Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

X-Ray Polarization Capabilities of a Small Explorer Mission

X-ray polarization measurements hold great promise for studying the geometry and emission mechanisms in the strong gravitational and magnetic fields that surround black holes and neutron stars. In spite of this, the observational situation remains very limited; the last instrument dedicated to X-ray polarimetry flew decades ago on OSO-8, and the few recent measurements have been made by instruments optimized for other purposes. However, the technical capabilities to greatly advance the observational situation are in hand. Recent developments in micro-pattern gas detectors allow use of the polarization sensitivity of the photo-electric effect, which is the dominant interaction in the band above 2 keV. We present the scientific and technical requirements for an X-ray polarization observatory consistent with the scope of a NASA Small Explorer (SMEX) mission, along with a representative catalog of what the observational capabilities and expected sensitivities for the first year of operation could be. The mission is based on the technically robust design of the Gravity and Extreme Magnetism SMEX (GEMS) which completed a Phase B study and Preliminary Design Review in 2012. The GEMS mission is enabled by time projection detectors sensitive to the photo-electric effect. Prototype detectors have been designed, and provide engineering and performance data which support the mission design. The detectors are further characterized by low background, modest spectral resolution, and sub-millisecond timing resolution. The mission also incorporates high efficiency grazing incidence X-ray mirrors, design features that reduce systematic errors (identical telescopes at different azimuthal angles with respect to the look axis, and mounted on a rotating spacecraft platform), and a moderate capability to perform Target of Opportunity observations. The mission operates autonomously in a low earth, low inclination orbit with one to ten downlinks per day and one or more uplinks per week. Data and calibration products will be made available through the High Energy Astrophysics Science and Archival Research Center (HEASARC).

GEMS↗

Broad band simulation of Gamma Ray Bursts (GRB) prompt emission in presence of an external magnetic field

The origin of prompt emission in GRBs is not yet well understood. The simplest and most popular model is Synchrotron Self-Compton (SSC) emission produced by internal shocks inside an ultra-relativistic jet. However, recent observations of a delayed high energy component by the Fermi-LAT instrument have encouraged alternative models. Here we use a recently developed formulation of relativistic shocks for GRBs to simulate light curves and spectra of synchrotron and self-Compton emissions in the framework of internal shock model. This model takes into account the evolution of quantities such as densities of colliding shells, and fraction of kinetic energy transferred to electrons and to induced magnetic field. We also extend this formulation by considering the presence of a precessing external magnetic field. These simulations are very realistic and present significant improvement with respect to previous phenomenological GRB simulations. They reproduce light curves of separate peaks of real GRBs and variety of spectral slopes at E > E{sub peak} observed by the Fermi-LAT instrument. The high energy emission can be explained by synchrotron emission and a subdominant contribution from inverse Compton. We also suggest an explanation for extended tail emission and relate it to the screening of the magnetic field and/or trapping of accelerated electrons in the electromagnetic energy structure of the plasma in the shock front. Spectral slopes of simulated bursts at E << E{sub peak} are consistent with theoretical prediction and at E < E{sub peak} can be flatter if the spectrum of electrons is roughly flat or has a shallow slope at low energies. The observed flat spectra at soft gamma-ray and hard x-ray bands is the evidence that there is a significant contribution at E < E{sub peak} from lower Lorentz factor wing of electron distribution which have a roughly random acceleration rather than being thermal. This means that the state of matter in the jet at the time of ejection is most probably nonthermal. As for the effect of a precessing external magnetic field, we show that due to the fast variation of other quantities, its signature in the Power Distribution Spectrum (PDS) is significantly suppressed and only when the duration of the burst is few times longer than the oscillation period it can be detected, otherwise either it is confused with the Poisson noise or with intrinsic variations of the emission. Therefore, low significant oscillations observed in the PDS of GRB 090709a are most probably due to a precessing magnetic field.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining resonant photon-axion conversions in the early universe

The presence of a primordial magnetic field would have induced resonant conversions between photons and axion-like particles (ALPs) during the thermal history of the Universe. These conversions would have distorted the blackbody spectrum of the cosmic microwave background (CMB). In this context, we derive bounds on the photon-ALP resonant conversions using the high precision CMB spectral data collected by the FIRAS instrument on board of the Cosmic Background Explorer. We obtain upper limits on the product of the photon-ALP coupling constant g times the magnetic field strength B down to gB ∼< 10{sup −13} GeV{sup −1} nG for ALP masses below the eV scale.

79 ASTRONOMY AND ASTROPHYSICS↗

First result for the neutrino magnetic moment from measurements with the GEMMA spectrometer

The first result obtained in the measurements of the neutrino magnetic moment at the Kalinin nuclear power plant with the GEMMA spectrometer is presented. A high-purity germanium detector of mass 1.5 kg placed at a distance of 13.9 m from the reactor core is used in the spectrometer. The antineutrino flux at the detector position is 2.73 x 10{sup 13{nu}}-bar/(cm{sup 2} s). The differential method is used to select events of electromagnetic antineutrino-electron scattering. The spectra taken in the reactor-on and reactor-off modes over 6200 and 2064 h, respectively, are compared. On the basis of a data analysis, an upper limit of 5.8 x 10{sup -11} {mu}B was set on the neutrino magnetic moment {mu}{sub {nu}}at a 90% C.L.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of radial location of rotating magnetic islands by use of poloidal soft x-ray detector arrays in the STOR-M tokamak

A technique is presented for determining the radial location of the rotating magnetic islands in the STOR-M tokamak by use of soft x-ray (SXR) detector arrays. The location is determined by examining the difference in the integrated SXR emission intensities through two adjacent lines of sight. A model for calculating dependence of the line integrated SXR emission intensity on the radius, the mode numbers and the magnetic island geometry, has been developed. The SXR difference signal shows phase inversion when the impact parameter of the line of sight sweeps across the magnetic islands. Experimentally, the difference SXR signals significantly reduce noise and suppress the influence of background plasma fluctuations through common mode rejection when a dominant mode exists in the STOR-M tokamak. The radial locations of the m= 2 magnetic islands have been determined under several experimental conditions in the STOR-M discharges. With the decrease in the tokamak discharge current and thus the increase of the safety factor at the edge, the radial location of the m= 2 magnetic islands has been found to move radially inward.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Patterned anvils for high pressure measurements at low temperature

Multiprobe high pressure measurements require electrical leads in the sample chamber. Compared to conventional wire-based techniques, metallic tracks patterned onto the anvil surface improve reliability and ease of use, and enable novel and more demanding measurements under high pressure. We have developed new anvil designs based on sputter-deposited tracks on alumina and moissanite anvils. These anvils allow convenient and reliable measurements of electrical transport properties or of the magnetic susceptibility under hydrostatic conditions, as demonstrated by test measurements on Pb and Ca{sub 3}Ru{sub 2}O{sub 7}.

36 MATERIALS SCIENCE↗

Instrument for in-situ orientation of superconducting thin-film resonators used for electron-spin resonance experiments

When used in electron-spin resonance measurements, superconducting thin-film resonators must be precisely oriented relative to the external magnetic field in order to prevent the trapping of magnetic flux and the associated degradation of resonator performance. We present a compact design solution for this problem that allows in-situ control of the orientation of the resonator at cryogenic temperatures. Tests of the apparatus show that when proper alignment is achieved, there is almost no hysteresis in the field dependence of the resonant frequency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EVIDENCE FOR SHEET-LIKE ELEMENTARY STRUCTURES IN THE SUN'S ATMOSPHERE?

Narrow, thread-like structures in the Sun's chromosphere are currently understood to be plasma guided along narrow tubes of magnetic flux. We report on 1 s cadence imaging spectroscopic measurements of the H{alpha} line with the IBIS Fabry-Perot instrument at the Dunn Solar Telescope, obtained +0.11 nm from line center. Rapid changes grossly exceeding the Alfven speed are commonly seen along the full extent of many chromospheric threads. We argue that only an optical superposition effect can reasonably explain the data, analogous to striations of curtains blowing in the wind. Other explanations appear to require significant contrivances to avoid contradicting various aspects of the data. We infer that the absorbing plasma exists in two-dimensional sheet-like structures within the three-dimensional magnetofluid, related perhaps to magnetic tangential discontinuities. This interpretation demands a re-evaluation of basic assumptions about low-{beta} solar plasmas, as advocated by Parker, with broader implications in astrophysics and plasma physics. Diverse, high-cadence observations are needed to further define the relationship between magnetic field and thermal fine structure.

79 ASTRONOMY AND ASTROPHYSICS↗

Contributed Review: Nuclear magnetic resonance core analysis at 0.3 T

Nuclear magnetic resonance (NMR) provides a powerful toolbox for petrophysical characterization of reservoir core plugs and fluids in the laboratory. Previously, there has been considerable focus on low field magnet technology for well log calibration. Now there is renewed interest in the study of reservoir samples using stronger magnets to complement these standard NMR measurements. Here, the capabilities of an imaging magnet with a field strength of 0.3 T (corresponding to 12.9 MHz for proton) are reviewed in the context of reservoir core analysis. Quantitative estimates of porosity (saturation) and pore size distributions are obtained under favorable conditions (e.g., in carbonates), with the added advantage of multidimensional imaging, detection of lower gyromagnetic ratio nuclei, and short probe recovery times that make the system suitable for shale studies. Intermediate field instruments provide quantitative porosity maps of rock plugs that cannot be obtained using high field medical scanners due to the field-dependent susceptibility contrast in the porous medium. Example data are presented that highlight the potential applications of an intermediate field imaging instrument as a complement to low field instruments in core analysis and for materials science studies in general.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Giotto magnetic field investigation

The Giotto spacecraft will carry sensors for investigating the interplanetary magnetic field while en route and the interaction between the solar wind magnetoplasma and Halley's Comet neutral gas outflow during close approach. Giotto will carry an outboard biaxial fluxgate system and inboard electronics. The instrumentation draws 1.2 kW and weighs 1.31 kg. Sampling rates will be 28/sec during close encounter, covering selectable ranges from 16 nT to 65,535 nT. In-flight calibration techniques are under development to ensure magnetic cleanliness will be obtained. Measurements are also planned of the inbound bow shock, the magnetosheath and the cometary ionopause. The data will be collected as close as 1000 km from the comet surface.

Neubauer, F. M.↗

Inelastic Neutron Scattering Data for Ba₃Zn(Ru₀.₁Sb₁.₉)O₉

This dataset contains inelastic neutron scattering measurements on the magnetically dilute compound Ba₃Zn(Ru₀.₁Sb₁.₉)O₉, collected at the Spallation Neutron Source using the Cold Neutron Chopper Spectrometer (CNCS) and the SEQUOIA Fine-Resolution Fermi Chopper Spectrometer. The sample consists of nominally 5% magnetic Ru⁵⁺ ions (S = 3/2) randomly substituted into a diamagnetic Sb⁵⁺ matrix. Measurements were performed at base temperature (2–5 K) and 300 K using multiple incident energies (1.00, 3.32, 12.0, and 100 meV) to resolve magnetic excitations from isolated monomers and small Ru clusters (dimers, trimers, etc.). The dataset includes raw event-mode files, momentum- and energy-resolved spectra, and supporting metadata for instrument configuration, sample environment, and reduction parameters.

36 MATERIALS SCIENCE↗

Initial ISEE magnetometer results - Shock observation

A selection of early measurements is used to illustrate the three advantages brought by ISEE to the study of natural collisionless shocks. These advantages are the ability to resolve most space/time ambiguity by means of simultaneous two-point measurements, instrumentation to make comprehensive field and particle observations covering all important quantities, and the capacity to record data at high time resolution. Magnetic-field records from shocks of various types are presented; the types of shock include laminar, supercritical, quasi-perpendicular, high-beta, and quasi-parallel. The spacing of the two spacecraft and the resolution of the system are employed to develop numerous kinematic descriptions of the shocks and the waves that compose and surround them. Data from a single particle experiment are correlated with field data for three cases to demonstrate the important role of comprehensive instrumentation.

Russell, C. T.↗

Electron dynamics and acceleration study in a magnetized plasma-filled cylindrical waveguide

In this article, EH{sub 01} field components are evaluated in a cylindrical waveguide filled with plasma in the presence of external static magnetic field applied along the direction of the mode propagation. The electron acceleration inside the plasma-filled cylindrical waveguide is investigated numerically for a single-electron model. It is found that the electron acceleration is very sensitive to the initial phase of mode-field components, external static magnetic field, plasma density, point of injection of the electron, and microwave power density. The maximum amplitude of the EH{sub 01} mode's field components is approximately 100 times greater than the vacuum-waveguide case for operating microwave frequency f=7.64 GHz, plasma density n{sub 0}=1.08x10{sup 17} m{sup -3}, initial phase angle {phi}{sub 0}=60 deg., and microwave power {approx}14 MW in a cylindrical waveguide with a radius of 2.1 cm. An electron with 100 keV gets 27 MeV energy gain in 2.5 cm along the waveguide length in the presence of external power {approx}14 MW with a microwave frequency of 7.64 GHz. The electron trajectory is also analyzed under the effects of magnetic field when the electron is injected in the waveguide at r=R/2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron Dynamics in a Subproton-Gyroscale Magnetic Hole

Magnetic holes are ubiquitous in space plasmas, occurring in the solar wind, downstream of planetary bow shocks, and inside the magnetosphere. Recently, kinetic-scale magnetic holes have been observed near Earth's central plasma sheet. The Fast Plasma Investigation on NASA's Magnetospheric Multiscale (MMS) mission enables measurement of both ions and electrons with 2 orders of magnitude increased temporal resolution over previous magnetospheric instruments. Here we present data from MMS taken in Earth's nightside plasma sheet and use high-resolution particle and magnetometer data to characterize the structure of a subproton-scale magnetic hole. Electrons with gyroradii above the thermal gyroradius but below the current layer thickness carry a current sufficient to account for a 10-20 depression in magnetic field magnitude. These observations suggest that the size and magnetic depth of kinetic-scale magnetic holes is strongly dependent on the background plasma conditions.

Gershman, Daniel J.↗

A study on fast digital discrimination of neutron and gamma-ray for improvement neutron emission profile measurement

Neutron and γ-ray (n-γ) discrimination with a digital signal processing system has been used to measure the neutron emission profile in magnetic confinement fusion devices. However, a sampling rate must be set low to extend the measurement time because the memory storage is limited. Time jitter decreases a discrimination quality due to a low sampling rate. As described in this paper, a new charge comparison method was developed. Furthermore, automatic n-γ discrimination method was examined using a probabilistic approach. Analysis results were investigated using the figure of merit. Results show that the discrimination quality was improved. Automatic discrimination was applied using the EM algorithm and k-means algorithm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarimetry diagnostic on OMEGA EP using a 10-ps, 263-nm probe beam

A polarimetry diagnostic was built and characterized for magnetic-field measurements in laser-plasma experiments on the OMEGA EP laser. This diagnostic was built into the existing 4ω (263-nm) probe system that employs a 10-ps laser pulse collected with an f/4 imaging system. The diagnostic measures the rotation of the probe beam's polarization. The polarimeter uses a Wollaston prism to split the probe beam into orthogonal polarization components. Spatially localized intensity variations between images indicate polarization rotation. Magnetic fields can be calculated by combining the polarimetry data with the measured plasma density profile obtained from angular filter refractometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ELECTRON TRAPPING IN WIGGLER AND QUADRUPOLE MAGNETS OF CESRTA

The Cornell Electron Storage Ring (CESR) has been reconfigured as an ultra low emittance damping ring for use as a test accelerator (CesrTA) for International Linear Collider (ILC) damping ring R&D [1]. One of the primary goals of the CesrTA program is to investigate the interaction of the electron cloud with low emittance positron beam to explore methods to suppress the electron cloud, develop suitable advanced instrumentation required for these experimental studies and benchmark predictions by simulation codes. This paper reports the simulation of the electron-cloud formation in the wiggler and quadrupole magnets using the 3D code CLOUDLAND. We found that electrons can be trapped with long lifetime in a quadrupole magnet due to the mirror field trapping mechanism and photoelectrons produced in the wiggler zero field zone have long lifetime due to their complicated trajectory.

43 PARTICLE ACCELERATORS↗

The fast reciprocating magnetic probe system on the J-TEXT tokamak

The fast reciprocating magnetic probe (FRMP) system is newly developed on the Joint Texas Experimental Tokamak (J-TEXT) to measure the local magnetic fluctuations at the plasma edge. The magnetic probe array in the FRMP consists of four 2-dimensional magnetic probes arranged at different radial locations to detect local poloidal and radial magnetic fields. These probes are protected by a graphite and boron nitride casing to improve the frequency response of each probe; they are mounted on the head of a movable rod, which is oriented along radial direction at the top of the torus. In the experiments, multiple core diagnostics show that the insertion of the FRMP has little impact on the equilibrium of the plasma. Local magnetic fluctuations inside the last closed flux surface are successfully measured by the FRMP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗