Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIBRARIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

A modern Monte Carlo investigation of the TG-43 dosimetry parameters for an {sup 125}I seed already having AAPM consensus data

Purpose: To investigate potential causes for differences in TG-43 brachytherapy dosimetry parameters in the existent literature for the model IAI-125A{sup 125}I seed and to propose new standard dosimetry parameters. Methods: The MCNP5 code was used for Monte Carlo (MC) simulations. Sensitivity of dose distributions, and subsequently TG-43 dosimetry parameters, was explored to reproduce historical methods upon which American Association of Physicists in Medicine (AAPM) consensus data are based. Twelve simulation conditions varying{sup 125}I coating thickness, coating mass density, photon interaction cross-section library, and photon emission spectrum were examined. Results: Varying{sup 125}I coating thickness, coating mass density, photon cross-section library, and photon emission spectrum for the model IAI-125A seed changed the dose-rate constant by up to 0.9%, about 1%, about 3%, and 3%, respectively, in comparison to the proposed standard value of 0.922 cGy h{sup −1} U{sup −1}. The dose-rate constant values by Solberg et al. [“Dosimetric parameters of three new solid core {sup 125}I brachytherapy sources,” J. Appl. Clin. Med. Phys. 3, 119–134 (2002)], Meigooni et al. [“Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGE™ {sup 125}I brachytherapy source,” Med. Phys. 29, 2152–2158 (2002)], and Taylor and Rogers [“An EGSnrc Monte Carlo-calculated database of TG-43 parameters,” Med. Phys. 35, 4228–4241 (2008)] for the model IAI-125A seed and Kennedy et al. [“Experimental and Monte Carlo determination of the TG-43 dosimetric parameters for the model 9011 THINSeed™ brachytherapy source,” Med. Phys. 37, 1681–1688 (2010)] for the model 6711 seed were +4.3% (0.962 cGy h{sup −1} U{sup −1}), +6.2% (0.98 cGy h{sup −1} U{sup −1}), +0.3% (0.925 cGy h{sup −1} U{sup −1}), and −0.2% (0.921 cGy h{sup −1} U{sup −1}), respectively, in comparison to the proposed standard value. Differences in the radial dose functions between the current study and both Solberg et al. and Meigooni et al. were <10% for r ≤ 5 cm, and increased for r > 5 cm with a maximum difference of 29% at r = 9 cm. In comparison to Taylor and Rogers, these differences were lower (maximum of 2% at r = 9 cm). For the similarly designed model 6711 {sup 125}I seed, differences did not exceed 0.5% for 0.5 ≤ r ≤ 10 cm. Radial dose function values varied by 1% as coating thickness and coating density were changed. Varying the cross-section library and source spectrum altered the radial dose function by 25% and 12%, respectively, but these differences occurred at r = 10 cm where the dose rates were very low. The 2D anisotropy function results were most similar to those of Solberg et al. and most different to those of Meigooni et al. The observed order of simulation condition variables from most to least important for influencing the 2D anisotropy function was spectrum, coating thickness, coating density, and cross-section library. Conclusions: Several MC radiation transport codes are available for calculation of the TG-43 dosimetry parameters for brachytherapy seeds. The physics models in these codes and their related cross-section libraries have been updated and improved since publication of the 2007 AAPM TG-43U1S1 report. Results using modern data indicated statistically significant differences in these dosimetry parameters in comparison to data recommended in the TG-43U1S1 report. Therefore, it seems that professional societies such as the AAPM should consider reevaluating the consensus data for this and others seeds and establishing a process of regular evaluations in which consensus data are based upon methods that remain state-of-the-art.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multigroup Examination of Nickel-Reflected HEU System

Critical configurations of HEU-MET-FAST-003 (HMF-003) from the International Criticality Safety Benchmark Evaluation Project Handbook were modeled for addition into the Verified, Archived Library of Inputs and Data maintained at Oak Ridge National Laboratory. HMF-003 contains models of a highly enriched uranium sphere with a spherical metal reflector of natural uranium, tungsten carbide, or nickel. For these simple models, good agreement is expected between the k eff calculated with continuous-energy (CE) and multigroup (MG) transport. However, using the CSAS5 sequence of the SCALE 6.2.4 package, the 8 in. thick nickel reflector model resulted in a difference of around 1.2 % Δ k . Results presented a clear indication of poor performance for the SCALE 252-group based on ENDF/B-VII.1 cross section library for this model. The bias was investigated over a range of nickel thickness and then compared with other MG libraries available in SCALE 6.2.4. As the nickel thickness increases, the MG k eff deviates from the CE result, confirming a performance issue with the MG calculation. Additionally, the reactions were compared between the two libraries to help determine the cause of k eff bias. Finally, additional MG libraries within SCALE 6.3 and based on ENDF/B-VII.1 and ENDF/B-VIII were reviewed. The 302-group and 1597-group result in significant improvements compared with the 252-group library. Nickel cross sections were modified from ENDF/B-VII.1 to ENDF/B-VIII. For the ENDF/B-VIII library, the deviation between the CE libraries and MG libraries is less pronounced than for ENDF/VII.1, except for the 1597-group. This examination clearly indicates the importance of validating calculations with applicable benchmark experiments and caution when using MG libraries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards Using Eshelby Calculations to Enhance Kinetic Model for Zirconium Hydride Precipitation

A C++ library (called Eshelby ) was implemented in fiscal year 2015 based upon the formulas documented in this report. The library implements a generalized version of Eshelby's inclusion problem. The library was written as a set of functions which can be called from another program; the principle intended use cases are kinetic models of precipitate formation in zirconium claddings where use of the Eshelby library provides needed elastic energy density calculations, as well as calculations of stress and strain in and around precipitates; it is intended that the library will be made open source. For isotropic inclusions in the form of oblate and prolate ellipsoids, the Eshelby library can be used for nearly any relevant/appropriate shape parameters to calculate strains, stresses and energy density at interior and exterior points. The Eshelby library uses a combination of analytical formulas and numerical routines making it very extensible. For example, the library can can easily be extended to include inclusions such as spheres since analytical expressions exist for the required elliptic integrals; similarly, general ellipsoids do not have analytical results for the required elliptic integrals but those integrals can be numerically evaluated and thus fit naturally into the Eshelby library. This report documents all formulas implemented in the Eshelby library and presents some demonstration calculations relevant to the intended application.

97 MATHEMATICS AND COMPUTING↗

Nuclear Data and Benchmarking Program: Nuclear Data Performance Assessment for Advanced Reactors

Over the last several Evaluated Nuclear Data File (ENDF)/B releases, many updates have been introduced to the nuclear data libraries that can significantly change computational results. These changes can be particularly important for advanced reactor concepts, which are not as thoroughly investigated as those used in light water reactor (LWR) systems. Therefore, a performance assessment of the ENDF/B libraries using the SCALE 6.2.3 code package was conducted under the auspices of the U.S., Department of Energy Office of Nuclear Energy (DOE-NE). The following systems relevant to the advanced reactor community were chosen as subject for investigation in this report: sodium cooled fast reactor systems, graphite moderated high temperature gas-cooled reactors, and several molten salt reactor models. At first, the similarity of the integral performance of the ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear data libraries caused by compensating errors in important differential data was demonstrated. In calculations for a shipping container of high-assay low enriched uranium, the data of individual isotopes were systematically swapped between the two ENDF/B libraries. An eigenvalue difference of up to 450 pcm was found due to the use of 235 U and 238 U from one library and 1 H and 16 O from the other library. This clearly demonstrates a cross-correlation between reaction data sets of different isotopes within a library that should be reported in the evaluations. For sodium-cooled fast reactor (SFR) fuel assemblies, significant eigenvalue (k inf ) differences (200– 450 pcm) were found between calculations using the 2011 ENDF/B-VII.1 data and 2018 ENDF/B-VIII.0 data. These differences were mainly caused by updates of 238 U and 239 Pu neutron cross sections. Results from the multigroup (MG) calculations further revealed that the group structure of the applied MG library strongly influences the MG bias due to the importance of an appropriate energy resolution of the resonances in higher energy ranges. The application of previously used MG libraries requires new verification for advanced reactor simulation in comparisons with reference continuous-energy calculations. Nuclear data uncertainty analyses of these SFR systems resulted in eigenvalue uncertainties between 1,400 and 1,800 pcm, which are three to four times higher than corresponding uncertainties in light water reactor (LWR) systems. The main contributor to this uncertainty was found to be inelastic scattering on 238 U, which shows an uncertainty of up to 50% in the fast energy range. Other important contributors are the scattering reactions of 56 Fe and 23 Na which have so far not appeared in LWR analysis. Since the largest contribution to the eigenvalue uncertainty of SFR systems is coming from scattering reactions, it is expected that uncertainties in the angular scattering distributions also have a significant impact. Those uncertainties are, however, not available for the majority of nuclides, and the capabilities to determine sensitivities to this data are currently underdeveloped. For two graphite moderated high temperature gas-cooled reactor (HTGR) benchmarks, only the ENDF/BVII. 1 calculations resulted in consistent eigenvalues (k eff ) with the corresponding experimental measurements. Eigenvalue differences of about 1,000 pcm were found between the 2006 ENDF/B-VII.0 data and the 2011 ENDF/B-VII.1 data, primarily due to an updated carbon capture cross section in the thermal energy range in the later ENDF/B release. The ENDF/B-VIII.0 eigenvalue was larger than the ENDF/B-VII.1 eigenvalue by about 300 pcm mainly due to updates in multiple 235 U neutron cross sections, with offsetting updates in the 238 U cross sections. With ENDF/B-VIII.0, graphite can be modeled as perfect crystal or with two different porosities. The choice of the graphite evaluation can have a significant influence of the eigenvalue. For a HTGR benchmark, maximum eigenvalue differences as high as 650 pcm due to different porosities were observed. More detailed studies of the impact of the porosity are necessary while considering that the graphite porosity can vary between the used materials and changes as a function of neutron fluence. xii The uncertainty of the HTGR eigenvalues due to nuclear data uncertainties was found between 500 and 600 pcm, with the top contributor being the neutron multiplicity of 235 U. A gap in the form of missing uncertainties in graphite thermal scattering data, that might have significant impact on HTGR reactors, was identified. This gap is being investigated by the DOE-NE Nuclear Data and Benchmarking Program, as documented in a separate report The fast spectrum molten salt reactor calculations revealed similar comparisons as for the SFR assemblies. The eigenvalue uncertainties were significantly influenced by inelastic scattering on 238 U, while the impact of angular scattering distributions is unknown. For the graphite and zirconium hydride moderated system, eigenvalue uncertainties of up to 700 pcm were observed, requiring in depth analyses of the cross sections and corresponding uncertainties of the included materials. In general, it was observed that the flux spectra of the various molten salt reactor systems show significant differences, even between a fresh state and a depleted state. The choice of the energy group structure of MG calculations is therefore highly relevant; the applicability of previously used MG libraries needs to be verified. Due the unavailability of pin power measurements of advanced reactor systems, pin power calculations with both ENDF/B-VII.1 and VIII.0 data were performed for a light water reactor and compared to corresponding measurements. Both calculations show good agreement with the measurements. A comparison between the ENDF/B-VII.1 and VIII.0 results revealed small differences, mostly in the range of about 0.2%.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ENDF/B-VII.1 Nuclear Data for Science and Technology: Cross Sections, Covariances, Fission Product Yields and Decay Data

The ENDF/B-VII.1 library is our latest recommended evaluated nuclear data file for use in nuclear science and technology applications, and incorporates advances made in the five years since the release of ENDF/B-VII.0. These advances focus on neutron cross sections, covariances, fission product yields and decay data, and represent work by the US Cross Section Evaluation Working Group (CSEWG) in nuclear data evaluation that utilizes developments in nuclear theory, modeling, simulation, and experiment. The principal advances in the new library are: (1) An increase in the breadth of neutron reaction cross section coverage, extending from 393 nuclides to 423 nuclides; (2) Covariance uncertainty data for 190 of the most important nuclides, as documented in companion papers in this edition; (3) R-matrix analyses of neutron reactions on light nuclei, including isotopes of He, Li, and Be; (4) Resonance parameter analyses at lower energies and statistical high energy reactions for isotopes of Cl, K, Ti, V, Mn, Cr, Ni, Zr and W; (5) Modifications to thermal neutron reactions on fission products (isotopes of Mo, Tc, Rh, Ag, Cs, Nd, Sm, Eu) and neutron absorber materials (Cd, Gd); (6) Improved minor actinide evaluations for isotopes of U, Np, Pu, and Am (we are not making changes to the major actinides {sup 235,238}U and {sup 239}Pu at this point, except for delayed neutron data and covariances, and instead we intend to update them after a further period of research in experiment and theory), and our adoption of JENDL-4.0 evaluations for isotopes of Cm, Bk, Cf, Es, Fm, and some other minor actinides; (7) Fission energy release evaluations; (8) Fission product yield advances for fission-spectrum neutrons and 14 MeV neutrons incident on {sup 239}Pu; and (9) A new decay data sublibrary. Integral validation testing of the ENDF/B-VII.1 library is provided for a variety of quantities: For nuclear criticality, the VII.1 library maintains the generally-good performance seen for VII.0 for a wide range of MCNP simulations of criticality benchmarks, with improved performance coming from new structural material evaluations, especially for Ti, Mn, Cr, Zr and W. For Be we see some improvements although the fast assembly data appear to be mutually inconsistent. Actinide cross section updates are also assessed through comparisons of fission and capture reaction rate measurements in critical assemblies and fast reactors, and improvements are evident. Maxwellian-averaged capture cross sections at 30 keV are also provided for astrophysics applications. We describe the cross section evaluations that have been updated for ENDF/B-VII.1 and the measured data and calculations that motivated the changes, and therefore this paper augments the ENDF/B-VII.0 publication 'ENDF/B-VII.0: Next Generation Evaluated Nuclear Data Library for Nuclear Science and Technology,' Nuclear Data Sheets 107, 2931 (2006).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of Fuel Depletion Chain Simplification to Experiment Analysis in the Advanced Test Reactor

An irradiation experiment analysis can be informed by high-fidelity reactor engineering depletion results, but this comes at a computational cost. Applying depletion chain simplification to the advanced test reactor driver fuel before performing experiment depletions permits their programmatic parameters to be calculated faster, with a small penalty to accuracy. Here, this work contrasts the results of two irradiation experiments with different neutronic characteristics. Overall, the simplified nuclide library produced using a simple one-group microscopic cross-section library for a pressurized water reactor in the depletion chain simplification process performed comparably in terms of accuracy and runtime to the simplified nuclide library produced using a three-group microscopic cross-section library generated specifically for the advanced test reactor experiments being modeled. This is attributed to the additional nuclides and transmutation pathways preserved in the one-group cross-section library, which has data for 297 nuclides, compared to the three-group cross-section library, which has data for 217 nuclides. This indicates that a cross-section library with more nuclides is better than a cross-section library with fewer nuclides for the depletion chain simplification process, even if the cross-section library with fewer nuclides better represents the flux spectrum of the system being considered.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation of Scale 6.2 criticality calculations using KENO V.A and KENO-VI - 14603

SCALE 6.2 provides enhancements for criticality calculations relative to SCALE 6.1, especially with updated nuclear data libraries, resonance self-shielding options for multigroup (MG) calculations, and problem-dependent temperature treatments for continuous-energy (CE) calculations. Benchmark experiments from the International Criticality Safety Benchmark Evaluation Project that are available in the Oak Ridge National Laboratory Verified, Archived, Library of Inputs and Data (VALID) were applied in this validation effort to examine the impact of the SCALE 6.2 enhancements. Over 300 cases are drawn from the VALID library for testing KENO V.a, and a more limited set of approximately 50 configurations is used for validation of KENO-VI. A total of 401 unique critical experiments are used in this validation effort. In some cases, the KENO V.a models were converted to KENO-VI models so that the performance of both codes could be assessed for the same systems. Validation results for the SCALE 6.2 ENDF/B-VII.1 nuclear data libraries are presented, including MG neutron data in 56- and 252-group structures as well as CE data. The performance of all three multipurpose neutron libraries in calculating k{sub eff} is examined with critical experiment models covering a wide range of fuels, moderators, reflectors, absorbers, and neutron spectra. The SCALE 6.2 ENDF/B-VII.1 coupled neutron-photon library, primarily developed for shielding applications with 200 neutron groups and 47 gamma groups, provides additional energy resolution for fast systems relative to the MG neutron libraries which were developed to produce low biases for thermal neutron systems. The applicability of this library to criticality calculations for fast neutron spectrum systems is not investigated here but will be addressed in the final SCALE 6.2 validation report. The results of these calculations demonstrate that SCALE 6.2 generally provides lower biases than SCALE 6.1 and that the two versions of KENO provide equivalent results on the same suite of problems. SCALE 6.2 also includes an updated neutron cross-section covariance library based on the ENDF/B-VII.1 covariance data. The effect of these updated covariances on the uncertainty in k{sub eff} due to cross section uncertainties is also presented for some cases. A more thorough investigation of the updated covariance data is presented in a companion paper. (authors)

42 ENGINEERING↗

Multiscale Universal Interface: A concurrent framework for coupling heterogeneous solvers

Graphical abstract: - Abstract: Concurrently coupled numerical simulations using heterogeneous solvers are powerful tools for modeling multiscale phenomena. However, major modifications to existing codes are often required to enable such simulations, posing significant difficulties in practice. In this paper we present a C++ library, i.e. the Multiscale Universal Interface (MUI), which is capable of facilitating the coupling effort for a wide range of multiscale simulations. The library adopts a header-only form with minimal external dependency and hence can be easily dropped into existing codes. A data sampler concept is introduced, combined with a hybrid dynamic/static typing mechanism, to create an easily customizable framework for solver-independent data interpretation. The library integrates MPI MPMD support and an asynchronous communication protocol to handle inter-solver information exchange irrespective of the solvers' own MPI awareness. Template metaprogramming is heavily employed to simultaneously improve runtime performance and code flexibility. We validated the library by solving three different multiscale problems, which also serve to demonstrate the flexibility of the framework in handling heterogeneous models and solvers. In the first example, a Couette flow was simulated using two concurrently coupled Smoothed Particle Hydrodynamics (SPH) simulations of different spatial resolutions. In the second example, we coupled the deterministic SPH method with the stochastic Dissipative Particle Dynamics (DPD) method to study the effect of surface grafting on the hydrodynamics properties on the surface. In the third example, we consider conjugate heat transfer between a solid domain and a fluid domain by coupling the particle-based energy-conserving DPD (eDPD) method with the Finite Element Method (FEM)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SEAS Communication Engine: An Extensible, Flexible Wrapper for Co-Simulation Agents

When modeling and analyzing the power grid and other large scale systems, researchers often express scenarios as optimization problems and feed them into advanced software solvers. In order to allow multiple solvers to communicate with each other and share data from different domains, the National Renewable Energy Laboratory (NREL) and associated Department of Energy (DOE) labs have developed a software framework called the Hierarchical Engine for Large-scale Infrastructure Co-Simulation (HELICS). HELICS allows cosimulation via a collection of client libraries for different languages that can be called from the appropriate optimization software. However, these client libraries do not provide a higher level of abstraction beyond reading and writing data off of the shared HELICS bus. In this paper, we describe a new software library called the SEAS Communication Engine that exposes a higher-level API for running cosimulation problems. The SEAS Engine provides a class-based abstraction on top of the Python HELICS client, in order to allow users to implement their domain-specific cosimulations without needing to interact with core HELICS primitives. This will make adoption of HELICS and cosimulation in general easier, by exposing a simpler API. In the second part of the paper, we validate our library on a collection of different simulation examples, including the canonical IEEE 13 Bus Feeder. Lastly, we demonstrate using the SEAS Engine to directly call domain-specific code written in the Julia programming language. Our hope is that this will serve as a template for easily calling software in different programming languages via the SEAS Engine, thereby avoiding code duplication and complexity.

co-simulation↗

Moving toward automated µFTIR spectra matching for microplastic identification: addressing false identifications and improving accuracy

Abstract Infrared spectroscopy is a widely used tool for studying microplastics and identifying microparticles. Researchers rely on spectral libraries to differentiate between synthetic and natural materials. Unfortunately, spectral library matching is not perfect, and best practices require researchers to use time consuming, manual peak matching to assess spectral matches. Moving toward automated matching requires increased confidence in the matching process. Using spectra matching software may increase the efficiency of particle identification, however some matching strategies may confuse natural materials such as cotton, silk, and plant matter with common classes of synthetics such as polyesters and polyamides. In this experiment, we prepared 22 pristine sample materials from natural and synthetic sources and measured micro-Fourier transform infrared (µFTIR) spectra in transmission mode for each sample using a Thermo Nicolet iN10 MX instrument. The collected spectra were then input into two spectral library matching systems (Omnic Picta and Open Specy), using a total of five identification routines. Next, we placed a subset of four pristine microplastic materials in a biologically active river system for two weeks to simulate environmental samples. These simulated environmental samples were processed using 10% hydrogen peroxide for 24 h to remove organic contamination and then identified using the strongest performing library. We found that libraries with fewer sample spectra produced lower correlation matches and that using derivative correction greatly reduced the number of inaccuracies in identifying materials as either natural or synthetic. We also found that environmental fouling reduced the correlation value of library matches when compared to pristine particles, however the effect was not consistent across the four materials tested. Overall, we found that the accuracy of automated library matching in the tested systems and processing routines varied from 64.1 to 98.0% for distinguishing between natural and synthetic materials, and that a high Hit Quality Index (HQI) did not always correlate with accuracy. These results are important for the microplastic field, demonstrating a need to rigorously test spectral libraries and processing routines with known materials to ensure identification accuracy.

Kozloski, Rachel↗

Disposal Systems Evaluation Framework DSEF User Manual (V.3.0)

The Disposal Systems Evaluation Framework (DSEF) has been developed at Lawrence Livermore National Laboratory (LLNL) to formalize and facilitate the development and documentation of repository conceptual design options for a range of waste forms, geologic environments, repository design concepts, and repository operating modes. DSEF is one component of the Engineered Barrier System (EBS) family of work packages at several national laboratories led by Sandia National Laboratories (SNL), in support of the DOE Office of Nuclear Energy, specifically of the Used Fuel Disposition (UFD) Campaign within the Office of Used Nuclear Fuel Disposition Research and Development (NE-53). DSEF is a knowledge management system that allows the user to intelligently access and draw data from a case library of hundreds of completed thermal analyses (currently 721 cases in the library), and draw input from databases of material properties and repository development cost data (currently the data in these databases are drawn from more than 100 references). The core functionality of DSEF is provided by a Microsoft Office Excel 2010 workbook with macros and form controls that create a structured environment and walk the user through the steps of creating the input data required to perform disposal system evaluations internally and by interfacing with external programs. The user can choose to work with built-in data from the case library of previous analysis cases, from the material property databases, or can define their own input descriptions and data. DSEF uses the Excel worksheet protection (implemented on a sheet by sheet basis) to prevent inadvertent over-writing of formulas with data. When worksheet protection is enabled, the user can see all underlying formulas, and enter data in unprotected cells (the unprotected cells generally correspond to the yellow highlighted cells). Worksheet protection also prevents restructuring the files (adding or deleting rows or columns) and changing the formatting, as well as preventing access to the Visual Basic Editor to prevent modification of the macros. If the user needs to modify the worksheet structure, formulas, or macros, they can contact LLNL to get the password to unprotect the worksheets. However, care should be taken in making any modifications, since the macros and formulas are dependent in some cases on the current structure, range names, and macro subroutines DSEF is set up to retrieve the results of external thermal analysis program runs, summarize them graphically, and provide a template for adding the new results to the Case Library. The Case Library worksheet in DSEF is set up to create a Case Library data record for each new analysis case, at the top of the list of prior cases. Therefore, a separate DSEF file (with unique name) should be saved for each run that is to be archived. Users should submit a copy of their DSEF files to LLNL so that their results can be added to the overall Case Library and made available to other laboratories and stakeholders. LLNL will maintain the DSEF Case Library and make the most current files available on the SNL SharePoint site. The Revision History sheet documents the file evolution. One of the key objectives of DSEF is to allow the user to compare the results of thermal analyses to the thermal constraints of the design components. These comparisons can then be used to consider design, layout, and operating mode modifications to find combinations that can meet the thermal constraints for a given combination of waste form, geologic medium, surface storage time, and system concept of operation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Towards Vendor and Operating System Independence of USB-based portable multi-channel analyzers

The nuclear measurements group is called on to develop portable, user friendly systems that performs at, or near, laboratory standards. These systems typically consist of a detector and a USB-based multi-channel analyzer. An ORTEC digi-Base is an example of a USB-based portable multi-channel analyzer with 14-pin photomultiplier tube base for gamma-ray spectroscopy applications with NaI(Tl) and other scintillation detectors. Operating system independence - we want to be able to develop applications that are 'future-proof' and can run on the best hardware for the job: desktop, laptop, tablet, phone, or embedded device. To do that we need our software to be operating system independent. Hardware vendor independence - to use the most appropriate equipment for the job, while still maintaining our rapid method development, we would like our software that uses this equipment to be independent of the specific vendor or model of the hardware. To do that we need a common interface to each vendor's equipment (high voltage, gain, start, stop, clear, etc.) In prior work, we were able to use an existing library to communicate with an ORTEC digi-base via Linux and Android. However the application developed did not have a user friendly front-end. Part of this work was to develop a simple user interface to control the settings of the hardware from Android. While OS independence is the final goal, another goal is standardized software for user-application development. For current purposes those standard systems are Windows 7, Windows 10, and Python 3. Our next step was to develop a common software interface between a front-end user interface and back-end hardware communication software. This was done using Python's Ctypes library. Ctypes is a foreign function library for Python. It provides C compatible data types, and allows calling functions in DLLs or shared libraries. It can be used to wrap these libraries in pure Python. Ctypes exports the cdll, and Windows windll and oledll objects, for loading dynamic link libraries. You load libraries by accessing them as attributes of these objects. cdll loads libraries which export functions using the standard cdecl calling convention. The first steps of developing the common software interface have been done. Once the software interface has been developed the next goal will be to develop hardware specific back-end software that way rapid user facing software can be developed using equipment that is 'on-hand' and once finished prototyping, the 'best' hardware can be chosen for the specific implementation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-J-131: Augmenting Atlas-Based Segmentation by Incorporating Image Features Proximal to the Atlas Contours

Purpose: For facilitating the current automatic segmentation, in this work we propose a narrow-shell strategy to enhance the information of each contour in the library and to improve the accuracy of the exiting atlas-based approach. Methods: In setting up an atlas-based library, we include not only the coordinates of contour points, but also the image features adjacent to the contour. 139 planning CT scans with normal appearing livers obtained during their radiotherapy treatment planning were used to construct the library. The CT images within the library were registered each other using affine registration. A nonlinear narrow shell with the regional thickness determined by the distance between two vertices alongside the contour. The narrow shell was automatically constructed both inside and outside of the liver contours. The common image features within narrow shell between a new case and a library case were first selected by a Speed-up Robust Features (SURF) strategy. A deformable registration was then performed using a thin plate splines (TPS) technique. The contour associated with the library case was propagated automatically onto the images of the new patient by exploiting the deformation field vectors. The liver contour was finally obtained by employing level set based energy function within the narrow shell. The performance of the proposed method was evaluated by comparing quantitatively the auto-segmentation results with that delineated by a physician. Results: Application of the technique to 30 liver cases suggested that the technique was capable of reliably segment organs such as the liver with little human intervention. Compared with the manual segmentation results by a physician, the average and discrepancies of the volumetric overlap percentage (VOP) was found to be 92.43%+2.14%. Conclusion: Incorporation of image features into the library contours improves the currently available atlas-based auto-contouring techniques and provides a clinically practical solution for auto-segmentation. This work is supported by NIH/NIBIB (1R01-EB016777), National Natural Science Foundation of China (No.61471226 and No.61201441), Research funding from Shandong Province (No.BS2012DX038 and No.J12LN23), and Research funding from Jinan City (No.201401221 and No.20120109)

60 APPLIED LIFE SCIENCES↗

SU-E-J-238: First-Order Approximation of Time-Resolved 4DMRI From Cine 2DMRI and Respiratory-Correlated 4DMRI

Purpose: Cine 2DMRI is useful in MR-guided radiotherapy but it lacks volumetric information. We explore the feasibility of estimating timeresolved (TR) 4DMRI based on cine 2DMRI and respiratory-correlated (RC) 4DMRI though simulation. Methods: We hypothesize that a volumetric image during free breathing can be approximated by interpolation among 3DMRI image sets generated from a RC-4DMRI. Two patients’ RC-4DMRI with 4 or 5 phases were used to generate additional 3DMRI by interpolation. For each patient, six libraries were created to have total 5-to-35 3DMRI images by 0–6 equi-spaced tri-linear interpolation between adjacent and full-inhalation/full-exhalation phases. Sagittal cine 2DMRI were generated from reference 3DMRIs created from separate, unique interpolations from the original RC-4DMRI. To test if accurate 3DMRI could be generated through rigid registration of the cine 2DMRI to the 3DMRI libraries, each sagittal 2DMRI was registered to sagittal cuts in the same location in the 3DMRI within each library to identify the two best matches: one with greater lung volume and one with smaller. A final interpolation between the corresponding 3DMRI was then performed to produce the first-order-approximation (FOA) 3DMRI. The quality and performance of the FOA as a function of library size was assessed using both the difference in lung volume and average voxel intensity between the FOA and the reference 3DMRI. Results: The discrepancy between the FOA and reference 3DMRI decreases as the library size increases. The 3D lung volume difference decreases from 5–15% to 1–2% as the library size increases from 5 to 35 image sets. The average difference in lung voxel intensity decreases from 7–8 to 5–6 with the lung intensity being 0–135. Conclusion: This study indicates that the quality of FOA 3DMRI improves with increasing 3DMRI library size. On-going investigations will test this approach using actual cine 2DMRI and introduce a higher order approximation for improvements. This study is in part supported by NIH (U54CA137788 and U54CA132378)

60 APPLIED LIFE SCIENCES↗

Enabling particle applications for exascale computing platforms

The Exascale Computing Project (ECP) is invested in co-design to assure that key applications are ready for exascale computing. Within ECP, the Co-design Center for Particle Applications (CoPA) is addressing challenges faced by particle-based applications across four “sub-motifs”: short-range particle–particle interactions (e.g., those which often dominate molecular dynamics (MD) and smoothed particle hydrodynamics (SPH) methods), long-range particle–particle interactions (e.g., electrostatic MD and gravitational N-body), particle-in-cell (PIC) methods, and linear-scaling electronic structure and quantum molecular dynamics (QMD) algorithms. Our crosscutting co-designed technologies fall into two categories: proxy applications (or “apps”) and libraries. Proxy apps are vehicles used to evaluate the viability of incorporating various types of algorithms, data structures, and architecture-specific optimizations and the associated trade-offs; examples include ExaMiniMD, CabanaMD, CabanaPIC, and ExaSP2. Libraries are modular instantiations that multiple applications can utilize or be built upon; CoPA has developed the Cabana particle library, PROGRESS/BML libraries for QMD, and the SWFFT and fftMPI parallel FFT libraries. Success is measured by identifiable “lessons learned” that are translated either directly into parent production application codes or into libraries, with demonstrated performance and/or productivity improvement. The libraries and their use in CoPA’s ECP application partner codes are also addressed.

97 MATHEMATICS AND COMPUTING↗

Working with Multiple MPIs: Overcoming ABI Incompatibility

Scientific applications rely on third-party libraries, which may have multiple implementations. While sharing an application programming interface (API), many of these implementations do not have a shared application binary interface (ABI) and require recompiling. Recompiling can be a long and complex process and sometimes not even an option when the application is shipped binary only. ABI incompatibility strikes at the heart of portability, productivity, and performance by (1) impeding application execution across different HPC and Cloud systems; (2) adding developer hours rebuilding an application; and (3) not taking advantage of host-optimized libraries. This tutorial teaches attendees a portable way to address ABI incompatibility in MPI using the Wi4MPI library. Wi4MPI translates the ABI dynamically from the MPI library used to build the application to a different MPI library available at run time. With Wi4MPI, HPC practitioners can break the portability barrier imposed by ABI incompatibility, potentially increase performance, and increase user productivity. The tutorial is broken down in three components: (1) Understanding ABI compatibility in MPI; (2) Translating MPI libraries dynamically; and (3) Applying dynamic translation to key use cases in HPC, including Containers. If you use more than one MPI library or supercomputer, this tutorial is for you.

97 MATHEMATICS AND COMPUTING↗

Solar Energy Extension Project

The town of Stratford plans to develop and own a 6 kilowatt (kW) solar array on the roof of a municipal-owned public pavilion on the town green. A SolarEdge level 2 EV charging station will be installed at the pavilion to be used by the public. The charging station will have one charging port. The town will install 3 air source heat pumps in the library located adjacent to the pavilion to reduce the use of propane to heat the library. The town will install 4 air source heat pumps in the Town Hall to reduce the use of #2 heating oil to heat the facility. The 6 kW solar array will provide electricity to the library to offset electricity usage, and when an EV plugs into the charging station the solar will provide electricity to the charging station. There is no ground disturbance or ground trenching associated with this project. The 6 kW solar array on the roof of the pavilion will include 20 (390) watt all black panels. A SolarEdge level 2 EV charger will be installed at the pavilion with the 240 V inverter. The solar array will provide electricity to the library and when a vehicle plugs into the EV charger the solar array will switch to power the charger. Any excess electricity that is generated by the array and not used by the library or the EV charger will be fed onto the grid and the town will receive a net metering credit applied towards future consumption. There is no ground disturbance associated with the EV charger or solar array, and the town will install signage to direct the public to the charger. The library will install 2 (18,000) BTU ductless air source heat pumps and 1 (24,000) BTU unit. This will significantly reduce the amount of propane required to heat the library. The Town Hall will install 2 (36,000) BTU ductless air source heat pumps and 2 (9,000) BTU units to reduce the amount of #2 heating oil required to heat the building.

14 SOLAR ENERGY↗