Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “H- source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

HIGH RESOLUTION H{alpha} IMAGES OF THE BINARY LOW-MASS PROPLYD LV 1 WITH THE MAGELLAN AO SYSTEM

We utilize the new Magellan adaptive optics system (MagAO) to image the binary proplyd LV 1 in the Orion Trapezium at H{alpha}. This is among the first AO results in visible wavelengths. The H{alpha} image clearly shows the ionization fronts, the interproplyd shell, and the cometary tails. Our astrometric measurements find no significant relative motion between components over {approx}18 yr, implying that LV 1 is a low-mass system. We also analyze Large Binocular Telescope AO observations, and find a point source which may be the embedded protostar's photosphere in the continuum. Converting the H magnitudes to mass, we show that the LV 1 binary may consist of one very-low-mass star with a likely brown dwarf secondary, or even plausibly a double brown dwarf. Finally, the magnetopause of the minor proplyd is estimated to have a radius of 110 AU, consistent with the location of the bow shock seen in H{alpha}.

79 ASTRONOMY AND ASTROPHYSICS↗

Photon energy spectrum emitted by a novel polymer-encapsulated {sup 103}Pd source and its effect on the dose rate constant

Two independent groups have published intrinsic dosimetry parameters for the recently introduced OptiSeed{sup 103} interstitial brachytherapy source which contains {sup 103}Pd encapsulated by a novel polymer shell. The dose rate constant ({lambda}) reported by the two groups, however, differed by more than 6% and there is currently no AAPM recommended consensus value for this source in clinical dosimetry. The aim of this work was to perform an independent determination of {lambda} for the OptiSeed{sup 103} source using a recently developed photon spectrometry technique. Three OptiSeed{sup 103} sources (model 1032P) with known air-kerma strength were used in this study. The photon energy spectrum emitted along the radial direction on the source's bisector was measured in air using a high-resolution intrinsic germanium spectrometer designed and established for low-energy brachytherapy source spectrometry. The dose rate constant of each source was determined from its emitted energy spectrum and the spatial distribution of radioactivity in the source. Unlike other sources made with traditional titanium encapsulation, the photons emitted by the OptiSeed{sup 103} sources exhibited only slight spectral hardening, yielding a relative energy spectrum closer to that emitted by bare {sup 103}Pd. The dose rate constant determined by the photon spectrometry technique for water was 0.664{+-}0.025 cGy h{sup -1} U{sup -1}. This value agreed, within experimental uncertainties, with the Monte Carlo-calculated value ({sub MC}{lambda}) of 0.665{+-}0.014 cGy h{sup -1} U{sup -1} and the TLD-measured value (with a Monte Carlo-calculated solid-phantom-to-water conversion factor) of 0.675{+-}0.051 cGy h{sup -1} U{sup -1} reported by Wang and Hertel [Appl. Radiat. Isot. 63, 311-321 (2005)]. However, it differed by -6.7% from the {sub MC}{lambda} of 0.712{+-}0.043 cGy h{sup -1} U{sup -1} reported by Bernard and Vynckier [Phys. Med. Biol. 50, 1493-1504 (2005)]. The results obtained in this work provide additional information needed for establishing a consensus value for the dose rate constant for the OptiSeed{sup 103} source. It suggests that an eventual consensus value of {lambda} for the OptiSeed{sup 103} source is likely to be closer to a value of 0.668 cGy h{sup -1} U{sup -1} rather than 0.693 cGy h{sup -1}U{sup -1} as initially recommended by the source manufacturer based on the two previously published results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A HOT MOLECULAR CIRCUMSTELLAR DISK AROUND THE MASSIVE PROTOSTAR ORION SOURCE I

We report new Atacama Large Millimeter/Submillimeter Array (ALMA) observations of a circumstellar disk around Source I in Orion KL, an archetype of massive protostar candidates. We detected two ortho-H{sub 2}O lines at 321 GHz (10{sub 2,} {sub 9}-9{sub 3,} {sub 6}) and 336 GHz (ν{sub 2} = 1, 5{sub 2,} {sub 3}-6{sub 1,} {sub 6}) for the first time in Source I. The latter one is in a vibrationally excited state at the lower state energy of 2939 K, suggesting evidence of hot molecular gas close to Source I. The integrated intensity map of the 321 GHz line is elongated along the bipolar outflow while the 336 GHz line map is unresolved with a beam size of 0.''4. Both of these maps show velocity gradients perpendicular to the bipolar outflow. The velocity centroid map of the 321 GHz line implies a spatial and velocity structure similar to that of vibrationally excited SiO masers tracing the root of the outflow emanating from the disk surface. In contrast, the 336 GHz line is most likely emitting from the disk midplane with a diameter of 0.''2 (84 AU) as traced by radio continuum emission and a dark lane devoid of the vibrationally excited SiO maser emission. The observed velocity gradient and the spectral profile of the 336 GHz H{sub 2}O line can be reconciled with a model of an edge-on ring-like structure with an enclosed mass of >7 M{sub ☉} and an excitation temperature of >3000 K. The present results provide further evidence of a hot and neutral circumstellar disk rotating around Source I with a diameter of ∼100 AU scale.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of 3-panel and 4-panel microscale ionization sources

Two designs of a microscale electron ionization (EI) source are analyzed herein: a 3-panel design and a 4-panel design. Devices were fabricated using microelectromechanical systems technology. Field emission from carbon nanotube provided the electrons for the EI source. Ion currents were measured for helium, nitrogen, and xenon at pressures ranging from 10{sup -4} to 0.1 Torr. A comparison of the performance of both designs is presented. The 4-panel microion source showed a 10x improvement in performance compared to the 3-panel device. An analysis of the various factors affecting the performance of the microion sources is also presented. SIMION, an electron and ion optics software, was coupled with experimental measurements to analyze the ion current results. The electron current contributing to ionization and the ion collection efficiency are believed to be the primary factors responsible for the higher efficiency of the 4-panel microion source. Other improvements in device design that could lead to higher ion source efficiency in the future are also discussed. These microscale ion sources are expected to find application as stand alone ion sources as well as in miniature mass spectrometers.

07 ISOTOPE AND RADIATION SOURCES↗

Recent developments of ion sources for life-science studies at the Heavy Ion Medical Accelerator in Chiba (invited)

With about 1000-h of relativistic high-energy ion beams provided by Heavy Ion Medical Accelerator in Chiba, about 70 users are performing various biology experiments every year. A rich variety of ion species from hydrogen to xenon ions with a dose rate of several Gy/min is available. Carbon, iron, silicon, helium, neon, argon, hydrogen, and oxygen ions were utilized between 2012 and 2014. Presently, three electron cyclotron resonance ion sources (ECRISs) and one Penning ion source are available. Especially, the two frequency heating techniques have improved the performance of an 18 GHz ECRIS. The results have satisfied most requirements for life-science studies. In addition, this improved performance has realized a feasible solution for similar biology experiments with a hospital-specified accelerator complex.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

XMM-NEWTON OBSERVATIONS OF LUMINOUS SOURCES IN NEARBY GALAXIES NGC 4395, NGC 4736, AND NGC 4258

We present the results of a study of non-nuclear discrete sources in a sample of three nearby spiral galaxies (NGC 4395, NGC 4736, and NGC 4258) based on XMM-Newton archival data supplemented with Chandra data for spectral and timing analyses. A total of 75 X-ray sources have been detected within the D{sub 25} regions of the target galaxies. The large collecting area of XMM-Newton makes the statistics sufficient to obtain spectral fitting for 16 (about 20%) of these sources. Compiling the extensive archival exposures available, we were able to obtain the detailed spectral shapes of diverse classes of point sources. We have also studied temporal properties of these luminous sources. Eleven of them are found to show short-term (less than 80 ks) variation while eight of them show long-term variation within factors of {approx}2-5 during a time interval of {approx}2-12 years. Timing analysis provides strong evidence that most of these sources are accreting X-ray binary systems. One source that has properties different from others was suspected to be a supernova remnant, and our follow-up optical observation confirmed this. Our results indicate that sources within the three nearby galaxies are showing a variety of source populations, including several ultraluminous X-ray sources, X-ray binaries, transients together with a super soft source, and a background active galactic nucleus candidate.

79 ASTRONOMY AND ASTROPHYSICS↗

Speciated measurements of semivolatile and intermediate volatility organic compounds (S/IVOCs) in a pine forest during BEACHON-RoMBAS 2011

Understanding organic composition of gases and particles is essential to identifying sources and atmospheric processing leading to organic aerosols (OA), but atmospheric chemical complexity and the analytical techniques available often limit such analysis. Here we present speciated measurements of semivolatile and intermediate volatility organic compounds (S/IVOCs) using a novel dual-use instrument (SV-TAG-AMS) deployed at Manitou Forest, CO, during the Bio-hydro-atmosphere interactions of Energy, Aerosols, Carbon, H 2 O, Organics & Nitrogen – Rocky Mountain Biogenic Aerosol Study (BEACHON-RoMBAS) 2011 campaign. This instrument provides on-line speciation of ambient organic compounds with 2 h time resolution. The species in this volatility range are complex in composition, but their chemical identities reveal potential sources. Observed compounds of biogenic origin include sesquiterpenes with molecular formula C 15 H 24 (e.g., β -caryophyllene and longifolene), which were most abundant at night. A variety of other biogenic compounds were observed, including sesquiterpenoids with molecular formula C 15 H 22 , abietatriene and other terpenoid compounds. Many of these compounds have been identified in essential oils and branch enclosure studies but were observed in ambient air for the first time in our study. Semivolatile polycyclic aromatic hydrocarbons (PAHs) and alkanes were observed with highest concentrations during the day and the dependence on temperature suggests the role of an evaporative source. Using statistical analysis by positive matrix factorization (PMF), we classify observed S/IVOCs by their likely sources and processes, and characterize them based on chemical composition. The total mass concentration of elutable S/IVOCs was estimated to be on the order of 0.7 µg m –3 and their volatility distributions are estimated for modeling aerosol formation chemistry.

54 ENVIRONMENTAL SCIENCES↗

The local value of H{sub 0} in an inhomogeneous universe

The effects of local inhomogeneities on low redshift H{sub 0} determinations are studied by estimating the redshift-distance relation of mock sources in N-body simulations. The results are compared to those obtained using the standard approach based on Hubble's law. The comparison shows a clear tendency for the standard approach to yield lower values of H{sub 0} than the approach based on the scheme using light rays. The difference is, however, small. More precisely, it is found that the overall effect of inhomogeneities on the determination of H{sub 0} is a small increase in the local estimates of about 0.3% compared to the results obtained with Hubble's law, when based on a typical distribution of supernovae in the redshift range 0.01 < z < 0.1. The overall conclusion of the study is a verification of the results that have earlier been obtained by using Hubble's law: the effects of inhomogeneities on local H{sub 0} estimates are not significant enough to make it plausible that differences in high- and low-redshift estimates of H{sub 0} are due to small inhomogeneities within the setting of standard cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

An (e, 2e + ion) study of low-energy electron-impact ionization and fragmentation of tetrahydrofuran with high mass and energy resolutions

We study the low-energy (E{sub 0} = 26 eV) electron-impact induced ionization and fragmentation of tetrahydrofuran using a reaction microscope. All three final-state charged particles, i.e., two outgoing electrons and one fragment ion, are detected in triple coincidence such that the momentum vectors and, consequently, the kinetic energies for charged reaction products are determined. The ionic fragments are clearly identified in the experiment with a mass resolution of 1 amu. The fragmentation pathways of tetrahydrofuran are investigated by measuring the ion kinetic energy spectra and the binding energy spectra where an energy resolution of 1.5 eV has been achieved using the recently developed photoemission electron source. Here, we will discuss the fragmentation reactions for the cations C{sub 4}H{sub 8}O{sup +}, C{sub 4}H{sub 7}O{sup +}, C{sub 2}H{sub 3}O{sup +}, C{sub 3}H{sub 6}{sup +}, C{sub 3}H{sub 5}{sup +}, C{sub 3}H{sub 3}{sup +}, CH{sub 3}O{sup +}, CHO{sup +}, and C{sub 2}H{sub 3}{sup +}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reaction of Hydrazine with Solution- and Vacuum-Prepared Selectively Terminated Si(100) Surfaces: Pathways to the Formation of Direct Si–N Bonds

Here, the reactivity of liquid hydrazine (N 2 H 4 ) with respect to H-, Cl-, and Br-terminated Si(100) surfaces was investigated to uncover the principles of nitrogen incorporation into the interface. This process has important implications in a wide variety of applications, including semiconductor surface passivation and functionalization, nitride growth, and many others. The use of hydrazine as a precursor allows for reactions that exclude carbon and oxygen, the primary sources of contamination in processing. In this work, the reactivity of N 2 H 4 with H- and Cl-terminated surfaces prepared by traditional solvent-based methods and with a Br-terminated Si(100) prepared in ultrahigh vacuum was compared. The reactions were studied with X-ray photoelectron spectroscopy, atomic force microscopy, and scanning tunneling microscopy, and the observations were supported by computational investigations. The H-terminated surface led to the highest level of nitrogen incorporation; however, the process proceeds with increasing surface roughness, suggesting possible etching or replacement reactions. In the case of Cl-terminated (predominantly dichloride) and Br-terminated (monobromide) surfaces, the amount of nitrogen incorporation on both surfaces after the reaction with hydrazine was very similar despite the differences in preparation, initial structure, and chemical composition. Density functional theory was used to propose the possible surface structures and to analyze surface reactivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Negative ion production in cesium seeded high electron temperature plasmas

In experiments on uniformity improvement in a large negative ion source, steep gradients have been observed in the profiles of electron temperature and H{sup -} ion beam intensity. It has been observed that the gradient in the H{sup -} ion beam intensity is altered by seeding cesium, though the electron temperature distribution is not affected by Cs. Thus in the Cs seeded condition, the H{sup -} ion beam intensity is enhanced in local area illuminated by high electron temperature plasmas. A brief analysis suggests possible advantages of high electron temperature plasmas for the negative ion surface production, by enhancement of dissociation to yield proton or atoms as parent particles of the negative ions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bright, Coherent, Ultrafast Soft X-Ray Harmonics Spanning the Water Window from a Tabletop Light Source

We demonstrate fully phase-matched high harmonic emission spanning the water window spectral region important for nano- and bioimaging and a breadth of materials and molecular dynamics studies. We also generate the broadest bright coherent bandwidth ({approx_equal}300 eV) to date from any light source, small or large, that is consistent with a single subfemtosecond burst. The harmonic photon flux at 0.5 keV is 10{sup 3} higher than demonstrated previously. This work extends bright, spatially coherent, attosecond pulses into the soft x-ray region for the first time.

07 ISOTOPE AND RADIATION SOURCES↗

H{sub 2}—AgCl: A spectroscopic study of a dihydrogen complex

H{sub 2}—AgCl has been observed on a Fourier transform microwave spectrometer equipped with laser ablation source and determined to be a dihydrogen complex. Transitions up to J = 3–2 have been measured and analyzed for four isotopologues of the complex containing ortho and para H{sub 2}. The ortho and para spin states have been included in one fit, a deviation from the typical H{sub 2} complex. Rotational constants B and C, centrifugal distortion constants Δ{sub J} and Δ{sub JK}, nuclear electric quadrupole coupling constants χ{sub aa}, χ{sub bb}, and χ{sub cc} for {sup 35}Cl and {sup 37}Cl have been fit for both spin states while nuclear spin-nuclear spin constants D{sub aa}, D{sub bb}, and D{sub cc}, and nuclear spin-rotation constant C{sub aa} have been reported for the ortho spin state. Quantum chemical calculations predict a strong bonding interaction and the strength of the complex has been related to reported χ{sub aa} and Δ{sub J} values amongst a host of comparable species, including the AgCl monomer itself. Bond lengths have been determined for Ag—Cl, Ag—H{sub 2} center-of-mass, and H—H and are reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation of SOLPS-ITER and EDGE2D-EIRENE simulations for H, D, and T JET ITER-like wall low-confinement mode plasmas

Both experiments and simulations with SOLPS-ITER and EDGE2D-EIRENE show that the onset of detachment for the low-field side (LFS) divertor – defined here as the line-averaged upstream density (〈n e 〉 edge ) at which the plasma flux to the LFS target (I LFS-plate ) starts to decrease with increasing 〈n e 〉 edge – is independent of the isotope mass. However, there are three major simulation-experiment discrepancies: (i) the absolute values of I LFS-plate and the electron density (n e ) in the LFS divertor at the onset of detachment are significantly lower in simulations, i.e., approximately a factor of 2 for I LFS-plate and a factor of 3-4 for n e ; (ii) the degree of detachment – defined here as the difference between I LFS-plate at the onset of detachment and at an 〈n e 〉 edge value close to the density limit – is smaller in simulations compared to experiments; and (iii) the experimentally observed larger degree of detachment for D and T plasmas compared to H plasmas cannot be clearly distinguished from the simulation results. There are strong indications that discrepancy (i) is to a large extent caused by neglecting Lyman-opacity effects in our simulations. The simulations predict a similar net volumetric recombination source for all isotopes due to the fact that molecule-activated recombination (MAR) compensates for the reduced electron–ion recombination (EIR) for H, whereas MAR is negligible for D and T. This similar net volumetric recombination source for all isotopes leads to an isotope-independent degree of detachment in simulations. An analysis of the Balmer-α and Balmer-$γ$ emission confirms the underestimate of MAR in simulations (especially for D and T) for the JET metallic wall, which was previously observed for devices with a carbon wall. The underestimate of MAR is an important cause for discrepancy (ii) and the fact that there is a stronger underestimate of MAR for D and T than for H explains discrepancy (iii). Extending the plasma grid to the vessel wall increases I LFS-plate and n e at the onset of detachment by 25%, and the EIR source increases by 80% in detached conditions. Hence, while the extended grid results are closer to the experimental observations, the previously described qualitative discrepancies still persist.

Balmer emission↗

SiO{sub 2} nanospheres with tailorable interiors by directly controlling Zn{sup 2+} and NH{sub 3}.H{sub 2}O species in an emulsion process

SiO{sub 2} nanospheres with tailorable interiors were synthesized by a facile one-spot microemulsion process using TEOS as silica source, wherein cyclohexane including triton X-100 and n-octanol as oil phase and Zn{sup 2+} or NH{sub 3}.H{sub 2}O aqueous solution as dispersive phase, respectively. The products were characterized by Scanning Electron Microscopy, Transmission Electron Microscopy and X-ray Powder Diffraction. It was suggested that the as-synthesized silica nanospheres possessed grape-stone-like porous or single hollow interior, and also found that the ammonia dosage and aging time played key roles in controlling the size and structure of silica nanospheres. Furthermore, the comparative results confirmed that in-situ zinc species [ZnO/Zn(OH){sub 2}] acted as the temporary templates to construct grape-stone-like interior, and a simultaneously competing etching process occurred owing to the soluble Zn(NH{sub 3}){sub 4}{sup 2+} complex formation while the additional excessive ammonia was introduced. With the aging time being extended, the in-situ nanocrystals tended to grow into bigger ones by Ostwald Ripening, producing single hollow interior. - Graphical Abstract: Formation process of SiO{sub 2} nanospheres with porous and single hollow interior. Highlights: > ZnO/Zn(OH){sub 2} nanocrystals as the temporary templates shape the interior structures of SiO{sub 2} nanospheres. > Fabrication of porous and single hollow interiors needs no additional processes such as roasting or dissolving. > Tailorable interiors can be easily obtained through adjusting the aging time of temporary templates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NEAR-INFRARED GALAXY COUNTS AND EVOLUTION FROM THE WIDE-FIELD ALHAMBRA SURVEY

The ALHAMBRA survey aims to cover 4 deg{sup 2} using a system of 20 contiguous, equal width, medium-band filters spanning the range 3500 A-9700 A plus the standard JHKs filters. Here we analyze deep near-IR number counts of one of our fields (ALH08) for which we have a relatively large area (0.5 deg{sup 2}) and faint photometry (J = 22.4, H = 21.3, and K = 20.0 at the 50% of recovery efficiency for point-like sources). We find that the logarithmic gradient of the galaxy counts undergoes a distinct change to a flatter slope in each band: from 0.44 at [17.0, 18.5] to 0.34 at [19.5, 22.0] for the J band; for the H band 0.46 at [15.5, 18.0] to 0.36 at [19.0, 21.0], and in Ks the change is from 0.53 in the range [15.0, 17.0] to 0.33 in the interval [18.0, 20.0]. These observations together with faint optical counts are used to constrain models that include density and luminosity evolution of the local type-dependent luminosity functions. Our models imply a decline in the space density of evolved early-type galaxies with increasing redshift, such that only 30%-50% of the bulk of the present day red ellipticals was already in place at z {approx} 1.

79 ASTRONOMY AND ASTROPHYSICS↗

X-RAY AND NEAR-INFRARED OBSERVATIONS OF THE OBSCURED ACCRETING PULSAR IGR J18179-1621

IGR J18179-1621 is an obscured accreting X-ray pulsar discovered by INTEGRAL on 2012 February 29. We report on our 20 ks Chandra-High Energy Transmission Gratings Spectrometer observation of the source performed on 2012 March 17, on two short contemporaneous Swift observations, and on our two near-infrared (K{sub s} , H{sub n} , and J{sub n} ) observations performed on 2012 March 13 and 26. We determine the most accurate X-ray position of IGR J18179-1621, {alpha}{sub J2000} = 18{sup h}17{sup m}52.{sup s}18, {delta}{sub J2000} = -16 Degree-Sign 21'31.''68 (90% uncertainty of 0.''6). A strong periodic variability at 11.82 s is clearly detected in the Chandra data, confirming the pulsating nature of the source, with the light-curve softening at the pulse peak. The quasi-simultaneous Chandra-Swift spectra of IGR J18179-1621 can be well fit by a heavily absorbed hard power law (N{sub H} = 2.2 {+-} 0.3 Multiplication-Sign 10{sup 23} cm{sup -2} and photon index {Gamma} = 0.4 {+-} 0.1) with an average absorbed 2-8 keV flux of 1.4 Multiplication-Sign 10{sup -11} erg cm{sup -2} s{sup -1}. At the Chandra-based position, a source is detected in our near-infrared (NIR) maps with K{sub s} 13.14 {+-} 0.04 mag, H{sub n} = 16 {+-} 0.1 mag, and no J{sub n} -band counterpart down to {approx}18 mag. The NIR source, compatible with 2MASS J18175218-1621316, shows no variability between 2012 March 13 and 26. Searches of the UKIDSS database show similar NIR flux levels at epochs six months prior to and after a 2007 February 11 archival Chandra observation where the source's X-ray flux was at least 87 times fainter. In many ways IGR J18179-1621 is unusual: its combination of a several week long outburst (without evidence of repeated outbursts in the historical record), high absorption column (a large fraction of which is likely local to the system), and 11.82 s period does not fit neatly into existing X-ray binary categories.

79 ASTRONOMY AND ASTROPHYSICS↗

HJ-aggregates of donor–acceptor–donor oligomers and polymers

A vibronic exciton model is developed to account for the spectral signatures of HJ-aggregates of oligomers and polymers containing donor–acceptor–donor (DAD) repeat units. In (DAD) N π-stacks, J-aggregate-promoting intrachain interactions compete with H-aggregate promoting interchain interactions. The latter includes Coulombic coupling, which arises from “side-by-side” fragment transition dipole moments as well as intermolecular charge transfer (ICT), which is enhanced in geometries with substantial overlap between donors on one chain and acceptors on a neighboring chain. J-behavior is dominant in single (DAD)N chains with enhanced intrachain order as evidenced by an increased red-shift in the low-energy absorption band along with a heightened A 1 /A 2 peak ratio, where A 1 and A 2 are the oscillator strengths of the first two vibronic peaks in the progression sourced by the symmetric quinoidal–aromatic vibration. By contrast, the positive H-promoting interchain Coulomb interactions operative in aggregates cause the vibronic ratio to attenuate, similar to what has been established in H-aggregates of homopolymers such as P3HT. An attenuated A 1 /A 2 ratio can also be caused by H-promoting ICT which occurs when the electron and hole transfer integrals are out-of-phase. In this case, the A 1 peak is red-shifted, in contrast to conventional Kasha H-aggregates. With slight modifications, the ratio formula derived previously for P3HT aggregates is shown to apply to (DAD) N aggregates as well, allowing one to determine the effective free-exciton interchain coupling from the A 1 /A 2 ratio. Applications are made to polymers based on 2T-DPP-2T and 2T-BT-2T repeat units, where the importance of the admixture of the excited acceptor state in the lowest energy band is emphasized.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗