Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distributed Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Chapter Nine - Automated Optimal Control in Energy Systems: The Reinforcement Learning Approach

With the development of smart grid technologies an increasing number of new devices and participants have joined modern energy systems and are inevitably making them more complicated and interdependent than ever. Optimally controlling such a complex energy system and maintaining its operation in a high-efficient, secure, and resilient manner are challenging tasks to the system operators. Fortunately, the revolution in deep learning and artificial intelligence (AI), both from hardware and algorithms perspectives, has provided new ideas and solutions to many previously intractable problems. As a result, this advance in computer science also sparked great research interests in utilizing AI in solving engineering problems related to the modern energy systems. Among many AI techniques, deep reinforcement learning (DRL) has demonstrated great potential for solving sequential optimization problems, which are very common in the engineering domains. Its ability to handle nonlinearity and stochasticity in controlled systems has out-competed many traditional optimal control algorithms. Therefore in this chapter, we focus on the state-of-the-art of DRL concepts and related algorithms, compare their pros and cons with traditional optimal control approaches and discuss the typical workflow for leveraging RL in solving complex problems in modern energy systems.

artificial intelligence↗

In Situ Growth of Ni 2 P–Cu 3 P Bimetallic Phosphide with Bicontinuous Structure on Self-Supported NiCuC Substrate as an Efficient Hydrogen Evolution Reaction Electrocatalyst

A direct and effective approach is proposed to fabricate bimetallic phosphide Ni 2 P–Cu 3 P with controllable phase compn. and distribution for catalytic hydrogen evolution reaction (HER). Unlike previously reported precursors, a porous Ni-Cu alloy incorporated with graphitic carbon (NiCuC) prepd. via powder metallurgy is employed herein, and the generated Ni 2 P–Cu 3 P@NiCuC possesses a hierarchical porous structure and controllable phase compn. due to the high porosity and tunable Ni/Cu ratio of the precursor. With an optimal Cu content of 30.0 wt. %, the catalyst demonstrates the highest catalytic activity due to a synergistic interaction between different metallic phosphide sites and the facilitated mass transport. Meanwhile, d. functional theory (DFT) calcn. reveals that the at. interaction of Ni 2 P–Cu 3 P substantially lower the activation barrier for enhanced HER catalytic activity. Finally, the powder metallurgy provides an approach for the design of bimetallic phosphide electrocatalysts for HER and other catalytic applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distributed energy management for community microgrids considering network operational constraints and building thermal dynamics

A distributed energy management system for community microgrids is developed here. Unlike a centralized optimization-based energy management system, it schedules distributed energy resources and energy storage systems, as well as residential appliances, indirectly through iterative interaction between the microgrid central controller and home energy management systems, based on price signals. In each iteration, the microgrid central controller adjusts the scheduling of distributed energy resources and energy storage systems at the microgrid level. Meanwhile, the home energy management system of each house adjusts the scheduling of residential appliances. Then, the energy price at each bus is updated according to the unbalanced power between generation and demand. The optimization converges when the unbalanced power of all buses is close to zero, i.e., the microgrid central controller and home energy management systems reach an agreement on the energy price and generation/consumption. In particular, a detailed thermal dynamic model of the house is integrated into the HEMS scheduling for intelligent control of the heating, ventilation, and air-conditioning system by customers. Lastly, the distribution network is also considered to make the energy price signal locational. Results of case studies validate the efficacy of the proposed distributed energy management system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced, Integrated Control for Building Operations to Achieve 40% Energy Saving

We developed and demonstrated a software based integrated advanced building control platform called Smart Energy Box (SEB), which can coordinate building subsystem controls, integrate variety of energy optimization algorithms and provide proactive and collaborative energy management and control for building operations using weather and occupancy information. The integrated control system is a low cost solution and also features: Scalable component based architecture allows to build a solution for different building control system configurations with needed components; Open Architecture with a central data repository for data exchange among runtime components; Extendible to accommodate variety of communication protocols. Optimal building control for central loads, distributed loads and onsite energy resource; uses web server as a loosely coupled way to engage both building operators and building occupants in collaboration for energy conservation. Based on the open platform of SEB, we have investigated and evaluated a variety of operation and energy saving control strategies on Carnegie Mellon University Intelligent Work place which is equipped with alternative cooling/heating/ventilation/lighting methods, including radiant mullions, radiant cooling/heating ceiling panels, cool waves, dedicated ventilation unit, motorized window and blinds, and external louvers. Based on the validation results of these control strategies, they were integrated in SEB in a collaborative and dynamic way. This advanced control system was programmed and computer tested with a model of the Intelligent Workplace's northern section (IW n ). The advanced control program was then installed in the IW n control system; the performance was measured and compared with that of the state of the art control system to verify the overall energy savings great than 40%. In addition advanced human machine interfaces (HMI's) were developed to communicate both with building occupants and the building operator. Lifecycle cost analyses of the advanced building control were performed, and a Building Control System Guide was prepared and published to inform owners, architects, and engineers dealing with new construction or renovation of buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Control of the Obstacle Problem in a Perforated Domain

We study the problem of optimally controlling the solution of the obstacle problem in a domain perforated by small periodically distributed holes. The solution is controlled by the choice of a perforated obstacle which is to be chosen in such a fashion that the solution is close to a given profile and the obstacle is not too irregular. We prove existence, uniqueness and stability of an optimal obstacle and derive necessary and sufficient conditions for optimality. When the number of holes increase indefinitely we determine the limit of the sequence of optimal obstacles and solutions. This limit depends strongly on the rate at which the size of the holes shrink.

97 MATHEMATICS AND COMPUTING↗

Software-Based Challenges of Developing the Future Distribution Grid

The software that the utility industry currently uses may be insufficient to analyze the distribution grid as it rapidly modernizes to include active resources such as distributed generation, switch and voltage control, automation, and increasingly complex loads. Although planners and operators have traditionally viewed the distribution grid as a passive load, utilities and consultants increasingly need enhanced analysis that incorporates active distribution grid loads in order to ensure grid reliability. Numerous commercial and open-source tools are available for analyzing distribution grid systems. These tools vary in complexity from providing basic load-flow and capacity analysis under steady-state conditions to time-series analysis and even geographical representations of dynamic and transient events. The need for each type of analysis is not well understood in the industry, nor are the reasons that distribution analysis requires different techniques and tools both from those now available and from those used for transmission analysis. In addition, there is limited understanding of basic capability of the tools and how they should be practically applied to the evolving distribution system. The study reviews the features and state of the art capability of current tools, including usability and visualization, basic analysis functionality, advanced analysis including inverters, and renewable generation and load modeling. We also discuss the need for each type of distribution grid system analysis. In addition to reviewing basic functionality current models, we discuss dynamics and transient simulation in detail and draw conclusions about existing software?s ability to address the needs of the future distribution grid as well as the barriers to modernization of the distribution grid that are posed by the current state of software and model development. Among our conclusions are that accuracy, data transfer, and data processing abilities are key to future distribution grid modeling, and measured data sources are a key missing element . Modeling tools need to be calibrated based on measured grid data to validate their output in varied conditions such as high renewables penetration and rapidly changing topology. In addition, establishing a standardized data modeling format would enable users to transfer data among tools to take advantage of different analysis features. ?

99 GENERAL AND MISCELLANEOUS↗

Security Constrained Economic Optimization of Photovoltaic and Other Distributed Assets

The rapid growth of distributed energy resources (DERs), especially photovoltaic (PV) systems, has introduced new complexities in maintaining grid reliability, stability, and cost-effective operation. This project addresses these challenges by developing and demonstrating a scalable GridOS Distributed Energy Resource Management System (DERMS) that enables secure, real-time optimization and control of DERs at the distribution feeder level.

14 SOLAR ENERGY↗

DERMS Online: A New Voltage Sensitivity-Enabled Feedback Optimization Framework: Preprint

This paper proposes a distributed energy resource management system (DERMS) solution by developing a new voltage sensitivity enabled feedback optimization framework. The key idea is to adopt a measurement feedback scheme to reformulate the original nonlinear optimization into a linear programming (LP) problem via perturb and observe-based voltage sensitivity analysis. The proposed solution eliminates the dependence on load knowledge and can be implemented online thanks to an efficient open-source solver for LP problems. The proposed DERMS online platform is generalizable to deal with various types of distributed energy resources (DERs), including distributed photovoltaics (PVs), energy storage, electric vehicles, demand response, etc. Comparison results with other control methods on a realistic distribution feeder in Southern California highlight the feasibility as well as benefits for the proposed framework.

distributed energy resources management↗

Performance Evaluation of Distributed Energy Resource Management Systems Using Software- and Hardware-in-the-Loop

Distributed energy resource management systems (DERMS) are an important emerging technology for coordinating distributed energy resources (DERs) integrated in power distribution networks. These solutions implement a software platform to monitor, control, and coordinate DERs in real time to provide aggregate grid services to the electric utility or distribution system operator. To move DERMS technology forward, research and performance validation in a laboratory environment are needed to ensure proper function of DERMS prior to field deployment. This presentation presents a generic hardware-in-the-loop (HIL) platform to evaluate performance of DERMS using software-in-the-loop (SIL) and power HIL. The platform provides realistic testing in a laboratory environment, including accurate modeling of full-scale distribution systems, DERMS software controllers, and at-power distributed energy resources (DERs), such as solar and battery inverters. Two case studies are presented to demonstrate how the platform can be used independently as an integrated development and validation approach for different projects. Laboratory testing results are included to showcase the voltage regulation performance of each study and the benefits of implementing such a platform for DERMS evaluation.

DERMS↗

Conceptual design of inverted core lead bismuth eutectic fast reactor for marine applications

The development of an inverted core fast reactor aims to generate 60 MWth for about 30 Effective Full Power Years without refueling. The reactor design is a transportable reactor using UO{sub 2} fuel and lead-bismuth-eutectic cooled designed for marine applications and is intended to improve the reactor performances compared to the normal core design: better condition for passive cooling system capability by lower core pressure drop, taking advantage of potential power uprate from the lower maximum fuel temperature. Systematic design processes are presented in this work: fuel pin geometry selection, fuel assembly (FA) design, and core design. A relationship between pressure drops, coolant velocity, maximum fuel temperature, coolant channel diameter, and fuel volume fraction was introduced in a single graph used as a tool to select fuel pin geometry. Fuel fabrication capability also took place in consideration of FA design which led to 7 holes per FA, and two-dimensional temperature distribution studies were also carried out. Core design processes including radial zoning, axial zoning, and core optimization were conducted using Monte Carlo code MCS, which is UNIST CORE laboratory in-house code. The current core design uses 3 fuel enrichment levels and 3 FA types to control the local power distribution and power shift during its lifetime. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect of Control Blade History, and Axial Coolant Density and Burnup Profiles on BWR Burnup Credit

A technical basis for peak reactivity boiling water reactor (BWR) burnup credit (BUC) methods was recently generated, and the technical basis for extended BWR BUC is now being developed. In this paper, a number of effects related to extended BWR BUC are analyzed, including three major operational effects in BWRs: the coolant density axial distribution, the use of control blades during operation, and the axial burnup profile. Specifically, uniform axial moderator density profiles are analyzed and compared to previous results and an additional temporal fidelity study combing moderator density profiles for three different fuel assemblies is presented. Realistic control blade histories and cask criticality results are compared to previously generated constructed control blade histories. Finally, a preliminary study of the axial burnup profile is provided.

Marshall, William BJ J↗

Results of the implementation on a mock-up of the full 3dB hybrid matching option of the ITER ICRH system

Each of the two ICRH antennas for ITER must couple 20MW to the plasma in the 40-55MHz band via an array of 24 radiating shorted straps fed by four generators. The matching system must provide automatic matching control on the mean load provided by the plasma and be resilient (parallel {Gamma}{sub G} parallel <0.2) to a wide range of fast antenna load excursions occurring in ELMy plasmas. Furthermore, good control of the current distribution in the strap array must be possible for the various heating and current drive scenarios. Two load resilient matching options have been considered for ITER: the 4 'Conjugate-T'(CT) and the 4 hybrids ones, the first being presently considered as a back-up option. Automatic control of these 2 options has been developed, and tested for optimization on a low-powered scaled mock-up. Successful implementation of the simultaneous feedback control of 11 actuators for the matching of the 4 CT and for the control of the toroidal phasing has already been achieved. The matching and the array current control of the 3dB hybrid option are provided by simultaneous feedback control of the decouplers and double stub tuners (in total 23 actuators) and this has also been successfully achieved for the full array. The paper discusses the circuit implementation and presents the obtained results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Practical Secondary Control for Hardware Microgrids: Preprint

Practical vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids (MGs) with multiple grid-forming (GFM) inverter-based resources (IBRs) have not yet been developed. Therefore, this paper proposes a generic and vendor-agnostic secondary control architecture that works with all GFM IBRs and synchronous generators. This secondary control does not need to employ any additional measurement devices in the MG and uses the inherent communication systems of the GFM units, such as Modbus TCP/IP. The practical challenges of Modbus holding registers such as packet loss, quantization error, etc. and their deteriorating impacts on the secondary control action are investigated. The proposed three-stage modification of any secondary control architecture to eliminate these impacts includes 1) averaging the data read, 2) situational event-triggering of the controller, and 3) the finite iteration of the controlling action. The proposed method is validated using a laboratory hardware MG with commercial GFM units.

inverter based resources↗

Asynchronous Grid Connections Providing Fast-Frequency Response: System Integration Study

This paper presents an integration study for the recent power electronic-based fast-frequency response technology, "asynchronous grid connection" which operates as an aggregator for behind-the-meter resources and distributed generators. Both technical feasibility and techno-economic viability studies are presented. The fast-frequency response characteristics, validated against Power Hardware-in-the-Loop experiments, are integrated into an IEEE 9- bus system in DigSilent PowerFactory for system-level dynamic analysis. It demonstrates that droop-based control enhancements to local distributed generators allow their aggregation to provide grid-supporting functionalities and participate in the ancillary service markets. To this end, a long-term simulation embedding the system within the ancillary service market framework of PJM has been performed. The fast-frequency response regulation is subsequently used to calculate the potential revenue and project the results on a 15-year investment horizon. Finally, the techno-economic analysis provides recommendations for enhancements to access the full potential of distributed generators on a technical and regulatory level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fueling Studies on the Lithium Tokamak Experiment

Lithium plasma facing components reduce the flux of "recycled" particles en- tering the plasma edge from the plasma facing components. This results in increased external fueling requirements and provides the opportunity to control the magnitude and distribution of the incoming particle flux. It has been pre- dicted that the plasma density profile will then be determined by the deposition profile of the external fueling, rather than dominated by the recycled particle flux. A series of experiments on the Lithium Tokamak Experiment demonstrate that lithium wall coatings facilitate control of the neutral and plasma particle in- ventories. With fresh lithium coatings and careful gas injection programming, over 90% of the injected particle inventory can be absorbed in the lithium wall during a discharge. Furthermore, dramatic changes in the fueling requirements and plasma parameters were observed when lithium coatings were applied. This is largely due to the elimination of water as an impurity on the plasma facing components. A Molecular Cluster Injector (MCI) was developed for the fueling of LTX plas- mas. The MCI uses a supersonic nozzle, cooled to liquid nitrogen temperatures, to create the conditions necessary for molecular cluster formation. It has been predicted that molecular clusters will penetrate deeper into plasmas than gas- phase molecules via a reduced ionization cross-section and by improving the collimation of the neutral jet. Using an electron beam diagnostic, the densities of the cryogenic MCI are measured to be an order of magnitude higher than in the room-temperature jets formed with the same valve pressure. This indi- cates increased collimation relative to what would be expected from ideal gas dynamics alone. A systematic study of the fueling efficiencies achieved with the LTX fueling systems is presented. The fueling efficiency of the Supersonic Gas Injector (SGI) is demonstrated to be strongly dependent on the distance between the nozzle and plasma edge. The fueling efficiency of the gas puffer was improved by the addition of a guide tube to keep the gas flow collimated and directed towards the plasma edge. Contrary to results reported on other devices, the MCI yields fueling efficiencies that are at best equal to the SGI. This suggests that any enhanced penetration from cluster formation is nullified by the reduced velocity of the cryogenic gas. Furthermore, at very high neutral fluxes, the fueling efficiency of the MCI dropped off dramatically, suggesting that the build-up of pressure in the scrape-off-layer is producing a self-shielding effect. All of these results are consistent with the idea that the best gas-based fueling source is one that brings highly directed neutrals to the plasma edge, without being scattered or ionized in the scrape-off-layer. The density profiles of LTX plasmas are measured during external fueling with the gas puffer, SGI, and cryogenic MCI. While the density profile amplitude increases with higher fueling rates, the shape of the profile remains constant. This suggests that particle transport is such that differences in the neutral deposition cannot be discerned. The density profiles are consistently hollow, suggesting a region of reduced particle transport in the core of LTX plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MAVNet: Design of a Reliable Beyond Visual Line of Sight Communication System for Unmanned Vehicles

This paper details the design and system components of the Multi-Modal Autonomous Vehicle Network system (MAVNet). MAVNet was designed to provide reliable and redundant command, control and payload data distribution for unmanned vehicles operating beyond visual line of sight. Current industry solutions do not adequately solve key networking challenges, do not support network diversity and fall short of providing desirable next-generation requirements including data fusion from national air space data sources, multi-pilot and multi-agent control. The MAVNet system and the approach taken to solve these issues will be detailed in this paper.

Stinson, Brad J↗

Recent Experience with a Hybrid SCADA/PMU On-Line State Estimator

PMU devices are expected to grow in number from a few to several hundreds in the next five years. Some relays are already global positioning system-capable and could provide the same type of data as any PMU. This introduces a new paradigm of very fast accurate synchrophasor measurements from across the grid in real-time that augment and parallel existing slower SCADA measurements. Control center applications will benefit from this PMU data; for example, use of PMU data in state estimation is expected to improve accuracy and robustness, which in turn will result in more timely and accurate N-1 security analysis, resulting in an overall improvement of grid system reliability and security. This paper describes results from a recent implementation of this technology, the benefits and future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗