Echo-enabled Harmonic Generation Free Electron Laser

In this paper, we systematically study the echo-enabled harmonic generation (EEHG) free electron laser (FEL). The EEHG FEL uses two modulators in combination with two dispersion sections that allow to generate in the beam a high harmonic density modulation starting with a relatively small initial energy modulation of the beam. After presenting analytical theory of the phenomenon, we address several practically important issues, such as the effect of incoherent synchrotron radiation in the dispersion sections, and the beam transverse size effect in the modulator. Using a representative realistic set of beam parameters, we show how the EEHG scheme enhances the FEL performance and allows to generate a fully (both longitudinally and transversely) coherent radiation. As an example, we demonstrate that 5 nm coherent soft x-rays with GW peak power can be generated directly from the 240 nm seeding laser using the proposed EEHG scheme.

43 PARTICLE ACCELERATORS↗

Toward a fully coherent tender and hard X-ray free-electron laser via cascaded EEHG in fourth-generation synchrotron light sources

Free-electron-laser-based beamlines utilize fully coherent laser pulses with extremely narrow bandwidth allowing direct use of X-rays without monochromators. This could be very beneficial for all users of current and future fourth-generation diffraction-limited synchrotron light sources (DL-SLSs) who need narrowband full-coherence high-brightness X-ray pulses. Based on our previous finding, i.e. that separating the two stages of echo-enabled harmonic generation (EEHG) with a few extra bending-magnet sections provides an effective way to increase the momentum compaction of chicane 1, one can simultaneously achieve adequate prebunching at extremely high harmonics as well as keep the energy modulation to the ideal minimum. This could open the door for cascaded EEHG, toward fully coherent tender and hard X-ray wavelengths. Built on our compact design of a twin-pulse seeding electron beam with an adjustable delay and timing jitter at the level of a few femtoseconds, a cascaded EEHG can be implemented, which includes two EEHG beamlines, where the radiation pulse generated by the first beamline with harmonic $h$ 1 could be used as the input seed laser pulse to the second beamline with harmonic $h$ 2 . Hence, the second radiator could potentially reach very high harmonics [$h$ = $h$ 1 (20)$h$ 2 (25–100)] from 500 to 2000, corresponding to tender and hard X-ray wavelengths. It is demonstrated that the cascaded EEHG scheme is compatible with almost any current or planned fourth-generation DL-SLS, with significant benefits for space-limited storage rings in particular. The main advantage is that this scheme requires almost no change of the storage-ring lattice and is fully compatible with other beamlines. Current proposals for rings with much longer straight sections would add self-amplified spontaneous emission as another viable option for storage-ring-based free-electron lasers.

36 MATERIALS SCIENCE↗

Objective PDF-Shaping-Based Economic Dispatch for Power Systems with Intermittent Generation Sources via Simultaneous Mean and Variance Minimization

With the ever increased penetration of renewables in power grid, economic power dispatch faces a challenge in terms of min-imizing the generation cost which is increasingly affected by random factors and constraints subjected to random inputs. In this context, the cost functions are random for which the widely used mean value based minimization can only achieve limited profit gain. Indeed, as the probability density function (PDF) is a comprehensive measure of characteristics of any random varia-bles, the desired optimization should address the shaping of the PDF of the generation cost function rather just its mean value. Through a simple case study, this paper firstly reveals the long tail PDF shape of the cost function when the traditional mean-value based optimization is used. This is then followed by the de-velopment of a novel PDF-shaping-based method that optimizes both the mean and variance of the PDF of the cost function. It has been shown that the proposed approach can reshape the PDF of the generation cost function so as to make it as left and as narrow as possible, leading to a significant low risk for high generation cost. Simulation tests have been included to show the effectiveness of the proposed approach and encouraging results have been obtained.

intermittent generation sources, uncertainties, PD↗

Modeling Imperfect Generator Behavior in Power System Operation Models

A key component in power system operations is the use of computer models to quickly study and analyze different operating conditions and futures in an efficient manner. The output of these models are sensitive to the data used in them as well as the assumptions made during their execution. One typical assumption is that generators and load assets perfectly follow operator control signals. While this is a valid simulation assumption, generators may not always accurately follow control signals. This imperfect response of generators could impact cost and reliability metrics. This paper proposes a generator model that capture this imperfect behavior and examines its impact on production costs and reliability metrics using a steady-state power system operations model. Preliminary analysis shows that while costs remain relatively unchanged, there could be significant impacts on reliability metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimation of Behind-the-Meter Solar Generation by Integrating Physical with Statistical Models

Accurate estimation of solar photovoltaic (PV) generation is crucial for distribution grid control and optimization. Unfortunately, most of the residential solar PV installations are behind-the-meter. Thus, utilities only have access to the net load readings. This paper presents an unsupervised framework for estimating solar PV generation by disaggregating the net load readings. The proposed framework synergistically combines a physical PV system performance model with a statistical model for load estimation. Specifically, our algorithm iteratively estimates solar PV generation with a physical model and electric load with the Hidden Markov model regression. The proposed algorithm is also capable of estimating the key technical parameters of the solar PV systems. Our proposed method is validated against net load and solar PV generation data gathered from residential customers located in Austin, Texas. The validation results show that our method reduces mean squared error by 44% compared to the state-of-the-art disaggregation algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Benchmarking the Suitability of Novec$^{\mathrm{TM}}$ 4710 for Application in Flux Compression Generators

Here, an experimental study evaluated the feasibility of replacing traditional insulating gases such as SF 6 with C 4 F 7 N (3M TM , Novec 4710) in flux compression generator (FCG) applications. Currently available data indicate that Novec 4710 could offer certain performance benefits over SF 6 . However, the available literature is focused on low frequency (50–60 Hz) and dc at static pressures. To evaluate the performance of Novec 4710 under the pulsed dynamic pressure and temperature conditions found in an FCG, we report a performance comparison between three sets of identical FCGs using air, SF 6 , and Novec 4710 as the insulating gas. The generators used in this study had a single stage, directly seeded design with an armature diameter of 25 mm and a stator diameter of 46 mm. To highlight the performance of the different gases rather than any wire insulation, the stator was constructed with uninsulated wire. Furthermore, the generators were seeded aggressively, making the performance difference between the different gases more apparent. The performance was monitored with a pair of differential Rogowski coils that captured the generators’ di / dt while also using high-speed videography to capture possible gaseous breakdown signatures. The data gathered during this study indicate that Novec 4710 performs at least as well as SF 6 in FCG applications, if not significantly better.

42 ENGINEERING↗

Unit Commitment With Continuous-Time Generation and Ramping Trajectory Models

There is increasing evidence of shortage of ramping resources in the real-time operation of power systems. To explain and remedy this problem systematically, we take a novel look at the way the day-ahead unit commitment (UC) problem represents the information about load, generation and ramping constraints. We specifically investigate the approximation error made in mapping of the original problem, that would decide the continuous-time generation and ramping trajectories of the committed generating units, onto the discrete-time problem that is solved in practice. We first show that current practice amounts to approximating the trajectories with linear splines. We then offer a different representation through cubic splines that provides physically feasible schedules and increases the accuracy of the continuous-time generation and ramping trajectories by capturing sub-hourly variations and ramping of load in the day-ahead power system operation. The corresponding day-ahead UC model is formulated as an instance of mixed-integer linear programming (MILP), with the same number of binary variables as the traditional UC formulation. Numerical simulation over real load data from the California ISO demonstrate that the proposed UC model reduces the total day-ahead and real-time operation cost, and the number of events of ramping scarcity in the real-time operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Flexible Operation of Distributed Generation in Distribution Networks With Dynamic Boundaries

Distributed generators performing black start to form isolated microgrids offer a flexible and resilient solution to service restoration in distribution systems. Employing the dynamic microgrid concept, distributed generators can form isolated microgrids by changing their physical boundaries through smart switches and conventional circuit breakers. However, the flexibility of distributed generators has not been thoroughly investigated and utilised in existing works. To address this issue, this letter presents a new model to the reconfiguration formulation in active distribution networks considering different operation modes of distributed generators. Compared with the existing models, this study provides a new formulation supporting different DGs' operation modes and fully making use of their flexibility. Illustrative results on IEEE 34-test systems verify the effectiveness of the proposed model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Examining the Economic Optimality of Automatic Generation Control

The automatic generation control (AGC) system is temporally situated between economic dispatch and synchronous generator dynamics, and its primary role is to regulate frequency within and tie-line flows between control areas. Given appropriate choice of participation factors (feed-forward controller gains that govern the disaggregation of the area-level power requirement to individual generators), the AGC can be engineered to nudge system dynamics toward a steady-state operating point corresponding to economic optimality. This paper establishes necessary and sufficient conditions under which a widely accepted choice of participation factors guarantees the alignment of steady-state synchronous generator outputs with a global minimum of a prototypical economic dispatch problem. In so doing, it resolves several ambiguities and formalizes technical assumptions governing the role of the standard AGC architecture in the context of economic dispatch and steady-state operation. Numerical case studies tailored to a modified version of the New England 39-bus 10-machine test system validate the theoretical results.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analyzing Gas Turbine-Generator Performance of the Hybrid Power System

We report kinetic energy available from the turbomachinery may boost short-term ramp rates during load shifting between generator and fuel cell that may be exploited to optimize the performance of turbine-fuel cell hybrid systems during load following. The paper starts with modeling a gas turbine, gearbox, and generator sitting on the rigid shafts as a two-mass model primarily for estimating the rotational inertia available from the turbogenerator. The gas turbine and its environment impose constraints of available space allowances, measurements from high-speed rotating parts, lack of accessibility to the shaft of measure, making replacements and/or required installation adjustments of the torque transducer difficult. It is demonstrated that in the absence of torque measurement, the data containing only a slow excursion of the rotor motion in response to a slight load change is sufficient to determine inertia and damping coefficients from the model. Furthermore, the generator’s reactive power capability was investigated because it serves as an asset in integrated hybrid systems to meet dynamic reactive power demands, reducing the burden on the fuel cell’s power electronics control in generating reactive power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Recent Trends in Variable Generation Forecasting and Its Value to the Power System

We report that the rapid deployment of wind and solar energy generation systems has resulted in a need to better understand, predict, and manage variable generation. The uncertainty around wind and solar power forecasts is still viewed by the power industry as being quite high, and many barriers to forecast adoption by power system operators still remain. In response, the U.S. Department of Energy has sponsored, in partnership with the National Oceanic and Atmospheric Administration, public, private, and academic organizations, two projects to advance wind and solar power forecasts. Additionally, several utilities and grid operators have recognized the value of adopting variable generation forecasting and have taken great strides to enhance their usage of forecasting. In parallel, power system markets and operations are evolving to integrate greater amounts of variable generation. This paper will discuss the recent trends in wind and solar power forecasting technologies in the U.S., the role of forecasting in an evolving power system framework, and the benefits to intended forecast users.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Endogenous Assessment of the Capacity Value of Solar PV in Generation Investment Planning Studies

There exist several different reliability-and approximation-based methods to determine the contribution of solar resources toward resource adequacy. However, most of these approaches require knowing in advance the installed capacities of both conventional and solar generators. This is a complication since generator capacities are actually decision variables in capacity planning studies. In this paper, we study the effect of time resolution and solar PV penetration using a planning model that accounts for the full distribution of generator outages and solar resource variability. We also describe a modification of a standard deterministic planning model that enforces a resource adequacy target through a reserve margin constraint. Our numerical experiments show that at least 50 days worth of data are necessary to approximate the results of the full-resolution model with a maximum error of 2.5% on costs and capacity. We also show that the amount of displaced capacity of conventional generation decreases rapidly as the penetration of solar PV increases. We find that using an exogenously defined and constant capacity value based on time-series data can yield relatively accurate results for small penetration levels. For higher penetration levels, the modified deterministic planning model better captures avoided costs and the decreasing value of solar PV.

14 SOLAR ENERGY↗

Multi-Time Scale Coordinated Control and Scheduling of Inverter-Based TCLs With Variable Wind Generation

To address microgrid tie flow errors caused by wind generation variability, here we propose and develop a multi-time scale coordinated control and scheduling strategy for inverter-based thermostatically controlled loads (TCLs). First, in hour-time scale, inverter-based TCLs with adjusting temperature set-point are modeled as virtual generators to compensate tie flow deviations in the day-ahead plan. Next, in minute-time scale, virtual batteries representing operating behaviors of inverter-based TCLs with frequency control are scheduled determined by the control of virtual generators in hour-time scale. The virtual batteries are scheduled to smooth out tie flow errors corresponding to day-ahead plan and hour-time scale schedules. The multi-time scale control methods are coordinated to employ the response potential of inverter-based TCLs and response curve-based methods are proposed to control inverter-based TCLs considering the customer privacy. The multi-time scale stochastic schedules which are based on response curves of inverter-based TCLs are coordinated to accommodate wind generation variability. Simulation results demonstrate that the microgrid tie flow errors are effectively mitigated by the proposed multi-time scale coordinated control and scheduling of inverter-based TCLs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Fast Flexibility-Driven Generation Portfolio Planning Method for Sustainable Power Systems

We are witnessing an acceleration in the uptake of renewable energy in power systems. Because of the associated variability and uncertainty of renewables, power systems need to have an adequate supply of flexibility to allow for suitable management of short-term operations. So far most of the work in this area has neglected how flexibility needs associated with renewables are fulfilled as part of dispatchable generation capital investments decisions. To address this challenge, we propose an approach to plan the dispatchable generation mix of a power system as needed to counteract variability and uncertainty associated with significant shares of variable renewable generation. The approach exploits the linear time-invariant feature of variable generation variability using historical phase planes of capacity (in MW) and ramp (in MW/min) to bridge the gap between long-term capacity planning and short-term intra-hour flexibility needs. This approach is much more computationally tractable than other proposals, while also being able to capture adequately short-term operational features like ramping and net load variability. Numerical tests are performed on realistic datasets to substantiate the effectiveness of the approach.

bulk power system planning↗

Joint Estimation of Behind-the-Meter Solar Generation in a Community

Distribution grid planning, control, and optimization require accurate estimation of solar photovoltaic (PV) generation and electric load in the system. Most of the small residential solar PV systems are installed behind-the-meter making only the net load readings available to the utilities. This paper presents an unsupervised framework for joint disaggregation of the net load readings of a group of customers into the solar PV generation and electric load. Our algorithm synergistically combines a physical PV system performance model for individual solar PV generation estimation with a statistical model for joint load estimation. The electric loads for a group of customers are estimated jointly by a mixed hidden Markov model (MHMM) which enables modeling the general load consumption behavior present in all customers while acknowledging the individual differences. At the same time, the model can capture the change in load patterns over a time period by the hidden Markov states. The proposed algorithm is also capable of estimating the key technical parameters of the solar PV systems. Our proposed method is evaluated using the net load, electric load, and solar PV generation data gathered from residential customers located in Austin, Texas. Testing results show that our proposed method reduces the mean squared error of state-of-the-art net-load disaggregation algorithms by 67%.

behind-the-meter solar generation↗

SU-E-T-21: A D-D Based Neutron Generator System for Boron Neutron Capture Therapy: A Feasibility Study

Purpose: To investigate the feasibility of a deuterium-deuterium (DD) neutron generator for application in boron neutron capture therapy (BNCT) of brain cancer Methods: MCNP simulations were performed using a head phantom and a monoenergetic neutron source, which resembles the point source in a DD generator that emits 2.45-MeV neutrons. Source energies ranging from 5eV to 2.45MeV were simulated to determine the optimal treatment energy. The phantom consisted of soft tissue, brain tissue, skull, skin layer, and a brain tumor of 5 cm in diameter. Tumor depth was varied from 5–10 cm. Boron-10 concentrations of 10 ppm, 15 ppm, and 30 ppm were used in the soft/brain tissues, skin, and tumor, respectively. The neutron flux required to deliver 60 Gy to the tumor as well as the normal tissue doses were determined. Results: Beam energies between 5eV and 10keV obtained doses with the highest dose ratios (3.3–25.9) between the tumor and the brain at various depths. The dose ratio with 2.45-MeV neutrons ranged from 0.8–6.6. To achieve the desired tumor dose in 40 minutes, the required neutron flux for a DD generator was between 8.8E10 and 5.2E11 n/s and the resulting brain dose was between 2.3 and 18 Gy, depending on the tumor depth. The skin and soft tissue doses were within acceptable tolerances. The boron-neutron interaction accounted for 54–58% of the total dose. Conclusion: This study shows that the DD neutron generator can be a feasible neutron source for BNCT. The required neutron flux for treatment is achievable with the current DD neutron technology. With a well-designed beam shaping assembly and treatment geometry, the neutron flux can be further improved and a 60-Gy prescription can be accurately delivered to the target while maintaining tolerable normal tissue doses. Further experimental studies will be developed and conducted to validate the simulation results.

60 APPLIED LIFE SCIENCES↗

TermGenie – a web-application for pattern-based ontology class generation

Biological ontologies are continually growing and improving from requests for new classes (terms) by biocurators. These ontology requests can frequently create bottlenecks in the biocuration process, as ontology developers struggle to keep up, while manually processing these requests and create classes. TermGenie allows biocurators to generate new classes based on formally specified design patterns or templates. The system is web-based and can be accessed by any authorized curator through a web browser. Automated rules and reasoning engines are used to ensure validity, uniqueness and relationship to pre-existing classes. In the last 4 years the Gene Ontology TermGenie generated 4715 new classes, about 51.4% of all new classes created. The immediate generation of permanent identifiers proved not to be an issue with only 70 (1.4%) obsoleted classes. Lastly, TermGenie is a web-based class-generation system that complements traditional ontology development tools. All classes added through pre-defined templates are guaranteed to have OWL equivalence axioms that are used for automatic classification and in some cases inter-ontology linkage. At the same time, the system is simple and intuitive and can be used by most biocurators without extensive training.

97 MATHEMATICS AND COMPUTING↗

Review of Operational Water Consumption and Withdrawal Factors for Electricity Generating Technologies

Various studies have attempted to consolidate published estimates of water use impacts of electricity generating technologies, resulting in a wide range of technologies and values based on different primary sources of literature. The goal of this work is to consolidate the various primary literature estimates of water use during the generation of electricity by conventional and renewableelectricity generating technologies in the United States to more completely convey the variability and uncertainty associated with water use in electricity generating technologies.

13 HYDRO ENERGY↗