Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

40% Whole-House Energy Savings in the Hot-Humid Climate

This guide book is a resource to help builders design and construct highly energy-efficient homes, while addressing building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the hot-humid climate can build homes that achieve whole house energy savings of 40% over the Building America benchmark (the 1993 Model Energy Code) with no added overall costs for consumers.

Best Practices guides↗

Existing Whole-House Solutions Case Study: Greenbelt Homes, Inc. Pilot Retrofit Project

In the fall of 2010, a multiyear pilot energy efficiency retrofit project was undertaken by Greenbelt Homes, Inc., (GHI) a 1,566 home cooperative of circa 1930 and 1940 homes in Greenbelt, Maryland. GHI established this pilot project to serve as a basis for decision making for the rollout of a community-wide upgrade program that will incorporate energy efficiency improvements to the building envelope and mechanical equipment. With the community upgrade fully funded by the cooperative through their membership without outside subsidies, this project presents a unique opportunity to evaluate and prioritize the wide range of benefits of high-performance retrofits based on member experience with and acceptance of the retrofit measures implemented during the pilot project. Addressing the complex interactions between benefits, trade-offs, construction methods, project management implications, realistic upfront costs, financing, and other considerations, serves as a case study for energy retrofit projects that include high-performance technologies based on the long-term value to the homeowner. The pilot project focused on identifying the added costs and energy-savings benefits of improvements. Phase 1—baseline evaluation for a representative set of 28 homes sited in seven buildings; Phase 2—installation of the building envelope improvements and continued monitoring of the energy consumption for the heating season; Phase 3—energy simulations supporting recommendations for HVAC and water heating upgrades.

Attic↗

Designing Passivating, Carrier-Selective Contacts for Photovoltaic Devices

"The first step towards building a high-efficiency solar cell is to develop an absorber with few recombination-active defects. Many photovoltaic technologies have already achieved this (monocrystalline Si, III-V materials grown on lattice-matched substrates, perovskites, polycrystalline CdTe and CIGS); those that have not (a-Si:H, organics) have been limited to low open-circuit voltage. The second step is to develop contacts that both inhibit surface recombination and allow for low-resistance collection of either only electrons or only holes. For most photovoltaic technologies, this step is both more difficult and less explored than the first, and we are unaware of a prescribed methodology for selecting materials for contacts to solar cells. We elucidate a unified, conceptual understanding of contacts within which existing contacting schemes can be interpreted and future contacting schemes can be imagined. Whereas a split of the quasi-Fermi levels of holes and electrons is required in the absorber of any solar cell to generate a voltage, carriers are eventually collected through a metallic wire in which no such quasi-Fermi-level split exists. We define a contact to be all layers between the bulk of the absorber and the recombination-active interface through which carriers are extracted. The quasi-Fermi levels must necessarily collapse at this interface, and thus the transition between maximal quasi-Fermi-level splitting (in the absorber) and no splitting occurs entirely in the contact. Depending on the solar cell architecture, the contact will usually extend from the surface of the absorber to the surface of a metal or transparent conductive oxide layer, and may include deposited or diffused doped layers (e.g., as in crystalline and thin-film Si cells) and heterostructure buffer layers (e.g., the CdS layer in a CdTe device). We further define a passivating contact as one that enables high quasi-Fermi-level splitting in the absorber (large “internal” voltage), where “high” is relative to the splitting dictated by bulk recombination. Finally, we define a carrier-selective contact as one that enables a high “external” voltage measured across the contacts, where “high” is relative to the internal voltage. With these definitions, passivating contacts are those that allow only electrons, only holes, or neither electrons or holes to transport from the absorber to any position in the contact that has recombination-active defects. An excellent example of this is a SiNx layer on a Si wafer: the layer removes dangling bonds at the wafer surface (where there are both electrons and holes) and does not allow either carrier type to travel to its outermost surface, where there are undoubtedly defects. Carrier-selective contacts are then passivating contacts that also allow for low-impedance flow of either electrons or holes (but not both) to the recombination-active, extracting interface. The most common example is a heavily doped layer that establishes an electric field at the absorber surface, which then “filters” the carriers that may pass to the contact according to the sign of their charge.

14 SOLAR ENERGY↗

A Living Laboratory for Building-Grid Integration

At PNNL we’re developing a test bed for control of how buildings interact with the grid—an important step toward helping buildings achieve their potential for reducing energy use and improving the management of the nation’s power systems. The test bed works by allowing researchers to conduct experiments on PNNL’s specially-equipped Systems Engineering Building. This unique resource will help the Department of Energy achieve its mission of reducing buildings energy use by 50 percent by 2030.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alternative Auditing Approaches

This presentation for the 2017 Energy Exchange in Tampa, Florida, offers information about advanced auditing technologies and techniques including alternative auditing approaches and considerations and caveats.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Developing High-Performance Computing Model of Vapor Transition Through Advanced Membranes for Applications in 7AC Liquid Desiccant Air Conditioners

This poster for the 2019 Advanced Manufacturing Office Peer Review covers the high-performance computing model development for applications in Liquid Desiccant Air Conditioners. Conventional compressor-based cooling has undergone incremental changes over the past 100 years. Further improvements in efficiency require evermore complex systems, especially under humid conditions. Microporous membranes offer unique opportunities for efficient humidity control in buildings using an absorbent desiccant solution, but membranes are not designed for this purpose. This project used molecular dynamic (MD) simulations to determine the effect of membrane properties on important metrics for these air-conditioning applications, focusing on the membrane properties at the membrane/liquid/air interface. Improved membranes can enable smaller, more durable, and less costly designs for these membrane air conditioning systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Topology Optimization to Achieve Energy Savings at the Urban District Level: Preprint

Advanced district thermal energy systems have the potential to achieve significant energy savings and facilitate the integration of renewable thermal resources and waste heat, contributing to reductions in carbon emissions. Such systems, also known as fifth generation district heating and cooling (5GDHC) systems, circulate water at temperatures close to ambient, and leverage electrically-driven water-source heat pumps located at connected buildings to further temper the water. However, barriers exist to the adoption of 5GDHC systems, including the factorial growth in potential network configurations as a function of the number of considered buildings. Topology optimization, which seeks to answer the questions, “Which is the best subset of buildings, if any, to connect to a district thermal energy system, and by what network should they be connected, to minimize life cycle cost?” can accelerate the adoption of 5GDHC systems. This study is part of an effort to develop a topology optimization framework for district thermal energy systems. In this study, a heuristic for one aspect of the topology optimization problem---the use of the minimal spanning tree network to connect a given set of buildings at the least life cycle cost---is validated.

28 EE - Advanced Manufacturing Office (EE-5A)↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of Passive Phoretic Decontamination by Accident Simulation in a Scaled Reactor Containment

Reactor containment performance is a critical defense-in- depth barrier for the prevention of radioactive release in the event of a nuclear accident. One of the functions of the containment is to assist in the decontamination of aerosolized radioactive particles through both 'passive' or natural processes and 'active' or mechanical processes. Current United States Nuclear Regulatory Commission (NRC) guidance (Reg. guide 1.183) allows the use of aerosol natural deposition correlations to quantify postaccident nuclear containment decontamination factors. Large Light Water Reactor (LLWR) correlations have previously been developed to quantify the contribution of natural phenomena to post-accident aerosol decontamination. Specific correlations must similarly be developed to support the safety analyses of Small Modular Reactors (SMRs). For LLWR plants, decontamination is achieved 'actively' by mechanical systems such as containment sprays and 'passively' via natural phenomena such as gravitational settling, condensation, impaction, thermophoresis, diffusiophoresis and hygroscopic effects. Integrated pressurized water reactor (iPWR) SMR designs do not have containment sprays; therefore, they rely primarily on passive natural phenomena for decontamination in the integrated reactor vessel. Analytical studies and inferences from LLWR test data suggest that the smaller containment vessel volume to surface area ratio, coupled with the thermal hydraulic properties of iPWR plants, would significantly enhance decontamination factors for these smaller designs. The research aims to quantify the amount of decontamination from natural phenomena for the range of iPWR physical and thermal hydraulic characteristics. A preliminary assessment has shown that diffusiophoresis, thermophoresis and hygroscopic effects are the major areas with a research gap for iPWR plants; hence these areas are the foci of the research. These first-of-a-kind experiments will be described and preliminary analytical results will be presented that show the expected effects of SMR-specific correlations on passive decontamination of aerosolized radionuclides.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗