Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computing, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Star-galaxy classification in the Dark Energy Survey Y1 dataset

Here, we perform a comparison of different approaches to star-galaxy classification using the broad-band photometric data from Year 1 of the Dark Energy Survey. We explore and compare different techniques to address this problem: morphological versus using additional flux information, differences between machine-learning, cut based and template fitting including Hierarchical Bayesian methods and catalogue-based versus image-based analyses. This is done by performing a wide range of tests with and without external ‘truth’ information, which can be ported to other similar datasets. We make a broad evaluation of the performance of the classifiers in two science cases with DES data that are most affected by this systematic effect: large-scale structure and Milky Way studies. In general, even though the default morphological classifiers used for DES Y1 cosmology studies are sufficient to maintain a low level of systematic contamination from stellar mis-classification, contamination can be reduced to the O (1%) level by using multi-epoch and infrared information from external datasets. For Milky Way studies the stellar sample can be augmented by ~20% for a given flux limit. Reference catalogues used in this work are available at http://des.ncsa.illinois.edu/releases/y1a1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nondestructive measurement of the grid ratio using a single image

The antiscatter grid is an essential part of modern radiographic systems. Since the introduction of the antiscatter grid, however, there have been few methods proposed for acceptance testing and verification of manufacturer-supplied grid specifications. The grid ratio (r) is an important parameter describing the antiscatter grid because it affects many other grid quality metrics, such as the contrast improvement ratio (K), primary transmission (T{sub p}), and scatter transmission (T{sub s}). Also, the grid ratio in large part determines the primary clinical use of the grid. To this end, the authors present a technique for the nondestructive measurement of the grid ratio of antiscatter grids. They derived an equation that can be used to calculate the grid ratio from a single off-focus flat field image by exploiting the relationship between grid cutoff and off-focus distance. The calculation can be performed by hand or with included analysis software. They calculated the grid ratios of several different grids throughout the institution, and afterward they destructively measured the grid ratio of a nominal r8 grid previously evaluated with the method. They also studied the sensitivity of the method to technical factors and choice of parameters. With one exception, the results for the grids found in the institution were in agreement with the manufacturer's specifications and international standards. The nondestructive evaluation of the r8 grid indicated a ratio of 7.3, while the destructive measurement indicated a ratio of 7.53{+-}0.28. Repeated evaluations of the same grid yielded consistent results. The technique provides the medical physicist with a new tool for quantitative evaluation of the grid ratio, an important grid performance criterion. The method is robust and repeatable when appropriate choices of technical factors and other parameters are made.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-113: The Influence of Optimizing Pediatric CT Simulator Protocols On the Treatment Dose Calculation in Radiotherapy

Purpose: To investigate the possibility of applying optimized scanning protocols for pediatric CT simulation by quantifying the dosimetric inaccuracy introduced by using a fixed HU to density conversion. Methods: The images of a CIRS electron density reference phantom (Model 062) were acquired by a Siemens CT simulator (Sensation Open) using the following settings of tube voltage and beam current: 120 kV/190mA (the reference protocol used to calibrate CT for our treatment planning system (TPS)); Fixed 190mA combined with all available kV: 80, 100, and 140; fixed 120 kV and various current from 37 to 444 mA (scanner extremes) with interval of 30 mA. To avoid the HU uncertainty of point sampling in the various inserts of known electron densities, the mean CT numbers of the central cylindrical volume were calculated using DICOMan software. The doses per 100 MU to the reference point (SAD=100cm, Depth=10cm, Field=10X10cm, 6MV photon beam) in a virtual cubic phantom (30X30X30cm) were calculated using Eclipse TPS (calculation model: AcurosXB-11031) by assigning the CT numbers to HU of typical materials acquired by various protocols. Results: For the inserts of densities less than muscle, CT number fluctuations of all protocols were within the tolerance of 10 HU as accepted by AAPM-TG66. For more condensed materials, fixed kV yielded stable HU with any mA combination where largest disparities were found in 1750mg/cc insert: HU{sub reference}=1801(106.6cGy), HU{sub minimum}=1799 (106.6cGy, error{sub dose}=0.00%), HU{sub maximum}=1815 (106.8cGy, error{sub dose}=0.19%). Yet greater disagreements were observed with increasing density when kV was modified: HU{sub minimum}=1646 (104.5cGy, error{sub dose}=- 1.97%), HU{sub maximum}=2487 (116.4cGy, error{sub dose}=9.19%) in 1750mg/cc insert. Conclusion: Without affecting treatment dose calculation, personalized mA optimization of CT simulator can be conducted by fixing kV for a better cost-effectiveness of imaging dose and quality especially for children. Unless recalibrated, kV should be constant for all anatomical sites if diagnostic CT scanner is used as a simulator. This work was partially supported by Capital Medical Development Scientific Research Fund of China.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Poster — Thur Eve — 07: Simultaneous reconstruction of both true and scattered coincidences using a Generalized Scatter reconstruction algorithm in PET

Introduction: Scattered coincidences in PET are generally taken as noise, which reduces image contrast and compromises quantification. We have developed a method, with promising results, to reconstruct activity distribution from scattered PET events instead of simply correcting for them. The implementation of this method on clinical PET scanners is however limited by the currently available detector energy resolution. With low energy resolution we lose the ability to distinguish scattered coincidences from true events based on the measured photon energy. In addition the two circular arcs used to confine the source position for a scattered event cannot be accurately defined. Method: This paper presents a modification to this approach which accounts for limited energy resolution. A measured event is split into a true and a scattered component each with different probabilities based on the position of the pair of photon energies in the energy spectrum. For the scattered component, we model the photon energy with a Gaussian distribution and the upper and lower energy limits can be estimated and used to define inner and outer circular arcs to confine the source position. The true and scattered components for each measured event were reconstructed using our Generalized Scatter reconstruction algorithm. Results and Conclusion: The results show that the contrast and noise properties were improved by 6–9% and 2–4% respectively. This demonstrates that the performance of the algorithm is less sensitive to the energy resolution and that incorporating scattered photons into reconstruction brings more benefits than simply rejecting them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-545: MLC Distance Travelled as a Predictor for Motor Failure

Purpose: To study the frequency of Multi-Leaf Collimator (MLC) leaf failures, investigate methods to predict them and reduce linac downtime. Methods: A Varian HD120 MLC was used in our study. The hyperterminal MLC errors logged from 06/2012 to 12/2014 were collected. Along with the hyperterminal errors, the MLC motor changes and all other MLC interventions by the linear accelerator engineer were recorded. The MLC dynalog files were also recorded on a daily basis for each treatment and during linac QA. The dynalog files were analyzed to calculate root mean square errors (RMS) and cumulative MLC travel distance per motor. An in-house MatLab code was used to analyze all dynalog files, record RMS errors and calculate the distance each MLC traveled per day. Results: A total of 269 interventions were recorded over a period of 18 months. Of these, 146 included MLC motor leaf change, 39 T-nut replacements, and 84 MLC cleaning sessions. Leaves close to the middle of each side required the most maintenance. In the A bank, leaves A27 to A40 recorded 73% of all interventions, while the same leaves in the B bank counted for 52% of the interventions. On average, leaves in the middle of the bank had their motors changed approximately every 1500m of travel. Finally, it was found that the number of RMS errors increased prior to an MLC motor change. Conclusion: An MLC dynalog file analysis software was developed that can be used to log daily MLC usage. Our eighteen-month data analysis showed that there is a correlation between the distance an MLC travels, the RMS and the life of the MLC motor. We plan to use this tool to predict MLC motor failures and with proper and timely intervention, reduce the downtime of the linac during clinical hours.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-624: Portal Dosimetry Commissioning of Multiple (6) Varian TrueBeam Linacs Equipped with PortalVision DMI MV Imager

Purpose: To show that a single model for Portal Domisetry (PD) can be established for beam-matched TrueBeam™ linacs that are equipped with the DMI imager (43×43cm effective area). Methods: Our department acquired 6 new TrueBeam™s, 4 “Slim” and 2 “Edge” models. The Slims were equipped with 6 and 10MV photons, and the Edges with 6MV. MLCs differed between the Slims and Edges (Millennium 120 vs HD-MLC respectively). PD model was created from data acquired using a single linac (Slim). This includes maximum field size profile, as well as output factors and acquired measured fluence using the DMI imager. All identical linacs were beam-matched, profiles were within 1% at maximum field size at a variety of depths. The profile correction file was generated from 40×40 profile acquired at 5cm depth, 95cm SSD, and was adjusted for deviation at the field edges and corners. The PD model and profile correction was applied to all six TrueBeam™s and imagers. A variety of jaw only and sliding window (SW) MLC test fields, as well as TG-119 and clinical SW and VMAT plans were run on each linac to validate the model. Results: For 6X and 10X, field by field comparison using 3mm/3% absolute gamma criteria passed 90% or better for all cases. This was also true for composite comparisons of TG-199 and clinical plans, matching our current department criteria. Conclusion: Using a single model per photon energy for PD for the TrueBeam™ equipped with a DMI imager can produce clinically acceptable results across multiple identical and matched linacs. It is also possible to use the same PD model despite different MLCs. This can save time during commissioning and software updates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fully integrated fused quartz acoustic horns for structural health monitoring

Non-destructive acoustic structural sensing is an imperative technology, applicable to many different fields such as aerospace and civil engineering. To maintain a high sensitivity or to mitigate acoustic loss, it is important to increase the signal-to-noise ratio by improving coupling efficiency from acoustic sources to the object under test, such as an acoustic waveguide. Here, a fully integrated fused quartz horn design is combined with a fused quartz acoustic waveguide. The resulting system is intended to demonstrate a high accuracy low cost alternative to current sensing systems and the present article report on the viability of using a merged acoustic horn and waveguide.

Electronic noise↗

Hardware and software for ground tests of onboard charged particle spectrometers

The article presents a hardware and software complex for ground tests of onboard charged particle spectrometers that are designed at the National Research Nuclear University MEPhI for monitoring of nuclear-physical factors of space weather and can be installed in a wide class of satellites. The structural scheme and operating principles of component parts are discussed. The main algorithm and software features are presented. The technique of ground spectrometer tests and calibrations in various measurement modes at atmospheric cosmic particle flows, both in autonomous laboratories and in interface tests as part of a satellite, is also described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New estimates of extensive-air-shower energies on the basis of signals in scintillation detectors

New formulas for estimating the energy of inclined extensive air showers (EASs) on the basis of signals in detectors by means of an original method and detailed tables of signals induced in scintillation detectors by photons, electrons, positrons, and muons and calculated with the aid of the GEANT4 code package were proposed in terms of the QGSJETII-04, EPOS LHC, and GHEISHA models. The parameters appearing in the proposed formulas were calculated by employing the CORSIKA code package. It is shown that, for showers of zenith angles in the range of 20◦–45◦, the standard constant-intensity-cut method, which is used to interpret data from the Yakutsk EAS array, overestimates the shower energy by a factor of 1.2 to 1.5. It is proposed to employ the calculated VEM (Vertical Equivalent Muon) signal units of 10.8 and 11.4 MeV for, respectively, ground-based and underground scintillation detectors and to take into account the dependence of signals on the azimuthal angle of the detector position and fluctuations in the development of showers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass Spectrometer Transient Analysis

This software implements a complete preprocessing pipeline for transient mass spectrometry (MS) data collected during TAP (Temporal Analysis of Products) experiments. It is designed to extract chemically meaningful fluxes from overlapping ion signals by applying a calibrated defragmentation matrix and solving the resulting linear system using non-negative least squares (NNLS) regression. The core script, preprocess_mass_spec.py, performs the following operations: Gain correction: Applies amplifier gain scalars derived from inert-packed calibration pulses to normalize signal intensities across AMUs and acquisition settings. Background subtraction: Removes experiment baselines using user-defined time windows, ensuring compatibility with slow-diffusing species and preventing negative values that would interfere with NNLS. Options to subtract before and after defragmentation. Defragmentation: Constructs a fragmentation matrix A from zeroth moments of calibration pulses (equal molar gas:inert mixtures) and solves Ax=b at each time point, where b is the raw MS signal and x is the estimated species flux. The matrix is normalized to inert signals and accounts for instrument-specific fragmentation behavior. Pulse-mode handling: Supports both averaged and individual pulse modes, enabling statistical treatment of fluxes and calculation of standard deviations. Integration and output: Computes zeroth moments (integrated fluxes) and exports time-resolved and integrated data in CSV format, suitable for downstream kinetic modeling. The software is validated using both virtual TAP simulations (VTAP) and experimental data from propane dehydrogenation (PDH) on CrOx/Al2O3 catalysts. It preserves temporal resolution by applying NNLS point-by-point across the pulse duration (typically 6,000+ time slices per pulse), leveraging the linear superposition principle to reconstruct full flux profiles. The defragmented outputs are compatible with kinetic extraction methods such as the G and Y procedures, which are used to derive rate–concentration relationships from TAP data. The details of these validations are discussed in detail in the supporting manuscript and supporting information. Example data and output files are also included. The methodology is robust to experimental noise and drift, with calibration protocols that account for pulse size effects, MS aging, and inert gas normalization. The software is modular, reproducible, and tailored for high-throughput TAP-MS workflows in catalysis research.

Kristy, Stephen [Idaho National Laboratory (INL), ↗

Laboratory Directed Research and Development FY2010 Annual Report

A premier applied-science laboratory, Lawrence Livermore National Laboratory (LLNL) has at its core a primary national security mission - to ensure the safety, security, and reliability of the nation's nuclear weapons stockpile without nuclear testing, and to prevent and counter the spread and use of weapons of mass destruction: nuclear, chemical, and biological. The Laboratory uses the scientific and engineering expertise and facilities developed for its primary mission to pursue advanced technologies to meet other important national security needs - homeland defense, military operations, and missile defense, for example - that evolve in response to emerging threats. For broader national needs, LLNL executes programs in energy security, climate change and long-term energy needs, environmental assessment and management, bioscience and technology to improve human health, and for breakthroughs in fundamental science and technology. With this multidisciplinary expertise, the Laboratory serves as a science and technology resource to the U.S. government and as a partner with industry and academia. This annual report discusses the following topics: (1) Advanced Sensors and Instrumentation; (2) Biological Sciences; (3) Chemistry; (4) Earth and Space Sciences; (5) Energy Supply and Use; (6) Engineering and Manufacturing Processes; (7) Materials Science and Technology; Mathematics and Computing Science; (8) Nuclear Science and Engineering; and (9) Physics.

36 MATERIALS SCIENCE↗

Using the Sirocco File System for high-bandwidth checkpoints.

The Sirocco File System, a file system for exascale under active development, is designed to allow the storage software to maximize quality of service through increased flexibility and local decision-making. By allowing the storage system to manage a range of storage targets that have varying speeds and capacities, the system can increase the speed and surety of storage to the application. We instrument CTH to use a group of RAM-based Sirocco storage servers allocated within the job as a high-performance storage tier to accept checkpoints, allowing computation to potentially continue asynchronously of checkpoint migration to slower, more permanent storage. The result is a 10-60x speedup in constructing and moving checkpoint data from the compute nodes. This demonstration of early Sirocco functionality shows a significant benefit for a real I/O workload, checkpointing, in a real application, CTH. By running Sirocco storage servers within a job as RAM-only stores, CTH was able to store checkpoints 10-60x faster than storing to PanFS, allowing the job to continue computing sooner. While this prototype did not include automatic data migration, the checkpoint was available to be pushed or pulled to disk-based storage as needed after the compute nodes continued computing. Future developments include the ability to dynamically spawn Sirocco nodes to absorb checkpoints, expanding this mechanism to other fast tiers of storage like flash memory, and sharing of dynamic Sirocco nodes between multiple jobs as needed.

99 GENERAL AND MISCELLANEOUS↗

Nevada National Security Site: Site-Directed Research and Development (Fiscal Year 2011 Annual Report)

This fiscal year 2011 annual report of the Site-Directed Research and Development program, the 10th anniversary edition, recognizes a full decade of innovative R&D accomplishments in support of the Nevada National Security Site (NNSS). Last year the NNSS itself was renamed to reflect a diversifying mission, and our R&D program has contributed significantly to shape emerging missions that will continue to evolve. New initiatives in stockpile stewardship science, nonproliferation, and treaty verification and monitoring have had substantial successes in FY 2011, and many more accomplishments are expected. SDRD is the cornerstone on which many of these initiatives rest. Historically supporting our main focus areas, SDRD is also building a solid foundation for new, and non-traditional, emerging national security missions. The program continues its charter to advance science and technology for a broad base of agencies including the U.S. Department of Energy (DOE), U.S. Department of Defense (DoD), U.S. Department of Homeland Security (DHS), and many others.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

IER-539 CED-1: Preliminary Design of a New Horizontal Split Table

This report presents the preliminary design (CED-1) of IER-539, focused on a new Horizontal Split Table (HST) critical assembly machine. The Department of Energy (DOE) National Nuclear Criticality Safety Program (NCSP) funds critical experiment R&D and its Mission and Vision document identifies a long-standing technical gap of a general purpose HST. HSTs have historically been used for experiments that are impractical to assemble on a vertical lift machine (VLM), usually due to their large physical size or weight. While many HSTs were historically employed in the US (including at LLNL), there are currently no surviving HSTs in the US. While there are two critical experiments facilities remaining in the US, the National Critical Experiments Research Center (NCERC) operated by LANL and the Critical Experiments Facility (CX) operated by SNL, these facilities are not equipped with a general purpose HST. There are a number of experiment designs that require an HST, including needs for Defense Programs and Nuclear Energy. Lack of an HST constraints the national ability to perform large and heavy experiments. Large footprints are needed to successfully create mockup experiments for advanced reactors (mock-up cold critical reactor cores, which is a urgent need for new reactor designs using novel materials and longer cycle lengths), to create solution experiments in lattices, or to test nuclear data of heavy metals. A new HST is a vital piece of criticality experiment infrastructure that would allow for the conduct of integral critical experiments to address needs in the nuclear criticality safety, nuclear data, and other DOE stakeholder communities.

42 ENGINEERING↗

BatAnalysis - A Comprehensive Python Pipeline for Swift BAT Survey Analysis

The Swift Burst Alert Telescope (BAT) is a coded-aperture gamma-ray instrument with a large field of view that primarily operates in survey mode when it is not triggering on transient events. The survey data consist of 80- channel detector plane histograms that accumulate photon counts over periods of at least 5 minutes. These histograms are processed on the ground and are used to produce the survey data set between 14 and 195 keV. Survey data comprise >90% of all BAT data by volume and allow for the tracking of long-term light curves and spectral properties of cataloged and uncataloged hard X-ray sources. Until now, the survey data set has not been used to its full potential due to the complexity associated with its analysis and the lack of easily usable pipelines. Here, we introduce the BatAnalysis Python package, a wrapper for HEASoftpy, which provides a modern, opensource pipeline to process and analyze BAT survey data. BatAnalysis allows members of the community to use BAT survey data in more advanced analyses of astrophysical sources, including pulsars, pulsar wind nebula, active galactic nuclei, and other known/unknown transient events that may be detected in the hard X-ray band. We outline the steps taken by the Python code and exemplify its usefulness and accuracy by analyzing survey data of the Crab Nebula, NGC 2992, and a previously uncataloged MAXI transient. The BatAnalysis package allows for ~18 yr of BAT survey data to be used in a systematic way to study a large variety of astrophysical sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Perils of AI-Assisted Time Conversion Critical Errors in J2000 Time to UNIX/UTC Conversions Using AI Assistants (Technical Memorandum)

This memo addresses a critical issue encountered when using AI assistants for time system conversions, specifically converting data tagged with J2000 seconds through UNIX time to UTC. Initial AI responses to this common conversion task were fundamentally incorrect, with errors exceeding 37 seconds - enough to cause significant issues in many applications. This document demonstrates the problem, quantifies the error, and provides best practices for using AI tools safely in technical work. Both Claude 4.5 Sonnet and ChatGPT GPT-5.5 Thinking gave the same answer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bridging Additive Manufacturing and Electronics Printing in the Age of AI

Printing techniques have been instrumental in developing flexible and stretchable electronics, including organic light-emitting diode displays, organic thin film transistor arrays, electronic skins, organic electrochemical transistors for biosensors and neuromorphic computing, as well as flexible solar cells with low-cost processes such as inkjet printing, ultrasonic nozzle, roll-to-roll coating. The rise of additive manufacturing provides even more opportunities to print electronics in automated and customizable ways. In this work, we will review the current technologies of printing electronics (including printed batteries, supercapacitors, fuel cells, and sensors), especially with 3D printing. In this age of ongoing AI revolution, the application of AI algorithms is discussed in terms of combining them with 3D printing and electronics printing for a future with automated optimization, sustainable design, and customizable and scalable manufacturing.

Chemistry↗