Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Plasma-based beam combiner for very high fluence and energy

Extreme optical fluences, much beyond the damage threshold of conventional optics, are of interest for a range of high-energy-density physics applications. Nonlinear interactions of multiple beams in plasmas have the potential to produce optics that operate at much higher intensity and fluence than is possible in solids. In inertial confinement fusion experiments indirectly driven with lasers, many beams overlap in the plasma inside a hohlraum, and cross-beam energy transfer by Brillouin scattering has been employed to redistribute energy between laser beams within the target. Here in this paper, we show that in a hot, under-dense plasma the energy of many input beams can be combined into a single well-collimated beam. The emerging beam has an energy of 4 kJ (over 1 ns) that is more than triple that of any incident beam, and a fluence that is more than double. Because the optic produced is plasma, and is diffractive, it is inherently capable of generating higher fluences in a single beam than solid-state refractive or reflective optics.

42 ENGINEERING↗

Amplification due to two-stream instability of self-electric and magnetic fields of an ion beam propagating in background plasma

Propagation of charged particle beams in background plasma as a method of space charge neutralization has been shown to achieve a high degree of charge and current neutralization and therefore enables nearly ballistic propagation and focusing of charged particle beams. Correspondingly, the use of plasmas for propagation of charged particle beams has important applications for transport and focusing of intense particle beams in inertial fusion and high energy density laboratory plasma physics. However, the streaming of beam ions through a background plasma can lead to the development of two-stream instability between the beam ions and the plasma electrons. The beam electric and magnetic fields enhanced by the two-stream instability can lead to defocusing of the ion beam. Using particle-in-cell simulations, we study the scaling of the instability-driven self-electromagnetic fields and consequent defocusing forces with the background plasma density and beam ion mass. In conclusion, we identify plasma parameters where the defocusing forces can be reduced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

2D monochromatic x-ray imaging for beam monitoring of an x-ray free electron laser and a high-power femtosecond laser

Single-shot simultaneous beam monitoring of an x-ray free electron laser (XFEL) and a high-power femtosecond laser is demonstrated using 2D monochromatic Kα imaging. In a pump-probe experiment carried out at the Matter in Extreme Conditions end-station of the Linac Coherent Light Source, a thin solid titanium foil irradiated by a 25-TW relativistic intensity laser for fast electron isochoric heating was probed by a 7.0 keV XFEL beam for x-ray Thomson scattering measurements. Using a spherical crystal imager (SCI), the spatial overlap of the beams was examined by measuring 4.5 keV titanium Kα x rays produced by laseraccelerated fast electrons and the x-ray beam. Changes in XFEL-induced Kα emission patterns were observed down to a ~20×40 μm2 rectangular shape as the beam was focused. Laser-only and two-beam shots reveal that large spatial offsets of laser-induced Kα spots in a horizontal direction is attributed to imprecise target positioning rather than shot-to-shot laser pointing variations. As a consequence, successful beam overlapping was observed on ~58% of all two-beam shots for 10 μm thick samples. The Kα measurements also show a linear relationship between total Kα yields and integrated x-ray scattering signals. Monochromatic xray imaging with SCI could be used as an on-shot beam pointing diagnostic in XFEL-laser or multiple short-pulse laser experiments.

47 OTHER INSTRUMENTATION↗

Measurement of laser absorption in underdense plasmas using near-field imaging of the incident and transmitted beams

Measurements of laser absorption in high-temperature, underdense plasmas produced at the Omega Laser Facility are made using two near-field imaging detectors that diagnose the spatial profile and energy of the port P9 beam before and after it transmits through the plasma. The incident beam is sampled using a partial reflection from a full-aperture, (30 cm-diam) uncoated wedge pickoff located before the target chamber vacuum window and final focus lens assembly. A concave mirror reduces the reflected beam size, allowing it to be recorded directly using a charged-coupled device (CCD) camera. The P9 transmitted beam diagnostic (P9TBD) characterizes the transmitted light by terminating the expanded beam on a semi-transparent diffuser and imaging the illuminated surface using a lens and CCD camera. The P9TBD samples a numerical aperture twice as large as the input beam, allowing the energy of transmitted beams with moderate levels of beam spray to be measured accurately. Calibration shots with no plasma provide a path to infer absorption without absolute photometric calibration of either detector. Lastly, the cross-calibration between the two detectors was measured to remain stable at ±200 ppm, enabling measurements of total beam absorption below 1% with ±0.07% error.

47 OTHER INSTRUMENTATION↗

WIDE RADIO BEAMS FROM {gamma}-RAY PULSARS

We investigate the radio and {gamma}-ray beaming properties of normal and millisecond pulsars (MSPs) by selecting two samples from the known populations. The first, Sample G, contains pulsars which are detectable in blind searches of {gamma}-ray data from the Fermi Large Area Telescope. The second, Sample R, contains pulsars detectable in blind radio searches which have spin-down luminosities E>10{sup 34} erg s{sup -1}. We analyze the fraction of the {gamma}-ray-selected Sample G which have detectable radio pulses and the fraction of the radio-selected Sample R which have detectable {gamma}-ray pulses. Twenty of our 35 Sample G pulsars have already observed radio pulses. This rules out low-altitude polar-cap beaming models if, as is currently believed, {gamma}-ray beams are generated in the outer magnetosphere and are very wide. We further find that, for the highest-E pulsars, the radio and {gamma}-ray beams have comparable beaming factors, i.e., the beams cover similar regions of the sky as the star rotates. For lower-E {gamma}-ray emitting pulsars, the radio beams have about half of the {gamma}-ray sky coverage. These results suggest that, for high-E young and MSPs, the radio emission originates in wide beams from regions high in the pulsar magnetosphere, probably close to the null-charge surface and to the {gamma}-ray emitting regions. Furthermore, it suggests that for these high-E pulsars, as in the {gamma}-ray case, features in the radio profile represent caustics in the emission beam pattern.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental demonstration of accelerating a beam with a large transverse emittance ratio in the relativistic heavy ion collider for the electron-ion collider

The electron-ion collider (EIC), to be constructed at Brookhaven National Laboratory, will collide polarized high-energy electron beams with hadron beams, achieving luminosities of up to 1.0 × 10 34 cm −2 s −1 in the center-of-mass energy range of 20–140 GeV. To reach such high luminosity, the EIC will employ small, flat beams at the interaction point. According to the design of the EIC hadron storage ring (HSR), hadron beams with a large transverse emittance ratio of 11:1 will be generated at the injection energy using an electron cooling technique and then accelerated to high energies for collisions. Accelerating hadron beams with such a large emittance ratio had never been demonstrated elsewhere—until our recent beam experiment at the relativistic heavy ion collider (RHIC). In this experiment, we successfully generated a large transverse emittance ratio of 13:1 with a gold-ion beam at 31 GeV/nucleon using stochastic cooling. We then accelerated this beam, with a transverse emittance ratio of 11:1, from 31 to 100 GeV/nucleon. Thanks to RHIC’s high-performance orbit, tune, and decoupling feedback systems, the large emittance ratio was well maintained throughout the 5-min-long acceleration process. This experiment fully validated the EIC/HSR design assumptions—namely, that large-emittance-ratio hadron beams can be generated at injection energy and then accelerated to high energies for collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Parallel general purpose multiobjective optimization framework with application to electron beam dynamics

Particle accelerators are invaluable tools for research in the basic and applied sciences, such as materials science, chemistry, the biosciences, particle physics, nuclear physics and medicine. The design, commissioning, and operation of accelerator facilities is a nontrivial task, due to the large number of control parameters and the complex interplay of several conflicting design goals. The Argonne Wakefield Accelerator facility has some unique challenges resulting from its purpose to carry out advanced accelerator R&D. Individual experiments often have challenging beam requirements, and the physical configuration of the beam lines is often changed to accommodate the variety of supported experiments. The need for rapid deployment of different operational settings further complicates the optimization work that must be done for multiple constraints and challenging operational regimes. One example of this is an independently staged two-beam acceleration experiment which requires the construction of an additional beam line (this is now in progress). The high charge drive beam, well into the space charge regime, must be threaded through small aperture (17.6 mm) decelerating structures. In addition, the bunch length must be sufficiently short to maximize power generation in the decelerator. We propose to tackle this problem by means of multiobjective optimization algorithms which also facilitate a parallel deployment. In order to compute solutions in a meaningful time frame, a fast and scalable software framework is required. In this paper, we present a general-purpose framework for simulation-based multiobjective optimization methods that allows the automatic investigation of optimal sets of machine parameters. Using evolutionary algorithms as the optimizer and opal as the forward solver, validation experiments and results of multiobjective optimization problems in the domain of beam dynamics are presented. Optimized solutions for the new high charge drive beam line found by the framework were used to finish the design of a two beam acceleration experiment. The selected solution along with the associated beam parameters is presented.

43 PARTICLE ACCELERATORS↗

Experimental studies of the two-step scheme with an intense radioactive 132 Sn beam for next-generation production of very neutron-rich nuclei

The study of nuclei in the yet-unexplored, very neutron-rich, mid- to heavy-mass region of the nuclear chart, comprising perhaps half of all nuclei predicted to exist, is leading to new and/or upgraded facilities, as well as to research into the underlying production processes. In the present study, the usefulness of the two-step scheme, an alternate method to produce very neutron-rich nuclei, by a combination of an isotope-separation online (ISOL) system as a first step, and in-beam fragmentation of re-accelerated radioactive isotopes (RIs) as a second step, was investigated with a 132 Sn beam. In this work, very neutron-rich RIs around the neutron-rich neutron number N = 82 region were produced from the 278-MeV/nucleon 132 Sn beam impinging on a 5.97-mm Be target, and their production cross sections were measured. Yields were then estimated for the two-step scheme with the 132 Sn beam relative to the ones by a one-step scheme, in-flight fission of a 238 U beam, for 1-MW proton and 238 U beams at respective RI-beam facilities. This comparison suggests that the two-step scheme with the 132 Sn beam provides yields >40-times higher than those with the one-step scheme for the very neutron-rich N = 82 region. Moreover, by using various RI beams over the nuclear chart from ISOL, certain kinds of very neutron-rich RIs around the supernova r-process path can be produced with greater yields than by the one-step approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Second harmonic Bessel-Gauss beam shaping with elliptic axicon aberrations

The second harmonic (SH) of an axicon generated Bessel-Gauss beam is created through the nonlinear interaction of photons with a crystal, resulting in the energy doubling of the output photons. In this work, we show experimentally that in addition to frequency doubling, the SH of Bessel-Gauss beams under asymmetric aberrations from an elliptic axicon exhibit intriguing beam formation. Particularly, the central region of the SH beam profile is composed of two central spots of various geometries surrounded by nested ellipses; one of which is the configuration of two central gamma dots with similar radius knotted by nested ellipses for a zeroth-order Bessel-Gauss pump. These SH beams consistently maintain their spatial profile throughout propagation, reminiscing the behavior of screw dislocations in wave patterns. Our numerical simulations produce beam dynamics consistent with that of experiments and further implicate the remarkable interweaving of bright spots with dark vortices. This is especially noticeable when the beams dynamically oscillate along the optical axis, resulting in the genesis of spatially polarized beams with a knotted framework. The insights gained from our study establish a novel paradigm for exploring interactions of Bessel-like beams with vortex dynamics. This, in turn, has the potential to spark innovations in optical applications, fostering new methodologies to harness and manipulate complex light structures. Our experimental findings could spur new methods of generating logical states of light and new opportunities for material processing control. Published by the American Physical Society 2025

Wang, Tianhong (ORCID:0000000169104201)↗

Low damage etching method of low-k material with a neutral beam for interlayer dielectric of semiconductor device

To reduce the cross-talk between nanoscale devices, low-k materials such as methyl silsesquioxane (MSQ), which is damaged easily during plasma etching, are introduced as an intermetallic dielectric material in addition to the use of copper as the conducting material for the reduction of parasitic resistance and capacitance. In this study, beam techniques such as neutral/ion beams were used in the etching of MSQ and the effect of these beam techniques on the reduction of the degradation of the MSQ were investigated. When MSQ was etched using the same CF{sub 4} etch gas at the similar etch rate as that used for conventional MSQ etching using inductively coupled plasmas (ICPs), the neutral/ion beam etching showed lower F contents and lower penetration depth of F, indicating decreased degradation by fluorination of MSQ during etching using the beam techniques. Especially, the neutral beam etching technique showed the lowest F contamination and the lower penetration depth of F among the etch methods. When the dielectric constant was measured after the etching of the same depth, the MSQ etched with the neutral beam showed the lowest change of the dielectric constant, while that etched using the ICP showed the highest change of dielectric constant. The lower degradation, that is, the lower chemical modification of MSQ material with the beam technique is believed to be related to the decreased concentration of radical species in the processing chamber reacting with the MSQ surface, while the lowest degradation using the neutral beam is believed to be due to the lower reaction rate of the reactive neutral compared to reactive ions.

36 MATERIALS SCIENCE↗

Cone beam x-ray luminescence computed tomography: A feasibility study

Purpose: The appearance of x-ray luminescence computed tomography (XLCT) opens new possibilities to perform molecular imaging by x ray. In the previous XLCT system, the sample was irradiated by a sequence of narrow x-ray beams and the x-ray luminescence was measured by a highly sensitive charge coupled device (CCD) camera. This resulted in a relatively long sampling time and relatively low utilization of the x-ray beam. In this paper, a novel cone beam x-ray luminescence computed tomography strategy is proposed, which can fully utilize the x-ray dose and shorten the scanning time. The imaging model and reconstruction method are described. The validity of the imaging strategy has been studied in this paper. Methods: In the cone beam XLCT system, the cone beam x ray was adopted to illuminate the sample and a highly sensitive CCD camera was utilized to acquire luminescent photons emitted from the sample. Photons scattering in biological tissues makes it an ill-posed problem to reconstruct the 3D distribution of the x-ray luminescent sample in the cone beam XLCT. In order to overcome this issue, the authors used the diffusion approximation model to describe the photon propagation in tissues, and employed the sparse regularization method for reconstruction. An incomplete variables truncated conjugate gradient method and permissible region strategy were used for reconstruction. Meanwhile, traditional x-ray CT imaging could also be performed in this system. The x-ray attenuation effect has been considered in their imaging model, which is helpful in improving the reconstruction accuracy. Results: First, simulation experiments with cylinder phantoms were carried out to illustrate the validity of the proposed compensated method. The experimental results showed that the location error of the compensated algorithm was smaller than that of the uncompensated method. The permissible region strategy was applied and reduced the reconstruction error to less than 2 mm. The robustness and stability were then evaluated from different view numbers, different regularization parameters, different measurement noise levels, and optical parameters mismatch. The reconstruction results showed that the settings had a small effect on the reconstruction. The nonhomogeneous phantom simulation was also carried out to simulate a more complex experimental situation and evaluated their proposed method. Second, the physical cylinder phantom experiments further showed similar results in their prototype XLCT system. With the discussion of the above experiments, it was shown that the proposed method is feasible to the general case and actual experiments. Conclusions: Utilizing numerical simulation and physical experiments, the authors demonstrated the validity of the new cone beam XLCT method. Furthermore, compared with the previous narrow beam XLCT, the cone beam XLCT could more fully utilize the x-ray dose and the scanning time would be shortened greatly. The study of both simulation experiments and physical phantom experiments indicated that the proposed method was feasible to the general case and actual experiments.

60 APPLIED LIFE SCIENCES↗

Beam Dynamics Studies at the PIP-II Injector Test Facility

A series of beam dynamic studies were performed in 2020-2021 at the PIP-II Injector Test Facility (PIP2IT) that has been built to validate the concept of the front-end of the PIP-II linac being constructed at Fermilab. PIP2IT is comprised of a 30-keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT), a 2.1- MeV CW RFQ, followed by a 10-m Medium Energy Beam Transport (MEBT), 2 cryomodules accelerating the beam to 16 MeV and a High-Energy Beam Transport (HEBT) bringing the beam to a dump. This paper presents beam dynamics - related measurements performed at PIP2IT such as the Twiss parameters with Allison scanners, beam envelopes along the injector, and transverse and longitudinal rms emittance reconstruction. These measurements are compared with predictions from the beam dynamics code Tracewin.

43 PARTICLE ACCELERATORS↗

Beam Diagnostic Challenges for FACET-II

FACET-II, the Facility for Advanced Accelerator Experimental Tests II, is a new accelerator R&D test facility to be constructed at SLAC. It will provide high-energy, high-density electron and positron beams to advance the development of beam driven plasma wakefield acceleration and support a broad range of experiments. The FACET-II beams are expected to have 10 GeV energy, contain 2 nC of charge, have a transverse normalized emittance of 7 microns, be compressed to about 1 micron long and focused to about 6 micron wide at the interaction point. Additionally, the nominal peak current is 20 kA and is expected to fluctuate up to 200 kA. Most experiments desire complete knowledge of the incoming beam parameters on a pulse-to-pulse basis. However, the extreme beam densities and strong fields of the beam current will destroy any diagnostics intercepting the beam in a single shot and impose unique challenges for beam diagnostics. Moreover, non-intercepting diagnostics are desirable to provide feedback for machine setup and characterization. Finally, we need to look beyond conventional diagnostics to seek new solutions for measurements of the high charge, small beam size, short bunch length, and low emittance.

43 PARTICLE ACCELERATORS↗

A development of wide dynamic-range halo monitor for 8 GeV proton beams at FNAL

The FNAL accelerator complex has been upgrading in increasing beam intensity and beam quality. A new beam halo diagnostic device is required in the beam transport line between booster and Recycler. For this purpose, it was decided to introduce the wide dynamic range monitor technique that was developed in 2012 and has been in operation at the J-PARC beam transport line. The device is a two-dimensional beam profile monitor, and it has a dynamic range of approximately six digits of magnitude by using of Optical Transition Radiation and fluorescence screens. Eliminating harmful beam halos is the most important technique for high-intensity proton accelerators. Therefore, beam halo diagnosis is indispensable and becomes more and more important. New FNAL device has been manufactured in a collaboration between J-PARC and FNAL as a part of U.S.-Japan Science and Technology Cooperation Program in High Energy Physics. The equipment will be manufactured at J-PARC and will be shipped to FNAL in 2025.We designed the device to satisfy FNAL specifications: the beam energy, intensity, and size. Currently, most of the equipments are under construction. The large-aperture optical system has been completed and its optical characteristics are being evaluated at J-PARC. We have been also investigating measurement methods corresponding to FNAL bunch trains. This paper reports on the current status of these developments.

43 PARTICLE ACCELERATORS↗

A Wide Dynamic-Range Halo Monitor for 8 GeV Proton Beams at FNAL

Eliminating harmful beam halos is the most important technique for high-intensity proton accelerators. Therefore, beam halo diagnosis is indispensable and becomes more and more important. At J-PARC, a wide dynamic range monitor was installed in the beam transport line in 2012. The device is a two-dimensional beam profile monitor [*, **], and it has a dynamic range of approximately six digits of magnitude by using Optical Transition Radiation and fluorescence screens. The FNAL accelerator complex has been upgrading through increased beam intensity and beam quality. A new beam halo diagnostic device is required in the beam transport line between the booster and recycler. It will be manufactured in a collaboration between J-PARC and FNAL as a part of the U.S.-Japan Science and Technology Cooperation Program in High Energy Physics. We are redesigning the monitor to satisfy FNAL specifications for beam energy, intensity, and size. The equipment will be manufactured at J-PARC and then shipped to FNAL in 2024. In this report, the design of the device will be described.

43 PARTICLE ACCELERATORS↗

Generalized Courant-Snyder Theory and Kapchinskij-Vladimirskij Distribution For High-intensity Beams In A Coupled Transverse Focusing Lattice

The Courant-Snyder (CS) theory and the Kapchinskij-Vladimirskij (KV) distribution for high-intensity beams in a uncoupled focusing lattice are generalized to the case of coupled transverse dynamics. The envelope function is generalized to an envelope matrix, and the envelope equation becomes a matrix envelope equation with matrix operations that are non-commutative. In an uncoupled lattice, the KV distribution function, first analyzed in 1959, is the only known exact solution of the nonlinear Vlasov-Maxwell equations for high-intensity beams including self-fields in a self-consistent manner. The KV solution is generalized to high-intensity beams in a coupled transverse lattice using the generalized CS invariant. This solution projects to a rotating, pulsating elliptical beam in transverse configuration space. The fully self-consistent solution reduces the nonlinear Vlasov-Maxwell equations to a nonlinear matrix ordinary differential equation for the envelope matrix, which determines the geometry of the pulsating and rotating beam ellipse. These results provide us with a new theoretical tool to investigate the dynamics of high-intensity beams in a coupled transverse lattice. A strongly coupled lattice, a so-called N-rolling lattice, is studied as an example. It is found that strong coupling does not deteriorate the beam quality. Instead, the coupling induces beam rotation, and reduces beam pulsation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Energy Density Physics Experiments with Intense Heavy Ion Beams

The US heavy ion fusion science program has developed techniques for heating ion-beam-driven warm dense matter (WDM) targets. The WDM conditions are to be achieved by combined longitudinal and transverse space-charge neutralized drift compression of the ion beam to provide a hot spot on the target with a beam spot size of about 1 mm, and pulse length about 1-2 ns. As a technique for heating volumetric samples of matter to high energy density, intense beams of heavy ions are capable of delivering precise and uniform beam energy deposition dE/dx, in a relatively large sample size, and the ability to heat any solid-phase target material. Initial experiments use a 0.3 MeV K+ beam (below the Bragg peak) from the NDCX-I accelerator. Future plans include target experiments using the NDCX-II accelerator, which is designed to heat targets at the Bragg peak using a 3-6 MeV lithium ion beam. The range of the beams in solid matter targets is about 1 micron, which can be lengthened by using porous targets at reduced density. We have completed the fabrication of a new experimental target chamber facility for WDM experiments, and implemented initial target diagnostics to be used for the first target experiments in NDCX-1. The target chamber has been installed on the NDCX-I beamline. The target diagnostics include a fast multi-channel optical pyrometer, optical streak camera, VISAR, and high-speed gated cameras. Initial WDM experiments will heat targets by compressed NDCX-I beams and will explore measurement of temperature and other target parameters. Experiments are planned in areas such as dense electronegative targets, porous target homogenization and two-phase equation of state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ELECTRON BEAM SHAPING AND ITS APPLICATIONS

Transverse and longitudinal electron beam shaping is a crucial part of high-brightness electron accelerator operations. In this dissertation, we report on the corresponding beam dynamics research conducted at Fermilab Accelerator Science and Technology facility (FAST) and Argonne Wakeeld Accelerator (AWA). We demonstrate an experimental method for spatial laser and electron beam shaping using microlens arrays (MLAs) at a photoinjector facility. Such a setup was built at AWA and resulted in transverse emittance reduction by a factor of 2. We present transverse emittance partitioning methods that were recently employed at FAST facility. A strongly coupled electron beam was generated in an axial magnetic eld and accelerated in 1.3 GHz SRF cavities to 34 MeV. It was then decoupled in Round-To-Flat beam transformer and beams with emittance asymmetry ratio of 100 were generated. We introduce the new methods of measuring electron beam canonical angular momentum, beam transformer optimization and beam image analysis. We also describe a potential longitudinal space-charge amplier setup for FAST high-energy beamline. As an outcome, a broadband partially coherent radiation in the UV range could be generated.

43 PARTICLE ACCELERATORS↗