Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Homogenization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Dosimetric Comparison of Intensity-Modulated Stereotactic Radiotherapy With Other Stereotactic Techniques for Locally Recurrent Nasopharyngeal Carcinoma

Purpose: Locally recurrent nasopharyngeal carcinoma (NPC) patients can be salvaged by reirradiation with a substantial degree of radiation-related complications. Stereotactic radiotherapy (SRT) is widely used in this regard because of its rapid dose falloff and high geometric precision. The aim of this study was to examine whether the newly developed intensity-modulated stereotactic radiotherapy (IMSRT) has any dosimetric advantages over three other stereotactic techniques, including circular arc (CARC), static conformal beam (SmMLC), and dynamic conformal arc (mARC), in treating locally recurrent NPC. Methods and Materials: Computed tomography images of 32 patients with locally recurrent NPC, previously treated with SRT, were retrieved from the stereotactic planning system for contouring and computing treatment plans. Treatment planning of each patient was performed for the four treatment techniques: CARC, SmMLC, mARC, and IMSRT. The conformity index (CI) and homogeneity index (HI) of the planning target volume (PTV) and doses to the organs at risk (OARs) and normal tissue were compared. Results: All four techniques delivered adequate doses to the PTV. IMSRT, SmMLC, and mARC delivered reasonably conformal and homogenous dose to the PTV (CI <1.47, HI <0.53), but not for CARC (p < 0.05). IMSRT presented with the smallest CI (1.37) and HI (0.40). Among the four techniques, IMSRT spared the greatest number of OARs, namely brainstem, temporal lobes, optic chiasm, and optic nerve, and had the smallest normal tissue volume in the low-dose region. Conclusion: Based on the dosimetric comparison, IMSRT was optimal for locally recurrent NPC by delivering a conformal and homogenous dose to the PTV while sparing OARs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton Therapy for Malignant Pleural Mesothelioma After Extrapleural Pleuropneumonectomy

Purpose: To perform comparative planning for intensity-modulated radiotherapy (IMRT) and proton therapy (PT) for malignant pleural mesothelioma after radical surgery. Methods and Materials: Eight patients treated with IMRT after extrapleural pleuropneumonectomy (EPP) were replanned for PT, comparing dose homogeneity, target volume coverage, and mean and maximal dose to organs at risk. Feasibility of PT was evaluated regarding the dose distribution with respect to air cavities after EPP. Results: Dose coverage and dose homogeneity of the planning target volume (PTV) were significantly better for PT than for IMRT regarding the volume covered by >95% (V95) for the high-dose PTV. The mean dose to the contralateral kidney, ipsilateral kidney, contralateral lung, liver, and heart and spinal cord dose were significantly reduced with PT compared with IMRT. After EPP, air cavities were common (range, 0-850 cm{sup 3}), decreasing from 0 to 18.5 cm{sup 3}/day. In 2 patients, air cavity changes during RT decreased the generalized equivalent uniform dose (gEUD) in the case of using an a value of < - 10 to the PTV2 to <2 Gy in the presence of changing cavities for PT, and to 40 Gy for IMRT. Small changes were observed for gEUD of PTV1 because PTV1 was reached by the beams before air. Conclusion: Both PT and IMRT achieved good target coverage and dose homogeneity. Proton therapy accomplished additional dose sparing of most organs at risk compared with IMRT. Proton therapy dose distributions were more susceptible to changing air cavities, emphasizing the need for adaptive RT and replanning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical Tomotherapy Versus Conventional Intensity-Modulated Radiation Therapy for Primary Chemoradiation in Cervical Cancer Patients: An Intraindividual Comparison

Purpose: To compare intensity-modulated radiotherapy (IMRT) delivered by helical tomotherapy (HT) with conventional IMRT for primary chemoradiation in cervical cancer patients. Methods and Materials: Twenty cervical cancer patients undergoing primary chemoradiation received radiation with HT; 10 patients underwent pelvic irradiation (PEL) and 10 extended-field irradiation (EXT). For treatment planning, the simultaneously integrated boost (SIB) concept was applied. Tumor, pelvic, with or without para-aortic lymph nodes were defined as planning target volume A (PTV-A) with a prescribed dose of 1.8/50.4 Gy (28 fractions). The SIB dose for the parametrium (PTV-B), was 2.12/59.36 Gy. The lower target constraints were 95% of the prescribed dose in 95% of the target volume, and the upper dose constraint was 107%. The irradiated small-bowel volumes were kept as low as possible. For every HT plan, a conventional IMRT plan was calculated and compared with regard to dose-volume histogram, conformity index and conformity number, and homogeneity index. Results: Both techniques allowed excellent target volume coverage and sufficient SB sparing. Conformity index and conformity number results for both PTV-A and PTV-B, homogeneity index for PTV-B, and SB sparing for V45, V50, Dmax, and D1% were significantly better with HT. SB sparing was significantly better for conventional IMRT at low doses (V10). Conclusions: Both HT and conventional IMRT provide optimal treatment of cervical cancer patients. The HT technique was significantly favored with regard to target conformity, homogeneity, and SB sparing. Randomized trials are needed to assess the oncological outcome, toxicity, and clinical relevance of these differences.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimal Normal Tissue Sparing in Craniospinal Axis Irradiation Using IMRT With Daily Intrafractionally Modulated Junction(s)

Purpose: To develop a treatment technique for craniospinal irradiation using intensity-modulated radiotherapy (IMRT) with improved dose homogeneity at the field junction(s), increased target volume conformity, and minimized dose to the organs at risk (OARs). Methods and Materials: Five patients with high-risk medulloblastoma underwent CT simulation in supine position. For each patient, an IMRT plan with daily intrafractionally modulated junction(s) was generated, as well as a treatment plan based on conventional three-dimensional planning (3DCRT). A dose of 39.6 Gy in 22 daily fractions of 1.8 Gy was prescribed. Dose-volume parameters for target volumes and OARs were compared for the two techniques. Results: The maximum dose with IMRT was <107% in all patients. V{sub <95} and V{sub >107} were <1 cm{sup 3} for IMRT compared with 3-9 cm{sup 3} for the craniospinal and 26-43 cm{sup 3} for the spinal-spinal junction with 3DCRT. These observations corresponded with a lower homogeneity index and a higher conformity index for the spinal planning target volume with IMRT. IMRT provided considerable sparing of acute and late reacting tissues. V{sub 75} for the esophagus, gastroesophageal junction, and intestine was 81%, 81%, and 22% with 3DCRT versus 5%, 0%, and 1% with IMRT, respectively. V{sub 75} for the heart and thyroid was 42% and 32% vs. 0% with IMRT. Conclusion: IMRT with daily intrafractionally modulated junction results in a superior target coverage and junction homogeneity compared with 3DCRT. A significant dose reduction can be obtained for acute as well as late-reacting tissues.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Field-in-Field Technique for Total Body Irradiation

Purpose: To evaluate the clinical use of a field-in-field (FIF) technique for total body irradiation (TBI) using a treatment-planning system (TPS) and to verify TPS results with in vivo dose measurements using metal-oxide-semiconductor field-effect transistor (MOSFET) detectors. Methods and Materials: Clinical and dosimetric data of 10 patients treated with TBI were assessed. Certain radiation parameters were measured using homogenous and regular phantoms at an extended distance of 380 cm, and the results were compared with data from a conventional standard distance of 100 cm. Additionally, dosimetric validation of TPS doses was performed with a Rando phantom using manual calculations. A three-dimensional computed tomography plan was generated involving 18-MV photon beams with a TPS for both open-field and FIF techniques. The midline doses were measured at the head, neck, lung, umbilicus, and pelvis for both open-field and FIF techniques. Results: All patients received planned TBI using the FIF technique with 18-MV photon energies and 2 Gy b.i.d. on 3 consecutive days. The difference in tissue maximum ratios between the extended and conventional distances was <2%. The mean deviation of manual calculations compared with TPS data was +1.6% (range, 0.1-2.4%). A homogenous dose distribution was obtained with 18-MV photon beams using the FIF technique. The mean lung dose for the FIF technique was 79.2% (9.2 Gy; range, 8.8-9.7 Gy) of the prescribed dose. The MOSFET readings and TPS doses in the body were similar (percentage difference range, -0.5% to 2.5%) and slightly higher in the shoulder and lung (percentage difference range, 4.0-5.5%). Conclusion: The FIF technique used for TBI provides homogenous dose distribution and is feasible, simple, and spares time compared with more-complex techniques. The TPS doses were similar to the midline doses obtained from MOSFET readings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Three-Isocenter Jagged-Junction IMRT Approach for Craniospinal Irradiation Without Beam Edge Matching for Field Junctions

Purpose: Traditionally craniospinal irradiation treats the central nervous system using two or three adjacent field sets. We propose a technique using a three-isocenter intensity-modulated radiotherapy (IMRT) plan (jagged-junction IMRT) which overcomes problems associated with field junctions and beam edge matching and improves planning and treatment setup efficiencies with homogenous target dose distribution. Methods and Materials: Treatments for 3 patients with a prescription of 36 Gy in 20 fractions were retrospectively planned with jagged-junction IMRT and compared to conventional treatment plans. Planning target volume (PTV) included the whole brain and spinal canal to the S3 vertebral level. The plan used three field sets, each with a unique isocenter. One field set with seven fields treated the cranium. Two field sets treated the spine, each set using three fields. Fields from adjacent sets were overlapped, and the optimization process smoothly integrated the dose inside the overlapped junction. Results: For jagged-junction IMRT plans vs. conventional technique, the average homogeneity index equaled 0.08 {+-} 0.01 vs. 0.12 {+-} 0.02, respectively, and conformity number equaled 0.79 {+-} 0.01 vs. 0.47 {+-} 0.12, respectively. The 95% isodose surface covered (99.5 {+-} 0.3)% of the PTV vs. (98.1 {+-} 2.0)%, respectively. Both jagged-junction IMRT plans and the conventional plans had good sparing of organs at risk. Conclusions: Jagged-junction IMRT planning provided good dose homogeneity and conformity to the target while maintaining a low dose to organs at risk. Results from jagged-junction IMRT plans were better than or equivalent to those from the conventional technique. Jagged-junction IMRT optimization smoothly distributed dose in the junction between field sets. Because there was no beam matching, this treatment technique is less likely to produce hot or cold spots at the junction, in contrast to conventional techniques. The planning process is also simplified as only one IMRT plan is required for the entire target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical Tomotherapy for Whole-Brain Irradiation With Integrated Boost to Multiple Brain Metastases: Evaluation of Dose Distribution Characteristics and Comparison With Alternative Techniques

Purpose: To quantitatively evaluate dose distribution characteristics achieved with helical tomotherapy (HT) for whole-brain irradiation (WBRT) with integrated boost (IB) to multiple brain metastases in comparison with alternative techniques. Methods and Materials: Dose distributions for 23 patients with 81 metastases treated with WBRT (30 Gy/10 fractions) and IB (50 Gy) were analyzed. The median number of metastases per patient (N{sub mets}) was 3 (range, 2-8). Mean values of the composite planning target volume of all metastases per patient (PTV{sub mets}) and of the individual metastasis planning target volume (PTV{sub ind} {sub met}) were 8.7 ± 8.9 cm{sup 3} (range, 1.3-35.5 cm{sup 3}) and 2.5 ± 4.5 cm{sup 3} (range, 0.19-24.7 cm{sup 3}), respectively. Dose distributions in PTV{sub mets} and PTV{sub ind} {sub met} were evaluated with respect to dose conformity (conformation number [CN], RTOG conformity index [PITV]), target coverage (TC), and homogeneity (homogeneity index [HI], ratio of maximum dose to prescription dose [MDPD]). The dependence of dose conformity on target size and N{sub mets} was investigated. The dose distribution characteristics were benchmarked against alternative irradiation techniques identified in a systematic literature review. Results: Mean ± standard deviation of dose distribution characteristics derived for PTV{sub mets} amounted to CN = 0.790 ± 0.101, PITV = 1.161 ± 0.154, TC = 0.95 ± 0.01, HI = 0.142 ± 0.022, and MDPD = 1.147 ± 0.029, respectively, demonstrating high dose conformity with acceptable homogeneity. Corresponding numbers for PTV{sub ind} {sub met} were CN = 0.708 ± 0.128, PITV = 1.174 ± 0.237, TC = 0.90 ± 0.10, HI = 0.140 ± 0.027, and MDPD = 1.129 ± 0.030, respectively. The target size had a statistically significant influence on dose conformity to PTV{sub mets} (CN = 0.737 for PTV{sub mets} ≤4.32 cm{sup 3} vs CN = 0.848 for PTV{sub mets} >4.32 cm{sup 3}, P=.006), in contrast to N{sub mets}. The achieved dose conformity to PTV{sub mets}, assessed by both CN and PITV, was in all investigated volume strata well within the best quartile of the values reported for alternative irradiation techniques. Conclusions: HT is a well-suited technique to deliver WBRT with IB to multiple brain metastases, yielding high-quality dose distributions. A multi-institutional prospective randomized phase 2 clinical trial to exploit efficacy and safety of the treatment concept is currently under way.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Supine Craniospinal Irradiation Using a Proton Pencil Beam Scanning Technique Without Match Line Changes for Field Junctions

Purpose: To propose and validate a craniospinal irradiation approach using a proton pencil beam scanning technique that overcomes the complexity of the planning associated with feathering match lines. Methods and Materials: Ten craniospinal irradiation patients had treatment planned with gradient dose optimization using the proton pencil beam scanning technique. The robustness of the plans was evaluated by shifting the isocenter of each treatment field by ±3 mm in the longitudinal direction and was compared with the original nonshifted plan with metrics of conformity number, homogeneity index, and maximal cord doses. An anthropomorphic phantom study using film measurements was carried out on a plan with 5-cm junction length. To mimic setup errors in the phantom study, fields were recalculated with isocenter shifts of 1, 3, 5, and 10 mm longitudinally, and compared with the original plans and measurements. Results: Uniform dose coverage to the entire target volumes was achieved using the gradient optimization approach with averaged junction lengths of 6.7 ± 0.5 cm. The average conformity number and homogeneity index equaled 0.78 ± 0.03 and 1.09 ± 0.01, respectively. Setup errors of 3 mm per field (6 mm in worst-case scenario) caused on average 4.6% lower conformity number 2.5% higher homogeneity index and maximal cord dose of 4216.1 ± 98.2 cGy. When the junction length was 5 cm or longer, setup errors of 6 mm resulted in up to 12% dosimetric deviation. Consistent results were reached between film measurements and planned dose profiles in the junction area. Conclusions: Longitudinal setup errors directly reduce the dosimetric accuracy of the proton craniospinal irradiation treatment with matched proton pencil beam scanning fields. The reported technique creates a slow dose gradient in the junction area, which makes the treatment more robust to longitudinal setup errors compared to conventional feathering methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploratory Study of 4D versus 3D Robust Optimization in Intensity Modulated Proton Therapy for Lung Cancer

Purpose: The purpose of this study was to compare the impact of uncertainties and interplay on 3-dimensional (3D) and 4D robustly optimized intensity modulated proton therapy (IMPT) plans for lung cancer in an exploratory methodology study. Methods and Materials: IMPT plans were created for 11 nonrandomly selected non-small cell lung cancer (NSCLC) cases: 3D robustly optimized plans on average CTs with internal gross tumor volume density overridden to irradiate internal target volume, and 4D robustly optimized plans on 4D computed tomography (CT) to irradiate clinical target volume (CTV). Regular fractionation (66 Gy [relative biological effectiveness; RBE] in 33 fractions) was considered. In 4D optimization, the CTV of individual phases received nonuniform doses to achieve a uniform cumulative dose. The root-mean-square dose-volume histograms (RVH) measured the sensitivity of the dose to uncertainties, and the areas under the RVH curve (AUCs) were used to evaluate plan robustness. Dose evaluation software modeled time-dependent spot delivery to incorporate interplay effect with randomized starting phases of each field per fraction. Dose-volume histogram (DVH) indices comparing CTV coverage, homogeneity, and normal tissue sparing were evaluated using Wilcoxon signed rank test. Results: 4D robust optimization plans led to smaller AUC for CTV (14.26 vs 18.61, respectively; P=.001), better CTV coverage (Gy [RBE]) (D{sub 95%} CTV: 60.6 vs 55.2, respectively; P=.001), and better CTV homogeneity (D{sub 5%}-D{sub 95%} CTV: 10.3 vs 17.7, resspectively; P=.002) in the face of uncertainties. With interplay effect considered, 4D robust optimization produced plans with better target coverage (D{sub 95%} CTV: 64.5 vs 63.8, respectively; P=.0068), comparable target homogeneity, and comparable normal tissue protection. The benefits from 4D robust optimization were most obvious for the 2 typical stage III lung cancer patients. Conclusions: Our exploratory methodology study showed that, compared to 3D robust optimization, 4D robust optimization produced significantly more robust and interplay-effect-resistant plans for targets with comparable dose distributions for normal tissues. A further study with a larger and more realistic patient population is warranted to generalize the conclusions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deformation mechanisms in amorphous Ni–Mo–P films coated on CoCrFeNi high-entropy alloys

The Ni–Mo–P amorphous films were successfully deposited on the CoCrFeNi high-entropy alloys by electroless plating. This work will focus on reviewing and discussing the ambient-temperature mechanical properties, plastic deformation, and cracking mode of the coating-substrate system. The yielding strength (σ y ) and ultimate tensile strength (UTS) of the specimen plating for 1 h were 260 and 760 MPa, respectively, with 44.4% (σ y ) and 14.2% (UTS) improvement contrast to the uncoated HEAs (σ y and UTS are 180 MPa and 560 MPa, respectively). It is attributed to the back stress and repulsive image stress to suppress the nucleation and mobility of dislocations. Due to the substrate confinement, the deformation model was gradually changed from cracking (with homogeneous flow) to shear banding (with homogeneous flow). Eventually, fully-homogeneous flows occur with reducing the film thickness, and the deformation mechanism map is developed to expound the transition of the deformation mode. The brittle fracture with a high velocity originating from amorphous films leads to cleavage cracking on the surface of the HEA substrate. The thicker film has higher crack velocity and causes deeper cracks penetration into the substrate, reducing the substrate ductility.

36 MATERIALS SCIENCE↗

Tailoring Silica-alumina Supported Pt-Pd As Poison Tolerant Catalyst For Aromatics Hydrogenation

The tailoring of the physicochemical and catalytic properties of mono- and bimetallic Pt-Pd catalysts supported on amorphous silica-alumina is studied. Electron energy loss spectroscopy and extended X-ray absorption fine structure analyses indicated that bimetallic Pt-Pd and relatively large monometallic Pd particles were formed, whereas the X-ray absorption near edge structure provided direct evidence for the electronic deficiency of the Pt atoms. The heterogeneous distribution of metal particles was also shown by high resolution transmission electron microscopy. The average structure of the bimetallic particles (Pt-rich core and Pd-rich shell) and the presence of Pd particles led to surface Pd enrichment, which was independently shown by IR spectra of adsorbed CO. The specific metal distribution, average size, and surface composition of the Pt-Pd particles depend to a large extent on the metal precursors. In the presence of NH3 ligands, Pt-Pd particles with a fairly homogeneous bulk and surface metal distribution were formed. Also high Lewis acid site concentration of the carrier leads to more homogeneous bimetallic particles. All catalysts were active for the hydrogenation of tetralin in the absence and presence of quinoline and dibenzothiophene (DBT). Monometallic Pt catalysts had the highest hydrogenation activity in poison-free and quinoline-containing feed. When DBT was present, bimetallic Pt-Pd catalysts with the most homogenous metal distribution showed the highest activity. The higher resistance of bimetallic catalysts towards sulfur poisoning compared to their monometallic Pt counterparts results from the weakened metal-sulfur bond on the electron deficient Pt atoms. Thus, increasing the fraction of electron deficient Pt on the surface of the bimetallic particles increases the efficiency of the catalyst in the presence of sulfur.

Environmental Molecular Sciences Laboratory↗

Topological origin of phase separation in hydrated gels

Depending on their composition, hydrated gels can be homogeneous or phase-separated, which, in turn, affects their dynamical and mechanical properties. However, the nature of the structural features, if any, that govern the propensity for a given gel to phase-separate remains largely unknown. Here, we argue that the propensity for hydrated gels to phase-separate is topological in nature. We employ reactive molecular dynamics simulations to model the early-age precipitation of calcium–alumino–silicate–hydrate (Csingle bondAsingle bondSsingle bondH) gels with varying compositions, i.e., (CaO) 1.7 (Al 2 O 3 ) x (SiO 2 ) 1 – x (H 2 O) 3.7 + x . By adopting topological constraint theory, we investigate the structural origin of phase separation in hydrated gels. We report the existence of a homogeneous-to-phase-separated transition, wherein Si-rich (x ≤ 0.10) Csingle bondAsingle bondSsingle bondH gels are homogeneous, whereas Al-rich (x > 0.10) Csingle bondAsingle bondSsingle bondH gels tend to phase-separate. Furthermore, we demonstrate that this transition is correlated to a topological flexible-to-rigid transition within the atomic network. Finally, we reveal that the propensity for topologically-overconstrained gels to phase-separate arises from the existence of some internal stress within their atomic network, which acts as an energy penalty that drives phase separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimal lattice-structured materials

This paper describes a method for optimizing the mesostructure of lattice-structured materials. These materials are periodic arrays of slender members resembling efficient, lightweight macroscale structures like bridges and frame buildings. Current additive manufacturing technologies can assemble lattice structures with length scales ranging from nanometers to millimeters. Previous work demonstrates that lattice materials have excellent stiffness- and strength-to-weight scaling, outperforming natural materials. However, there are currently no methods for producing optimal mesostructures that consider the full space of possible 3D lattice topologies. The inverse homogenization approach for optimizing the periodic structure of lattice materials requires a parameterized, homogenized material model describing the response of an arbitrary structure. This work develops such a model, starting with a method for describing the long-wavelength, macroscale deformation of an arbitrary lattice. The work combines the homogenized model with a parameterized description of the total design space to generate a parameterized model. Finally, the work describes an optimization method capable of producing optimal mesostructures. Several examples demonstrate the optimization method. One of these examples produces an elastically isotropic, maximally stiff structure, here called the isotruss, that arguably outperforms the anisotropic octet truss topology.

36 MATERIALS SCIENCE↗

Ion irradiation induced nucleation and growth of nanoparticles in amorphous silicon carbide at elevated temperatures

Ion irradiation induced crystallization in as-deposited amorphous SiC films is investigated using grazing-angle incidence x-ray diffraction (GIXRD), transmission electron microscopy (TEM) and Raman spectroscopy. Irradiation with 5 MeV Xe to fluence of 115 Xe/nm2 at 700 K results in a homogenous distribution of 3C-SiC grains with an average crystallite size of ~5.7 nm over the entire film thickness (~1 µm). The nucleation and growth processes exhibit a weak dependence on dose in displacements per atom (dpa) in the dose range from 6 to 20 dpa. A transformation of homonuclear C-C bonds from sp3 to sp2 hybridization is observed in the irradiated films, which may be partly responsible for the observed grain size saturation. The results from this study may have a significant impact on synthesis of nanograins in amorphous SiC and other similar materials with effective control of grain size and density by ion irradiation.

phase transformation, SiC, ion irradiation↗

Resilience of uranium mononitride/zirconium carbide composites and uranium-zirconium carbonitride in hot hydrogen for nuclear thermal propulsion

Nuclear thermal rockets require fuels capable of withstanding flowing hydrogen propellant up to 3200 K. Presently, there has not been a fuel type that reliably operates at these conditions. A promising candidate anticipated to endure this demanding environment is a ceramic-ceramic composite comprising of uranium mononitride and zirconium carbide. Further, this investigation assesses the behavior and resilience of variations of this composite and its resultant homogenized form (uranium-zirconium carbonitride) under two hot hydrogen conditions (2273 K and 3000 K). The findings revealed that composites that homogenize into UZrCN exhibit superior structural integrity in hydrogen compared to heterogeneous counterparts. Consequently, this study underscores the potential of homogenized uranium-zirconium carbonitride for enhanced performance in nuclear thermal propulsion applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enhanced mechanical strength and electrochemical performance of core–shell structured high–nickel cathode material

Improving capacity retention during cycling and the thermal–abuse tolerance of layered high–nickel cathode material, LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811), is a significant challenge. In this work, a series of core–shell structured cathode materials with the overall composition of LiNi 0.8 Mn 0.1 Co 0.1 O 2 was prepared via a coprecipitation method in which the nickel–rich composition (LiNi 0.9 Mn 0.05 Co 0.05 O 2 ) is the core and the manganese–rich composition (LiNi 0.33 Mn 0.33 Co 0.33 O 2 ) is the shell. In terms of achieving a higher nickel content (more than 80%) of heterogeneous material, this core–shell structured material is a more practical approach because it has a larger nickel–rich core region and a thicker manganese–rich shell than the full–concentration gradient material, not to mention being more feasible for continuous mass production. Analysis of mechanical strength through nanoindentation shows that the core–shell structured NMC811 has higher stiffness and compressive stress–strain than the commercial homogeneous NMC811 and retains the mechanical strength and the binding force strong enough to prevent crack formation even after 200 cycles. The prepared core–shell structure NMC811 exhibits a greatly improved capacity retention of 76.6% compared to the commercial homogeneous NMC811 with a capacity retention of 39.6% after 200 cycles. This material also exhibits significantly improved thermal stability over the commercial homogeneous NMC811.

25 ENERGY STORAGE↗

Size-dependent fluorescence of bioaerosols: Mathematical model using fluorescing and absorbing molecules in bacteria

This paper uses a mathematical model of fluorescent biological particles composed of bacteria and/or proteins (mostly as in Hill et al., 2013 [23]) to investigate the size-dependence of the total fluorescence emitted in all directions. The model applies to particles which have negligible reabsorption of fluorescence within the particle. The specific particles modeled here are composed of ovalbumin and of a generic Bacillus. The particles need not be spherical, and in some cases need not be homogeneous. However, the results calculated in this paper are for spherical homogeneous particles. Light absorbing and fluorescing molecules included in the model are amino acids, nucleic acids, and several coenzymes. Here the excitation wavelength is 266 nm. The emission range, 300 to 370 nm, encompasses the fluorescence of tryptophan. The fluorescence cross section (C F ) is calculated and compared with one set of published measured values. We investigate power law (Ad y ) approximations to C F , where d is diameter, and A and y are parameters adjusted to fit the data, and examine how y varies with d and composition, including the fraction as water. The particle's fluorescence efficiency (Q F =C F /geometric-cross-section) can be written for homogeneous particles as Q abs R F , where Q abs is the absorption efficiency, and R F , the fraction of the absorbed light emitted as fluorescence, is independent of size and shape. When Q F is plotted vs. m i d or mi(m r -1)d, where m=m r +im i is the complex refractive index, the plots for different fractions of water in the particle tend to overlap.

54 ENVIRONMENTAL SCIENCES↗

New real ternary and pseudoternary phases in the Li-Au-In system

Two real ternary lithium gold indides LiAu{sub 2}In and Li{sub 280}Au{sub 22}In{sub 130} (Li{sub 0.65}Au{sub 0.05}In{sub 0.30}) were found in the Li-Au-In system. They are isostructural to the respective Ag-alloys. LiAu{sub 2}In crystallizes in the MnCu{sub 2}Al-type structure (Fm-3m, Heusler phase, a=6.4982(8) A, based on single crystal XRD-data) and Li{sub 280}Au{sub 22}In{sub 130} in the Li{sub 278}Ag{sub 40}In{sub 114}-type structure (F-43m, a=19.9970(2) A, based on powder XRD-data). The analogy of the two ternary systems Li-Au-In and Li-Ag-In is additionally reaffirmed by the wide homogeneity range of the pseudoternary solid solution with NaTl-type structure (Zintl phase),which expands not only in the direction of the quasibinary cut Li(Au{sub x}In{sub 1-x}) with 0{<=}x{<=}0.5, but also into the directions of both higher and lower Li-concentrations. -- Graphical abstract: Two real ternary compounds (1: Heusler phase, 2: n=6 variant of a cubic nxnxn W-type superstructure) together with one pseudoternary compound (3: Zintl phase with its broad homogeneity range). Display Omitted Highlights: {yields} 'Real' ternary phases were found in the Li-Au-In systems: LiAu{sub 2}In and Li{sub 280}Au{sub 22}In{sub 130}. {yields} The homogeneity range of 'pseudoternary' Li(Au{sub x}In{sub 1-x}) extends to the binary phase x=0. {yields} The three-element sets, both Li, Au, In and Li, Ag, In, are compound formers*. (*in the definition of Villars et al., J. Alloys Compd. 317-318, 2001, 26).

36 MATERIALS SCIENCE↗