Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Geothermal Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

The thermal regime of the Campi Flegrei magmatic system reconstructed through 3D numerical simulations

In this paper, we illustrate a quantitative conductive/convective thermal model incorporating a wide range of geophysical, petrological, geological, geochemical and isotopical observations that constrain the thermal evolution and present state of the Campi Flegrei caldera (CFc) magmatic system. The proposed model has been computed on the basis of the current knowledge of: (1) the volcanic and magmatic history of the volcano over the last 44 ka, (2) its underlying crustal structure, and (3) the physical properties of the erupted magmas. 3D numerical simulations of heat conduction and convection within heterogeneous rock/magma materials with evolving heat sources and boundary conditions that simulate magma rise from a deep (≥ 8 km depth) to shallow (2–6 km) reservoirs, magma chamber formation, magma extrusion, caldera collapse, and intra-caldera hydrothermal convection, have been carried out. The evolution of the CFc magmatic system through time has been simulated through different steps related to its changes in terms of depth, location and size of magma reservoirs and their replenishment. The thermal modeling results show that both heat conduction and convection have played an important role in the CFc thermal evolution, although with different timing. Finally, the simulated present heat distribution is in agreement with the measured geothermal profiles (Agip, 1987), reproduces the thermal gradient peaks at the CFc margins in correspondence to the anomalies in surface gradients (Corrado et al., 1998), and suggests temperatures of 700 °C at depth of 4 km in the central portion of the caldera, in agreement with the estimated temperature for the brittle-ductile transition (Hill, 1992).

3D conductive/convective model↗

SOI-Based High-Voltage, High-Temperature Integrated Circuit Gate Driver for SiC-Based Power FETs

Silicon carbide (SiC)-based field effect transistors (FETs) are gaining popularity as switching elements in power electronic circuits designed for high-temperature environments like hybrid electric vehicle, aircraft, well logging, geothermal power generation etc. Like any other power switches, SiC-based power devices also need gate driver circuits to interface them with the logic units. The placement of the gate driver circuit next to the power switch is optimal for minimizing system complexity. Successful operation of the gate driver circuit in a harsh environment, especially with minimal or no heat sink and without liquid cooling, can increase the power-to-volume ratio as well as the power-to-weight ratio for power conversion modules such as a DC-DC converter, inverter etc. A silicon-on-insulator (SOI)-based high-voltage, high-temperature integrated circuit (IC) gate driver for SiC power FETs has been designed and fabricated using a commercially available 0.8-m, 2-poly and 3-metal bipolar-complementary metal oxide semiconductor (CMOS)-double diffused metal oxide semiconductor (DMOS) process. The prototype circuit-s maximum gate drive supply can be 40-V with peak 2.3-A sourcing/sinking current driving capability. Owing to the wide driving range, this gate driver IC can be used to drive a wide variety of SiC FET switches (both normally OFF metal oxide semiconductor field effect transistor (MOSFET) and normally ON junction field effect transistor (JFET)). The switching frequency is 20-kHz and the duty cycle can be varied from 0 to 100-. The circuit has been successfully tested with SiC power MOSFETs and JFETs without any heat sink and cooling mechanism. During these tests, SiC switches were kept at room temperature and ambient temperature of the driver circuit was increased to 200-C. The circuit underwent numerous temperature cycles with negligible performance degradation.

33 ADVANCED PROPULSION SYSTEMS↗

Silicon-on-insulator-based high-voltage, high-temperature integrated circuit gate driver for silicon carbide-based power field effect transistors

Silicon carbide (SiC)-based field effect transistors (FETs) are gaining popularity as switching elements in power electronic circuits designed for high-temperature environments like hybrid electric vehicle, aircraft, well logging, geothermal power generation etc. Like any other power switches, SiC-based power devices also need gate driver circuits to interface them with the logic units. The placement of the gate driver circuit next to the power switch is optimal for minimising system complexity. Successful operation of the gate driver circuit in a harsh environment, especially with minimal or no heat sink and without liquid cooling, can increase the power-to-volume ratio as well as the power-to-weight ratio for power conversion modules such as a DC-DC converter, inverter etc. A silicon-on-insulator (SOI)-based high-voltage, high-temperature integrated circuit (IC) gate driver for SiC power FETs has been designed and fabricated using a commercially available 0.8--m, 2-poly and 3-metal bipolar-complementary metal oxide semiconductor (CMOS)-double diffused metal oxide semiconductor (DMOS) process. The prototype circuit-s maximum gate drive supply can be 40-V with peak 2.3-A sourcing/sinking current driving capability. Owing to the wide driving range, this gate driver IC can be used to drive a wide variety of SiC FET switches (both normally OFF metal oxide semiconductor field effect transistor (MOSFET) and normally ON junction field effect transistor (JFET)). The switching frequency is 20-kHz and the duty cycle can be varied from 0 to 100-. The circuit has been successfully tested with SiC power MOSFETs and JFETs without any heat sink and cooling mechanism. During these tests, SiC switches were kept at room temperature and ambient temperature of the driver circuit was increased to 200-C. The circuit underwent numerous temperature cycles with negligible performance degradation.

99 GENERAL AND MISCELLANEOUS↗

Field Test and Thermal Performance Comparison of a Novel Underground Thermal Battery with a Single U-tube Borehole Heat Exchanger for Geothermal Heat Pump Application

Geothermal Heat Pumps (GHP) are a proven technology to electrify and decarbonize space heating and cooling by utilizing the thermally consistent underground as a heat sink or source. However, the high drilling costs of conventional borehole heat exchangers (BHEs) associated with GHP systems and subsurface heterogeneity have been two major challenges to their widespread adoption. In this paper, we present results from a field-scale pilot of an Underground Thermal Battery (UTB) as a potential alternative to a conventional BHE. To benchmark the UTB performance, a side-by-side field test was conducted to compare the UTB with a conventional BHE installed at the same site. The UTB was installed in a 7.01-meter-deep borehole having a diameter of 0.9 meter, whereas the conventional BHE (with single U-tube loop) is in a borehole with 36.6-meter depth and 0.15-meter diameter. Both are integrated into a GHP system to meet the thermal energy demands of office space at the Illinois Energy Farm on the University of Illinois Urbana-Champaign campus. The system’s performance is compared in terms of heat transfer rate, outlet temperatures, and contributions to the overall thermal power of the GHP system under varying thermal demands and in different heat pump operation modes: heating only, cooling only, and hybrid (alternative, diurnal heating and cooling). Results to date indicate that the UTB delivers a more consistent response under during a time period of varying thermal demands. Its operational performance is better during short-term with higher thermal demands, while the conventional BHE performs better under continuous, long-term thermal demands.

Pokhrel, Sajjan [ORNL] (ORCID:0000000228523749)↗

Self-Healing Cements with Improved Toughness at Casing and Formation Interfaces for Subsurface Applications (CRADA 530)

Over the three-year CRADA, Pacific Northwest National Laboratory (PNNL) advanced a new class of Molecular Velcro™ self-healing wellbore cements designed to improve the long-term integrity of wells used for geothermal energy production and carbon storage. Conventional wellbore cement can crack due to repeated mechanical loading, temperature swings, and exposure to aggressive subsurface fluids. Once cracks form, they can create leakage pathways, drive expensive remediation (“workovers”), and in extreme cases shorten well life. This project addressed that problem by developing polymer-modified cement systems that can autonomously re-seal cracks and better tolerate the extreme conditions experienced in subsurface wells, while remaining compatible with practical cementing operations.

15 GEOTHERMAL ENERGY↗

An efficient optimization of well placement and control for a geothermal prospect under geological uncertainty

This work applies an efficient optimization technique based on a multivariate adaptive regression spline (MARS) technique to determine the optimal design and engineering of a potential geothermal production operation at a prospect near Superstition Mountain in Southern California, USA. The faster MARS-based statistical model is used as a surrogate for higher-fidelity physical models within the intensive optimization process. Its use allows for the exploration of the impacts of specific engineering design parameters in the context of geologic uncertainty as a means to both understand and maximize profitability of the production operation. The MARS model is initially developed from a training dataset generated by a finite set of computationally complex hydrothermal models applied to the prospect. Its application reveals that the optimal engineering design variables can differ considerably assuming different choices of hydrothermal flow properties, which, in turn, indicates the importance of reducing the uncertainty of key geologic properties. The major uncertainty sources in the natural-system are identified and ranked first by an efficient MARS-enabled total order sensitivity quantification, which is then used to assist evaluating the effect of geological uncertainties on optimized results. At the Southern California prospect, this parameter sensitivity analysis suggests that groundwater circulation through high permeable structures, rather than heat conduction through impermeable granite, is the primary heat transfer method during geothermal extraction. Reservoir histories simulated using optimal parameters with different constraints are analyzed and compared to investigate the longevity and maximum profit of the geothermal resources. The comparison shows that the longevity and profit are very likely to be overestimated by optimizations without appropriate constraints on natural conditions. In addition to geothermal energy production, this optimization approach can also be used to manage other geologic resource operations, such as hydrocarbon production or CO 2 sequestration, under uncertain reservoir conditions.

15 GEOTHERMAL ENERGY↗

From Fluid Flow to Coupled Processes in Fractured Rock: Recent Advances and New Frontiers

Abstract Quantitative predictions of natural and induced phenomena in fractured rock is one of the great challenges in the Earth and Energy Sciences with far‐reaching economic and environmental impacts. Fractures occupy a very small volume of a subsurface formation but often dominate fluid flow, solute transport and mechanical deformation behavior. They play a central role in CO 2 sequestration, nuclear waste disposal, hydrogen storage, geothermal energy production, nuclear nonproliferation, and hydrocarbon extraction. These applications require predictions of fracture‐dependent quantities of interest such as CO 2 leakage rate, hydrocarbon production, radionuclide plume migration, and seismicity; to be useful, these predictions must account for uncertainty inherent in subsurface systems. Here, we review recent advances in fractured rock research covering field‐ and laboratory‐scale experimentation, numerical simulations, and uncertainty quantification. We discuss how these have greatly improved the fundamental understanding of fractures and one's ability to predict flow and transport in fractured systems. Dedicated field sites provide quantitative measurements of fracture flow that can be used to identify dominant coupled processes and to validate models. Laboratory‐scale experiments fill critical knowledge gaps by providing direct observations and measurements of fracture geometry and flow under controlled conditions that cannot be obtained in the field. Physics‐based simulation of flow and transport provide a bridge in understanding between controlled simple laboratory experiments and the massively complex field‐scale fracture systems. Finally, we review the use of machine learning‐based emulators to rapidly investigate different fracture property scenarios and accelerate physics‐based models by orders of magnitude to enable uncertainty quantification and near real‐time analysis.

58 GEOSCIENCES↗

Foundation Heat Exchanger Final Report: Demonstration, Measured Performance, and Validated Model and Design Tool

Geothermal heat pumps, sometimes called ground-source heat pumps (GSHPs), have been proven capable of significantly reducing energy use and peak demand in buildings. Conventional equipment for controlling the temperature and humidity of a building, or supplying hot water and fresh outdoor air, must exchange energy (or heat) with the building's outdoor environment. Equipment using the ground as a heat source and heat sink consumes less non-renewable energy (electricity and fossil fuels) because the earth is cooler than outdoor air in summer and warmer in winter. The most important barrier to rapid growth of the GSHP industry is high first cost of GSHP systems to consumers. The most common GSHP system utilizes a closed-loop ground heat exchanger. This type of GSHP system can be used almost anywhere. There is reason to believe that reducing the cost of closed-loop systems is the strategy that would achieve the greatest energy savings with GSHP technology. The cost premium of closed-loop GSHP systems over conventional space conditioning and water heating systems is primarily associated with drilling boreholes or excavating trenches, installing vertical or horizontal ground heat exchangers, and backfilling the excavations. This project investigates reducing the cost of horizontal closed-loop ground heat exchangers by installing them in the construction excavations, augmented when necessary with additional trenches. This approach applies only to new construction of residential and light commercial buildings or additions to such buildings. In the business-as-usual scenario, construction excavations are not used for the horizontal ground heat exchanger (HGHX); instead the HGHX is installed entirely in trenches dug specifically for that purpose. The potential cost savings comes from using the construction excavations for the installation of ground heat exchangers, thereby minimizing the need and expense of digging additional trenches. The term foundation heat exchanger (FHX) has been coined to refer exclusively to ground heat exchangers installed in the overcut around the basement walls. The primary technical challenge undertaken by this project was the development and validation of energy performance models and design tools for FHX. In terms of performance modeling and design, ground heat exchangers in other construction excavations (e.g., utility trenches) are no different from conventional HGHX, and models and design tools for HGHX already exist. This project successfully developed and validated energy performance models and design tools so that FHX or hybrid FHX/HGHX systems can be engineered with confidence, enabling this technology to be applied in residential and light commercial buildings. The validated energy performance model also addresses and solves another problem, the longstanding inadequacy in the way ground-building thermal interaction is represented in building energy models, whether or not there is a ground heat exchanger nearby. Two side-by-side, three-level, unoccupied research houses with walkout basements, identical 3,700 ft{sup 2} floor plans, and hybrid FHX/HGHX systems were constructed to provide validation data sets for the energy performance model and design tool. The envelopes of both houses are very energy efficient and airtight, and the HERS ratings of the homes are 44 and 45 respectively. Both houses are mechanically ventilated with energy recovery ventilators, with space conditioning provided by water-to-air heat pumps with 2 ton nominal capacities. Separate water-to-water heat pumps with 1.5 ton nominal capacities were used for water heating. In these unoccupied research houses, human impact on energy use (hot water draw, etc.) is simulated to match the national average. At House 1 the hybrid FHX/HGHX system was installed in 300 linear feet of excavation, and 60% of that was construction excavation (needed to construct the home). At House 2 the hybrid FHX/HGHX system was installed in 360 feet of excavation, 50% of which was construction excavation. There are six pipes in all excavations (three parallel circuits - out and back), and the multiple instances of FHX and/or HGHX are all connected in series. The working fluid is 20% by weight propylene glycol in water. Model and design tool development was undertaken in parallel with constructing the houses, installing instrumentation, and monitoring performance for a year. Several detailed numerical models for FHX were developed as part of the project. Essentially the project team was searching for an energy performance model accurate enough to achieve project objectives while also having sufficient computational efficiency for practical use in EnergyPlus. A 3-dimensional, dual-coordinate-system, finite-volume model satisfied these criteria and was included in the October 2011 EnergyPlus Version 7 public release after being validated against measured data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utah FORGE GeoThermOPTIMAL Video

This is a project description video by Dr. William W. Fleckenstein related to their "Development of Multi-Stage Fracturing System and Wellbore Tractor to Enable Zonal Isolation During Stimulation and EGS Operations in Horizontal Wellbores" R&D project at Utah FORGE which is linked bellow.

15 GEOTHERMAL ENERGY↗

Application of the 226 Ra- 230 Th- 234 U and 227 Ac- 231 Pa- 235 U radiochronometers to UF 6 Cylinders

Uranium-series radiometric dating was performed on two well-pedigreed UF 6 cylinder samples containing highly enriched uranium that were in use at the Portsmouth Gaseous Diffusion Plant between the mid-1970s and mid-1980s. Daughter-parent (i.e. 231 Pa- 235 U, 230 Th- 234 U) radiometric ages determined on solid heel materials (e.g. UO 2 F 2 , UF 4 ) recovered from the emptied cylinders resulted in unrealistically old ages due to the preferential sequestration of progeny isotopes within the solid heels. However, limited elemental fractionation amongst the progeny isotopes themselves in the heel material allowed for useful age constraints on the fill dates of the UF6 cylinders to be extracted from the granddaughter-daughter systems (i.e. 226 Ra- 230 Th, 227 Ac- 231 Pa).

07 ISOTOPE AND RADIATION SOURCES↗

Hybridizing a geothermal power plant with concentrating solar power and thermal storage to increase power generation and dispatchability

Geothermal power plants often deploy less than their full power capacity due to declining geothermal resources. Integrating heat from a concentrating solar power (CSP) collector field increases the power output at low cost. This article considers five methods of solar heat addition in a double-flash geothermal plant. The most promising solution converts solar heat into electrical work with an efficiency of 24.3%. The economic feasibility and optimal sizing of the solar field and thermal stores are evaluated. A hybrid plant that increases power generation from 22 to 24 MWe has a Levelized Cost of Electricity (LCOE) of 0.07 +/- 0.01 $/kWhe. Adding three hours of storage increases the LCOE to 0.08 +/- 0.01 $/kWhe. Photovoltaic systems are considered to be a low-cost renewable technology, but an equivalent photovoltaic system with battery storage costs 0.15 +/- 0.07 $/kWhe due to the high cost and replacement rate of batteries compared to thermal storage. The hybrid plant also has a lower LCOE than a conventional CSP plant. If the dispatchability that thermal storage provides is rewarded with higher electricity prices, calculations indicate storage becomes an attractive investment when discharged power receives 1.75 times the typical price of electricity.

15 GEOTHERMAL ENERGY↗

WHOLESCALE: Seismic Survey Data from San Emidio Nevada 2021

This dataset includes raw and processed seismic data from the 2021 seismic survey at the San Emidio geothermal field in Nevada. In April and May 2021, 37 tri-axial short period seismographs were deployed in a 1.8km diameter cluster centered on 40.367278 N, 119.409019 W. The first data record started at 2021-04-06T07:09:10Z UTC and the last record ended at 2021-05-11T02:58:52Z UTC. The 37 stations included 29 SmartSolo IGU-16HR 3C all-in-one 5 Hz seismographs and 8 DataCube seismographs with 4.5 Hz HGS HG-6(B coil) tri-axial geophones. The raw format (level 0) data includes 353 GB of 500 sps SmartSolo data in native DLD format, 113 GB of 400 sps DataCube data in native DataCube format, and 3.4 GB of GPS data collected during the RTK GPS survey. The SAC data (level 1) files include 564 GB of hourly SAC files. The experiment was designed to monitor seismic activity before, during, and after the planned three-day plant maintenance shutdown April 19-21, 2021. The pumping stopped at 2021/04/19 12:51:45 UTC and resumed about 2021/04/21 21:00:00 UTC. The dataset is hosted in an AWS data lake, with an associated GDR data set providing the metadata. Links to both of these resources are included below. Additionally, this collection features data and metadata from a 2016 seismic survey at the same site for comparative analysis.

15 GEOTHERMAL ENERGY↗

WHOLESCALE: Seismic Survey Metadata from San Emidio Nevada 2021

This is a collection of metadata from the 2021 seismic survey at the San Emidio geothermal field in Nevada. In April and May 2021, 37 tri-axial short period seismographs were deployed in a 1.8km diameter cluster centered on 40.367278 deg N, 119.409019 deg W. The first data record started at 2021-04-06T07:09:10Z UTC and the last record ended 2021-05-11T02:58:52Z UTC. The 37 stations included 29 SmartSolo IGU-16HR 3C all-in-one 5 Hz seismographs and 8 DataCube seismographs with 4.5 Hz HGS HG-6(B coil) tri-axial geophones. The raw format (level 0) data includes 353 GB of 500 sps SmartSolo data in native DLD format, 113 GB of 400 sps DataCube data in native DataCube format, and 3.4 GB of GPS data collected during the RTK GPS survey. The SAC data (level 1) files include 564 GB of hourly SAC files. The experiment was designed to monitor seismic activity before, during, and after the planned three-day plant maintenance shutdown April 19-21, 2021. The pumping stopped at 2021/04/19 12:51:45 UTC and resumed about 2021/04/21 21:00:00 UTC. The raw and processed data are in an associated GDR submission, linked below. The metadata here includes files containing experiment details, station locations, seismic data logger specifications, instrumentation specifications, and descriptions of data. Also included are data and metadata from a 2016 seismic survey at the same site.

15 GEOTHERMAL ENERGY↗

Time Analysis on a Steam Condensation Jet

The time dependence of a steam bubble entering a water pool was measured for this experiment. The temperature of the water tank at the nozzle exit was 75 deg. C ± 5 deg. C. The experiment will focus on how the bubble changes its size through time for future experimental analysis concerning the heat transfer coefficient. The study focuses at different steam flow velocities approaching the water tank. The area of the steam bubble was measured using a high-speed camera to obtain the heat transfer coefficients. The region of interest is illuminated with a laser or a halogen lamp depending on the experiment. Calculating the rate at which the bubbles are created and condensed, will help obtain a better understanding of the energy transfer between the bubble and the water. The study of steam condensation is important due to its application on nuclear plants, heat exchangers, geothermal power plants and steam ejectors. Recently, more experiments have been performed and studied due to its high heat transfer rate. The results obtained in this experiment will be used to validate CFD models. This primary experimental report focuses on the steam bubble's time dependence; the same system will be used for future experiments concerning the heat transfer coefficient. In previous work done by Chun using only steam, the average heat transfer coefficient of direct contact condensation reported was in the range of 1.0-3.5 MW/m{sup 2} deg. C. He proposes an empirical correlation to predict the average heat transfer coefficients. The experimental data agrees with the empirical correlation within ± 30%. On a different experiment performed by Gulawani using a hot film anemometer on a steam condensation jet. The reported heat transfer coefficient for the vapor liquid interface varies between 0.1-4 MW/m{sup 2}-K. The nozzle diameter used during this experiment varied between 1-2 mm, and the velocity ranged between 286-304 m/s. Aya and Nariai reported three different heat transfer coefficients for direct contact condensation. They reported a heat transfer coefficient at chugging of 2*10{sup 6} W/m{sup 2}-K, at condensation oscillation of 10{sup 5} - 10{sup 6} W/m{sup 2}-K, and at the surface of stratified flow of 3*10{sup 3} - 3*10{sup 4} W/m{sup 2}-K. With steam and air mixture, a heat transfer coefficient relating the bubble average area was reported by Qu. He reported that the heat transfer coefficient decreased with the increase of the bubble diameter. The relation is time dependant and can be used to the transient analysis of the heat transfer. For this experiment, a set of images was obtained of a steam jet. The pictures were analyzed to obtained the time dependence of the steam bubble with time, and the rate of its condensation. A frequency of 20 Hz was calculated when the steam had a flow rate of 2.5 grams per second. The first result obtained for this experiment. In the future, more flow rates will be analyzed to obtain a relationship between the frequency of the bubbles and the flow rate of the steam. Eventually, this information will aid with the calculation of the heat transfer coefficient of the steam jet in a water pool.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Resource Characterization to Estimate Potential for Electricity Co-Production at Blackburn Oil Field, Nevada

The U.S. Department of Energy estimates that an annual average of 25 billion barrels of hot water are produced from oil and gas wells within the United States. The thermal energy available in the co-produced water stream is usually discarded, as the produced waters are considered an inconvenience by the operators and are disposed of using injection wells. However, utilizing organic Rankine cycle (ORC) generators, a vast amount of thermal energy can be captured and converted into electricity (albeit at relatively low efficiency due to the low temperatures). The National Renewable Energy Laboratory (NREL), in collaboration with Transitional Energy and Grant Canyon Oil & Gas, evaluated the feasibility of geothermal co-production of electricity by utilizing existing oil wells in Blackburn oil field in Nevada. The once prolific Blackburn oil field is located in Pine Valley, approximately 45 miles east-southeast of Elko, Nevada. Currently, the wells targeting the highly fractured Devonian Nevada dolomite reservoir are operating at a water cut ratio of more than 99%, with individual fluid (oil and water) production rates reaching 7.4 L/s (4,021 BBL/day). Analysis of publicly available data showed that the combination of the suitable wells' maximum historical production rates reached 22.90 L/s. The production from these wells occurs naturally and the wells are choked (and even shut down) by the operator to mitigate excessive water production, indicating a strong reservoir recharge and future opportunity to increase the water production for geothermal electricity generation. The main goal of this study was to evaluate the productivity of the existing wells, the performance of the reservoir, the surface network, and the operational constraints in order to achieve 1 MWe of electricity production from the field's water production. Utilizing the GEOPHIRES tool, we have determined that a twofold to threefold increase in the total fluid production, compared to the historical production under artificial restraint (choke), is required to reach a 1-MWe net target output for a low-temperature ORC system with air-cooled condensers. Lower flow rates would be required when utilizing water-based condensers instead of air-cooled condensers. However, that would require a constant supply of cold water, which may be challenging given the arid environment of the project site.

Blackburn↗

Lab on a chip for a low-carbon future

Transitioning our society to a sustainable future, with low or net-zero carbon emissions to the atmosphere, will require a wide-spread transformation of energy and environmental technologies. In this perspective article, we describe how lab-on-a-chip (LoC) systems can help address this challenge by providing insight into the fundamental physical and geochemical processes underlying new technologies critical to this transition, and developing the new processes and materials required. We focus on six areas: (I) subsurface carbon sequestration, (II) subsurface hydrogen storage, (III) geothermal energy extraction, (IV) bioenergy, (V) recovering critical materials, and (VI) water filtration and remediation. Here, we hope to engage the LoC community in the many opportunities within the transition ahead, and highlight the potential of LoC approaches to the broader community of researchers, industry experts, and policy makers working toward a low-carbon future.

42 ENGINEERING↗

Underwater plasma breakdown characteristics with respect to highly pressurized drilling applications

Deep earth drilling is a key technique to extract oil, gas, and geothermal heat from the earth. Many complex energy focusing methods have been explored as an alternative approach to reach these resources but most of them require high energy. However, by utilizing short time span liquid plasma discharges, energy focusing can be achieved within traditional drilling systems. These discharges induce a rapid expansion process and a resulting shockwave. It is believed that this focused energy will lower the required cutting force to progress through the rock. Lowering the required cutting force will allow for lower drill bit wear, quicker rate of penetration, and an overall cost savings of the project. Plasma breakdown characteristics at drilling relevant pressures, ranging from 1 to 350 atm, were studied. A resistance–capacitance circuit with an air gapped spark switch was utilized to generate pulsed plasma between the pressurized electrodes. It was found that the required breakdown voltage increases as the pressure increases. It was also found that a plasma channel formation and an associated breakdown may or may not occur between the electrodes at different pressures due to variation in required breakdown voltages. Breakdown time-lag in the dielectric medium (tap water, 780 μS cm –1 ) increased as the pressure was increased, which indicated a higher voltage drop at higher pressures (>100 atm). The plasma generated cavitation bubble with an associated shockwave occurred as pressures were increased. However, the bubble radius and the bubble duration decreased as the pressure was increased. The plasma generated shockwave speeds fall within the expected speed of sound in water. Lastly, preliminary rock cracking tests were performed on granite at high pressures (340 and 272 atm) and it was found that plasma is able to create cracks in the rock.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hawaii Play Fairway Analysis: Oahu Groundwater Flow Model

Groundwater flow model for the island of Oahu. Data is from the following sources: Rotzoll, K., A.I. El-Kadi. 2007. Numerical Ground-Water Flow Simulation for Red Hill Fuel Storage Facilities, NAVFAC Pacific, Oahu, Hawaii - Prepared TEC, Inc. Water Resources Research Center, University of Hawaii, Honolulu.; Whittier, R.B., K. Rotzoll, S. Dhal, A.I. El-Kadi, C. Ray, G. Chen, and D. Chang. 2004. Hawaii Source Water Assessment Program Report - Volume VII - Island of Oahu Source Water Assessment Program Report. Prepared for the Hawaii Department of Health, Safe Drinking Water Branch. University of Hawaii, Water Resources Research Center. Updated 2008.; and Whittier, R. and A.I. El-Kadi. 2009. Human and Environmental Risk Ranking of Onsite Sewage Disposal Systems - Final. Prepared by the University of Hawaii, Dept. of Geology and Geophysics for the State of Hawaii Dept. of Health, Safe Drinking Water Branch. December 2009.

15 GEOTHERMAL ENERGY↗