At least 1,603 records · Page 89

Real-time data processing and magnetic field pitch angle estimation of the JET motional Stark effect diagnostic based on Kalman filtering

A novel technique for the real-time measurement of the magnetic field pitch angle in JET discharges using the motional Stark effect diagnostic is presented. Kalman filtering techniques are adopted to estimate the amplitude of the avalanche photodiode signals' harmonics that are relevant for the pitch angle calculation. The proposed technique {l_brace}for extended technical details of the generic algorithm see [R. Coelho and D. Alves, IEEE Trans. Plasma Sci. 37, 164 (2009)]{r_brace} is shown to be much more robust and provides less noisy estimates than an equivalent lock-in amplifier scheme, in particular when dealing with edge localized modes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Role of Anthropomorphic Phantoms in Diagnostic Ultrasound Imaging for Disease Characterization

An anthropomorhic phantom is an object that can mimic a region of the human anatomy. Anthropomorphic phantoms have a variety of roles in diagnostic ultrasound. These roles include quality assurance testing of ultrasound machines, calibration and testing of new imaging techniques, training of sonographers, and--most importantly--use as a tool to obtain a better understanding of disease progression in the relevant anatomy. To be anthropomorphic a phantom must accurately mimic the body in terms of its ultrasonic and mechanical properties, as well as anatomically. The acoustic properties are speed of sound, attenuation, and backscatter. The mechanical properties are elasticity and density. Phantoms are constructed from tissue-mimicking materials (TMMs). TMMs are prepared from a variety of ingredients, such as gelatine, agar, safflower oil, and glass beads. These ingredients are then boiled and cooled under controlled conditions to produce a solid TMM. To determine if the TMM has the correct acoustic properties, acoustic measurements are performed using a scanning acoustic macroscope. Mechanical measurements are also performed to test the elasticity and density properties. TMMs with the correct properties are subsequently put through a series of moulding procedures to produce the anthropomorphic phantom.

36 MATERIALS SCIENCE↗

Determination of Radiation Energy Response for Thermoluminescent Dosimeter TLD-100: Determination of Organ Dose in Diagnostic Radiology

TLD-100 (thermoluminescent dosimeter) cards (chips) were calibrated using X-rays with energies of 25-250 kV produced by a Cs-137 source. The energy responses of lithium fluoride crystals for different energies of X-rays were studied. QA/QC was then performed in the Albanian Ionizing Radiation Metrology Laboratory. Based on the QA/QC results, the chips were used to study the doses to different organs in diagnostic radiology. Organ dose was evaluated after calculation of e dose in air (Kair), using an ionizing chamber.

61 RADIATION PROTECTION AND DOSIMETRY↗

Antenna design for fast ion collective Thomson scattering diagnostic for the international thermonuclear experimental reactor

Fast ion physics will play an important role for the international thermonuclear experimental reactor (ITER), where confined alpha particles will affect and be affected by plasma dynamics and thereby have impacts on the overall confinement. A fast ion collective Thomson scattering (CTS) diagnostic using gyrotrons operated at 60 GHz will meet the requirements for spatially and temporally resolved measurements of the velocity distributions of confined fast alphas in ITER by evaluating the scattered radiation (CTS signal). While a receiver antenna on the low field side of the tokamak, resolving near perpendicular (to the magnetic field) velocity components, has been enabled, an additional antenna on the high field side (HFS) would enable measurements of near parallel (to the magnetic field) velocity components. A compact design solution for the proposed mirror system on the HFS is presented. The HFS CTS antenna is located behind the blankets and views the plasma through the gap between two blanket modules. The viewing gap has been modified to dimensions 30x500 mm{sup 2} to optimize the CTS signal. A 1:1 mock-up of the HFS mirror system was built. Measurements of the beam characteristics for millimeter-waves at 60 GHz used in the mock-up agree well with the modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray Spectroscopy of the Radiation-Driven Winds of Massive Stars: Line Profile and Line Ratio Diagnostics

Massive stars drive powerful, supersonic winds via the radiative momentum associated with the thermal UV emission from their photospheres. Shock phenomena are ubiquitous in these winds, heating them to millions, and sometimes tens of millions, of degrees. The emission line spectra from the shock-heated plasma provide powerful diagnostics of the winds' physical conditions, which in turn provide constraints on models of wind shock heating. Here I show how x-ray line transfer is affected by photoelectric absorption in the partially ionized component of the wind and how it can be modeled to determine the astrophysically important mass-loss rates of these stellar winds. I also discuss how photoexcitation out of metastable excited levels of helium-like ions can provide critical information about the location of the hot plasma in magnetically channeled massive star winds.

79 ASTRONOMY AND ASTROPHYSICS↗

Pr{sup 3+}-doped fluoro-oxide lithium glass as scintillator for nuclear fusion diagnostics

Experimental results are presented on the neutron scintillating properties of a custom-designed Pr3+(praseodymium)-doped lithium (Li) glass. Luminescence was observed at 278 nm wavelength, originating from the 5d-4f transition. Time-resolved measurements yielded about 20 ns decay times for ultraviolet and x-ray excitation while much faster decay times of about 6 ns were observed for alpha particle and neutron excitation. Actual time-of-flight data in laser fusion experiments at the GEKKO XII facility of the Institute of Laser Engineering, Osaka University reveal that it can clearly discriminate fusion neutrons from the much stronger x-rays signals. This material can promise improved accuracy in future scattered neutron diagnostics.

36 MATERIALS SCIENCE↗

Operation and upgrade of diagnostic neutral beam injector RUDI at TEXTOR tokamak

The status and the executing modernization of RUssian Diagnostic Injector (RUDI) are described. The ion source consists of arc plasma emitter and multiaperture four-electrode ion optical system. The present ion optical system with round beamlets is to be replaced by new slit apertures system for the reducing beam angular divergence in one direction. Due to enlarged dimensions and transparency of new ion optical system the extracted ion beam current will be by 50% increased. For the extension of beam pulse duration from 4 s to 8-10 s an optimized metal-ceramic arc-discharge channel is introduced. In the paper, the optical measurements results of beam parameters, including the profile of species distribution, scanned by custom-built multichannel spectroscope, are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics design of a 100 keV acceleration grid system for the diagnostic neutral beam for international tokamak experimental reactor

This paper describes the physics design of a 100 keV, 60 A H{sup -} accelerator for the diagnostic neutral beam (DNB) for international tokamak experimental reactor (ITER). The accelerator is a three grid system comprising of 1280 apertures, grouped in 16 groups with 80 apertures per beam group. Several computer codes have been used to optimize the design which follows the same philosophy as the ITER Design Description Document (DDD) 5.3 and the 1 MeV heating and current drive beam line [R. Hemsworth, H. Decamps, J. Graceffa, B. Schunke, M. Tanaka, M. Dremel, A. Tanga, H. P. L. De Esch, F. Geli, J. Milnes, T. Inoue, D. Marcuzzi, P. Sonato, and P. Zaccaria, Nucl. Fusion 49, 045006 (2009)]. The aperture shapes, intergrid distances, and the extractor voltage have been optimized to minimize the beamlet divergence. To suppress the acceleration of coextracted electrons, permanent magnets have been incorporated in the extraction grid, downstream of the cooling water channels. The electron power loads on the extractor and the grounded grids have been calculated assuming 1 coextracted electron per ion. The beamlet divergence is calculated to be 4 mrad. At present the design for the filter field of the RF based ion sources for ITER is not fixed, therefore a few configurations of the same have been considered. Their effect on the transmission of the electrons and beams through the accelerator has been studied. The OPERA-3D code has been used to estimate the aperture offset steering constant of the grounded grid and the extraction grid, the space charge interaction between the beamlets and the kerb design required to compensate for this interaction. All beamlets in the DNB must be focused to a single point in the duct, 20.665 m from the grounded grid, and the required geometrical aimings and aperture offsets have been calculated.

43 PARTICLE ACCELERATORS↗

Diagnostic experiments at a 3 MeV test stand at Rutherford Appleton Laboratory (United Kingdom)

A front end is currently under construction consisting of a H{sup -} Penning ion source (65 keV, 60 mA), low energy beam transport (LEBT), and radio frequency quadrupole (3 MeV output energy) with a medium energy beam transport suitable for high power proton applications. Diagnostics can be divided either in destructive techniques such as beam profile monitor, pepperpot, slit-slit emittance scanner (preferably used during commissioning) or nondestructive, permanently installed devices such as photodetachment-based techniques. Another way to determine beam distributions is a scintillator with charge-coupled device camera. First experiments have been performed to control the beam injection into the LEBT. The influence of beam parameters such as particle energy and space-charge compensation on the two-dimensional distribution and profiles will be presented.

43 PARTICLE ACCELERATORS↗

A 130 point Nd:YAG Thomson scattering diagnostic on MAST

A Thomson scattering diagnostic designed to measure both edge and core physics has been implemented on MAST. The system uses eight Nd:YAG lasers, each with a repetition rate of 30 Hz. The relative and absolute timing of the lasers may be set arbitrarily to produce fast bursts of measurements to suit the time evolution of the physics being studied. The scattered light is collected at F/6 by a 100 kg six element lens system with an aperture stop of 290 mm. The collected light is then transferred to 130 polychromators by 130 independent fiber bundles. The data acquisition and processing are based on a distributed computer system of dual core processors embedded in 26 chassis. Each chassis is standalone and performs data acquisition and processing for five polychromators. This system allows data to be available quickly after the MAST shot and has potential for real-time operations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-point motional Stark effect diagnostic for Madison Symmetric Torus

A high-precision spectral motional Stark effect (MSE) diagnostic provides internal magnetic field measurements for Madison Symmetric Torus (MST) plasmas. Currently, MST uses two spatial views - on the magnetic axis and on the midminor (off-axis) radius, the latter added recently. A new analysis scheme has been developed to infer both the pitch angle and the magnitude of the magnetic field from MSE spectra. Systematic errors are reduced by using atomic data from atomic data and analysis structure in the fit. Reconstructed current density and safety factor profiles are more strongly and globally constrained with the addition of the off-axis radius measurement than with the on-axis one only.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a nine spatial point, multipulse Thomson scattering diagnostic

A Thomson scattering diagnostic has been developed for the C-2 field-reversed configuration device. Based on a multipulse ruby laser, the system measures the electron temperature at nine spatial points. These points are chosen from 22 selectable positions covering r{approx_equal}1-41 cm. Twin collection lenses couple the scattered photons to nine optical fiber pairs. Extra fiber lengths delay the signals from different spatial points relative to each other, allowing up to three points to be analyzed by a single polychromator. The polychromator, using compact photomultipliers as detectors, has six spectral channels covering the range of 685-725 nm and is able to estimate electron temperatures of {approx_equal}10-200 eV. The photomultiplier output signals are recorded by digital storage oscilloscopes integrated with the main MDSplus database, with temperature and error estimates generated automatically at the conclusion of each plasma discharge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extended fast-ion D-alpha diagnostic on DIII-D

A fast-ion deuterium-alpha (FIDA) diagnostic, first commissioned on DIII-D in 2005, relies on Doppler-shifted light from charge-exchange between beam neutrals and energetic ions. The second generation (2G) system was installed on DIII-D in 2009. Its most obvious improvement is the spatial coverage with 11 active in-beam and three passive off-beam views; the latter allows for simultaneous monitoring of the background signal. Providing extended coverage in fast-ion velocity space, the new views possess a more tangential component with respect to the toroidal field compared to their first generation counterparts. Each viewing chord consists of a bundle of three 1.5 mm core fibers to maximize light gathering. For greater throughput, fast f/1.8 optical components are used throughout. The signal is transmitted via fiber optics to a patch panel, so the user is able to choose the detector. FIDA was originally installed with a spectrometer and charge-coupled device (CCD) camera to monitor the full D{sub {alpha}} spectrum for two spatial views. 2G adds another spectrometer and CCD that monitor the blue-shifted wing for six spatial views at 1 kHz. In addition, a photomultiplier tube and fast digitizer provide wavelength-integrated signals at 1 MHz for eight spatial views.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a cavity ring-down spectroscopy diagnostic for negative ion rf source SPIDER

The rf source test facility SPIDER will test and optimize the source of the 1 MV neutral beam injection systems for ITER. Cavity ring-down spectroscopy (CRDS) will measure the absolute line-of-sight integrated density of negative (H{sup -} and D{sup -}) ions, produced in the extraction region of the source. CRDS takes advantage of the photodetachment process: negative ions are converted to neutral hydrogen atoms by electron stripping through absorption of a photon from a laser. The design of this diagnostic is presented with the corresponding simulation of the expected performance. A prototype operated without plasma has provided CRDS reference signals, design validation, and results concerning the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic diagnostics for liquid lithium divertor studies on National Spherical Torus Experiment

The use of lithium-coated plasma facing components for plasma density control is studied in the National Spherical Torus Experiment (NSTX). A recently installed liquid lithium divertor (LLD) module has a porous molybdenum surface, separated by a stainless steel liner from a heated copper substrate. Lithium is deposited on the LLD from two evaporators. Two new spectroscopic diagnostics are installed to study the plasma surface interactions on the LLD: (1) A 20-element absolute extreme ultraviolet (AXUV) diode array with a 6 nm bandpass filter centered at 121.6 nm (the Lyman-{alpha} transition) for spatially resolved divertor recycling rate measurements in the highly reflective LLD environment, and (2) an ultraviolet-visible-near infrared R=0.67 m imaging Czerny-Turner spectrometer for spatially resolved divertor D I, Li I-II, C I-IV, Mo I, D{sub 2}, LiD, CD emission and ion temperature on and around the LLD module. The use of photometrically calibrated measurements together with atomic physics factors enables studies of recycling and impurity particle fluxes as functions of LLD temperature, ion flux, and divertor geometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An upgraded x-ray spectroscopy diagnostic on MST

An upgraded x-ray spectroscopy diagnostic is used to measure the distribution of fast electrons in MST and to determine Z{sub eff} and the particle diffusion coefficient D{sub r}. A radial array of 12 CdZnTe hard-x-ray detectors measures 10-150 keV Bremsstrahlung from fast electrons, a signature of reduced stochasticity and improved confinement in the plasma. A new Si soft-x-ray detector measures 2-10 keV Bremsstrahlung from thermal and fast electrons. The shaped output pulses from both detector types are digitized and the resulting waveforms are fit with Gaussians to resolve pileup and provide good time and energy resolution. Lead apertures prevent detector saturation and provide a well-known etendue, while lead shielding prevents pickup from stray x-rays. New Be vacuum windows transmit >2 keV x-rays, and additional Al and Be filters are sometimes used to reduce low energy flux for better resolution at higher energies. Measured spectra are compared to those predicted by the Fokker-Planck code CQL3D to deduce Z{sub eff} and D{sub r}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast spectroscopy diagnostic to measure localized ion temperature and toroidal velocity fluctuations

A dual-channel high-efficiency, high-throughput custom spectroscopic system has been designed and implemented at DIII-D to measure localized ion thermal fluctuations associated with drift wave turbulence. A large-area prism-coupled transmission grating and high-throughput collection optics are employed to observe C VI emission centered near {lambda}=529 nm. The diagnostic achieves 0.25 nm resolution over a 2.0 nm spectral band via eight discrete spectral channels. A turbulence-relevant time resolution of 1 {mu}s is achieved using cooled high-speed avalanche photodiodes and ultralow-noise preamplifiers. The system sensitivity is designed to provide measurements of normalized ion temperature fluctuations on the order of {delta}T{sub i}/T{sub i}{<=}1%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design criteria of the bolometer diagnostic for steady-state operation of the W7-X stellarator

A bolometric diagnostic system with features necessary for steady-state operation in the superconducting stellarator W7-X was designed. During a pulse length of 1800 s with an ECRH (electron cyclotron resonance heating) power of 10 MW, the components suffer not only from a large thermal load but also from stray radiation of the nonabsorbed isotropic microwaves. This paper gives an overview of the technical problems encountered during the design work and the solutions to individual problems to meet the special requirements in W7-X, e.g., component thermal protection, detector offset thermal drift suppression, as well as a microwave shielding technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗