Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAMERA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Applications and Development Work for Digital Image Correlation Using High Speed Cameras

NASA, Army, and industry partners are working to advance optical measurement techniques used in highly dynamic rocket engine and missile test environments. This allows for direct component data collection during test and flight environments, significantly reduced analysis time, and associated cost savings. Digital Image Correlation (DIC) uses calibrated stereo cameras to collect three-dimensional (3-D) displacements, strains, and acceleration data by referencing a stochastic speckle pattern applied to the test object. These optical measurement techniques provide significantly improved data resulting in better performance predictions, model validation, and information about components during hot-fire tests and test flights.

Rachel Paden↗

Camera Exposure Time Determination for Artemis I Lunar Flyby

During Artemis I, a flight test was conducted using the Optical Navigation Camera to image Lunar terrain at low altitude prior to the Return Powered Flyby (RPF) burn. The vehicle descended rapidly toward the surface and transitioned over the Lunar Terminator during the time frame in which the images were to be gathered, creating challenging lighting conditions which required the development of a novel technique for exposure time determination to gather imagery of appropriate quality for post flight analysis. The resulting technique leveraged simple photometric models and simulations, as well as the spacecrafts altitude and pointing direction to determine the necessary change in exposure times over the course of the flyby, resulting in a successful flight test.

Terrain Relative Navigation↗

Camera Exposure Time Determination for Artemis I Lunar Flyby

During Artemis I, a flight test was conducted using the Optical Navigation Camera to image Lunar terrain at low altitude prior to the Return Powered Flyby (RPF) burn. The vehicle descended rapidly toward the surface and transitioned over the Lunar Terminator during the time frame in which the images were to be gathered, creating challenging lighting conditions which required the development of a novel technique for exposure time determination to gather imagery of appropriate quality for post flight analysis. The resulting technique leveraged simple photometric models and simulations, as well as the spacecrafts altitude and pointing direction to determine the necessary change in exposure times over the course of the flyby, resulting in a successful flight test.

Terrain Relative Navigation↗

Camera Exposure Time Determination for Artemis I Lunar Flyby

During Artemis I, a flight test was conducted using the Optical Navigation Camera to image Lunar terrain at low altitude prior to the Return Powered Flyby (RPF) burn. The vehicle descended rapidly toward the surface and transitioned over the Lunar Terminator during the time frame in which the images were to be gathered, creating challenging lighting conditions which required the development of a novel technique for exposure time determination to gather imagery of appropriate quality for post flight analysis. The resulting technique leveraged simple photometric models and simulations, as well as the spacecrafts altitude and pointing direction to determine the necessary change in exposure times over the course of the flyby, resulting in a successful flight test.

Terrain Relative Navigation↗

Anger Camera Firmware

The firmware is responsible for the operation of Anger Camera Electronics, calculation of position, time of flight and digital communications. It provides a first stage analysis of 48 signals from 48 analog signals that have been converted to digital values using A/D convertors.

Source record↗

Neutron camera employing row and column summations

For each photomultiplier tube in an Anger camera, an R.times.S array of preamplifiers is provided to detect electrons generated within the photomultiplier tube. The outputs of the preamplifiers are digitized to measure the magnitude of the signals from each preamplifier. For each photomultiplier tube, a corresponding summation circuitry including R row summation circuits and S column summation circuits numerically add the magnitudes of the signals from preamplifiers for each row and for each column to generate histograms. For a P.times.Q array of photomultiplier tubes, P.times.Q summation circuitries generate P.times.Q row histograms including R entries and P.times.Q column histograms including S entries. The total set of histograms include P.times.Q.times.(R+S) entries, which can be analyzed by a position calculation circuit to determine the locations of events (detection of a neutron).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibrating IR Cameras for In-Situ Temperature Measurement During the Electron Beam Melting Process using Inconel 718 and Ti-Al6-V4

The Department of Energy s (DOE) Manufacturing Demonstration Facility (MDF) at Oak Ridge National Laboratory (ORNL) provides world-leading capabilities in advanced manufacturing (AM) facilities which leverage previous, on-going government investments in materials science research and characterization. MDF contains systems for fabricating components with complex geometries using AM techniques (i.e. 3D-Printing). Various metal alloy printers, for example, use electron beam melting (EBM) systems for creating these components which are otherwise extremely difficult- if not impossible- to machine. ORNL has partnered with manufacturers on improving the final part quality of components and developing new materials for further advancing these devices. One method being used to study (AM) processes in more depth relies on the advanced imaging capabilities at ORNL. High performance mid-wave infrared (IR) cameras are used for in-situ process monitoring and temperature measurements. However, standard factory calibrations are insufficient due to very low transmissions of the leaded glass window required for X-ray absorption. Two techniques for temperature calibrations will be presented and compared. In-situ measurement of emittance will also be discussed. Ample information can be learned from in-situ IR process monitoring of the EBM process. Ultimately, these imaging systems have the potential for routine use for online quality assurance and feedback control.

Electron-Beam Melting↗

High-speed CMOS camera

A high-speed CMOS camera includes an array of pixel circuits coupled to a photodiode array, an oscillator circuit, and a pattern generator circuit. The pattern generator circuit includes a high speed shift register and a non-overlap generator. The shift register is programmable to produce a pulse train of trigger pulses that defines an interframe and a frame's shutter duration. The non-overlap generator deserializes the incoming pulse train of trigger pulses, and it produces a time-separated reset pulse based on the pulse train of trigger pulses. The shift register is configured to permit the frame durations and the interframe times to be selected arbitrarily over specified ranges in increments of a basic time unit that depends on the oscillator period.

42 ENGINEERING↗

A boron-coated CCD camera for direct detection of Ultracold Neutrons (UCN)

A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$\alpha$0$\gamma$)$^7$Li (6%) and $^{10}$B(n,$\alpha$1$\gamma$)$^7$Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolution and particle ID performance of a scientific CCD allows for observation and identification of all the byproducts $\alpha$, $^7$Li and $\gamma$ (electron recoils). A signal-to-noise improvement on the order of 10$^4$ over the indirect method has been achieved. Sub-pixel position resolution of a few microns is demonstrated. The technology can also be used to build UCN detectors with an area on the order of 1 m$^2$. The combination of micrometer scale spatial resolution, few electrons ionization thresholds and large area paves the way to new research avenues including quantum physics of UCN and high-resolution neutron imaging and spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kraken Imager and Camera Systems

Presentation describes the Kraken imager and camera systems under development for use at the Nevada National Security Site for work conducted by the National Nuclear Security Administration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Process Monitoring for Wire-Arc Additive Manufacturing Using IR Cameras

Wire-arc additive manufacturing systems use robotic MIG welders to build parts using welding wire. As a part is built the temperature rises as energy is input and the thermal mass increases. While some pre-heat is ideal for welding, improper thermal management can lead to defects and negatively affect material properties. Thermal imaging allows for non-contact thermal monitoring and can be used to track thermal gradients as well as layer temperatures before and after deposition providing a method to ensure proper thermal management. A typical IR camera setup on an mBAAM system is discussed along with methods to use thermal monitoring to improve material properties and reduce defects in the final part.

Carter, William↗

“4H” X-ray camera

A 4H X-ray camera includes a high speed, high atomic number (Z), high spatial resolution sensor for sensing X-rays having energy over 30 keV and high speed readout electronics, and the high speed, high atomic number (Z), high spatial resolution sensor is coupled to the high speed readout electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensors of world’s largest digital camera snap first 3,200-megapixel images at SLAC

Vera C. Rubin Observatory will conduct the 10-year Legacy Survey of Space and Time (LSST), which will collect 60 petabytes of data to address some of the most pressing questions about the structure and evolution of the universe and the objects in it. LSST is designed to address four science areas: Understanding Dark Matter and Dark Energy Hazardous Asteroids and the Remote Solar System The Transient Optical Sky The Formation and Structure of the Milky Way Vera C. Rubin Observatory is a federal project jointly funded by the National Science Foundation and the Department of Energy Office of Science, with early construction funding received from private donations through the LSST Corporation. The NSF-funded LSST (now Rubin Observatory) Project Office for construction was established as an operating center under the management of the Association of Universities for Research in Astronomy (AURA). The DOE-funded effort to build the Rubin Observatory LSST Camera (LSSTCam) is managed by SLAC.

79 ASTRONOMY AND ASTROPHYSICS↗

Kraken Camera System

Specification sheet for Kraken camera system being developed by NNSS Transformational Diagnostics and Imaging in Los Alamos. Will be shared internally and externally.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a Fast-Framing X-Ray Camera With Wide Dynamic Range for High-Energy Imaging

We present first characterization results, with a focus on high-flux measurements, of a fast-framing, wide-dynamic-range x-ray camera intended for high-energy imaging. The MM-PAD-2.1 uses an integrating pixel front-end with a charge removal architecture and in-pixel counter to extend the pixel well depth while maintaining low read noise across the full dynamic range. The charge-removal mechanism is dead-time-less (i.e., incoming signal continues to be integrated by the front-end while charge removal is taking place). The purpose of the highflux characterization was to determine the maximum sustained incident flux that could be measured while still exhibiting linear behavior. To this end, a 16 x 16 pixel prototype was tested at the Advanced Photon Source at Argonne National Laboratory using 10 keV photons generated by an undulator source. The intensity of the incident beam was varied over 3 orders of magnitude using a series of attenuators, and the signal integrated by the MM-PAD-2.1 prototype was compared to that measured by a He-filled ion chamber directly upstream. Initial results indicate linear performance up to ca. 10(10) ph/s in a spot spanning approximately 2 x 1.5 pixels (FWHM). The onset of transient radiation damage was observed during these measurements, characterized primarily by failure of digital readout from the detector ASIC. These effects were observed to reverse after annealing at 30 degrees C for several hours, with full recovery of the detector readout.

Shanks, Katherine S.↗

Passive millimeter wave radiometer system for calibration of infrared cameras

An apparatus for accurate measurement of surface and sub-surface temperatures of an object from a distance without contacting the object is provided. Illustrative embodiments provide for simultaneous measurement of thermal emission and emissivity in the mm-wave regime thereby enabling real-time non-contact measurement of emissivity. Corrected temperatures for the object which may be used for calibration of infrared thermographic cameras are determined from the measurement of emissivity.

Murphy, Ryan D.↗

Optical design concept of the CMB-S4 large-aperture telescopes and cameras

CMB-S4 -- the next-generation ground-based cosmic microwave background (CMB) experiment - will significantly advance the sensitivity of CMB measurements and improve our understanding of the origin and evolution of the universe. CMB-S4 will deploy large-aperture telescopes fielding hundreds of thousands of detectors at millimeter wavelengths. We present the baseline optical design concept of the large-aperture CMB-S4 telescopes, which consists of two optical configurations: (i) a new off-axis, three-mirror, free-form anastigmatic design and (ii) the existing coma-corrected crossed-Dragone design. We also present an overview of the optical configuration of the array of silicon optics cameras that will populate the focal plane with 85 diffraction-limited optics tubes covering up to 9 degrees of field of view, up to $1.1 \, \rm mm$ in wavelength. We describe the computational optimization methods that were put in place to implement the families of designs described here and give a brief update on the current status of the design effort.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗