Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optics and Optical Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Compact Instrument for Measuring Profile of a Light Beam

The beamviewer is an optical device designed to be attached to a charge-coupled-device (CCD) image detector for measuring the spatial distribution of intensity of a beam of light (the beam profile ) at a designated plane intersecting the beam. The beamviewer-and-CCD combination is particularly well suited for measuring the radiant- power profile (for a steady beam) or the radiant-energy profile (for a pulsed beam) impinging on the input face or emerging from the output face of a bundle of optical fibers. The beamviewer and-CCD combination could also be used as a general laboratory instrument for profiling light beams, including beams emerging through small holes and laser beams in free space.

Papanyan, Valeri↗

Initial materials evaluation of the thermal control surfaces experiment (S0069)

The Thermal Control Surface Experiment (TCSE) was flown on the NASA Long Duration Exposure Facility (LDEF) with the basic objective of determining the effects of the near-earth orbital environment and the LDEF induced environment on spacecraft thermal control surfaces. The TCSE was a comprehensive experiment that combined in-space measurements with extensive post-flight analyses of thermal control surfaces to determine the effects of exposure to the low earth orbit space environment. The TCSE is the first space experiment to measure the optical properties of thermal control surfaces the way they are routinely measured in the laboratory. The specific mission objectives of the TCSE were to: (1) determine the effects of the natural and induced space environment on thermal control surfaces; (2) provide in-space performance data on thermal control surfaces; (3) provide in-space comparison to ground-based environmental testing of materials; and (4) develop and prove instrumentation to perform in-space optical testing of materials. Various aspects of the experiment are discussed.

Donald R. Wilkes↗

The NIRCam Optical Telescope Simulator (NOTES)

The Near Infra-Red Camera (NIRCam), the 0.6-5.0 micron imager and wavefront sensing instrument for the James Webb Space Telescope (JWST), will be used on orbit both as a science instrument, and to tune the alignment of the telescope. The NIRCam Optical Telescope Element Simulator (NOTES) will be used during ground testing to provide an external stimulus to verify wavefront error, imaging characteristics, and wavefront sensing performance of this crucial instrument. NOTES is being designed and built by NASA Goddard Space Flight Center with the help of Swales Aerospace and Orbital Sciences Corporation. It is a single-point imaging system that uses an elliptical mirror to form an U20 image of a point source. The point source will be fed via optical fibers from outside the vacuum chamber. A tip/tilt mirror is used to change the chief ray angle of the beam as it passes through the aperture stop and thus steer the image over NIRCam's field of view without moving the pupil or introducing field aberrations. Interchangeable aperture stop elements allow us to simulate perfect JWST wavefronts for wavefront error testing, or introduce transmissive phase plates to simulate a misaligned JWST segmented mirror for wavefront sensing verification. NOTES will be maintained at an operating temperature of 80K during testing using thermal switches, allowing it to operate within the same test chamber as the NIRCam instrument. We discuss NOTES' current design status and on-going development activities.

Kubalak, David↗

Focus determination for the James Webb Space Telescope Science Instruments: A Survey of Methods

The James Webb Space Telescope (JWST) is a segmented deployable telescope that will require on-orbit alignment using the Near Infrared Camera as a wavefront sensor. The telescope will be aligned by adjusting seven degrees of freedom on each of 18 primary mirror segments and five degrees of freedom on the secondary mirror to optimize the performance of the telescope and camera at a wavelength of 2 microns. With the completion of these adjustments, the telescope focus is set and the optical performance of each of the other science instruments should then be optimal without making further telescope focus adjustments for each individual instrument. This alignment approach requires confocality of the instruments after integration and alignment to the composite metering structure, which will be verified during instrument level testing at Goddard Space Flight Center with a telescope optical simulator. In this paper, we present the results from a study of several analytical approaches to determine the focus for each instrument. The goal of the study is to compare the accuracies obtained for each method, and to select the most feasible for use during optical testing.

Davila, Pamela S.↗

Range Imaging without Moving Parts

Range-imaging instruments of a type now under development are intended to generate the equivalent of three-dimensional images from measurements of the round-trip times of flight of laser pulses along known directions. These instruments could also provide information on characteristics of targets, including roughnesses and reflectivities of surfaces and optical densities of such semi-solid objects as trees and clouds. Unlike in prior range-imaging instruments based on times of flight along known directions, there would be no moving parts; aiming of the laser beams along the known directions would not be accomplished by mechanical scanning of mirrors, prisms, or other optical components. Instead, aiming would be accomplished by using solid-state devices to switch input and output beams along different fiber-optic paths. Because of the lack of moving parts, these instruments could be extraordinarily reliable, rugged, and long-lasting. An instrument of this type would include an optical transmitter that would send out a laser pulse along a chosen direction to a target. An optical receiver coaligned with the transmitter would measure the temporally varying intensity of laser light reflected from the target to determine the distance and surface characteristics of the target. The transmitter would be a combination of devices for generating precise directional laser illumination. It would include a pulsed laser, the output of which would be coupled into a fiber-optic cable with a fan-out and solid-state optical switches that would enable switching of the laser beam onto one or more optical fibers terminated at known locations in an array on a face at the focal plane of a telescope. The array would be imaged by the telescope onto the target space. The receiver optical system could share the aforementioned telescope with the transmitter or could include a separate telescope aimed in the same direction as that of the transmitting telescope. In either case, light reflected from the target would be focused by the receiver optical system onto an array of optical fibers matching the array in the transmitter. These optical fibers would couple the received light to one or more photodetector( s). Optionally, the receiver could include solid-state optical switches for choosing which optical fiber(s) would couple light to the photodetector(s). This instrument architecture is flexible and can be optimized for a wide variety of applications and levels of performance. For example, it is scalable to any number of pixels and pixel resolutions and is compatible with a variety of ranging and photodetection methodologies, including, for example, ranging by use of modulated (including pulsed and encoded) light signals. The use of fixed arrays of optical fibers to generate controlled illumination patterns would eliminate the mechanical complexity and much of the bulk of optomechanical scanning assemblies. Furthermore, digital control of the selection of the fiber-optic pathways for the transmitted beams could afford capabilities not seen in previous three-dimensional range-imaging systems. Instruments of this type could be specialized for use as, for example, proximity detectors, three-dimensional robotic vision systems, airborne terrain-mapping systems, and inspection systems.

Blair, J. Bryan↗

Impact of COVID-Global Shutdown on Earth's Radiation Budget

Climate is fueled by how much of the sun’s energy is absorbed by Earth. Changes in aerosol emissions have a direct impact how much solar energy is absorbed under clear-sky conditions, which occurs roughly one-third of the time globally. Aerosol emission changes can also indirectly influence clouds and further alter solar energy absorption. In this presentation, we examine the impact of the COVID-19 global shutdown on Earth’s radiation budget at global and regional scales and compare it with other changes that have had an influence on Earth's radiation budget during the past 20 years—including policy-related emission controls, wildfire events and changes in sea-ice extent in polar regions. We use a novel analysis technique together with data from NASA instruments on the Terra, Aqua and Aura satellites and reanalysis data from MERRA-2. We also compare results with state-of-the-art general circulation models that have been nudged to reanalysis data (winds, air temperature and surface 25 pressure) at all levels. Our preliminary results show that the largest COVID-19 impact occurs regionally over the East Asian Marginal Seas, just off the coast of China. We find a 30% reduction in aerosol optical depth according to the MODIS instrument, and an 8% reduction in reflected solar radiation according to the CERES radiation budget instrument. The climate model simulations show remarkable consistency with the observations and furthermore show no evidence of an indirect effect on cloud properties.

Norman G. Loeb↗

Curved Diffractive X-ray Optics for X-ray Astronomy

We report on a concept for curved diffractive X-ray optics (CDXO). CDXO would enable potential new optical designs for X-ray instruments, such as a two element spectrometer, in which the secondary element of an X-ray mirror pair is patterned with an X-ray grating. A two-element spectrometer design eliminates the grating assembly, resulting in decreased instrument mass and reduced power requirements. In addition, a two-element spectrometer may realize cost/schedule savings by eliminating a separate grating alignment effort, and yield increased effective area over three element designs. We present a raytrace concept study of a two-element spectrometer compact enough to fit within a sounding rocket payload. We also review the progress made in electron-beam lithography (EBL) techniques that would enable curved diffractive X-ray optics to be patterned, and outline a procedure by which the accuracy of the EBL patterning process can be measured interferometrically.

Casey T. DeRoo↗

Optical Strain Measurement System Development

Investigations of physical phenomena affecting the durability of SSME components require measurement systems operational in hostile environments. The need for such instrumentation caused the definition and operation of an optical strain measurement system. This optical strain measurement system based on the speckle shift method is being developed. This is a noncontact, automatic method of measuring surface strain in one dimension that corrects for error due to rigid body motion. It provides a gauge length of 1 to 2 mm and allows the region of interest on the test specimen to be mapped point by point. The output is a graphics map of the points inspected on the specimen; data points is stored in quasi-real time. This is the first phase of a multiphase effort in optical strain measurement. The speckle pattern created by the test specimen is interpreted as high order interference fringes resulting from a random diffraction grating, being the natural surface roughness of the specimen. Strain induced on the specimen causes a change in spacing of the surface roughness, which in turn shifts the position of the interference pattern (speckles).

Lant, C. T.↗

Lightning Optical Pulse Statistics from Storm Overflights During the Altus Cumulus Electrification Study

The Altus Cumulus Electrification Study (ACES) was conducted during the month of August, 2002 in an area near Key West, Florida. One of the goals of this uninhabited aerial vehicle (UAV) study was to collect time resolved optical pulse data from thunderstorms. During the month long campaign, we acquired 5294 lightning generated optical pulses. Most of these observations were made while close to the top of the storms. We divided our data into two amplitude groups based on prior NASA U2 aircraft optical data and our pulse characteristics. The group of large pulses with radiance greater than 2.1 mW /sq m sr had mean and median 10 - 10% optical pulse widths of 765 and 735 microns respectively, the 50-50% pulse widths of 396 and 355 microns respectively, and 10-90% rise times of 290 and 260 microns. These values are very similar to the previous U2 based optical results The other group of pulses consisting of slightly more than a quarter of the total pulses observed had radiances less than the minimum values detected in the U2 study. The small pulses were narrower than the large pulses with 5040% mean and median values of 198 and 160 ps respectively. Only 12 % of the flashes contained only small pulses, minimizing the impact of this data on the estimates of detection efficiencies of the orbital instruments, the Lightning Imaging Sensor and Optical Transient Detector.

Mach, D. M.↗

Preliminary cryogenic performance of the Shuttle Infrared Telescope Facility

The Shuttle Infrared Telescope Facility (SIRTF) is a cryogenically cooled telescope in the one-meter aperture class designed for sensing in the infrared from 2-200 microns. This facility is designed to be flown many times on the Space Shuttle with varying instrument complements. All components of the SIRTF within the field of view of the optics are cryogenically cooled. The primary coolant is supercritical helium which is stored in an external tank and routed through the telescope - cooling the instruments first, then the optical components and finally the baffles. For detector cooling below 6K small reservoirs of superfluid helium (He II) are provided. The SIRTF cryogenic system is designed to automatically control the tank pressure and telescope flow rates during prelaunch operations and flight as well as meet the Space Shuttle environmental and safety requirements. Temperatures maintained in the telescope are a function of instrument operation, design, energy dissipation, and telescope pointing angle. By control of the cryogen flow rate any selected instrument temperature can be maintained within fixed limits, and the critical secondary mirror can be maintained below 10K throughout a 14-day mission. Instrument thermal design is a critical factor in the maintenance of proper temperature differences in the experiment package. Design of a cryogenic telescope for space use presents many problems which do not exist in earth based systems. The limited opportunity for servicing, the restricted coolant supply, and the remote instrumentation and control all provide new considerations for the instrument and system designers.

Gier, H. L.↗

Characterizing Deformable Mirrors for the MagAO-X Instrument

The MagAO-X instrument is a new extreme adaptive optics system for high-contrast imaging at visibleand near-infrared wavelengths on the Magellan Clay Telescope. A central component of this system is a 2040-actuatormicroelectromechanical deformable mirror (DM) from Boston Micromachines Corp. that operates at 3.63 kHz forhigh-order wavefront control (the tweeter). Two additional DMs from ALPAO perform the low-order (the woofer)and non-common-path science-arm wavefront correction (the NCPC DM). Prior to integration with the instrument, wecharacterized these devices using a Zygo Verifire Interferometer to measure each DM surface. We present the resultsof the characterization effort here, demonstrating the ability to drive tweeter to a flat of 6.9 nm RMS surface (and 0.56nm RMS surface within its control bandwidth), the woofer to 2.2 nm root mean square (RMS) surface, and the NCPCDM to 2.1 nm RMS surface over the MagAO-X beam footprint on each device. Using focus-diversity phase retrievalon the MagAO-X science cameras to estimate the internal instrument wavefront error (WFE), we further show that theintegrated DMs correct the instrument WFE to 18.7 nm RMS, which, combined with a 11.7% pupil amplitude RMS,produces a Strehl ratio of 0.94 at H↵

Kyle Van Gorkom↗

Further Support of the Development of Advanced Multilayer Optics Coatings for X-Ray Imaging

The Smithsonian Astrophysical Observatory (SAO) is working with Lawrence Livermore National Laboratory (LLNL) to develop Wolter-I optics for x-ray imaging applications at energies of 15-50 keV and above for National Nuclear Security Administration (NNSA) facilities. SAO work includes R&D on advanced multilayer coatings as well as fabrication and testing of Wolter multilayer coated optics. It also includes delivery of custom 3.05-meter focal length Wolter optics with response at energies of interest to Sandia National Laboratories and LLNL. The optics are fabricated using an electroform nickel replication technique which has been used to fabricate optics for X-ray astronomy satellites over the past two decades. This technique starts with a figured, polished mandrel from which the optics are replicated. To carry this technique over to fabricate optics for NNSA facilities, several additional barriers had to be overcome to deposit multilayer coatings on integral optics with radii as small as 25 mm. These breakthroughs allow fabrication of optics which meet the spatial and spectral specifications required by NNSA facilities. During this present contract period SAO delivered four custom optics to LLNL with spectral response at or near the Kα line of silver, 22.16 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Longitudinally Jointed Edge-wise Compression Honeycomb Composite Sandwich Coupon Testing and FE Analysis: Three Methods of Strain Measurement, and Comparison

Three means (i.e., typical foil strain gages, fiber optic sensors, and a digital image correlation (DIC) system) were implemented to measure strains on the back and front surfaces of a longitudinally jointed curved test article subjected to edge-wise compression testing, at NASA Goddard Space Flight Center, according to ASTM C364. The Pre-test finite element analysis (FEA) was conducted to assess ultimate failure load and predict strain distribution pattern throughout the test coupon. The predicted strain pattern contours were then utilized as guidelines for installing the strain measurement instrumentations. The strain gages and fiber optic sensors were bonded on the specimen at locations with nearly the same strain values, as close as possible to each other, so that, comparisons between the measured strains by strain gages and fiber optic sensors, as well as the DIC system are justified. The test article was loaded to failure (at approximately 38 kips), at the strain value of approximately 10,000mu epsilon As a part of this study, the validity of the measured strains by fiber optic sensors is examined against the strain gage and DIC data, and also will be compared with FEA predictions.

Farrokh, Babak↗

MicroResonators for Compacts Optical Sensors (μRCOS)

As the demand for continuous, in-situ surveillance of health of systems and environments rapidly increases, miniaturized sensors with fast responses are sought. Optical dielectric resonators supporting Whispering Gallery Modes (WGMs) have exceptional properties, like very high-power density, very narrow spectral linewidth, and extremely small mode volume. As the footprint of these sensors is drastically reduced, measurements of microvolumes samples with dramatic reduction in analysis time are possible, enabling large numbers of parallel analyses using microarrays. The high sensitivity and speed of WGM resonators combined with the ability to detect molecules in their native state have great future potential for basic and applied research such as reliable single molecule, trace-gas detection, environmental monitoring, chemical threat sensing, and biodefense Such appealing peculiarities motivated us developing WMG resonators (WGMRs) for Cavity Enhanced Absorption Spectroscopy (CEAS) for chem-bio detection. Specifically, we designed and batch-fabricated microspheres and fiber tapers for resonances excitation. We successfully detected gases (N 2 and CO 2 ) in customized environmental chambers, and bio-organisms (Inf. A and E. Coli) with integrated microfluidic systems. Background calibration and environmental isolation were always accounted for in proving the performances.

36 MATERIALS SCIENCE↗

Monitoring Small Deformations In An Instrument

Relatively simple source/detector pairs measure changes affecting optical alignment. System for monitoring small thermal, gravitational, and dynamical deformations in x-ray telescope includes two sources of infrared light, each associated with dual-axis, position-sensing photodiode. Principle of operation straightforward and applicable to monitoring of small lateral translations and/or rotations between different parts in machinery, buildings, bridges, ships, and other large structures.

Hagopian, John G.↗

A lunar based solar observatory - Rationale and concepts

The rationale for a lunar solar observatory is described and the requirements for various candidate instruments are developed. The unique characteristics of the lunar surface, its stability, low seismicity, and long unobstructed paths make it an ideal site for a large, high performance optical telescope. The capabilities of such an instrument is used, as an example (1) for the science that might be achieved from the lunar surface, (2) to identify the magnitude of the instrumentation, and (3) to indicate the technologies that must be developed if such an observatory is to become a reality.

Davis, John M.↗