Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operator approximation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Sliding friction and wear behavior of nuclear graphite in high temperature inert environment: Influence of contact load, speed and temperature

Repeated dynamic interactions of graphitic components in pebble-bed gas-cooled nuclear reactors can cause abrasive wear-induced pebble surface damage, generate hazardous fine graphite debris, and alter fuel circulation dynamics due to changes in friction behavior. Comprehensive tribological characterization of nuclear graphitic materials in conditions relevant to reactor operation is needed to assess reactor long-term safety and performance. This work reports sliding friction and wear behavior of self-mated nuclear graphite ET-10 at various elevated temperatures (650 °C and 750 °C), sliding speeds (1 and 10 mm/s) and contact loads (20 and 40 N) in a controlled argon environment. The results revealed nonmonotonic frictional behavior with a higher running-in coefficient of friction (COF) followed by a lower steady-state COF, as a result of transition from two-body abrasion to three-body abrasion along with formation of a tribofilm. A key finding of this work is the sensitivity of the running-in COF to experimental conditions; maximum running-in values were lower at either elevated temperature (0.52–0.54) or reduced sliding speed (0.51–0.54). Conversely, the steady-state COF remained invariant at approximately 0.3 across all tested parameters. Transmission electron microscopy revealed a 0.5–2.0 μm thick nanocrystalline tribofilm that was thought to be formed by the compaction of the graphitic wear debris on the contact surface during the sliding process. The nanocrystalline nature of the tribofilm was further confirmed by Raman spectroscopy. As a result, the combination of tribological testing and morphological characterization provided a mechanistic understanding of the frictional behavior of nuclear graphite upon sliding.

Friction↗

Revisiting Artifacts of Kohn–Sham Density Functionals for Biosimulation

We revisit the problem of unphysical charge density delocalization/fractionalization induced by the self-interaction error of common approximate Kohn–Sham (KS) density functional theory functionals on simulation of small to medium-sized proteins in a vacuum. Aside from producing unphysical electron densities and total energies, the vanishing of the HOMO–LUMO gap associated with the unphysical charge delocalization leads to an unphysical low-energy spectrum and catastrophic failure of most popular solvers for the KS self-consistent field (SCF) problem. We apply a robust quasi-Newton SCF solver to obtain solutions for some of these difficult cases. The anatomy of the charge delocalization is revealed by the natural deformation orbitals obtained from the density matrix difference between the Hartree–Fock and KS solutions; the charge delocalization not only can occur between charged fragments (such as in zwitterionic polypeptides) but also involves neutral fragments. The vanishing-gap phenomenon and troublesome SCF convergence are both attributed to the unphysical KS Fock operator eigenspectra of molecular fragments (e.g., amino acids or their side chains). Analysis of amino acid pairs suggests that the unphysical charge delocalization can be partially ameliorated by the use of some range-separated hybrid functionals but not by semilocal or standard hybrid functionals. Last, we demonstrate that solutions without the unphysical charge delocalization can be located even for semilocal KS functionals highly prone to such defects, but such solutions have non-Aufbau character and are unstable with respect to mixing of the non-overlapping “frontier” orbitals. Caution should be exercised when unexpectedly small (or vanishing) HOMO–LUMO gaps and atypical SCF convergence patterns (e.g., oscillatory) are observed in KS DFT simulations in any context (bio or otherwise).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of juvenile white sturgeon blade strike survival through a conventional and a novel hydropower turbine

Hydropower is a globally important renewable energy source with profound impacts on aquatic organisms, including direct injury and mortality to fish that move through hydropower facilities. While it is expected that the characteristics of turbine design and operation influence the type, frequency, and magnitude of injuries suffered by entrained fish, few direct comparisons exist to illustrate differences in fish survival outcomes for conventional and novel turbine designs. This study evaluated blade strike-associated injury and mortality rates for juvenile white sturgeon (Acipenser transmontanus) passed through a model-scale turbine equipped with a runner having conventional blade profiles (thin, straight leading edges) and the same turbine equipped with a runner designed for improved fish survival (thick, slanted leading edges). In both trials, head and turbine runner rotational speeds were matched to produce five blade peripheral speeds between 15.0 and 27.6 m/s. High-speed video was captured for all turbine passage events. Fish were assessed for injuries following passage, and mortalities were assessed immediately after passage and after 48 h. Conventional runner passage resulted in 42% to 78% survival after 48 h, with approximately one-third of all tested fish killed by severing. Under the same test conditions, immediate and 48 h survival rates through the novel runner were 100% except at the highest speed condition (95.6% survival at 48 h). These results clearly indicate that turbine design has a profound effect on fish survival, and suggest that thoughtful redesign of hydropower equipment could significantly ameliorate the risks of blade strike mortality.

13 HYDRO ENERGY↗

Can classical DEM simultaneously capture compressibility and flowability of milled biomass?

Accurate prediction of the rheological behavior of biomass is essential for the design and operation of hoppers, feeders, and storage systems in biorefineries. This study examines whether the classical, coarse-grained discrete element method (DEM) formulation can simultaneously reproduce the compressibility and flowability of milled herbaceous biomass, using Miscanthus × giganteus as a representative material. The model represents particles as rigid spheres interacting through Hertz-Mindlin elastic-frictional contacts augmented with an area-dependent cohesion term. Laboratory cyclic compression and wedge-shaped hopper discharge experiments were used as calibration benchmarks. Although the model can independently reproduce each behavior by appropriately tuning particle Young's modulus E and cohesion energy density k, an extensive parametric investigation comprising more than 600 simulations reveals that the optimal parameter regions for compression and hopper flow are distinct and non-overlapping in (E, k) space. Surrogate surface analysis further shows that the corresponding objective-function valleys exhibit similar trends but are approximately parallel and spatially offset, precluding a unified calibration within the explored domain. Sensitivity analysis indicates that compressibility is governed predominantly by stiffness and cohesion, whereas the slope of the mass flow rate-opening relation in hopper discharge is primarily controlled by tangential friction. Extensions incorporating particle size distribution and clumped-sphere representations do not eliminate the incompatibility. These results systematically reveal, for the first time, the structural limitation of simplified DEM formulations in representing biomass rheological behavior, underscoring the necessity for models incorporating additional physical mechanisms, such as particle deformability or enhanced interlocking, to achieve unified predictive capability for biomass handling behavior.

09 BIOMASS FUELS↗

Basin-scale study of CO 2 storage in stacked sequence of geological formations

Commercial scale decarbonization through carbon capture and storage may likely involve many CO 2 storage projects located in close proximity. The close proximity could raise concerns over caprock integrity associated with reservoir pressure buildup and interference among adjacent projects. Commercial-scale injection will also require large prospective CO 2 storage resource and high injectivity in the targeted storage formations. To accommodate the need for both large resource and high injectivity, project operators could consider injecting CO 2 into a stacked sequence of formations. This analysis investigates the benefits of injecting CO 2 into a vertically stacked sequence of saline formations, over injecting the same amount of CO 2 into a single saline formation, in addressing these challenges. Our analysis shows that injecting into the stacked sequence mitigates the extent of pressure buildup among the stacked formations, while still achieving the same or greater target CO 2 storage volumes. Among cases modeled, the resulting pressure buildup front is most reduced when each storage site distributes injection volumes over several wells, each of which injects a portion of the total CO 2 mass across the stacked sequence. This favorable case not only results in the smallest CO 2 aerial footprint, but also shows the largest reduction in the pressure buildup at the top of perforation at the injection wells (upwards of approximately 46% compared to the single-formation storage), the result of which is crucial to maintain caprock integrity. This analysis provides insights into required decision-making when considering multi-project deployment in a shared basin.

42 ENGINEERING↗

Performance Audit Report: Automated Meteorological Monitoring Stations, Lawrence Livermore National Laboratory

The Waste and Air Quality Offices Group at the Lawrence Livermore National Laboratory operates two main meteorological monitoring sites near Livermore, California. The primary met tower (Site 200) is located in the northwest corner of the lab and consists of a fifty-two (52) meter tower with vertical wind speed sensors, horizontal wind speed and direction sensors and air temperature sensors at fifty-two (52) meters, twenty-three (23) meters and ten (10) meters. In addition, there is a temperature and humidity probe at ten (10) meters. At two (2) meters there are upward and downward facing solar and infrared radiation sensors, an air temperature sensor, barometric pressure sensor and a temperature and relative humidity probe. At ground level there is a tipping bucket rain gauge located to the southwest of the tower. The datalogger, communication peripherals and the barometric pressure sensor are housed in a small building near the tower. The Site 300 met site is located approximately 10 miles east of Livermore within the boundary of the LLNL blast test site. This site also consists of a 52-meter tower which is configured the same as the 52-meter tower at Site 200. There is also a building at this site that houses the datalogger, communication peripherals and the barometric pressure sensor. At both Site 200 and Site 300, data are collected by Ethernet with telephone modem collection as a backup. The data collection interval for both sites is fifteen (15) minutes via workstations running Loggernet software located at the main lab facility. The audits of the Lawrence Livermore National Laboratory’s two automated meteorological stations located near Livermore, California were performed on October 24 & 25, 2023. These audits were performed under the guidelines of the Quality Assurance Handbook for Air Pollution Measurement Systems, Volume IV, Version 2 and the On-Site Meteorological Program Guidance for Regulatory Modeling Applications, U.S. EPA.

54 ENVIRONMENTAL SCIENCES↗

Design and analysis of a wake model for spatially heterogeneous flow

Abstract. Methods of turbine wake modeling are being developed to more accurately account for spatially variant atmospheric conditions within wind farms. Most current wake modeling utilities are designed to apply a uniform flow field to the entire domain of a wind farm. When this method is used, the accuracy of power prediction and wind farm controls can be compromised depending on the flow-field characteristics of a particular area. In an effort to improve strategies of wind farm wake modeling and power prediction, FLOw Redirection and Induction in Steady State (FLORIS) was developed to implement sophisticated methods of atmospheric characterization and power output calculation. In this paper, we describe an adapted FLORIS model that features spatial heterogeneity in flow-field characterization. This model approximates an observed flow field by interpolating from a set of atmospheric measurements that represent local weather conditions. The objective of this method is to capture heterogeneous atmospheric effects caused by site-specific terrain features, without explicitly modeling the geometry of the wind farm terrain. The implemented adaptations were validated by comparing the simulated power predictions generated from FLORIS to the actual recorded wind farm output from the supervisory control and data acquisition (SCADA) recordings and large eddy simulations (LESs). When comparing the performance of the proposed heterogeneous model to homogeneous FLORIS simulations, the results show a 14.6 % decrease for mean absolute error (MAE) in wind farm power output predictions for cases using wind farm SCADA data and a 18.9 % decrease in LES case studies. The results of these studies also indicate that the efficacy of the proposed modeling techniques may vary with differing site-specific operational conditions. This work quantifies the accuracy of wind plant power predictions under heterogeneous flow conditions and establishes best practices for atmospheric surveying for wake modeling.

17 WIND ENERGY↗

Analyzing the Quantum Approximate Optimization Algorithm: Ansätze, Symmetries, and Lie Algebras

The quantum approximate optimization algorithm (QAOA) has been proposed as a method to obtain approximate solutions for combinatorial optimization tasks. In this work, we study the underlying algebraic properties of three QAOA ansätze for the maximum-cut problem on connected graphs, while focusing on the generated Lie algebras as well as their invariant subspaces. Specifically, we analyze the standard QAOA ansatz as well as the orbit and multiangle ansätze. We are able to fully characterize the Lie algebras of the multiangle ansatz across arbitrary connected graphs, finding that they only fall into one of just six families. Aside from the cycle and path graphs, the Lie dimensions for every graph are exponentially large in the system size, meaning that multiangle ansätze are extremely prone to exhibiting barren plateaus. Then, a similar quasi-graph-independent Lie-algebraic characterization beyond the multiangle ansatz is impeded as the circuit exhibits additional “hidden” symmetries besides those naturally arising from a certain parity-superselection operator and all automorphisms of the considered graph. Disregarding the “hidden” symmetries, we can upper bound the dimensions of the orbit and the standard Lie algebras, and the dimensions of the associated invariant subspaces are determined via explicit character formulas. To finish, we conjecture that (for most graphs) the standard Lie algebras have only components that are either exponential or that grow, at most, polynomially with the system size. This would imply that the QAOA is either prone to barren plateaus or classically simulable. More generally, our work provides a symmetry framework and tools to analyze any desired variational quantum algorithm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A System Level Comparative Study of SecondarySide Rectifiers for UAV Wireless Power Transfer in High-Altitude Airborne Energy Platforms

Wireless power transfer (WPT) systems for unmanned aerial vehicles (UAVs) must satisfy stringent design requirements to ensure reliable operation under constraints related to efficiency, thermal performance, altitude, weight, and reliability, particularly in airborne and high-altitude environments. Thermal management becomes increasingly challenging at higher altitudes due to reduced air density, while reliability is strongly affected by the number and complexity of active components. The weight and compactness of secondary-side rectifiers directly impact UAV flight endurance and system integration, influencing energy consumption and payload allocation. These factors collectively define the practical feasibility of UAV WPT systems and guide rectifier topology selection. This paper presents a comparative and experimentally validated evaluation framework for secondary-side rectifiers under UAV-specific constraints. Three representative rectifier architectures are analyzed using component-based assessment of weight, thermal behavior, and reliability, together with experimental efficiency measurements obtained from a 1 kW WPT prototype. The results show that the single-switch active rectifier achieves the highest peak efficiency of approximately 93.2% and an overall efficiency of 91%, while also offering advantages in weight and reliability. The findings demonstrate how constraint-oriented analysis, combined with experimental validation, enables informed selection of secondary-side rectifiers for UAV wireless power transfer applications, including emerging airborne and high-altitude platforms.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Modeling and Analysis of a Heat Pump Clothes Dryer with Thermal Energy Storage

Clothes drying is an energy-intensive process that causes significant electricity consumption and carbon emissions in the US. Approximately 83% of Households in the US own a tumble clothes dryer at home and 80% of dryers are electrical resistance dryers with low energy efficiency. Heat pump technology makes it possible for highly efficient and clean drying. Additionally, the ventless design of heat pump clothes dryers (HPCD) provides more installation flexibility. HPCD involves three primary mediums: wet clothes, a closed air loop, and a refrigerant circuit. The evaporator is used to dehumidify the wet air and the condenser is used to re-heat the dry air. One of the critical technological barriers to HPCD market penetration is its long drying time, primarily due to the relatively low discharging temperature and the slow response during the warm-up period. In this study, the thermal energy storage (TES) technology is adopted to address this challenge by providing pre-heating of air prior to the condenser to increase the operating temperature of the process air. The heat pump will charge the phase change material (PCM) in the TES device with heating energy during clothes washing and the PCM will discharge the stored heat to facilitate air heating during clothes drying. To analyze the optimal design and potential for energy saving and drying time reduction, a mathematical model of the HPCD system was developed. The HPCD is a highly dynamic system with a coupled heat and mass transfer and heat pumping cycle. This paper provides solutions to simulate the transient behavior of the system while maintaining low computational cost. The modeling result indicates reduced energy consumption and drying time by integrating TES with HPCD, as compared to electrical resistance dryers. The study can provide significant insights into improving building flexibility with TES and smart appliances.

Liu, Xiaoli↗

Field demonstration and implementation analysis of model predictive control in an office HVAC system

Model Predictive Control (MPC) is a promising technique to address growing needs for heating, ventilation, and air-conditioning (HVAC) systems to operate more efficiently and with greater flexibility. However, due to a number of factors, including the required implementation expertise, lack of high quality data, and a risk-adverse industry, MPC has yet to gain widespread adoption. While many previous studies have shown the advantages of MPC, few analyzed the implementation effort and associated practical challenges. In addition, previous work has developed an open-source, Modelica-based tool-chain that automatically generates optimal control, parameter estimation, and state estimation problems aimed at facilitating MPC implementation. Therefore, this study demonstrates usage of this tool-chain to implement MPC in a real office building, discusses practical challenges of implementing MPC, and estimates the implementation effort associated with various tasks in order to inform the development of future workflows and serve as an initial benchmark for their impact on reducing implementation effort. This study finds that the implemented MPC saves approximately 40% of HVAC energy over the existing control during a two-month trial period and that tasks related to data collection and controller deployment activities can each require as much effort as model generation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of self-magnetic pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories. I. Diode dynamics, DC heating to extend radiation pulse

Radiographic diodes focus on an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the six-cavity radiographic integrated test stand (RITS-6) inductive voltage adder driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode–cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analysis of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below approximately few millimeters. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle behavior of SMP shots is made to lend credence to the inference. We report there is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Eigenstate thermalization in ( 2 + 1 )-dimensional SU(2) lattice gauge theory

We present preliminary numerical evidence for the hypothesis that the Hamiltonian SU(2) gauge theory discretized on a lattice obeys the eigenstate thermalization hypothesis (ETH). To do so we study three approximations: (a) a linear plaquette chain in a reduced Hilbert space limiting the electric field basis to j = 0 , 1 2 , (b) a two-dimensional honeycomb lattice with periodic or closed boundary condition and the same Hilbert space constraint, and (c) a chain of only three plaquettes but such a sufficiently large electric field Hilbert space ( j ≤ 7 2 ) that convergence of all energy eigenvalues in the analyzed energy window is observed. While an unconstrained Hilbert space is required to reach the continuum limit of SU(2) gauge theory, numerical resource constraints do not permit us to realize this requirement for all values of the coupling constant and large lattices. In each of the three studied cases we check first for random matrix theory (RMT) behavior in the eigenenergy spectrum and then analyze the diagonal as well as the off-diagonal matrix elements between energy eigenstates for a few operators. Within current uncertainties all results for (a), (b) and (c) agree with ETH predictions. Furthermore, we find the off-diagonal matrix elements of the electric energy operator exhibit RMT behavior in frequency windows that are small enough in (b) and (c). To unambiguously establish ETH behavior and determine for which class of operators it applies, an extension of our investigations is necessary. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrogen Energy Storage System at Borrego Springs Towards an H2 Enabled 100 Renewable Microgrid

San Diego Gas & Electric's Borrego Springs Microgrid is one of the largest microgrids in the USA, serving 2500 residential customers, 300 commercial and industrial customers, and has a peak demand of approximately 14 MW. This microgrid is located at the end of a long transmission line, and is subjected to extreme weather events like storms, wildfires, and flooding, which frequently cause grid outages. The microgrid currently relies on 3.65 MW of diesel-powered generators to provide grid-forming services during these outages, which results in greenhouse gas and criteria pollutant emissions. However, the microgrid has access to approximately 37 MW of installed solar generation and struggles with overgeneration and curtailment. 1.5 MW/4.5 MWh of grid-scale batteries have been installed to capture some the overgeneration and provide resiliency, but a longer-duration low-greenhouse gas emission energy storage solution is needed. In our project, the team will evaluate in the lab and demonstrate in the field a grid-forming fuel cell inverter that can provide grid-forming services while utilizing hydrogen's energy storage scalability. We will first utilize NREL's Renewable Energy Integration and Optimization (REopt) platform to perform analyses on future microgrid scenarios that use hydrogen assets to reduce or eliminate the need for diesel backup generators. We will then evaluate the grid-forming inverter through power hardware-in-the-loop and controller hardware-in-the-loop experiments at ARIES, and de-risk the field deployment and operation of hydrogen assets in the microgrid setting. Finally, this project will demonstrate the operation of the fuel cell inverter and updated microgrid controller by operating in grid-forming mode in the Borrego Springs microgrid.

Borrego Springs↗

Hydrogen Energy Storage System at Borrego Springs Towards an H2 Enabled 100% Renewable Microgrid

San Diego Gas & Electric's Borrego Springs Microgrid is one of the largest microgrids in the USA, serving 2500 residential customers, 300 commercial and industrial customers, and has a peak demand of approximately 14 MW. This microgrid is located at the end of a long transmission line, and is subjected to extreme weather events like storms, wildfires, and flooding, which frequently cause grid outages. The microgrid currently relies on 3.65 MW of diesel-powered generators to provide grid-forming services during these outages, which results in greenhouse gas and criteria pollutant emissions. However, the microgrid has access to approximately 37 MW of installed solar generation and struggles with overgeneration and curtailment. 1.5 MW/4.5 MWh of grid-scale batteries have been installed to capture some the overgeneration and provide resiliency, but a longer-duration low-greenhouse gas emission energy storage solution is needed. In our project, the team will evaluate in the lab and demonstrate in the field a grid-forming fuel cell inverter that can provide grid-forming services while utilizing hydrogen's energy storage scalability. We will first utilize NREL's Renewable Energy Integration and Optimization (REopt) platform to perform analyses on future microgrid scenarios that use hydrogen assets to reduce or eliminate the need for diesel backup generators. We will then evaluate the grid-forming inverter through power hardware-in-the-loop and controller hardware-in-the-loop experiments at ARIES, and de-risk the field deployment and operation of hydrogen assets in the microgrid setting. Finally, this project will demonstrate the operation of the fuel cell inverter and updated microgrid controller by operating in grid-forming mode in the Borrego Springs microgrid.

blackstart with fuel cells↗

Ion Exchange Processing of AW-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AW-105 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 9.2 L of diluted and filtered supernate from Tank 241-AW-105 (hereafter referred to as AW-105) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AW-105 tank waste to meet this criterion, only 0.225% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 445. Testing with AW-105 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 83% Cs breakthrough after processing ~1500 BVs of feed; the 50% Cs breakthrough was interpolated from the breakthrough data and occurred at 1041 BVs. Despite the AW-105 having a significantly higher K concentration (0.55 M compared to 0.10 M), testing compared to previous AP-107 ion exchange column testing at 16 °C showed no difference in BVs processed to reach the WAC on the lead column and only an approximate ~20 BV decrease in volume processed to reach the WAC limit on the lag column. The negligible differences in capacity despite the 5x concentration differences in K was determined to be due to the significantly lower NO3 concentration in the AW-105 supernate compared to the AP-107 tank waste matrix. A comparison in breakthrough curves for the two tests also indicated slightly faster kinetic behavior in the AW-105, with the variations in feed matrices (lower NO3 concentration) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 772 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 675 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 1.10×10 1 µCi/mL, or 14.13 % Cs breakthrough, after processing all 1500 BVs of feed. The polish column processed nominally 830 BVs and reached 2.10×10 -1 µCi/mL, or 0.27 % Cs breakthrough at the conclusion of the test. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗