Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Kinetics of thermal de-chlorination of PVC under pyrolytic conditions

Highlights: Black-Right-Pointing-Pointer Several tests were performed in DTA/TGA for understanding the thermal behavior of pure PVC. Black-Right-Pointing-Pointer We did a kinetic model for the de-chlorination of PVC molecule. Black-Right-Pointing-Pointer A temperature of 340 Degree-Sign C was defined as the optimum temperature for breaking the bond of chlorine in the PVC molecule. Black-Right-Pointing-Pointer The experimental validation of this temperature, led to a removal rate of 99.9% chlorine. - Abstract: Although PVC-containing wastes are an important potential source of energy they are frequently disposed in landfill. In thermal treatment processes such as pyrolysis and gasification, the presence of poly(vinyl chloride) (PVC), a compound with 56.7% of chlorine, may cause problems concerned with environmental protection, as consequence of the formation of hydrochloric acid, chlorine gas and dioxins, as well as corrosion phenomena of the reactor/equipment materials. Thus, a possible solution may involve a previous removal of the chlorine from PVC containing waste through a pyrolysis process at low temperatures before the material being submitted to a subsequent thermal treatment, for energetic valorization. In this work, a kinetic model for the thermal decomposition of PVC has been developed, in view of its de-chlorination. DTA/TGA testing at different temperatures indicated a first order reaction and an activation energy of 133,800 J/mol. An almost completed de-chlorination reaction was obtained at 340 Degree-Sign C under an inert atmosphere. The resulted material is a C{sub n}H{sub n} type polymer with potential to be used in an energy recovery process. Validation test performed at laboratory scale indicate that the temperature of 340 Degree-Sign C enables the removal of {approx}99.9% of the chlorine present in PVC. The chloride can be fixed in the form of an aqueous solution of HCl or calcium chloride, driving to an alternative full process with environmental benefits and reduction of the costs associated to the PCV - containing materials/wastes management.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Report on RIA Relevant Modified Burst Testing of ATF Cladding Materials

The mechanical performance of accident-tolerant fuel (ATF) cladding candidates in light-water reactors (LWRs) must be similar to or better than that of current conventional nuclear fuel claddings to reduce dose to the public and ensure a that the core coolable geometry is maintained during a postulated reactivity-initiated accident (RIA) in light-water reactors (LWRs). During an RIA event, the rapid thermal expansion of nuclear fuel can deform the cladding once the fuel–cladding gap closes. In some cases, the pellet–cladding mechanical interaction (PCMI) can induce mechanical failure in ATF candidates. Thus, the mechanical response of ATF cladding must be investigated by mimicking the conditions of RIA and potentially performing Transient Reactor Test (TREAT) experiments to establish or verify the safety envelope. The work presented in this report investigated the failure behavior of as-received, hydrided, and chromium-coated (Cr-coated) Zircaloy-4 (Zry-4) cladding tube under strain-driven mechanical conditions, mimicking postulated RIA loading conditions. Mechanical testing was performed at 300°C via modified burst test (MBT) equipment with pulse width control previously developed under the Department of Energy’s (DOE’s) Advanced Fuel Campaign (AFC). The mechanical strains were determined using 2D digital image correlation (DIC) techniques. The base Zry-4 acquired by Cameco Inc. was in stress-relieved annealed (SRA) condition. Because of the observed large deformation of the cladding tubes, the failure strain definition was updated for the MBT, which can also be applied to other tube tests where significant bulging (out-of-plane deformation) is present. The failure strain was determined to be affected by the speed of the test or the RIA event. As the RIA-like event duration decreased from 75 to 15 ms, the failure strain decreased 5, 7 and 1% for as-received, hydrided, and Cr-coated specimens, respectively. Fractography on the Cr-coated specimens indicated the presence of two failure mechanisms: (i) crenulation at the outer surface of the coating due to the tensile tractional forces along with coatings grain microstructure and (ii) formation of critical defect at the coating/cladding interface that initiated coating rupture after severe plastic deformation of the Zry- 4 substrate. Based on the MBT results and fractography observations, performing mechanical property testing at high strain rates—in particular on Cr-coated tubes—and semi-integral TREAT experiments are required future efforts to ensure ATF cladding performance during transients. The testing recommended would also inform the development of long-term generalized cladding technologies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Benefits of colorectal cancer screening using fecal immunochemical testing with varying positivity thresholds by age and sex

Background Fecal immunochemical test (FIT) performance for colorectal cancer screening varies by age and sex, yet most FIT-based screening programs use uniform positivity thresholds. This study assessed the potential benefits of stratifying FIT thresholds based on age and sex. Methods We conducted a meta-analysis of FIT sensitivity and specificity at various positivity thresholds by age and sex. We then used these estimates in 2 microsimulation models of colorectal cancer and projected lifetime clinical outcomes, incremental costs, and quality-adjusted life-years (QALYs) gained from age- and sex-stratified FIT strategies. FIT thresholds ranged from 10 to 50 µg hemoglobin per gram of feces. Results For current uniform FIT screening (20 µg hemoglobin/gram of feces), models projected 85.67 to 122.15 QALYs gained at incremental costs of ‒$982 to $504 per 1000 individuals compared with no screening. At equivalent costs to current uniform screening, only 1 model found stratified FIT approaches cost-effective, yielding a marginal increase of 1.04 and 1.10 QALYs gained/1000 female and male individuals, respectively. At a willingness-to-pay threshold of $100 000/QALYs gained, both models found stratified FIT cutoffs to be the best strategy, with cutoffs being equal to or higher for males and lowest at older ages (70-75 years). Uniform strategies showed comparable effectiveness, falling within 1 quality-adjusted life-day per person of efficient strategies at up to $112 more per person. Results were sensitive to FIT test performance characteristics and 1-time setup costs. Conclusion Stratifying FIT thresholds by age and sex may be cost-effective compared to current screening. The gain in expected health benefits with stratified FIT screening, however, is likely small.

Harlass, Matthias↗

Progress Report on Modified Burst Testing and Alternative Test Methodologies

Performance of accident-tolerant fuel candidates must be assessed during the pellet-cladding mechanical interaction (PCMI) phase of a design-basis reactivity-initiated accident (RIA). Therefore, in this report, we describe Fiscal Year (FY) 2019 research activities on the development of separate-effects testing for ATF cladding candidate iron-chromium-aluminum (FeCrAl) tube specimens under loading conditions comparable to the PCMI. The first section of this report provides modified-burst test (MBT) results of unirradiated FeCrAl tubes at various pressurization-rates and an RIA-relevant temperature (275°C). The failure strain of FeCrAl was observed and calculated using a high-speed digital-image correlation (DIC) technique developed recently under the Department of Energy (DOE)’s Advanced Fuel Campaign (AFC). To overcome the complexities of performing MBT in a hot-cell environment on irradiated samples, a “plane-strain tension” (PST) test was proposed as an alternative methodology for PCMI testing. The relevance of the PST test as an alternative to MBT for irradiated specimens was explicated using the data available in the literature. The design of hot-cell compatible PST fixtures and a specific holder for PST hot-cell specimen machining were developed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Strain Rate Testing of Welded DOP-26 Iridium

The iridium alloy DOP-26 is used to produce Clad Vent Set cups that protect the radioactive fuel in radioisotope thermoelectric generators (RTGs) which provide electric power for spacecraft and rovers. In a previous study, the tensile properties of DOP-26 were measured over a wide range of strain rates and temperatures and reported in ORNL/TM-2007/81. While that study established the properties of the base material, the fabrication of the heat sources requires welding, and the mechanical properties of welded DOP-26 have not been extensively characterized in the past. Therefore, this study was undertaken to determine the mechanical properties of DOP-26 specimens containing a transverse weld in the center of their gage sections. Tensile tests were performed at room temperature, 750, 900, and 1090°C and engineering strain rates of 1×10 -3 and 10 s -1 . Room temperature testing was performed in air, while testing at elevated temperatures was performed in a vacuum better than 1×10 -4 Torr. The welded specimens had a significantly higher yield stress, by up to a factor of ~2, than the non-welded base material. The yield stress did not depend on the strain rate except at 1090°C, where it was slightly higher for the faster strain rate. The ultimate tensile stress, on the other hand, was significantly higher for the faster strain rate at temperatures of 750°C and above. At 750°C and above, the specimens deformed at 1×10 -3 s -1 showed pronounced necking resulting sometimes in perfect chisel-edge fracture. The specimens deformed at 10 s -1 exhibited this fracture behavior only at the highest test temperature, 1090°C. Fracture occurred usually in the fusion zone of the weld and was, in most cases, primarily intergranular.

36 MATERIALS SCIENCE↗

Elucidating potential-induced degradation in bifacial PERC silicon photovoltaic modules

This paper elucidates the behavior and underlying mechanism of potential-induced degradation (PID) on the rear side of p-type monocrystalline silicon bifacial passivated emitter and rear cell (PERC) photovoltaic modules. At 50 degrees C, 30% relative humidity, and -1000 V bias to the solar cells with aluminium foil on the rear glass surface, the rear-side performance of bifacial PERC modules at standard testing conditions degraded dramatically after 40 hours with a 40.4%, 36.2%, and 7.2% loss in maximum power (Pmpp), short-circuit current (Isc), and open-circuit voltage (Voc), respectively. The front-side standard testing condition performance, on the other hand, showed less degradation; Pmpp, Isc, and Voc dropped by 12.0%, 5.2%, and 5.3%, respectively. However, negligible degradation was observed when the solar cells were positively biased. Based on I-V characteristics, electroluminescence, external quantum efficiency measurements, and the effective minority-carrier lifetime simulation, the efficiency loss is shown to be caused by the surface polarization effect; positive charges are attracted to the passivation/antireflection stack on the rear surface and reduce its field effect passivation performance. Extended PID testing to 100 hours showed an increase in device performances (relative to 40 hours) due to the formation of an inversion layer along the rear surface. In addition, replacing ethylene-vinyl acetate copolymer with polyolefin elastomer films significantly slows down the progression of PID, whereas a glass/transparent backsheet design effectively protects the rear side of bifacial PERC modules from PID. Furthermore, PID on the rear side of bifacial PERC modules is fully recoverable, and light greatly promotes recovery of the observed PID.

14 SOLAR ENERGY↗

FRACTIONAL CRYSALLIZATION LABORATORY TESTS WITH SIMULATED TANK WASTE

Results are presented for several simulated waste tests related to development of the fractional crystallization process. Product salt dissolution rates were measured to support pilot plant equipment design. Evaporation tests were performed to evaluate the effects of organics on slurry behavior and to determine optimum antifoam addition levels. A loss-of-power test was performed to support pilot plant accident scenario analysis. Envelope limit tests were done to address variations in feed composition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FAST - A Unique Experiment and Simplified Approach to Accelerated Integral Fuel Testing

Idaho National Laboratory has a long and internationally recognized history of performing irradiation testing of advanced fast reactor fuels in the Experimental Breeder Reactor II (EBR-II) and the Advanced Test Reactor (ATR). Since EBR-II’s decommissioning in the early 1990’s, irradiation testing has been exclusively performed in ATR. The testing of fast reactor fuels in ATR is challenging given its thermal neutron spectrum and coolant temperatures far below those prototypic of fast reactors. Adept researchers have overcome these obstacles through the use of Cadmium shrouds which attenuate all thermalized neutrons and an experiment design that fosters fuel and cladding temperatures prototypic of fast neutron reactors. Although this design has successfully demonstrated temperatures and temperature gradients that closely mimic those seen in fast reactors, irradiation performance is highly sensitive to fabrication tolerances and the time requirements necessary for high fuel burnup, where irradiation performance data of fast fuel is lacking, are significant. This work summarizes two novel experiment designs and their associated physics analyses for testing fast reactor fuels in ATR; an accelerated irradiation experiment and a fast spectrum experiment. The accelerated irradiation experiment does not utilize a Cadmium shroud, has been shown to triple the burnup rate, yet yields temperatures and radial power profiles prototypic of fast reactor fuels. The fast spectrum experiment utilizes a booster fuel element that that hardens the incident neutron spectrum and also yields temperatures and radial power profiles prototypic of fast reactor fuels. These experiment designs efficiently reduce irradiation time requirements, are more economical, and significantly increase ATR throughput. Fast reactor experiments that capitalize on these designs expedite irradiation performance data for fast reactor fuels and provide information invaluable to fuel performance modeling and simulation validation over a wide range of parameters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Postirradiation Examination of the ATF-1 Experiments - 2019 Status

A collaborative effort of the Advanced Fuels Campaign together with industry consortia is focused on the development of enhanced accident tolerant fuels for Light Water Reactors (LWRs). The scoping studies, referred to as ATF-1 irradiations, are being performed in the Advanced Test Reactor of Idaho National Laboratory using drop-in style irradiations. The Post-Irradiation Examinations (PIEs) of ATF-1 began in 2017 and continued in 2019. This report describes the results of examinations on ATF-1 irradiations designed to test the performance of advanced iron-based cladding, including compatibility of FeCrAl with UO2, and ATF-1 irradiation of U3Si5. Two rodlets with commercial iron-based cladding and UO2 pellets have been irradiated to low burnup (i.e., < 20 GWd/tHM). The first rodlet had an Alloy33 cladding, while the other had a Kanthal APMT® cladding. The performed PIEs were focused on the determination of fuel microstructure, evaluation of fuel-cladding interaction and irradiation-induced variations of cladding mechanical properties. For both rodlets, no significant changes in the cladding hardness were measured, and the cladding hoop strain remained limited. Gamma tomography revealed no Cs axial migration as expected for LWR fuel, but significant cesium radial migration, which was induced by thermal migration consequent to high irradiation temperatures. Microstructure analyses revealed formation of secondary phases along the pellet rim of samples from both rodlets. No wastage or extensive chemical interaction between the fuel and the internal wall of the cladding was observed, suggesting that the secondary phases accumulated at the pellet rim might be due to formation of Cs-U-O compounds. However, further advanced PIEs are necessary to finally confirm this hypothesis. Optical microscopy analysis of the rodlet designed by Oak Ridge National Laboratory to evaluate the interaction between UO2 and various FeCrAl alloys revealed no extensive interaction in all the samples irradiated in the rodlet. Localized defects, namely circular pitting and cracks of a few tents of microns, were observed on the FeCrAl disc surfaces in some of the diffusion couples. These defects might be surface fabrication defects rather than irradiation-induced localized corrosion, but chemical analyses are needed to determine whether accumulation of corrosive fission products are causing enhanced interaction. Both non-destructive and destructive PIEs were collected on a rodlet containing U3Si5 fuel. The rodlet had extremely low fission gas release, similar to previously analyzed U3Si2 rodlets. Gamma tomography revealed thermo-migration of fission product ruthenium toward the center of the fuel pellet. The fuel microstructure resembles the as-fabricated microstructure, showing extensive microcracking related to the phase transition at 450°C. Two types of secondary phases were observed, which could either be due to segregation and precipitation of fission products or to UN impurities from fabrication. Finally, the current status of PIE on other ATF-1 irradiations will be discussed. These irradiations include UN-U3Si5 rodlets, UN-U3Si2 rodlets and an additional test with U3Si2 fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fabrication of yeast engineered porous 13X adsorbent layers for CO 2 capture

This study investigates a novel environmentally friendly coating technique using yeast fermentation to obtain super porous Zeolite 13X adsorbent layers through freeze-drying technique for CO 2 capture applications. Several mass ratios of sugar to yeast were used to control the porosity and pore sizes in the adsorbent layer. A unique peeling process was integrated to obtain foamy, hollow structures to have deeper layer accessibility of adsorbent for adsorption applications. These coated adsorbent layers were experimentally characterized as a function of the mass ratio of sugar to yeast and adsorbent solid fraction. Scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and Fourier-transform infrared spectroscopy (FT-IR) are used to analyze the coated layers. Here, the void fraction for coated samples is found to vary between 0.48 and 0.56, making the samples applicable for adsorption applications. Adsorption performance experiments are performed to test the coated samples' performance compared to 13X powder. Due to their simplistic fabrication, cost-effectiveness, rapid pore formation, and high adsorption capacity, these porous 13X layers hold potential for large-scale fabrication and CO 2 capture applications.

Adsorbent coating↗

Characterization of twin boundaries in an Fe–17.5Mn–0.56C twinning induced plasticity steel

A twinning-induced plasticity steel of composition Fe–17.5 wt.% Mn–0.56 wt.% C–1.39 wt.% Al–0.24 wt.% Si was analyzed for the purpose of characterizing the relationship between tensile strain and deformation twinning. Tensile samples achieved a maximum of 0.46 true strain at failure, and a maximum ultimate tensile strength of 1599 MPa. Electron backscatter diffraction (EBSD) analysis showed that the grain orientation rotated heavily to < 111 > parallel to the tensile axis above 0.3 true strain. Sigma 3 misorientations, as identified by EBSD orientation measurements, and using the image quality maps were used to quantify the number of twins present in the scanned areas of the samples. The image quality method yielded a distinct positive correlation between the twin area density and deformation, but the orientation measurements were unreliable in quantifying twin density in these structures. Quantitative analysis of the twin fraction is limited from orientation information because of the poor spatial resolution of EBSD in relation to the twin thickness. The EBSD orientation maps created for a thin foil sample showed some improvement in the resolution of the twins, but not enough to be significant. Measurements of the twins in the transmission electron microscopy micrographs yielded an average thickness of 23 nm, which is near the resolution capabilities of EBSD on this material for the instrumentation used. Electron channeling contrast imaging performed on one bulk tensile specimen of 0.34 true strain, using a method of controlled diffraction, yielded several images of twinning, dislocation structures and strain fields. A twin thickness of 66 nm was measured by the same method used for the transmission electron microscopy measurement. It is apparent that the results obtain by electron channeling contrast imaging were better than those by EBSD but did not capture all information on the twin boundaries such as was observed by transmission electron microscopy. - Highlights: • Performed tensile tests to assess mechanical performance of TWIP alloy • Analyzed tensile specimens using EBSD, TEM, and ECCI • EBSD showed that most twinning occurred at or near the < 111 >//TA orientation. • EBSD, TEM and ECCI were used to measure average twin density. • Compared spatial resolution of EBSD, ECCI and TEM for the instrumentation used.

36 MATERIALS SCIENCE↗

Resistive switching: An investigation of the bipolar–unipolar transition in Co-doped ZnO thin films

Highlights: • A purely bipolar behavior on a Co-doped ZnO thin film has been demonstrated. • We have shown what can happen if a unipolar test is performed in a purely bipolar device. • An explanation for how a sample can show a purely bipolar switching behavior was suggested. • An important open issue about resistive switching effect was put in debate. - Abstract: In order to investigate the resistive switching effect we built devices in a planar structure in which two Al contacts were deposited on the top of the film and separated by a small gap using a shadow mask. Therefore, two samples of 10% Co-doped ZnO thin films were sputtered on glass substrate. High resolution X-ray diffraction (HRXRD) revealed a highly c-axis oriented crystalline structure, without secondary phase. The high resolution scanning electron microscopy (HRSEM) showed a flat surface with good coverage and thickness about 300 nm. A Keithley 2425 semiconductor characterization system was used to perform the resistive switching tests in the bipolar and unipolar modes. Considering only the effect of compliance current (CC), the devices showed a purely bipolar behavior since an increase in CC did not induce a transition to unipolar behavior.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and performance of a TDC ASIC for the upgrade of the ATLAS Monitored Drift Tube detector

We present the prototype of a time-to-digital (TDC) ASIC for the upgrade of the ATLAS Monitored Drift Tube (MDT) detector for high-luminosity LHC operation. This ASIC is based on a previously submitted demonstrator ASIC designed for timing performance evaluation, and includes all features necessary for the various operation modes, as well as the migration to the TSMC 130 nm CMOS technology. Here, we present the TDC design with the emphasis on added features and performance optimization. Tests of the timing performance demonstrate that this ASIC meets the design specifications. The TDC has a bin size of about 780 ps, and a timing bin variations within ±40 ps for all 24 channels with leading and trailing edge digitization, while the power consumption has been limited to 250 mW, corresponding to a consumption of about 5.2 mW per edge measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mercury oxidation in flue gas using gold and palladium catalysts on fabric filters

The feasibility of oxidizing elemental mercury in coal combustion flue gas using catalytic material impregnated onto fabric filters was explored. TiO{sub 2}, Au/TiO{sub 2}, and Pd/Al{sub 2}O{sub 3} were studied based on promising results in previous research. Several fabric coating methods were investigated to determine the best way to load a filter. A spray coat method was found to have the highest initial loading and had the lowest losses after simulated pulse-jet cleaning. The oxidation performance of the catalyst-coated filters was tested using a simulated flue gas in a bench-scale reactor under conditions similar to those found in a baghouse. Au/TiO{sub 2} and Pd/Al{sub 2}O{sub 3} were effective, yielding mercury oxidation ranges of 40-60% and 50-80%, respectively. A 19 kW research combustor equipped with a baghouse was used to fire a range of coals and further test the performance of Pd/Al{sub 2}O{sub 3}. Results obtained warrant further development of this technique as a means of mercury pollution control. 19 refs., 2 figs., 5 tabs.

01 COAL, LIGNITE, AND PEAT↗

Mid-Range Coil Array for Magnetic Resonance Imaging of Small Animals

The vast majority of articles on MRI RF coils over the past two decades have focused on large coils, where sample losses dominate, or on micro-coils, where sample and capacitor losses are negligible. Few have addressed the mid-range coils, seen in the majority of small-animal applications, where all the sources of loss are important, for example, mouse brain and body coils from 125 to 750 MHz. We developed a four-saddle coil array for magnetic resonance imaging of small animals. The saddle coil elements in the array were evenly distributed to cover the rat's head. The coil array was tuned to the resonant frequency of 170 MHz. Due to the close proximity of the coil elements, it was necessary to decouple the coil array using nonmagnetic trimmers and, it was operated in the transceiver mode and quadrature-driven. To test the coil array performance at high field, phantom images were acquired with our saddle coil array and standard pulse sequences on a research-dedicated 4 Tesla scanner. Ex vivo brain images of a rat were also acquired, and proved the feasibility of the scaled version of a saddle coil array and, its compatibility with standard pulse sequences when used in a high field magnetic resonance imager.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Q-band frequency tunable Doppler backscattering (DBS) system for pedestal and scrape-off layer density fluctuation and flow measurements in the DIII-D tokamak

We present the design and laboratory tests for a new Q-band frequency tunable Doppler backscattering (DBS) system suitable for probing poloidal wavenumber kñ = 6–8 cm−1 density fluctuations and their flow velocities in the pedestal and scape-off layer (SOL) of the DIII-D tokamak. This system will provide new measurements in the increasingly important and under-diagnosed far pedestal and SOL plasma regions. These results are important for experimental transport studies and necessary for the validation of transport models, both of which are important to fusion energy research. The use of a single tunable frequency reduces the complexity and potential failure points as compared to a multichannel system. This new system utilizes a 33–50 GHz tunable source and will be integrated into the current V-band DBS in DIII-D using a broadband Q- and V-band multiplexer. A full-scale mockup of the quasi-optical system was used to test and optimize the performance. These tests include beam profile measurements at different distances (and angles) from a paraboloidal focusing and steering mirror. The measurements cover the full frequency range 33–75 GHz of the integrated/combined Q–V band DBS system and target a large radial coverage of the low-field side of the plasma from ρ = 1.1 to ρ = 0.5, where ρ is the normalized flux surface radial coordinate.

Instruments & Instrumentation↗

355-nm, nanosecond laser mirror thin film damage competition

Here, this competition aimed to survey state-of-the-art UV high reflectors. The requirements of the coatings are a minimum reflection of 99.5% at 45 degrees incidence angle for P-polarized light at 355-nm. The choice of coating materials, design, and deposition method were left to the participants. Laser damage testing was performed at a single testing facility using the raster scan method with a 5-ns pulse length laser system operating at 10 Hz in a single longitudinal mode. A double blind test assured sample and submitter anonymity. Finally, in addition to the laser damage resistance results, details of the deposition processes, cleaning method, coating materials and layer count are also shared.

36 MATERIALS SCIENCE↗

SU-F-T-640: Feasibility of Using a Commercially Available Surface Guided Radiotherapy System with An Open-Face SRS Immobilization System

Purpose: To evaluate the inherent accuracy of using a surface guided radiotherapy system (SGRT) in the setup and monitoring of patients receiving stereotactic radiosurgery with an open-face SRS immobilization system. Methods: An anthropomorphic head phantom was set up using the Qfix Encompass SRS Immobilization System on a Varian Edge with OSMS and Varian TrueBeam with AlignRT. The phantom was positioned at 0° gantry and couch. A reference image was acquired using the SGRT system and an ROI was created over the mask opening. The couch and gantry were rotated to different combinations focusing on clinically used SRS gantry/couch combinations and those blocking the SGRT cameras. Perceived surface deviation by the SGRT system from the reference image was recorded. A Winston-Lutz test was performed on couch angles tested and used to exclude couch walkout. The deviation magnitude was calculated using translational values and rotational raw values were recorded. Results: The maximum couch walkouts were: 0.4mm (Edge) and 0.5mm (TB). Solely rotating the gantry resulted in a median couch deviation of 0.2mm and range of 0.1–0.3mm for both linacs. Only rotating the couch (0° gantry) resulted in median deviations of 0.6mm and 0.5mm with ranges of 0.3–1.0mm and 0.3–0.7mm for the Edge and TB, respectively. Combining gantry and couch rotations, the median deviations were 0.7mm and 0.9mm with ranges of 0.3–1.1mm and 0.2–1.9mm for the Edge and TB, respectively. Including all combinations, rotation, roll, and pitch median deviations ranged from 0.1–0.3° with pitch demonstrating consistently higher values and a maximum deviation of 1.0° (both linacs). Conclusion: SGRT is a reliable monitoring tool, though taking into account system fluctuations, 1mm is too restrictive a site tolerance to use with the Qfix Encompass mask. Gantry rotation has little effect on system fluctuation even with camera blockage, whereas couch rotation has a larger effect.

43 PARTICLE ACCELERATORS↗