Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Error analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Super-resolution reconstruction for 4D computed tomography of the lung via the projections onto convex sets approach

Purpose: The use of 4D computed tomography (4D-CT) of the lung is important in lung cancer radiotherapy for tumor localization and treatment planning. Sometimes, dense sampling is not acquired along the superior–inferior direction. This disadvantage results in an interslice thickness that is much greater than in-plane voxel resolutions. Isotropic resolution is necessary for multiplanar display, but the commonly used interpolation operation blurs images. This paper presents a super-resolution (SR) reconstruction method to enhance 4D-CT resolution. Methods: The authors assume that the low-resolution images of different phases at the same position can be regarded as input “frames” to reconstruct high-resolution images. The SR technique is used to recover high-resolution images. Specifically, the Demons deformable registration algorithm is used to estimate the motion field between different “frames.” Then, the projection onto convex sets approach is implemented to reconstruct high-resolution lung images. Results: The performance of the SR algorithm is evaluated using both simulated and real datasets. Their method can generate clearer lung images and enhance image structure compared with cubic spline interpolation and back projection (BP) method. Quantitative analysis shows that the proposed algorithm decreases the root mean square error by 40.8% relative to cubic spline interpolation and 10.2% versus BP. Conclusions: A new algorithm has been developed to improve the resolution of 4D-CT. The algorithm outperforms the cubic spline interpolation and BP approaches by producing images with markedly improved structural clarity and greatly reduced artifacts.

60 APPLIED LIFE SCIENCES↗

Energy dependent calibration of XR-QA2 radiochromic film with monochromatic and polychromatic x-ray beams

Purpose: This work investigates the energy response and dose-response curve determinations for XR-QA2 radiochromic film dosimetry system used for synchrotron radiation work and for quality assurance in diagnostic radiology, in the range of effective energies 18–46.5 keV. Methods: Pieces of XR-QA2 films were irradiated, in a plane transverse to the beam axis, with a monochromatic beam of energy in the range 18–40 keV at the ELETTRA synchrotron radiation facility (Trieste, Italy) and with a polychromatic beam from a laboratory x-ray tube operated at 80, 100, and 120 kV. The film calibration curve was expressed as air kerma (measured free-in-air with an ionization chamber) versus the net optical reflectance change (netΔR) derived from the red channel of the RGB scanned film image. Four functional relationships (rational, linear exponential, power, and logarithm) were tested to evaluate the best curve for fitting the calibration data. The adequacy of the various fitting functions was tested by using the uncertainty analysis and by assessing the average of the absolute air kerma error calculated as the difference between calculated and delivered air kerma. The sensitivity of the film was evaluated as the ratio of the change in net reflectance to the corresponding air kerma. Results: The sensitivity of XR-QA2 films increased in the energy range 18–39 keV, with a maximum variation of about 170%, and decreased in the energy range 38–46.5 keV. The present results confirmed and extended previous findings by this and other groups, as regards the dose response of the radiochromic film XR-QA2 to monochromatic and polychromatic x-ray beams, respectively. Conclusions: The XR-QA2 radiochromic film response showed a strong dependence on beam energy for both monochromatic and polychromatic beams in the range of half value layer values from 0.55 to 6.1 mm Al and corresponding effective energies from 18 to 46.5 keV. In this range, the film response varied by 170%, from a minimum sensitivity of 0.0127 to a maximum sensitivity of 0.0219 at 10 mGy air kerma in air. The more suitable function for air kerma calibration of the XR-QA2 radiochromic film was the power function. A significant batch-to-batch variation, up to 55%, in film response at 120 kV (46.5 keV effective energy) was observed in comparison with published data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Linear diffraction grating interferometer with high alignment tolerance and high accuracy

We present an innovative structure of a linear diffraction grating interferometer as a long stroke and nanometer resolution displacement sensor for any linear stage. The principle of this diffractive interferometer is based on the phase information encoded by the {+-}1st order beams diffracted by a holographic grating. Properly interfering these two beams leads to modulation similar to a Doppler frequency shift that can be translated to displacement measurements via phase decoding. A self-compensation structure is developed to improve the alignment tolerance. LightTool analysis shows that this new structure is completely immune to alignment errors of offset, standoff, yaw, and roll. The tolerance of the pitch is also acceptable for most installation conditions. In order to compact the structure and improve the signal quality, a new optical bonding technology by mechanical fixture is presented so that the miniature optics can be permanently bonded together without an air gap in between. For the output waveform signals, a software module is developed for fast real-time pulse counting and phase subdivision. A laser interferometer HP5529A is employed to test the repeatability of the whole system. Experimental data show that within 15 mm travel length, the repeatability is within 15 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An atmospheric muon neutrino disappearance measurement with the MINOS far detector

It is now widely accepted that the Standard Model assumption of massless neutrinos is wrong, due primarily to the observation of solar and atmospheric neutrino flavor oscillations by a small number of convincing experiments. The MINOS Far Detector, capable of observing both the outgoing lepton and associated showering products of a neutrino interaction, provides an excellent opportunity to independently search for an oscillation signature in atmospheric neutrinos. To this end, a MINOS data set from an 883 live day, 13.1 kt-yr exposure collected between July, 2003 and April, 2007 has been analyzed. 105 candidate charged current muon neutrino interactions were observed, with 120.5 ± 1.3 (statistical error only) expected in the absence of oscillation. A maximum likelihood analysis of the observed log(L/E) spectrum shows that the null oscillation hypothesis is excluded at over 96% confidence and that the best fit oscillation parameters are sin 2 2θ 23 = 0.95 -0.32 and Δm$2\atop{23}$ = 0.93$+3.94\atop{ -0.44}$ x 10 -3 eV 2 . This measurement of oscillation parameters is consistent with the best fit values from the Super-Kamiokande experiment at 68% confidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A statistical analysis of the beam position measurement in the Los Alamos proton storage ring

The beam position monitors (BPMs) are the main diagnostic in the Los Alamos Proton Storage Ring (PSR). They are used in several applications during operations and tuning including orbit bumps and measurements of the tune, closed orbit (CO), and injection offset. However the BPM data acquisition system makes use of older technologies, such as matrix switches, that could lead to faulty measurements. This is the first statistical study of the PSR BPM perfonnance using BPM measurements. In this study, 101 consecutive CO measurements are analyzed. Reported here are the results of the statistical analysis, tune and CO measurement spreads, the BPM single turn measurement error, and examples of the observed data acquisition errors.

43 PARTICLE ACCELERATORS↗

Ellipsometry

Ellipsometry is a technique often used to measure the thickness and properties of a thin film. This article covers the instrumental, theoretical, and practical aspects of this technique. Notably, different types of instruments including nulling ellipsometer, rotating compensator ellipsometer, and photoelastic modulator ellipsometer designs are presented. Elements of proper data analysis are also included, such as the use of an error-based figure of merit.

Complex reflection coefficients↗

Centroid Position as a Function of Total Counts in a Windowed CMOS Image of a Point Source

We obtained 960,200 22-by-22-pixel windowed images of a pinhole spot using the Teledyne H2RG CMOS detector with un-cooled SIDECAR readout. We performed an analysis to determine the precision we might expect in the position error signals to a telescope's guider system. We find that, under non-optimized operating conditions, the error in the computed centroid is strongly dependent on the total counts in the point image only below a certain threshold, approximately 50,000 photo-electrons. The LSST guider camera specification currently requires a 0.04 arcsecond error at 10 Hertz. Given the performance measured here, this specification can be delivered with a single star at 14th to 18th magnitude, depending on the passband.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Partial Least Squares, Experimental Design, and Near-Infrared Spectrophotometry for the Remote Quantification of Nitric Acid Concentration and Temperature

Near-infrared spectrophotometry and partial least squares regression (PLSR) were evaluated to create a pleasantly simple yet effective approach for measuring HNO3 concentration with varying temperature levels. A training set, which covered HNO3 concentrations (0.1–8 M) and temperature (10–40 °C), was selected using a D-optimal design to minimize the number of samples required in the calibration set for PLSR analysis. The top D-optimal-selected PLSR models had root mean squared error of prediction values of 1.4% for HNO 3 and 4.0% for temperature. The PLSR models built from spectra collected on static samples were validated against flow tests including HNO 3 concentration and temperature gradients to test abnormal conditions (e.g., bubbles) and the model performance between sample points in the factor space. Based on cross-validation and prediction modeling statistics, the designed near-infrared absorption approach can provide remote, quantitative analysis of HNO 3 concentration and temperature for production-oriented applications in facilities where laser safety challenges would inhibit the implementation of other optical techniques (e.g., Raman spectroscopy) and in which space, time, and/or resources are constrained. The experimental design approach effectively minimized the number of samples in the training set and maintained or improved PLSR model performance, which makes the described chemometric approach more amenable to nuclear field applications.

07 ISOTOPE AND RADIATION SOURCES↗

Impact of point spread function higher moments error on weak gravitational lensing

ABSTRACT Weak gravitational lensing is one of the most powerful tools for cosmology, while subject to challenges in quantifying subtle systematic biases. The point spread function (PSF) can cause biases in weak lensing shear inference when the PSF model does not match the true PSF that is convolved with the galaxy light profile. Although the effect of PSF size and shape errors – i.e. errors in second moments – is well studied, weak lensing systematics associated with errors in higher moments of the PSF model require further investigation. The goal of our study is to estimate their potential impact for LSST weak lensing analysis. We go beyond second moments of the PSF by using image simulations to relate multiplicative bias in shear to errors in the higher moments of the PSF model. We find that the current level of errors in higher moments of the PSF model in data from the Hyper Suprime-Cam survey can induce a ∼0.05 per cent shear bias, making this effect unimportant for ongoing surveys but relevant at the precision of upcoming surveys such as LSST.

79 ASTRONOMY AND ASTROPHYSICS↗

Covariances from Light-Element R-Matrix Analyses

We review the method for obtaining covariance information for light-element reactions using R-matrix theory. The general LANL R-matrix analysis code EDA provides accurate covariances for the resonance parameters at a solution due to the search algorithm it uses to find a local minimum of the chi-square surface. This information is used, together with analytically calculated sensitivity derivatives, in the first-order error propagation equation to obtain cross-section covariances for all reactions included in the analysis. Examples are given of the covariances obtained from the EDA analyses for n-p scattering and for the n+{sup 6}Li reactions used in the latest light-element standard cross section evaluation. Also discussed is a method of defining 'pure theory' correlations that could be useful for extensions to higher energies and heavier systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Covariances from light-element r-martix analyses

We review the method for obtaining covariance information for light-element reactions using R-matrix theory. The general LANL R-matrix analysis code EDA provides accurate covariances for the resonance parameters at a solution due to the search algorithm it uses to find a local minimum of the chi-square surface. This information is used, together with analytically calculated sensitivity derivatives, in the first-order error propagation equation to obtain cross-section covariances for all reactions included in the analysis. Examples are given of the covariances obtained from the EDA analyses for n-p scattering and for the n+{sup 6}Li reactions used in the latest light-element standard cross section evaluation. Also discussed is a method of defining 'pure theory' correlations that could be useful for extensions to higher energies and heavier systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Computational Errors in the Calculation of Long Radioactive Decay Chains

For safety security of objects utilizing atomic energy, the effect of numerical errors on the calculation of the activity and integrals of the activity in time when using Bateman’s formula and Siewers’ algorithm to calculate radioactive decay chains is investigated. The smallest errors obtain when using Siewers’ algorithm and Bateman’s formula together with long arithmetic. It is shown that the standard calculations of radioactive decay chains according to Bateman’s formula with double precision lead to significant errors. However, these errors have almost no effect on the dose characteristics of mixtures of radionuclides. The analysis is based on data contained in ICRP Publication No. 107.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Probing modifications of general relativity using current cosmological observations

We test general relativity (GR) using current cosmological data: the CMB from WMAP5 [E. Komatsu et al. (WMAP Collaboration), Astrophys. J. Suppl. Ser. 180, 330 (2009)], the integrated Sachs-Wolfe (ISW) effect from the cross correlation of the CMB with six galaxy catalogs [T. Giannantonio et al., Phys. Rev. D 77, 123520 (2008)], a compilation of supernovae (SNe) type Ia including the latest Sloan Digital Sky Survey SNe [R. Kessler et al., Astrophys. J. Suppl. Ser. 185, 32 (2009).], and part of the weak lensing (WL) data from the Canada-Franco-Hawaii Telescope Legacy Survey [L. Fu et al., Astron. Astrophys. 479, 9 (2008); M. Kilbinger et al., Astron. Astrophys. 497, 677 (2009).] that probe linear and mildly nonlinear scales. We first test a model in which the effective Newtonian constant {mu} and the ratio of the two gravitational potentials, {eta}, transit from the GR value to another constant at late times; in this case, we find that GR is fully consistent with the combined data. The strongest constraint comes from the ISW effect which would arise from this gravitational transition; the observed ISW signal imposes a tight constraint on a combination of {mu} and {eta} that characterizes the lensing potential. Next, we consider four pixels in time and space for each function {mu} and {eta}, and perform a principal component analysis, finding that seven of the resulting eight eigenmodes are consistent with GR within the errors. Only one eigenmode shows a 2{sigma} deviation from the GR prediction, which is likely to be due to a systematic effect. However, the detection of such a deviation demonstrates the power of our time- and scale-dependent principal component analysis methodology when combining observations of structure formation and expansion history to test GR.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigating the mechanisms responsible for the lack of surface energy balance closure in a central Amazonian tropical rainforest

This work investigates the diurnal and seasonal behavior of the energy balance residual (E) that results from the observed difference between available energy and the turbulent fluxes of sensible heat (H) and latent heat (LE) at the FLUXNET BR-Ma2 site located in the Brazilian central Amazon rainforest. The behavior of E is analyzed by extending the eddy covariance averaging length from 30 min to 4 h and by applying an Information Flow Dynamical Process Network to diagnose processes and conditions affecting E across different seasons. Results show that the seasonal turbulent flux dynamics and the Bowen ratio are primarily driven by net radiation (R n ), with substantial sub-seasonal variability. The Bowen ratio increased from 0.25 in April to 0.4 at the end of September. Extension of the averaging length from 0.5 (94.6% closure) to 4 h and thus inclusion of longer timescale eddies and mesoscale processes closes the energy balance and lead to an increase in the Bowen ratio, thus highlighting the importance of additional H to E. Information flow analysis reveals that the components of the energy balance explain between 25 and 40% of the total Shannon entropy with higher values during the wet season than the dry season. Dry season information flow from the buoyancy flux to E are 30–50% larger than that from H, indicating the potential importance of buoyancy fluxes to closing E. While the low closure highlights additional sources not captured in the flux data and random measurement errors contributing to E, the findings of the information flow and averaging length analysis are consistent with the impact of mesoscale circulations, which tend to transport more H than LE, on the lack of closure.

54 ENVIRONMENTAL SCIENCES↗

XRD micro-XANES EMPA and SIMS investigation on phlogopite single crystals from Mt. Vulture (Italy)

Selected phlogopite flakes from Mt. Vulture in southern Italy were studied using a combination of single-crystal techniques: electron microprobe analysis (EMPA), secondary ion mass spectrometry (SIMS), single-crystal X-ray diffraction (SCXRD), and micro-X-ray absorption near-edge spectroscopy (XANES). The latter technique was employed to analyze the structure of the Fe-K absorption edge over the region from 7080-8100 eV and to determine Fe{sup 3+}/{Sigma}Fe at a micrometer scale, albeit with large error bars due to known effects of orientation on pre-edge energy. The annite component, Fe/(Mg+Fe), of the samples studied ranged from 0.16 to 0.31, the Ti content from 0.11 to 0.27 atoms per formula unit (apfu) and the Ba content from 0.03 to 0.09 apfu. SIMS analysis showed H{sub 2}O (wt%) = 1.81-3.30, F (wt%) = 0.44-1.29, and Li{sub 2}O (wt%) = 0.001-0.027. The intra single-crystal chemical variability for major/minor elements (Mg, Fe, Al, Ba, Ti, and K) was found particularly significant for samples VUT191{_}11 and PG5{_}1, less significant for the other samples of the set. SIMS data relative to crystals VUT187{_}24, VUT191{_}10, VUT191{_}11, and VUT187{_}28 showed a noteworthy variation in the concentrations of some light elements (H, Li, and F) with coefficient of variation CV (as 1{sigma}%) up to {approx}18% for H{sub 2}O. The analyzed micas belong to the 1M polytype. Structure refinements using anisotropic displacement parameters were performed in space group C2/m and converged at 3.08 {<=} R {<=} 3.63, 3.32 {<=} R{sub w} {<=} 3.98%. Micro-XANES results yielded Fe{sup 3+}/{Sigma}Fe from 51-93%. Previous Moessbauer data from powdered samples suggested Fe{sup 3+}/{Sigma}Fe values ranging from 49-87%. However, the Fe{sup 3+} content determined by both techniques is sometimes remarkably different, in part because of the large errors ({+-}10-15%) presently associated with the micro-XANES technique and in part because the Fe{sup 3+} content of a single crystal may significantly depart from the average value obtained from routine Moessbauer analysis. The combination of EMPA, SIMS, and micro-XANES resulted in the characterization of the samples at a comparable spatial scale. By means of in-situ data and the results of crystallographic investigations, the occurrence of different relative amounts of M{sup 3+}-oxy [{sup VI}M{sup 2+} + (OH){sup -} {leftrightarrow} {sup VI}M{sup 3+} + O{sup 2-} + {1/2}H{sub 2}{up_arrow}], Ti-oxy substitutions [{sup VI}M{sup 2+} + 2(OH){sup -} {leftrightarrow} {sup VI}Ti{sup 4+} + 2O{sup 2-} + H{sub 2}{up_arrow}], and Ti-vacancy ({open_square}) substitution (2{sup VI}M{sup 2+} {leftrightarrow} {sup VI}Ti{sup 4+} + {sup VI}{open_square}) was ascertained for the studied samples.

58 GEOSCIENCES↗

FY-16 Technology Gap Study Technical Report: Analysis of Undissolved Anode Materials of Mark-IV Electrorefiner

The Experimental Breeder Reactor II (EBR-II) is a sodium cooled fast reactor developed at Argonne National Laboratory (ANL). The used fuels from the EBR-II are currently being treated in the Fuel Conditioning Facility (FCF) at the Idaho National Laboratory (INL). The Mark IV (Mk-IV) electrorefiner (ER) is a unit process in the FCF, which is primarily assigned to treating the used driver fuels. The stainless steel anode baskets hold the chopped spent driver fuel segments. During electrorefining, the anode baskets are immersed into the electrolyte and the used fuel is dissolved electrochemically. Perforated sides and bottoms allow the flow of the electrolyte into and out of the anode baskets. The steel cathode is also immersed into the electrolyte and collects the reduced products. The active metal contents in the used fuel (e.g., Cs, Sr, lanthanides, Pu, etc.) reacts with uranium cations in the electrolyte and progressively reports to the electrolyte. Noble metals are mostly retained in the cladding hulls. Varying quantities of zirconium are retained in the cladding hulls depending on the operational conditions of the Mk-IV ER. The undissolved anode materials are removed from the anode baskets and stored for subsequent metal waste form processing. These undissolved materials typically include undissolved fuels, stainless steel cladding, and adhering electrolyte. A couple of hulls are retrieved for chemical analysis and used for estimating the composition of the entire undissolved anode materials. The mass balance attempt based on this practice of estimating the undissolved anode materials has been a challenge due to inherently high sampling errors associated with heterogeneous undissolved material compositions. Responding to the prescribed challenge, this report investigates chemical analysis data as a whole and finds noticeable trends in the compositions of undissolved anode material samples with respect to the mass of the whole undissolved anode materials. Based upon this discovery, an empirical model is proposed.

36 MATERIALS SCIENCE↗

How to Build a Quantum Supercomputer: Scaling from Hundreds to Millions of Qubits

In the span of four decades, quantum computation has evolved from an intellectual curiosity to a potentially realizable technology. Today, small-scale demonstrations have become possible for quantum algorithmic primitives on hundreds of physical qubits and proof-of-principle error-correction on a single logical qubit. Nevertheless, despite significant progress and excitement, the path toward a full-stack scalable technology is largely unknown. There are significant outstanding quantum hardware, fabrication, software architecture, and algorithmic challenges that are either unresolved or overlooked. These issues could seriously undermine the arrival of utility-scale quantum computers for the foreseeable future. Here, we provide a comprehensive review of these scaling challenges. We show how the road to scaling could be paved by adopting existing semiconductor technology to build much higher-quality qubits, employing system engineering approaches, and performing distributed quantum computation within heterogeneous high-performance computing infrastructures. These opportunities for research and development could unlock certain promising applications, in particular, efficient quantum simulation/learning of quantum data generated by natural or engineered quantum systems. To estimate the true cost of such promises, we provide a detailed resource and sensitivity analysis for classically hard quantum chemistry calculations on surface-code error-corrected quantum computers given current, target, and desired hardware specifications based on superconducting qubits, accounting for a realistic distribution of errors. Furthermore, we argue that, to tackle industry-scale classical optimization and machine learning problems in a cost-effective manner, heterogeneous quantum-probabilistic computing with custom-designed accelerators should be considered as a complementary path toward scalability.

Mohseni, Masoud↗

Landslide monitoring using seismic refraction tomography – The importance of incorporating topographic variations

Seismic refraction tomography provides images of the elastic properties of subsurface materials in landslide settings. Seismic velocities are sensitive to changes in moisture content, which is a triggering factor in the initiation of many landslides. However, the application of the method to long-term monitoring of landslides is rarely used, given the challenges in undertaking repeat surveys and in handling and minimizing the errors arising from processing time-lapse surveys. This work presents a simple method and workflow for producing a reliable time-series of inverted seismic velocity models. This method is tested using data acquired during a recent, novel, long-term seismic refraction monitoring campaign at an active landslide in the UK. Potential sources of error include those arising from inaccurate and inconsistent determination of first-arrival times, inaccurate receiver positioning, and selection of inappropriate inversion starting models. At our site, a comparative analysis of variations in seismic velocity to real-world variations in topography over time shows that topographic error alone can account for changes in seismic velocity of greater than ±10% in a significant proportion (23%) of the data acquired. The seismic velocity variations arising from real material property changes at the near-surface of the landslide, linked to other sources of environmental data, are demonstrated to be of a similar magnitude. Over the monitoring period we observe subtle variations in the bulk seismic velocity of the sliding layer that are demonstrably related to variations in moisture content. This highlights the need to incorporate accurate topographic information for each time-step in the monitoring time-series. The goal of the proposed workflow is to minimize the sources of potential errors, and to preserve the changes observed by real variations in the subsurface. Following the workflow produces spatially comparable, time-lapse velocity cross-sections formulated from disparate, discretely-acquired datasets. These practical steps aim to aid the use of the seismic refraction tomography method for the long-term monitoring of landslides prone to hydrological destabilization.

Whiteley, J. S.↗