Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ADAPTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

MUSE adaptive-optics spectroscopy confirms dual active galactic nuclei and strongly lensed systems at sub-arcsec separation

The novel Gaia multi peak (GMP) technique has proven to be able to successfully select dual and lensed active galactic nuclei (AGN) candidates at sub-arcsecond separations. Both populations are important because dual AGN represent one of the central, still largely untested, predictions of ΛCDM cosmology, and compact lensed AGN allow us to probe the central regions of the lensing galaxies. In this work, we present high-spatial-resolution spectroscopy of 12 GMP-selected systems. We used the adaptive-optics assisted integral-field spectrograph MUSE at the VLT to resolve each system and investigate the nature of each component. All targets show the presence of two components confirming the GMP selection. We classify 4 targets as dual AGN, 3 as lensed quasar candidates, and 5 as a chance alignment of a star and an AGN. With separations ranging from 0.30″ to 0.86″, these dual and lensed systems are among the most compact systems discovered to date at z > 0.5. This is the largest sample of distant dual AGN with sub-arcsecond separations ever presented in a single paper.

Scialpi, M. (ORCID:0009000651004986)↗

Calibrating Microscopic Car-Following Models for Adaptive Cruise Control Vehicles: Multiobjective Approach

Adaptive cruise control (ACC) vehicles are the first step toward comprehensive vehicle automation. However, the impacts of such vehicles on the underlying traffic flow are not yet clear. Therefore, it is of interest to accurately model vehicle-level dynamics of commercially available ACC vehicles so that they may be used in further modeling efforts to quantify the impact of commercially available ACC vehicles on traffic flow. Importantly, not only model selection but also the calibration approach and error metric used for calibration are critical to accurately model ACC vehicle behavior. In this work, we explore the question of how to calibrate car following models to describe ACC vehicle dynamics. Specifically, we apply a multi-objective calibration approach to understand the tradeoff between calibrating model parameters to minimize speed error vs. spacing error. Three different car-following models are calibrated for data from six vehicles. The results are in line with recent literature and verify that targeting a low spacing error does not compromise the speed accuracy whether the opposite is not true for modeling ACC vehicle dynamics.

33 ADVANCED PROPULSION SYSTEMS↗

Polymeric electrochemical element for adaptive networks: Pulse mode

An electrochemically controlled polymeric heterojunction working as a memristor, i.e., having memory properties, was investigated in pulse mode, mimicking synaptic behavior of signal transmission in biological systems. Influence of parameters such as pulse duration, interval between pulses, and value of potential base level was analyzed. Learning capabilities were shown to be reversible and repeatable for both potentiation and inhibition of signal transmission. The adaptive behavior of the element was investigated and was shown to be more efficient than the dc mode.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive spatially resolving detector for the extreme ultraviolet with absolute measuring capability

A spatially resolving detector for the extreme ultraviolet (XUV) and soft x-ray spectral region is presented. Principle of operation is conversion of XUV radiation to visible light by a scintillator crystal. Luminescence is detected using charge coupled device camera and imaging optics. Single layer and multilayer coatings are applied to match the system to different spectral regions of interest. Field of view and spatial resolution can be adapted to the application. Calibration of the system enables to absolutely measure in-band radiation flux on the scintillator. The setup is designed for the characterization and optimization of XUV sources and XUV optical systems. Measurements, carried out to characterize the focus in a soft x-ray microscope, are presented as an application example.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An 'optimal' spawning algorithm for adaptive basis set expansion in nonadiabatic dynamics

The full multiple spawning (FMS) method has been developed to simulate quantum dynamics in the multistate electronic problem. In FMS, the nuclear wave function is represented in a basis of coupled, frozen Gaussians, and a 'spawning' procedure prescribes a means of adaptively increasing the size of this basis in order to capture population transfer between electronic states. Herein we detail a new algorithm for specifying the initial conditions of newly spawned basis functions that minimizes the number of spawned basis functions needed for convergence. 'Optimally' spawned basis functions are placed to maximize the coupling between parent and child trajectories at the point of spawning. The method is tested with a two-state, one-mode avoided crossing model and a two-state, two-mode conical intersection model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time fast inverse dose optimization for image guided adaptive radiation therapy-Enhancements to fast inverse dose optimization (FIDO)

A fast, accurate and stable optimization algorithm is very important for inverse planning of intensity-modulated radiation therapy (IMRT), and for implementing dose-adaptive radiotherapy in the future. Conventional numerical search algorithms with positive beam weight constraints generally require numerous iterations and may produce suboptimal dose results due to trapping in local minima regions of the objective function landscape. A direct solution of the inverse problem using conventional quadratic objective functions without positive beam constraints is more efficient but it will result in unrealistic negative beam weights. We review here a direct solution of the inverse problem that is efficient and does not yield unphysical negative beam weights. In fast inverse dose optimization (FIDO) method the objective function for the optimization of a large number of beamlets is reformulated such that the optimization problem is reducible to a linear set of equations. The optimal set of intensities is then found through a matrix inversion, and negative beamlet intensities are avoided without the need for externally imposed ad hoc conditions. In its original version [S. P. Goldman, J. Z. Chen, and J. J. Battista, in Proceedings of the XIVth International Conference on the Use of Computers in Radiation Therapy, 2004, pp. 112-115; S. P. Goldman, J. Z. Chen, and J. J. Battista, Med. Phys. 32, 3007 (2005)], FIDO was tested on single two-dimensional computed tomography (CT) slices with sharp KERMA beams without scatter, in order to establish a proof of concept which demonstrated that FIDO could be a viable method for the optimization of cancer treatment plans. In this paper we introduce the latest advancements in FIDO that now include not only its application to three-dimensional volumes irradiated by beams with full scatter but include as well a complete implementation of clinical dose-volume constraints including maximum and minimum dose as well as equivalent uniform dose constraints. The method has been integrated into a commercial treatment planning system (Pinnacle, Philips Medical Systems) for beta testing using clinical radiotherapy cases and standard dose constraints set by radiation oncologists. Our FIDO method consistently delivered excellent treatment plans comparable and often better than those obtained using standard optimization techniques that are considerably slower. By design, FIDO is guaranteed to find a global minimum and will achieve highly conformal and homogeneous dose distributions without the need for artificial internal contours that must be created in conventional IMRT optimization systems to help the search engines better control some beam entry directions and in this way avoid the creation of hot and cold spots. This method provides a fast, intuitive and robust technique that yields excellent results for the inverse planning of IMRT. FIDO's ability to efficiently optimize very large numbers of beamlet weights also makes it an ideal tool for the optimization of helical tomotherapy. Future gains in speed will make it possible to use FIDO for instant treatment plan reoptimization using CT images produced at the radiotherapy machine, just prior to daily treatments of the patient.

61 RADIATION PROTECTION AND DOSIMETRY↗

Performances of a bent-crystal spectrometer adapted to resonant x-ray emission measurements on gas-phase samples

We describe a bent-crystal spectrometer adapted to measure x-ray emission resulting from core-level excitation of gas-phase molecules in the 0.8-8 keV energy range. The spectrometer is based on the Johann principle, and uses a microfocused photon beam to provide high-resolution (resolving power of {approx}7500). A gas cell was designed to hold a high-pressure (300 mbar) sample of gas while maintaining a high vacuum (10{sup -9} mbar) in the chamber. The cell was designed to optimize the counting rate (2000 cts/s at the maximum of the Cl K{alpha} emission line), while minimizing self-absorption. Example of the K{alpha} emission lines of CH{sub 3}Cl molecules is presented to illustrate the capabilities of this new instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptive {delta}f Monte Carlo Method for Simulation of RF-heating and Transport in Fusion Plasmas

Essential for modeling heating and transport of fusion plasma is determining the distribution function of the plasma species. Characteristic for RF-heating is creation of particle distributions with a high energy tail. In the high energy region the deviation from a Maxwellian distribution is large while in the low energy region the distribution is close to a Maxwellian due to the velocity dependency of the collision frequency. Because of geometry and orbit topology Monte Carlo methods are frequently used. To avoid simulating the thermal part, {delta}f methods are beneficial. Here we present a new {delta}f Monte Carlo method with an adaptive scheme for reducing the total variance and sources, suitable for calculating the distribution function for RF-heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Boltzmann Solver with Adaptive Mesh in Velocity Space

We describe the implementation of direct Boltzmann solver with Adaptive Mesh in Velocity Space (AMVS) using quad/octree data structure. The benefits of the AMVS technique are demonstrated for the charged particle transport in weakly ionized plasmas where the collision integral is linear. We also describe the implementation of AMVS for the nonlinear Boltzmann collision integral. Test computations demonstrate both advantages and deficiencies of the current method for calculations of narrow-kernel distributions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical simulation of current sheet formation in a quasiseparatrix layer using adaptive mesh refinement

The formation of a thin current sheet in a magnetic quasiseparatrix layer (QSL) is investigated by means of numerical simulation using a simplified ideal, low-{beta}, MHD model. The initial configuration and driving boundary conditions are relevant to phenomena observed in the solar corona and were studied earlier by Aulanier et al. [Astron. Astrophys. 444, 961 (2005)]. In extension to that work, we use the technique of adaptive mesh refinement (AMR) to significantly enhance the local spatial resolution of the current sheet during its formation, which enables us to follow the evolution into a later stage. Our simulations are in good agreement with the results of Aulanier et al. up to the calculated time in that work. In a later phase, we observe a basically unarrested collapse of the sheet to length scales that are more than one order of magnitude smaller than those reported earlier. The current density attains correspondingly larger maximum values within the sheet. During this thinning process, which is finally limited by lack of resolution even in the AMR studies, the current sheet moves upward, following a global expansion of the magnetic structure during the quasistatic evolution. The sheet is locally one-dimensional and the plasma flow in its vicinity, when transformed into a comoving frame, qualitatively resembles a stagnation point flow. In conclusion, our simulations support the idea that extremely high current densities are generated in the vicinities of QSLs as a response to external perturbations, with no sign of saturation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linear dichroism amplification: Adapting a long-known technique for ultrasensitive femtosecond IR spectroscopy

We demonstrate strong amplification of polarization-sensitive transient IR signals using a pseudo-null crossed polarizer technique first proposed by Keston and Lospalluto [Fed. Proc. 10, 207 (1951)] and applied for nanosecond flash photolysis in the visible by Che et al. [Chem. Phys. Lett. 224, 145 (1994)]. We adapted the technique to ultrafast pulsed laser spectroscopy in the infrared using photoelastic modulators, which allow us to measure amplified linear dichroism at kilohertz repetition rates. The method was applied to a photoswitch of the N-alkylated Schiff base family in order to demonstrate its potential of strongly enhancing sensitivity and signal to noise in ultrafast transient IR experiments, to simplify spectra and to determine intramolecular transition dipole orientations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adaptive Injection-locking Oscillator Array for RF Spectrum Analysis

A highly parallel radio frequency receiver using an array of injection-locking oscillators for on-chip, rapid estimation of signal amplitudes and frequencies is considered. The oscillators are tuned to different natural frequencies, and variable gain amplifiers are used to provide negative feedback to adapt the locking band-width with the input signal to yield a combined measure of input signal amplitude and frequency detuning. To further this effort, an array of 16 two-stage differential ring oscillators and 16 Gilbert-cell mixers is designed for 40-400 MHz operation. The injection-locking oscillator array is assembled on a custom printed-circuit board. Control and calibration is achieved by on-board microcontroller.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive Smoothed Finite Elements (ASFEM) for history dependent material models

A successful simulation of a bulk forming process with finite elements can be difficult due to distortion of the finite elements. Nodal smoothed Finite Elements (NSFEM) are an interesting option for such a process since they show good distortion insensitivity and moreover have locking-free behavior and good computational efficiency. In this paper a method is proposed which takes advantage of the nodally smoothed field. This method, named adaptive smoothed finite elements (ASFEM), revises the mesh for every step of a simulation without mapping the history dependent material parameters. In this paper an updated-Lagrangian implementation is presented. Several examples are given to illustrate the method and to show its properties.

36 MATERIALS SCIENCE↗

Adaptive beam tracking and steering via electrowetting-controlled liquid prism

We report an electrowetting-controlled optofluidic system for adaptive beam tracking and agile steering. With two immiscible fluids in a transparent cell, we can actively control the contact angle along the fluid-fluid-solid tri-junction line and hence the orientation of the fluid-fluid interface via electrowetting. The naturally formed meniscus between the two liquids can function as an optical prism. We have fabricated a liquid prism module with an aperture size of 10 mm -10mm. With 1 wt.% KCl and 1 wt.% Sodium Dodecyl Sulfate added into deionized water, the orientation of the water-silicone oil interface has been modulated between -26 degrees and 26 degrees that can deflect and steer beam within the incidence angle of 0 degrees-15 degrees. The wide-range beam tracking and steering enables the liquid prism work as an electrowetting solar cell. (C) 2011 American Institute of Physics. [doi: 10.1063/1.3660578]

Cheng, JT↗

Rotational positioning system adapted to atomic force microscope for measuring anisotropic surface properties

The diverse atomic configurations induce the anisotropic surface properties. For investigating anisotropic phenomena, we developed a rotational positioning system adapted to atomic force microscope (AFM). This rotational positioning system is applied to revolve the measured sample to defined angular direction, and it composed of an inertial rotational stepper and a visual angular measurement. The inertial rotational stepper with diameter 30 mm and height 7.6 mm can be easily attached to the AFM-system built in any general optical microscope. Based on a clearance less bearing and the inertial driving method, its bidirectional angular resolution reaches 0.005 deg. per step. For realizing a close-loop controlled angular positioning function, the visual measurement method is utilized. Through the feedback control, the angular positioning error is less than 0.01 deg. For verifying the system performance, we used it to investigate the anisotropic surface properties of graphite. Through a modified cantilever tip, the atomic-scale stick-slip, and the anisotropic friction phenomena can be distinctly detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multichannel transition emissions of Dy{sup 3+} in fiber-adaptive germanium tellurite glasses

Multichannel transition visible and near-infrared (NIR) fluorescences have been captured in Dy{sup 3+}-doped fiber-adaptive Na{sub 2}O-ZnO-PbO-GeO{sub 2}-TeO{sub 2} glasses. The maximum stimulated emission cross-sections {sigma}{sub em-max} were derived to be 0.33 Multiplication-Sign 10{sup -21}, 3.66 Multiplication-Sign 10{sup -21}, and 0.67 Multiplication-Sign 10{sup -21} cm{sup 2} for conventional visible emissions assigned to {sup 4}F{sub 9/2}{yields}{sup 6}H{sub J} (J = 15/2, 13/2, and 11/2) transitions, respectively. Infrequent multi-peak NIR emissions were recorded in the spectral range of 900-1500 nm, among which the values of {sigma}{sub em-max} were solved to be 1.05 Multiplication-Sign 10{sup -22} and 1.56 Multiplication-Sign 10{sup -22} cm{sup 2} for {approx}1.02 and {approx}1.18 {mu}m emission bands. Internal quantum efficiency for the {sup 4}F{sub 9/2} level and external quantum yield for visible emissions of Dy{sup 3+} were determined to be 88.44% and 12.38%, severally. Effective multichannel radiative emissions reveal a potential in developing fiber-lighting sources, tunable lasers, and NIR optical amplifiers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Linear-scaling symmetry-adapted perturbation theory with scaled dispersion

We present a linear-scaling symmetry-adapted perturbation theory (SAPT) method that is based on an atomic orbital (AO) formulation of zeroth-order SAPT (SAPT0). The non-dispersive terms are realized with linear-scaling cost using both the continuous fast multipole method (CFMM) and the linear exchange (LinK) approach for integral contractions as well as our efficient Laplace-based coupled-perturbed self-consistent field method (DL-CPSCF) for evaluating response densities. The reformulation of the dispersion term is based on our linear-scaling AO Møller-Plesset second-order perturbation theory (AO-MP2) method, that uses our recently introduced QQR-type screening [S. A. Maurer, D. S. Lambrecht, J. Kussmann, and C. Ochsenfeld, J. Chem. Phys. 138, 014101 (2013)] for preselecting numerically significant energy contributions. Similar to scaled opposite-spin MP2, we neglect the exchange-dispersion term in SAPT and introduce a scaling factor for the dispersion term, which compensates for the error and at the same time accounts for basis set incompleteness effects and intramonomer correlation. We show in extensive benchmark calculations that the new scaled-dispersion (sd-)SAPT0 approach provides reliable results for small and large interacting systems where the results with a small 6-31G** basis are roughly comparable to supermolecular MP2 calculations in a triple-zeta basis. The performance of our method is demonstrated with timings on cellulose fragments, DNA systems, and cutouts of a protein-ligand complex with up to 1100 atoms on a single computer core.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗