Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POSITRON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Implications of the first AMS-02 measurement for dark matter annihilation and decay

In light of the first measurement of the positron fraction by the AMS-02 experiment, we perform a detailed global analysis on the interpretation of the latest data of PAMELA, Fermi-LAT, and AMS-02 in terms of dark matter (DM) annihilation and decay in various propagation models. The allowed regions for the DM particle mass and annihilation cross section or decay life-time are obtained for channels with leptonic final states: 2e, 2μ, 2τ, 4e, 4μ and 4τ. We show that for the conventional astrophysical background the AMS-02 positron fraction data alone favour a DM particle mass ∼ 500(800) GeV if DM particles annihilate dominantly into 2μ(4μ) final states, which is significantly lower than that favoured by the Fermi-LAT data of the total flux of electrons and positrons. The allowed regions by the two experiments do not overlap at a high confidence level (99.99999%C.L.). We consider a number of propagation models with different halo height Z{sub h}, diffusion parameters D{sub 0} and δ{sub 1/2}, and power indices of primary nucleon sources γ{sub p1/p2}. The normalization and the slope of the electron background are also allowed to vary. We find that the tension between the two experiments can be only slightly reduced in the propagation model with large Z{sub h} and D{sub 0}. The consistency of fit is improved for annihilation channels with 2τ and 4τ final states which favour TeV scale DM particle with large cross sections above ∼ 10{sup −23} cm{sup 3}s{sup −1}. In all the considered leptonic channels, the current data favour the scenario of DM annihilation over DM decay. In the decay scenario, the charge asymmetric DM decay is slightly favoured.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutrino-induced {gamma}-ray emission from supernovae

During a core-collapse supernova, absorption of {nu}{sub e} emitted from the protoneutron star by protons in the hydrogen envelope produces neutrons and positrons. Neutron capture on protons and positron annihilation then produce {gamma} rays of 2.22 and 0.511 MeV, respectively. We calculate the fluxes of these {gamma} rays expected from a supernova with an 11M{sub {center_dot}} progenitor. The flux from neutron capture on protons exponentially decays on a time scale of 564 s, which is determined by neutron decay and capture on protons and {sup 3}He nuclei. The peak flux is 2.38x10{sup -7} cm{sup -2} s{sup -1} for a supernova at a distance of 1 kpc. In contrast, the {gamma}-ray flux from positron annihilation follows the time evolution of the {nu}{sub e} luminosity and lasts for {approx}10 s. The peak flux in this case is 6.8x10{sup -5} cm{sup -2} s{sup -1} for a supernova at a distance of 1 kpc. Detection of the above {gamma}-ray fluxes is beyond the capability of current instruments, and perhaps even those planned for the near future. However, if such fluxes can be detected, they not only constitute a new kind of signal that occurs during the gap of several hours between the neutrino signals and the optical display of a supernova, but may also provide a useful probe of the conditions in the surface layers of the supernova progenitor.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Antimatter cosmic rays from dark matter annihilation: First results from an N-body experiment

While the particle hypothesis for dark matter may be very soon investigated at the LHC, and as the PAMELA and GLAST satellites are currently taking new data on charged and gamma cosmic rays, the need of controlling the theoretical uncertainties affecting the possible indirect signatures of dark matter annihilation is of paramount importance. The uncertainties which originate from the dark matter distribution are difficult to estimate because current astrophysical observations provide rather weak dynamical constraints and because, according to cosmological N-body simulations, dark matter is neither smoothly nor spherically distributed in galactic halos. Some previous studies made use of N-body simulations to compute the {gamma}-ray flux from dark matter annihilation, but such a work has never been performed for the antimatter (positron and antiproton) primary fluxes, for which transport processes complicate the calculations. We take advantage of the galaxylike 3D dark matter map extracted from the Horizon Project results to calculate the positron and antiproton fluxes from dark matter annihilation, in a model-independent approach as well as for dark matter particle benchmarks relevant at the LHC scale (from supersymmetric and extradimensional theories). We find that the flux uncertainties arise mainly from fluctuations of the local dark matter density, and are of {approx}1 order of magnitude. We compare our results to analytic descriptions of the dark matter halo, showing how the latter can well reproduce the former. The overall antimatter predictions associated with our benchmark models are shown to lie far below the existing measurements and, in particular, that of the positron fraction recently reported by PAMELA, and far below the background predictions as well. Finally, we stress the limits of the use of an N-body framework in this context.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermalization of the mildly relativistic plasma

In a recent paper [A. G. Aksenov, R. Ruffini, and G. V. Vereshchagin, Phys. Rev. Lett. 99, 125003 (2007).] we considered the approach of nonequilibrium pair plasma towards a thermal equilibrium state adopting a kinetic treatment and solving numerically the relativistic Boltzmann equations. It was shown that plasma in the energy range 0.1-10 MeV reaches kinetic equilibrium first, on a time scale t{sub k} < or approx. 10{sup -14} sec, with detailed balance between binary interactions such as Compton, Bhabha, and Moeller scattering, and pair production and annihilation. Later the electron-positron-photon plasma approaches thermal equilibrium on a time scale t{sub th} < or approx. 10{sup -12} sec, with detailed balance for all direct and inverse reactions. In the present paper we systematically present details of the computational scheme used there, as well as generalize our treatment, considering proton loading of the pair plasma. When proton loading is large, protons thermalize first by proton-proton scattering, and then, with the electron-positron-photon plasma, by proton-electron scattering. In the opposite case of small proton loading, proton-electron scattering dominates over proton-proton scattering. Thus in all cases the plasma, even with a proton admixture, reaches a thermal equilibrium configuration on a time scale t{sub th} < or approx. 10{sup -11} sec. We show that it is crucial to account for not only binary but also triple direct and inverse interactions between electrons, positrons, photons, and protons. Several explicit examples are given, and the corresponding time scales for reaching kinetic and thermal equilibria are determined.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark matter annihilation rates with velocity-dependent annihilation cross sections

The detection of by-products from particle annihilations in galactic halos would provide important information about the nature of the dark matter. Observational evidence for a local excess of high-energy positrons has motivated recent models with an additional interaction between dark matter particles that can result in a Sommerfeld enhancement to the cross section. In such models, the cross section for annihilation becomes velocity-dependent and may enhance the dark matter annihilation rate in the solar neighborhood relative to the rate in the early Universe sufficiently to source observed fluxes of high-energy positrons. We demonstrate that, for particle interaction cross sections that increase with decreasing velocity, the kinematical structures of dark matter halos with interior density profiles shallower than isothermal, such as Navarro-Frenk-White or Einasto halos, may induce a further enhancement owing to the position-dependent velocity distribution. We provide specific examples for the increase in the annihilation rate with a cross section enhanced by the Sommerfeld effect. In dark matter halos like that of the Milky Way and Local Group dwarf galaxies, the effective cross section at the halo center can be significantly larger than its local value. The additional enhancement owing to halo kinematics depends upon the parameters of any model, but is a prediction of certain models aimed at explaining measured positron fluxes and can exceed an order of magnitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pulsars versus dark matter interpretation of ATIC/PAMELA

In this paper, we study the flux of electrons and positrons injected by pulsars and by annihilating or decaying dark matter in the context of recent ATIC, PAMELA, Fermi, and HESS data. We review the flux from a single pulsar and derive the flux from a distribution of pulsars. We point out that the particle acceleration in the pulsar magnetosphere is insufficient to explain the observed excess of electrons and positrons with energy E{approx}1 TeV and one has to take into account an additional acceleration of electrons at the termination shock between the pulsar and its wind nebula. We show that at energies less than a few hundred GeV, the expected flux from a continuous distribution of pulsars provides a good approximation to the expected flux from pulsars in the Australia Telescope National Facility catalog. At higher energies, we demonstrate that the electron/positron flux measured at the Earth will be dominated by a few young nearby pulsars, and therefore the spectrum would contain bumplike features. We argue that the presence of such features at high energies would strongly suggest a pulsar origin of the anomalous contribution to electron and positron fluxes. The absence of features either points to a dark matter origin or constrains pulsar models in such a way that the fluctuations are suppressed. Also we derive that the features can be partially smeared due to spatial variation of the energy losses during propagation.

79 ASTRONOMY AND ASTROPHYSICS↗

Exciting dark matter in the Galactic Center

We reconsider the proposal of excited dark matter (DM) as an explanation for excess 511 keV gamma rays from positrons in the Galactic center. We quantitatively compute the cross section for DM annihilation to nearby excited states, mediated by exchange of a new light gauge boson with off-diagonal couplings to the DM states. In models where both excited states must be heavy enough to decay into e{sup +}e{sup -} and the ground state, the predicted rate of positron production is never large enough to agree with observations, unless one makes extreme assumptions about the local circular velocity in the Milky Way, or alternatively if there exists a metastable population of DM states which can be excited through a mass gap of less than 650 keV, before decaying into electrons and positrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Metastable dark matter mechanisms for INTEGRAL 511 keV {gamma} rays and DAMA/CoGeNT events

We explore dark matter mechanisms that can simultaneously explain the galactic 511 keV gamma rays observed by INTEGRAL/SPI, the DAMA/LIBRA annual modulation, and the excess of low-recoil dark matter candidates observed by CoGeNT. It requires three nearly degenerate states of dark matter in the 4-7 GeV mass range, with splittings, respectively, of order MeV and a few keV. The top two states have the small mass gap and transitions between them, either exothermic or endothermic, and can account for direct detections. Decays from one of the top states to the ground state produce low-energy positrons in the Galaxy whose associated 511 keV gamma rays are seen by INTEGRAL. This decay can happen spontaneously, if the excited state is metastable (longer lived than the age of the Universe), or it can be triggered by inelastic scattering of the metastable states into the shorter-lived ones. We focus on a simple model where the dark matter is a triplet of an SU(2) hidden sector gauge symmetry, broken at the scale of a few GeV, giving masses of order < or approx. 1 GeV to the dark gauge bosons, which mix kinetically with the standard model hypercharge. The purely decaying scenario can give the observed angular dependence of the 511 keV signal with no positron diffusion, while the inelastic scattering mechanism requires transport of the positrons over distances {approx}1 kpc before annihilating. We note that an x-ray line of several keV in energy, due to single-photon decays involving the top dark matter states, could provide an additional component to the diffuse x-ray background. The model is testable by proposed low-energy fixed-target experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Measurement of the Angular Coefficients of Drell-Yan e{sup +}e{sup -} Pairs in the Z Mass Region from pp Collisions at {radical}(s)=1.96 TeV

We report on the first measurement of the angular distributions of final state electrons in pp{yields}{gamma}{sup *}/Z{yields}e{sup +}e{sup -}+X events produced in the Z boson mass region at {radical}(s)=1.96 TeV. The data sample collected by the CDF II detector for this result corresponds to 2.1 fb{sup -1} of integrated luminosity. The angular distributions are studied as a function of the transverse momentum of the electron-positron pair and show good agreement with the Lam-Tung relation, consistent with a spin-1 description of the gluon, and demonstrate that, at high values of the transverse momentum, Z bosons are produced via quark-antiquark annihilation and quark-gluon Compton processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of PhytoPET: A plant imaging PET system

The development and initial evaluation of a high-resolution positron emission tomography (PET) system to image the biodistribution of positron emitting tracers in live plants is underway. The positron emitting {sup 11}CO{sub 2} tracer is used in plant biology research investigating carbon sequestration in biomass, optimization of plant productivity and biofuel development. This PhytoPET design allows flexible arrangements of PET detectors based on individual standalone detector modules built from single 5 cm x 5 cm Hamamatsu H8500 position sensitive photomultiplier tubes. Each H8500 is coupled to a LYSO:Ce scintillator array composed of 48 x 48 elements that are 10 mm thick arranged with a 1.0 mm pitch. An Ethernet based 12-bit flash analog to digital data acquisition system with onboard coincident matrix definition is under development to digitize the signals. The detector modules of the PhytoPET system can be arranged and stacked to accommodate various sized plants and plant structures.

09 BIOMASS FUELS↗

SU-F-T-368: Improved HPGe Detector Precise Efficiency Calibration with Monte Carlo Simulations and Radioactive Sources

Purpose: To obtain an improved precise gamma efficiency calibration curve of HPGe (High Purity Germanium) detector with a new comprehensive approach. Methods: Both of radioactive sources and Monte Carlo simulation (CYLTRAN) are used to determine HPGe gamma efficiency for energy range of 0–8 MeV. The HPGe is a GMX coaxial 280 cm{sup 3} N-type 70% gamma detector. Using Momentum Achromat Recoil Spectrometer (MARS) at the K500 superconducting cyclotron of Texas A&M University, the radioactive nucleus {sup 24} Al was produced and separated. This nucleus has positron decays followed by gamma transitions up to 8 MeV from {sup 24} Mg excited states which is used to do HPGe efficiency calibration. Results: With {sup 24} Al gamma energy spectrum up to 8MeV, the efficiency for γ ray 7.07 MeV at 4.9 cm distance away from the radioactive source {sup 24} Al was obtained at a value of 0.194(4)%, by carefully considering various factors such as positron annihilation, peak summing effect, beta detector efficiency and internal conversion effect. The Monte Carlo simulation (CYLTRAN) gave a value of 0.189%, which was in agreement with the experimental measurements. Applying to different energy points, then a precise efficiency calibration curve of HPGe detector up to 7.07 MeV at 4.9 cm distance away from the source {sup 24} Al was obtained. Using the same data analysis procedure, the efficiency for the 7.07 MeV gamma ray at 15.1 cm from the source {sup 24} Al was obtained at a value of 0.0387(6)%. MC simulation got a similar value of 0.0395%. This discrepancy led us to assign an uncertainty of 3% to the efficiency at 15.1 cm up to 7.07 MeV. The MC calculations also reproduced the intensity of observed single-and double-escape peaks, providing that the effects of positron annihilation-in-flight were incorporated. Conclusion: The precision improved gamma efficiency calibration curve provides more accurate radiation detection and dose calculation for cancer radiotherapy treatment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new mechanism for void-cascade interaction from nondestructive depth-resolved atomic-scale measurements of ion irradiation–induced defects in Fe

The nondestructive investigation of single vacancies and vacancy clusters in ion-irradiated samples requires a depth-resolved probe with atomic sensitivity to defects. The recent development of short-pulsed positron beams provides such a probe. Here, we combine depth-resolved Doppler broadening and positron annihilation lifetime spectroscopies to identify vacancy clusters in ion-irradiated Fe and measure their density as a function of depth. Despite large concentrations of dislocations and voids in the pristine samples, positron annihilation measurements uncovered the structure of vacancy clusters and the change in their size and density with irradiation dose. When combined with transmission electron microscopy measurements, the study demonstrates an association between the increase in the density of small vacancy clusters with irradiation and a remarkable reduction in the size of large voids. This, previously unknown, mechanism for the interaction of cascade damage with voids in ion-irradiated materials is a consequence of the high porosity of the initial microstructure.

36 MATERIALS SCIENCE↗

Absorption of gamma-ray photons in a vacuum neutron star magnetosphere: II. The formation of 'lightnings'

The absorption of a high-energy photon from the external cosmic gamma-ray background in the inner neutron star magnetosphere triggers the generation of a secondary electron-positron plasma and gives rise to a lightning-a lengthening and simultaneously expanding plasma tube. It propagates along magnetic fields lines with a velocity close to the speed of light. The high electron-positron plasma generation rate leads to dynamical screening of the longitudinal electric field that is provided not by charge separation but by electric current growth in the lightning. The lightning radius is comparable to the polar cap radius of a radio pulsar. The number of electron-positron pairs produced in the lightning in its lifetime reaches 10{sup 28}. The density of the forming plasma is comparable to or even higher than that in the polar cap regions of ordinary pulsars. This suggests that the radio emission from individual lightnings can be observed. Since the formation time of the radio emission is limited by the lightning lifetime, the possible single short radio bursts may be associated with rotating radio transients (RRATs).

79 ASTRONOMY AND ASTROPHYSICS↗

Ion-acoustic Gardner solitons in a four-component nonextensive multi-ion plasma

The nonlinear propagation of ion-acoustic (IA) solitary waves (SWs) in a four-component non-extensive multi-ion plasma system containing inertial positively charged light ions, negatively charged heavy ions, as well as noninertial nonextensive electrons and positrons has been theoretically investigated. The reductive perturbation method has been employed to derive the nonlinear equations, namely, Korteweg−deVries (KdV), modified KdV (mKdV), and Gardner equations. The basic features (viz. polarity, amplitude, width, etc.) of Gardner solitons are found to exist beyond the KdV limit and these IA Gardner solitons are qualitatively different from the KdV and mKdV solitons. It is observed that the basic features of IA SWs are modified by various plasma parameters (viz. electron and positron nonextensivity, electron number density to ion number density, and electron temperature to positron temperature, etc.) of the considered plasma system. The results obtained from this theoretical investigation may be useful in understanding the basic features of IA SWs propagating in both space and laboratory plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear propagation of ion-acoustic waves through the Burgers equation in weakly relativistic plasmas

The Burgers equation is obtained to study the characteristics of nonlinear propagation of ionacoustic shock, singular kink, and periodic waves in weakly relativistic plasmas containing relativistic thermal ions, nonextensive distributed electrons, Boltzmann distributed positrons, and kinematic viscosity of ions using the well-known reductive perturbation technique. This equation is solved by employing the (G'/G)-expansion method taking unperturbed positron-to-electron concentration ratio, electron-to-positron temperature ratio, strength of electrons nonextensivity, ion kinematic viscosity, and weakly relativistic streaming factor. The influences of plasma parameters on nonlinear propagation of ion-acoustic shock, periodic, and singular kink waves are displayed graphically and the relevant physical explanations are described. It is found that these parameters extensively modify the shock structures excitation. The obtained results may be useful in understanding the features of small but finite amplitude localized relativistic ion-acoustic shock waves in an unmagnetized plasma system for some astrophysical compact objects and space plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion-Scale Excitations in a Strongly Coupled Astrophysical Plasma with Nuclei of Heavy Elements

The linear and nonlinear propagation of ultrarelativistic and nonrelativistic analysis on modified ion-acoustic (MIA) waves in a strongly coupled unmagnetized collisionless relativistic space plasma system is carried out. Plasma system is assumed to contain strongly coupled nonrelativistic ion fluids, both nonrelativistic and ultrarelativistic degenerate electron and positron fluids, and positively charged static heavy elements. The restoring force is provided by the degenerate pressure of the electron and positron fluids, whereas the inertia is provided by the mass of ions. The positively charged static heavy elements participate only in maintaining the quasineutrality condition at equilibrium. The well-known reductive perturbation method is used to derive the Burgers and Korteweg–de Vries equations. Their shock and solitary wave solutions are numerically analyzed to understand the localized electrostatic disturbances. The basic characteristics of MIA shock and solitary waves are found to be significantly modified by the effects of degenerate pressures of electron, positron, and ion fluids, their number densities, and various charge state of heavy elements. The implications of our results to dense plasmas in compact astrophysical objects (e.g., nonrotating white dwarfs, neutron stars, etc.) are briefly discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preparation of Radiopharmaceuticals Labeled with Metal Radionuclides

The overall goal of this project was to develop methods for the production of metal-based radionuclides, to develop metal-based radiopharmaceuticals and in a limited number of cases, to translate these agents to the clinical situation. Initial work concentrated on the application of the radionuclides of Cu, Cu-60, Cu-61 and Cu-64, as well as application of Ga-68 radiopharmaceuticals. Initially Cu-64 was produced at the Missouri University Research Reactor and experiments carried out at Washington University. A limited number of studies were carried out utilizing Cu-62, a generator produced radionuclide produced by Mallinckrodt Inc. (now Covidien). In these studies, copper-62-labeled pyruvaldehyde Bis(N{sup 4}-methylthiosemicarbazonato)-copper(II) was studied as an agent for cerebral myocardial perfusion. A remote system for the production of this radiopharmaceutical was developed and a limited number of patient studies carried out with this agent. Various other copper radiopharmaceuticals were investigated, these included copper labeled blood imaging agents as well as Cu-64 labeled antibodies. Cu-64 labeled antibodies targeting colon cancer were translated to the human situation. Cu-64 was also used to label peptides (Cu-64 octriatide) and this is one of the first applications of a peptide radiolabeled with a positron emitting metal radionuclide. Investigations were then pursued on the preparation of the copper radionuclides on a small biomedical cyclotron. A system for the production of high specific activity Cu-64 was developed and initially the Cu-64 was utilized to study the hypoxic imaging agent Cu-64 ATSM. Utilizing the same target system, other positron emitting metal radionuclides were produced, these were Y-86 and Ga-66. Radiopharmaceuticals were labeled utilizing both of these radionuclides. Many studies were carried out in animal models on the uptake of Cu-ATSM in hypoxic tissue. The hypothesis is that Cu-ATSM retention in vivo is dependent upon the oxygen retention of the tissue and the significantly greater retention amounting in hypoxic tissue. This hypothesis was confirmed in a series of animal studies. Cu-64 can be used both as an imaging radionuclide and a therapeutic radionuclide. The therapeutic efficacy of Cu-64 ATSM was proven in hamsters bearing the CW39 human colorectal tumors. The administration of Cu-64 ATSM significantly increased the survival time of tumor-bearing animals with no acute toxicity. This copper agent therefore shows promise for radiotherapy. The flow tracer Cu-64 PTSM also demonstrates therapeutic potential by inhibiting cancer cells implanted in animal models. Again, this inhibition occurred at doses which showed no sign of toxicity to the animals. Cu-ATSM was translated to humans, under other support a series of tumors were investigated; these included head and neck cancer, non-small cell lung cancer, cervical cancer and renal cancer. Another radionuclide that was investigated was titanium 45. This radionuclide was successfully produced by radiation of a scandium foil with 15 MeV protons. The titanium 45 was processed and separated from residual scandium by high exchange chomotrophy. Titanium titanocene has been utilized as a therapeutic agent; this compound was prepared and studied in vitro and in vivo. Another project was the preparation of cyclodextrin dimers as a new pre-targeting approach for tumor uptake. Beta-cyclodextradin and two other dimers were synthesized. These dimers were studied for the in vivo application. Work continued on the application of the radionuclide already discussed. Technetium 94m, a positron emitting radionuclide of the widely used 99m Tc nuclide was also prepared. This allows the quantification of the uptake of technetium radiopharmaceuticals. In collaboration with Professor David Piwnica-Worms, technetium 94m, sestamibi was studied in animal models and in a limited number of human subjects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final Technical Report: "New Tools for Physics with Low-energy Antimatter"

The objective of this research is to develop new tools to manipulate antimatter plasmas and to tailor them for specific scientific and technical uses. The work has two specific objectives. One is establishing the limits for positron accumulation and confinement in the form of single-component plasmas in Penning-Malmberg traps. This technique underpins a wealth of antimatter applications. A second objective is to develop an understanding of the limits for formation of cold, bright positron beams. The research done in this grant focused on particular facets of these goals. One focus was extracting tailored beams from a high-field Penning-Malmberg trap from the magnetic field to form new kinds of high-quality electrostatic beams. A second goal was to develop the technology for colder trap-based beams using a cryogenically cooled buffer gas. A third objective was to conduct the basic plasma research to develop a new high-capacity multicell trap (MCT) for research with antimatter. Progress is reported here in all three areas. While the goal of this research is to develop new tools for manipulating positrons (i.e., the antiparticles of electrons), much of the work was done with test electron plasmas for increased data rate. Some of the techniques developed in the course of this work are also relevant to the manipulation and use of antiprotons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗