Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

JENSA: Past, present, and future

Nuclear reaction studies rely on three main physical components: the beam of nuclei provided by the facility, the detector systems used to measure the outgoing particles of interest, and the target. Target fabrication is thus a critical aspect of studying the reactions that power stars and probe the evolution of nuclear structure. The Jet Experiments in Nuclear Structure and Astrophysics (JENSA) gas jet target is the most dense helium jet target for rare isotope beam reaction studies in the world, providing targets of gaseous elements such as helium, nitrogen, and neon. A brief overview of the design and operation of JENSA, including commissioning and recent science experiments, and a discussion the future of JENSA coupled to the dedicated recoil separator SECAR, are presented.

Chipps, Kelly [ORNL] (ORCID:0000000330501298)↗

Anatomy of Protein Electrospray Ionization Mass Spectra by Superconducting Tunnel Junction Mass and Energy Spectrometry

Cryogenic superconducting tunnel junction (STJ) detectors have the advantage of single-particle sensitivity, high quantum efficiency, low noise, and the ability to detect the time and relative impact energy of deposited ions. This makes them attractive for use in mass spectrometry (MS) and as a form of energy spectrometry. STJ cryodetectors have been coupled to time-offlight (TOF) mass spectrometers equipped with a matrix-assisted laser desorption ionization (MALDI) source and to an electrospray ionization (ESI) TOF mass spectrometer. Here, a lab-made linear ion trap (LIT) mass spectrometer system was coupled to an ESI source and a 16-channel Nb-STJ array with improved readout electronics. The goal was to investigate fundamentals of ESI-generated protein ions by further exploiting the advantage of resolving these ions in a third dimension of the relative energy deposited into the STJs. The proteins equine cytochrome c, bovine carbonic anhydrase, bovine serum albumin, and murine immunoglobulin G were studied using this ESI-LIT-STJ-MS instrument. Multiply charged monomers, multimers, and fragments from metastable ions were resolved from monomer peaks by differences in ion deposition energy even when these ions have the same mass-to-charge ratio as the corresponding monomer. The determination of fragment mass from metastable decomposition is accomplished without knowing the charge state of the fragment. The average charge state of the multimers is reduced with each addition of a protein which is a direct reflection of the surface area available for charging. Multiply charged in-source fragments have also been observed and distinguished in the mass spectrum of carbonic anhydrase by using the differences in the energy deposited in the STJs.

42 ENGINEERING↗

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specific integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifiers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verified using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗

Cadmium Magnesium Telluride for Next Generation X-Ray Free Electron Laser, Synchrotron and Many Other Applications

We developed a picosecond photodetector based on our Bridgman grown and specially engineered Cadmium Magnesium Telluride (Cd 1-x Mg x Te) single crystal that is sensitive to both optical and x-ray pulses for coarse timing in Free Electron Laser applications. Cd 1-x Mg x Te is a wide bandgap semiconductor material with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma ray radiation, thermal neutrons, and medical imaging. However, for femtosecond optical and x-ray cross correlation, the material has to have very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have very low bulk leakage current, in the 0.10 pA range. Hence the ability to tailor or engineer the material is very crucial. In this paper, picosecond response and the crystal growth of this specially engineered cadmium magnesium telluride material will be presented. Other material characterization and transient measurements will also be discussed along with room temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

System Response Characterization for a d–t Neutron Radiography System

We report the system response of a pixelated associated particle imaging (API) neutron radiography system. The detector readout currently consists of a 2x2 array of organic glass scintillator detectors, each with an 8x8 array of optically isolated pixels that match the size and pitch of the ARRAYJ-60035-64P-PCB Silicon Photomultiplier (SiPM) array from SensL/onsemi with 6x6 mm 2 SiPMs. The alpha screen of the API deuterium-tritium neutron generator is read out with the S13361-3050AE-08 from Hamamatsu, which is an 8x8 array of 3x3 mm 2 SiPMs. Data from the 320 channel system is acquired with the TOFPET2-based readout system. We present the predicted imaging capability of an eventual 5x5 detector array, the waveform-based energy and pulse shape characterization of the individual detectors, and the timing and energy response from the TOFPET2 system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond Timing

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specifc integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verifed using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗

Low-Energy Backgrounds in Solid-State Phonon and Charge Detectors

Solid-state phonon and charge detectors probe the scattering of weakly interacting particles, such as dark matter and neutrinos, through their low recoil thresholds. Recent advancements have pushed sensitivity to eV-scale energy depositions, uncovering previously-unseen low-energy excess backgrounds. While some arise from known processes such as thermal radiation, luminescence, and stress, others remain unexplained. This review examines these backgrounds, their possible origins, and parallels to low-energy effects in solids. Their understanding is essential for interpreting particle interactions at and below the eV-scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Processings of the Workshop on Electron Contamination in X-Ray Astronomy Experiments

The proceedings of a conference to investigate the effects of extraterrestrial radiation and particle contamination of X-ray astronomical data are presented. The subjects discussed include the following: (1) electrons at low altitudes which affect soft X-ray astronomy, (2) the geographical distribution of 100 keV electrons above the earth's atmosphere, (3) midlatitude electron precipitation, (4) particle background observed by X-ray detectors on board Copernicus satellite, and (5) a survey of trapped low energy electrons near the inner boundary of the inner radiation zone as determined by OSO-7.

Holt, S. S.↗

Apollo 17 mission Report. Supplement 6: Calibration results for gamma ray spectrometer sodium iodide crystal

A major difficulty in medium energy gamma-ray remote sensing spectroscopy and astronomy measurements was the high rate of unwanted background resulting from the following major sources: (1) prompt secondary gamma-rays produced by cosmic-ray interactions in satellite materials; (2) direct charged-particle counts; (3) radioactivity induced in the detector materials by cosmic-ray and trapped protons; (4) radioactivity induced in detector materials by the planetary (e.g., earth or moon) albedo neutron flux; (5) radioactivity induced in the detector materials by the interaction of secondary neutrons produced throughout the spacecraft by cosmic-ray and trapped proton interactions; (6) radioactivity induced in spacecraft materials by the mechanisms outlined in 3, 4, and 5; and (7) natural radioactivity in spacecraft and detector materials. The purpose of this experiment was to obtain information on effects 3, 4, and 5, and from this information start developing calculational methods for predicting the background induced in the crystal detector in order to correct the Apollo gamma-ray spectrometer data for this interference.

Dyer, C.↗

Angular distributions of solar protons and electrons

High angular-resolution measurements of directional fluxes of solar particles in space have been obtained with detectors aboard OGO-5 during the cosmic ray event of Nov. 18, 1968. This is the only case on record for which sharply-defined directional observations of protons and electrons covering a wide rigidity range (0.3 MV to 1.5 GV) are available. The satellite experiment provided data for determining pitch-angle distributions with respect to the direction of the local interplanetary magnetic field lines during the lengthy highly anisotropic phase of the event. The results have been interpreted in the light of the temporal flux profiles and the state of the interplanetary medium.

Nielsen, E.↗

Observation of the plasma boundary layer at lunar distances - Direct injection of plasma into the plasma sheet

The paper presents observational evidence from the Apollo suprathermal ion detector experiments that the injection of magnetosheath particles at the low-latitude magnetopause operates at lunar distances as well. An interface between the magnetosheath and the plasma sheet, termed the plasma sheet boundary layer (PSBL), is identified and believed to be the extension of the magnetospheric boundary layer (also called the plasma boundary layer) observed on the dayside. Using measurements of the PSBL's thickness, magnetic field, and plasma velocity the average electric potential drop across the PSBL is estimated at 4.2 kV and compared with the potential drop which is needed to insure that the magnetopause is an equipotential for a closed magnetosphere. It was concluded though that the magnetosphere is open since this drop is much larger than 4.2 kV.

Sanders, G. D.↗

The ISPM dust experiment

The ISPM Dust Experiment observes particulate matter with masses between 10 to the minus 19th power and 10 to the minus 10th power kg in the solar system; investigates its physical and dynamical properties as a function of ecliptic latitude and heliocentric distance; and studies its interaction with solar radiation, the solar wind, and the interplanetary magnetic field. Measurement of the three dimensional spatial distribution of cosmic dust particles and their dynamics allows the relative significance of their probable sources (comets, asteroids and interstellar dust) to be determined. An instrument that measures the mass, speed, flight direction and electric charge of individual dust particles is used. It is a multicoincidence detector with a sensitivity 100,000 times higher than that of previous experiments. The instrument weighs 3.750 kg, consumes 2.0 W, and has a normal data transmission rate of 8 bit/sec in spacecraft tracking mode.

Gruen, E.↗

The Nagoya cosmic-ray muon spectrometer 3, part 4: Track reconstruction method

One of the greatest problems in measuring particle trajectories with an optical or visual detector system, is the reconstruction of trajectories in real space from their recorded images. In the Nagoya cosmic-ray muon spectrometer, muon tracks are detected by wide gap spark chambers and their images are recorded on the photographic film through an optical system of 10 mirrors and two cameras. For the spatial reconstruction, 42 parameters of the optical system should be known to determine the configuration of this system. It is almost impossible to measure this many parameters directly with usual techniques. In order to solve this problem, the inverse transformation method was applied. In this method, all the optical parameters are determined from the locations of fiducial marks in real space and the locations of their images on the photographic film by the non-linear least square fitting.

Shibata, S.↗

Search for long-lived massive particles in extensive air showers

Air showers containing delayed sub-showers which may be produced by a long-lived massive particle have been investigated by using twelve detectors. Ten events have been selected out as the candidates. However, a definite conclusion cannot be reached at the present time.

Kawamoto, M.↗

Calibration of the thin film filters to be used on the Extreme Ultraviolet Explorer Satellite

The methods of calibrating the filters used on the Extreme Ultraviolet Explorer (EUVE) astronomical satellite are described. EUVE will conduct the first all-sky survey in the entire EUV band. The measurement of the filters' transmission properties from the soft X-ray to the far UV using a grazing incidence monochromator is discussed. A particle ingress test to determine the ability of the filters to inhibit energetic particles in earth orbit from entering the detector and increasing the background is described. Problems encountered in calibrating these four filters are also presented.

Vallerga, John↗

A study of the scintillation light induced in liquid xenon by electrons and alpha particles

The time dependence and the intensity of the primary scintillation light in liquid Xe excited by Am-241 alpha particles and Bi-207 internal-conversion electrons were measured at different electric-field strengths. High-purity liquid Xe was used to fill a parallel-plate ionization chamber equipped with a CaF2 window coupled to a UV-sensitive photomultiplier tube. The effect of the specific ionization density on the scintillation light and the time correlation between the light signal and the charge signal is reported. It is demonstrated that the fast scintillation signal produced in liquid Xe by an ionizing particle provides an ideal trigger in a detector aiming at a complete three-dimensional event reconstruction with an excellent background rejection capability.

Aprile, Elena↗

Science requirements for Heavy Nuclei Collection (HNC) experiment on NASA Long Duration Exposure Facility (LDEF) Mission 2

The Heavy Nuclei Collection (HNC) is a passive array of stacks of a special glass, 14 sheets thick, that record tracks of ultraheavy cosmic rays for later readout by automated systems on Earth. The primary goal is to determine the relative abundances of both the odd- and even-Z cosmic rays with Z equal to or greater than 50 with statistics a factor at least 60 greater than obtained in HEAO-3 and to obtain charge resolution at least as good as 0.25 charge unit. The secondary goal is to search for hypothetical particles such as superheavy elements. The HNC detector array will have a cumulative collection power equivalent to flying 32 sq m of detectors in space for 4 years. The array will be flown as a free-flight spacecraft and/or attached to Space Station Freedom.

Price, P. Buford↗

Calculations of multiple scattering-induced errors in the GLAS mission

The Geoscience Lidar Altimeter System (GLAS) is a laser altimeter designed to measure temporal changes in the topography and mass balance of the Earth's ice sheets. GLAS is scheduled to be launched as part of the Earth Observing System (EOS) in 2001. Due to the large pulse width of GLAS and the slope (and roughness) of the ice sheets, the mean elevation of the laser's surface spot will be estimated from the centroid of the return pulse. While the accuracy of individual altimetry measurements is expected to be 15 cm, a cross-over technique that averages the elevation differences at selected points on the ice sheets will allow GLAS to detect mean ice elevation changes as small as 2 cm per year. One factor that may degrade the proposed accuracy of the altimeter measurements is the effect of multiple scattering by thin clouds and aerosols over the ice sheets. In the return pulse, some photons from the lidar are slightly deflected by cloud particles but still return to the instrument detector. Since these photons travel a longer path than photons that pass directly to and from the surface, the mean travel time of the pulse is lengthened and the centroid of the return pulse is shifted toward a later time . This study intends to determine the importance of this source of altimetry error in the GLAS measurements. Two methods will be used to estimate path delays in the GLAS lidar for a range of cloud conditions. An analytic expression of a doubly scattered return signal (Eloranta, 1972) will be compared to Monte Carlo simulations that estimate path delays by cloud, aerosol and molecular scattering. The results from both methods will be discussed in relationship to current knowledge of Arctic cloud climatology, and the impact of multiple scattering on GLAS altimeter measurements will be evaluated.

Duda, David P.↗