Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROGRIDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Establishing Regulatory Jurisdictional Boundaries at Collocated Advanced-Reactor Facilities

This white paper discusses establishing and applying nuclear facility jurisdictional boundaries at advanced-nuclear-reactor facilities. It was written for industry review and evaluation with possible consideration by the U.S. Nuclear Regulatory Commission (NRC) for subsequent regulatory action. The paper proposes a regulatory basis for establishing jurisdictional boundaries at operational advanced (i.e., non-light water) reactor installations at sites proximate to and sharing systems with non-NRC regulated facilities (e.g., users of process heat, fossil-plant retrofits, microgrid electrical power, desalination, etc.). Advanced-reactor technologies can be applied to support many industrial applications to replace the burning of fossil fuels as well as produce steam for electricity. The principal application of the current light-water reactor fleet is electricity generation. These varied industrial applications may involve an advanced-reactor design in combination with different site-specific energy-conversion systems. Some of these process-heat applications will require process-heat delivery systems to lie partially outside the advanced-reactor operator’s facility. Energy conversion systems are conventional, non-nuclear equipment and buildings. Given these varied applications, there should be a clear understanding between the advanced-reactor applicant and the NRC regarding a nominal demarcation between those systems that reside within the nuclear facility under the regulatory jurisdiction of the NRC (i.e., within the scope of a 10 Code of Federal Regulations (CFR) 50 operating license or Part 52 design certification and a combined license) and those that fall outside the scope of the NRC (e.g., an industrial facility). Additionally, it is important to have a clear understanding regarding the plant scope that should be addressed in an advanced-reactor facility Part 52, design certification application and the part of the plant scope that could be addressed as part of a site specific combined license application.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids: Preprint

Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

DER Planning with Resilience Analysis Using REopt Lite: A Behind-the-Meter Techno-Economic Analysis Tool

REopt Lite is a techno-economic decision support model for behind-the-meter energy systems design and dispatch modeling. REopt Lite is used to optimize energy systems for buildings, campuses, communities, and microgrids. It is based on a Mixed Integer Linear Programming (MILP) optimization model. It is a fully automated and streamlined energy modeling tool that can be used off-the-shelf for a wide variety of distributed generation integration analyses and at the same time is architected to be extensible for user-specific customizations for advanced users and subject matter experts. It is publicly available as a webtool as well as has an Application Programming Interface (API). The API functionality enables programmatic access to the model facilitating smooth integration with other distribution systems modeling tools, and automated multiple scenarios/sensitivity studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct-DC Power in Buildings: Identifying the Best Applications Today for Tomorrow’s Building Sector

Driven by the increased use of direct current (DC) sources (photovoltaics, battery storage) and DC end-use devices (electronics, solid-state lighting, efficient motors), DC power distribution in buildings and DC microgrids have been proposed as a way to achieve greater efficiency, cost savings, and resiliency in a transitioning building sector. Despite these important benefits, several market and technological barriers inhibit the development of DC distribution, and the market for DC in buildings is still largely in the demonstration phase. Therefore, to jumpstart this technology, a clear path forward must emerge at this early stage of deployment. The goal of this paper is to define specific end-use cases for which DC distribution in buildings is a value proposition today by defining clear efficiency and resiliency benefits while addressing barriers to implementation. The paper begins with a technology and market assessment of DC distribution equipment, end uses, and technology standards. That is followed by results from an expert elicitation of DC power and building end-use professionals (e.g., electrical designers, building operators, engineers) and reports on-site visits and lessons learned from successful (and less successful) field deployments of DC distribution projects in North America. We present specific adoption pathways at the community and building level that can be implemented today, and evaluate them using qualitative and quantitative metrics, such as technology and market readiness, energy savings, and resiliency.

building-level electrical distribution↗

A Community Energy Operations and Planning System: Concept, Use cases, Metrics, and Benefits

Community and city leaders are interested in achieving sustainability goals, providing resilient energy infrastructure, and improving economic competitiveness. Community-level data acquisition and analysis can provide energy and associated benefits that are not possible at the single building level. However, there is a lack of organizational structure, common semantic data models, interoperable systems, and methods to support data-driven decision-making for community-scale energy supply and demand systems. We explored the need and opportunity for a Community Energy Operations and Planning System (Community EOPS), a potential data exchange platform. We conducted “customer discovery” interviews, and reviewed literature, public tools, and technology platforms to identify key energy data “users” and use cases in communities. The key users of the Community EOPS could be developers of mixed-use districts, corporate, defense and university campus energy managers, and city managers of cities that own their energy utility. The value could be for community planning and reporting (for energy data-integrated land use planning and community infrastructure investments in microgrids, storage, district heating and cooling), energy efficiency (leveraging optimizations for community scale energy supply and demand), flexible load management (grid-edge load management to offset, shift, and flatten loads for multiple buildings and EV fleets), cost savings and revenue generation (participating in grid services), and social benefits such as energy resilience, equity, and awareness. We developed a conceptual Community EOPS architecture with recommendations for streamlined and prioritized data acquisition, sharing, and integration driven by prioritized use cases, common metrics, and actionable visualizations that can provide value to a community’s users.

Singh, Reshma↗

Large-Scale Adoption of Self-Synchronized Universal Droop Controller-Based Inverters to Enable Ancillary Services for Different Modes of Distribution System Operations

This work proposes the large-scale adoption of self-synchronized universal droop controller (SUDC)-based inverters to enable ancillary services for different modes of distribution system operations. The IEEE 123 bus system was modeled on a real-time simulator to study the performance of large-scale adoption of SUDC inverters in a distribution system. The resulting data collected shows that the voltage and the frequency were regulated within ranges, such as less than 5% for voltage and less than 0.5% for frequency, under different load variations and grid operations. Also, the black start was achieved within 0.4 s without any voltage overshoot. Through the simulation and validation on a small microgrid and the IEEE 123 bus distribution system, it can be concluded that the SUDC was successfully adopted to regulate the voltage and the frequency within the given ranges, and black start achieved within 1 s without voltage overshoot for different modes of distribution system operations.

14 SOLAR ENERGY↗

Grid stabilization using adjusted voltage regulator response to grid characteristics

Apparatus and methods are disclosed for control systems for improving stability of electrical grids by temporarily reducing voltage output of electrical generators responsive to transient events on an electrical grid. In one example of the disclosed technology, a controller is coupled is to an automatic voltage regulator, which in turn adjusts excitation current of an electrical generator responsive to changes in frequency detected for the electrical grid. Reducing the output voltage temporarily allows for smaller generators to provide power to the microgrid. Methods for selecting parameters determining how the controller generates a regulation signal used to adjust the excitation current are further disclosed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic-Phasor Model of Transformer Inrush Simulation for Unbalanced Distribution System

Abstract— Power system stability is a critical concern, with respect to the increasing distributed energy resources, microgrids, and emphasis on enhancing resiliency. For stability analysis and evaluation, modeling and simulation capabilities are important. In this paper, the authors’ previous work on modeling transformer inrush dynamics is improved with a new formulation of the key equation that converts the dynamic-phasor into real-time value. Simulation results in an electromechanical time-scale are compared with PSCAD results in an electromagnetic time-scale to demonstrate the improvement. The impact of simulation step size is discussed. A bug in PSCAD transformer setting that leads to incorrect magnetizing flux and current under Delta winding type is identified and reported. In addition, explanations and analysis are provided on two modeling techniques utilized since the previous work. This work is being incorporated into the next release of GridLAB-D. The improved transformer inrush calculation enables more accurate predictions of current amplitudes for analyzing the dynamics of distribution operation and control.

power transformers, power system simulation, satur↗

Enabling Interoperability on PV Inverters Using IEC 61850

Inverter based distributed energy resources are integrated into distribution system at a fast pace. Distribution management systems, microgrid controllers, and other distributed assets need to communicate with each other for sensing and control of the different assets. Interoperability is critical to the ease of data exchange between different assets. This presentation will provide a background on interoperability and a laboratory implementation using IEC 61850. Specifically, this presentation will discuss the use of IEC 61850 7-420 to enable interoperability in PV inverter.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Modeling and Simulation of Inrush Currents in Harmonic Domain

Modeling and simulation capabilities are critical to the stability analysis and evaluation of power distribution systems, with respect to the emphasis on resiliency, microgrids, and distributed energy resources. In this paper, a computational method in the harmonic domain is proposed for the periodic steady-state analysis of the nonlinear inrush current phenomenon. The efficient inrush calculation facilitates the predictions of current amplitudes for the power system operation and control. To demonstrate the accuracy and efficiency, simulation results in the harmonic domain are compared with results from PSCAD in an electromagnetic timescale, as well as the authors’ previous works in the frequency-domain. Impacts of the settings of both offset flux and interested harmonic order are discussed. In addition, within the proposed harmonic-domain method, a general approach that utilizes the discrete Fourier transform to obtain the response of a nonlinear device from a stimulus represented in the frequency-domain is utilized. This method can also be extended to perform the transient analysis in future, using trapezoidal rule for the integration.

Xie, Jing↗

Direct-DC Power in Buildings: Identifying the Best Applications Today for Tomorrow’s Building Sector

Driven by the increased use of direct current (DC) sources (photovoltaics, battery storage) and DC end-use devices (electronics, solid-state lighting, efficient motors), DC power distribution in buildings and DC microgrids have been proposed as a way to achieve greater efficiency, cost savings, and resiliency in a transitioning building sector.Despite these important benefits, several market and technological barriers inhibit the development of DC distribution, and the market for DC in buildings is still largely in the demonstration phase. Therefore, to jumpstart this technology, a clear path forward must emerge at this early stage of deployment. The goal of this paper is to define specific end-use cases for which DC distribution in buildings is a value proposition today by defining clear efficiency and resiliency benefits while addressing barriers to implementation.The paper begins with a technology and market assessment of DC distribution equipment, end uses, and technology standards. That is followed by results from an expert elicitation of DC power and building end-use professionals (e.g., electrical designers, building operators, engineers) and reports on-site visits and lessons learned from successful (and less successful) field deployments of DC distribution projects in North America. We present specific adoption pathways at the community and building level that can be implemented today, and evaluate them using qualitative and quantitative metrics, such as technology and market readiness, energy savings, and resiliency.

Vossos, Evangelos↗

EVALUATING FACILITY ENERGY EFFICIENCY AND RESILIENCE OPPORTUNITIES WITH FEDS AND MCOR

Energy resilience has become increasingly important for critical building infrastructure, in response to concerns over potential disruptions to the electrical grid from threats both natural and man-made. Energy efficiency can provide a valuable resource for reducing critical loads and therefore lowering the cost of supplying alternative power. This paper highlights two tools that are well-suited for analyzing building energy efficiency and resilience opportunities and presents a case study for their combined application. The Facility Energy Decision System (FEDS) and Microgrid Component Optimization for Resilience (MCOR) tools can be used together to simulate building systems, identify energy efficiency measures, and evaluate resilience options for powering a site during an outage.

FEDS, MCOR, Energy Efficiency, Resilience, Simulat↗

Review of Graphite Properties Relevant to Micro-Reactor Design

Microreactors are advanced reactors that are designed to be small, scalable, and portable with up to 20 MW power. These reactors could operate independently, or as part of a microgrid, without need of a frequent refueling. Micro-reactors are designed to be deployable to provide electric power in remote locations, therefore providing greater flexibility. Several micro-reactors are under development in the US. These reactors are based on advanced gas-cooled or heat-pipe concepts. While Graphite can be found in various applications, some high-temperature reactors plan to employ Graphite in their core components due to its role as a moderator and its ability to maintain its structural integrity when subjected to elevated temperatures and high neutron fluence. Although there is significant experience with use of Graphite in nuclear applications, there are still unknowns that should be addressed. Graphite properties depend on the graphite type and affected by the fabrication procedures. Material properties are functions of the temperature and irradiation dose. The fundamental properties also affected by the oxidation environment. Therefore, in-depth understanding of graphite properties, including the effect of irradiation, oxidation and other influencing parameters are required to evaluate the design accurately. This draft aims to provide a comprehensive review of material properties for Graphite relevant to micro reactor design. For this work, two distinct grades of graphite were considered, namely IG-110 and Mersen-2114. Physical, thermal, and mechanical properties for these grades were comparatively evaluated. The properties that are discussed in this draft aim to serve as a basis for design and safety analysis.

42 ENGINEERING↗

Guided Resilience Self Assessment Application

Reliable electricity access is vital for everything from hospitals to national security. When grid disturbances occur, it is crucial to minimize the amount of time it takes to recover. Grid resiliency considers both the preparation for and recovery from high-impact low-frequency disturbances (HILF) such as weather events and cyber attacks. The Department of Energy (DOE) Wind Energy Technologies Office (WETO) funds the multi-laboratory Microgrids, Infrastructure Resilience, and Advanced Control Launchpad (MIRACL) project to investigate technologies to support and grow distributed wind. Researchers at Idaho National Laboratory (INL) contribute to resilience and cybersecurity efforts for the project, and have produced a resilience framework to evaluate system resilience based on individual system specifications. In order to make this framework easy for anyone to apply, I have coded a web application that allows users to input their power system qualities, goals, and perceived risks and then receive suggestions on how to improve their grid resiliency. The web application follows the seven steps in the planning stage of the framework process, allowing the user to input information about their grid and select from common goals, metrics, and hazards, as well as add their own. The application currently provides information about how to complete each step, requiring minimal prior knowledge of the framework. Future work for this application will include allowing the user to submit line drawings of their system and incorporate modeling tools so that the hazard simulations of applying the framework is completed for the user.

97 MATHEMATICS AND COMPUTING↗

SIW21-95: Hybridizing Synchronous Condensers with Grid-Forming Battery Energy Storage Systems

One of the main challenges associated with deployment of high shares of inverter-based resources (IBRs) in power grid is not only reduced system inertia but also degrading system strength that may cause severe stability impacts. A minimum level of system strength is needed for the power system to remain stable under normal conditions and to return to a steady state condition following a system disturbance. Significant system strength reduction is expected in almost all planned areas for solar and wind generation deployment. Synchronous condensers (SC) have been considered as one main technology to address the system strength issues for the areas with high levels of IBRs. SCs can help improving reliability and resiliency of power system but they do not provide the full range of services needed by power systems for reliable and economic integration of high shares of inverter-coupled variable generation such as PV generation. Services related to active power controls cannot be provided by SCs due to lack of prime mover. Even for provision of reactive power SCs have certain constraints based on their thermal and stability limits. NREL has been conducting research on a hybridized concept that combines SCs with grid forming (GFM) battery energy storage systems (BESS). This super flexible AC transmission system (SuperFACTS) that combines these two technologies in a single plant under the same controller offers a unique scalable set of services to the power system at all levels (transmission, sub-transmission, distribution, islands and isolated microgrids). Depending on use cases, SuperFACTS can be controlled to provide fully dispatchable and flexible operation using energy storage component, provide a full range of existing and future ancillary and reliability services to the grid (similar or better than conventional sources), maintain adequate levels of grid strength and inertia, and provide fault current for proper operation of protection systems. Therefore, this economic and easy to commercialize solution has potential for significant impacts on certain segments of global energy sector. All types of gird services (market based, reliability and resiliency) can be provided by SuperFACTS plants. GFM BESS can act as a self-black start source for each SuperFACTS module, which in turn can act a black start resource for co-located PV and wind power plants, segments of transmission and distribution networks, for conventional power plants, etc. The issue of in-rush currents during black start is addressed by overcurrent capability of SCs. In this paper we describe the results of modeling for SuperFACTS concept.

grid forming↗

Optimal Sizing of Resilience Solutions for the U.S. Army Reserve

Power or water outages in buildings threaten the ability of the military to support surrounding communities during natural disasters. Outages can last for days, weeks or months. Typical solutions include very expensive batteries and onsite generation that are sized based on historical power needs. The U.S. Army Reserve (USAR) has teamed up with the Pacific Northwest National Laboratory (PNNL) to develop a simulation framework that optimizes future power needs to reduce the cost of resilience solutions. The approach starts with the building. Power needs during an emergency event are simulated at the building end-use level, then loads are reduced through the selection of life cycle cost-effective building-level technology improvements. These new optimized loads are then fed into a microgrid sizing tool that dynamically constructs many different combinations of solar photovoltaic, battery storage, and generator resources to meet the load for hundreds of statistically generated outage scenarios. Six site assessments completed by USAR and PNNL in 2019 have resulted in a 1-14% reduction in overall investment when optimizing the buildings first before determining the generation requirements. This approach helps the Army secure critical missions and provide a 14 day-minimum supply of necessary energy and water in the most efficient manner.

buidlings, efficiency, resilience, FEDS, MCOR↗

Optimizing DER Deployment for Climate, Health, Resilience, and Energy Bill Benefits Using the REopt Model

Climate change, public health, and resilience to power outages are of critical concern to local governments, federal agencies, and the private sector, and are increasingly motivating investments in distributed energy resources (DERs). However, designing a solar-plus-storage system to co-optimize for climate, health, resilience, and energy bill benefits requires complex trade-offs. To address this need, the National Renewable Energy Laboratory has integrated climate and health impacts of grid-purchased electricity and on-site fuel consumption into the publicly-available REopt web tool and API - a techno-economic model that determines the cost-optimal DER system sizes and dispatch strategy. This presentation will provide an overview of the tool's methodology, datasets, and capabilities, including costing emissions into system sizing and dispatch and setting emissions reductions targets. Results of previous work will demonstrate the use of new emissions accounting capabilities by quantifying the impact of including climate and health costs on the optimal resilient microgrid configurations for a hospital, school, and warehouse across 14 U.S. cities.

climate↗

Adaptive protection opportunities, gap assessments, and designs

This report provides a comprehensive overview of adaptive protection schemes in use by distribution systems for protection, switching and control on their systems. A significant focus is placed on how existing schemes can be impacted by increasing penetrations of DER as well as how these schemes can enable DER penetrations to increase. EPRI have conducted a survey of member utilities and performed a comprehensive literature review with the goal of baselining the research and identifying gaps with a focus on the issues that were encountered with adaptive protection on real systems. The five adaptive protection applications that are most prevalent on systems today are discussed in detail. These are weather-based fuse-saving, adaptive protection to reduce short-circuit current, adaptive protection for DER, adaptive protection for microgrids, and distribution automation. A broad overview of the technology is given for each scheme. Issues that have been encountered by utilities are highlighted and the safety and reliability impacts are also examined. As distribution systems, intelligent electronic devices, grid equipment and distribution management systems are rapidly evolving, adaptive protection techniques and technologies will become more widely adopted. This report proposes a framework for a conceptual automatic adaptive protection system. EPRI have ongoing research, development and demonstration projects in all of the constituent elements, however challenges remain to link the elements together in a secure and reliable way. EPRI will continue research into automated adaptive protection applications and challenges for the systems of today and future applications to assist system operators in managing the evolving system.

14 SOLAR ENERGY↗