Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTEGRAL DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Million Worker Study

Radiation health issues have been an important aspect of DOE's Worker Safety and Health programs. The goal is to ensure that workers are adequately protected from the various radiological hazards associated with DOE sites and operations. Since the early 1940’s DOE has supported the conduct of epidemiologic studies of practically every DOE (AEC) facility and collected these data, now managed by the Oak Ridge Associated Universities (ORAU), in remarkable detail. In the early 2000s, the Office of Health, Safety and Security authorized access to specific DOE worker datasets. Shortly thereafter, the DOE Office of Science provided funds for a pilot study that confirmed the feasibility of the Million Worker Study (MWS), and then additional resources were provided (with other agencies) to extend the follow-up of many populations, not just DOE workers, but also atomic veterans, industrial radiographers, nuclear power plant workers and medical radiation workers (the Million Persons Study (MPS)). This proposal was a continuation of support provided by DOE, specifically to extend the follow-up of the worker populations at the Mallinckrodt Chemical Works (MCW) and Los Alamos National Laboratory (LANL). The work addresses DOE’s interest in clarifying the health risks of their workers as well as contributing knowledge on radiation risks that is relevant today with regard to compensation schemes. The findings are also important for the US public in light of the increased population exposure to medical imaging, environmental circumstances such as hydraulic fracturing, increased exposures during high altitude flights, and with regard to nuclear accidents such as Fukushima and possible terrorist events. Furthermore, it is important to consider reducing the uncertainty in current risk estimates by developing risk coefficients based on healthy American workers who are more representative of U.S. workers and the general public than 1945 Japanese survivors of the atomic bombs living in a war-torn country which experienced deprivation, malnourishment, and increased rates of infections and other diseases. But more importantly, it is important to learn whether radiation exposures received gradually over time (e.g., years) are more or less effective in causing health effects, cancer in particular, than if the radiation dose is received all at once in a fraction of a second as experienced by the Japanese atomic bomb survivors. Finally, the ability to evaluate and combine large populations with intakes of radionuclides such as uranium, radium, plutonium, americium and polonium will provide new quantitative knowledge on human health effects that hitherto has not been possible. This cost-efficient study has built on the investments made and foundations laid by investigators and government agencies, including DOE, over the past 30-40 years, which have established early worker cohorts that can now provide answers to questions on the lifetime human health risks associated with low-level radiation exposures. Collaborating institutions included: International Epidemiology Institute, Oak Ridge Associated Universities, Oak Ridge National Laboratory, Los Alamos National Laboratory, Landauer, Inc., and Vanderbilt University. Follow-up of these two populations and the integration of them with the many other cohorts (now a total of 31) in the MPS continues under a separate DOE grant (DE-AU0000046).

61 RADIATION PROTECTION AND DOSIMETRY↗

DEHBA (di-2-ethylhexylbutyramide) gamma radiolysis under spent nuclear fuel solvent extraction process conditions

Di-2-ethylhexylbutyramide (DEHBA) has been presented as part of a hydro-reprocessing solvent extraction system for the co-extraction of uranium and plutonium from spent nuclear fuel. Yet, there remains a lack of quantitative understanding of the impact of chemical environment on the radiation chemistry of DEHBA, especially under conditions expected in real-world solvent extraction processes. Therefore, we have undertaken a systematic investigation into the radiolytic degradation of DEHBA in n-dodecane under fully aerated and biphasic conditions. DEHBA integrity and degradation product formation were measured for both extraction (in contact with 4.0 M HNO 3(aq) ) and stripping (in contact with 0.1 M HNO 3(aq) ) formulations. At the lower acidity the rate of DEHBA/n-dodecane degradation was slow (G = -0.26 ± 0.02 µM J -1 ) whereas at the higher acidity this degradation was about 35% faster (G = -0.35 ± 0.02 µM J-1). Both values were much less than analogous measurements under deaerated conditions. Under continuously aerated conditions, FTIR and ESI-MS measurements identified the two major degradation products, bis-2-ethylhexylamine (b2EHA) and N-(2-ethylhexyl)butyramide (MEHBA), as well as the presence of additional oxidized product species. Solvent system performance was also investigated using uranium extraction and strip distribution ratio measurements. These reports showed that there was only minimal change in uranium extraction and stripping performance with absorbed gamma dose.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Additively manufactured refractory high-entropy alloys with superior radiation resistance

Refractory high-entropy alloys (RHEAs) are promising candidates for next-generation nuclear and high-temperature applications. Among many approaches to manufacture RHEAs, additive manufacturing (AM) represents the most recent and advanced metal manufacturing method which allows near-net-shape manufacturing to reduce material waste and post-processing time. However, performance of AM RHEAs under complex irradiation conditions remains largely unexplored. Here, in this study, we demonstrate for the first time the response of directed energy deposition (DED) AM quaternary RHEAs (HfTaVW, CrTaVW) subjected to sequential dual-beam ion irradiation, consisting of helium pre-implantation followed by high-dose heavy ion bombardment. Compositions of DED AM RHEAs were selected using Monte Carlo (MC) simulations based on a cluster expansion (CE) Hamiltonian parameterized by density functional theory (DFT). Post-irradiation microstructural characterization revealed that the AM RHEA maintained remarkable stability, with suppressed helium bubble growth and reduced defect accumulation compared to conventional alloys. Even at high doses (∼100 dpa), the alloy exhibited no void swelling, a low density of dislocation loops, and no evidence of severe degradation. These results highlight the intrinsic ability of AM-derived microstructures and multicomponent chemistry to synergistically mitigate irradiation effects. Our findings establish AM RHEAs as a class of materials with superior resistance to radiation damage under conditions relevant to advanced fusion and fission environments and demonstrate the importance of sequential ion beam studies in evaluating their long-term performance.

36 MATERIALS SCIENCE↗

Alpha Radiation Effects on Silicon Oxynitride Waveguides

Photonic technologies are today of great interest for use in harsh environments, such as outer space, where they can potentially replace current communication systems based on radiofrequency components. However, very much alike to electronic devices, the behavior of optical materials and circuits can be strongly altered by high-energy and high-dose ionizing radiations. Here, we investigate the effects of alpha () radiation with MeV-range energy on silicon oxynitride (SiON) optical waveguides. Irradiation with a dose of 5×1015 cm-2 increases the refractive index of the SiON core by nearly 10-2, twice as much that of the surrounding silica cladding, leading to a significant increase of the refractive index contrast of the waveguide. The higher mode confinement induced by -radiation reduces the loss of tightly bent waveguides. We show that this increases the quality factor of microring resonators by 20%, with values larger than 105 after irradiation.

alpha particles↗

SU-F-BRD-10: Improving Plan Delivery Efficiency of Intensity Modulated Proton Plans with Prioritized Optimization

Purpose: To integrate treatment delivery time into plan optimization in spot scanning intensity modulated proton therapy. Utilizing a dedicated research treatment planning system we present an optimization approach to explore the trade-off between the correlated parameters treatment time and plan quality on an astrocytoma patient case. Methods: The planning system is based on prioritized optimization, a stepwise approach of implementing clinical goals. After each optimization step, dosimetric achievements are turned into hard constraints to maintain the achieved plan quality. Prior achievements can be violated by a so-called slip-factor which allows to study possible trade-offs of conflicting goals. Plan quality is obtained in the first two steps, while the third step optimizes delivery efficiency by working on the spot weight distribution via four alternative Methods: elimination of low weighted spots (1), elimination of spots hardly contributing to PTV dose, followed by reoptimization of the resulting smaller optimization problem (2), reduction of spot weights variance within each energy layer (3), and reduction of the overall spot weight sum (4). Treatment times were calculated assuming either constant or variable beam current depending on the lowest spot weight. Results: Delivery efficiency can be improved remarkably without influencing the plan quality. Absolute time savings depend on the utilized method and facility properties. By varying slip-factor and spot reduction limits, a border of worsening quality is detectable for all methods.Deleting low weighted spots by 10% results in a noticeable decrease in minimum target dose. Further reduction results in more heterogeneous dose distributions and insufficient coverage. Option 2 showed constant plan quality for spot reductions of more than 10%. Conclusion: Including treatment time optimization as a final step into prioritized optimization allows for more efficient treatment plans by redistributing the spot patterns without compromising plan quality, which has to remain the main intent of radiotherapy treatment. The authors report grants from German Research Foundation (DFG) during the conduct of the study.

60 APPLIED LIFE SCIENCES↗

SU-F-T-160: Commissioning of a Single-Room Double-Scattering Proton Therapy System

Purpose: To report the detailed commissioning experience for a compact double-scattering Mevion S250 proton therapy system at a University Cancer Center site. Methods: The commissioning of the proton therapy system mainly consisted of ensuring integrity of mechanical and imaging system, beam data collection, and commissioning of a treatment planning system (TPS). First, mechanical alignment and imaging were tested including safety, interlocks, positional accuracy of couch and gantry, image quality, mechanical and imaging isocenter and so on. Second, extensive beam data (outputs, PDDs, and profiles) were collected and analyzed through effective sampling of range (R) and modulation width (M) from 24 beam options. Three different output (cGy/MU) prediction models were also commissioned as primary and secondary MU calculation tool. Third, the Varian Eclipse TPS was commissioned through five sets of data collections (in-water Bragg peak scans, in-air longitudinal fluence scans, in-air lateral profiles, in-air half-beam profiles, and an HU-to-stopping-power conversion curve) and accuracy of TPS calculation was tested using in-water scans and dose measurements with a 2D array detector with block and range compensator. Finally, an anthropomorphic phantom was scanned and heterogeneity effects were tested by inserting radiochromic films in the phantom and PET activation scans for range verification in conjunction with end-to-end test. Results: Beam characteristics agreed well with the vendor specifications; however, minor mismatches in R and M were found in some measurements during the beam data collection. These were reflected into the TPS commissioning such that the TPS could accurately predict the R and M within tolerance levels. The output models had a good agreement with measured outputs (<3% error). The end-to-end test using the film and PET showed reasonably the TPS predicted dose, R and M in heterogeneous medium. Conclusion: The proton therapy system was successfully commissioned and was released for clinical use.

60 APPLIED LIFE SCIENCES↗

Education and training in the field of nuclear instrumentation and measurement: CEA/INSTN (National Institute for Nuclear Sciences and Technologies) strategy to improve and develop new pedagogical tools and methods

Part of the French Alternative Energies and Atomic Energy Commission (CEA), the National Institute for Nuclear Science and Technology (INSTN) is a higher education institution whose mission is to provide students and professionals a high level of scientific and technological qualification in all disciplines related to nuclear energy applications. In this frame, INSTN carries out education and training (E and T) programs in nuclear instrumentation and radioprotection. Its strategy has always been to complete theoretical courses by training courses and laboratory works carried out on an extensive range of training tools that includes a large panel of nuclear instrumentation as well as software applications. Since its creation in 1956, the INSTN has conducted both education and vocational programs on ionizing radiation detection. An extensive range of techniques have commonly been used during practical works with students and employees of companies who need to get the knowledge and specialization in this field. Today, the INSTN is mainly equipped with usual detectors and electronics in large numbers in order to be able to accommodate up to 48 trainees at the same time in two classrooms, with only two trainees for one workstation in order to optimize their learning. In the field of the neutron detection systems, the INSTN has strongly developed its offer taking advantage of the use of research reactors, such as ISIS reactor (700 kW) at Saclay. The implementation of neutron detection systems specific to the courses offers a unique way of observing and analysing the signal coming from neutron detectors, as well as learning how to set the parameters of the detection system in real conditions. Providing the trainees with an extensive overview of each part of the neutron monitoring instrumentation apply to a nuclear reactor, hands-on measurements on the ISIS reactor play a major role in ensuring a practical and comprehensive understanding of the neutron detection system and their integration in the safety system of nuclear reactors. It also gives a solid background for the follow up and the development of the neutron detection systems. Another field of activity of the INSTN is the development of new teaching tools using software applications. We describe hereafter two applications that have recently been developed by the institute, O.S.I.R.I.S and DOSIMEX. The INSTN and the company OREKA have developed an innovative teaching tool named O.S.I.R.I.S. The tool is built on a virtual 3D environment in which users operate in a totally free way. The action is located in a pressurised water reactor in the environment of a steam generator building. The users are students or professionals who want to learn and train on concrete situations on how to protect the workers against radiation. Through the use of this serious game, users must: establish a predictive dose evaluation, implement the principles of radiation protection, perform the dose result of the operation, analyse the gap between the predictive collective dose and the collective dose achieved, and decide about the lessons to provide feedback. Taking into account the increasing constraints related to radiation protection, it is essential to use computer codes to evaluate the dose rates generated by sources of ionizing radiation. Many powerful codes exist but are often relatively complex to implement and are dedicated to experts. In addition, these codes are often 'black boxes' that does not allow the user to understand the underlying physics. The objective of DOSIMEX codes developed by the INSTN is to give, by the means of a VBA code with a simple interface, the ability to easily conduct a wide range of radiological exposure situations: calculation of gamma, beta, neutron equivalent dose rate, calculation of internal contamination and atmospheric transfer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Involvement of Mst1 in tumor necrosis factor-{alpha}-induced apoptosis of endothelial cells

Mammalian sterile 20-kinase 1 (Mst1), a member of the sterile-20 family protein kinase, plays an important role in the induction of apoptosis. However, little is know about the physiological activator of Mst1 and the role of Mst1 in endothelial cells (ECs). We examined whether Mst1 is involved in the tumor necrosis factor (TNF)-{alpha}-induced apoptosis of ECs. Western blot analysis revealed that TNF-{alpha} induced activation of caspase 3 and Mst1 in a time- and dose-dependent manner. TNF-{alpha}-induced Mst1 activation is almost completely prevented by pretreatment with Z-DEVD-FMK, a caspase 3 inhibitor. Nuclear staining with Hoechst 33258 and fluorescence-activated cell sorting of propidium iodide-stained cells showed that TNF-{alpha} induced apoptosis of EC. Diphenyleneiodonium, an inhibitor of NADPH oxidase, and N-acetylcysteine, a potent antioxidant, also inhibited TNF-{alpha}-induced activation of Mst1 and caspase 3, as well as apoptosis. Knockdown of Mst1 expression by short interfering RNA attenuated TNF-{alpha}-induced apoptosis but not cleavage of caspase 3. These results suggest that Mst1 plays an important role in the induction of TNF-{alpha}-induced apoptosis of EC. However, positive feedback mechanism between Mst1 and caspase 3, which was shown in the previous studies, was not observed. Inhibition of Mst1 function may be beneficial for maintaining the endothelial integrity and inhibition of atherogenesis.

60 APPLIED LIFE SCIENCES↗

Development of an updated PBPK model for trichloroethylene and metabolites in mice, and its application to discern the role of oxidative metabolism in TCE-induced hepatomegaly

Trichloroethylene (TCE) is a lipophilic solvent rapidly absorbed and metabolized via oxidation and conjugation to a variety of metabolites that cause toxicity to several internal targets. Increases in liver weight (hepatomegaly) have been reported to occur quickly in rodents after TCE exposure, with liver tumor induction reported in mice after long-term exposure. An integrated dataset for gavage and inhalation TCE exposure and oral data for exposure to two of its oxidative metabolites (TCA and DCA) was used, in combination with an updated and more accurate physiologically-based pharmacokinetic (PBPK) model, to examine the question as to whether the presence of TCA in the liver is responsible for TCE-induced hepatomegaly in mice. The updated PBPK model was used to help discern the quantitative contribution of metabolites to this effect. The update of the model was based on a detailed evaluation of predictions from previously published models and additional preliminary analyses based on gas uptake inhalation data in mice. The parameters of the updated model were calibrated using Bayesian methods with an expanded pharmacokinetic database consisting of oral, inhalation, and iv studies of TCE administration as well as studies of TCE metabolites in mice. The dose-response relationships for hepatomegaly derived from the multi-study database showed that the proportionality of dose to response for TCE- and DCA-induced hepatomegaly is not observed for administered doses of TCA in the studied range. The updated PBPK model was used to make a quantitative comparison of internal dose of metabolized and administered TCA. While the internal dose of TCA predicted by modeling of TCE exposure (i.e., mg TCA/kg-d) showed a linear relationship with hepatomegaly, the slope of the relationship was much greater than that for directly administered TCA. Thus, the degree of hepatomegaly induced per unit of TCA produced through TCE oxidation is greater than that expected per unit of TCA administered directly, which is inconsistent with the hypothesis that TCA alone accounts for TCE-induced hepatomegaly. In addition, TCE-induced hepatomegaly showed a much more consistent relationship with PBPK model predictions of total oxidative metabolism than with predictions of TCE area-under-the-curve in blood, consistent with toxicity being induced by oxidative metabolites rather than the parent compound. Therefore, these results strongly suggest that oxidative metabolites in addition to TCA are necessary contributors to TCE-induced liver weight changes in mice.

60 APPLIED LIFE SCIENCES↗

Crack Growth Rate and Fracture Toughness of Stainless Steel Welds in Light Water Reactor Environment

Austenitic stainless steel welds play a crucial role in maintaining the structural integrity of light water reactors. Within the reactor core, stainless steel welds endure a harsh service environment including elevated temperature, corrosive coolant, and intense neutron irradiation. Long-term exposure to such a severe service environment could lead to performance degradation. To ensure the safe and economic operation of light water reactors, this study performed crack growth rate and fracture toughness tests on irradiated and thermally aged weld samples harvested from decommissioned reactor components. In a low-corrosion-potential environment, stainless steel welds showed resistance to stress corrosion cracking, and the measured crack propagation rates were comparable to those of wrought stainless steels under similar test conditions. However, a marked decline in fracture toughness was observed in weld samples, particularly in irradiated samples. Fracture instability was observed at ~0.8 dpa, significantly lower than those observed in wrought stainless steels. Further research at higher doses is needed to evaluate the dose dependence of irradiation-induced embrittlement, and to understand the interplay between thermal aging and neutron irradiation in stainless steel welds.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PON1Q192R genetic polymorphism modifies organophosphorous pesticide effects on semen quality and DNA integrity in agricultural workers from southern Mexico

Pesticide exposure, including organophosphorous (OP) insecticides, has been associated with poor semen quality, and paraoxonase (PON1), an enzyme involved in OP deactivation, may have a role on their susceptibility, due to PON1 polymorphisms. Our objective was to evaluate the role of PON1Q192R polymorphism on the susceptibility to OP toxicity on semen quality and DNA integrity in agricultural workers. A cross-sectional study was conducted in farmers with Mayan ascendancy from southeastern Mexico chronically exposed to pesticides; mostly OP. Fifty four agricultural workers (18-55 years old) were included, who provided semen and blood samples. Semen quality was evaluated according to WHO, sperm DNA damage by in situ-nick translation (NT-positive cells), PON1Q192R polymorphism by real-time PCR and serum PON1 activity by using phenylacetate and paraoxon. Two OP exposure indexes were created: at the month of sampling and during 3 months before sampling, representing the exposure to spermatids-spermatozoa and to cells at one spermatogenic cycle, respectively. PON1 192R and 192Q allele frequencies were 0.54 and 0.46, respectively. Significant associations were found between OP exposure at the month of sampling and NT-positive cells and sperm viability in homozygote 192RR subjects, and dose-effect relationships were observed between OP exposure during 3 months before sampling and sperm quality parameters and NT-positive cells in homozygote 192RR farmers. This suggests that cells at all stages of spermatogenesis are target of OP, and that there exists an interaction between OP exposure and PON1Q192R polymorphism on these effects; farmers featuring the 192RR genotype were more susceptible to develop reproductive toxic effects by OP exposure.

60 APPLIED LIFE SCIENCES↗

Radiological Releases from Novel Fuel Forms in Advanced Reactors During Severe Accidents for Consequence Analyses

Various advanced reactor developers are exploring the potential for reductions in the size of physical security forces and emergency planning zones. These reductions are based on robust fuel forms and inherently safe reactor designs. However, such reductions in physical protection measures could increase the risk of sabotage. To assess the possibility of reducing these measures, sabotage-induced radiological consequence analyses were carried out. These analyses considered accident scenarios that were beyond design basis accidents and overly conservative (Shah, 2025a; Shah, 2025b; Shah and Hartanto, 2026), yielding very large release fractions. These fractions, which can be used to evaluate physical protection and emergency planning requirements, have been crudely determined and applied as demonstrations for a sodium-cooled fast reactor (SFR) (Shah and Hartanto, 2025a), a high-temperature gas-cooled reactor (HTGR) (Shah and Hartanto, 2025b), a heat pipe–cooled reactor (HPR) (Shah and Hartanto, 2025c), and a molten salt–cooled reactor (MSR) (Shah et al., 2026). A Sandia National Laboratories (SNL) team used MELCOR—a fully integrated severe accident analysis code—to demonstrate the code’s capability to analyze advanced (i.e., not light water–cooled) reactors (including a fluoride salt–cooled high-temperature reactor [FHR]) and calculate radiological releases to the environment during severe accidents (Wagner et al., 2022a, 2022b, 2022c, 2023a, and 2023b). Although the analyses were carried out to demonstrate MELCOR’s growing capability, the release source terms were estimated for advanced reactors, providing valuable insights into the accident progression and radiological releases. These findings from prior SNL studies, including estimated source terms and related sensitivity studies, were leveraged to derive source terms for postulated sabotage-induced accidents. Insights from these sensitivity studies informed the scaling of SNL’s estimated source terms for the defined accident scenarios. The derived release fractions for the severe accident scenarios for the respective reactor designs can be used to perform more nuanced dose consequence analyses to evaluate the reactors’ physical protection and emergency planning zone requirements. These analyses are in accordance with the risk-informed, performance-based approach proposed under 10 CFR Part 53. This study builds on the prior source term analyses and associated sensitivity studies by SNL to derive time-dependent and design-informed release fractions. Section 2 describes the diverse advanced reactor designs analyzed by the SNL team. Section 3 discusses the severe accident analyses, the release fractions calculated, and the limitations and assumptions of the demonstration project. Section 4 presents the release percentages derived for the hypothetical sabotage-induced severe accidents at the advanced reactors. Section 5 summarizes the study’s findings and conclusions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Telerobotic system concept for real-time soft-tissue imaging during radiotherapy beam delivery

Purpose: The curative potential of external beam radiation therapy is critically dependent on having the ability to accurately aim radiation beams at intended targets while avoiding surrounding healthy tissues. However, existing technologies are incapable of real-time, volumetric, soft-tissue imaging during radiation beam delivery, when accurate target tracking is most critical. The authors address this challenge in the development and evaluation of a novel, minimally interfering, telerobotic ultrasound (U.S.) imaging system that can be integrated with existing medical linear accelerators (LINACs) for therapy guidance. Methods: A customized human-safe robotic manipulator was designed and built to control the pressure and pitch of an abdominal U.S. transducer while avoiding LINAC gantry collisions. A haptic device was integrated to remotely control the robotic manipulator motion and U.S. image acquisition outside the LINAC room. The ability of the system to continuously maintain high quality prostate images was evaluated in volunteers over extended time periods. Treatment feasibility was assessed by comparing a clinically deployed prostate treatment plan to an alternative plan in which beam directions were restricted to sectors that did not interfere with the transabdominal U.S. transducer. To demonstrate imaging capability concurrent with delivery, robot performance and U.S. target tracking in a phantom were tested with a 15 MV radiation beam active. Results: Remote image acquisition and maintenance of image quality with the haptic interface was successfully demonstrated over 10 min periods in representative treatment setups of volunteers. Furthermore, the robot's ability to maintain a constant probe force and desired pitch angle was unaffected by the LINAC beam. For a representative prostate patient, the dose-volume histogram (DVH) for a plan with restricted sectors remained virtually identical to the DVH of a clinically deployed plan. With reduced margins, as would be enabled by real-time imaging, gross tumor volume coverage was identical while notable reductions of bladder and rectal volumes exposed to large doses were possible. The quality of U.S. images obtained during beam operation was not appreciably degraded by radiofrequency interference and 2D tracking of a phantom object in U.S. images obtained with the beam on/off yielded no significant differences. Conclusions: Remotely controlled robotic U.S. imaging is feasible in the radiotherapy environment and for the first time may offer real-time volumetric soft-tissue guidance concurrent with radiotherapy delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Design Tools to Assess Hydro-Turbine Biological Performance: Priest Rapids Dam Turbine Replacement Project

Over the past two decades, there have been many studies describing injury mechanisms associated with turbine passage, the response of various fish species to these mechanisms, and the probability of survival through dams. Although developing tools to design turbines that improve passage survival has been difficult and slow, a more robust quantification of the turbine environment has emerged through integrating physical model data, fish survival data, and computational fluid dynamics (CFD) studies. Grant County Public Utility District (GCPUD) operates the Priest Rapids Dam (PRD), a hydroelectric facility on the Columbia River in Washington State. The dam contains 10 Kaplan-type turbine units that are now almost 50 years old. The Utility District plans to refit all of these aging turbines with new turbines. The Columbia River at PRD is a migratory pathway for several species of juvenile and adult salmonids, so passage of fish through the dam is a major consideration when replacing the turbines. In this presentation, a method for turbine biological performance assessment (BioPA) is introduced. Using this method, a suite of biological performance indicators is computed based on simulated data from a CFD model of a proposed turbine design. Each performance indicator is a measure of the probability of exposure to a certain dose of an injury mechanism. Using known relationships between the dose of an injury mechanism and frequency of injury (dose–response) from laboratory or field studies, the likelihood of fish injury for a turbine design can be computed from the performance indicator. By comparing the values of the indicators from proposed designs, the engineer can identify the more-promising alternatives. We will present application of the BioPA method for baseline risk assessment calculations for the existing Kaplan turbines at PRD that will be used as the minimum biological performance that a proposed new design must achieve.

CFD↗

L2-Charged Particle Environment (L2-CPE)Low Energy Radiation Fluence Model

The L2 Charged Particle Environment (L2-CPE) model provides estimates of number flux and fluence for the low energy electron, proton, and alpha particle populations in the near Earth solar wind and the Earth’s distant magnetosheath and magnetotail. The model is an engineering tool for specifying radiation environments over an energy range from a few eV to a few MeV of importance to surface dose and radiation damage to thin space exposed materials and is intended for use in space system design applications. Mission fluences are obtained by simulating a spacecraft flight trajectory through time-dependent bow shock and magnetopause boundaries with dimensions and orientations driven by solar wind parameters. Monte Carlo sampling of flux environments within individual plasma regimes and/or fluence accumulated along a fight trajectory through multiple regimes is used to determine statistical variations (means and extremes) of the differential number flux and fluence environments for each of the three charged particle species. Model output is differential (in energy) number fluence and flux for the three particle species in units of particles/cm2-keV and particles/cm2-sec-keV, respectively. Users can select the energy range of interest but the current version of the code (L2-CPE Version 1.4.2d) is limited to an energy range of 1 eV to 10 MeV. Flux is integrated over angle to give flux and fluence to surfaces in the ±XGSE, ±YGSE, and/or ±ZGSE directions. Figure 1 shows the opening screen from the L2-CPE graphical user interface (GUI) with options for flux, fluence, plotting model output. The flux scene generate is not currently implemented in the GUI.

Joseph I Minow↗

Integrated Experimental and Model-based Analysis Reveals the Spatial Aspects of EGFR Activation Dynamics

The epidermal growth factor receptor (EGFR) belongs to the ErbB family of receptor tyrosine kinases, and controls a diverse set of cellular responses relevant to development and tumorigenesis. ErbB activation is a complex process involving receptor-ligand binding, receptor dimerization, phosphorylation, and trafficking (internalization, recycling and degradation), which together dictate the spatio-temporal distribution of active receptors within the cell. The ability to predict this distribution, and elucidation of the factors regulating it, would help to establish a mechanistic link between ErbB expression levels and the cellular response. Towards this end, we constructed mathematical models for deconvolving the contributions of receptor dimerization and phosphorylation to EGFR activation, and to examine the dependence of these processes on sub-cellular location. We collected experimental datasets for EGFR activation dynamics in human mammary epithelial cells, with the specific goal of model parameterization, and used the data to estimate parameters for several alternate models. Model-based analysis indicated that: 1) signal termination via receptor dephosphorylation in late endosomes, prior to degradation, is an important component of the response, 2) less than 40% of the receptors in the cell are phosphorylated at any given time, even at saturating ligand doses, and 3) receptor dephosphorylation rates at the cell surface and early endosomes are comparable. We validated the last finding by measuring EGFR dephosphorylation rates at various times following ligand addition both in whole cells, and in endosomes using ELISAs and fluorescent imaging. Overall, our results provide important information on how EGFR phosphorylation levels are regulated within cells. Further, the mathematical model described here can be extended to determine receptor dimer abundances in cells co-expressing various levels of ErbB receptors. This study demonstrates that an iterative cycle of experiments and modeling can be used to gain mechanistic insight regarding complex cell signaling networks.

kinetic modeling↗

Daily Bone Alignment With Limited Repeat CT Correction Rivals Daily Ultrasound Alignment for Prostate Radiotherapy

Purpose: To compare the effectiveness of daily ultrasound (US)- and computed tomography (CT)-guided alignments with an off-line correction protocol using daily bone alignment plus a correction factor for systematic internal prostate displacement (CF{sub ID}). Methods and Materials: Ten prostate cancer patients underwent CT scans three times weekly using an integrated CT-linear accelerator system, followed by alignment using US for daily radiotherapy. Intensity-modulated radiotherapy plans were designed with our current clinical margins. The treatment plan was copied onto the repeat CT images and aligned using several methods: (1) bone alignment plus CF{sub ID} after three off-line CT scans (bone+3CT), (2) bone alignment plus CF{sub ID} after six off-line CT scans (bone+6CT), (3) US alignment, and (4) CT alignment. The accuracy of the repeated US and CT measurements to determine the CF{sub ID} was compared. The target dosimetric effect was quantified. Results: The CF{sub ID} for internal systematic prostate displacements was more accurately measured with limited repeat CT scans than with US (residual error, 0.0 {+-} 0.7 mm vs. 2.0 {+-} 3.2 mm). Bone+3CT, bone+6CT, and US provided equivalent prostate and seminal vesicle dose coverage, but bone+3CT and bone+6CT produced more precise daily alignments. Daily CT alignment provided the greatest target dose coverage. Conclusion: Daily bone alignment plus CF{sub ID} for internal systematic prostate displacement provided better daily alignment precision and equivalent dose coverage compared with daily US alignment. The CF{sub ID} should be based on at least three repeat CT scans, which could be collected before the start of treatment or during the first 3 treatment days. Daily bone alignment plus CF{sub ID} provides another option for accurate prostate cancer patient positioning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of chemical environment on the radiation chemistry of N , N -di-(2-ethylhexyl)butyramide (DEHBA) and plutonium retention

N,N-di-(2-ethylhexyl)butyramide (DEHBA) has been proposed as part of a hydro-reprocessing solvent extraction system for the co-extraction of uranium and plutonium from spent nuclear fuel, owing to its selectivity for hexavalent uranium and tetravalent plutonium. However, there is a critical lack of quantitative understanding regarding the impact of chemical environment on the radiation chemistry of DEHBA, and how this would affect process performance. Here we present a systematic investigation into the radiolytic degradation of DEHBA in a range of n-dodecane solvent system formulations, where we subject DEHBA to gamma irradiation, measure reaction kinetics, ligand integrity, degradation product formation, and investigate solvent system performance through uranium and plutonium extraction and strip distribution ratios. The rate of DEHBA degradation in n-dodecane was found to be slow (G = -0.31 ± 0.02 μmol J -1 ) but enhanced upon contact with the oxidizing conditions of the investigated solvent systems (organic-only, or in contact with either 0.1 or 3.0 M aqueous nitric acid). Two major degradation products were identified in the organic phase, bis-2-ethylhexylamine (b2EHA) and N-(2-ethylhexyl)butyramide (MEHBA), resulting from the cleavage of C–N bonds, and could account for the total loss of DEHBA up to ~300 kGy for organic-only conditions. Both b2EHA and MEHBA were also found to be susceptible to radiolytic degradation, having G-values of -0.12 ± 0.01 and -0.08 ± 0.01 μmol J -1 , respectively. Solvent extraction studies showed: (i) negligible change in uranium extraction and stripping with increasing absorbed dose; and (ii) plutonium extraction and retention exhibits complex dependencies on absorbed dose and chemical environment. Organic-only conditions afforded enhanced plutonium extraction and retention attributed to b2EHA, while acid contacts inhibited this effect and promoted significant plutonium retention for the highest acidity. Overall it has been demonstrated that chemical environment during irradiation has a significant influence on the extent of DEHBA degradation and plutonium retention.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗