2 , the cost of a WOLED light engine is anticipated to be $\$ 12.5$ /klm. With incremental reduction in material and driver costs and improved luminance, the cost of WOLED lighting can be reduced to $\$ 6.3$ /klm in the near term. These findings suggest OLED lighting can be volume manufactured by R2R vapor deposition methods with much reduced costs compared to current batch processing methods, potentially positioning WOLEDs for use in numerous premium lighting applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Vertical Ozone Profile Comparisons Between Ozonesondes and Remote Instrumentation

Ozonesonde measurement quality is a critical factor for insuring measurement accuracy and is fundamentally indispensable for validating remotely measured ozone. Reasonable results from such ozone profile comparisons are best obtained by maintaining the smallest possible spatial and time differences between ozonesonde and remote measurement observations. Ozone profiles measured with the Halogen Occultation Experiment (HALOE) instrument and the Microwave Limb Sounder (MLS) instrument on NASA's Upper Atmosphere Research Satellite (UARS) are compared with ECC profiles. Comparisons with the GSFC ozone lidar also demonstrate good agreement. In this paper we show: (1) the process used by NASA to secure quality ozonesonde measurements, (2) comparisons of ozonesondes with various remote sensing instruments and, (3) the reliability obtained when both measurement types are obtained close in time and, when possible, in space.

Schmidlin, F. J.↗

Environmental Justice Needs-Assessment For Health & Air Quality: Assessing the Needs and Capacity of Organizations Working Towards Health and Environmental Justice Related to Health and Air Quality

Health and air quality are concerns in environmental justice (EJ) work, as air contaminants and their adverse health effects inequitably impact communities that are often underrepresented in research and litigation. Previously, the NASA DEVELOP National Program partnered with organizations that focus on a variety of health and air quality concerns and is now committed to partnering directly with EJ organizations to address inequities in health and air quality through the application of Earth observations. To support the establishment of future partnerships, DEVELOP is working to identify potential partners for further EJ research in the U.S. regarding health and air quality. This project conducted a needs assessment with EJ organizations to quantify their EJ involvement, geospatial capacity, and interest in collaborating with DEVELOP. A broad literature review identified multiple factors influencing health and air quality for potential DEVELOP projects: agriculture, heat, wildfires, industry and transportation infrastructure, and miscellaneous factors (e.g., burning, urban heat island effect, smoke plumes, truck exhaust, and noise). The needs assessment showed that 22% of the organizations interviewed were primarily concerned with transportation infrastructure, 21% with industry, 19% with heat, 10% with miscellaneous factors (e.g., resource mining, COVID-19), 8% with wildfires, 7% with agriculture, and 6% with resource mining. This will help inform the DEVELOP Program's pursuit of EJ projects relating to health and air quality. The team also created a directory for communities impacted by air pollutants to connect with geospatial resources and NASA Applied Sciences personnel for future EJ health and air quality work.

Elizabeth Duran↗

FY 2018 ARM Radar Plan

The fundamental objective of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility radar facility is to provide high-quality radar observations to the scientific user community with an overarching goal of improving the treatment of clouds and precipitation in climate models. Historically, ARM has operated zenith-profiling cloud radars at millimeter wavelengths at five of its facilities. Since 2010, 16 scanning systems have been added to the radar facility. The ARM radar facility has 33 radars in its possession at three fixed sites and three mobile facilities. A breakdown of the ARM radar assets is given below: 8 Scanning ARM Clouds Radar Systems (SACR: two radars on single pedestal; six 1st- and two 2nd- generation) 7 Ka-band ARM Zenith profiling Radar (KAZR: five 1st- and two 2nd-generation) 5 X-band Scanning ARM precipitation Radar (XSAPR: four 1st- and one 2nd-generation) 3 C-band Scanning ARM precipitation Radar (CSAPR: two 1st- and one 2nd-generation) 1 W-band ARM Cloud Radar (WACR) 1 Marine W-band ARM Cloud Radar (MWACR: configured to be deployed on a stable table or scanning pedestal). Of these radars, all but six (two SACRs [accounting for four radars], one KAZR, and one 1st-generation CSAPR) have operational assignments. Therefore, the current measurement strategy involves operating 27 radars, not including radar wind profilers (RWPs). This array of instruments represents a combination of scanning and profiling radars at ARM’s sites. In addition to the scanning capabilities, the radars at each site differ in operating frequency, technology, and complexity, but all are complex systems. Some of them were custom designed and built specifically for ARM. Typically, newer systems take a few years to reach operational maturity with adequate characterization, calibration, testing, and quality control. Due to various factors, not all of the radars have achieved an operationally mature status sufficient to provide high-quality data in a research environment. In addition, these radars are often deployed in remote locations and harsh environments to meet science needs. The remoteness of such complex systems is a considerable challenge for continuous operations. Tools needed for a research-level operational radar are not readily available from vendors, and many of the necessary system management tools, both hardware and software, to manage these systems must be developed in-house for such deployments. Based on experience over the past seven years, including conclusions from the first phase of the radar plan, implemented in mid-2016, it is clear that ARM cannot support the operation of all 27 currently deployed radars and expect to provide research-quality data (including higher-order products) with the current resources. Experience from the first phase of the radar plan has provided a better indication than has been available previously of what size radar network is reasonable. A preliminary proposal for what that radar network could look like is provided here. The plan presented here uses the available resources to best support this proposed network.

ARM Mobile Facility↗

Investigation of an Ultrafast Harmonic Resonant RF Kicker

An Energy Recovery Linac (ERL) based multi-turn electron Circulator Cooler Ring (CCR) is envisaged in the proposed Jefferson Lab Electron Ion Collider (JLEIC) to cool the ion bunches with high energy (55 MeV), high current (1.5 A), high repetition frequency (476.3 MHz), high quality magnetized electron bunches. A critical component in this scheme is a pair of ultrafast kickers for the exchange of electron bunches between the ERL and the CCR. The ultrafast kicker should operate with the rise and fall time in less than 2.1 ns, at the repetition rate of ~10s MHz, and should be able to run continuously during the whole period of cooling. These -and-fall time being combined together, are well beyond the state-of-art of traditional pulsed power supplies and magnet kickers. To solve this technical challenge, an alternative method is to generate this high repetition rate, fast rise-and-fall time short pulse continuous waveform by summing several finite number of (co)sine waves at harmonic frequencies of the kicking repetition frequency, and these harmonic modes can be generated by the Quarter Wave Resonater (QWR) based multifrequency cavities. Assuming the recirculator factor is 10, 10 harmonic modes (from 47.63 MHz to 476.3 MHz) with proper amplitudes and phases, plus a DC offset are combined together, a continuous short pulse waveform with the rise-and-fall time in less than 2.1 ns, repetition rate of 47.63 MHz waveform can be generated. With the compact and matured technology of QWR cavities, the total cost of both hardware development and operation can be reduced to a modest level. Focuse on the technical scheme, three main topics will be discussed in this thesis: the synthetization of the kicking pulse, the design and optimization of the deflecting QWR multi-integer harmonic frequency resonator and the fabrication and bench measurements of a half scale copper prototype. In the kicking pulse synthetization part, we begin with the Fourier Series expansion of an ideal square pulse, and get a Flat-Top waveform which will give a uniform kick over the bunch length of the kicked electron bunches, thus the transverse emittance of these kicked electron bunches can be maintained. By using two identical kickers with the betatron phase advance of 180 degree or its odd multiples, the residual kick voltage wave slopes at the unkicked bunch position will be totally cancelled out. Flat-Top waveform combined with two kicker scheme, the transverse emittance of the cooling electron bunches will be conserved during the whole injection, recirculation, and ejection processes. In the cavity design part, firstly, the cavity geometry is optimized to get high transverse shunt impedance thus less than 100 W of RF losses on the cavity wall can be achieved for all these 10 harmonic modes. To support all these 10 harmonic modes, group of four QWRs are adopted with the mode distribution of 5:3:1:1. In the multi-frequency cavities such as the five-mode-cavity and the three-mode-cavity, tunings are required to achieve the design frequencies for each mode. Slight segments of taper design on the inner conductor help to get the frequencies to be exactly on the odd harmonic modes. Stub tuners equal to the number of resonant modes are inserted to the outer conductor wall to compensate the frequency shifts due manufacturing errors and other perturbations during the operation such as the change of the cavity temperature. Single loop couple is designed for all harmonic modes in each cavity. By adjusting its loop size, position and rotation, it is possible to get the fundamental mode critical coupled and other higher harmonic modes slightly over coupled. A broadband circulator will be considered for absorbing the reflected power. Finally in this part, multipole field components due to the asymmetric cylindrical structure around the beam axis of the cavity as well as the beam-induced higher order mode (HOM) issues will be analyzed and discussed in this thesis. A half-scale copper prototype cavity (resonant frequencies from 95.26 MHz to 857.34 MHz) was fabricated to validate the electromagnetic characteristics. With this half scale prototype, the tuning processes of multiple harmonic frequencies, unloaded quality factor measurements of each mode, and bead-pull measurements are performed. The bench measurement results matched well with the simulation results, which have validated our cavity design and construction methods. Finally, a simple mode combining experiment with five separate signal generators was performed on this prototype cavity and the desired fast rise/fall time (1.2 ns), high repetition rate (95.26 MHz) waveform was captured, which finally proved our design of this ultrafast harmonic kicker.

43 PARTICLE ACCELERATORS↗

Integrated Modeling of U.S. Agricultural Soil Emissions of Reactive Nitrogen and Associated Impacts on Air Pollution, Health, and Climate

Agricultural soils are leading sources of reactive nitrogen (Nr) species including nitrogen oxides (NO x ), ammonia (NH 3 ), and nitrous oxide (N 2 O). Here, the propensity of NO x and NH 3 to generate ozone and fine particulate matter (PM) and associated impacts on health are highly variable, whereas the climate impacts of long-lived N 2 O are independent of emission timing and location. However, these impacts have rarely been compared on a spatially-resolved, monetized basis. In this study, we update the nitrogen scheme in an agroecosystem model to simulate the agricultural emissions of Nr from across the United States. We then apply a reduced-form air pollution health effects model to assess air quality impacts from NO x and NH 3 and a social cost of N 2 O to assess the climate impacts. Assuming an $\$$8.2 million Value of a Statistical Life (VSL) and a $\$$13,100/ton social cost of N 2 O, the air quality impacts are a factor of ~7 to 15 times as large as the climate impacts in heavily populated coastal regions, whereas the ratios are closer to 2.5 in sparsely populated regions. Our results show that air pollution, health, and climate should be considered jointly in future assessments of how farming practices affect Nr emissions.

54 ENVIRONMENTAL SCIENCES↗

Weekly Verification of Dosimetric Data for Virtual Wedge Using a 2D Diode Detector Array

A linac manufacturer has recommended that users measure virtual wedge (VW) angle and VW factor as a weekly quality assurance (QA) procedure. The purpose of this study was to investigate whether a 2D diode detector array (MapCHECK{sup TM}) is a useful tool for the verification of dosimetric data for VW. Measurements were performed on 2 linear accelerators (4, 6, and 10 MV) at 10-cm depth for a field size of 10 x 10 cm{sup 2} and with wedge angles of 15, 30, 45, and 60{sup o}. To verify the VW dose distributions generated by the treatment planning system (TPS), we confirmed that agreement between TPS data and measurements were {<=}2% dose difference or 2-mm distance-to-agreement based on American Association of Physicists in Medicine Task Group Report 53 (AAPM TG-53). We present here the results of a 1-year evaluation of VW by means of a 2D diode detector array. The maximum 2-fold standard deviation of the measured wedge angle turned out to be within 1.0, and all measured VW factors to be 1.00 {+-} 0.03. Although >95% of the points measured for 6 and 10 MV were generally within the tolerance of the dose distribution as mentioned above, the percentage of agreement between the measured data for 4 MV and TPS data were somewhat below 90%. We also verified generally good reproducibility for the dose distribution. The 2-D diode detector array was thus found to be useful as a tool for weekly VW QA.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-J-41: Experimental Validation of a Cascaded Linear System Model for MVCBCT with a Multi-Layer EPID

Purpose: The purpose of this study was to validate the use of a cascaded linear system model for MV cone-beam CT (CBCT) using a multi-layer (MLI) electronic portal imaging device (EPID) and provide experimental insight into image formation. A validated 3D model provides insight into salient factors affecting reconstructed image quality, allowing potential for optimizing detector design for CBCT applications. Methods: A cascaded linear system model was developed to investigate the potential improvement in reconstructed image quality for MV CBCT using an MLI EPID. Inputs to the three-dimensional (3D) model include projection space MTF and NPS. Experimental validation was performed on a prototype MLI detector installed on the portal imaging arm of a Varian TrueBeam radiotherapy system. CBCT scans of up to 898 projections over 360 degrees were acquired at exposures of 16 and 64 MU. Image volumes were reconstructed using a Feldkamp-type (FDK) filtered backprojection (FBP) algorithm. Flat field images and scans of a Catphan model 604 phantom were acquired. The effect of 2×2 and 4×4 detector binning was also examined. Results: Using projection flat fields as an input, examination of the modeled and measured NPS in the axial plane exhibits good agreement. Binning projection images was shown to improve axial slice SDNR by a factor of approximately 1.4. This improvement is largely driven by a decrease in image noise of roughly 20%. However, this effect is accompanied by a subsequent loss in image resolution. Conclusion: The measured axial NPS shows good agreement with the theoretical calculation using a linear system model. Binning of projection images improves SNR of large objects on the Catphan phantom by decreasing noise. Specific imaging tasks will dictate the implementation image binning to two-dimensional projection images. The project was partially supported by a grant from Varian Medical Systems, Inc. and grant No. R01CA188446-01 from the National Cancer Institute.

60 APPLIED LIFE SCIENCES↗

Evaluation of Low-cost, Full HD, CMOS Cameras for Use in the Calcine Retrieval Project - 19530

This paper describes results from radiation testing conducted on low-cost, commercial off-the-shelf, full high-definition (HD) resolution (1920 x 1080 p), complementary metal-oxide-semiconductor (CMOS) camera sensors. The purpose of the testing was to evaluate the sensors' suitability for use in the Calcine Retrieval Project by determining their image quality and life expectancy while operating in an ionizing radiation field of 20.0 Gy/h. The two camera sensors tested were the Axis FA1105 and Axis FA1125. These commercial camera sensors were designed for retail security surveillance and have no radiation-hardened (rad-hard) components. In addition to radiation testing, the sensors' field-of-view, resolution, and low-light image quality were tested at several target distances to ensure they meet project requirements. Testing was divided into two phases. During Phase 1, four FA1105 sensors and four FA1125 sensors were tested simultaneously without any shielding in radiation fields of 25.5 Gy/h and 49.3 Gy/h. In Phase 2, three FA1105 and five FA1125 sensors were shielded by 22.2 mm of lead and tested simultaneously in radiation fields of 26.8 Gy/h, 52.3 Gy/h, 143.0 Gy/h, 200.7 Gy/h, 404.6 Gy/h, and 2,317.5 Gy/h. Dose rate values were established using film dosimetry readings. Apertures in the shielding allowed for a 40-degree field of view while shielding all parts of the sensor except for directly in front of the CMOS sensor array. All testing was conducted at the Idaho Accelerator Center in Pocatello, Idaho, using a 450 keV X-ray generator. Sensor images were automatically captured at regular intervals throughout the testing for qualitative evaluation by the test team. Film dosimetry was placed near the sensors to record actual dose totals. The 450 keV setting generates X-ray radiation with an energy level close to the primary gamma energy level produced by the Cesium-137 isotope in the calcine, which is 662 keV. Results from Phase 1 indicate the sensors failed at an average cumulative dose of 226.3 Gy. For a given 20.0 Gy/h field this results in a mean time to failure (MTTF) of 11.3 hours. Recorded images from all sensors showed minimal image degradation due to radiation-induced noise. When the sensors finally failed, the failure mode was an abrupt loss of video. The image went black suggesting some other component in the sensor head besides the CMOS sensor array was responsible for the failure. During a portion of Phase 1 testing, a commercial, rad-hard camera was irradiated in the 25.5 Gy/h field along with the eight Axis FA series sensors. Image quality from the FA series sensors significantly outperformed the image quality of the rad-hard camera in radiation-induced noise tolerance, image resolution, and dynamic range. During Phase 2 testing, all sensors produced excellent images in radiation fields as high as 404.6 Gy/h. One FA1125 sensor was tested at the highest dose rate of 2,317.5 Gy/h. At this dose rate, the image was color shifted towards red and contained a significant amount radiation-induced noise. The sensor did not fail and was producing usable imagery after one hour, at which time the test was ended due to allotted beam-time at the test facility. Eighteen hours after X-rays were shut off, the sensor image returned to normal color and all eight sensors continued to operate without any visible, permanent image degradation. For Phase 2 testing, it was not possible to establish a MTTF since none of the shielded sensors failed during the allotted test time. However, given the highest cumulative dose of 4,142.1 Gy received by a shielded FA1125 sensor, a minimum life expectancy of 207 hours (8.6 days) is predicted while operating in a 20.0 Gy/h field. Test results indicate the radiation tolerance of the FA series sensor's CMOS array, along with the small form factor, full HD image quality, wide dynamic range, and Ethernet standard makes it suitable for short-term use in monitoring and visually documenting waste remediation efforts for the Calcine Retrieval Project at the INL. The sensor's low-cost of about $140 US, compared to commercial rad-hard cameras costing between $5,000 and $7,000 US each, allow them to be used as an affordable, disposable resource for many short-duration, radioactive waste remediation efforts where decontamination of an expensive, commercial rad-hard camera is undesirable or not possible. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cone-beam artifact evaluation of the factorization method

Purpose: The authors investigate the CB artifact behavior of the factorization approach recently suggested for image reconstruction in circular cone-beam computed tomography. This investigation is carried out in a typical C-arm geometry and involves simulated data and for the first time also phantom and clinical CB data acquired with a commercially available angiographic system. Methods: The CB artifact level is first measured using quantitative figures-of-merit that are computed from the reconstructions of the mathematical FORBILD head phantom and of a modified disk phantom. The authors then show reconstructions from a physical thorax phantom and clinical head data sets for a visual assessment of image quality. The performance of the factorization method is primarily compared to that of short-scan FDK, but the authors also show the results obtained with the full-scan FDK and the virtual PI-line BPF method for the simulation studies, as a benchmark. Results: Quantitatively, the FORBILD head phantom reconstructions of both FDK methods show a spatially averaged bias of up to 1.2% in the axial slices about 9 cm away from the plane of the scan, which is placed 4 cm below the central slice through the phantom. The artifact level for the short-scan FDK method and the virtual PI-line BPF method noticeably depends on the scan orientation. The factorization approach can significantly reduce both, this dependency as well as the reconstruction bias. It also shows visually an improved quality of the clinical images compared to short-scan FDK, particularly close to the spine and in the subcranial regions of the clinical data sets. Conclusions: The factorization approach comes with noticeably lower reconstruction bias than the FDK methods and is least sensitive to the scan orientation among all considered short-scan methods. The data inconsistencies contained in the real data sets, such as scatter, beam hardening, or data truncation, show only little impact on the factorization results. Hence, in both, reconstructions from real and simulated data, the factorization method yields better image quality than short-scan FDK, albeit at the cost of some slight, directed high-frequency artifacts that are mostly visible in axial slices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Philadelphia Health & Air Quality: Assessing Land Surface Temperature, Vegetation Cover, and Compounding Vulnerability Factors to Identify High Priority Areas for Cooling Initiatives in Philadelphia, Pennsylvania

Heat is the leading cause of weather-related deaths in the US, with heat-related hospitalizations increasing by 2-5% between 2001-2010. In Philadelphia alone, 137 heat-related deaths were recorded between 2010-2018, while a total of 18 daily temperature records have been set since 2010. Temperature is relatively higher in cities compared to rural areas, a phenomenon known as the urban heat island effect. This effect exaggerates daytime maximum temperatures and nighttime heat retention in urban areas, which increases heat exposure in urban environments and especially impacts vulnerable populations. Vulnerability to heat-related illnesses is determined by a combination of risk factors, such as demographics, socioeconomic status, and preexisting health conditions. This project supported the Philadelphia Department of Public Health and Office of Sustainability by identifying priority areas for cooling interventions, such as heat danger educational outreach and urban tree planting. The team developed heat vulnerability scores for each census tract within Philadelphia. Remotely sensed land surface temperature, normalized difference vegetation index, normalized difference built-up index, normalized difference water index, and albedo data were calculated from Aqua Moderate Resolution Imaging Spectroradiometer and Landsat 8 Operational Land Imager/Thermal Infrared Sensor instruments. These variables were weighted against socioeconomic variables and preexisting health conditions using a principal component analysis. A total of 74 census tracts clustered were identified as high-risk areas for heat-related illnesses. 15 of these census tracts also had very low tree density (lower 20th percentile) and should be targeted for tree planting initiatives. The findings of this project will help target interventions to mitigate heat-related health issues and improve the overall wellness of Philadelphia residents.

Health & Air Quality↗