Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Ultra-low field nuclear magnetic resonance and magnetic resonance imaging to discriminate and identify materials

An ultra-low magnetic field NMR system can non-invasively examine containers. Database matching techniques can then identify hazardous materials within the containers. Ultra-low field NMR systems are ideal for this purpose because they do not require large powerful magnets and because they can examine materials enclosed in conductive shells such as lead shells. The NMR examination technique can be combined with ultra-low field NMR imaging, where an NMR image is obtained and analyzed to identify target volumes. Spatial sensitivity encoding can also be used to identify target volumes. After the target volumes are identified the NMR measurement technique can be used to identify their contents.

Kraus, Robert H↗

Magnet Technology for Power Converters: Nanocomposite Magnet Technology for High Frequency MW-Scale Power Converters

Solar ADEPT Project: CMU is developing a new nanoscale magnetic material that will reduce the size, weight, and cost of utility-scale PV solar power conversion systems that connect directly to the grid. Power converters are required to turn the energy that solar power systems create into useable energy for the grid. The power conversion systems made with CMU’s nanoscale magnetic material have the potential to be 150 times lighter and significantly smaller than conventional power conversion systems that produce similar amounts of power.

ARPA-E↗

Rotating-frame gradient fields for magnetic resonance imaging and nuclear magnetic resonance in low fields

A system and method for Fourier encoding a nuclear magnetic resonance (NMR) signal is disclosed. A static magnetic field B.sub.0 is provided along a first direction. An NMR signal from the sample is Fourier encoded by applying a rotating-frame gradient field B.sub.G superimposed on the B.sub.0, where the B.sub.G comprises a vector component rotating in a plane perpendicular to the first direction at an angular frequency .omega.in a laboratory frame. The Fourier-encoded NMR signal is detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarimetry-Interferometry Diagnostic for Magnetic Field and Magnetic Fluctuation Measurements in High-Performance and Long-Pulse Tokamaks (Final Report)

In this grant, we executed a multi-year plan to develop an advanced Faraday-effect polarimeter-interferometer system to address both fluctuation and equilibrium diagnostic needs by providing a measurement of the plasma internal magnetic field fluctuations (including non-axisymmetric 3-D perturbations) and plasma vertical position. This diagnostic included both fast time response and low phase noise so that both the temporal dynamics of equilibrium quantities as well as high-frequency electromagnetic fluctuations could be measured simultaneously, adding new and unique measurement capabilities for the core of high-temperature plasmas. The combined polarimeter-interferometer diagnostic development was applied primarily to the tokamak magnetic configuration, focusing on high-performance regimes including H-mode, reversed shear advanced tokamak scenarios, and non-inductive current drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical sensing of magnetic fields using magnetically sensitive materials

The invention provides a method for measuring the magnetic field of an electromagnetic component having the steps of: instrumenting one or more portions of an electromagnetic component by placing an optical fiber in electromagnetic communication with the one or more portions of said electromagnetic component; energizing the electromagnetic component; interrogating the optical fiber using light and an optical detector; and determining changes in the magnetic field incident on the optical fiber based on the detected changes in the light received by the optical detector.

Ohodnicki, Paul↗

Structure and Magnetic Ordering of a 2-D MnII(TCNE)I(OH2) (TCNE = tetracyanoethylene) Organic-based Magnet (Tc = 171 K)

Mn{sup II}(TCNE)I(OH{sub 2}) was isolated from the reaction of tetracyanoethylene (TCNE) and MnI{sub 2}(THF){sub 3}, and has a 2-D structure possessing an unusual, asymmetric bonded {mu}{sub 4}-[TCNE]{sup {sm_bullet}-}. Direct antiferromagnetic coupling between the S = 5/2 Mn{sup II} and S = 1/2 [TCNE]{sup {sm_bullet}-} leads to magnetic ordering as a canted antiferromagnet at a T{sub c} of 171 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Alternating current magnetic susceptibility of a molecular magnet submonolayer directly patterned onto a micro superconducting quantum interference device

We report the controlled integration, via dip pen nanolithography, of monolayer dots of ferritin-based CoO nanoparticles (12 μ{sub B}) into the most sensitive areas of a microSQUID sensor. The nearly optimum flux coupling between these nanomagnets and the microSQUID improves the achievable sensitivity by a factor 10{sup 2}, enabling us to measure the linear susceptibility of the molecular array down to very low temperatures (13 mK). This method opens the possibility of applying ac susceptibility experiments to characterize two-dimensional arrays of single molecule magnets within a wide range of temperatures and frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spin current formation at the graphene/Pt interface for magnetization manipulation in magnetic nanodots

Spin electronic structure of the Graphene/Pt interface has been investigated. A large induced spin-orbit splitting (∼80 meV) of graphene π states with formation of non-degenerated Dirac-cone spin states at the K{sup ¯}-point of the Brillouin zone crossed with spin-polarized Pt 5d states at Fermi level was found. We show that this spin structure can be used as a spin current source in spintronic devices. By theoretical estimations and micromagnetic modeling based on the experimentally observed spin-orbit splitting, we demonstarte that the induced intrinsic magnetic field in such structure might be effectively used for induced remagnetization of the (Ni-Fe)-nanodots arranged atop the interface.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Thermal stability and magnetization switching of composite free layer with perpendicular magnetic anisotropy

We present a micromagnetic study of a ferromagnetically exchange-coupled composite free layer design for perpendicular magnetic tunnel junctions. The thermal stability factor and critical switching current density depend on the exchange coupling strength and effective anisotropy ratio between the sublayers of the composite free layer. The energy barrier increases with an increase of the exchange coupling strength until it reaches a plateau in the strong-coupling limit. An optimal exchange coupling strength exists that leads to the minimal critical switching current and a significant improvement of the figure of merit defined as the ratio between the energy barrier and critical switching current. This behavior is obtained for smaller device sizes with uniform reversal and larger sizes with domain wall reversal.

36 MATERIALS SCIENCE↗

Magnetic order and fluctuations in the quasi-two-dimensional planar magnet Sr( Co 1-x Ni x ) 2 As 2

We use neutron scattering to investigate spin excitations in Sr ( Co 1 - x Ni x ) 2 As 2 , which has a c -axis incommensurate helical structure of the two-dimensional (2D) in-plane ferromagnetic (FM) ordered layers for 0.013 ≤ x ≤ 0.25 . By comparing the wave vector and energy dependent spin excitations in helical ordered Sr ( Co 0.9 Ni 0.1 ) 2 As 2 and paramagnetic SrCo 2 As 2 , we find that Ni doping, while increasing lattice disorder in Sr ( Co 1 - x Ni x ) 2 As 2 , enhances quasi-2D FM spin fluctuations. However, our band structure calculations within the combined density functional theory and dynamic mean field theory ( DFT + DMFT ) failed to generate a correct incommensurate wave vector for the observed helical order from nested Fermi surfaces. Furthermore, since transport measurements reveal increased in-plane and c -axis electrical resistivity with increasing Ni doping and associated lattice disorder, we conclude that the helical magnetic order in Sr ( Co 1 - x Ni x ) 2 As 2 may arise from a quantum order-by-disorder mechanism through the itinerant electron mediated Ruderman-Kittel-Kasuya-Yosida (RKKY) interactions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fabrication of Low-Tortuosity Ultrahigh-Area-Capacity Battery Electrodes through Magnetic Alignment of Emulsion-Based Slurries

High energy–density, low–cost batteries are critically important to a variety of applications ranging from portable electronics to electric vehicles (EVs) and grid–scale storage. While tremendous research effort has been focused on new materials or chemistries with high energy–density potential, design innovations such as low–tortuosity thick electrodes are another promising path toward higher energy density and lower cost. Growing demand for fast–charging batteries has also highlighted the need for negative electrodes that can accept high rate charging without metal deposition; low tortuosity can be a benefit in this regard. However, a general and scalable fabrication method for low–tortuosity electrodes is currently lacking. Here an emulsion–based, magnetic–alignment approach to producing thick electrodes (>400 µm thickness) with ultrahigh areal capacity (up to ≈14 mAh cm –2 vs 2–4 mAh cm –2 for conventional lithium ion) is reported. The process is demonstrated for LiCoO 2 and meso–carbon microbead graphite. The LiCoO 2 cathodes are confirmed to have low tortuosity via DC–depolarization experiments and deliver high areal capacity (>10 mAh cm –2 ) in galvanostatic discharge tests at practical C–rates and model EV drive–cycle tests. Lastly, this simple fabrication method can potentially be applied to many other active materials to enable thick, low–tortuosity electrodes.

25 ENERGY STORAGE↗

Tumor Volume and Metabolism of Prostate Cancer Determined by Proton Magnetic Resonance Spectroscopic Imaging at 3T Without Endorectal Coil Reveal Potential Clinical Implications in the Context of Radiation Oncology;Prostate cancer; Magnetic resonance spectroscopic imaging; Radiation oncology; Tumor volume; Biomarkers

Purpose: To determine whether a relationship exists between the tumor volume (TV) or relative choline content determined using magnetic resonance spectroscopy imaging (MRSI) at 3T and the clinical prognostic parameters for patients with localized prostate cancer (PCa). Methods and Materials: A total of 72 men (mean age, 67.8 {+-} 6.2 years) were stratified as having low-risk (n = 26), intermediate-risk (n = 24), or high-risk (n = 22) PCa. MRSI was performed at 3T using a phased-array coil. Spectra are expressed as the total choline/citrate, total choline plus creatine/citrate, and total choline plus polyamines plus creatine/citrate ratios. The mean ratio of the most pathologic voxels and the MRSI-based TV were also determined. Results: The mean values of the total choline/citrate, total choline plus creatine/citrate, and total choline plus polyamine plus creatine/citrate ratios were greater for Stage T2b or greater tumors vs. Stage T2a or less tumors: 7.53 {+-} 13.60 vs. 2.31 {+-} 5.65 (p = .018), 8.98 {+-} 14.58 vs. 2.56 {+-} 5.70 (p = .016), and 10.32 {+-} 15.47 vs. 3.55 {+-} 6.16 (p = .014), respectively. The mean MRSI-based TV for Stage T2b or greater and Stage T2a or less tumors was significantly different (2.23 {+-} 2.62 cm{sup 3} vs. 1.26 {+-} 2.06 cm{sup 3}, respectively; p = .030). This TV correlated with increased prostate-specific antigen levels (odds ratio, 1.293; p = .012). Patients with high-risk PCa had a larger TV than did the patients with intermediate-risk PCa. A similar result was found for the intermediate-risk group compared with the low-risk group (odds ratio, 1.225; p = .041). Conclusion: Biomarkers expressing the relative choline content and TV were significant parameters for the localization of PCa and could be helpful for determining the prognosis more accurately.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic field screening in hydrogen-rich high-temperature superconductors

In the last few years, the superconducting transition temperature, T c , of hydrogen-rich compounds has increased dramatically, and is now approaching room temperature. However, the pressures at which these materials are stable exceed one million atmospheres and limit the number of available experimental studies. Superconductivity in hydrides has been primarily explored by electrical transport measurements, whereas magnetic properties, one of the most important characteristic of a superconductor, have not been satisfactory defined. Here, we develop SQUID magnetometry under extreme high-pressure conditions and report characteristic superconducting parameters for Im-3m-H 3 S and Fm-3m-LaH 10 —the representative members of two families of high-temperature superconducting hydrides. We determine a lower critical field H c1 of ~0.82 T and ~0.55 T, and a London penetration depth λ L of ~20 nm and ~30 nm in H 3 S and LaH 10 , respectively. The small values of λ L indicate a high superfluid density in both hydrides. These compounds have the values of the Ginzburg-Landau parameter κ ~12–20 and belong to the group of “moderate” type II superconductors, rather than being hard superconductors as would be intuitively expected from their high T c s.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron shear-flow-driven instability in magnetized plasmas with magnetic field gradient

It is found that the zero-order current associated with electron shear flow produces a drift wave in magnetized plasmas, which can become unstable under certain conditions. This wave will be particularly important in low density and low temperature plasmas of heavy ions. As an example, numerical estimates are presented for a barium plasma with parameters compatible with experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗