Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PORT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Analysing the 100year sea level record of Leixões, Portugal

A new data set from the tide gauge at Leixões (North–West Portugal) has recently been transferred from its paper format into a digital time series of hourly sea level values. By measuring sea level variations since 1890, this tide gauge station is one of the few in the world with over 100 yr of digitised hourly records and the longest for the South West of Europe and Iberian Peninsula. This paper presents the procedures adopted to recover the Leixões sea level data from paper chart records as well as the data quality control and data editing methodologies. The mean rate of sea level change between 1906 and 2008 is -0.70 ± 0.27 mm yr -1 , which does not agree with the global mean sea level rise of 1-2 mm yr -1 . No evidence for vertical land movement was found and Global Isostatic Adjustment influence on sea level, at this location, can be neglected. It is likely that prevailing weather systems in the North Atlantic, especially in the winter, and local atmospheric pressure, influence sea levels at Leixões. A further contribution is found from tides and surges. The evolution of the port cannot be ignored when trying to understand sea level change.

Engineering↗

Crystal Structure of Fatty Acid Amide Hydrolase Bound to the Carbamate Inhibitor URB597: Discovery of a Deacylating Water Molecule and Insight into Enzyme Inactivation

The endocannabinoid system regulates a wide range of physiological processes including pain, inflammation, and cognitive/emotional states. URB597 is one of the best characterized covalent inhibitors of the endocannabinoid-degrading enzyme fatty acid amide hydrolase (FAAH). Here, we report the structure of the FAAH-URB597 complex at 2.3 {angstrom} resolution. The structure provides insights into mechanistic details of enzyme inactivation and experimental evidence of a previously uncharacterized active site water molecule that likely is involved in substrate deacylation. This water molecule is part of an extensive hydrogen-bonding network and is coordinated indirectly to residues lining the cytosolic port of the enzyme. In order to corroborate our hypothesis concerning the role of this water molecule in FAAH's catalytic mechanism, we determined the structure of FAAH conjugated to a urea-based inhibitor, PF-3845, to a higher resolution (2.4 {angstrom}) than previously reported. The higher-resolution structure confirms the presence of the water molecule in a virtually identical location in the active site. Examination of the structures of serine hydrolases that are non-homologous to FAAH, such as elastase, trypsin, or chymotrypsin, shows a similarly positioned hydrolytic water molecule and suggests a functional convergence between the amidase signature enzymes and serine proteases.

36 MATERIALS SCIENCE↗

Exploring performance and energy tradeoffs for irregular applications: A case study on the Tilera many-core architecture

High performance, parallel applications with irregular data accesses are becoming a critical workload class for modern systems. In particular, the execution of such workloads on emerging many-core systems is expected to be a significant component of applications in data mining, machine learning, scientific computing and graph analytics. However, power and energy constraints limit the capabilities of individual cores, memory hierarchy and on-chip interconnect of such systems, thus leading to architectural and software trade-os that must be understood in the context of the intended application’s behavior. Irregular applications are notoriously hard to optimize given their data-dependent access patterns, lack of structured locality and complex data structures and code patterns. We have ported two irregular applications, graph community detection using the Louvain method (Grappolo) and high-performance conjugate gradient (HPCCG), to the Tilera many-core system and have conducted a detailed study of platform-independent and platform-specific optimizations that improve their performance as well as reduce their overall energy consumption. To conduct this study, we employ an auto-tuning based approach that explores the optimization design space along three dimensions - memory layout schemes, GCC compiler flag choices and OpenMP loop scheduling options. We leverage MIT’s OpenTuner auto-tuning framework to explore and recommend energy optimal choices for different combinations of parameters. We then conduct an in-depth architectural characterization to understand the memory behavior of the selected workloads. Finally, we perform a correlation study to demonstrate the interplay between the hardware behavior and application characteristics. Using auto-tuning, we demonstrate whole-node energy savings and performance improvements of up to 49:6% and 60% relative to a baseline instantiation, and up to 31% and 45:4% relative to manually optimized variants.

auto tuning↗

Microstructure and mechanical properties development of micro channel tubes in extrusion, rolling and brazing

Highlights: • Rolling and brazing greatly affect the properties of micro-channel tubes (MCTs). • The properties of MCTs are investigated by the evolution of the microstructure. • Strength is decreased by 47% at 5%-rolling reduction ratio and 3-minute brazing. • Ductile fracture mode is observed by OM at failure of MCTs under inner pressure. - Abstract: In addition to extrusion, the post-processing of rolling and brazing has significant effect on the mechanical properties of multi-port tubes. The aluminum micro channel tubes, especially the seam welding zone in the internal webs, are investigated in terms of mechanical tests, microstructure characterization, and finite element analysis. The effect of the post-process of rolling are quantified by varying amount of rolling reduction ratios. Tensile strength and pressure bearing capacity are determined by tensile tests and burst pressure tests, respectively. The evolution of the microstructure within the seam wielding zone is characterized by Electron backscattered diffraction (EBSD) and optical microscopy (OM). The fracture profile observed by OM indicates ductile fracture mode. The pressure bearing capacity is reduced by ~47% at 5% reduction ratio of rolling followed by 3-minute brazing, where largest grains are obtained due to abnormal grain growth.

36 MATERIALS SCIENCE↗

Co-design of a wave energy converter through bi-conjugate impedance matching

As with other oscillatory power conversion systems, the design of wave energy converters can be understood as an impedance matching problem. By representing the wave energy converter as a multi-port network, two separate but related impedance matching conditions can be established. Satisfying these conditions maximizes power transfer to the load. In practice, these impedance matching conditions may be used to influence the design of the system (including the hull, power take-off, controller, mooring, etc.). To this end, this paper considers some example applications of wave energy converter design with the help of the impedance matching framework.

WEC↗

Fully implicit crystal plasticity models representing orientations with modified Rodrigues parameters

Here, this work describes a crystal plasticity formulation combining several mathematical, numerical, and implementation choices to produce a highly efficient model. Specifically, the key choices in the implementation are (1) representing orientations with modified Rodrigues parameters, (2) implementing a fully coupled implicit time integration for the elastic stretch, the crystal orientations, and the model internal variables, (3) implementing the model in the NEML2 constitutive modeling framework, based on PyTorch, to vectorize the calculations and port the computation to GPUs and other hardware accelerators, and (4) an exact implementation of the consistent tangent matrix, even for arbitrary coupling to other field variables beyond the displacements, like temperature, neutron fluence, etc. The first two features of the model are, to our knowledge, novel. The paper considers each of these choices individually as well as the final model as a whole. This includes a full description of modified Rodrigues parameters, their advantages over other representations of orientations, the mathematical formulae and tools required to implement a model with modified Rodrigues parameters, and a detailed description of the geometry of the space of modified Rodrigues parameters (in an appendix). It also includes a description of a fully implicit time integration scheme for the orientations and the advantages in representing orientations with modified Rodrigues parameters in implementing such a model. The work then assess, via numerical examples, the advantages of fully coupled implicit time integration versus more common decoupled and explicit time integration schemes. These studies demonstrate the computational advantages of fully coupled integration versus other time integration algorithms, though the performance of the competing models depends on the complexity of the underlying single crystal model. The study concludes by demonstrating that the choice of time integration method affects the sharpness of the predicted texture, with explicit methods for integrating the orientations overestimating texture sharpness and implicit methods underestimating texture sharpness.

Crystal plasticity↗

A Simple Technique of Supine Craniospinal Irradiation

We describe a simple procedure of craniospinal irradiation in supine position. The procedure was carried out with a 100-cm isocenter linear accelerator and compatible simulator. Treatment was with a 1 or 2 posteroanterior (PA)-directed spinal fields abutting lateral-directed cranial fields. Abutment of the fields was established by placement of markers on the neck of the patient, which provided a measure of the divergence of the spinal field. The precision and reproducibility of this technique, including the placement of junctions, appeared to be as good as for treatment in the prone position. The same could be verified with port films. We conclude that this new technique of supine craniospinal treatment is a simple and convenient alternative to traditional treatment in the prone position.

61 RADIATION PROTECTION AND DOSIMETRY↗

Upright 3D Treatment Planning Using a Vertical CT

In this report, we describe a novel technique used to plan and administer external beam radiation therapy to a patient in the upright position. A patient required reirradiation for thymic carcinoma but was unable to tolerate the supine position due to bilateral phrenic nerve injury and paralysis of the diaphragm. Computed tomography (CT) images in the upright position were acquired at the Northern Illinois University Institute for Neutron Therapy at Fermilab. The CT data were imported into a standard 3-dimensional (3D) treatment planning system. Treatment was designed to deliver 24 Gy to the target volume while respecting normal tissue tolerances. A custom chair that locked into the treatment table indexing system was constructed for immobilization, and port films verified the reproducibility of setup. Radiation was administered using mixed photon and electron AP fields.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postoperative Intensity Modulated Radiation Therapy in High Risk Prostate Cancer: A Dosimetric Comparison

The aim of this study was to compare intensity-modulated radiation therapy (IMRT) with 3D conformal technique (3D-CRT), with respect to target coverage and irradiation of organs at risk for high dose postoperative radiotherapy (PORT) of the prostate fossa. 3D-CRT and IMRT treatment plans were compared with respect to dose to the rectum and bladder. The dosimetric comparison was carried out in 15 patients considering 2 different scenarios: (1) exclusive prostate fossa irradiation, and (2) pelvic node irradiation followed by a boost on the prostate fossa. In scenario (1), a 3D-CRT plan (box technique) and an IMRT plan were calculated and compared for each patient. In scenario (2), 3 treatment plans were calculated and compared for each patient: (a) 3D-CRT box technique for both pelvic (prophylactic nodal irradiation) and prostate fossa irradiation (3D-CRT only); (b) 3D-CRT box technique for pelvic irradiation followed by an IMRT boost to the prostatic fossa (hybrid 3D-CRT and IMRT); and (c) IMRT for both pelvic and prostate fossa irradiation (IMRT only). For exclusive prostate fossa irradiation, IMRT significantly reduced the dose to the rectum (lower Dmean, V50%, V75%, V90%, V100%, EUD, and NTCP) and the bladder (lower Dmean, V50%, V90%, EUD and NTCP). When prophylactic irradiation of the pelvis was also considered, plan C (IMRT only) performed better than plan B (hybrid 3D-CRT and IMRT) as respect to both rectum and bladder irradiation (reduction of Dmean, V50%, V75%, V90%, equivalent uniform dose [EUD], and normal tissue complication probability [NTCP]). Plan (b) (hybrid 3D-CRT and IMRT) performed better than plan (a) (3D-CRT only) with respect to dose to the rectum (lower Dmean, V75%, V90%, V100%, EUD, and NTCP) and the bladder (Dmean, EUD, and NTCP). Postoperative IMRT in prostate cancer significantly reduces rectum and bladder irradiation compared with 3D-CRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Simple shielding reduces dose to the contralateral breast during prone breast cancer radiotherapy

Our goal was to design a prone breast shield for the contralateral breast and study its efficacy in decreasing scatter radiation to the contralateral breast in a prone breast phantom setup receiving radiation therapy designed for breast cancer. We constructed a prone breast phantom setup consisting of (1) A thermoplastic mask with a left-sided depression created by a water balloon for a breast shape; (2) 2 plastic bags to hold water in the thermoplastic mask depression; (3) 2000 mL of water to fill the thermoplastic mask depression to create a water-based false breast; (4) 1-cm thick bolus placed in the contralateral breast holder; (5) 2 lead (Pb) sheets, each 0.1-cm thick for blocking scatter radiation in the contralateral bolus-based false breast; (6) a prone breast board to hold the thermoplastic mask, water, bolus, and lead; (7) 9 cm solid water on top of the breast board to simulate body; (8) a diode was used to verify dose for each treatment field of the treated water-based breast; (9) metal–oxide–semiconductor-field effect transistor (MOSFET) dosimeters to measure dose to the contralateral bolus-based breast. The phantom prone breast setup was CT simulated and treatment was designed with 95% isodose line covering the treated breast. The maximum dose was 107.1%. Megavoltage (MV) port images ensured accurate setup. Measurements were done using diodes on the treated water-based breast and MOSFET dosimeters at the medial and lateral sides of the contralateral bolus-based breast without and with the Pb shield. Five treatments were done for each of the 3 data sets and recorded individually for statistical purposes. All treatments were completed with 6 MV photons at 200 cGy per treatment. The dose contributions from each of the 3 data sets including 15 treatments total without and with the prone lead shield to the medial and lateral portions of contralateral bolus-based breast were averaged individually. Unshielded dose means were 37.11 and 2.94 cGy, and shielded dose means were 12.68 and 1.54 cGy, respectively. When comparing medial and lateral portions of the contralateral bolus-based doses without and with Pb, the shield significantly reduced dose to both sides of the contralateral breast (medial p = 2.64 × 10{sup −14}, lateral p = 4.91 × 10{sup −6}). The prone 0.2-cm Pb shield significantly reduced scatter dose to the contralateral breast on the order of 2 to 3 times. Reductions may be clinically relevant for women younger than 45 years by decreasing the risk of contralateral radiation-induced breast cancer in patients receiving radiation therapy for breast cancer. This shield is simple as it would be a part of the prone breast board during treatments, but future studies are warranted for safety and efficacy clinically.

61 RADIATION PROTECTION AND DOSIMETRY↗

Stable electrospray signal on a microfabricated glass chip with three-dimensional open edge and tiered depth geometries

This paper presents the microfabrication and performance of a three-dimensional electrospray ionization (ESI) emitter tip made from glass, which achieves stable current signals important for chemical analysis. Our novel microfabrication process and custom-built signal conditioning hardware provides the advantage of providing accurate features and steady signals. The fabrication process relies on standard microfabrication techniques (i.e., deposition, photolithography, and wet etching). This fabrication method involves the novel application of two layers of positive and negative photoresists in addition to Parafilm® wax tape. Open edge and tiered depth details were successfully created from a multilayer planar mask. This is a benefit for integrated miniaturized and microfluidic systems that often require micro features for their functionality but relatively large millimeter size features for their physical periphery. We demonstrate the fundamental performance of electrospray with this microfluidic chip. The emitter tip was fixed on a linear axis stage with high resolution (10 μm) to finely control the tip distance from a metal counter electrode plate. Further, a custom printed circuit board system was built to safely control four voltages applied to the microchip ports from a single high voltage power supply. To readily form the electrospray, non-aqueous solvents were used for their low viscosity and a constant voltage of +2.7 kV was applied to the sheath electrospray microchannel. The liquid being sprayed was 80/20 (v/v) methanol/acetonitrile with 0.1% acetic acid in the sheath microchannel and with ammonium acetate (10–40 mM) in its remaining microchannels. The electrospray signal was measured in response to varying the distance (1.4 to 1.6mm) between the electrospray emitter tip and a metal counter electrode plate in addition to the varying concentration of the background electrolyte, ammonium acetate. Stable and repeatable electrospray signal showed linear relationships with emitter tip distance and concentration (r 2 ≥ 0.95).

42 ENGINEERING↗

Summary of the Workshop on Neutron Cross Section Covariances

A Workshop on Neutron Cross Section Covariances was held from June 24-27, 2008, in Port Jefferson, New York. This Workshop was organized by the National Nuclear Data Center, Brookhaven National Laboratory, to provide a forum for reporting on the status of the growing field of neutron cross section covariances for applications and for discussing future directions of the work in this field. The Workshop focused on the following four major topical areas: covariance methodology, recent covariance evaluations, covariance applications, and user perspectives. Attention was given to the entire spectrum of neutron cross section covariance concerns ranging from light nuclei to the actinides, and from the thermal energy region to 20 MeV. The papers presented at this conference explored topics ranging from fundamental nuclear physics concerns to very specific applications in advanced reactor design and nuclear criticality safety. This paper provides a summary of this workshop. Brief comments on the highlights of each Workshop contribution are provided. In addition, a perspective on the achievements and shortcomings of the Workshop as well as on the future direction of research in this field is offered.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preface by the CW2014 Organizers-Including Program, Advisory Board, Participants and Photo

This issue of the Nuclear Data Sheets contains the proceedings of the 'International Workshop on Nuclear Data Covariances'. This workshop was the third one in a series that started with the 'Workshop on Neutron Cross Section Covariances' (Port Je erson, USA, 2008) and continued with the 'Second Workshop on Neutron Cross Section Covariances' (Vienna, Austria, 2011). The current workshop returned to the US and took place in the center of the beautiful and historic city of Santa Fe, New Mexico, USA from April 28 to May 1, 2014. The purpose of this workshop was to bring together scientists in the field of nuclear data evaluation, nuclear reaction theory, reactor physics and associated experiments to review recent developments in nuclear data evaluation methodology as well as assess and discuss open questions regarding uncertainty estimates and associated formatting requirements from the point of view of the experimentalist, the theoretician, the evaluator as well as from application side, e.g. in transport calculations. The workshop was open to contributions on a wide variety of nuclear data observables (cross sections, fission yields, energy and angle spectra, etc.), from the resonance range up to the high energy range as well as for light to heavy elements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gamma Ray Mirrors for Direct Measurement of Spent Nuclear Fuel

Direct measurement of the amount of Pu and U in spent nuclear fuel represents a challenge for the safeguards community. Ideally, the characteristic gamma-ray emission lines from different isotopes provide an observable suitable for this task. However, these lines are generally lost in the fierce flux of radiation emitted by the fuel. The rates are so high that detector dead times limit measurements to only very small solid angles of the fuel. Only through the use of carefully designed view ports and long dwell times are such measurements possible. Recent advances in multilayer grazing-incidence gamma-ray optics provide one possible means of overcoming this difficulty. With a proper optical and coating design, such optics can serve as a notch filter, passing only narrow regions of the overall spectrum to a fully shielded detector that does not view the spent fuel directly. We report on the design of a mirror system and a number of experimental measurements.

multilayer mirrors↗

Limits of special material detectability fundamental to idealized dual-energy radiographic systems

Analysis of dual-energy radiographic approaches to the detection of “special” material, i.e. contraband, in otherwise innocuous scenes, such as maritime cargo containers encountered at ports of entry, reveals fundamental limitations of data obtained along a single line-of-sight. The basic equations that describe idealized systems are presented and analyzed so as to identify challenges that are only exacerbated by scatter, noise, and measurement uncertainty. In the mono-energetic limit, the instrumentation and measurement methods reduce to a system of linear equations that are simple to treat: it is observed that there exists a threshold for the minimum amount of high-Z material that can be detected unambiguously (without the risk of false positive or false negative indications), even when the background materials are of finite and of well-known variety. The threshold depends on the quality of prior information about the cargo and the selection of probing energies, and can therefore be minimized by good system design practices and measurement procedures, but persists as a general challenge to security operations. In discussion of this result, it is noted that techniques incorporating other prior information, such as the geometry of cargo and potential contraband, along with data from 2D imaging, have far greater potential. For instance, a simple data analysis method capable of differentiating high-Z spheres from those of more common material is presented. This simple example demonstrates that, although simple line-of-sight transmission radiography may suffer fundamental limitations, there remains good cause to be optimistic about the potential for image analysis in radiographic material identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam impedance and heating analysis of the diagnostic stripline

In this work the heat transfer analysis has been performed for the stripline kicker, design of which is used at many accelerator facilities as a part of the transverse bunch-by-bunch feed-back system, including NSLS-II. The experimental data of the electrode temperature have been collected from a special diagnostic stripline designed with six infrared view ports. The temperature analysis is based on the power loss calculations and the loss factor computed by the 3-D electromagnetic simulation code GdfidL. To estimate the power loss, we analyze the real part of the longitudinal impedance and the loss factor for two different regimes. We use the ANSYS finite element code to correlate the temperature with the power loss. Lambertson and Shafer formalisms of the longitudinal and transverse beam impedances are discussed for the simplified stripline geometries. The required characteristic impedances and the geometric factors are determined analytically for the simplified geometries and compared with the results for the designed stripline geometry using the 2-D POISSON code by solving the Laplace’s equation in two dimensions. Lambertson’s equations are compared with numerical results. We introduce the frequency range, within which we can apply the analytical approach.

43 PARTICLE ACCELERATORS↗

Effect of natural gamma background radiation on portal monitor radioisotope unmixing

It is well known that national security relies on several layers of protection. One of the most important is the traffic control at borders and ports that exploits Radiation Portal Monitors (RPMs) to detect and deter potential smuggling attempts. Most portal monitors rely on plastic scintillators to detect gamma rays. Despite their poor energy resolution, their cost effectiveness and the possibility of growing them in large sizes make them the gamma-ray detector of choice in RPMs. Unmixing algorithms applied to organic scintillator spectra can be used to reliably identify the bare and unshielded radionuclides that triggered an alarm, even with fewer than 1000 detected counts and in the presence of two or three nuclides at the same time. In this work, we experimentally studied the robustness of a state-of-the-art unmixing algorithm to different radiation background spectra, due to varying atmospheric conditions, in the 16 °C to 28 °C temperature range. In the presence of background, the algorithm is able to identify the nuclides present in unknown radionuclide mixtures of three nuclides, when at least 1000 counts from the sources are detected. With fewer counts available, we found larger differences of approximately 35.9% between estimated nuclide fractions and actual ones. In these low count rate regimes, the uncertainty associated by our algorithm with the identified fractions could be an additional valuable tool to determine whether the identification is reliable or a longer measurement to increase the signal-to-noise ratio is needed. Moreover, the algorithm identification performances are consistent throughout different data sets, with negligible differences in the presence of background types of different intensity and spectral shape.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗