A Novel Auto-Scaling MPPT Algorithm based on Perturb and Observe Method for Photovoltaic Modules under Partial Shading Conditions

Maximum Power Point Tracking (MPPT) controller is required in a solar photovoltaic (PV) system to deliver the maximum power to load from PV module. This paper proposes a novel stepped MPPT method to realize a simple MPPT controller, which can track the real maximum power point (RMPP) even under partial shading conditions. The proposed algorithm is started by scanning the characteristic curve of the PV modules to detect the global maximum power point and then the algorithm will be switched to the conventional P&O algorithm to track the true maximum power point. The obtained simulation results, using Power electronic simulation software (PSIM), are compared with those found using the P&O method to confirm the performance of our proposed MPPT method even under non-uniform solar irradiation.

14 SOLAR ENERGY↗

Radar estimates of soil moisture over the Konza Prairie

Radar-backscatter measurements were made to estimate soil moisture. The helicopter-mounted radar was flown along selected transects that coincided with soil-moisture measurements. The radar operated at microwave frequencies of 5.3 and 9.6 GHz and at selected incidence angles between 0 and 60 degrees. Vertical polarization was used for two days and horizontal polarization was used for three days. The scattering-coefficient data from different days were grouped by frequency and antenna angles and then related to soil moisture along the flight paths using linear regression. A measure of linearity for the regression ranged between 0.9 and 0.5. The larger coefficients were for X-band measurements made at large antenna-incidence angles, and the smaller coefficients were for C-band measurements made at incidences angles near vertical.

Gogineni, S.↗

Active and passive microwave measurements of soil moisture in FIFE

During the intensive field campaigns of the First International Satellite Land Surface Climatology Project (ISLSCP) Field Experiment (FIFE) in May-October of 1987, several nearly simultaneous measurements were made with low-altitude flights of the L-band radiometer and C- and X-band scatterometers over two transects in the Konza Prairie Natural Research Area, some 8 km south of Manhattan, Kansas. These measurements showed that although the scatterometers were sensitive to soil moisture variations in most regions under the flight path, the L-band radiometer lost most of its sensitivity in regions unburned for many years. The correlation coefficient derived from the regression between the radar backscattering coefficient and the soil moisture was found to improve with the increase in antenna incidence angle. This is attributed to a steeper falloff of the backscattering coefficient as a function of local incidence at angles near nadir than at angles greater than 30 deg.

Wang, J. R.↗

Preliminary Results From the First Flight of ATIC

The Advanced Thin Ionization Calorimeter (ATIC) instrument is designed to measure the composition C and energy spectra of Z = 1 to 28 cosmic rays over the energy range approximately 10 GeV - 100 TeV. The instrument was calibrated in September 1999 at CERN using accelerated electron, proton and pion beams. ATIC was launched as a long duration balloon test flight on 12/28/00 local time from McMurdo, Antarctica. After flying successfully for about 16 days the payload was recovered in excellent condition. Absolute calibration of the detector response was made using cosmic-ray muons. The data analysis algorithm which was developed with Monte Carlo simulations and validated with the CERN beam test will be used for the flight data analysis. Preliminary results of the protons and C helium spectra will be reported in this paper.

Seo, E. S.↗

Preliminary Results From the First Flight of ATIC: Z Greater Than 8 Spectra

The Advanced Thin Ionization Calorimeter (ATIC) is designed to measure individual elemental spectra from protons to Fe for energies from 10 GeV to near 100 TeV. Preliminary results are presented for Z between 8 and 26 spectra from the maiden flight of ATIC in Antarctica that acquired 360 hours of data.

Adams, James H., Jr.↗

Preliminary Results From the First Flight of ATIC: The Silicon Matrix

The Advanced Thin Ionization Calorimeter (ATIC) uses a silicon matrix detector in conjunction with a scintillator hodoscope to determine the incident cosmic ray's charge. Cosmic rays that interact in a carbon target have their energy determined from the shower that develops within a fully active calorimeter composed of a stack of scintillating BGO crystals. The silicon matrix consists of 4480 individual silicon pads, each capable of measuring the signal from cosmic rays with atomic numbers from I to 26. Preliminary results will be presented describing the performance of the silicon matrix during the 16-day maiden flight of ATIC around Antarctica.

Adams, James H., Jr.↗

ATIC Flight Data Processing

The first flight of the Advanced Thin Ionization Calorimeter (ATIC) experiment from McMurdo, Antarctica lasted for 16 days, starting on December 28, 2000. The ATIC instrument consists of a fully active 320-crystal, 960-channel Bismuth Germanate (BGO) calorimeter, 202 scintillator strips (808 channels) in 3 hodoscopes, interleaved with graphite target layers, and a 4480-pixel silicon matrix charge detector. We have developed an object-oriented data processing package based on ROOT. In this paper, we describe the data processing scheme used in handling the accumulated 45 GB of flight data. We discuss calibration issues, particularly the time-dependence of housekeeping information.

Ahn, H. S.↗

The ATIC Experiment: Performance of the Scintillator Hodoscopes and the BGO Calorimeter

The Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment had its first flight from Mcmurdo, Antarctica 28/12/2000 to 13/01/2001, local time, recording over 360 hours of data. The design goal of ATIC was to measure the Cosmic Ray composition and energy spectra from approximately 50 GeV to near 100 TeV utilizing a Si-matrix detector, a scintillator hodoscope, carbon targets and a calorimeter consisting of a stack of BGO scintillator crystals. The design, the operations and in-flight performance of the scintillator hodoscope and the BGO calorimeter are described.

Isbert, Joachim↗

The First Flight of ATIC: Preliminary Results on Li, Be, B Nuclei

The ATIC (Advanced Thin Ionization Calorimeter) balloon experiment had its first test flight which lasted for 16 days and brought it around Antarctica. The ATIC spectrometer consists of a fully active BGO (Bismuth Germanate) calorimeter, scintillator hodoscopes and a silicon matrix. The silicon matrix consisted of 4480 pixels was used as a charge detector in the experiment. We discuss a possibility of the ATIC to measure individual energy spectra of Li, Be and B.

Zatsepin, V. I.↗

The ATIC Experiment: First Balloon Flight

The Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment had its maiden test flight from McMurdo, Antarctica 28/12/00 to 13/01/01, local time, recording over 360 hours of data. ATIC was designed to measure the composition and energy spectra of cosmic rays from approx. 10 GeV to near 100 TeV utilizing a Si matrix detector to determine charge in conjunction with a scintillator hodoscope which measures charge and trajectory. Cosmic rays that interact in a carbon target have their energy determined from the shower that develops within a fully active calorimeter composed of a stack of scintillating BGO (Bismuth Germanate) crystals. ATIC's geometry factor is about 0.25 sq. m -sr. During line-of-sight operations much of the datastream was transmitted to the ground. For most of the flight, the data was recorded on-board, yielding 45 GB of flight data for analysis. The payload construction, operations and in-flight performance are described, along with preliminary results from the on-going analysis.

Wefel, J. P.↗

High Energy Electron Detection with ATIC

The ATIC (Advanced Thin Ionization Calorimeter) balloon-borne ionization calorimeter is well suited to record and identify high energy cosmic ray electrons. The instrument was exposed to high-energy beams at CERN H2 bean-dine in September of 1999. We have simulated the performance of the instrument, and compare the simulations with actual high energy electron exposures at the CERN accelerator. Simulations and measurements do not compare exactly, in detail, but overall the simulations have predicted actual measured behavior quite well.

Chang, J.↗

The CNO Concentration in Cosmic Ray Spectrum as Measured From The Advanced Thin Ionization Calorimeter Experiment

We present preliminary results on the spectra of CNO nuclei in the cosmic radiation as measured in the first flight of the Advanced Thin Ionization Calorimeter Balloon Experiment (ATIC) which lasted for 16 days, starting in December, 2000 with a launch from McMurdo, Antarctica. ATIC is a multiple, long duration balloon flight, investigation for the study of cosmic ray spectra from below 50 GeV to near 100 TeV total energy, using a fully active Bismuth Germanate (BGO) calorimeter. It is equipped with the first large area mosaic of small fully depleted silicon detector pads capable of charge identification in cosmic rays from H to Fe. As a redundancy check for the charge identification and a coarse particle tracking system, three projective layers of x-y scintillator hodoscopes were employed, above, in the center and below a Carbon interaction "target".

Fazely, A. R.↗

Gamma Ray Large Area Space Telescope (GLAST) Balloon Flight Engineering Model: Overview

The Gamma Ray Large Area Space Telescope (GLAST) Large Area Telescope (LAT) is a pair-production high-energy (greater than 20 MeV) gamma-ray telescope being built by an international partnership of astrophysicists and particle physicists for a satellite launch in 2006, designed to study a wide variety of high-energy astrophysical phenomena. As part of the development effort, the collaboration has built a Balloon Flight Engineering Model (BFEM) for flight on a high-altitude scientific balloon. The BFEM is approximately the size of one of the 16 GLAST-LAT towers and contains all the components of the full instrument: plastic scintillator anticoincidence system (ACD), high-Z foil/Si strip pair-conversion tracker (TKR), CsI hodoscopic calorimeter (CAL), triggering and data acquisition electronics (DAQ), commanding system, power distribution, telemetry, real-time data display, and ground data processing system. The principal goal of the balloon flight was to demonstrate the performance of this instrument configuration under conditions similar to those expected in orbit. Results from a balloon flight from Palestine, Texas, on August 4, 2001, show that the BFEM successfully obtained gamma-ray data in this high-background environment.

Thompson, D. J.↗

Beam Tests of the Balloon-Borne ATIC Experiment

The Advanced Thin Ionization Calorimeter (ATIC) balloon-borne experiment is designed to perform cosmic-ray elemental spectra measurement from 50 GeV to 100 TeV for nuclei from hydrogen to iron. These measurements are expected to provide crucial hints about some of the most fundamental questions in astroparticle physics today. ATTIC'S design centers on an 18 radiation length (X(sub Omnicron)) deep bismuth germanate (BGO) calorimeter, preceded by a 0.75 lambda(sub int) graphite target. In September 1999 the ATIC detector was exposed to high-energy beams at CERN's SPS accelerator, within the framework of the development program for the Advanced Cosmic-ray Composition Experiment for the Space Station (ACCESS). In December 2000 - January 2001, ATIC flew on the first of a series of long duration balloon (LDB) flights from McMurdo Station, Antarctica. We present here results from the 1999 beam-tests, including energy resolutions for electrons and protons at several beam energies from 100 GeV to 375 GeV, as well as signal linearity and collection efficiency estimates. We show how these results compare with expectations based on simulations, and their expected impacts on mission performance.

Ganel, O.↗

Shear stress stimulates phosphorylation of eNOS at Ser(635) by a protein kinase A-dependent mechanism

Shear stress stimulates nitric oxide (NO) production by phosphorylating endothelial NO synthase (eNOS) at Ser(1179) in a phosphoinositide-3-kinase (PI3K)- and protein kinase A (PKA)-dependent manner. The eNOS has additional potential phosphorylation sites, including Ser(116), Thr(497), and Ser(635). Here, we studied these potential phosphorylation sites in response to shear, vascular endothelial growth factor (VEGF), and 8-bromocAMP (8-BRcAMP) in bovine aortic endothelial cells (BAEC). All three stimuli induced phosphorylation of eNOS at Ser(635), which was consistently slower than that at Ser(1179). Thr(497) was rapidly dephosphorylated by 8-BRcAMP but not by shear and VEGF. None of the stimuli phosphorylated Ser(116). Whereas shear-stimulated Ser(635) phosphorylation was not affected by phosphoinositide-3-kinase inhibitors wortmannin and LY-294002, it was blocked by either treating the cells with a PKA inhibitor H89 or infecting them with a recombinant adenovirus-expressing PKA inhibitor. These results suggest that shear stress stimulates eNOS by two different mechanisms: 1) PKA- and PI3K-dependent and 2) PKA-dependent but PI3K-independent pathways. Phosphorylation of Ser(635) may play an important role in chronic regulation of eNOS in response to mechanical and humoral stimuli.

Non-NASA Center↗

Hypertonicity-induced transmitter release at Drosophila neuromuscular junctions is partly mediated by integrins and cAMP/protein kinase A

The frequency of quantal transmitter release increases upon application of hypertonic solutions. This effect bypasses the Ca(2+) triggering step, but requires the presence of key molecules involved in vesicle fusion, and hence could be a useful tool for dissecting the molecular process of vesicle fusion. We have examined the hypertonicity response at neuromuscular junctions of Drosophila embryos in Ca(2+)-free saline. Relative to wild-type, the response induced by puff application of hypertonic solution was enhanced in a mutant, dunce, in which the cAMP level is elevated, or in wild-type embryos treated with forskolin, an activator of adenylyl cyclase, while protein kinase A (PKA) inhibitors decreased it. The response was also smaller in a mutant, DC0, which lacks the major subunit of PKA. Thus the cAMP/PKA cascade is involved in the hypertonicity response. Peptides containing the sequence Arg-Gly-Asp (RGD), which inhibit binding of integrins to natural ligands, reduced the response, whereas a peptide containing the non-binding sequence Arg-Gly-Glu (RGE) did not. A reduced response persisted in a mutant, myospheroid, which expresses no integrins, and the response in DC0 was unaffected by RGD peptides. These data indicate that there are at lease two components in the hypertonicity response: one that is integrin mediated and involves the cAMP/PKA cascade, and another that is not integrin mediated and does not involve the cAMP/PKA cascade.

NASA Discipline Cell Biology↗

Fertilization of sea urchin eggs and sperm motility are negatively impacted under low hypergravitational forces significant to space flight

Sperm and other flagellates swim faster in microgravity (microG) than in 1 G, raising the question of whether fertilization is altered under conditions of space travel. Such alterations have implications for reproduction of plant and animal food and for long-term space habitation by man. We previously demonstrated that microG accelerates protein phosphorylation during initiation of sperm motility but delays the sperm response to the egg chemotactic factor, speract. Thus sperm are sensitive to changes in gravitational force. New experiments using the NiZeMi centrifugal microscope examined whether low hypergravity (hyperG) causes effects opposite to microG on sperm motility, signal transduction, and fertilization. Sperm % motility and straight-line velocity were significantly inhibited by as little as 1.3 G. The phosphorylation states of FP130, an axonemal phosphoprotein, and FP160, a cAMP-dependent salt-extractable flagellar protein, both coupled to motility activation, showed a more rapid decline in hyperG. Most critically, hyperG caused an approximately 50% reduction in both the rate of sperm-egg binding and fertilization. The similar extent of inhibition of both fertilization parameters in hyperG suggests that the primary effect is on sperm rather than eggs. These results not only support our earlier microG data demonstrating that sperm are sensitive to small changes in gravitational forces but more importantly now show that this sensitivity affects the ability of sperm to fertilize eggs. Thus, more detailed studies on the impact of space flight on development should include studies of sperm function and fertilization.

NASA Discipline Developmental Biology↗

Parathyroid hormone enhances fluid shear-induced [Ca2+]i signaling in osteoblastic cells through activation of mechanosensitive and voltage-sensitive Ca2+ channels

Osteoblasts respond to both fluid shear and parathyroid hormone (PTH) with a rapid increase in intracellular calcium concentration ([Ca2+]i). Because both stimuli modulate the kinetics of the mechanosensitive cation channel (MSCC), we postulated PTH would enhance the [Ca2+]i response to fluid shear by increasing the sensitivity of MSCCs. After a 3-minute preflow at 1 dyne/cm2, MC3T3-E1 cells were subjected to various levels of shear and changes in [Ca2+]i were assessed using Fura-2. Pretreatment with 50 nM bovine PTH(1-34) [bPTH(1-34)] significantly enhanced the shear magnitude-dependent increase in [Ca2+]i. Gadolinium (Gd3+), an MSCC blocker, significantly inhibited the mean peak [Ca2+]i response to shear and shear + bPTH(1-34). Nifedipine (Nif), an L-type voltage-sensitive Ca2+ channel (VSCC) blocker, also significantly reduced the [Ca2+]i response to shear + bPTH(1-34), but not to shear alone, suggesting VSCC activation plays an interactive role in the action of these stimuli together. Activation of either the protein kinase C (PKC) or protein kinase A (PKA) pathways with specific agonists indicated that PKC activation did not alter the Ca2+ response to shear, whereas PKA activation significantly increased the [Ca2+]i response to lower magnitudes of shear. bPTH(1-34), which activates both pathways, induced the greatest [Ca2+]i response at each level of shear, suggesting an interaction of these pathways in this response. These data indicate that PTH significantly enhances the [Ca2+]i response to shear primarily via PKA modulation of the MSCC and VSCC.

Non-NASA Center↗