Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Characterization of SuperCDMS 1-inch Ge Detectors

The newly commissioned SuperCDMS Soudan experiment aims to search for WIMP dark matter with a sensitivity to cross sections of 5x10{sup -45}cm{sup 2} and larger (90% CL upper limit). This goal is facilitated by a new set of germanium detectors, 2.5 times more massive than the ones used in the CDMS-II experiment, and with a different athermal phonon sensor layout that eliminates radial degeneracy in position reconstruction of high radius events. We present characterization data on these detectors, as well as improved techniques for correcting position-dependent variations in pulse shape across the detector. These improvements provide surface-event discrimination sufficient for a reach of 5x10{sup -45}cm{sup 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomalous Thermal Behavior in Microcalorimeter Gamma-Ray Detectors

Improving the resolution of gamma-ray detectors is important for many fields, including determinations of the Lamb shift in atoms with high atomic numbers, nuclear treaty verification, and environmental monitoring. High-purity germanium detectors are currently the tool of choice for precision gamma-ray spectroscopy. The resolution of these detectors is limited to about 500 eV full-width-at-half-maximum at 100 keV by Fano statistics. In comparison, low-temperature microcalorimeters can provide over an order of magnitude improvement in photon resolution. For instance, a gamma-ray microcalorimeter has achieved 25 eV FWHM resolution at 103 keV. These calorimeters consist of two components, a bulk absorber to stop incident gamma rays and a thermometer made from a thin film electrically biased in the superconducting-to-normal phase transition, called a Transition Edge Sensor, or TES. The standard absorber is bulk, superconducting tin. While tin has historically been the best performing absorber, pulse decays in Sn devices are much slower than predicted. We have begun a systematic study of absorber behavior in order to assess and improve response times. This study leverages two capabilities: the ability to microfabricate highly uniform arrays of gamma-ray detectors and the ability to read out many detectors in a single cool-down using SQUID multiplexer circuits. Here, we present two experiments to identify the source of thermal time constants. The first involves varying properties of the Sn absorber including purity, vendor, and crystal grain size. The second examines the role of the other elements in the microcalorimeter assembly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EDELWEISS-II : status and first results

The EDELWEISS-II experiment is devoted to the direct detection of WIMP dark matter, using a new generation of cryogenic germanium detectors. We will present preliminary results of the first operation of these detectors installed in the Modane underground laboratory. Very low radioactive background conditions are achieved. Furthermore, these new detectors, with a special electrode design for active rejection of surface events, have been experimentally shown to be suited for WIMP searches with spin-independent scattering cross-sections on a nucleon well below 10{sup -8} pb. Preliminary results of WIMP searches performed with a first set of these detectors will be shown as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

STEADY COUNTERFLOW HE II HEAT TRANSFER THROUGH POROUS MEDIA

We present steady state counterflow measurements performed on porous samples saturated in He II. The experiment is composed of a vacuum insulated open channel whose top extremity is closed to a Minco registered heater. The temperature and pressure differences across the plug are measured by two germanium TTR-G Microsensors registered thermometers and a Validyne DP10-20 differential pressure sensor. Applied heat fluxes range up to 0.5 kW/m{sup 2} of sample cross section. Measurements were performed at temperatures ranging from 1.7 to 2.1 K on highly anisotropic samples provided by Composite Technology Development Inc.: circular pellets (3.08 mm thick and 28.58 mm in diameter) of 20 compressed layers of pre-impregnated woven magnet insulation. In the laminar regime, the permeability is estimated from the pressure drop measurements for comparison with room temperature data. In the turbulent regime, the model based on tortuosity developed previously fails to describe the heat transfer behavior of He II in this type of porous medium.

42 ENGINEERING↗

The puzzles of dark matter searches

Positive results of dark matter searches in DAMA/NaI and DAMA/LIBRA experiments, being put together with negative results of other groups, imply nontrivial particle physics solutions for cosmological dark matter. Stable particles with charge -2 bind with primordial helium in O-helium 'atoms' (OHe), representing a specific Warmer than Cold nuclear-interacting form of dark matter. Slowed down in the terrestrial matter, OHe is elusive for direct methods of underground Dark matter detection like those used in CDMS experiment, but its reactions with nuclei can lead to annual variations of energy release in the interval of energy 2-6 keV in DAMA/NaI and DAMA/LIBRA experiments. Schrodinger equation for system of nucleus and OHe is considered and reduced to an equation of relative motion in a spherically symmetrical potential well, formed by the Yukawa tail of nuclear scalar isoscalar attraction potential, acting on He beyond the nucleus, and dipole Coulomb repulsion between the nucleus and OHe at distances from the nuclear surface, smaller than the size of OHe. The values of coupling strength and mass of meson, mediating scalar isoscalar nuclear potential, are rather uncertain. Within these uncertainties we find a narrow window of these parameters, at which the sodium and/or iodine nuclei have a few keV binding energy with OHe. The concentration of OHe in the matter of underground detectors is adjusted to the incoming flux of cosmic O-helium at the timescale less than few minutes. Therefore the rate of radiative capture of Na and/or I by OHe should experience annual modulations. Transitions to more energetic levels of Na+OHe (I+OHe) system imply tunneling through dipole Coulomb barrier that leads to suppression of annual modulation of events with MeV-tens MeV energy release in the correspondence with the results of DAMA experiments. The proposed explanation inevitably leads to prediction of abundance of anomalous Na (and/or I) corresponding to the signal, observed by DAMA. At nuclear parameters, reproducing DAMA results, the energy release predicted for detectors with chemical content other than NaI differ in the most cases from the one in DAMA detector. In particular, it is shown that in the case of CDMS the energy of OHe-germanium bound state is beyond the range of 2-6 keV and its formation should not lead to ionization in the energy interval of DAMA signal.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photon Activation Analysis at the Idaho Accelerator Center

Activation methods require minimal sample preparation and provide sufficiently high sensitivity for detecting the vast majority of the elements throughout the periodic table. In this paper we shall discuss photon activation analysis (PAA) at the Idaho Accelerator Center. The process of PAA begins with exposing a sample with photons in the energy range of 10 to 30 MeV. Many nuclides in the sample will become activated and, in turn, these radionuclides will decay by emitting characteristic radiation. These characteristic radiation decays are the telltale signatures for identifying elements which can then be measured with spectrometers such as a high-purity Germanium detector. PAA is not an 'absolute' method, as the samples under investigation must be irradiated along with a reference or calibrating material having a well-known elemental composition. The quantitative evaluation is performed through comparing the two resulting element spectra from the unknown sample and reference material. Besides the obvious advantage of being non-destructive, PAA has minimal contamination issues. Moreover, materials that are difficult to treat chemically, such as certain refractory metals, dusts, ashes, etc., offer no hindrance to the technique of PAA. A further advantage is that PAA is very well suited for investigated minute samples (sub-milligram dust particles) to very large ones (in the multi-kg range). PAA is a robust technique as there are no real limitations concerning the nature of material to be studied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New developments in the diagnostics for the fusion products on JET in preparation for ITER (invited)

Notwithstanding the advances of the past decades, significant developments are still needed to satisfactorily diagnose ''burning plasmas.'' D-T plasmas indeed require a series of additional measurements for the optimization and control of the configuration: the 14 MeV neutrons, the isotopic composition of the main plasma, the helium ash, and the redistribution and losses of the alpha particles. Moreover a burning plasma environment is in general much more hostile for diagnostics than purely deuterium plasmas. Therefore, in addition to the development and refinement of new measuring techniques, technological advances are also indispensable for the proper characterization of the next generation of devices. On JET an integrated program of diagnostic developments, for JET future and in preparation for ITER, has been pursued and many new results are now available. In the field of neutron detection, the neutron spectra are now routinely measured in the energy range of 1-18 MeV by a time of flight spectrometer and they have allowed studying the effects of rf heating on the fast ions.A new analysis method for the interpretation of the neutron cameras measurements has been refined and applied to the data of the last trace tritium campaign (TTE). With regard to technological upgrades, chemical vapor deposition diamond detectors have been qualified both as neutron counters and as neutron spectrometers, with a potential energy resolution of about one percent. The in situ calibration of the neutron diagnostics, in preparation for the operation with the ITER-like wall, is also promoting important technological developments. With regard to the fast particles, for the first time the temperature of the fast particle tails has been obtained with a new high purity Germanium detector measuring the gamma emission spectrum from the plasma. The effects of toroidal Alfven eigenmodes modes and various MHD instabilities on the confinement of the fast particles have been determined with a combination of gamma ray cameras, neutral particle analyzers, scintillator probe, and Faraday cups. From a more technological perspective, various neutron filters have been tested to allow measurement of the gamma ray emission also at high level of neutron yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Astrophysically Important Reaction Rates For Novae And X-ray Bursts From Proton Breakup At Intermediate Energies

We discuss the use of one-nucleon removal reactions of loosely bound nuclei at intermediate energies as an indirect method in nuclear astrophysics. The breakup reactions are proved to be good spectroscopic tools and can be used to study a large number of loosely bound proton- or neutron-rich nuclei over a wide range of beam energies. As peripheral processes, they can be used to extract asymptotic normalization coefficients (ANCs) from which non-resonant capture reaction rates of astrophysical interest can be calculated parameter free. In this talk, we present results of a proton-breakup experiment carried out at GANIL (France) with a cocktail beam centered around {sup 23}Al at 50 MeV/nucleon. Momentum distributions of the breakup fragments, inclusive and in coincidence with gamma rays detected by EXOGAM Germanium clover array, were measured in the focal plan of SPEG energy-loss spectrometer. We present in particular the investigations of reaction rates for {sup 22}Mg(p,{gamma}){sup 23}Al and {sup 23}Al(p,{gamma}){sup 24}Si important for novae and X-ray bursts, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low Background Counting At SNOLAB

It is a continuous and ongoing effort to maintain radioactivity in materials and in the environment surrounding most underground experiments at very low levels. These low levels are required so that experiments can achieve the required detection sensitivities for the detection of low-energy neutrinos, searches for dark matter and neutrinoless double-beta decay. SNOLAB has several facilities which are used to determine these low background levels in the materials and the underground environment. This proceedings will describe the SNOLAB High Purity Germanium Detector which has been in continuous use for the past five years and give results of many of the items that have been counted over that period. Brief descriptions of SNOLAB's alpha-beta and electrostatic counters will be given, and the radon levels at SNOLAB will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low background physics at the Kimballton Mine

The Kimballton Underground Research Facility (KURF) is home to several experiments. One consists to two HPGe detectors designed to screen candidate materials to be used in low-background experiments for radioactivity. Analysis techniques, including our efficiency calculations will be presented. We have also deployed a customized BEGe (Broad Energy Germanium) detector in a low-background cryostat. This paper will focus on the shield design, detector characteristics and measurements that can be performed with such a detector in a low-background environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inelastic partial {gamma}-ray cross sections of {sup 150}Sm+n reactions for E{sub n} = 1-15 MeV

The {sup 150}Sm(n,n'{gamma}) reaction was measured from E{sub n} = 1 to 15 MeV at the Los Alamos Neutron Science Cemter (LANSCE). The {gamma} rays were detected with the Compton-suppressed Germanium Array for Neutron Induced Excitations (GEANIE). Measured {gamma}-ray excitation functions were converted to partial {gamma}-ray cross sections, Twenty four individual {gamma}-rays up to E{sub x} = 1.8 MeV in {sup 150}Sm were measured. Results are compared with enhanced Hauser Feshbach model calculations: the spin distribution in the pre-equilibrium reaction is calculated with the quantum mechanical model of Feshbach, Kerman and Koonin. The particle transmission coefficients were calculated with two different global optical model potential parameter sets. We employed the coupled-channel optical model based on the soft rotor model and with spherical potential.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-Ray Measurements Of A Thermo Scientific P385 DD Neutron Generator

Idaho National Laboratory is experimenting with electrical neutron generators, as potential replacements for californium-252 radioisotopic neutron sources in its PINS prompt gamma-ray neutron activation analysis (PGNAA) system for the identification of military chemical warfare agents and explosives. In addition to neutron output, we have recently measured the x-ray output of the Thermo Scientific P385 deuterium-deuterium neutron generator. X rays are a normal byproduct from neutron generators, but depending on their intensity and energy, x rays can interfere with gamma rays from the object under test, increase gamma-spectrometer dead time, and reduce PGNAA system throughput. The P385 x-ray energy spectrum was measured with a high-purity germanium (HPGe) detector, and a broad peak is evident at about 70 keV. To identify the source of the x rays within the neutron generator assembly, it was scanned by collimated scintillation detectors along its long axis. At the strongest x-ray emission points, the generator also was rotated 60 deg. between measurements. The scans show the primary source of x-ray emission from the P385 neutron generator is an area 60 mm from the neutron production target, in the vicinity of the ion source. Rotation of the neutron generator did not significantly alter the x-ray count rate, and its x-ray emission appears to be axially symmetric. A thin lead shield, 3.2 mm (1/8 inch) thick, reduced the 70-keV generator x rays to negligible levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-linear and unstable flux vortex dynamics.

Vortex dynamics in molybdenum-germanium superconducting films were found to well approximate the ideal unpinned free limit even at low driving forces. This provided a first opportunity to confirm the predictions of time-dependent Ginzburg Landau (TDGL) mean-field theory. At high driving forces the flux flow enters the classic Larkin-Ovchinnikov (LO) regime and the nonlinear current-voltage response can be well fitted to a hybrid TDGL-LO model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Short-wavelength and three-dimensional instability evolution in National Ignition Facility ignition capsule designs

Ignition capsule designs for the National Ignition Facility (NIF) [G. H. Miller, E. I. Moses, and C. R. Wuest, Opt. Eng. 443, 2841 (2004)] have continued to evolve in light of improved physical data inputs, improving simulation techniques, and, most recently, experimental data from a growing number of NIF sub-ignition experiments. This paper summarizes a number of recent changes to the cryogenic capsule design and some of our latest techniques in simulating its performance. Specifically, recent experimental results indicated harder x-ray drive spectra in NIF hohlraums than were predicted and used in previous capsule optimization studies. To accommodate this harder drive spectrum, a series of high-resolution 2-D simulations, resolving Legendre mode numbers as high as 2000, were run and the germanium dopant concentration and ablator shell thicknesses re-optimized accordingly. Simultaneously, the possibility of cooperative or nonlinear interaction between neighboring ablator surface defects has motivated a series of fully 3-D simulations run with the massively parallel HYDRA code. These last simulations include perturbations seeded on all capsule interfaces and can use actual measured shell surfaces as initial conditions. 3-D simulations resolving Legendre modes up to 200 on large capsule sectors have run through ignition and burn, and higher resolution simulations resolving as high as mode 1200 have been run to benchmark high-resolution 2-D runs. Finally, highly resolved 3-D simulations have also been run of the jet-type perturbation caused by the fill tube fitted to the capsule. These 3-D simulations compare well with the more typical 2-D simulations used in assessing the fill tube's impact on ignition. Coupled with the latest experimental inputs from NIF, our improving simulation capability yields a fuller and more accurate picture of NIF ignition capsule performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MUSETT and the Spectroscopy of Heavy Elements at GANIL

The new MUSETT silicon-wall has been built to study and obtain detailed spectroscopic information on the transfermium and transactinide elements. MUSETT is located at GANIL at the detection plane of VAMOS, the latter coupled with the EXOGAM germanium array. Results from the in-beam commissioning are reported and an overview of our future experimental program will be given.

43 PARTICLE ACCELERATORS↗

Modeling pulsed-laser melting of embedded semiconductor nanoparticles

Pulsed-laser melting (PLM) is commonly used to achieve a fast quench rate in both thin films and nanoparticles. A model for the size evolution during PLM of nanoparticles confined in a transparent matrix, such as those created by ion-beam synthesis, is presented. A self-consistent mean-field rate equations approach that has been used successfully to model ion beam synthesis of germanium nanoparticles in silica is extended to include the PLM process. The PLM model includes classical optical absorption, multiscale heat transport by both analytical and finite difference methods, and melting kinetics for confined nanoparticles. The treatment of nucleation and coarsening behavior developed for the ion beam synthesis model is modified to allow for a non-uniform temperature gradient and for interacting liquid and solid particles with different properties. The model allows prediction of the particle size distribution after PLM under various laser fluences, starting from any particle size distribution including as-implanted or annealed simulated samples. A route for narrowing the size distribution of embedded nanoparticles is suggested, with simulated distribution widths as low as 15% of the average size.

36 MATERIALS SCIENCE↗

Measurement of {nu}-bar{sub e}-e scattering cross section with CsI(Tl) detector array and the Beyond Standard Model constraints

A search of {nu}-bar{sub e}-e scattering cross section was carried out at the Kuo-Sheng nuclear power station. Based on 29882 and 7369 kg-days of reactor ON/OFF data, respectively, at an average reactor ON {nu}-bar{sub e} flux of 6.4x10{sup 12} cm{sup -2} s{sup -1}, the standard model (SM) electroweak interaction was probed at the squared 4-momentum transfer range of Q{sup 2}{approx}3x10{sup -6} GeV{sup 2}. The ratio of experimental to SM cross section was measured [1.08{+-}0.21(stat){+-}0.16(sys)]. We placed the constraints on the electroweak parameters (g{sub V},g{sub A}), corresponding to a weak mixing angle measurement of sin{sup 2}{theta}{sub W} = 0.251{+-}0.031(stat){+-}0.024(sys). A Point Contact Germanium Detector (PCGe) of mass 1 kg has been installed at a new underground laboratory 'China Jin-Ping Laboratory (CJPL)' in China.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of Naturally Occurring Radio Nuclides in Shir-kuh Granites

One of the principle natural radiation resources is Granite which can be dangerous for human because of its radiations. Based on this fact, in this research we attempt to specify the activity amount of these natural radio nuclides, existing in Shir-kuh Granite of Yazd state. To specify the activity amount of this natural radio nuclides, it has been applied the measurement method of Gamma spectroscopy using high purity Germanium (HPGe) detector.

54 ENVIRONMENTAL SCIENCES↗