Correlation of Injury Simulation with Clinical Assessment of Traumatic Brain Injury

This report contains a summary of our efforts to correlate head injury simulations predicting intracranial fluid cavitation with clinical assessments of brain injury from blunt impact to the head. Magnetic resonance imaging (MRI) data, collected on traumatic brain injury (TBI) subjects by researchers at the MIND Institute of New Mexico, was acquired for the current work. Specific blunt impact TBI case histories were selected from the TBI data for further study and possible correlation with simulation. Both group and single-subject case histories were examined. We found one single-subject case that was particularly suited for correlation with simulation. Diffusion tensor image (DTI) analysis of the TBI subject identified white matter regions within the brain displaying reductions in fractional anisotropy (FA), an indicator of local damage to the white matter axonal structures. Analysis of functional magnetic resonance image (fMRI) data collected on this individual identified localized regions of the brain displaying hypoactivity, another indicator of brain injury. We conducted high fidelity simulations of head impact experienced by the TBI subject using the Sandia head-neck-torso model and the shock physics computer code CTH. Intracranial fluid cavitation predictions were compared with maps of DTI fractional anisotropy and fMRI hypoactivity to assess whether a possible correlation exists. The ultimate goal of this work is to assess whether one can correlate simulation predictions of intracranial fluid cavitation with the brain injured sites identified by the fMRI and DTI analyses. The outcome of this effort is described in this report.

59 BASIC BIOLOGICAL SCIENCES↗

Correlation of Injury Simulation with Clinical Assessment of Traumatic Brain Injury

This report contains a summary of our efforts to correlate head injury simulations predicting intracranial fluid cavitation with clinical assessments of brain injury from blunt impact to the head. Magnetic resonance imaging (MRI) data, collected on traumatic brain injury (TBI) subjects by researchers at the MIND Institute of New Mexico, was acquired for the current work. Specific blunt impact TBI case histories were selected from the TBI data for further study and possible correlation with simulation. Both group and single-subject case histories were examined. We found one single-subject case that was particularly suited for correlation with simulation. Diffusion tensor image (DTI) analysis of the TBI subject identified white matter regions within the brain displaying reductions in fractional anisotropy (FA), an indicator of local damage to the white matter axonal structures. Analysis of functional magnetic resonance image (fMRI) data collected on this individual identified localized regions of the brain displaying hypoactivity, another indicator of brain injury. We conducted high fidelity simulations of head impact experienced by the TBI subject using the Sandia head-neck-torso model and the shock physics computer code CTH. Intracranial fluid cavitation predictions were compared with maps of DTI fractional anisotropy and fMRI hypoactivity to assess whether a possible correlation exists. The ultimate goal of this work is to assess whether one can correlate simulation predictions of intracranial fluid cavitation with the brain injured sites identified by the fMRI and DTI analyses. The outcome of this effort is described in this report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization considerations for optical systems II; Proceedings of the Meeting, San Diego, CA, Aug. 9-11, 1989

Various papers on polarization considerations for optical systems are presented. Individual topics addressed include: use of polarization methods in earth resources investigation, measurements of polarization scattering in the vacuum UV, the Space Shuttle as a polarization observation platform, analysis of spatial pseudodepolarizers in imaging systems, analysis of polarization effects in optical systems, and a low-polarization solar vector magnetograph. Consideration is given to polarization effects on astronomical spatial interferometry, measurement of the instrumental polarization of a high-resolution UV spectrometer, and the use of KD(asterisk)P modulators for polarization measurements of the sun.

Chipman, Russell A.↗

Artificial intelligence for geologic mapping with imaging spectrometers

This project was a three year study at the Center for the Study of Earth from Space (CSES) within the Cooperative Institute for Research in Environmental Science (CIRES) at the University of Colorado, Boulder. The goal of this research was to develop an expert system to allow automated identification of geologic materials based on their spectral characteristics in imaging spectrometer data such as the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). This requirement was dictated by the volume of data produced by imaging spectrometers, which prohibits manual analysis. The research described is based on the development of automated techniques for analysis of imaging spectrometer data that emulate the analytical processes used by a human observer. The research tested the feasibility of such an approach, implemented an operational system, and tested the validity of the results for selected imaging spectrometer data sets.

Kruse, F. A.↗

Thermographic Imaging of the Space Shuttle During Re-Entry Using a Near Infrared Sensor

High resolution calibrated near infrared (NIR) imagery of the Space Shuttle Orbiter was obtained during hypervelocity atmospheric re-entry of the STS-119, STS-125, STS-128, STS-131, STS-132, STS-133, and STS-134 missions. This data has provided information on the distribution of surface temperature and the state of the airflow over the windward surface of the Orbiter during descent. The thermal imagery complemented data collected with onboard surface thermocouple instrumentation. The spatially resolved global thermal measurements made during the Orbiter s hypersonic re-entry will provide critical flight data for reducing the uncertainty associated with present day ground-to-flight extrapolation techniques and current state-of-the-art empirical boundary-layer transition or turbulent heating prediction methods. Laminar and turbulent flight data is critical for the validation of physics-based, semi-empirical boundary-layer transition prediction methods as well as stimulating the validation of laminar numerical chemistry models and the development of turbulence models supporting NASA s next-generation spacecraft. In this paper we provide details of the NIR imaging system used on both air and land-based imaging assets. The paper will discuss calibrations performed on the NIR imaging systems that permitted conversion of captured radiant intensity (counts) to temperature values. Image processing techniques are presented to analyze the NIR data for vignetting distortion, best resolution, and image sharpness. Keywords: HYTHIRM, Space Shuttle thermography, hypersonic imaging, near infrared imaging, histogram analysis, singular value decomposition, eigenvalue image sharpness

Zalameda, Joseph N.↗

Multimodal X-ray nano-spectromicroscopy analysis of chemically heterogeneous systems

Abstract Understanding the nanoscale chemical speciation of heterogeneous systems in their native environment is critical for several disciplines such as life and environmental sciences, biogeochemistry, and materials science. Synchrotron-based X-ray spectromicroscopy tools are widely used to understand the chemistry and morphology of complex material systems owing to their high penetration depth and sensitivity. The multidimensional (4D+) structure of spectromicroscopy data poses visualization and data-reduction challenges. This paper reports the strategies for the visualization and analysis of spectromicroscopy data. We created a new graphical user interface and data analysis platform named XMIDAS (X-ray multimodal image data analysis software) to visualize spectromicroscopy data from both image and spectrum representations. The interactive data analysis toolkit combined conventional analysis methods with well-established machine learning classification algorithms (e.g. nonnegative matrix factorization) for data reduction. The data visualization and analysis methodologies were then defined and optimized using a model particle aggregate with known chemical composition. Nanoprobe-based X-ray fluorescence (nano-XRF) and X-ray absorption near edge structure (nano-XANES) spectromicroscopy techniques were used to probe elemental and chemical state information of the aggregate sample. We illustrated the complete chemical speciation methodology of the model particle by using XMIDAS. Next, we demonstrated the application of this approach in detecting and characterizing nanoparticles associated with alveolar macrophages. Our multimodal approach combining nano-XRF, nano-XANES, and differential phase-contrast imaging efficiently visualizes the chemistry of localized nanostructure with the morphology. We believe that the optimized data-reduction strategies and tool development will facilitate the analysis of complex biological and environmental samples using X-ray spectromicroscopy techniques.

36 MATERIALS SCIENCE↗

Nanometer Scale Imaging to Develop Quantitative Descriptors of Bipolar Membrane Junction Structure

Swings in pH can be achieved by electrically polarizing a bipolar membrane (BPM) to drive water dissociation at the BPM junction for electrochemical conversion and separation processes. BPM junction design is critical to tailor performance for specific applications; however, characterization techniques capable of resolving the nanometer scale physical structure of the junction are limited. We present sample preparation, imaging, and analysis workflows that are adaptable to a variety of BPM junction architectures. Atomic force microscopy produces BPM junction images with nanometer scale lateral resolution for samples with and without a graphene oxide water dissociation catalyst in the junction. Subsequent image segmentation and analysis quantify line edge roughness and catalyst layer thickness as descriptors of junction structure. Comparison of pre- and post-electrodialysis junctions suggests electric field-induced alignment of catalyst particles during electrodialysis. This characterization workflow can inform manufacturing protocols, computational modeling, and failure mode analysis for next-generation BPMs.

97 MATHEMATICS AND COMPUTING↗

Analysis of High Contrast Imaging Techniques for Space Based Direct Planetary Imaging

We report on our ongoing investigations of a number of techniques for direct detection and imaging of Earth-like planets around nearby stellar sources. Herein, we give a quantitative analysis of these techniques and compare and contrast them via computer simulations. The techniques we will be reporting on are Bracewell Interferometry, Nisenson Apodized Square Aperture, and Coronagraphic masking techniques. We parameterize our results with respect to wavelength, aperture size, effects of mirror speckle, both mid- and high-spatial frequency, detector and photon noise as well pointing error. The recent numerous detections of Jupiter and Saturn like planets has driven a resurgence in research of space based high contrast imaging techniques for direct planetary imaging. Work is currently ongoing for concepts for NASA's Terrestrial Planet Finder mission and a number of study teams have been funded. The authors are members of one team.

Lyon, Richard G.↗

Image processing software for imaging spectrometry

The paper presents a software system, Spectral Analysis Manager (SPAM), which has been specifically designed and implemented to provide the exploratory analysis tools necessary for imaging spectrometer data, using only modest computational resources. The basic design objectives are described as well as the major algorithms designed or adapted for high-dimensional images. Included in a discussion of system implementation are interactive data display, statistical analysis, image segmentation and spectral matching, and mixture analysis.

Mazer, Alan S.↗

Observation of the Earth by radar

Techniques and applications of radar observation from Earth satellites are discussed. Images processing and analysis of these images are discussed. Also discussed is radar imaging from aircraft. Uses of this data include ocean wave analysis, surface water evaluation, and topographic analysis.

Elachi, C.↗

Reinventing Image Detective: An Evidence-Based Approach to Citizen Science Online

Usability studies demonstrate that web users are notoriously impatient, spending as little as 15 seconds on a home page. How do you get users to stay long enough to understand a citizen science project? How do you get users to complete complex citizen science tasks online? Image Detective, a citizen science project originally developed by scientists and science engagement specialists at the NASA Johnson Space center to engage the public in the analysis of images taken from space by astronauts to help enhance NASA's online database of astronaut imagery, partnered with the CosmoQuest citizen science platform to modernize, offering new and improved options for participation in Image Detective. The challenge: to create a web interface that builds users' skills and knowledge, creating engagement while learning complex concepts essential to the accurate completion of tasks. The project team turned to usability testing for an objective understanding of how users perceived Image Detective and the steps required to complete required tasks. A group of six users was recruited online for unmoderated and initial testing. The users followed a think-aloud protocol while attempting tasks, and were recorded on video and audio. The usability test examined users' perception of four broad areas: the purpose of and context for Image Detective; the steps required to successfully complete the analysis (differentiating images of Earth's surface from those showing outer space and identifying common surface features); locating the image center point on a map of Earth; and finally, naming geographic locations or natural events seen in the image. Usability test findings demonstrated that the following best practices can increase participation in Image Detective and can be applied to the successful implementation of any citizen science project: (1) Concise explanation of the project, its context, and its purpose; (2) Including a mention of the funding agency (in this case, NASA); (3) A preview of the specific tasks required of participants; (4) A dedicated user interface for the actual citizen science interaction. In addition, testing revealed that users may require additional context when a task is complex, difficult, or unusual (locating a specific image and its center point on a map of Earth). Video evidence will be made available with this presentation.

Romano, Cia↗

Automatic photointerpretation via texture and morphology analysis

Computer-based techniques for automatic photointerpretation based upon information derived from texture and morphology analysis of images are discussed. By automatic photointerpretation, is meant the determination of semantic descriptions of the content of the images by computer. To perform semantic analysis of morphology, a heirarchical structure of knowledge representation was developed. The simplest elements in a morphology are strokes, which are used to form alphabets. The alphabets are the elements for generating words, which are used to describe the function or property of an object or a region. The words are the elements for constructing sentences, which are used for semantic description of the content of the image. Photointerpretation based upon morphology is then augmented by textural information. Textural analysis is performed using a pixel-vector approach.

Tou, J. T.↗

Are we at a crossroads or a plateau? Radiomics and machine learning in abdominal oncology imaging

Advances in radiomics and machine learning have driven a technology boom in the automated analysis of radiology images. For the past several years, expectations have been nearly boundless for these new technologies to revolutionize radiology image analysis and interpretation. In this editorial, I compare the expectations with the realities with particular attention to applications in abdominal oncology imaging. I explore whether these technologies will leave us at a crossroads to an exciting future or to a sustained plateau and disillusionment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Astro-1 ultraviolet imaging of the 30 Doradus and SN 1987A fields with the Ultraviolet Imaging Telescope

A preliminary analysis of Ultraviolet Imaging Telescope (UIT) images in the 30 Doradus region is reported. Photometry was obtained for the 30 Doradus cluster and its UV-bright core, R136, in various UIT bandpasses. It is found that about 14 percent of the total FUV light and about 16 percent of the total near-UV light of the 3-arcmin diameter 30 Doradus cluster originates from the region within 5 arcsec of R136. The UV magnitudes and colors of R136 and other known O and Wolf-Rayet WN stars in the same field were measured. The UIT data, combined with published observations at longer wavelengths, indicate that R136a1, the brightest component of R136, is not a supermassive stars. A qualitative comparison between the UIT images, Einstein X-ray data, IRAS HiRes images, and ground-based CCD images in forbidden O III 5007 A, H-alpha, B, R, U, and Stromgren u is performed. The extended diffuse UV feature detected in the UIT images is correlated with the IR structure seen in the IRAS 60-micron HiRes image, which suggests the existence of large amounts of widely distributed dust in this region.

Cheng, Kwang-Ping↗

Preliminary analysis of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) for mineralogic mapping at sites in Nevada and Colorado

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data for sites in Nevada and Colorado were evaluated to determine their utility for mineralogical mapping in support of geologic investigations. Equal energy normalization is commonly used with imaging spectrometer data to reduce albedo effects. Spectra, profiles, and stacked, color-coded spectra were extracted from the AVIRIS data using an interactive analysis program (QLook) and these derivative data were compared to Airborne Imaging Spectrometer (AIS) results, field and laboratory spectra, and geologic maps. A feature extraction algorithm was used to extract and characterize absorption features from AVIRIS and laboratory spectra, allowing direct comparison of the position and shape of absorption features. Both muscovite and carbonate spectra were identified in the Nevada AVIRIS data by comparison with laboratory and AIS spectra, and an image was made that showed the distribution of these minerals for the entire site. Additional, distinctive spectra were located for an unknown mineral. For the two Colorado sites, the signal-to-noise problem was significantly worse and attempts to extract meaningful spectra were unsuccessful. Problems with the Colorado AVIRIS data were accentuated by the IAR reflectance technique because of moderate vegetation cover. Improved signal-to-noise and alternative calibration procedures will be required to produce satisfactory reflectance spectra from these data. Although the AVIRIS data were useful for mapping strong mineral absorption features and producing mineral maps at the Nevada site, it is clear that significant improvements to the instrument performance are required before AVIRIS will be an operational instrument.

Kruse, Fred A.↗

What can we learn from in-soil imaging of a live plant: X-ray Computed Tomography and 3D numerical simulation of root-soil system

Plant roots play a critical role in plant-soil-microbe interactions that occur in the rhizosphere, as well as processes with important implications to farming, forest management and climate change. X-ray computed tomography (XCT) has been proven to be an effective tool for non-invasive root imaging and analysis. A combination of XCT, open-source software, and our own code was used to noninvasively image a prairie dropseed (Sporobolus heterolepis) specimen, segment the root data to obtain a 3D image of the root structure at 31µm resolution, and extract quantitative information (root volume and surface area) from the 3D data, respectively. Based on the mesh generated from the root structure, computational fluid dynamics (CFD) simulations were applied to numerically investigate the root-soil-groundwater system. The plant root conductivity, soil hydraulic conductivity and transpiration rate were shown to control the groundwater distribution. The flow variability and soil water distributions under different scenarios were investigated. Parameterizations were evaluated to show their impacts on the average conductivity. The pore-scale modeling approach provides realistic simulations of rhizosphere flow processes and provides useful information that can be linked to upscaled models.

54 ENVIRONMENTAL SCIENCES↗

Detection of microcalcifications by characteristic magnetic susceptibility effects using MR phase image cross-correlation analysis

Purpose: To develop and evaluate a new method for detecting calcium deposits using their characteristic magnetic susceptibility effects on magnetic resonance (MR) images at high fields and demonstrate its potential in practice for detecting breast microcalcifications. Methods: Characteristic dipole signatures of calcium deposits were detected in magnetic resonance phase images by computing the cross-correlation between the acquired data and a library of templates containing simulated phase patterns of spherical deposits. The influence of signal-to-noise ratio and various other MR parameters on the results were assessed using simulations and validated experimentally. The method was tested experimentally for detection of calcium fragments within gel phantoms and calcium-like inhomogeneities within chicken tissue at 7 T with optimized MR acquisition parameters. The method was also evaluated for detection of simulated microcalcifications, modeled from biopsy samples of malignant breast cancer, inserted in silico into breast magnetic resonance imaging (MRIs) of healthy subjects at 7 T. For both assessments of calcium fragments in phantoms and biopsy-based simulated microcalcifications in breast MRIs, receiver operator characteristic curve analyses were performed to determine the cross-correlation index cutoff, for achieving optimal sensitivity and specificity, and the area under the curve (AUC), for measuring the method’s performance. Results: The method detected calcium fragments with sizes of 0.14–0.79 mm, 1 mm calcium-like deposits, and simulated microcalcifications with sizes of 0.4–1.0 mm in images with voxel sizes between (0.2 mm){sup 3} and (0.6 mm){sup 3}. In images acquired at 7 T with voxel sizes of (0.2 mm){sup 3}–(0.4 mm){sup 3}, calcium fragments (size 0.3–0.4 mm) were detected with a sensitivity, specificity, and AUC of 78%–90%, 51%–68%, and 0.77%–0.88%, respectively. In images acquired with a human 7 T scanner, acquisition times below 12 min, and voxel sizes of (0.4 mm){sup 3}–(0.6 mm){sup 3}, simulated microcalcifications with sizes of 0.6–1.0 mm were detected with a sensitivity, specificity, and AUC of 75%–87%, 54%–87%, and 0.76%–0.90%, respectively. However, different microcalcification shapes were indistinguishable. Conclusions: The new method is promising for detecting relatively large microcalcifications (i.e., 0.6–0.9 mm) within the breast at 7 T in reasonable times. Detection of smaller deposits at high field may be possible with higher spatial resolution, but such images require relatively long scan times. Although mammography can detect and distinguish the shape of smaller microcalcifications with superior sensitivity and specificity, this alternative method does not expose tissue to ionizing radiation, is not affected by breast density, and can be combined with other MRI methods (e.g., dynamic contrast-enhanced MRI and diffusion weighted MRI), to potentially improve diagnostic performance.

60 APPLIED LIFE SCIENCES↗

2-D nonlinear IIR-filters for image processing - An exploratory analysis

A new nonlinear IIR filter structure is introduced and its deterministic properties are analyzed. It is shown to be better suited for image processing applications than its linear shift-invariant counterpart. The new structure is obtained from causality inversion of a 2D quarterplane causal linear filter with respect to the two directions of propagation. It is demonstrated, that by using this design, a nonlinear 2D lowpass filter can be constructed, which is capable of effectively suppressing Gaussian or impulse noise without destroying important image information.

Bauer, P. H.↗