Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Subarcsecond imaging of the NGC 6334 I(N) protocluster: Two dozen compact sources and a massive disk candidate

Using the Submillimeter Array (SMA) and Karl G. Jansky Very Large Array, we have imaged the massive protocluster NGC 6334 I(N) at high angular resolution (0.''5 ∼ 650 AU) from 6 cm to 0.87 mm, detecting 18 new compact continuum sources. Three of the new sources are coincident with previously identified H{sub 2}O masers. Together with the previously known sources, these data bring the number of likely protocluster members to 25 for a protostellar density of ∼700 pc{sup –3}. Our preliminary measurement of the Q-parameter of the minimum spanning tree is 0.82—close to the value for a uniform volume distribution. All of the (nine) sources with detections at multiple frequencies have spectral energy distributions consistent with dust emission, and two (SMA 1b and SMA 4) also have long wavelength emission consistent with a central hypercompact H II region. Thermal spectral line emission, including CH{sub 3}CN, is detected in six sources: LTE model fitting of CH{sub 3}CN (J = 12-11) yields temperatures of 72-373 K, confirming the presence of multiple hot cores. The fitted LSR velocities range from –3.3 to –7.0 km s{sup –1}, with an unbiased mean square deviation of 2.05 km s{sup –1}, implying a protocluster dynamical mass of 410 ± 260 M {sub ☉}. From analysis of a wide range of hot core molecules, the kinematics of SMA 1b are consistent with a rotating, infalling Keplerian disk of diameter 800 AU and enclosed mass of 10-30 M {sub ☉} that is perpendicular (within 1°) to the large-scale bipolar outflow axis. A companion to SMA 1b at a projected separation of 0.''45 (590 AU; SMA 1d), which shows no evidence of spectral line emission, is also confirmed. Finally, we detect one 218.4400 GHz and several 229.7588 GHz Class-I CH{sub 3}OH masers.

79 ASTRONOMY AND ASTROPHYSICS↗

A high angular resolution survey of massive stars in Cygnus OB2: Results from the Hubble space telescope fine guidance sensors

We present results of a high angular resolution survey of massive OB stars in the Cygnus OB2 association that we conducted with the fine guidance sensor 1R (FGS1r) on the Hubble Space Telescope. FGS1r is able to resolve binary systems with a magnitude difference ΔV < 4 down to separations as small as 0.''01. The sample includes 58 of the brighter members of Cyg OB2, one of the closest examples of an environment containing a large number of very young and massive stars. We resolved binary companions for 12 targets and confirmed the triple nature of one other target, and we offer evidence of marginally resolved companions for two additional stars. We confirm the binary nature of 11 of these systems from complementary adaptive optics imaging observations. The overall binary frequency in our study is 22% to 26% corresponding to orbital periods ranging from 20 to 20,000 yr. When combined with the known short-period spectroscopic binaries, the results support the hypothesis that the binary fraction among massive stars is >60%. One of the new discoveries is a companion to the hypergiant star MT 304 = Cyg OB2-12, and future measurements of orbital motion should provide mass estimates for this very luminous star.

79 ASTRONOMY AND ASTROPHYSICS↗

INTERMEDIATE RESOLUTION NEAR-INFRARED SPECTROSCOPY OF 36 LATE M DWARFS

We present observations of 36 late M dwarfs obtained with the Keck II/NIRSPEC in the J band at a resolution of {approx}20,000. We have measured projected rotational velocities, absolute radial velocities, and pseudo-equivalent widths of atomic lines. Twelve of our targets did not have previous measurements in the literature. For the other 24 targets, we confirm previously reported measurements. We find that 13 stars from our sample have v sin i below our measurement threshold (12 km s{sup -1}) whereas four of our targets are fast rotators (v sin i > 30 km s{sup -1}). As fast rotation causes spectral features to be washed out, stars with low projected rotational velocities are sought for radial velocity surveys. At our intermediate spectral resolution, we have confirmed the identification of neutral atomic lines reported in McLean et al. We also calculated pseudo-equivalent widths of 12 atomic lines. Our results confirm that the pseudo-equivalent width of K I lines is strongly dependent on spectral types. We observe that the pseudo-equivalent width of Fe I and Mn I lines remains fairly constant with later spectral type. We suggest that these lines are particularly suitable for deriving metallicities for late M dwarfs.

79 ASTRONOMY AND ASTROPHYSICS↗

A novel cell weighing method based on the minimum immobilization pressure for biological applications

A novel weighing method for cells with spherical and other regular shapes is proposed in this paper. In this method, the relationship between the cell mass and the minimum aspiration pressure to immobilize the cell (referred to as minimum immobilization pressure) is derived for the first time according to static theory. Based on this relationship, a robotic cell weighing process is established using a traditional micro-injection system. Experimental results on porcine oocytes demonstrate that the proposed method is able to weigh cells at an average speed of 16.3 s/cell and with a success rate of more than 90%. The derived cell mass and density are in accordance with those reported in other published results. The experimental results also demonstrated that this method is able to detect less than 1% variation of the porcine oocyte mass quantitatively. It can be conducted by a pair of traditional micropipettes and a commercial pneumatic micro-injection system, and is expected to perform robotic operation on batch cells. At present, the minimum resolution of the proposed method for measuring the cell mass can be 1.25 × 10{sup −15 }kg. Above advantages make it very appropriate for quantifying the amount of the materials injected into or moved out of the cells in the biological applications, such as nuclear enucleations and embryo microinjections.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vibrationally excited molecular hydrogen near Herschel 36

We present the first high resolution UV spectra toward Herschel 36, a Trapezium-like system of high-mass stars contained within the Lagoon Nebula (M8, NGC 6523). The spectra reveal extreme rovibrational excitation of molecular hydrogen in material at a single velocity or very small range of velocities, with this component presumably lying near the star system and undergoing fluorescent excitation. The overall H{sub 2} excitation is similar to, but apparently larger than, that seen toward HD 37903 which previously showed the largest vibrationally excited H{sub 2} column densities seen in UV absorption spectra. While the velocities of the highly excited H{sub 2} lines are consistent within each observation, it appears that they underwent a ∼60 km s{sup –1} redshift during the 3.6 yr between observations. In neither case does the velocity of the highly excited material match the velocity of the bulk of the line-of-sight material which appears to mostly be in the foreground of M8. Recent work shows unusually excited CH and CH{sup +} lines and several unusually broad diffuse interstellar bands toward Herschel 36. Along with the H{sub 2} excitation, all of these findings appear to be related to the extreme environment within ∼0.1 pc of the massive young stellar system.

79 ASTRONOMY AND ASTROPHYSICS↗

SUBARU/HDS STUDY OF HE 1015-2050: SPECTRAL EVIDENCE OF R CORONAE BOREALIS LIGHT DECLINE

Hydrogen deficiency and a sudden optical light decline of about 6-8 mag are two principal characteristics of R Coronae Borealis (RCB) stars. The high latitude carbon star HE 1015-2050 was identified as a hydrogen-deficient carbon star from low-resolution spectroscopy. Photometric data of the Catalina Real-Time Transient Survey gathered between 2006 February and 2012 May indicate that the object exhibits no variability. However, a high-resolution (R {approx} 50, 000) optical spectrum of this object obtained with the 8.2 m Subaru telescope using High Dispersion Spectrograph on the 2012 January 13 offers sufficient spectral evidence that the object is a cool HdC star of RCB type undergoing light decline. In contrast to the Na I D broad absorption features seen in the low-resolution spectra on several occasions, the high-resolution spectrum exhibits Na I D{sub 2} and D{sub 1} features in emission. A few emission lines due to Mg I, Sc II, Ti I, Ti II, Fe II, and Ba I are also observed in the spectrum of this object for the first time. Such emission features combined with neutral and singly ionized lines of Ca, Ti, Fe, etc., in absorption are reportedly seen in RCBs spectra in the early stage of decline or during the recovery to maximum. Further, the light decline of RCBs is ascribed to the formation of a cloud of soot that obscures the visible photosphere. The presence of such circumstellar material is evident from the polarimetric observations with an estimated V-band percentage polarization of {approx}1.7% for this object.

79 ASTRONOMY AND ASTROPHYSICS↗

Low angular momentum in clumpy, turbulent disk galaxies

We measure the stellar specific angular momentum j{sub s}=J{sub s}/M{sub s} in four nearby (z ≈ 0.1) disk galaxies that have stellar masses M{sub s} near the break M{sub s}{sup ∗} of the galaxy mass function but look like typical star-forming disks at z ≈ 2 in terms of their low stability (Q ≈ 1), clumpiness, high ionized gas dispersion (40−50 km s{sup −1}), high molecular gas fraction (20%–30%), and rapid star formation (∼20M{sub ⊙} yr{sup −1}). Combining high-resolution (Keck-OSIRIS) and large-radius (Gemini-GMOS) spectroscopic maps, only available at low z, we discover that these targets have ∼3 times less stellar angular momentum than typical local spiral galaxies of equal stellar mass and bulge fraction. Theoretical considerations show that this deficiency in angular momentum is the main cause of their low stability, while the high gas fraction plays a complementary role. Interestingly, the low j{sub s} values of our targets are similar to those expected in the M{sub s}{sup ∗} population at higher z from the approximate theoretical scaling j{sub s}∝(1+z){sup −1/2} at fixed M{sub s}. This suggests that a change in angular momentum, driven by cosmic expansion, is the main cause for the remarkable difference between clumpy M{sub s}{sup ∗} disks at high z (which likely evolve into early-type galaxies) and mass-matched local spirals.

79 ASTRONOMY AND ASTROPHYSICS↗

Carbon-enhanced metal-poor stars: CEMP-s and CEMP-no subclasses in the halo system of the Milky Way

We explore the kinematics and orbital properties of a sample of 323 very metal-poor stars in the halo system of the Milky Way, selected from the high-resolution spectroscopic follow-up studies of Aoki et al. and Yong et al. The combined sample contains a significant fraction of carbon-enhanced metal-poor (CEMP) stars (22% or 29%, depending on whether a strict or relaxed criterion is applied for this definition). Barium abundances (or upper limits) are available for the great majority of the CEMP stars, allowing for their separation into the CEMP-s and CEMP-no subclasses. A new method to assign membership to the inner- and outer-halo populations of the Milky Way is developed, making use of the integrals of motion, and applied to determine the relative fractions of CEMP stars in these two subclasses for each halo component. Although limited by small-number statistics, the data suggest that the inner halo of the Milky Way exhibits a somewhat higher relative number of CEMP-s stars than CEMP-no stars (57% versus 43%), while the outer halo possesses a clearly higher fraction of CEMP-no stars than CEMP-s stars (70% versus 30%). Although larger samples of CEMP stars with known Ba abundances are required, this result suggests that the dominant progenitors of CEMP stars in the two halo components were different; massive stars for the outer halo, and intermediate-mass stars in the case of the inner halo.

79 ASTRONOMY AND ASTROPHYSICS↗

Anomalies of the fissile mass control inside a controlled geometry leading to important safety issues - 14298

This article focuses on the very usual case of the fissile mass control inside a controlled geometry, whatever the fissile density in the fissile-moderator mixture is. Although this case is very usual (maximal loading of fissile material in a transport cask, maximal fissile content in a 'geometrically favorable' tank, etc.), some unexpected behaviors ('anomalies') may be met, leading to important nuclear criticality safety issues. This article will show the three following anomalies and the associated safety issues: - the 'non-smooth' variation of the minimum critical mass for a small variation of the geometry size (a cylinder case is considered throughout this article), - the very important differences in critical values, for intermediate-size geometries, between two fissile media having very close minimum critical masses and dimensions, - the change in the hierarchy of different fissile media when the size of the geometry changes. The next part of the article will demonstrate that these anomalies are, from a physics point of view, due to the nature of the fissile material and, from a methodology point of view, due to the fact that this 'Mass- Geometry Control' problem is generally solved without looking at the critical mass for the whole range of geometries. The latter happens because this whole resolution is not trivial and requires either a lot of calculations or human effort to estimate the mass limits as a function of the geometry. Another article will discuss this question of the 'whole' resolution of the problem. (authors)

42 ENGINEERING↗

Confirmation of a steep luminosity function for Lyα emitters at z = 5.7: A major component of reionization

We report the first direct and robust measurement of the faint-end slope of the Lyα emitter (LAE) luminosity function (LF) at z = 5.7. Candidate LAEs from a low-spectral-resolution blind search with IMACS on Magellan-Baade were targeted at higher resolution to distinguish high-redshift LAEs from foreground galaxies. All but 2 of our 42 single-emission-line systems have flux F<2.0×10{sup −17} ergs s{sup −1} cm{sup −2}, making these the faintest emission-lines observed for a z = 5.7 sample with known completeness, an essential property for determining the faint end slope of the LAE LF. We find 13 LAEs as compared to 29 foreground galaxies, in very good agreement with the modeled foreground counts predicted in Dressler et al. that had been used to estimate a faint-end slope of α = −2.0 for the LAE LF. A 32% LAE fraction, LAE/(LAE+foreground) within the flux interval F=2−20 × 10{sup −18} ergs s{sup −1} cm{sup −2} constrains the faint end slope of the LF to −2.35<α<−1.95 (1σ). We show how this steep LF should provide, to the limit of our observations, M{sub UV} ∼ −16, more than 20% of the flux necessary to maintain ionization at z = 5.7, with a factor of 10 extrapolation in flux reaching more than 50%. This is in addition to the comparable contribution by brighter Lyman Break Galaxies M{sub UV} ≲ −18. We suggest that this bodes well for a sufficient supply of Lyman continuum photons by similar, low-mass star-forming galaxies within the reionization epoch at z≈7, only 250 Myr earlier.

79 ASTRONOMY AND ASTROPHYSICS↗

Angle performance on optima MDxt

Angle control on medium current implanters is important due to the high angle-sensitivity of typical medium current implants, such as halo implants. On the Optima MDxt, beam-to-wafer angles are controlled in both the horizontal and vertical directions. In the horizontal direction, the beam angle is measured through six narrow slits, and any angle adjustment is made by electrostatically steering the beam, while cross-wafer beam parallelism is adjusted by changing the focus of the electrostatic parallelizing lens (P-lens). In the vertical direction, the beam angle is measured through a high aspect ratio mask, and any angle adjustment is made by slightly tilting the wafer platen prior to implant. A variety of tests were run to measure the accuracy and repeatability of Optima MDxt's angle control. SIMS profiles of a high energy, channeling sensitive condition show both the cross-wafer angle uniformity, along with the small-angle resolution of the system. Angle repeatability was quantified by running a channeling sensitive implant as a regular monitor over a seven month period and measuring the sheet resistance-to-angle sensitivity. Even though crystal cut error was not controlled for in this case, when attributing all Rs variation to angle changes, the overall angle repeatability was measured as 0.16 Degree-Sign (1{sigma}). A separate angle repeatability test involved running a series of V-curves tests over a four month period using low crystal cut wafers selected from the same boule. The results of this test showed the angle repeatability to be <0.1 Degree-Sign (1{sigma}).

43 PARTICLE ACCELERATORS↗

DO NOT FORGET THE FOREST FOR THE TREES: THE STELLAR-MASS HALO-MASS RELATION IN DIFFERENT ENVIRONMENTS

The connection between dark matter halos and galactic baryons is often not well constrained nor well resolved in cosmological hydrodynamical simulations. Thus, halo occupation distribution models that assign galaxies to halos based on halo mass are frequently used to interpret clustering observations, even though it is well known that the assembly history of dark matter halos is related to their clustering. In this paper we use high-resolution hydrodynamical cosmological simulations to compare the halo and stellar mass growth of galaxies in a large-scale overdensity to those in a large-scale underdensity (on scales of about 20 Mpc). The simulation reproduces assembly bias, in which halos have earlier formation times in overdense environments than in underdense regions. We find that the ratio of stellar mass to halo mass is larger in overdense regions in central galaxies residing in halos with masses between 10{sup 11} and 10{sup 12.9} M{sub ⊙}. When we force the local density (within 2 Mpc) at z = 0 to be the same for galaxies in the large-scale over- and underdensities, we find the same results. We posit that this difference can be explained by a combination of earlier formation times, more interactions at early times with neighbors, and more filaments feeding galaxies in overdense regions. This result puts the standard practice of assigning stellar mass to halos based only on their mass, rather than considering their larger environment, into question.

79 ASTRONOMY AND ASTROPHYSICS↗

NEAR-INFRARED H{sub 2} AND CONTINUUM SURVEY OF EXTENDED GREEN OBJECTS

The Spitzer GLIMPSE survey has revealed a number of 'Extended Green Objects' (EGOs) that display extended emission at 4.5 {mu}m. These EGOs are potential candidates for high-mass protostellar outflows. We used high-resolution (<1'') H{sub 2} 1-0 S(1) line, K-, and H-band images from the United Kingdom Infrared Telescope to study 34 EGOs to investigate their nature. We found that 12 EGOs exhibit H{sub 2} outflows (two with chains of H{sub 2} knotty structures, five with extended H{sub 2} bipolar structures, three with extended H{sub 2} lobes, and two with pairs of H{sub 2} knots). Of the 12 EGOs with H{sub 2} outflows, three exhibit similar morphologies between the 4.5 {mu}m and H{sub 2} emission. However, the remaining nine EGOs show that the H{sub 2} features are more extended than the continuum features, and the H{sub 2} emission is seldom associated with continuum emission. Furthermore, the morphologies of the near-infrared continuum and 4.5 {mu}m emission are similar to each other for those EGOs with K-band emission, implying that at least part of the IRAC-band continuum emission of EGOs comes from scattered light from the embedded young stellar objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Elucidating the Gas-Phase Behavior of Nitazene Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry

2-benzylbenzimidazoles, or “nitazenes”, are a class of novel synthetic opioids (NSOs) that are increasingly being detected alongside fentanyl analogs and other opioids in drug overdose cases. Nitazenes can be 20x more potent than fentanyl but are not routinely tested for during postmortem or clinical toxicology drug screens; thus, their prevalence in drug overdose cases may be under-reported. Traditional analytical workflows utilizing liquid chromatography-tandem mass spectrometry (LC-MS/MS) often require additional confirmation with authentic reference standards to identify a novel nitazene. However, additional analytical measurements with ion mobility spectrometry (IMS) may provide a path towards reference-free identification, which would greatly accelerate NSO identification rates in toxicology labs. Presented here are the first IMS and collision cross section (CCS) measurements on a set of fourteen nitazene analogs using a Structures for Lossless Ion Manipulations (SLIM)-Orbitrap MS. All nitazenes exhibited two high intensity baseline-separated IMS distributions, which fentanyls and other drug and drug-like compounds also exhibit. Incorporating water into the electrospray ionization (ESI) solution caused the intensities of the higher mobility IMS distributions to increase the intensities of the lower mobility IMS distributions to decrease. Nitazenes lacking a nitro group at the R1 position exhibited the greatest shifts in signal intensities due to water. Furthermore, IMS-MS/MS experiments showed that the higher mobility IMS distributions of all nitazenes produced fragment ions with m/z 72, 100, and other low intensity fragments while the lower mobility IMS distributions only produced fragment ions with m/z 72 and 100. The IMS, solvent, and fragmentation studies provide experimental evidence that nitazenes potentially exhibit three gas-phase protomers. In conclusion, the cyclic IMS capability of SLIM was also employed to partially resolve four sets of structurally similar nitazene isomers (e.g., protonitazene/isotonitazene, butonitazene/isobutonitazene/secbutonitazene), showcasing the potential of using high-resolution IMS separations in MS-based workflows for reference-free identification of emerging nitazenes and other NSOs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Annotation of Untargeted Metabolomics Data through Buffer Modifications That Shift Adduct Mass and Intensity

Annotation of untargeted high-resolution full-scan LC-MS metabolomics data remains challenging due to individual metabolites generating multiple LC-MS peaks arising from isotopes, adducts and fragments. Adduct annotation is a particular challenge, as the same mass difference between peaks can arise from adduct formation, fragmentation, or different biological species. To address this, here we describe a Buffer Modification Workflow (BMW), in which the same sample is run by LC-MS in both liquid chromatography solvent with 14 NH 3 -acetate buffer, and in solvent with the buffer modified with 15 NH 3 -formate. Buffer switching results in characteristic mass and signal intensity changes for adduct peaks, facilitating their annotation. This relatively simple and convenient chromatography modification annotated yeast metabolomics data with similar effectiveness to growing the yeast in isotope-labeled media. Application to mouse liver data annotated both known metabolite and known adduct peaks with 95% accuracy. Altogether, it identified 26% of ~ 27,000 liver LC-MS features as putative metabolites, of which ~ 2600 showed HMDB or KEGG database formula match. This workflow is well-suited to biological samples that cannot be readily isotope labeled, including plants, mammalian tissues, and tumors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

IRAM 30 m large scale survey of {sup 12}CO(2-1) and {sup 13}CO(2-1) emission in the Orion molecular cloud

Using the IRAM 30 m telescope, we have surveyed a 1 × 0.°8 part of the Orion molecular cloud in the {sup 12}CO and {sup 13}CO (2-1) lines with a maximal spatial resolution of ∼11'' and spectral resolution of ∼0.4 km s{sup –1}. The cloud appears filamentary, clumpy, and with a complex kinematical structure. We derive an estimated mass of the cloud of 7700 M {sub ☉} (half of which is found in regions with visual extinctions A{sub V} below ∼10) and a dynamical age for the nebula of the order of 0.2 Myr. The energy balance suggests that magnetic fields play an important role in supporting the cloud, at large and small scales. According to our analysis, the turbulent kinetic energy in the molecular gas due to outflows is comparable to turbulent kinetic energy resulting from the interaction of the cloud with the H II region. This latter feedback appears negative, i.e., the triggering of star formation by the H II region is inefficient in Orion. The reduced data as well as additional products such as the column density map are made available online (http://userpages.irap.omp.eu/∼oberne/Olivier{sub B}erne/Data).

79 ASTRONOMY AND ASTROPHYSICS↗

Study of Chemical Changes in Uranium Oxyfluoride Particles Progress Report June 2008 - February 2009

The present study aims to demonstrate how knowledge of time-dependent changes in uranium oxyfluoride particles can benefit particle analyses for environmental sampling. Environmental sampling depends upon laboratory analysis of nuclear material that has often been exposed to the environment after it was produced. It is therefore important to understand how those environmental conditions might have changed the chemical composition of the material over time. To investigate this, we prepared a set of uranium oxyfluoride particles at the Institute for Reference Materials and Measurements (IRMM-DG Joint Research Centre of the European Commission, Belgium). These UO{sub 2}F{sub 2} particles were prepared from the release and subsequent hydrolysis of UF{sub 6} gas, and were stored at LLNL in environmental chambers, set to different humidity, temperature and lighting conditions. An experimental plan was drafted to assess the number of analyses required to track the changes in particle composition, morphology, and structure. Due to its high spatial resolution and excellent transmission, the NanoSIMS secondary ion mass spectrometer at LLNL was found to be the optimal tool to measure individual oxyfluoride particles. This was confirmed by our participation in the inter-laboratory measurement campaign for particle analysis (NUSIMEP-6), organized by the IRMM in June last year. The reported uranium isotope ratios demonstrated the precision and accuracy of the NanoSIMS and ims 3f SIMS measurements at LLNL, and provided a high degree of confidence that the new measurements on the UO{sub 2}F{sub 2} samples will be of comparable high quality. As fluorine is known to be a chemically-sensitive compound, we measured the intensity of the fluorine secondary ions relative to the ions generated by the matrix to evaluate the rate of particle degradation under different environmental conditions. A relative sensitivity factor was empirically determined to convert these measurements to absolute fluorine concentrations. Additional measurements in selected uranium compounds were carried out to account for variations in matrix composition. Because of the complexity of both the SIMS instruments, as well as the nature of the samples, we spent a substantial amount of time on instrument training and instrument set up. The latest NanoSIMS measurements on the freshly-prepared UO{sub 2}F{sub 2} particles however, showed that we are on the right track when it comes to determining the chemical changes in individual uranium particles. At PNNL, several optical techniques including cryogenic laser-induced time-resolved U(VI) fluorescence micro-spectroscopy, Raman spectroscopy, and Fourier transform infrared spectroscopy will be applied to investigate molecular transformations of the particles. As a control, dynamic SIMS measurements will also be performed on a subset of the samples sent to PNNL.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A two-color tunable infrared/vacuum ultraviolet spectrometer for high-resolution spectroscopy of molecules in molecular beams

We describe here the key technical elements of a two-color tunable IR/VUV photoionization TOF mass spectrometer system which allows a wide-range of high-resolution experiments to be performed on a diverse range of cold molecules and clusters in a molecular beam. In particular we highlight the methods we have applied to provide efficient wavelength separation of the VUV radiation from the longer wavelength components used to generate it and discuss a number of systems that we have studied with the instrument which highlight its flexibility for use in the study of molecular spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗