X-ray Computed Tomography as a Metrology Technique for the Analysis of Additively Manufactured Material

X-ray computed tomography (X-ray CT) is an analytical technique used in materials science to non-destructively characterize features in a variety materials like polymer, metals, composites, and explosives. It also has the capability of imaging additively manufacture, machine and assembled parts. The non-destructive imaging allows for the analysis of features (voids and cracks), which give a fundamental understanding of the material characteristics. Additionally, X-ray CT can obtain accurate measurements of dimensional and topographic variations due to different stimuli and assess the accuracy of material production. This study focuses on parts manufactured via metal additive manufacturing (AM). Although AM produces parts faster and easier, the printing process can produce defects (pores and surface roughness) that undermine the part’s mechanical properties and performance. The analysis of 3D printed objects has an asset in that the material has an STL file from which the item was printed, which is not available in many manufactured materials (i.e., foams) due to stochastic structures. For this study, the print accuracy of four additively manufactured cylinders will be assessed via X-ray CTto approximate the surface roughness and visualize any major morphological changes to assess the dimensional accuracy of complex additively manufactured parts. It was concluded that using X-ray CT to measure surface roughness was affective because reasonable surface roughness values were measured. Additionally, itwas determined that small-scale features can be produced via additive manufacturing with strong dimensional accuracy so long as the features are highly complex with sharp grooves.

36 MATERIALS SCIENCE↗

Molten Salt Corrosion Tests of Additively Manufactured Stainless Steel 316H

Molten salt reactors (MSRs) have drawn considerable interest due to their favorable safety features, high thermal efficiency, and compatibility with different fuel cycles. Yet, the success of MSRs hinges critically on the performance of structural materials to be used in these aggressive molten salt environments, where corrosion and material compatibility remain primary challenges to long-term reliability. Additively manufactured (AM) nuclear structural materials prompt the use of novel geometries and compositions to enhance material performance and reduce costs of constructing MSRs. The rapid solidification conditions inherent to AM processing impart distinctive microstructural features, including cellular sub-structures, dislocation densities, residual stress, and oxide inclusions, which can influence material performance in MSR components. While the mechanical properties of AM stainless steels have been widely studied, their corrosion behavior, particularly in molten salt environments, has received far less attention. Addressing these needs, the Advanced Materials and Manufacturing Technologies (AMMT) program provides a framework for systematically evaluating how unique microstructures produced by AM processes influence the performance of these materials in these demanding environments and for developing reproducible testing workflows that can support future code qualification efforts and standards development. Bridging this knowledge gap is essential for assessing the viability of AM alloys in MSRs and informing qualification strategies. A further challenge is the absence of standardized protocols for molten salt corrosion testing. Accordingly, this report provides an account of the corrosion evaluation of AM 316H stainless steel in NaCl 2 -MgCl 2 molten salt at 550 °C, with exposure times of 100 and 500 hours. It documents the experimental procedures implemented under the AMMT program, including salt preparation, exposure protocols, and post-test characterization methods, to establish reproducibility and transparency. Importantly, the study examines AM 316H samples in the as-fabricated condition, directly reflecting the surface state most relevant to engineering applications, and compares their behavior to machine-cut surfaces. Overall, preliminary evaluations have noted that surface conditions (e.g. morphology, contamination, etc.) have a noticeable impact on the corrosion resiliency. The impact of the corrosion is difficult to detect at 100h, unless, in the case of AM 316H, the specimen surface is decontaminated. After 500 h, as-fabricated surfaces of AM and wrought 316H display evidence of general versus preferential corrosion attack, respectively. Both AM and wrought 316H machine-cut surfaces exhibit a continuous Cr depletion zone, evident of general corrosion. While the estimated extent of corrosion appears within the same order of magnitude regardless of the surface condition, it is apparent that more predictable behavior is observed on machine-cut surfaces. Nonetheless, further investigation is necessary to fully elucidate the corrosion mechanism under these conditions.

36 - MATERIALS SCIENCE↗

DisasterAWARE – A Global Alerting Platform for Flood Events

The rising number of flooding events combined with increased urbanization is contributing to significant economic losses due to damages to structures and infrastructures. From a risk reduction and resilience perspective, it is not only essential to forecast flood risk and potential impacts, but also to disseminate the information to stakeholders on the ground for rapid implementation of mitigation and response measures. This paper provides (i) an introduction to DisasterAWARE®, a global alerting system, that is used to disseminate flood risk information to stakeholders across the globe, and (ii) a discussion of the models implemented using earth observation data (Synthetic Aperture Radar and optical imagery) for near real-time assessment of flood severity and potential flood impacts to infrastructures. While the models are still in their nascent stage, a case study implementation of the models for the 2020 flooding event in Africa is presented to showcase the model integration with DisasterAWARE®.

54 ENVIRONMENTAL SCIENCES↗

Biology-inspired Architecture for Situation Management

Situation Management is a rapidly developing science combining new techniques for data collection with advanced methods of data fusion to facilitate the process leading to correct decisions prescribing action. Current research focuses on reducing increasing amounts of diverse data to knowledge used by decision makers and on reducing time between observations, decisions and actions. No new technology is more promising for increasing the diversity and fidelity of observations than sensor networks. However, current research on sensor networks concentrates on a centralized network architecture. We believe this trend will not realize the full potential of situation management. We propose a new architecture modeled after biological ecosystems where motes are autonomous and intelligent, yet cooperate with local neighborhoods. Providing a layered approach, they sense and act independently when possible, and cooperate with neighborhoods when necessary. The combination of their local actions results in global effects. While situation management research is currently dominated by military applications, advances envisioned for industrial and business applications have similar requirements. NASA has requirements for intelligent and autonomous systems in future missions that can benefit from advances in situation management. We describe requirements for the Integrated Vehicle Health Management program where our biology-inspired architecture provides a layered approach and decisions can be made at the proper level to improve safety, reduce costs, and improve efficiency in making diagnostic and prognostic assessments of the structural integrity, aerodynamic characteristics, and operation of aircraft.

Jones, Kennie H.↗

Rich-Text based PSA Model Transformation and Verification in RiskA

Nuclear Energy is one of the most possible alternative to fossil energy in large-scale. Nuclear safety is the lifeline of nuclear energy development, and has been an important part of national security, especially after the accident of Fukushima. On the basis of computer codes, reliability engineering and Probabilistic Risk Assessment (PSA) is effective methods to improve the safety of nuclear power plants. After many years of development, the methodologies, applications and relevant soft programs have been quite sufficient in the area of nuclear safety. However, it is still difficult for the current PSA technologies and software to meet the needs of dealing with the problems of quantitatively public risk assessment in the digital society. Especially, there are so many software that adopted different modeling and analyzing methods, which brings difficulties to the comparison, evaluation or verification for different software and models. By using its own academic advantages, the advanced nuclear energy research team, i.e., FDS Team has invested a few hundreds person-years of independent research and development of a reliability and probabilistic safety assessment software system RiskA. The system consists of three main functions: device reliability optimization management, probabilistic safety assessment and instantaneous risk monitoring, and the comprehensive public risk assessment in digital society. RiskA establishes an integrated risk evaluation system for the device reliability, nuclear power plant (NPP) risk monitoring and public risk assessment. Currently, RiskA has successfully been applied in more than 600 organizations and institutes from a variety of fields in 39 countries, involving nuclear, aerospace, defense and so on. For example, RiskA has been used in the safety analysis of International Thermonuclear Experimental Reactor (ITER), FDS series fusion reactor, and the Strategic Priority Research Program of Chinese Academy of Sciences 'the Future Advanced Nuclear Fission Energy - Accelerator Driven Sub-critical (ADS) transmutation system'. Also, RiskA has been used in public risk communication and risk assessment. Among them, Third Qinshan nuclear power plant Risk Monitor (TQRM), which is the China's first domestic nuclear safety analysis software used in the actual online operation, has been highly apprised by renowned experts in the field. Meanwhile, it has been identified as the first domestic nuclear power plant risk monitoring system with completely independent intellectual property rights, and has reached the international advanced level. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rapid Data Assimilation in the Indoor Environment: theory and examples from real-time interpretation of indoor plumes of airborne chemicals

Releases of acutely toxic airborne contaminants in or near a building can lead to significant human exposures unless prompt response measures are identified and implemented. Commonly, possible responses include conflicting strategies, such as shutting the ventilation system off versus running it in a purge (100percent outside air) mode, or having occupants evacuate versus sheltering in place. The right choice depends in part on quickly identifying the source locations, the amounts released, and the likely future dispersion routes of the pollutants. This paper summarizes recent developments to provide such estimates in real time using an approach called Bayesian Monte Carlo updating. This approach rapidly interprets measurements of airborne pollutant concentrations from multiple sensors placed in the building and computes best estimates and uncertainties of the release conditions. The algorithm is fast, capable of continuously updating the estimates as measurements stream in from sensors. The approach is employed, as illustration, to conduct two specific investigations under different situations.

54 ENVIRONMENTAL SCIENCES↗

Monte Carlo simulation of a Bonner sphere spectrometer for application to the determination of neutron field in the Experimental Advanced Superconducting Tokamak experimental hall

To assess the neutron energy spectra and the neutron dose for different positions around the Experimental Advanced Superconducting Tokamak (EAST) device, a Bonner Sphere Spectrometer (BSS) was developed at Peking University, with totally nine polyethylene spheres and a SP9 {sup 3}He counter. The response functions of the BSS were calculated by the Monte Carlo codes MCNP and GEANT4 with dedicated models, and good agreement was found between these two codes. A feasibility study was carried out with a simulated neutron energy spectrum around EAST, and the simulated “experimental” result of each sphere was obtained by calculating the response with MCNP, which used the simulated neutron energy spectrum as the input spectrum. With the deconvolution of the “experimental” measurement, the neutron energy spectrum was retrieved and compared with the preset one. Good consistence was found which offers confidence for the application of the BSS system for dose and spectrum measurements around a fusion device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2D soft x-ray system on DIII-D for imaging the magnetic topology in the pedestal region

A new tangential two-dimensional soft x-ray imaging system (SXRIS) is being designed to examine the edge island structure in the lower X-point region of DIII-D. Plasma shielding and/or amplification of the calculated vacuum islands may play a role in the suppression of edge-localized modes via resonant magnetic perturbations (RMPs). The SXRIS is intended to improve the understanding of three-dimensional (3D) phenomena associated with RMPs. This system utilizes a tangential view with a pinhole imaging system and spectral filtering with beryllium foils. SXR emission is chosen to avoid line radiation and allows suitable signal at the top of a H-mode pedestal where T{sub e}{approx}1-2 keV. A synthetic diagnostic calculation based on 3D SXR emissivity estimates is used to help assess signal levels and resolution of the design. A signal-to-noise ratio of 10 at 1 cm resolution is expected for the perturbed signals, which are sufficient to resolve most of the predicted vacuum island sizes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of a high resolution grating soft x-ray spectrometer

The calibration of the soft x-ray spectral response of a large radius of curvature, high resolution grating spectrometer (HRGS) with a back-illuminated charge-coupled device detector is reported. The instrument is cross-calibrated for the 10-50 A waveband at the Lawrence Livermore National Laboratory electron beam ion trap (EBIT) x-ray source with the EBIT calorimeter spectrometer. The HRGS instrument is designed for laser-produced plasma experiments and is important for making high dynamic range measurements of line intensities, line shapes, and x-ray sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of X-ray imaging devices for accurate intensity measurement

National Security Technologies (NSTec) has developed calibration procedures for X-ray imaging systems using NIST traceable sources. The X-ray sources that are used for calibration are both diode type and diode/fluorescer combinations. Calibrating the X-ray detectors is the key to accurate calibration of the X-ray sources. Both energy dispersive detectors and photodiodes measuring total flux were used. We have developed calibration techniques for the detectors using radioactive sources that are traceable to the National Institute of Standards and Technology (NIST). The German synchrotron at Physikalische Technische Bundestalt (PTB) is used to calibrate silicon photodiodes over the energy range from 50 eV to 60 keV. The measurements on X-ray cameras made using the NSTec X-ray sources have included the quantum efficiency averaged over all pixels, the camera counts per photon per pixel, and response variation across the sensor. The instrumentation required to accomplish the calibrations is described. X-ray energies ranged from 720 eV to 22.7 keV. The X-ray sources produce narrow energy bands, allowing us to determine the properties as a function of X-ray energy. The calibrations were done for several types of imaging devices. There were back illuminated and front illuminated CCD (charge coupled device) sensors, and a CID (charge injection device) type camera. The CCD and CID camera types differ significantly in some of their properties that affect the accuracy of X-ray intensity measurements. All cameras discussed here are silicon based. The measurements of quantum efficiency variation with X-ray energy are compared to models for the sensor structure. Cameras that are not back-thinned are compared to those that are.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Light output enhanced fast response and low afterglow {sup 6}Li glass scintillator as potential down-scattered neutron diagnostics for inertial confinement fusion

The characteristics of an APLF80+3Ce scintillator are presented. Its sufficiently fast decay profile, low afterglow, and an improved light output compared to the recently developed APLF80+3Pr, were experimentally demonstrated. This scintillator material holds promise for applications in neutron imaging diagnostics at the energy regions of 0.27 MeV of DD fusion down-scattered neutron peak at the world's largest inertial confinement fusion facilities such as the National Ignition Facility and the Laser Megajoule.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visualization of the operational space of edge-localized modes through low-dimensional embedding of probability distributions

Information visualization aimed at facilitating human perception is an important tool for the interpretation of experiments on the basis of complex multidimensional data characterizing the operational space of fusion devices. This work describes a method for visualizing the operational space on a two-dimensional map and applies it to the discrimination of type I and type III edge-localized modes (ELMs) from a series of carbon-wall ELMy discharges at JET. The approach accounts for stochastic uncertainties that play an important role in fusion data sets, by modeling measurements with probability distributions in a metric space. The method is aimed at contributing to physical understanding of ELMs as well as their control. Furthermore, it is a general method that can be applied to the modeling of various other plasma phenomena as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An imaging proton spectrometer for short-pulse laser plasma experiments

The ultraintense short pulse laser pulses incident on solid targets can generate energetic protons. In addition to their potentially important applications such as in cancer treatments and proton fast ignition, these protons are essential to understand the complex physics of intense laser plasma interaction. To better characterize these laser-produced protons, we designed and constructed a novel spectrometer that will not only measure proton energy distribution with high resolution but also provide its angular characteristics. The information obtained from this spectrometer compliments those from commonly used diagnostics including radiochromic film packs, CR39 nuclear track detectors, and nonimaging magnetic spectrometers. The basic characterizations and sample data from this instrument are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charged fusion product loss measurements using nuclear activation

In ITER, {alpha} particle loss measurements will be required in order to understand the alpha particle physics. Techniques capable of operating in a fusion reactor environment need further development. Recent experimental studies on JET demonstrated the potential of nuclear activation to measure the flux of escaping MeV ions. New results from MeV ion induced activation of metallic, ceramic, and crystal samples placed near the plasma edge are reported. Activation products were measured as function of orientation with respect to the magnetic field as well as function of the distance to the plasma. Sample activity was measured using ultralow-level gamma-ray spectrometry. Distribution of 14.68 MeV fusion proton induced activation products is strongly anisotropic in agreement with simulations and falls off sharply with increasing distance to the plasma. Prospects for using the technique in ITER are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lineshape spectroscopy with a very high resolution, very high signal-to-noise crystal spectrometer

We have developed a high-resolution x-ray spectrometer for measuring the shapes of spectral lines produced from laser-irradiated targets on the Orion laser facility. The instrument utilizes a spherically bent crystal geometry to spatially focus and spectrally analyze photons from foil or microdot targets. The high photon collection efficiency resulting from its imaging properties allows the instrument to be mounted outside the Orion chamber, where it is far less sensitive to particles, hard x-rays, or electromagnetic pulses than instruments housed close to the target chamber center in ten-inch manipulators. Moreover, Bragg angles above 50° are possible, which provide greatly improved spectral resolution compared to radially viewing, near grazing-incidence crystal spectrometers. These properties make the new instrument an ideal lineshape diagnostic for determining plasma temperature and density. We describe its calibration on the Livermore electron beam ion trap facility and present spectral data of the K-shell emission from highly charged sulfur produced by long-pulse as well as short-pulse beams on the Orion laser in the United Kingdom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molecular Dynamics Investigation of Lipid-Specific Interactions with a Fusion Peptide

The HIV-1 fusion peptide, which is a short hydrophobic peptide from the gp41 coat glycoprotein that participates in the infection of a cell, interacts with model lipid bilayer membranes in a concentration-dependent manner. The interaction of the peptide with the bilayer also strongly depends on the lipid composition. Here, molecular dynamics simulations were performed to investigate lipid-specific interactions that arise shortly after the binding of a less-fusogenic variant of the HIV-1 fusion peptide to a lipid bilayer composed of a mixture of dimyristoyl phosphatidylcholine and dimyristoyl phosphatidylglycerol. The impact of peptide concentration was also studied. An improved understanding was gained of the lipid-specific interactions experienced by the FP. New insight was also gained into how the peptide concentration changes these interactions.

60 APPLIED LIFE SCIENCES↗