OPEN-CODE, REAL-TIME EMULATION TESTBED OF GRID-CONNECTED TYPE-3 WIND TURBINE SYSTEM WITH HARDWARE VALIDATION

This paper presents the design and development of an open-code Type-3 wind turbine virtual-testbed for real-time simulations. The proposed testbed includes the bare code for all the models required to emulate a Type-3 wind turbine system: the Doubly-Fed Induction Generator (DFIG) dynamic model, single-mass drive train, wind turbine system, and average model of the back to back power. This testbed can be executed in PC-layer for offline simulations or can be executed in real-time on the National Instruments (NI)-CompactRIO (cRIO) platform. The discrete-time models are implemented on the Field Programmable Gate Array (FPGA), using LabVIEW, and validated against a physical hardware setup. The emulated stator and rotor currents and DC-link voltage are compared against physical measurements creating a validated platform independent from third-party models and suitable for applications in real-time. The proposed testbed is intended to be available to researchers, wind turbine manufacturers, and utility companies to perform tests using a validated platform to verify proposed control designs of DFIG wind turbines.

Ferrari Maglia, Max↗

A Modular Integration Design of LCL Circuit Featuring Field Enhancement and Misalignment Tolerance for Wireless EV Charging

One of the major challenges of high-order wireless charging circuit is to reduce the system volume and cost induced by its additional components. Based on an LCL-S circuit, this paper proposes a modular integration design, in which an identical compensation inductor and transmitter are closely coupled. A new compensation method is derived to enable zero phase angle (ZPA) and constant current (CC) output. Identical currents are fed into the same reference terminals of both inductors to enable transmission field enhancement and to eliminate reactive power flow between the inductors. A misalignment tolerant coil is used to improve the output power stability under random parking imperfection. The proposed integration design achieves enhanced transmission capacity. Experiments are carried out to verify the proposed design.

Zhang, Pengcheng↗

Development of 50kV air-core transformer for electron gun static power source of 3MeV DC accelerator

A 3 MeV, 10 mA DC Electron Beam Accelerator based on the capacitively coupled parallel-fed voltage multiplier in 6 kg/cm{sup 2} SF{sub 6} gas environment is under commissioning at Electron Beam Centre, Kharghar, Navi Mumbai. Electron Gun is situated at -3 MV terminal which requires a constant power for its anode and filament. Gun power source has been derived by suitably coupling the ac components present in the HV Multiplier column. An aircore step down transformer rated for 50kV/600V/120kHz floating at 3 MV to extract the required power for electron gun from high voltage column has been developed. The transformer has been operated for 7 kW, 1 MeV of electron beam in 6 kg/cm{sup 2} nitrogen gas environment. The paper describes briefly about the design aspects and test results. (author)

43 PARTICLE ACCELERATORS↗

Variable-Speed Wind Power Plant Operating With Reserve Power Capability: Preprint

As the level of wind penetration increases, wind turbine technology must move from merely generating power from wind to taking a role in supporting the bulk power system. Wind turbines should have the capability to provide inertial response and primary frequency (governor) response. Wind turbine generators with this capability can support the frequency stability of the grid. To provide governorresponse, wind turbines should be able to generate less power than the available wind power and hold the rest in reserves, ready to be accessed as needed. In this paper, we explore several ways to control wind turbine output to enable reserve-holding capability. The focus of this paper is on doubly-fed induction generator (also known as Type 3) and full-converter (also known as Type 4) windturbines.

17 WIND ENERGY↗

On Stability of PQ-Controlled Grid-Following and Droop-Control Grid-Forming Inverters

In this paper, the nonlinearity impacts of PQ-control schemes and LCL filter parameter variations on the stability of grid-interactive inverters are studied under weak grid conditions. This work demonstrates that the control nonlinearity and parameter variations can cause unexpected instability at low power levels. This instability issue in the nominal operating range may occur under specific control parameters due to the shift of the low-frequency eigenvalues of PQ-controlled inverters. A full-order small-signal model for PQ-controlled inverters is applied to analyze this instability issue. Furthermore, the impacts of the droop coefficients on the stability of the droop-controlled grid-forming inverter are also investigated using the closed-loop inverter model. The findings are experimentally verified using a small-scale two-level 208 V, 5 kVA inverter feeding a 12 kW NHR 9410 power grid emulator and a hardware setup of a microgrid fed by two 5 kVA 208V inverters.

Hossen, Tareq↗

Grey-Box System Identification of Grid-Forming Inverters

This paper demonstrates the use of grey-box system identification methods for simplifying and understanding the nonlinear power dynamics of grid-forming inverters (GFMs). The power and frequency outputs of complex high-order GFM models are fed into system identification software in order to fit them to a predetermined LTI system and learn system parameters such as (synthetic) inertia and droop constants. The same process is then run for a high-order synchronous generator model, and the outputs are fit to the same set of LTI equations. Simulation of a network of GFM inverters with diverse control architecture is also performed for the same process. The intent is threefold: first, to demonstrate the appropriateness of unified LTI models for describing the power and frequency dynamics of individual resources and connected networks, in order to facilitate analysis of larger heterogeneous networked systems; second, to discover the relationship between internal control parameters of GFMs and their externally observed values; and third, to validate that grey-box data-driven system identification techniques can be a valuable tool to discover the values of important parameters in the absence of explicit vendor models.

analytical models↗

Inter-Area Oscillation Damping with Type-5 Wind Power Plant

This paper investigates the potential of using brushless excitation (BLE) for not only riding through the fault but also to damp inter-area power oscillation with the help of a synchronous generator (SG) used in Type 5 Wind Power Plant (WPP). In BLE, an auxiliary synchronous generator (ASG) behaving like an exciter is coupled and driven by the rotor of the main SG. The BLE's field current's ASG is fed by two separate loops of the automatic voltage regulator (AVR) and power system stabilizer (PSS). The AVR system implements a control loop to regulate the generator terminal voltage, VT. For the PSS, the kinetic energy of the wind turbine is utilized according to the estimated rotational speed of the synchronous generator shaft of the SG. It may mitigate the necessity of any curtailment of active power for damping. The effectiveness of the proposed control scheme is verified with a three-phase short circuit fault in a two-area power system.

brushless↗

Optimum Planning for Inductively Charged On-Demand Automated Electric Shuttles at Greenville, South Carolina

Wireless charging technology presents perfect fits for autonomous electric vehicles for realizing a fully automated system (vehicle and charger). This paper presents a planning optimization analysis for a pilot project of in-route wireless charging infrastructure serving fixed-route on-demand shared automated electric shuttles (SAESs) at Greenville, South Carolina, USA. A single-objective non-linear integer planning optimization problem is formulated. A comprehensive cost function representing the inductively charged SAESs is developed, considering road construction, power electronics and materials, traction battery, and installation costs. The optimization problem is solved to determine the best combination of the system key design parameters (number and allocations of wireless chargers, charging power level, track length and on-board battery capacity) that show the most cost-effective solution and allow the SAESs realizing charge sustaining operation. The planning platform incorporates representative simulated traffic data (drive cycles and routes) for four SAESs at Greenville project using the Simulation of Urban Mobility (SUMO) tool. These data are fed to a vehicle powertrain model and a wireless charger power model to predict the battery power, energy and state-of-charge (SOC) profiles, which are provided to the search algorithm to assess the design objectives under specific constraints. The results indicated that implementing wireless charging at a few designated stops for fixed-route SAESs with proper design allows the vehicles realizing charge sustaining operation, infinite range and zero recharge downtime, with a significant reduction in the on-board battery (36 % ) and road coverage (69%), at minimum cost.

33 ADVANCED PROPULSION SYSTEMS↗

Dynamic Load Inrush Current Mitigation in Islanded Microgrids Powered by Grid-Forming Inverters

Grid-forming inverters in a microgrid may trip due to high inrush current caused by a switched connection of an inductive load, e.g., a relatively large induction motor. The control scheme presented in this article includes virtual inertia control method superimposed on the cascaded controller. This article studies the impact of cascaded control scheme used for grid-forming inverter to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. Experimental tests are performed using the virtual inertia method for generating the reference angle for synchronous frame conversion. The experimental performance and sensitivity of the controller to different controller gain settings for a switched connection of an induction motor are discussed. The cascaded operation significantly mitigates the inrush currents while the inverters can perform a normal operation. The performance of the control method is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented.

Gursoy, Mehmetcan↗

Hierarchical Control Scheme for Improving Transient Voltage Recovery of a DFIG-Based WPP

Modern grid codes require that wind power plants (WPPs) inject reactive power according to the voltage dip at a point of interconnection (POI). This requirement helps to support a POI voltage during a fault. However, if a fault is cleared, the POI and wind turbine generator (WTG) voltages are likely to exceed acceptable levels unless the WPP reduces the injected reactive power quickly. This might deteriorate the stability of a grid by allowing the disconnection of WTGs to avoid any damage. This paper proposes a hierarchical control scheme of a doubly-fed induction generator (DFIG)-based WPP. The proposed scheme aims to improve the reactive power injecting capability during the fault and suppress the overvoltage after the fault clearance. To achieve the former, an adaptive reactive power-to-voltage scheme is implemented in each DFIG controller so that a DFIG with a larger reactive power capability will inject more reactive power. To achieve the latter, a washout filter is used to capture a high frequency component contained in the WPP voltage, which is used to remove the accumulated values in the proportional-integral controllers. Test results indicate that the scheme successfully supports the grid voltage during the fault, and recovers WPP voltages without exceeding the limit after the fault clearance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model-Free Dynamic Voltage Control of a Synchronous Generator-Based Microgrid

The main goal of this paper is to present a new dynamic voltage stability mechanism, based on model-free control (MFC), for effective control and coordination of synchronous generator (SG)-based reactive power resources in a microgrid setting. MFC has shown successful operation in various domains, and this paper presents its first use in the voltage stability of a power system. It is utilized as an online controller to achieve the dynamic voltage stability of a microgrid system under different disturbances and fault conditions. A 21-bus microgrid system fed by SG-based distributed energy resources (DERs) is considered as a use case study. The overall dynamic voltage stability of the microgrid system is investigated using time-domain dynamic simulations during emergency, hazard, and disaster events. Simulation results show that there are significant improvements and enhancements on the dynamic load bus voltage profiles of the microgrid system by the effective model-free control and coordination of the reactive power reserves of the SG-based DERs.

Hatipoglu, Kenan↗

A Novel Three-Phase Isolated LLC and Non-Isolated LCL-T Resonant Converter for Fuel Cell Applications

In this paper, a novel three-phase isolated LLC and non-isolated LCL−T resonant converter topologies are introduced for fuel cell applications. In order to improve the fuel cell DC/DC converter efficiency, the current amplitude should be reduced in the power stage components. Cascaded connections of fuel cell blocks through a controllable system enable using higher voltage amplitude and bring the current amplitude lower at the target power. In this way, power losses in the passive components can be reduced, and maximum energy transfer can be established, improving the DC/DC converter efficiency from the fuel cell to the load. The introduced new converter also achieves soft switching (ZVS), minimizing the switching losses in all input and output load conditions. The presented three-phase isolated LLC and non-isolated LCL−T resonant converter systems, fed by three fuel cell modules with an output range of 190380 V, deliver 580−730 V at 450 kW maximum output power. The results reveal that the proposed systems have the advantage of reducing the size, volume, and weight and increasing the overall DC/DC converter system efficiency compared to the single-phase systems.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

FPGA-Based Optical Cavity Phase Stabilization for Coherent Pulse Stacking

Coherent pulse stacking (CPS) is a new time-domain coherent addition technique that stacks several optical pulses into a single output pulse, enabling high pulse energy from fiber lasers. We develop a robust, scalable, and distributed digital control system with firmware and software integration for algorithms, to support the CPS application. We model CPS as a digital filter in the Z domain and implement a pulse-pattern-based cavity phase detection algorithm on an field-programmable gate array (FPGA). A two-stage (2+1 cavities) 15-pulse stacking system achieves an 11.0 peak-power enhancement factor. Each optical cavity is fed back at 1.5kHz, and stabilized at an individually-prescribed round-trip phase with 0.7deg and 2.1deg rms phase errors for Stages 1 and 2, respectively. Optical cavity phase control with nanometer accuracy ensures 1.2% intensity stability of the stacked pulse over 12 h. The FPGA-based feedback control system can be scaled to large numbers of optical cavities.

43 PARTICLE ACCELERATORS↗

Noise Radar Approach for Interrogating SAW Sensors Using Software Defined Radio

Passive, wireless surface acoustic wave (SAW) sensor systems can be approached from a radar perspective, where the SAW device is thought of as a cooperative target. Here, this paper investigates the use of a commercial-off-the-shelf software defined radio to interrogate wireless SAW sensors with a randomly generated interrogation pulse. The USRP B200mini is utilized as the transceiver platform with custom field-programmable gate array (FPGA) modifications to generate the random interrogation waveform and provide synchronization and buffering to the received signal. Each transmit sample bit in the FPGA is fed by an independent linear-feedback shift register, which generates pseudo-random I and Q samples for the interrogation pulse. An RF daughterboard has also been developed and integrated with the B200mini to increase the transmit power, provide filtering of the RF signals, and switch a signal antenna between the transmit and receive channels. Radio control and matched filter correlator post-processing are accomplished using Python. Design and implementation details for the FPGA modifications, RF daughterboard, and post-processing are discussed. Lastly, the system is demonstrated by wirelessly interrogating SAW temperature sensors at 915 MHz.

47 OTHER INSTRUMENTATION↗

Heuristic Dynamic Programming for Adaptive Virtual Synchronous Generators

In this paper a neural network heuristic dynamic programing (HDP) is used for optimal control of the virtual inertia-based control of grid connected three-phase inverters. It is shown that the conventional virtual inertia controllers are not suited for non-inductive grids. A neural network-based controller is proposed to adapt to any impedance angle. Applying an adaptive dynamic programming controller instead of a supervised controlled method enables the system to adjust itself to different conditions. The proposed HDP consists of two subnetworks: critic network and action network. These networks can be trained during the same training cycle to decrease the training time. The simulation results confirm that the proposed neural network HDP controller performs better than the traditional direct-fed voltage and/or reactive power controllers in virtual inertia control schemes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantum Computation and Visualization of Hamiltonians Using Discrete Quantum Mechanics and IBM QISKit

Quantum computers have the potential to transform the ways in which we tackle some important problems. The efforts by companies like Google, IBM and Microsoft to construct quantum computers have been making headlines for years. Equally important is the challenge of translating problems into a state that can be fed to these machines. Because quantum computers are in essence controllable quantum systems, the problems that most naturally map to them are those of quantum mechanics. Quantum chemistry has seen particular success in the form of the variational quantum eigensolver (VQE) algorithm, which is used to determine the ground state energy of molecular systems. The goal of our work has been to use the matrix formulation of quantum mechanics to translate other systems so that they can be run through this same algorithm. We describe two ways of accomplishing this using a position basis approach and a Gaussian basis approach. We use this translation to compute finite temperature quantities such as the average energy as a function of temperature. We do this by constructing a 0+1- dimensional thermal field theory, constructing a thermal double of the system and using tensor products to construct operators in the system coupled to a heat bath. We also discuss how to include a chemical potential in the quantum computations. We then connect the 0+1 formalism to gauge theory by using an effective matrix model description used in nuclear theory. We study effective potentials for components of the gauge field and use the VQE algorithm to calculate the ground state energies. We also visualize the wave functions from the eigensolver and make comparisons to theoretical results obtained with continuous operators.

97 MATHEMATICS AND COMPUTING↗

Synthesizing Distributed Energy Resources in Microgrids with Temporal Logic Specifications

Grid supportive modes integrated within distributed energy resources aim at improving the frequency response. However, hybrid behaviors induced by deadbands and other thresholds and their impact on system frequency remain unclear. This paper employs the parametric metric temporal logic specification for validating such behaviors to ensure adequate frequency response. It allows a richer description of system protections like under-frequency load shedding and can explore the temporal specification of frequency dynamics. The approach is applied on a diesel-wind fed microgrid and appropriate settings of deadband will be obtained, which can be regarded as a guideline for practitioners. The results are expected to be less conservative since the temporal properties are taken into accounts.

Zhang, Yichen↗

Dynamic State Estimation and Parameter Calibration of DFIG based on Ensemble Kalman Filter

With the growing interest in the application of wind energy, doubly fed induction generator (DFIG) plays an essential role in the industry nowadays. To deal with the increasing stochastic variations introduced by intermittent wind resource and responsive loads, dynamic state estimation (DSE) are introduced in any power system associated with DFIGs. However, sometimes this dynamic analysis canould not work because the parameters of DFIGs are not accurate enough. To solve the problem, an ensemble Kalman filter (EnKF) method is proposed for the state estimation and parameter calibration tasks. In this paper, a DFIG is modeled and implemented with the EnKF method. Sensitivity analysis is demonstrated regarding the measurement noise, initial state errors and parameter errors. The results indicate this EnKF method has a robust performance on the state estimation and parameter calibration of DFIGs.

Fan, Rui↗