Assessment of Methods to Control Invasive Reed Canarygrass (Phalaris arundinacea) in Tidal Freshwater Wetlands

Controlling non-native invasive species is a significant challenge facing natural area managers in North America and around the world. Reed canarygrass (Phalaris arundinacea), is invasive in temperate freshwater wetlands throughout the United States and Canada. While methods for the prevention or elimination of reed canarygrass are generally well established, methods suitable for the unique conditions in tidal wetlands remain poorly understood. Namely, prolonged inundation of tidal wetlands for control purposes may only be accomplished with a concomitant loss of habitat connectivity and other functions. Restoration practitioners aiming to design self-sustaining wetlands in the lower Columbia River and estuary, on the northwestern Pacific Coast, have found that reed canarygrass is widespread and quick to establish throughout the 176-river-kilometer tidal freshwater floodplain. Here we report the results of a comprehensive effort to develop the knowledge base for control in tidal wetlands, through systematic review of the scientific literature, interviews with experienced practitioners, and field observations at nine Pacific Northwest sites. The review framework incorporated practical considerations and key environmental conditions: elevation related to hydrologic regime, salinity, shade, and nutrient availability. The results support implementation of multiple methods for a minimum of five years, on the largest possible area, ideally the watershed scale. Applicable methods include control in advance of restoration, topographic modification such as scrape-downs and mounds; establishing strong native competitors; and periodic, targeted control. Formal field experiments are needed to evaluate factors that influence control. Developing science-based, effective, practicable approaches to control reed canarygrass should improve restoration outcomes in natural areas.

intertidal, invasive, Phalaris arundinacea, reed c↗

Cascaded Control for Building HVAC Systems in Practice

Actuator hunting is a widespread and often neglected problem in the HVAC field. Hunting is typically characterized by sustained or intermittent oscillations, and can result in decreased efficiency, increased actuator wear, and poor setpoint tracking. Cascaded control loops have been shown to effectively linearize system dynamics and reduce the prevalence of hunting. This paper details the implementation of cascaded control architectures for Air Handling Unit chilled water valves at three university campus buildings. A framework for implementation the control in existing Building Automation software is developed that requires only a single line of additional code. Results gathered for more than a year show that cascaded control not only eliminates hunting in control loops with documented hunting issues, but provides better tracking and more consistent performance during all seasons. A discussion of efficiency losses due to hunting behavior is presented and illustrated with comparative data. Furthermore, an analysis of cost savings from implementing cascaded chilled water valve control is presented. Field tests show 2.2–4.4% energy savings, with additional potential savings from reduced operational costs (i.e., maintenance and controller retuning).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Advanced Smart Ventilation Controls for Residential Applications

This study examined the use of zoned ventilation systems using a coupled CONTAM/EnergyPlus model for new California dwellings. Several smart control strategies were developed with a target of halving ventilation-related energy use, largely through reducing dwelling ventilation rates based on zone occupancy. The controls were evaluated based on the annual energy consumption relative to continuously operating non-zoned, code-compliant mechanical ventilation systems. The systems were also evaluated from an indoor air quality perspective using the equivalency approach, where the annual personal concentration of a contaminant for a control strategy is compared to the personal concentration that would have occurred using a continuously operating, non-zoned system. Individual occupant personal concentrations were calculated for the following contaminants of concern: moisture, CO2, particles, and a generic contaminant. Zonal controls that saved energy by reducing outside airflow achieved typical reductions in ventilation-related energy of 10% to 30%, compared to the 7% savings from the unzoned control. However, this was at the expense of increased personal concentrations for some contaminants in most cases. In addition, care is required in the design and evaluation of zonal controls, because control strategies may reduce exposure to some contaminants, while increasing exposure to others.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solid State Transformer Controls for Mitigation of E3a High-Altitude Electromagnetic Pulse Insults

This paper explores the use of a solid state transformer (SST) to mitigate the 𝐸 3𝐴 component of a high-altitude electromagnetic pulse (HEMP) insult using external energy storage optimal control techniques. In lieu of conventional passive blocking devices or feedback-controlled energy storage devices, a novel implementation of Hamiltonian error tracking is utilized to develop a feedback control law for the variable converter ratio in an SST. The findings of the simulations performed in this paper suggest that additional energy storage is not necessary to protect an individual load from a HEMP insult. The simulations performed examine the response of a single-phase SST connected to a single voltage source on a long transmission line on the one side and a single linear resistor on the other. The control law is specifically developed for the late-time, low-frequency portion of a HEMP insult, namely the 𝐸 3𝐴 components. The Hamiltonian error-based converter ratio control law is compared with nonlinear optimal feedforward controls to show that the HSSPFC is an external energy storage optimal controller.

HEMP mitigation↗

Strategies for Controlling the Spatial Orientation of Single Molecules Tethered on DNA Origami Templates Physisorbed on Glass Substrates: Intercalation and Stretching

Nanoarchitectural control of matter is crucial for next-generation technologies. DNA origami templates are harnessed to accurately position single molecules; however, direct single molecule evidence is lacking regarding how well DNA origami can control the orientation of such molecules in three-dimensional space, as well as the factors affecting control. Here, we present two strategies for controlling the polar (θ) and in-plane azimuthal (Φ) angular orientations of cyanine Cy5 single molecules tethered on rationally-designed DNA origami templates that are physically adsorbed (physisorbed) on glass substrates. By using dipolar imaging to evaluate Cy5's orientation and super-resolution microscopy, the absolute spatial orientation of Cy5 is calculated relative to the DNA template. The sequence-dependent partial intercalation of Cy5 is discovered and supported theoretically using density functional theory and molecular dynamics simulations, and it is harnessed as our first strategy to achieve θ control for a full revolution with dispersion as small as ±4.5°. In our second strategy, Φ control is achieved by mechanically stretching the Cy5 from its two tethers, being the dispersion ±10.3° for full stretching. These results can in principle be applied to any single molecule, expanding in this way the capabilities of DNA as a functional templating material for single-molecule orientation control. The experimental and modeling insights provided herein will help engineer similar self-assembling molecular systems based on polymers, such as RNA and proteins.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Assimilating partial observation to enhance feedback control of stochastic dynamical systems

Here, in this paper, we present a novel methodology to tackle feedback optimal control problems in scenarios where the exact state of the controlled process is unknown. It integrates data assimilation techniques and optimal control solvers to manage partial observation of the state process, a common occurrence in practical scenarios. Traditional stochastic optimal control methods assume full state observation, which is often not feasible in real-world fluid dynamics control problems. Our approach underscores the significance of utilizing observational data to inform control policy design. Specifically, we introduce a kernel learning backward stochastic differential equation (SDE) filter to enhance data assimilation efficiency and propose a sample-wise stochastic optimization method within the stochastic maximum principle framework. We demonstrate the efficacy and accuracy of our method in the control of advection-diffusion-reaction flow problem and the Dubins airplane maneuvering problem with model uncertainty.

data driven↗

Comparison of wind-farm control strategies under realistic offshore wind conditions: wake quantities of interest

Wind-farm control strategies aim to increase the efficiency, and therefore lower the levelized cost of energy, of wind farms. This is done by using turbine settings such as the yaw angle, blade pitch angles, or generator torque to manipulate the wake that negatively affects downstream turbines in the farm. Two inherently different wind-farm control methods have been identified in the literature: wake steering (WS) and active wake mixing (AWM). As one of two companion papers focused on understanding practical aspects of these two wind-farm control strategies using large-eddy simulation (LES), we below analyze the wake quantities of interest for a single wind turbine performing WS and AWM, while the companion article (Frederik et al., 2025) focuses on turbine quantities of interest including power and structural loads for the same computational setup and also includes two-turbine arrays with full and partial wake overlap. The simulations, which are based in the LES solver AMR-Wind, are tailored to have inflow conditions representative of measurements from a site off the East Coast of the US, including with strong veer and low turbulence. The turbine, which is modeled in OpenFAST and coupled to the LES, is the IEA 15 MW, an open-source offshore design. After presenting an overview of the wake recovery for the different wake-control cases, the analysis probes the fluid-dynamic causes for the different performance of the arrays reported in the companion article by examining control volumes around the wakes and the budget of the mean-flow kinetic energy (MKE) within these volumes. In the high veer environment considered, the MKE recovery is dominated by mean convection, and this is shown to especially benefit the WS strategy when a neighboring turbine is directly downstream: there is ≈65 % more available power for a downstream turbine than in the baseline case, and this power is gained primarily through mean convection on the left-tip and top-tip faces of the control volume. However, the case with imperfect knowledge of the exact wind direction favors the pulse-type AWM strategy, largely because of ≈9 % increased turbulent entrainment from aloft versus the baseline that could be related to an apparent resistance to skewing in the pulsed wake. The general reduced effectiveness of helix-type and other individual-pitch-based AWM strategies for inflow with high veer and low turbulence as reported in the companion paper is due, in part, to low magnitudes of phase-averaged turbulent entrainment. Two main findings of this study are thus that veer has a significant impact on the effectiveness of different wake-control strategies and that pulse-type AWM may be a useful strategy when the objective is power maximization in realistic, offshore flow environments with imperfect knowledge of the exact wake overlap position on the downstream turbine.

17 WIND ENERGY↗

Extension and Validation of NEMA-Style Dual-Ring Controller in SUMO

Until recently, SUMO users could not model the behavior of a ring-and-barrier traffic signal via existing signal types, which left North American SUMO users without the direct ability to capture traffic dynamics of their local networks. This work presents the methods, implementation overview, and validation of a 'dual-ring' NEMA style traffic controller which has recently been added to the main SUMO code base. A brief explanation of the 'dual-ring' implementation is also provided as context for those new to this type of traffic controller. The foundation for this work was presented at the SUMO User Conference 2021 by researchers at the US Department of Energy's National Renewable Energy Laboratory, but was not integrated into SUMO code base at the time. Following the initial inclusion of the controller to SUMO, the authors began validation of the SUMO controller against an Econolite software-in-the-loop (SIL) traffic signal controller configured with actual setup parameters from controllers in a real-world three-intersection corridor in Tuscaloosa, Alabama, USA. This paper documents the process of adding new features to the controller code as well as validating their implementation through simulation-based and automated grey-box testing is presented in this paper. Key features such as fully-actuated operation, various timing offset plans, proper next-phase fit algorithms and more, have been added and validated against this SIL system. Though not an exhaustive demonstration of features, this work is intended make more users aware of this extension of SUMO capabilities.

MATHEMATICS AND COMPUTING↗

Finite Energy and Bounded Attacks on Control System Sensor Signals

Control system networks are increasingly being connected to enterprise level networks. These connections leave critical industrial controls systems vulnerable to cyber-attacks. Most of the effort in protecting these cyber-physical systems (CPS) has been in securing the networks using information security techniques and protection and reliability concerns at the control system level against random hardware and software failures. However, besides these failures the inability of information security techniques to protect against all intrusions means that the control system must be resilient to various signal attacks for which new analysis and detection methods need to be developed. In this paper, sensor signal attacks are analyzed for observer-based controlled systems. The threat surface for sensor signal attacks is subdivided into denial of service, finite energy, and bounded attacks. In particular, the error signals between states of attack free systems and systems subject to these attacks are quantified. Optimal sensor and actuator signal attacks for the finite and infinite horizon linear quadratic (LQ) control in terms of maximizing the corresponding cost functions are computed. The closed-loop system under optimal signal attacks are provided. Illustrative numerical examples are provided together with an application to a power network with distributed LQ controllers.

Cyber-physical↗

Safer Batteries via Active Fault Tolerant Control

Safety remains a critical technological barrier for Lithium-ion batteries. Besides safer battery materials, intelligent battery management can be the key to safer batteries. Motivated by this scenario, we propose an active fault tolerant control scheme which can potentially improve battery safety. Essentially, we focus on battery internal thermal faults which may lead to thermal runaway, and design a control scheme to alleviate such fault effect at an early stage. The control scheme consists of a fault tolerant control algorithm coupled with a fault and state co-estimator. A multi-objective optimal control technique has been used to design the control algorithm whereas an unknown state-input co-estimation approach is used for the fault and state estimator. Finally, simulation studies illustrate the effectiveness of the proposed control scheme.

25 ENERGY STORAGE↗

An Update to the NREL Baseline Wind Turbine Controller: Preprint

The NREL 5MW wind turbine model is well established as an industry standard and is often used as a comparison model, or a model on which to build upon. Though effective, the legacy controller for the NREL 5MW wind turbine is built on a simple algorithm that is not up to date with many industry standards. Additionally, as the research community has advanced into more fast-paced development cycles, as systems engineering tools such as WISDEM \cite{WISDEM} are employed, and as a greater focus on controls co-design practices is encouraged, a demand for a generic wind turbine controller has arisen. This work presents updates for the NREL 5MW baseline controller to a more modern control architecture, and establishes a generic tuning framework that can be easily adapted to various wind turbines. Based on initial results, the updated generic controller eases the automatic tuning process, while maintaining or improving upon the performance of the legacy NREL 5MW controller.

17 WIND ENERGY↗

Data-Driven Linear Parameter-Varying Modeling and Control of Flexible Loads for Grid Services: Preprint

Flexible loads have great potential to improve the power grid's flexibility and stability. To effectively control large ensembles of heterogeneous loads, reliable models thereof are required. The paper presents a data-driven modeling and control approach to manage flexible loads for providing grid services. We leverage a linear parameter-varying autoregressive moving average (LPV-ARMA) model to describe the aggregate load response, where the parameters in the model are used to capture external environment impacts (e.g., weather). A gain-scheduling feedback controller is then developed to adapt to environmental variations. This data-driven approach can be easily applied to different types of loads in various environmental conditions. In addition to the ensemble controller, distributed load controllers are designed to deliver grid services, while maintaining the quality of service of inherent load tasks. We demonstrate the work on the IEEE 37-node distribution system for real-time power regulation services through control of thermostatically controlled loads.

control↗

Grid Voltage Control Analysis for Heavy-Duty Electric Vehicle Charging Stations: Preprint

This paper presents an analysis of voltage control strategies for heavy duty electric vehicle (EV) charging stations. The performance of three voltage control approaches including power factor control, preset volt-var curve control, and customized volt-var curve control, have been investigated and evaluated for three different sizes of charging stations, including single-port small charging station, three-port middle size charging station, and 6-port travel center. The charging stations have been placed on various locations of four different types of distribution systems, to obtain a comprehensive performance analysis of the three voltage control approaches under different scenarios. To quantitively compare the performance of the three voltage control approaches, a series of metrics have been designed to quantify the performance and contribute to the comprehensive analysis summary.

47 OTHER INSTRUMENTATION↗

Pressure feedback control of electro-hydraulic actuators using fixed displacement hydraulic machines

This paper presents the development of a control strategy for Electro-Hydraulic Actuator (EHA) systems based on fixed displacement hydraulic machines. Although some previous studies on EHAs show benefits in terms of energy efficiency and regeneration capability compared to conventional hydraulic systems, few studies focus on the dynamic performance of EHAs. Unlike traditional valve-controlled systems, an EHA based on a fixed displacement pump typically relies on variation of the electric motor shaft speed to control the actuator velocity. This study shows that pressure feedback can be used to control the speed of the electric machine, thus achieving the required actuator/machine dynamic response. A simulation model is developed by including the EM, the hydraulic system, and the actuation system, which can give a realistic prediction of the EHA performance for a typical duty cycle. An open-circuit EHA previously proposed by the authors is used to validate the control strategy, and the simulation results show superior dynamic performance, exhibiting a reduction in response time and oscillatory behavior, compared to a feedforward EHA controller. Following the method presented in this study, it is possible to design a controller with a pressure feedback strategy for EHA systems with different size and actuation requirements

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Lyapunov-Based Generalized Dc-Side Controller Design for PV-Connected Systems: Preprint

The objective of this paper is to realize a universal dc-side controller for photovoltaic (PV) systems where the control is agnostic to the downstream converter configuration. To achieve this, the downstream power converter and its controls are manipulated into an effective power control loop that is then cast into a generalized multi-loop design framework. On the dc side, a nonlinear small-signal model of the PV input is realized exclusively in terms of PV datasheet parameters (i.e., open-circuit voltage, short-circuit current, and maximum power point). Finally, a linear controller is used to modulate the dc-side PV system with the generic downstream power controller. A Lyapunov candidate is proposed to analyze the stability of the interconnected system and provide a streamlined approach for the controller design. The proposed design is validated on a 1-kVA experimental setup that interfaces a PV module to the grid.

dc-dc control↗

Operation and Process Control Development for a Pilot-Scale Leaching and Solvent Extraction Circuit Recovering Rare Earth Elements From Coal-Based Sources

The US Department of Energy in 2010 has identified several rare earth elements as critical materials to enable clean technologies. As part of ongoing research in REEs (rare earth elements) recovery from coal sources, the University of Kentucky has designed, developed and is demonstrating a ¼ ton/hour pilot-scale processing plant to produce high-grade REEs from coal sources. Due to the need to control critical variables (e.g. pH, tank level, etc.), process control is required. To ensure adequate process control, a study was conducted on leaching and solvent extraction control to evaluate the potential of achieving low-cost REE recovery in addition to developing a process control PLC system. The overall operational design and utilization of Six Sigma methodologies is discussed. Further, the application of the controls design, both procedural and electronic for the control of process variables such as pH is discussed. Variations in output parameters were quantified as a function of time. Data trends show that the mean process variable was maintained within prescribed limits. Future work for the utilization of data analysis and integration for data-based decision-making will be discussed.

coal, rare earth elements, pilot plant, automation↗

Reduced order methods for the improvement of control-oriented modelling of nuclear power plants - 185

In the development of the control system of a nuclear power plant, it is of primary importance to rely on simulation tools for its realization, testing and validation. These tools should provide an accurate description of the controlled response of the entire power plant in different scenarios. The classic control-oriented modelling based on 0D/1D approach is well suited for control purposes since it provides fast-running simulations and it is easy to linearize, but it may not be sufficient to deeply investigate the complexity of some systems, in particular when/where spatial phenomena have a remarkable impact on dynamics. Reduced Order Methods (ROMs) can offer the proper trade-off between computational cost and solution accuracy, combining the high-detail modelling (e.g., 3D modelling) usually adopted for design purposes with the requirements demanded for a control-oriented tool, firstly the computational efficiency. In this work, ROMs are used to improve a control-oriented plant simulator of a Lead-cooled Fast Reactor (LFR). In particular, the attention is focused on the reactor core neutronics, and on the thermal-hydraulics of the reactor pool as well. A test case regarding the design of a Kalman Filter is set up showing promising results for the application of ROM in the control context. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Operational performance risk assessment in support of a supervisory control system - 251

A supervisory control system is being developed for multiunit advanced small modular reactors to minimize human interventions during normal and abnormal operations. In the supervisory control system, control action decisions are made based on a probabilistic risk assessment that employs event trees and fault trees. Although traditional probabilistic risk assessment tools are implemented, their scope is extended to normal operations, and the application is reversed to assess the success of non-safety related systems and to enable continued operation of the plant. This extended probabilistic risk assessment approach is called operational performance risk assessment (OPRA). OPRA helps to identify available paths, combine control actions for maintaining plant conditions within operational limits, and to quantify the likelihood of success of these operational trajectories to optimize the selection of alternative actions without activating reactor protection system. In this paper, a case study of OPRA in a supervisory control system is demonstrated for the Advanced Liquid Metal Reactor (ALMR) Power Reactor Inherently Safe Module (PRISM) design, specifically the power conversion system. The scenario investigated involved a condition in which the feedwater control valve that was observed to be drifting to the closed position. Alternative plant configurations that would allow the plant to continue to operate at full or reduced power were identified using OPRA. Dynamic analyses were performed with a thermal-hydraulic model of the ALMR PRISM system using Modelica to evaluate the magnitude of safety margins. Successful recovery paths for the selected scenario were identified and quantified using the supervisory control system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗