At least 1,603 records · Page 89

Forest Irrigation of Tritiated Water: A Proven Tritiated Water Management Tool - 13357

Tritium releases from the Old Radioactive Waste Burial Ground (ORWBG) at the SRS in South Carolina has impacted groundwater and surface water. Tritiated groundwater plumes discharge into Fourmile Branch which is a small tributary of the Savannah River, a regional water resource. Taking advantage of the groundwater flow paths and the local topography a water collection and irrigation system was constructed and has been used at the SRS for over a decade to reduce these tritiated water releases to Fourmile Branch. The tritiated water is transferred to the atmosphere by evaporation from the pond surface, and after irrigation, wetted surface evaporation and evapotranspiration through the forest vegetation. Over the last decade SRS has irrigated over 120,000,000 gallons of tritiated water, which diverted over 6000 curies away from Fourmile Branch and the Savannah River. The system has been effective in reducing the flux of tritiated groundwater by approximately 70%. Mass balance studies of tritium in the forest soils before operations and over the last decade indicate that approximately 90% of the tritiated water that is irrigated is transferred to the atmosphere. Dose studies indicate that exposure to site workers and offsite maximally exposed individual is very low, approximately 6 mrem/year and 0.004 mrem/year, respectively. To consistently meet the flux reduction goal of tritium into Fourmile Branch optimization activities are proposed. These efforts will increase irrigation capacity and area. An additional 17 acres are proposed for an expansion of the area to be irrigated and a planting of approximately 40 acres of pine forest plantations is underway to expand irrigation capacity. Co-mingled with the tritiated groundwater are low concentrations of chlorinated volatile organic compounds (cVOCs), and 1,4-dioxane. Research studies and SRS field data indicate the forest irrigation system may have an added benefit of reducing the mass of these co-contaminants via degradation. This semi-passive system makes use of natural processes of hydrology and evapotranspiration to manage tritium-contaminated water by reducing its entrance into site streams and the Savannah River, as well as treating low levels of co-mingled VOCs. SRS expects to operate the system until the tritium decays to levels that represent a minimal impact to Fourmile Branch and the Savannah River, and meets the stakeholder expectations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Water-cooled Reactor Cavity Cooling System Flow Analysis

A research team at University of Wisconsin - Madison designed and constructed a 1/4 scaled experimental facility to study natural circulation cooling in a water based reactor cavity cooling system (WRCCS) for decay heat removal in an advanced high temperature reactor. The facility is capable of natural circulation operation scaled for simulated decay heat removal (up to 45 kW input power, which is equivalent to 1.70 MW at full scale) and pressurized up to 2 bar pressure. The WRCCS facility has been used to study natural circulation flow behavior from transients due to evaporation of the water inventory from decay heat removal. The natural circulation flow is observed to be oscillatory with the mean flow increasing as the pressure head in the system drops due to evaporation of the water inventory during two-phase operation. A first principles model was developed to understand the behavioral limits and trends. Through the use of void fraction measurements and the model, we find that the mass flow rate in the system increases due to small increases in the time-averaged void fraction over the course of a four-hour boil-off experiment. This increase in void fraction causes an increase in the buoyancy head and mass flow. The model also determines the operational limits on the mass flow rate under two-phase operation that can be verified with extended tests in the WRCCS facility. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Implementation of Increased Salt and Decreased Sludge Volumes in the Defense Waste Processing Facility - 19597

The Savannah River Site (SRS) Liquid Waste System (LWS) safely stores and treats high-level radioactive waste. The LWS consists of 51 waste storage tanks (eight of which are operationally closed and filled with grout), waste evaporators, treatment facilities, and solidification facilities such as the Defense Waste Processing Facility (DWPF) and Saltstone Production Facility (SPF). The disposition of high-level waste (HLW) into a glass waste form poured into canisters at the DWPF began in 1996. DWPF processed a sludge only flowsheet until 2008 when the Actinide Removal Process (ARP) and Modular Caustic Side Solvent Extraction Unit (MCU) began treating the salt waste from the underground liquid storage tanks by striking with monosodium titanate (MST) to remove actinides, when necessary to meet downstream acceptance criteria, and removing the MST and entrained sludge solids (SS) by filtration before using an organic solvent to strip the cesium from the salt, creating two new concentrated HLW streams. This change caused the DWPF to begin processing under both a sludge-only and a coupled operations flowsheet where salt streams would only be added when available. This strategy allows for continuous glass canister production at DWPF. Recently, DWPF completed a 10-month melter replacement in December 2017 and the Concentrate, Storage, and Transfer Facility (CSTF) has completed repairs to the 3H Evaporator system. These facility outages have caused delays in preparing the next batch of sludge feed for DWPF. Concurrent with these facility outages, the Salt Waste Processing Facility (SWPF) has been undergoing system testing and commissioning, working toward startup. SWPF is designed to process salt waste in the same manner as ARP/MCU, but with much higher throughput volumes produced per unit time. In order to process the SWPF salt streams efficiently, DWPF will implement a coupled operation only flowsheet. Based on the facility outages mentioned above, efforts have been made to identify strategies to minimize sludge volumes and maximize salt volumes in the DWPF until the next sludge batch is ready for processing in DWPF. Savannah River Remediation (SRR) recently performed an evaluation that examines the effects of reducing the volume of sludge and maximizing the addition of the cesium-rich concentrated salt solution in each Sludge Receipt and Adjustment Tank (SRAT) batch in order to extend the existing sludge batch as long as possible until the next sludge batch is ready. These effects include a reduction of weight percent solids in the DWPF processing vessels, an increase in cycle time, a new canister heat generation value that remains within regulatory limits, and higher gamma source that remains within bulk facility gamma shielding. Balancing the above parameters resulted in a small reduction of sludge volume per SRAT batch under SWPF operation and maximizing the salt volumes for both ARP/MCU and SWPF operation. This slight reduction in sludge volume and increase in salt volumes allows SRR to mitigate some of the schedule impact incurred by the facility outages. This strategy was evaluated for both ARP/MCU and SWPF operation. This strategy has been successfully implemented under ARP/MCU operation using small step changes in the current process. This paper provides an overview of the evaluation performed for DWPF with ARP/MCU and DWPF with SWPF operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Processing Technology for Radioactively Contaminated Water at Chernobyl Nuclear Power Plant - 19656

During the operation of the Chernobyl Nuclear Power Plant, distillation by evaporation was the main method for processing radioactively contaminated water. When the plant was decommissioned, the evaporation facility was mothballed and floor drain treatment was suspended in 2016. At present, the existing tanks with the capacity of 26,000 m{sup 3} are more than 60% full with radioactively contaminated floor drains, which requires alternative processing methods. The current process flow for radioactive waste management at State Specialized Enterprise 'Chernobyl NPP' includes processing of accumulated liquid radioactive wastes at a liquid radioactive wastes processing plant. Under the processing technology, liquid radioactive waste is immobilized at the plant by cementation and the resulting solid radioactive waste is then buried in a near-surface storage. Key factors for the selection of alternative radioactively contaminated water processing methods are the possibility to clear the processed water (no control monitoring), which requires the same degree of processing as for drinking water, and minimization of radioactive waste generation due to the lack of free space for solid waste disposal in the near-surface storage. Floor drains that require processing contain radionuclides such as {sup 137}Cs, {sup 90}Sr, {sup 60}Co and {sup 40}K. The current level of the total beta and gamma activity is about 4*105 Bq/kg. The following criteria are set for the Chernobyl NPP site for water to be disposed to the sewerage system: - Max. 37 Bq/kg for the total beta and gamma containing radionuclide activity; - Max. 0.7 Bq/kg for the total alpha containing radionuclide activity. METOIL produces inorganic sorbents for removing radionuclides from liquids and develops sorbent-based technology for a variety of applications related to liquid radioactive waste processing. In 2017-2018, experts from the Chernobyl NPP and METOIL ran several joint laboratory tests to evaluate the efficiency of inorganic sorbents made by METOIL for processing floor drains at the Chernobyl NPP. The test procedure included treatment of radioactively contaminated water in a two-stage sorption process: static sorption (sorbents are mixed in a liquid) and dynamic sorption (the liquid is filtered through a sorbent column). NIKET and MODIKS sorbents were provided for the tests. The results of the test measurements showed that the total alpha containing radionuclide activity is less than 0.026 Bq/kg and the total beta and gamma containing radionuclide activity is 9.2 Bq/kg. The physical and chemical parameters after processing also met the water disposal criteria. High sorption capacity of the sorbents used for the tests allows processing hundreds of water volumes with just one sorbent volume. At present, preparations are underway for full-scale tests at a pilot plant with a capacity of minimum 10 m{sup 3}/day. At a later stage, spent sorbents may be immobilized by inclusion into the cement matrix, which will substantially reduce the amount of radioactive waste to be buried. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Brine Availability Test in Salt, a Heated Borehole Experiment at the Waste Isolation Pilot Plant, New Mexico, USA - 20233

The Brine Availability Tests in Salt is a US Department of Energy Office of Nuclear Energy supported activity as part of the Spent Fuel and Waste Disposition Campaign where we are performing simultaneous heated and control experiments in adjacent horizontal boreholes in the WIPP Salt Disposal Investigation drifts as part of experimental Phase 1. Phase 1a of BATS, a low-cost, small spatial-scale experiment performed in order to design instrumentation and methods for further experimentation in the URL, has been completed (June 2018 - May 2019) and is described elsewhere. In coincidence with multiple physical parameters that will be measured over the duration of the experiment, we will be measuring the liquid and vapor phases of H{sub 2}O as well as its isotopic content (not measured in Phase 1a). Three different forms of water occur in natural salts: as fluid in macro scale (mm size) inclusions, as intergranular free H{sub 2}O and as H{sub 2}O incorporated in hydrous minerals. Each of these forms has potentially different stable isotope signatures and will be influenced differentially by heat induced transport and by interaction with introduced tracers. Continuous measurement of vapor phase H{sub 2}O isotopes during borehole heating will be impacted by several effects: 1) evaporation as liquid brine flows into the borehole and evaporates completely or partially into the dry N{sub 2} stream; 2) steam from dehydration of hydrous minerals, that may enter the borehole; and 3) hydrous minerals that may form in the borehole (preferentially incorporating heavier isotopes). The continuous time series collected over the course of the heating test will be combined with analyses of pre-test and post-test collected samples of test site salt to investigate the contributions of each of the three water types as H{sub 2}O is mobilized due to the effects of heating. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Implementation of the Glycolate Destruction Process with Sodium Permanganate in the Defense Waste Processing Facility (DWPF) - 20141

The Savannah River Site (SRS) seeks to replace formic acid with glycolic acid as a chemical reductant in the Defense Waste Processing Facility (DWPF), where borosilicate glass is mixed with high-level radioactive waste, melted at high temperatures, then poured into stainless steel canisters for safe storage. Prior research and development have demonstrated the feasibility and advantages of the new nitric-glycolic acid flowsheet over the current nitric-formic acid flowsheet to chemically adjust the radioactive sludge slurry waste in the Sludge Receipt and Adjustment Tank (SRAT) prior to vitrification. Use of glycolic acid reduces hydrogen and ammonia generation during the reduction process, thus reducing flammability hazards and purge requirements in the DWPF processing vessels. In addition, glycolic acid will support the new Salt Waste Processing Facility (SWPF) by allowing for receipt of higher volumes of waste due to reduction of flammable gases, increased boil-up rates in the vessels, and easing the processing of future sludge batches containing high levels of mercury. However, during DWPF operations, trace amounts of glycolate are anticipated to be entrained in the recycle stream and sent to the Concentration, Storage, and Transfer Facilities (CSTF) via the Recycle Collection Tank (RCT). The RCT receives condensate from the Slurry Mix Evaporator Condensate Tank (SMECT) and Off-gas Condensate Tank (OGCT) that may contain unreacted glycolate. A literature review found the potential for hydrogen generation due to thermolysis of glycolate in caustic CSTF conditions. Savannah River National Laboratory (SRNL) conducted several tests on simulant and radioactive waste from various tanks at SRS and confirmed that glycolate added to waste at concentrations of approximately 1000 mg/L and higher generates hydrogen through thermolysis. There are potential operating scenarios in the future where glycolate concentration could exceed 1000 mg/L in the 2H Evaporator Drop Tank, the highest accumulation point for DWPF organics received via recycle. These findings presented a need to develop another process to mitigate the impact of glycolic acid to the CSTF. Several DWPF compatible options were evaluated for their ability to destroy glycolate in the DWPF recycle stream under various processing conditions, thereby mitigating its introduction to the CSTF. Downselection testing identified sodium permanganate as the most promising and simplest option to oxidize glycolate. It has been demonstrated to be effective in various RCT simulant compositions, operating temperatures, oxidant addition rates, solution pH, and initial glycolate concentrations. A feasibility study identified existing tanks within the facility that could be used for receiving and storing the commercially available sodium permanganate, as well as feeding it to the RCT for processing. The use of existing equipment as well as the ability to purchase the pre-mixed chemical reduces implementation and operational complexity. The downstream impacts of the sodium permanganate reaction were also evaluated and demonstrated to have minimal impact on other chemical species present in the RCT and CSTF, as well as on the materials of construction of the RCT and CSTF vessels and associated piping and instrumentation. Future work is in progress to validate the glycolate destruction process with testing in actual radioactive RCT waste before implementation in DWPF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Savannah River Site High Level Radioactive Waste Tank Sample Thermolytic Hydrogen Generation - 20346

To support the revision of flammability calculations and controls for the Savannah River Site (SRS) High-Level Radioactive Waste (HLW) tanks, Savannah River National Laboratory (SRNL) conducted laboratory measurements with the goal of quantifying hydrogen produced in HLW by non-radiolytic chemical reactions (i.e., thermolysis). Testing was performed with HLW tank supernate samples that represented a cross section of types of waste at SRS, including tanks that store typical evaporator concentrate, dissolved salt-cake, dilute recycle stream from the Defense Waste Processing Facility (DWPF), evaporator concentrate of the recycle stream from DWPF, fresh waste from the canyon separations facility, and waste that has been through salt processing cesium removal. Non-radioactive simulant testing included the classes of organic compounds historically introduced into the HLW tanks that were recently shown to be the most active toward the thermolytic generation of hydrogen. The reaction rate equations developed for thermolytic hydrogen generation from each class of organic compound showed direct proportionality to organic compound concentration and hydroxide concentration. Simulant testing identified that highly concentrated waste with high hydroxide concentration had the highest rates of thermolytic hydrogen generation. Using the radioactive tank sample thermolysis measurements at high temperatures and the mechanistic salt dependence of the simulant models, a global model was developed for tank waste thermolytic hydrogen generation as a function of total organic carbon content of SRS HLW. Through the primary functionality of the global model (organic carbon and free hydroxide concentration), the relative reactivity of the organic carbon in the waste was quantified. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solubility Predictions for Hanford Tank Concentrates with HSC - 20459

The commercially available Outotec HSC 9.9.0{sup R} provides excellent predictions for the solubilities of many species for Hanford waste tank concentrates. The HSC solubility predictions with a Harvie activity model agreed well with five boildowns that showed solubility limits for NaNO{sub 3}, NaNO{sub 2}, Na{sub 2}CO{sub 3}, NaF, Na{sub 2}SO{sub 4}, and Na{sub 3}PO{sub 4}. However, the HSC did not predict density and therefore water content very well and therefore we used the measured densities and derived water content from the difference between measured density and assays. Furthermore, we adjusted the HSC enthalpy for the minor species Na{sub 3}PO{sub 4}*NaF double salt in order to fit the five boildowns as well. Previous work has shown that gibbsite becomes and remains supersaturated in all of these boildowns and so there was no alumina precipitation despite supersaturation. Furthermore, an equilibrium model like HSC always shows complete oxidation of any TOC in the presence of nitrate and nitrite. We therefore suppressed the HSC oxidation of acetate and oxalate in order to fit measured acetate and oxalate solubilities as TOC. Space in Hanford waste tanks is very limited and therefore evaporator campaigns continue to recover needed tank space from dilute tank liquids. Prior to each evaporator campaign, a boildown of a sample of tank liquid for each campaign provides a basis for planning by measuring density, water activity, soluble species, and solids precipitation as a function of concentration at 18 deg. C. These boildowns then provide validations and calibrations for the HSC solubility prediction for Hanford wastes. Previous work has shown the solubilities of minor electrolytes in these five boildowns follow rather simple power law solubility products. Hanford's 222-S laboratory has reported each of five boildowns for concentrated liquids from five waste tanks and tank blends. All boildowns eventually showed the precipitation of the dominant electrolyte, NaNO{sub 3}, and overall solution activity largely drives all solubility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling crud attachment on fuel surfaces - Role of interaction forces

Crud deposition is one of the major cause of fuel failures in PWRs operating in U.S. and around the world. Various experimental and computational studies have tried to relate thickness or amount of crud deposits to evaporative flux maps. Macroscopic models relating evaporation rate to deposition rate and the total amount of deposit, do not take into account shape of deposition patterns, interaction mechanisms between the crud particles and interactions between crud particles and substrate (in this case fuel surface). However, experimentally it is observed that there is spatiotemporal variation in the porosity and structure of crud layer deposits. It is also important to note that the deposition kinetics and the amount of deposits is highly dependent upon local or global chemistry which impact the interactions between particles and surfaces, and eventually effect attachment probability. The focus of this summary will be to present a model to describe the crud attachment kinetics on a fuel surface. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computational Study of Droplet Dynamics in Dispersed Flow Film Boiling Regime in PWR Geometries

Dispersed flow film boiling (DFFB) regime is exhibited during low-flooding rate conditions following the postulated Loss-of-Coolant Accident (LOCA) in nuclear reactor flow channels. LOCA is a type of design-basis accident scenario, which is crucial for reactor design and licensing. Accurate models to predict the heat transfer in DFFB regime is critical for the reactor to maintain safety limits. The nominal operating linear heat rate is also set based on the maximum linear heat rate determined for a LOCA transient. It is understood that the behavior of entrained droplets in DFFB regime greatly affects the heat transfer by evaporating and desuperheating the surrounding steam. Furthermore, interaction with flow structures also aids in increasing the evaporation rate of entrained droplets. In order to quantify this enhancement in heat transfer, the size of droplets downstream of flow structures (Spacer Grids and Mixing Vanes) is of crucial importance. Thermal hydraulic analysis codes like COBRA-TF, CATHARE-3 and adopt a three-field equation model that allows them to model the droplet field separately. However, to ensure the accuracy of these field equations, various correlations and physical models are required. This paper proposes a method for characterizing the mean Sauter Diameter of droplets across spacer-grids and mixing vanes in PWR sub-channels using PHASTA - a high fidelity flow solver with multiphase capabilities using the level-set method. The PHASTA code is a finite element based computational fluid dynamics code designed for solving compressible and incompressible turbulent flows. It has been demonstrated to be massively scalable (up to 786,432 cores), which is crucial for simulating large realistic domains. The code incorporates the level-set method for interface tracking of the gas-liquid interface.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Steam turbine materials and corrosion

Ultra-supercritical (USC) power plants offer the promise of higher efficiencies and lower emissions. Current goals of the U.S. Department of Energy’s Advanced Power Systems Initiatives include power generation from coal at 60% efficiency, which would require steam temperatures of up to 760°C. This project examines the steamside oxidation of candidate alloys for use in USC systems, with emphasis placed on applications in high- and intermediate-pressure turbines. As part of this research a concern has arisen about the possibility of high chromia evaporation rates of protective scales in the turbine. A model to calculate chromia evaporation rates is presented.

36 MATERIALS SCIENCE↗

Physical properties of bio-diesel & Implications for use of bio-diesel in diesel engines

In this study we identify components of a typical biodiesel fuel and estimate both their individual and mixed thermo-physical and transport properties. We then use the estimated mixture properties in computational simulations to gauge the extent to which combustion is modified when biodiesel is substituted for conventional diesel fuel. Our simulation studies included both regular diesel combustion (DI) and premixed charge compression ignition (PCCI). Preliminary results indicate that biodiesel ignition is significantly delayed due to slower liquid evaporation, with the effects being more pronounced for DI than PCCI. The lower vapor pressure and higher liquid heat capacity of biodiesel are two key contributors to this slower rate of evaporation. Other physical properties are more similar between the two fuels, and their impacts are not clearly evident in the present study. Future studies of diesel combustion sensitivity to both physical and chemical properties of biodiesel are suggested.

33 ADVANCED PROPULSION SYSTEMS↗

Thermal transport in CO2 laser irradiated fused silica: in situ measurements and analysis

In situ spatial and temporal temperature measurements of pristine fused silica surfaces heated with a 10.6 {micro}m CO{sub 2} laser were obtained using an infrared radiation thermometer based on a Mercury Cadmium Telluride (MCT) camera. Laser spot sizes ranged from 250 {micro}m to 1000 {micro}m diameter with peak axial irradiance levels of 0.13 to 16 kW/cm{sup 2}. For temperatures below 2800K, the measured steady-state surface temperature is observed to rise linearly with both increasing beam size and incident laser irradiance. The effective thermal conductivity estimated over this range was approximately 2W/mK, in good agreement with classical calculations based on phonon heat capacities. Similarly, time-dependent temperature measurements up to 2000K yielded thermal diffusivity values which were close to reported values of 7 x 10{sup -7} m{sup 2}/s. Above {approx}2800K, the fused silica surface temperature asymptotically approaches 3100K as laser power is further increased, consistent with the onset of evaporative heat losses near the silica boiling point. These results show that in the laser heating regime studied here, the T{sup 3} temperature dependent thermal conductivity due to radiation transport can be neglected, but at temperatures above 2800K heat transport due to evaporation must be considered. The thermal transport in fused silica up to 2800K, over a range of conditions, can then be adequately described by a linear diffusive heat equation assuming constant thermal properties.

36 MATERIALS SCIENCE↗

Physical properties of bio-diesel & Implications for use of bio-diesel in diesel engines

In this study we identify components of a typical biodiesel fuel and estimate both their individual and mixed thermo-physical and transport properties. We then use the estimated mixture properties in computational simulations to gauge the extent to which combustion is modified when biodiesel is substituted for conventional diesel fuel. Our simulation studies included both regular diesel combustion (DI) and premixed charge compression ignition (PCCI). Preliminary results indicate that biodiesel ignition is significantly delayed due to slower liquid evaporation, with the effects being more pronounced for DI than PCCI. The lower vapor pressure and higher liquid heat capacity of biodiesel are two key contributors to this slower rate of evaporation. Other physical properties are more similar between the two fuels, and their impacts are not clearly evident in the present study. Future studies of diesel combustion sensitivity to both physical and chemical properties of biodiesel are suggested.

33 ADVANCED PROPULSION SYSTEMS↗

Walmart Experimental Store Performance Stories: Preprint

Walmart opened two experimental stores--one in Colorado and one in Texas--in 2005 to serve as test beds for several advanced building systems. Each embodied more than 50 experiments covering materials, water systems, energy systems, and renewable energy production. Walmart worked for three years with the National Renewable Energy Laboratory for the Colorado Store and Oak Ridge National Laboratoryfor the Texas store to monitor, analyze, and report on their performance. HVAC experiments included waste oil boilers, a microturbine/absorption chiller combined heat and power system, evaporative cooling, and a transpired solar collector. The refrigeration systems integrated a medium-temperature secondary loop, evaporatively cooled condenser, doors on medium-temperature cases, andlight-emitting diodes on cases. Experiments in the lighting systems included a redesigned roof for clerestory daylighting and T-5 fluorescent lamps. Three photovoltaic systems for a total of 135 kW and a 50-kW wind turbine are also included. The energy system performance was compared to the measured performance of a prototypical Walmart store and to other benchmarks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Cloud-resolving and Limited Area Model Intercomparison Simulations using TWP-ICE Observations. Part 2: Rain Microphysics

Ten 3D cloud-resolving model (CRM) simulations and four 3D limited area model (LAM) simulations of an intense mesoscale convective system observed on January 23-24, 2006 during the Tropical Warm Pool – International Cloud Experiment (TWP-ICE) are compared with each other and with observations and retrievals from a scanning polarimetric radar, co-located UHF and VHF vertical profilers, and a Joss-Waldvogel disdrometer in an attempt to explain published results showing a low bias in simulated stratiform rainfall. Despite different forcing methodologies, similar precipitation microphysics errors appear in CRMs and LAMs with differences that depend on the details of the bulk microphysics scheme used. One-moment schemes produce too many small raindrops, which biases Doppler velocities low, but produces rain water contents (RWCs) that are similar to observed. Two-moment rain schemes with a gamma shape parameter (μ) of 0 produce excessive size sorting, which leads to larger Doppler velocities than those produced in one-moment schemes, but lower RWCs than observed. Two moment schemes also produce a convective median volume diameter distribution that is too broad relative to observations and thus, may have issues balancing raindrop formation, collision coalescence, and raindrop breakup. Assuming a μ of 2.5 rather than 0 for the raindrop size distribution improves one-moment scheme biases, and allowing μ to have values greater than 0 may improve two-moment schemes. Under-predicted stratiform rain rates are associated with under-predicted ice water contents at the melting level rather than excessive rain evaporation, in turn likely associated with convective detrainment that is too high in the troposphere and mesoscale circulations that are too weak. In addition to stronger convective updrafts than observed, limited domain size prevents a large, well-developed stratiform region from developing in CRMs, while a dry bias in ECMWF analyses does the same to the LAMs.

cloud-resolving↗

Influences of drizzle on stratocumulus cloudiness and organization [Influences of drizzle on cloudiness and stratocumulus organization]

Large-eddy simulations are used to study the influence of drizzle on stratocumulus organization, based on measurements made as part of the Second Dynamics and Chemistry of the Marine Stratocumulus field study-II. Cloud droplet number concentration ( N c ) is prescribed and considered as the proxy for different aerosol loadings. Our study shows that the amount of cloudiness does not decrease linearly with precipitation rate. An N c threshold is observed below which the removal of cloud water via precipitation efficiently reduces cloud depth, allowing evaporation to become efficient and quickly remove the remaining thin clouds, facilitating a fast transition from closed cells to open cells. Using Fourier analysis, stratocumulus length scales are found to increase with drizzle rates. Raindrop evaporation below 300 m lowers the cloud bases and amplifies moisture variances in the subcloud layer, while it does not alter the horizontal scales in the cloud layer, suggesting that moist cold pool dynamic forcings are not essential for mesoscale organization of stratocumulus. Furthermore, the cloud scales are greatly increased when the boundary layer is too deep to maintain well mixed.

54 ENVIRONMENTAL SCIENCES↗

CAUSES: Diagnosis of the Summertime Warm Bias in CMIP5 Climate Models at the ARM Southern Great Plains Site

Abstract All the weather and climate models participating in the Clouds Above the United States and Errors at the Surface project show a summertime surface air temperature (T2 m) warm bias in the region of the central United States. To understand the warm bias in long‐term climate simulations, we assess the Atmospheric Model Intercomparison Project simulations from the Coupled Model Intercomparison Project Phase 5, with long‐term observations mainly from the Atmospheric Radiation Measurement program Southern Great Plains site. Quantities related to the surface energy and water budget, and large‐scale circulation are analyzed to identify possible factors and plausible links involved in the warm bias. The systematic warm season bias is characterized by an overestimation of T2 m and underestimation of surface humidity, precipitation, and precipitable water. Accompanying the warm bias is an overestimation of absorbed solar radiation at the surface, which is due to a combination of insufficient cloud reflection and clear‐sky shortwave absorption by water vapor and an underestimation in surface albedo. The bias in cloud is shown to contribute most to the radiation bias. The surface layer soil moisture impacts T2 m through its control on evaporative fraction. The error in evaporative fraction is another important contributor to T2 m. Similar sources of error are found in hindcast from other Clouds Above the United States and Errors at the Surface studies. In Atmospheric Model Intercomparison Project simulations, biases in meridional wind velocity associated with the low‐level jet and the 500 hPa vertical velocity may also relate to T2 m bias through their control on the surface energy and water budget.

54 ENVIRONMENTAL SCIENCES↗