Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Air Conditioner Compressor Performance Model

During the past three years, the Western Electricity Coordinating Council (WECC) Load Modeling Task Force (LMTF) has led the effort to develop the new modeling approach. As part of this effort, the Bonneville Power Administration (BPA), Southern California Edison (SCE), and Electric Power Research Institute (EPRI) Solutions tested 27 residential air-conditioning units to assess their response to delayed voltage recovery transients. After completing these tests, different modeling approaches were proposed, among them a performance modeling approach that proved to be one of the three favored for its simplicity and ability to recreate different SVR events satisfactorily. Funded by the California Energy Commission (CEC) under its load modeling project, researchers at Pacific Northwest National Laboratory (PNNL) led the follow-on task to analyze the motor testing data to derive the parameters needed to develop a performance models for the single-phase air-conditioning (SPAC) unit. To derive the performance model, PNNL researchers first used the motor voltage and frequency ramping test data to obtain the real (P) and reactive (Q) power versus voltage (V) and frequency (f) curves. Then, curve fitting was used to develop the P-V, Q-V, P-f, and Q-f relationships for motor running and stalling states. The resulting performance model ignores the dynamic response of the air-conditioning motor. Because the inertia of the air-conditioning motor is very small (H<0.05), the motor reaches from one steady state to another in a few cycles. So, the performance model is a fair representation of the motor behaviors in both running and stalling states.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Compression-Ratio; Atkinson-Cycle Engine Using Low-Pressure Direct Injection and Pneumatic-Electronic Valve Actuation Enabled by Ionization Current and Foward-Backward Mass Air Flow Sensor Feedback

This report describes the work completed over a two and one half year effort sponsored by the US Department of Energy. The goal was to demonstrate the technology needed to produce a highly efficient engine enabled by several technologies which were to be developed in the course of the work. The technologies included: (1) A low-pressure direct injection system; (2) A mass air flow sensor which would measure the net airflow into the engine on a per cycle basis; (3) A feedback control system enabled by measuring ionization current signals from the spark plug gap; and (4) An infinitely variable cam actuation system based on a pneumatic-hydraulic valve actuation These developments were supplemented by the use of advanced large eddy simulations as well as evaluations of fuel air mixing using the KIVA and WAVE models. The simulations were accompanied by experimental verification when possible. In this effort a solid base has been established for continued development of the advanced engine concepts originally proposed. Due to problems with the valve actuation system a complete demonstration of the engine concept originally proposed was not possible. Some of the highlights that were accomplished during this effort are: (1) A forward-backward mass air flow sensor has been developed and a patent application for the device has been submitted. We are optimistic that this technology will have a particular application in variable valve timing direct injection systems for IC engines. (2) The biggest effort on this project has involved the development of the pneumatic-hydraulic valve actuation system. This system was originally purchased from Cargine, a Swedish supplier and is in the development stage. To date we have not been able to use the actuators to control the exhaust valves, although the actuators have been successfully employed to control the intake valves. The reason for this is the additional complication associated with variable back pressure on the exhaust valves when they are opened. As a result of this effort, we have devised a new design and have filed for a patent on a method of control which is believed to overcome this problem. The engine we have been working with originally had a single camshaft which controlled both the intake and exhaust valves. Single cycle lift and timing control was demonstrated with this system. (3) Large eddy simulations and KIVA based simulations were used in conjunction with flow visualizations in an optical engine to study fuel air mixing. During this effort we have devised a metric for quantifying fuel distribution and it is described in several of our papers. (4) A control system has been developed to enable us to test the benefits of the various technologies. This system used is based on Opal-RT hardware and is being used in a current DOE sponsored program.

33 ADVANCED PROPULSION SYSTEMS↗

Undulator Hall Air Temperature Fault Scenarios

Recent experience indicates that the LCLS undulator segments must not, at any time following tuning, be allowed to change temperature by more than about {+-}2.5 C or the magnetic center will irreversibly shift outside of acceptable tolerances. This vulnerability raises a concern that under fault conditions the ambient temperature in the Undulator Hall might go outside of the safe range and potentially could require removal and retuning of all the segments. In this note we estimate changes that can be expected in the Undulator Hall air temperature for three fault scenarios: (1) System-wide power failure; (2) Heating Ventilation and Air Conditioning (HVAC) system shutdown; and (3) HVAC system temperature regulation fault. We find that for either a system-wide power failure or an HVAC system shutdown (with the technical equipment left on), the short-term temperature changes of the air would be modest due to the ability of the walls and floor to act as a heat ballast. No action would be needed to protect the undulator system in the event of a system-wide power failure. Some action to adjust the heat balance, in the case of the HVAC power failure with the equipment left on, might be desirable but is not required. On the other hand, a temperature regulation failure of the HVAC system can quickly cause large excursions in air temperature and prompt action would be required to avoid damage to the undulator system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measuring Outdoor Air Intake Rates into Existing Building

Practical and accurate technologies are needed for continuously measuring and controlling outdoor air (OA) intake rates in commercial building heating, ventilating, and air conditioning (HVAC) systems. This project evaluated two new measurement approaches. Laboratory experiments determined that OA flow rates were measurable with errors generally less than 10 percent using electronic air velocity probes installed between OA intake louver blades or at the outlet face of louvers. High accuracy was maintained with OA flow rates as low as 15 percent of the maximum for the louvers. Thus, with this measurement approach HVAC systems do not need separate OA intakes for minimum OA supply. System calibration parameters are required for each unique combination of louver type and velocity sensor location but calibrations are not necessary for each system installation. The research also determined that the accuracy of measuring OA flow rates with velocity probes located in the duct downstream of the intake louver was not improved by installing honeycomb airflow straighteners upstream of the probes. Errors varied with type of upstream louver, were as high as 100 percent, and were often greater than 25 percent. In conclusion, use of electronic air velocity probes between the blades of OA intake louvers or at the outlet face of louvers is a highly promising means of accurately measuring rates of OA flow into HVAC systems. The use of electronic velocity probes downstream of airflow straighteners is less promising, at least with the relatively small OA HVAC inlet systems employed in this research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ANSYS Fluent CFD Modeling of Solar Air-Heater Thermoaerodynamics

Numerical modeling of thermal and aerodynamic processes taking place in a solar air heater with light-absorbing L-shaped fins is performed. The study is carried out by means of an ANSYS Fluent Solver with an integrated solar calculator for the city of Samara, Russia. The influence of the design (the step between the fins) and technological variables (the Reynolds number) on heat-exchange processes and flow aerodynamics was established during the CFD analysis. Pictorial contours are determined for the velocity distribution, pressure, and other characteristics of the airflow in the solar air-heater box. Thermoaerodynamic characteristics and effective values of technological parameters for the effective use of a solar air heater are studied. The maximum thermoaerodynamic characteristic for the solar air heater with a finned lightabsorbing surface is 1.91 for Re = 1500, and the minimum test fin pitch is 30 mm.

42 ENGINEERING↗

Quantifying energy and mass transfer in crop canopies: sensors for measurement of temperature and air velocity

Here we report on the in situ performance of inexpensive, miniature sensors that have increased our ability to measure mass and energy fluxes from plant canopies in controlled environments: 1. Surface temperature. Canopy temperature measurements indicate changes in stomatal aperture and thus latent and sensible heat fluxes. Infrared transducers from two manufacturers (Exergen Corporation, Newton, MA; and Everest Interscience, Tucson, AZ, USA) have recently become available. Transducer accuracy matched that of a more expensive hand-held infrared thermometer. 2. Air velocity varies above and within plant canopies and is an important component in mass and energy transfer models. We tested commercially-available needle, heat-transfer anemometers (1 x 50 mm cylinder) that consist of a fine-wire thermocouple and a heater inside a hypodermic needle. The needle is heated and wind speed determined from the temperature rise above ambient. These sensors are particularly useful in measuring the low wind speeds found within plant canopies. 3. Accurate measurements of air temperature adjacent to plant leaves facilitates transport phenomena modeling. We quantified the effect of radiation and air velocity on temperature rise in thermocouples from 10 to 500 micrometers. At high radiation loads and low wind speeds, temperature errors were as large as 7 degrees C above air temperature.

NASA Program CELSS↗

Regional Air Mobility: Leveraging Our National Investments to Energize the American Travel Experience

America is home to over 5,000 airports available for public use, yet only 30 of these airports serve over 70% of all travelers.01 Despite this vast network of airports, the majority are underutilized due to air transportation services that have trended towards consolidation by putting more people into fewer, larger aircraft on well-traveled routes. Also, these bigger jet-propelled aircraft can only take off from and land on longer airstrips. Regional Air Mobility (RAM) will fundamentally change how we travel by bringing the convenience, speed, and safety of air travel to all Americans, regardless of their proximity to a travel hub or urban center. We advocate RAM technology investment as complementary to and an accelerator for Advanced Air Mobility (AAM) and other initiatives that aspire to transform the airspace. Through targeted advanced technology investments, such as aircraft automation, enhanced operational models, more efficient aircraft and propulsion systems, and expanded airport renewable energy generation, many of which are already underway, RAM will increase the safety, accessibility, and affordability of regional travel while building on the extensive and underutilized federal, state, and local investment in our nation’s local airports.

Regional Air Mobility↗

From the Knowledge-based Digital Platform (KbDP) Concept for Advanced Air Mobility Research to a Preliminary Prototype

Advanced Air Mobility (AAM) encompasses a range of innovative operational and technological changes to aviation (electric aircraft, increasingly automated aircraft, increasingly automated airspace operations, etc.) that are transforming aviation’s role in everyday movement of people and goods. There are multiple associated concepts and use cases for AAM, all interrelated, including small Unmanned Aircraft System (UAS) Traffic Management (UTM), Upper-Class E Traffic Management (ETM), Extensible Traffic Management (xTM), Regional Air Mobility (RAM), and Urban Air Mobility (UAM). These AAM operations must integrate with traditional Air Traffic Management (ATM) operations, as well as non-aviation modes of transportation and logistics. National Aeronautics and Space Administration (NASA) is spearheading an innovative digital engineering approach to integrate, communicate, and facilitate the research of multi-modal transportation systems. The Knowledge-based Digital Platform (KbDP) is a concept being developed that ties the workflows of Project Managers (PM), Principal Investigators (PI), and System Engineers together across organizational boundaries. It does so through the management of an information database defined by mathematical, data science, and system engineering principles. Machine Learning (ML) algorithms play a key role in this concept by extracting meaningful knowledge from the information database, which the human user leverages to greatly improve the efficiency and effectiveness of their research. Expected benefits of this concept include improved technology transfers from research to production, improved research portfolio investments, and research outcomes that are more integrated with all aspects of the multi-modal transportation problem. The preliminary KbDP prototype has been realized using UAM as a pathfinder use case and developed by a team of system engineer, software developer, data scientist, and interns.

Systems Engineering↗

Thermal characteristics of air flow cooling in the lithium ion batteries experimental chamber

A battery pack prototype has been designed and built to evaluate various air cooling concepts for the thermal management of Li-ion batteries. The heat generation from the Li-Ion batteries was simulated with electrical heat generation devices with the same dimensions as the Li-Ion battery (200 mm x 150 mm x 12 mm). Each battery simulator generates up to 15W of heat. There are 20 temperature probes placed uniformly on the surface of the battery simulator, which can measure temperatures in the range from -40 C to +120 C. The prototype for the pack has up to 100 battery simulators and temperature probes are recorder using a PC based DAQ system. We can measure the average surface temperature of the simulator, temperature distribution on each surface and temperature distributions in the pack. The pack which holds the battery simulators is built as a crate, with adjustable gap (varies from 2mm to 5mm) between the simulators for air flow channel studies. The total system flow rate and the inlet flow temperature are controlled during the test. The cooling channel with various heat transfer enhancing devices can be installed between the simulators to investigate the cooling performance. The prototype was designed to configure the number of cooling channels from one to hundred Li-ion battery simulators. The pack is thermally isolated which prevents heat transfer from the pack to the surroundings. The flow device can provide the air flow rate in the gap of up to 5m/s velocity and air temperature in the range from -30 C to +50 C. Test results are compared with computational modeling of the test configurations. The present test set up will be used for future tests for developing and validating new cooling concepts such as surface conditions or heat pipes.

25 ENERGY STORAGE↗

Air Shipment of Spent Nuclear Fuel from Romania to Russia

Romania successfully completed the world’s first air shipment of spent nuclear fuel transported in Type B(U) casks under existing international laws and without shipment license special exceptions when the last Romanian highly enriched uranium (HEU) spent nuclear fuel was transported to the Russian Federation in June 2009. This air shipment required the design, fabrication, and licensing of special 20 foot freight containers and cask tiedown supports to transport the eighteen TUK 19 shipping casks on a Russian commercial cargo aircraft. The new equipment was certified for transport by road, rail, water, and air to provide multi modal transport capabilities for shipping research reactor spent fuel. The equipment design, safety analyses, and fabrication were performed in the Russian Federation and transport licenses were issued by both the Russian and Romanian regulatory authorities. The spent fuel was transported by truck from the VVR S research reactor to the Bucharest airport, flown by commercial cargo aircraft to the airport at Yekaterinburg, Russia, and then transported by truck to the final destination in a secure nuclear facility at Chelyabinsk, Russia. This shipment of 23.7 kg of HEU was coordinated by the Russian Research Reactor Fuel Return Program (RRRFR), as part of the U.S. Department of Energy Global Threat Reduction Initiative (GTRI), in close cooperation with the Rosatom State Atomic Energy Corporation and the International Atomic Energy Agency, and was managed in Romania by the National Commission for Nuclear Activities Control (CNCAN). This paper describes the planning, shipment preparations, equipment design, and license approvals that resulted in the safe and secure air shipment of this spent nuclear fuel.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measured Air Distribution Effectiveness for Residential Mechanical Ventilation Systems

The purpose of ventilation is dilute or remove indoor contaminants that an occupant is exposed to. In a multi-zone environment such as a house, there will be different dilution rates and different source strengths in every zone. Most US homes have central HVAC systems, which tend to mix the air thus the indoor conditions between zones. Different types of ventilation systems will provide different amounts of exposure depending on the effectiveness of their air distribution systems and the location of sources and occupants. This paper will report on field measurements using a unique multi-tracer measurement system that has the capacity to measure not only the flow of outdoor air to each zone, but zone-to-zone transport. The paper will derive seven different metrics for the evaluation of air distribution. Measured data from two homes with different levels of natural infiltration will be used to evaluate these metrics for three different ASHRAE Standard 62.2 compliant ventilation systems. Such information can be used to determine the effectiveness of different systems so that appropriate adjustments can be made in residential ventilation standards such as ASHRAE Standard 62.2.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air shower detectors in gamma-ray astronomy

Extensive air shower (EAS) arrays directly detect the particles in an EAS that reach the observation altitude. This detection technique effectively makes air shower arrays synoptic telescopes -- they are capable of simultaneously and continuously viewing the entire overhead sky. Typical air shower detectors have an effective field-of-view of 2 sr and operate nearly 100% of the time. These two characteristics make them ideal instruments for studying the highest energy gamma rays, extended sources and transient phenomena. Until recently air shower arrays have had insufficient sensitivity to detect gamma-ray sources. Over the past decade, the situation has changed markedly. Milagro, in the US, and the Tibet AS{gamma} array in Tibet, have detected very-high-energy gamma-ray emission from the Crab Nebula and the active galaxy Markarian 421 (both previously known sources). Milagro has discovered TeV diffuse emission from the Milky Way, three unidentified sources of TeV gamma rays, and several candidate sources of TeV gamma rays. Given these successes and the suite of existing and planned instruments in the GeV and TeV regime (AGILE, GLAST, HESS, VERITAS, CTA, AGIS and IceCube) there are strong reasons for pursuing a next generation of EAS detectors. In conjunction with these other instruments the next generation of EAS instruments could answer long-standing problems in astrophysics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Computational Fluid Dynamics Analyses on Very High Temperature Reactor Air Ingress

A preliminary computational fluid dynamics (CFD) analysis was performed to understand density-gradient-induced stratified flow in a Very High Temperature Reactor (VHTR) air-ingress accident. Various parameters were taken into consideration, including turbulence model, core temperature, initial air mole-fraction, and flow resistance in the core. The gas turbine modular helium reactor (GT-MHR) 600 MWt was selected as the reference reactor and it was simplified to be 2-D geometry in modeling. The core and the lower plenum were assumed to be porous bodies. Following the preliminary CFD results, the analysis of the air-ingress accident has been performed by two different codes: GAMMA code (system analysis code, Oh et al. 2006) and FLUENT CFD code (Fluent 2007). Eventually, the analysis results showed that the actual onset time of natural convection (~160 sec) would be significantly earlier than the previous predictions (~150 hours) calculated based on the molecular diffusion air-ingress mechanism. This leads to the conclusion that the consequences of this accident will be much more serious than previously expected.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India

The development of Energy Efficiency Standards and Labeling (EES&L) began in earnest in India in 2001 with the Energy Conservation Act and the establishment of the Indian Bureau of Energy Efficiency (BEE). The first main residential appliance to be targeted was refrigerators, soon to be followed by room air conditioners. Both of these appliances are of critical importance to India's residential electricity demand. About 15percent of Indian households own a refrigerator, and sales total about 4 million per year, but are growing. At the same time, the Indian refrigerator market has seen a strong trend towards larger and more consumptive frost-free units. Room air conditioners in India have traditionally been sold to commercial sector customers, but an increasing number are going to the residential sector. Room air conditioner sales growth in India peaked in the last few years at 20percent per year. In this paper, we perform an engineering-based analysis using data specific to Indian appliances. We evaluate costs and benefits to residential and commercial sector consumers from increased equipment costs and utility bill savings. The analysis finds that, while the BEE scheme presents net benefits to consumers, there remain opportunities for efficiency improvement that would optimize consumer benefits, according to Life Cycle Cost analysis. Due to the large and growing market for refrigerators and air conditioners in India, we forecast large impacts from the standards and labeling program as scheduled. By 2030, this program, if fully implemented would reduce Indian residential electricity consumption by 55 TWh. Overall savings through 2030 totals 385 TWh. Finally, while efficiency levels have been set for several years for refrigerators, labels and MEPS for these products remain voluntary. We therefore consider the negative impact of this delay of implementation to energy and financial savings achievable by 2030.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Dichlorinated Dithienylethene-Based Copolymers for Air-Stable n-Type Conductivity and Thermoelectricity

Here, two donor-acceptor polymers were obtained by coupling difluoro- and dichloro-substituted forms of the electron-deficient unit BDOPV and the relatively weak donor moiety dichlorodithienylethene (ClTVT). The conductivity and power factors of doped devices are different for the chlorinated and fluorinated BDOPV polymers. High electron conductivity of 38.3 and 16.1 S cm -1 were obtained from the chlorinated and fluorinated polymers with N-DMBI, respectively, and 12.4 and 2.4 S cm -1 were obtained from the chlorinated and fluorinated polymers with CoCp 2 , respectively, from drop-cast devices. The corresponding power factors are 22.7, 7.6, 39.5 and 8.0 μW m -1 K -2 , respectively. Doping of PClClTVT with N-DMBI results in excellent air-stability; the electron conductivity of devices with 50 mol% N-DMBI as dopant remained up to 4.9 S m -1 after 222 days in the air, the longest for an n-doped polymer stored in air, with a thermoelectric power factor of 9.3 μW m -1 K -2 . However, the conductivity of PFClTVT-based devices can hardly be measured after 103 days. These observations are consistent with morphologies determined by grazing incidence wide angle X-ray scattering (GIWAXS) and atomic force microscopy (AFM). The results demonstrate that chemical structures leading to dense and ordered packing can enhance electron conductivity and air stability of n-type donor-acceptor polymers.

30 DIRECT ENERGY CONVERSION↗

An Efficient Bifunctional Air Electrode for Reversible Protonic Ceramic Electrochemical Cells

One of the main bottlenecks that limits the performance of reversible protonic ceramic electrochemical cells (R-PCECs) is the sluggish kinetics of the oxygen reduction and evolution reactions (ORR and OER). Here, the significantly enhanced ORR and OER kinetics and stability of a conventional La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3-δ (LSCF) air electrode by an efficient catalyst coating of barium cobaltite (BCO) is reported. The polarization resistance of a BCO-coated LSCF air electrode at 600 oC is 0.16 Ω cm 2 , about 30% of that of the bare LSCF air electrode under the same conditions. Further, a R-PCEC with the BCO-coated LSCF air electrode shows exceptional performance in both fuel cell (maximum power density of 1.16 W cm -2 at 600 ºC) and electrolysis (current density of 1.80 A cm -2 at 600 ºC at 1.3 V) modes. Finally, the performance enhancement is attributed mainly to the facilitated rate of oxygen surface exchange.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ni 3 Fe-N Doped Carbon Sheets as a Bifunctional Electrocatalyst for Air Cathodes

A promising bifunctional electrocatalyst is reported for air cathodes consisting of Ni 3 Fe nanoparticles embedded in porous nitrogen–doped carbon sheets (Ni 3 Fe/N–C sheets) by a facile and effective pyrolysis–based route with sodium chloride (NaCl) crystals as a template. Here, the Ni 3 Fe/N–C sheets show excellent catalytic activity, selectivity, and durability toward both the oxygen–reduction and oxygen–evolution reactions (ORR and OER). They are shown to provide a superior, low–cost cathode for a rechargeable Zn–air battery. At a discharge–charge current density of 10 mA cm –2 , the Ni 3 Fe/N–C sheets enable a Zn–air battery to cycle steadily up to 420 h with only a small increase in the round–trip overpotential, outperforming the more costly Pt/C + IrO 2 mixture catalyst (160 h). With the simplicity and scalability of the synthetic approach and its remarkable bifunctional electrocatalytic performance, the Ni 3 Fe/N–C sheets offer a promising rechargeable air cathode operating at room temperature in an alkaline electrolyte.

36 MATERIALS SCIENCE↗

Resolving Graphite‐Electrolyte Interphase of Lithium‐Ion Batteries using Air‐Tight Ambient Mass Spectrometry

Abstract The formation of a stable solid electrolyte interphase (SEI) at graphite electrode is necessary for lithium‐ion batteries (LIB) to prevent excessive degradation of electrolytes. Until now, the exact organic composition of SEI has not been decisively determined with lithium ethylene mono‐carbonate (LEMC) being one of the debated components. An air‐tight ambient mass spectrometry (MS) platform is developed to directly characterize the air‐sensitive organic components present in SEI. Ionization occurs via a solvent‐free field‐induced process at atmospheric pressure. Our experimental data, based on tandem MS analysis, revealed LEMC to be the major organic component in SEI. This result resolves a long‐standing mystery surrounding the composition of native SEI in LIB, where no trace of the other debated compound, lithium ethylene dicarbonate, was detected. The energetics of fragmentation of LEMC and the corresponding stabilities of various ionic species detected during the air‐tight ambient MS analysis were calculated using density functional theory (DFT). Our findings confirmed favorable protonation energies and suggested the molecular structures for many of the detected species. Solvent (i. e., ethylene carbonate)‐induced stabilization effects observed during the ionization process were also confirmed by DFT. The reported study encourages the routine use of ambient mass spectrometry to characterize both anodic and cathodic electrodes of all battery types as well as to study other air‐sensitive materials in their native state.

25 ENERGY STORAGE↗