Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Multiple”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Extend NdJ relationship with the size, multiple exchanges and Dzyaloshinskii-Moriya interaction for Néel skyrmions in hexagonal magnetic interfaces

For the integration with other parts of spintronic devices, it is desired to minimize the size of skyrmions to a nanometer scale. To provide a theoretical guidance for this endeavour, we established an extended NdJ relationship between the skyrmion size and fundamental magnetic properties of two-dimensional hexagonal ferromagnetic lattices, including multiple exchanges between different neighbors (J 1 -J 4 ), Dzyaloshinskii-Moriya interactions (d 1 and d 2 ) and on-site magnetic anisotropy energy. We demonstrated the applicability of this approach through density functional theory and spin spiral calculations for several interface, e.g., Co/Gra, Rh/Gra, Co/Pt 3 and MgO/Co/Pt 3 , and showed that the size of Néel skyrmions can be effectively reduced by either enhancing d or more conveniently reducing J through cancelation of J i s.

36 MATERIALS SCIENCE↗

Cross-scale efficient tensor contractions for coupled cluster computations through multiple programming model backends

Coupled-cluster methods provide highly accurate models of molecular structure through explicit numerical calculation of tensors representing the correlation between electrons. These calculations are dominated by a sequence of tensor contractions, motivating the development of numerical libraries for such operations. While based on matrix–matrix multiplication, these libraries are specialized to exploit symmetries in the molecular structure and in electronic interactions, and thus reduce the size of the tensor representation and the complexity of contractions. The resulting algorithms are irregular and their parallelization has been previously achieved via the use of dynamic scheduling or specialized data decompositions. We introduce our efforts to extend the Libtensor framework to work in the distributed memory environment in a scalable and energy-efficient manner. We achieve up to 240× speedup compared with the optimized shared memory implementation of Libtensor. We attain scalability to hundreds of thousands of compute cores on three distributed-memory architectures (Cray XC30 and XC40, and IBM Blue Gene/Q), and on a heterogeneous GPU-CPU system (Cray XK7). As the bottlenecks shift from being compute-bound DGEMM's to communication-bound collectives as the size of the molecular system scales, we adopt two radically different parallelization approaches for handling load-imbalance, tasking and bulk synchronous models. Nevertheless, we preserve a unified interface to both programming models to maintain the productivity of computational quantum chemists.

97 MATHEMATICS AND COMPUTING↗

Multiple nonlinear dielectric resonance of ultra-long silver trimolybdate nanowires

The silver molybdate nanowires (NWs) have been synthesized and characterized. The multiple dielectric resonant peaks of the nanocomposites filled with silver molybdate nanowires have been studied from 2 to 18 GHz. The as-established equivalent circuit model of the silver molybdate nanowires were employed to explain the nonlinear dielectric resonant behavior. - Graphical abstract: The ultra-long silver trimolybdate nanowires were synthesized and the dielectric peoperties of the products were studied from 2 to 18 GHz. The as-established equivalent circuit model of the silver molybdate nanowires were employed to explain the nonlinear dielectric resonant behavior. Highlights: • The silver molybdate nanowires have been synthesized and characterized. • The dielectric properties of the silver molybdate/ paraffin nanocomposites have been studied. • Higher concentration of silver trimolybdate enhances the dielectric properties of composite. • The dielectric behaviors were explained based on the as-established equivalent circuit mode.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stability of molybdenum nanoparticles in Sn-3.8Ag-0.7Cu solder during multiple reflow and their influence on interfacial intermetallic compounds

This work investigates the effects of molybdenum nanoparticles on the growth of interfacial intermetallic compound between Sn-3.8Ag-0.7Cu solder and copper substrate during multiple reflow. Molybdenum nanoparticles were mixed with Sn-3.8Ag-0.7Cu solder paste by manual mixing. Solder samples were reflowed on a copper substrate in a 250 Degree-Sign C reflow oven up to six times. The molybdenum content of the bulk solder was determined by inductive coupled plasma-optical emission spectrometry. It is found that upon the addition of molybdenum nanoparticles to Sn-3.8Ag-0.7Cu solder, the interfacial intermetallic compound thickness and scallop diameter decreases under all reflow conditions. Molybdenum nanoparticles do not appear to dissolve or react with the solder. They tend to adsorb preferentially at the interface between solder and the intermetallic compound scallops. It is suggested that molybdenum nanoparticles impart their influence on the interfacial intermetallic compound as discrete particles. The intact, discrete nanoparticles, by absorbing preferentially at the interface, hinder the diffusion flux of the substrate and thereby suppress the intermetallic compound growth. - Highlights: Black-Right-Pointing-Pointer Mo nanoparticles do not dissolve or react with the SAC solder during reflow. Black-Right-Pointing-Pointer Addition of Mo nanoparticles results smaller IMC thickness and scallop diameter. Black-Right-Pointing-Pointer Mo nanoparticles influence the interfacial IMC through discrete particle effect.

36 MATERIALS SCIENCE↗

Mechanical characterization of Ti-6Al-4V titanium alloy at multiple length scales using spherical indentation stress-strain measurements

Recent advances in spherical indentation stress-strain protocols and analyses have demonstrated the capability for measuring reliably the local mechanical responses in polycrystalline metal samples at different length scales, ranging from sub-micron (regions within individual grains) to several hundreds of microns (regions covering several grains). These recent advances have now made it possible to study systematically the mechanical behavior of a single material system at different length scales, with tremendous potential to obtain new insights into the role of individual phases, interfaces, and other microscale constituents on the macroscale mechanical response of the material. In this paper, we report spherical indentation stress-strain measurements with different indenter sizes (microns to millimeters) on Ti-6Al-4V (Ti-64) which capture the mechanical response of single phase alpha-Ti-64, single colony (alpha-beta), few colonies, and many colonies of Ti-64. The results show that the average mechanical response (indentation modulus and yield strength) from multiple indentations remains relatively unchanged from single phase alpha to many colonies of Ti-64, while the variance in the response decreases with indenter size. In conclusion, the work-hardening response in indentation tests follows a similar behavior up to indentation zones of many colonies, which shows significantly higher work hardening rates.

36 MATERIALS SCIENCE↗

InAs{sub 0.45}P{sub 0.55}/InP strained multiple quantum wells intermixed by inductively coupled plasma etching

The intermixing effect on InAs{sub 0.45}P{sub 0.55}/InP strained multiple quantum wells (SMQWs) by inductively coupled plasma (ICP) etching and rapid thermal annealing (RTA) is investigated. Experiments show that the process of ICP etching followed RTA induces the blue shift of low temperature photoluminescence (PL) peaks of QWs. With increasing etching depth, the PL intensities are firstly enhanced and then diminished. This phenomenon is attributed to the variation of surface roughness and microstructure transformation inside the QW structure during ICP processing.

36 MATERIALS SCIENCE↗

Enhanced H{sub 2}S gas sensing properties of multiple-networked Pd-doped SnO{sub 2}-core/ZnO-shell nanorod sensors

Pd-doped SnO{sub 2}-core/ZnO-shell nanorods were synthesized by using a three-step process: thermal evaporation of Sn powders in an oxygen atmosphere, atomic layer deposition of ZnO, and Pd diffusion followed by annealing. The sensitivity of the multiple networked SnO{sub 2}-core/ZnO-shell nanorod sensor to H{sub 2}S gas was found to be improved further significantly by Pd doping. The Pd-doped SnO{sub 2}-core/ZnO-shell nanorod sensor showed sensitivities of 6.4, 15.4, and 36.2% at H{sub 2}S concentrations of 20, 50, and 100 ppm at room temperature. The sensitivity of the nanorods was improved by more than 10 times at a H{sub 2}S concentration of 100 ppm. The sensitivity enhancement of the SnO{sub 2}-core/ZnO-shell nanorods by Pd doping may be attributed to the spillover effect, active reaction site generation, and the enhancement of chemisorption and dissociation of gas.

36 MATERIALS SCIENCE↗

Inducing multiple functionalities in ZnS nanoparticles by doping Ni{sup +2} ions

Graphical abstract: Figure shows spherical ZnS nanoparticle (light red) containing Ni as dopant ions (light green inside) exhibiting both optical (straight lines) as well as magnetic (elliptical field lines) activities simultaneously. Highlights: ► A simple method has been adopted to synthesize Ni{sup +2} doped ZnS nanoparticles. ► The enhancing and quenching of the PL intensity depended upon ‘purity of the phase’. ► The change in packing of the molecules in ZnS NPs directly depended on concentration of dopant. ► Magnetic and optical properties were found to be dopant dependent (e.g. Ni{sup +2} ions). ► Proper choice of solvent for synthesis shows a marked effect on magnetism. - Abstract: In this study, we propose that it is possible to induce multiple functionalities such as optical activity, electrical conductance and magnetism in single ZnS/Ni nanoparticles and exploit the same by only changing the external stimuli such as magnetic field, wavelength of light, electric field etc. Such type of material finds great significance in the field of electronics as well as in bioimaging. For the purpose, we have synthesized cubic ZnS:Ni{sup 2+} nanoparticles (NPs) using a simple wet-chemical method. Synthesized ZnS:Ni{sup 2+} NPs had been characterized by X-ray diffraction pattern (XRD) and energy dispersive X-ray (EDX) analysis. The amounts of Ni and Zn in the material were determined by inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Morphology of the NPs is studied by transmission electron microscopy (TEM). Optical studies are carried out using UV–visible (UV–Vis) and Photoluminescence (PL) spectroscopies. Quantum efficiency of the material was also computed. The enhancement and quenching of the PL intensity are correlated with the ‘purity of the phase’. It is observed that change in packing of the molecules of the host material directly depended on concentration of dopant ion. The thermal study of the material was carried out using differential scanning calorimetry (DSC) to support the earlier proposition. Magnetic hysteresis behavior was studied using vibrating sample magnetometer (VSM). An interesting phenomenon of defect-induced magnetism was observed, which was enhanced on doping with Ni{sup +2}.

36 MATERIALS SCIENCE↗

Pd modified prussian blue frameworks: Multiple electron transfer pathways for improving catalytic activity toward hydrogenation of nitroaromatics

Prussian blue analogs (PBAs) exhibit potential as low-cost and eco-friendly nanocatalysts that can be fabricated with ease. However, the PBA framework structure suffers from poor electronic conductivity, which limits the catalytic efficiency for this class of materials. Noble metals represent an alternative class of materials that display inherent catalytic activity but suffer from aggregation, ultimately reducing the amount of accessible catalytic sites. Herein, we demonstrate a combinatory approach that circumvents the known disadvantages with these classes of catalytic materials in which PBA-supported nanocatalysts were synthesized. These composite materials exhibit excellent catalytic activity for the reduction of nitroaromatics to aminoaromatics while displaying long-term cycling stability, which is attributed to the availability of multiple electron transfer pathways. Overall, this work opens the study on the assembly of PBA-supported heterogeneous nanocatalysts and potentially paves the way toward future applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A compact design for an electric driven hydraulic gear machine capable of multiple quadrant operation

This paper presents an innovative design of an integrated electro-hydraulic (EH) flow generation unit able to operate in multiple quadrants. The proposed unit is composed of a hydraulic machine which can operate in either pumping or motoring mode, and an electric machine, which can operate as electric motor or generator. The adopted morphological integration of the two unit fulfills the goals of maximizing compactness, power to weight ratio, energy efficiency and quietness. Furthermore, the design results from a numerical optimization procedure that includes detailed simulation of both the electric machine and the hydraulic machine, using simulation tools previously developed by the authors, but combined for the first time in this work. After describing the optimization procedure, the paper focuses on the design integration aspects of the novel unit. A 9 kW prototype of the integrated unit was also fabricated and tested to verify its performance. Tests results show a measured overall energy efficiency up to 69%, demonstrating the potentials of the proposed concept, despite some limitations present in the first prototypes which could be addressed in future design refinements.

42 ENGINEERING↗

Generation of Composite Dose and Biological Effective Dose (BED) Over Multiple Treatment Modalities and Multistage Planning Using Deformable Image Registration

Currently there are no commercially available tools to generate composite plans across different treatment modalities and/or different planning image sets. Without a composite plan, it may be difficult to perform a meaningful dosimetric evaluation of the overall treatment course. In this paper, we introduce a method to generate composite biological effective dose (BED) plans over multiple radiotherapy treatment modalities and/or multistage plans, using deformable image registration. Two cases were used to demonstrate the method. Case I was prostate cancer treated with intensity-modulated radiation therapy (IMRT) and a permanent seed implant. Case II involved lung cancer treated with two treatment plans generated on two separate computed tomography image sets. Thin-plate spline or optical flow methods were used as appropriate to generate deformation matrices. The deformation matrices were then applied to the dose matrices and the resulting physical doses were converted to BED and added to yield the composite plan. Cell proliferation and sublethal repair were considered in the BED calculations. The difference in BED between normal tissues and tumor volumes was accounted for by using different BED models, {alpha}/{beta} values, and cell potential doubling times. The method to generate composite BED plans presented in this paper provides information not available with the traditional simple dose summation or physical dose summation. With the understanding of limitations and uncertainties of the algorithms involved, it may be valuable for the overall treatment plan evaluation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Intensity-modulated radiosurgery with rapidarc for multiple brain metastases and comparison with static approach

Rotational RapidArc (RA) and static intensity-modulated radiosurgery (IMRS) have been used for brain radiosurgery. This study compares the 2 techniques from beam delivery parameters and dosimetry aspects for multiple brain metastases. Twelve patients with 2-12 brain lesions treated with IMRS were replanned using RA. For each patient, an optimal 2-arc RA plan from several trials was chosen for comparison with IMRS. Homogeneity, conformity, and gradient indexes have been calculated. The mean dose to normal brain and maximal dose to other critical organs were evaluated. It was found that monitor unit (MU) reduction by RA is more pronounced for cases with larger number of brain lesions. The MU-ratio of RA and IMRS is reduced from 104% to 39% when lesions increase from 2 to 12. The dose homogeneities are comparable in both techniques and the conformity and gradient indexes and critical organ doses are higher in RA. Treatment time is greatly reduced by RA in intracranial radiosurgery, because RA uses fewer MUs, fewer beams, and fewer couch angles.

61 RADIATION PROTECTION AND DOSIMETRY↗

A single-gradient junction technique to replace multiple-junction shifts for craniospinal irradiation treatment

Craniospinal irradiation (CSI) requires abutting fields at the cervical spine. Junction shifts are conventionally used to prevent setup error–induced overdosage/underdosage from occurring at the same location. This study compared the dosimetric differences at the cranial-spinal junction between a single-gradient junction technique and conventional multiple-junction shifts and evaluated the effect of setup errors on the dose distributions between both techniques for a treatment course and single fraction. Conventionally, 2 lateral brain fields and a posterior spine field(s) are used for CSI with weekly 1-cm junction shifts. We retrospectively replanned 4 CSI patients using a single-gradient junction between the lateral brain fields and the posterior spine field. The fields were extended to allow a minimum 3-cm field overlap. The dose gradient at the junction was achieved using dose painting and intensity-modulated radiation therapy planning. The effect of positioning setup errors on the dose distributions for both techniques was simulated by applying shifts of ± 3 and 5 mm. The resulting cervical spine doses across the field junction for both techniques were calculated and compared. Dose profiles were obtained for both a single fraction and entire treatment course to include the effects of the conventional weekly junction shifts. Compared with the conventional technique, the gradient-dose technique resulted in higher dose uniformity and conformity to the target volumes, lower organ at risk (OAR) mean and maximum doses, and diminished hot spots from systematic positioning errors over the course of treatment. Single-fraction hot and cold spots were improved for the gradient-dose technique. The single-gradient junction technique provides improved conformity, dose uniformity, diminished hot spots, lower OAR mean and maximum dose, and one plan for the entire treatment course, which reduces the potential human error associated with conventional 4-shifted plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

A planning comparison of 3-dimensional conformal multiple static field, conformal arc, and volumetric modulated arc therapy for the delivery of stereotactic body radiotherapy for early stage lung cancer

The primary objective of this study was to compare dosimetric variables as well as treatment times of multiple static fields (MSFs), conformal arcs (CAs), and volumetric modulated arc therapy (VMAT) techniques for the treatment of early stage lung cancer using stereotactic body radiotherapy (SBRT). Treatments of 23 patients previously treated with MSF of 48 Gy to 95% of the planning target volume (PTV) in 4 fractions were replanned using CA and VMAT techniques. Dosimetric parameters of the Radiation Therapy Oncology Group (RTOG) 0915 trial were evaluated, along with the van't Riet conformation number (CN), monitor units (MUs), and actual and calculated treatment times. Paired t-tests for noninferiority were used to compare the 3 techniques. CA had significant dosimetric improvements over MSF for the ratio of the prescription isodose volume to PTV (R{sub 100%}, p < 0.0001), the maximum dose 2 cm away from the PTV (D{sub 2} {sub cm}, p = 0.005), and van't Riet CN (p < 0.0001). CA was not statistically inferior to MSF for the 50% prescription isodose volume to PTV (R{sub 50%}, p = 0.05). VMAT was significantly better than CA for R{sub 100%} (p < 0.0001), R{sub 50%} (p < 0.0001), D{sub 2} {sub cm} (p = 0.006), and CN (p < 0.0001). CA plans had significantly shorter treatment times than those of VMAT (p < 0.0001). Both CA and VMAT planning showed significant dosimetric improvements and shorter treatment times over those of MSF. VMAT showed the most favorable dosimetry of all 3 techniques; however, the dosimetric effect of tumor motion was not evaluated. CA plans were significantly faster to treat, and minimize the interplay of tumor motion and dynamic multileaf collimator (MLC) motion effects. Given these results, CA has become the treatment technique of choice at our facility.

61 RADIATION PROTECTION AND DOSIMETRY↗

Treatment planning strategy for whole-brain radiotherapy with hippocampal sparing and simultaneous integrated boost for multiple brain metastases using intensity-modulated arc therapy

Purpose: To retrospectively evaluate the accuracy, plan quality and efficiency of intensity-modulated arc therapy (IMAT) for hippocampal sparing whole-brain radiotherapy (HS-WBRT) with simultaneous integrated boost (SIB) in patients with multiple brain metastases (m-BM). Materials and methods: A total of 5 patients with m-BM were retrospectively replanned for HS-WBRT with SIB using IMAT treatment planning. The hippocampus was contoured on diagnostic T1-weighted magnetic resonance imaging (MRI) which had been fused with the planning CT image set. The hippocampal avoidance zone (HAZ) was generated using a 5-mm uniform margin around the paired hippocampi. The m-BM planning target volumes (PTVs) were contoured on T1/T2-weighted MRI registered with the 3D planning computed tomography (CT). The whole-brain planning target volume (WB-PTV) was defined as the whole-brain tissue volume minus HAZ and m-BM PTVs. Highly conformal IMAT plans were generated in the Eclipse treatment planning system for Novalis-TX linear accelerator consisting of high-definition multileaf collimators (HD-MLCs: 2.5-mm leaf width at isocenter) and 6-MV beam. Prescription dose was 30 Gy for WB-PTV and 45 Gy for each m-BM in 10 fractions. Three full coplanar arcs with orbit avoidance sectors were used. Treatment plans were evaluated using homogeneity (HI) and conformity indices (CI) for target coverage and dose to organs at risk (OAR). Dose delivery efficiency and accuracy of each IMAT plan was assessed via quality assurance (QA) with a MapCHECK device. Actual beam-on time was recorded and a gamma index was used to compare dose agreement between the planned and measured doses. Results: All 5 HS-WBRT with SIB plans met WB-PTV D{sub 2%}, D{sub 98%}, and V{sub 30} {sub Gy} NRG-CC001 requirements. The plans demonstrated highly conformal and homogenous coverage of the WB-PTV with mean HI and CI values of 0.33 ± 0.04 (range: 0.27 to 0.36), and 0.96 ± 0.01 (range: 0.95 to 0.97), respectively. All 5 hippocampal sparing patients met protocol guidelines with maximum dose and dose to 100% of hippocampus (D{sub 100%}) less than 16 and 9 Gy, respectively. The dose to the optic apparatus was kept below protocol guidelines for all 5 patients. Highly conformal and homogenous radiosurgical dose distributions were achieved for all 5 patients with a total of 33 brain metastases. The m-BM PTVs had a mean HI = 0.09 ± 0.02 (range: 0.07 to 0.19) and a mean CI = 1.02 ± 0.06 (range: 0.93 to 1.2). The total number of monitor units (MU) was, on average, 1677 ± 166. The average beam-on time was 4.1 ± 0.4 minute . The IMAT plans demonstrated accurate dose delivery of 95.2 ± 0.6%, on average, for clinical gamma passing rate with 2%/2-mm criteria and 98.5 ± 0.9%, on average, with 3%/3-mm criteria. Conclusions: All hippocampal sparing plans were considered clinically acceptable per NRG-CC001 dosimetric compliance criteria. IMAT planning provided highly conformal and homogenous dose distributions for the WB-PTV and m-BM PTVs with lower doses to OAR such as the hippocampus. These results suggest that HS-WBRT with SIB is a clinically feasible, fast, and effective treatment option for patients with a relatively large numbers of m-BM lesions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Targeting accuracy of single-isocenter intensity-modulated radiosurgery for multiple lesions

To investigate the targeting accuracy of intensity-modulated SRS (IMRS) plans designed to simultaneously treat multiple brain metastases with a single isocenter. A home-made acrylic phantom able to support a film (EBT3) in its coronal plane was used. The phantom was CT scanned and three coplanar small targets (a central and two peripheral) were outlined in the Eclipse system. Peripheral targets were 6 cm apart from the central one. A reference IMRS plan was designed to simultaneously treat the three targets, but only a single isocenter located at the center of the central target was used. After positioning the phantom on the linac using the room lasers, a CBCT scan was acquired and the reference plan were mapped on it, by placing the planned isocenter at the intersection of the landmarks used in the film showing the linac isocenter. The mapped plan was then recalculated and delivered. The film dose distribution was derived using a cloud computing application ( (www.radiochromic.com)) that uses a triple-channel dosimetry algorithm. Comparison of dose distributions using the gamma index (5%/1 mm) were performed over a 5 × 5 cm{sup 2} region centered over each target. 2D shifts required to get the best gamma passing rates on the peripheral target regions were compared with the reported ones for the central target. The experiment was repeated ten times in different sessions. Average 2D shifts required to achieve optimal gamma passing rates (99%, 97%, 99%) were 0.7 mm (SD: 0.3 mm), 0.8 mm (SD: 0.4 mm) and 0.8 mm (SD: 0.3 mm), for the central and the two peripheral targets, respectively. No statistical differences (p > 0.05) were found for targeting accuracy between the central and the two peripheral targets. The study revealed a targeting accuracy within 1 mm for off-isocenter targets within 6 cm of the linac isocenter, when a single-isocenter IMRS plan is designed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation therapy of synchronous bilateral breast carcinoma (SBBC) using multiple techniques

The purpose of this study was to establish intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) treatment plans for synchronous bilateral breast cancer (SBBC) and to compare those plans with the previous treatment plans using 3D conformal radiation therapy (3DCRT). The differences among the treatments were also statistically compared regarding dosimetry distribution and treatment efficiency. The research was conducted with 10 SBBC patients. The study established IMRT (12 fields with a single isocenter) and VMAT (2 partial arcs with a single isocenter) treatment plans for SBBC patients and then compared those plans with 3DCRT (8 fields with multiple isocenters). The plans were evaluated based on a dose-volume histogram analysis. For planning target volumes (PTVs), the mean doses and the values of V{sub 95%}, V{sub 105%}, conformity index, and homogeneity index were reported. For the organs at risk, the analysis included the mean dose, maximum dose, and V{sub XGy}, depending on the organs (lungs, heart, and liver). To objectively evaluate the efficiency of the treatment plans, each plan's beam times, treatment times (including set-up time), and monitor units were compared. Tukey test and one-way analysis of variance were used to compare the PTV and organs at risk values of the 3 techniques. Additionally, the independent-samples t-test was used to compare the 2 techniques (IMRT and VMAT) based on the values of Rt. PTV and Lt. PTV (p mean and of approximately 5.7% in V{sub 95%} dose distribution compared with 3DCRT. In comparison to VMAT, 3DCRT showed about 3.0% higher dose distribution in D{sub mean} and V{sub 95%}. IMRT was the best in terms of conformity index and homogeneity index (p 30Gy and V{sub 40Gy} was approximately 70% lower for IMRT and approximately 40% lower for VMAT than for 3DCRT. For distribution volumes of low doses such as V{sub 5%} and V{sub 10%}, that for 3DCRT was approximately 60% smaller than for IMRT and approximately 70% smaller than for VMAT. Comparison between IMRT and VMAT showed that the IMRT was superior in all distribution factors. VMAT showed better treatment efficiency than 3DCRT or IMRT. Among the SBBC radiotherapy treatment plans, IMRT was superior to 3DCRT and VMAT in terms of PTV dose distribution, whereas VMAT showed the most outstanding treatment efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synthesis and characterization of magnetic ionic liquids containing multiple paramagnetic lanthanide and transition metal centers and functionalized diglycolamide ligands

Magnetic ionic liquids (MILs) containing paramagnetic centers have gained widespread recognition as sustainable solvents due to their ability to respond to an external magnetic field. The physico-chemical properties of MILs are dependent on the choice of anion/cation ligands and metal centers; the search for highly tunable ligands and precursors that can confer favorable characteristics, such as low viscosity, is ongoing. Diglycolamides employed as cationic ligands have been previously shown to form hydrophobic MILs that can simultaneously incorporate multiple lanthanide metal centers in both the anion/cation. Despite their enhanced magnetic susceptibility, the effect of diglycolamide chemical structure modifications on the physico-chemical properties of MILs has not been thoroughly studied. Additionally, the possibility of forming diglycolamide-based MILs with popularly employed transition metals has not been investigated and combinations that can simultaneously embed two different types of metal centers in both the anion/cation have not been explored. In this study, thirty (30) MILs comprised of lanthanide and transition metals were synthesized by examining their chelation to both straight-chained and branched diglycolamides. Here, transition metal-based MILs were found to possess high thermal stabilities up to 235 °C compared to 192 °C for those comprised of lanthanides. While MILs comprised of rare-earth metal centers exhibited the lowest viscosities, substituting lanthanides with transition metals in just the anion or cation resulted in enhanced thermal stability and reduced viscosity. The effective magnetic moment for these MILs varied between 4.71 and 21.08 µ B and was much higher compared to all previous classes of MILs prepared using the same metals. Results from this study explore all possible modifications that can be made to these MILs in an effort to demonstrate their structural tunability, which is often highly desirable in various applications, including organic synthesis and chemical separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗