Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Adaptive hybrid simulations for multiscale stochastic reaction networks

The probability distribution describing the state of a Stochastic Reaction Network (SRN) evolves according to the Chemical Master Equation (CME). It is common to estimate its solution using Monte Carlo methods such as the Stochastic Simulation Algorithm (SSA). In many cases, these simulations can take an impractical amount of computational time. Therefore, many methods have been developed that approximate sample paths of the underlying stochastic process and estimate the solution of the CME. A prominent class of these methods include hybrid methods that partition the set of species and the set of reactions into discrete and continuous subsets. Such a partition separates the dynamics into a discrete and a continuous part. Simulating such a stochastic process can be computationally much easier than simulating the exact discrete stochastic process with SSA. Moreover, the quasi-stationary assumption to approximate the dynamics of fast subnetworks can be applied for certain classes of networks. However, as the dynamics of a SRN evolves, these partitions may have to be adapted during the simulation. We develop a hybrid method that approximates the solution of a CME by automatically partitioning the reactions and species sets into discrete and continuous components and applying the quasi-stationary assumption on identifiable fast subnetworks. Our method does not require any user intervention and it adapts to exploit the changing timescale separation between reactions and/or changing magnitudes of copy-numbers of constituent species. We demonstrate the efficiency of the proposed method by considering examples from systems biology and showing that very good approximations to the exact probability distributions can be achieved in significantly less computational time. This is especially the case for systems with oscillatory dynamics, where the system dynamics change considerably throughout the time-period of interest.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE LYOT PROJECT DIRECT IMAGING SURVEY OF SUBSTELLAR COMPANIONS: STATISTICAL ANALYSIS AND INFORMATION FROM NONDETECTIONS

The Lyot project used an optimized Lyot coronagraph with extreme adaptive optics at the 3.63 m Advanced Electro-Optical System telescope to observe 86 stars from 2004 to 2007. In this paper, we give an overview of the survey results and a statistical analysis of the observed nondetections around 58 of our targets to place constraints on the population of substellar companions to nearby stars. The observations did not detect any companion in the substellar regime. Since null results can be as important as detections, we analyzed each observation to determine the characteristics of the companions that can be ruled out. For this purpose, we use a Monte Carlo approach to produce artificial companions and determine their detectability by comparison with the sensitivity curve for each star. All the non-detection results are combined using a Bayesian approach and we provide upper limits on the population of giant exoplanets and brown dwarfs for this sample of stars. Our nondetections confirm the rarity of brown dwarfs around solar-like stars and we constrain the frequency of massive substellar companions (M>40 M{sub J}) at orbital separation between and 10 and 50 AU to be {approx_lt}20%.

79 ASTRONOMY AND ASTROPHYSICS↗

Local cation order and ferrimagnetism in compositionally complex spinel ferrites

We present an exploration of a family of compositionally complex cubic spinel ferrites featuring combinations of Mg, Fe, Co, Ni, Cu, Mn, and Zn cations, systematically investigating the average and local atomic structures, chemical short-range order, magnetic spin configurations, and magnetic properties. All compositions result in ferrimagnetic average structures with extremely similar local bonding environments; however, the samples display varying degrees of cation inversion and, therefore, differing apparent bulk magnetization. Additionally, first-order reversal curve analysis of the magnetic reversal behavior indicates varying degrees of magnetic ordering and interactions, including potentially local frustration. Finally, reverse Monte Carlo modeling of the spin orientation demonstrates a relationship between the degree of cation inversion and the spin collinearity. Collectively, these observations correlate with differences in synthesis procedures. This work provides a framework for understanding magnetic behavior reported for “high-entropy spinels,” revealing many are likely compositionally complex oxides with differing degrees of chemical short-range order—not meeting the community established criteria for high or medium entropy compounds. Moreover, this work highlights the importance of reporting complete sample processing histories and investigating local to long-range atomic arrangements when evaluating potential entropic mixing effects and assumed property correlations in high entropy materials.

36 MATERIALS SCIENCE↗

A NEW DIAGNOSTIC OF THE RADIAL DENSITY STRUCTURE OF Be DISKS

We analyze the intrinsic polarization of two classical Be stars in the process of losing their circumstellar disks via a Be to normal B star transition originally reported by Wisniewski et al. During each of five polarimetric outbursts which interrupt these disk-loss events, we find that the ratio of the polarization across the Balmer jump (BJ+/BJ-) versus the V-band polarization traces a distinct loop structure as a function of time. Since the polarization change across the Balmer jump is a tracer of the innermost disk density whereas the V-band polarization is a tracer of the total scattering mass of the disk, we suggest that such correlated loop structures in Balmer jump-V-band polarization diagrams (BJV diagrams) provide a unique diagnostic of the radial distribution of mass within Be disks. We use the three-dimensional Monte Carlo radiation transfer code HDUST to reproduce the observed clockwise loops simply by turning 'on/off' the mass decretion from the disk. We speculate that counterclockwise loop structures we observe in BJV diagrams might be caused by the mass decretion rate changing between subsequent 'on/off' sequences. Applying this new diagnostic to a larger sample of Be disk systems will provide insight into the time-dependent nature of each system's stellar decretion rate.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-AB-204-11: Development of a Nuclear Medicine Dosimetry Module for the GPU-Based Monte Carlo Code ARCHER

Purpose: To develop a nuclear medicine dosimetry module for the GPU-based Monte Carlo code ARCHER. Methods: We have developed a nuclear medicine dosimetry module for the fast Monte Carlo code ARCHER. The coupled electron-photon Monte Carlo transport kernel included in ARCHER is built upon the Dose Planning Method code (DPM). The developed module manages the radioactive decay simulation by consecutively tracking several types of radiation on a per disintegration basis using the statistical sampling method. Optimization techniques such as persistent threads and prefetching are studied and implemented. The developed module is verified against the VIDA code, which is based on Geant4 toolkit and has previously been verified against OLINDA/EXM. A voxelized geometry is used in the preliminary test: a sphere made of ICRP soft tissue is surrounded by a box filled with water. Uniform activity distribution of I-131 is assumed in the sphere. Results: The self-absorption dose factors (mGy/MBqs) of the sphere with varying diameters are calculated by ARCHER and VIDA respectively. ARCHER’s result is in agreement with VIDA’s that are obtained from a previous publication. VIDA takes hours of CPU time to finish the computation, while it takes ARCHER 4.31 seconds for the 12.4-cm uniform activity sphere case. For a fairer CPU-GPU comparison, more effort will be made to eliminate the algorithmic differences. Conclusion: The coupled electron-photon Monte Carlo code ARCHER has been extended to radioactive decay simulation for nuclear medicine dosimetry. The developed code exhibits good performance in our preliminary test. The GPU-based Monte Carlo code is developed with grant support from the National Institute of Biomedical Imaging and Bioengineering through an R01 grant (R01EB015478)

60 APPLIED LIFE SCIENCES↗

Determining Physical Parameters of Shielded Uranium using Gamma Spectroscopy and the Differential Evolution Adaptive Metropolis (DREAM) Method

Inverse radiation transport is a well-established method for determining unknown parameters within a system that exhibits particle leakage. Two significant challenges of solving inverse transport problems are (1) to determine multiple unknowns without false convergence on local minima and (2) to be able to quantify uncertainty. It was recently demonstrated that the Differential Evolution Adaptive Metropolis (DREAM) method effectively meets both of these challenges. In Bledsoe's 2014 article, the DREAM method was only applied to numerical test cases in which measured data were simulated using MCNP. This paper provides results of research conducted at Oak Ridge National Laboratory (ORNL) in which DREAM was applied to two-dimensional inverse transport problems using real-world measurements. The DREAM method uses a Markov chain Monte Carlo (MCMC) method to obtain a posterior distribution of unknown parameters. In this application, the posterior distribution is determined by using a uniform prior distribution and a likelihood function. The goal of the inverse problem is to find the regions in which the likelihood function is at or near its maximum. In the traditional MCMC approach, a single Markov chain is employed. In practice, MCMC approaches have a high acceptance rate to solutions that are near the current point of sampling, but they exhibit slow convergence to solutions far from the sampling point. The DREAM algorithm was designed to alleviate this issue by initiating multiple Markov chains and using the differential evolution algorithm to generate trial points for each chain. Solving for the mass of radioactive material within a voluminous source is a challenging problem for gamma-ray spectroscopy. Inverse gamma-ray transport can supply a range of possible material compositions, but reducing the differences between predicted and actual measurements can lead to false results. DREAM is a rapid technique for determining the most likely solution for several unknown parameters in an inverse transport problem. This work applies DREAM to a series of gamma spectroscopy experiments performed at ORNL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimation of beryllium ground state energy by Monte Carlo simulation

Quantum Monte Carlo method represent a powerful and broadly applicable computational tool for finding very accurate solution of the stationary Schrödinger equation for atoms, molecules, solids and a variety of model systems. Using variational Monte Carlo method we have calculated the ground state energy of the Beryllium atom. Our calculation are based on using a modified four parameters trial wave function which leads to good result comparing with the few parameters trial wave functions presented before. Based on random Numbers we can generate a large sample of electron locations to estimate the ground state energy of Beryllium. Our calculation gives good estimation for the ground state energy of the Beryllium atom comparing with the corresponding exact data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A method to acquire CT organ dose map using OSL dosimeters and ATOM anthropomorphic phantoms

Purpose: To present the design and procedure of an experimental method for acquiring densely sampled organ dose map for CT applications, based on optically stimulated luminescence (OSL) dosimeters “nanoDots” and standard ATOM anthropomorphic phantoms; and to provide the results of applying the method—a dose data set with good statistics for the comparison with Monte Carlo simulation result in the future.Methods: A standard ATOM phantom has densely located holes (in 3 × 3 cm or 1.5 × 1.5 cm grids), which are too small (5 mm in diameter) to host many types of dosimeters, including the nanoDots. The authors modified the conventional way in which nanoDots are used, by removing the OSL disks from the holders before inserting them inside a standard ATOM phantom for dose measurements. The authors solved three technical difficulties introduced by this modification: (1) energy dependent dose calibration for raw OSL readings; (2) influence of the brief background exposure of OSL disks to dimmed room light; (3) correct pairing between the dose readings and measurement locations. The authors acquired 100 dose measurements at various positions in the phantom, which was scanned using a clinical chest protocol with both angular and z-axis tube current modulations.Results: Dose calibration was performed according to the beam qualities inside the phantom as determined from an established Monte Carlo model of the scanner. The influence of the brief exposure to dimmed room light was evaluated and deemed negligible. Pairing between the OSL readings and measurement locations was ensured by the experimental design. The organ doses measured for a routine adult chest scan protocol ranged from 9.4 to 18.8 mGy, depending on the composition, location, and surrounding anatomy of the organs. The dose distribution across different slices of the phantom strongly depended on the z-axis mA modulation. In the same slice, doses to the soft tissues other than the spinal cord demonstrated relatively small variations, with the maximum COV around 11.4%. This might be attributed to the angular mA modulation, the placement of the dosimeters, the chest cavity of the scanned region, and the size of the phantom. Doses to the spinal cord were consistently lower than those to other soft tissues.Conclusions: The method is suited for acquiring densely sampled organ dose maps, and can be used for studying dose distributions relevant to subject size, organ location, and clinical CT protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Training data selection for accuracy and transferability of interatomic potentials

Abstract Advances in machine learning (ML) have enabled the development of interatomic potentials that promise the accuracy of first principles methods and the low-cost, parallel efficiency of empirical potentials. However, ML-based potentials struggle to achieve transferability, i.e., provide consistent accuracy across configurations that differ from those used during training. In order to realize the promise of ML-based potentials, systematic and scalable approaches to generate diverse training sets need to be developed. This work creates a diverse training set for tungsten in an automated manner using an entropy optimization approach. Subsequently, multiple polynomial and neural network potentials are trained on the entropy-optimized dataset. A corresponding set of potentials are trained on an expert-curated dataset for tungsten for comparison. The models trained to the entropy-optimized data exhibited superior transferability compared to the expert-curated models. Furthermore, the models trained to the expert-curated set exhibited a significant decrease in performance when evaluated on out-of-sample configurations.

36 MATERIALS SCIENCE↗

13 TeV pp collisions, SM type, PYTHIA8 generator: tev13pp_pythia8_qcd_jz

Filtered QCD multijet events (2->2 process) using antiKT6 filters. PDF: LHAPDF6:NNPDF23_lo_as_0130_qed. The sample was created using the Pythia8 tune Tune:pp = 14, similar to ATLAS. The sample recreates ATLAS JZ1-JZ8 slices (without re-weighting). The cross sections are reported inside the files. Pythia8 corresponds to the ATLAS version used to create such samples.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accelerating Monte Carlo simulations of photon transport in a voxelized geometry using a massively parallel graphics processing unit

Purpose: It is a known fact that Monte Carlo simulations of radiation transport are computationally intensive and may require long computing times. The authors introduce a new paradigm for the acceleration of Monte Carlo simulations: The use of a graphics processing unit (GPU) as the main computing device instead of a central processing unit (CPU). Methods: A GPU-based Monte Carlo code that simulates photon transport in a voxelized geometry with the accurate physics models from PENELOPE has been developed using the CUDA programming model (NVIDIA Corporation, Santa Clara, CA). Results: An outline of the new code and a sample x-ray imaging simulation with an anthropomorphic phantom are presented. A remarkable 27-fold speed up factor was obtained using a GPU compared to a single core CPU. Conclusions: The reported results show that GPUs are currently a good alternative to CPUs for the simulation of radiation transport. Since the performance of GPUs is currently increasing at a faster pace than that of CPUs, the advantages of GPU-based software are likely to be more pronounced in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deep neural network uncertainty quantification for LArTPC reconstruction

We evaluate uncertainty quantification (UQ) methods for deep learning applied to liquid argon time projection chamber (LArTPC) physics analysis tasks. As deep learning applications enter widespread usage among physics data analysis, neural networks with reliable estimates of prediction uncertainty and robust performance against overconfidence and out-of-distribution (OOD) samples are critical for their full deployment in analyzing experimental data. While numerous UQ methods have been tested on simple datasets, performance evaluations for more complex tasks and datasets are scarce. Here we assess the application of selected deep learning UQ methods on the task of particle classification using the PiLArNet monte carlo 3D LArTPC point cloud dataset. We observe that UQ methods not only allow for better rejection of prediction mistakes and OOD detection, but also generally achieve higher overall accuracy across different task settings. We assess the precision of uncertainty quantification using different evaluation metrics, such as distributional separation of prediction entropy across correctly and incorrectly identified samples, receiver operating characteristic curves (ROCs), and expected calibration error from observed empirical accuracy. We conclude that ensembling methods can obtain well calibrated classification probabilities and generally perform better than other existing methods in deep learning UQ literature.

47 OTHER INSTRUMENTATION↗

Uncertainty Quantification in Dynamic Simulations of Large-scale Power System Models using the High-Order Probabilistic Collocation Method on Sparse Grids

This paper proposes a probabilistic collocation method (PCM) to quantify the uncertainties with dynamic simulations in power systems. The appraoch was tested on a single-machine-infinite-bus system and the over 15,000 -bus Western Electricity Coordinating Council (WECC) system. Comparing to classic Monte-Carlo (MC) method, the proposed PCM applies the Smolyak algorithm to reduce the number of simulations that have to be performed. Therefore, the computational cost can be greatly reduced using PCM. The algorithm and procedures are described in the paper. Comparison was made with MC method on the single machine as well as the WECC system. The simulation results shows that using PCM only a small number of sparse grid points need to be sampled even when dealing with systems with a relatively large number of uncertain parameters. PCM is, therefore, computationally more efficient than MC method.

Uncertainty quantification, parameter estimation, ↗

The mechanism of low-k SiOCH film modification by oxygen atoms

The interaction of oxygen atoms with three types of plasma enhanced chemical vapor deposition low-k SiOCH films is studied. The samples were treated by O atoms in the far plasma afterglow conditions in a special experimental system designed for this study. The experimental system allowed avoiding the effect of ions and vacuum ultraviolet (VUV) photons on surface reactions and controlling the oxygen atom concentration over the samples. Fourier-transform infrared spectroscopy, x-ray fluorescence, and atomic force microscopy techniques were used to analyze the changes occurring in low-k films. Monte Carlo model for O atom interaction with low-k material that includes penetration, recombination, and reactions with methyl groups was developed. It is shown that the surface recombination on the pore wall surface determines the profile and penetration depth of O atoms into the films. The reaction of O atoms with methyl groups has lower probability and therefore proceeds in the background mode.

36 MATERIALS SCIENCE↗

Quantum-Inspired Power System Reliability Assessment

To enable an in-depth study of power system operation and planning, the assessment of standard reliability indices is inevitable. The Monte Carlo Simulation (MCS) approach is a broadly used method in replacing the analytical methods in reliability indices assessment. The accuracy of MCS, however, highly depends on the sampling size, and hence, a complicated system with large number of components requires a large sampling size and daunting computational effort. To address this shortcoming, we, in this paper attempt to take advantage of potentials of the quantum computing (QC) for power system reliability assessment by realizing the following contributions: 1) an innovative quantum model designed for reliability assessment; 2) a quantum circuit that achieves the quadratic speed up compared to the classical MCS method; 3) an efficient quantum amplitude estimation (QAE) algorithm to accurately evaluate the reliability indices. The accuracy and efficacy of the quantum reliability method are extensively verified and demonstrated on both radial and mesh distribution systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CV4Quantum

CV4Quantum is a statistical technique for reducing the sampling overhead in probabilistic error cancellation, which is an error mitigation technique used in quantum computing. CV4Quantum is based on the control variates method, which is a Monte Carlo variance reduction technique. This repository contains the code and data associated with a demonstration of CV4Quantum using simulation experiments.

Shyamsundar, Prasanth [Fermi National Accelerator ↗

Deep Neural Network Informed Markov Chain Monte Carlo Methods

In subsurface flow modeling, quantifying the uncertainty of model parameters and the corresponding uncertainly on output quantities is a crucial task for groundwater management. Markov chain Monte Carlo (MCMC) methods can take advantage of observed data to estimate parameters in a Bayesian setting. However, MCMC can be slow to converge and produce highly correlated samples when the dimensions of the parameters is high. Using gradients for the posterior distribution can help samplers explore the parameter space more efficiently, but obtaining gradients can be computationally challenging.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗