Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “57”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Outcomes in patients ≥ 80 years with a diagnosis of a hepatopancreaticobiliary (HPB) malignancy

Older patients are underrepresented in oncological clinical trials. The incidence of hepatopancreaticobiliary (HPB) malignancies is higher in older patients, but data on outcomes are lacking. This study assessed patient outcomes in those < 80 and ≥ 80 years with a HPB malignancy seen at a tertiary referral centre, The Christie NHS Foundation Trust. Data on patients with a HPB malignancy were collected retrospectively between 2012 and 2017 via on-line case-note review. Survival was calculated using the Kaplan–Meier method and prognostic factors using log-rank analysis. Of 1421 patients, 10% were ≥ 80 years. Of patients < 80 and ≥ 80 years, 56% and 57% had pancreas cancer, 39% and 36% biliary tract cancer, and 5% and 7% had hepatocellular carcinoma, respectively. Amongst patients ≥ 80 years, 75% had an Eastern Cooperative Oncology Group performance status (ECOG PS) 0–2. Patients ≥ 80 years had higher rates of comorbidity; 28% received systemic anti-cancer therapy (SACT), compared with 62% of patients < 80 years. Best supportive care (BSC) was instituted in 44% of older patients, compared with 13% in those < 80 years. Of patients ≥ 80 years who received SACT, 82% received monotherapy. Median overall survival (OS) for patients receiving palliative SACT was 10.07 months (95% CI 8.89–11.08) and 10.10 months (95% CI 6.30–12.30) in patients < 80 and ≥ 80 years, respectively, p 0.41; ECOG PS (p < 0.001) was prognostic for OS in older patients but Adult Comorbidity Evaluation-27 comorbidity score (p = 0.07, when comparing groups of ACE score ≤ 1 and > 1) was not. Baseline factors were similar in both age cohorts, but more comorbidities were present in older patients. Older patients were less likely to receive SACT, but when they did, they had an equivalent benefit in OS to younger patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Energy savings potential from improved building controls for the US commercial building sector

The U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) sponsored a study to determine the potential national savings achievable in the commercial building sector through widespread deployment of best practice controls, elimination of system and component faults, and use of better sensing. Detailed characterization of potential savings was one source of input to set research, development, and deployment (RD&D) goals in the field of building sensors and controls. DOE’s building energy simulation software, EnergyPlus, was employed to estimate the potential savings from 34 measures in 9 building types and across 16 climates representing almost 57% of commercial building sector energy consumption. In addition to estimating savings from individual measures, three packages of measures were created to estimate savings from the packages. These packages represented an 1) efficient building, 2) typical building, and 3) inefficient building. To scale the results from individual measures or a package to the national scale, building weights by building type and climate locations from the Energy Information Administration’s 2012 Commercial Building Energy Consumption Survey (CBECS) were used. The results showed significant potential for energy savings across all building types and climates. The total site potential savings from individual measures by building type and climate location ranged between 0% and 25%. The total site potential savings by building type aggregated across all climates (using the CBECS building weights) for each measure varied between 0% and 16%. The total site potential savings aggregated across all building types and climates for each measure varied between 0% and 11%. Some individual measures had negative savings because correcting underlying operational problems (e.g., inadequate ventilation) resulted in increased energy consumption. When combined into packages, the overall national savings potential is estimated to be 29%; seven of the nine building types were in the range of 23 to 29% and two exceeded 40%. The total potential national site savings in for each building type ranged between 95x106 GJ (0.09 Quadrillion British thermal units [Quads]; Large Hotels) to 222x106 GJ (0.21 Quads; Large Office, Hospital Administrative areas, and College/University), resulting in total site savings of 1,393x106 GJ (1.32 Quads) when the three packages are applied to the U.S. commercial buildings stock. Using the source (or primary) energy conversion factors of 1.05 for natural gas and 3.14 for electricity resulted in an approximate potential primary energy savings of 2,912x106 GJ (2.76 Quads), which would be 15% of the sector’s 2015 use of approximately 18,991x106 GJ (18 Quads). Extrapolating the results for other building types not analyzed as part of this study, the primary energy savings could be in the range of 4,220x106 GJ to 5,275x106 GJ (4 to 5 Quads). If this savings potential is realized, it would be equivalent to not combusting 180 to 230 million tons of coal or reducing the energy impacts, at today’s energy intensities, of the per capita consumption of 12 to 15 million people in the U.S. To realize most of this potential savings, many gaps can be addressed through RD&D, as recommended in this paper.

Fernandez, Nick↗

Policy implications of allocation methods in the life cycle analysis of integrated corn and corn stover ethanol production

Here, a biorefinery may produce multiple fuels from more than one feedstock. The ability of these fuels to qualify as one of the four types of biofuels under the US Renewable Fuel Standard and to achieve a low carbon intensity score under California’s Low Carbon Fuel Standard can be strongly influenced by the approach taken to their life cycle analysis (LCA). For example, in facilities that may co-produce corn grain and corn stover ethanol, the ethanol production processes can share the combined heat and power (CHP) that is produced from the lignin and liquid residues from stover ethanol production. We examine different LCA approaches to corn grain and stover ethanol production considering different approaches to CHP treatment. In the baseline scenario, CHP meets the energy demands of stover ethanol production first, with additional heat and electricity generated sent to grain ethanol production. The resulting greenhouse gas (GHG) emissions for grain and stover ethanol are 57 and 25 g-CO 2 eq/MJ, respectively, corresponding to a 40 and 74% reduction compared to the GHG emissions of gasoline. We illustrate that emissions depend on allocation of burdens of CHP production and corn farming, along with the facility capacities. Co-product handling techniques can strongly influence LCA results and should therefore be transparently documented.

09 BIOMASS FUELS↗

Towards an Integrated Process for CO 2 Capture and Utilization: Cultivation of Scenedesmus acutus Using Gaseous CO 2 and NH 3

Integrating CO 2 scrubbing from flue gas with its utilization in algae cultivation represents a potential means of lowering the cost of CO 2 capture. Towards this goal, this study sought to assess the feasibility of using gaseous a CO 2 /NH 3 stream, derived from CO 2 capture using aqueous ammonia, as a C- and N-source for algae cultivation. Scenedesmus acutus was cultured in 800 mL photobioreactors using gaseous CO 2 /NH 3 in mole ratios varying from 7 to 18. Excellent growth of Scenedesmus acutus was observed, the average growth rate for CO 2 /NH 3 = 10 of 0.171 ± 0.015 g/L·day exceeding that obtained using 1% CO 2 /N 2 and urea as the N-source (0.099 ± 0.28 g/L·day). Under optimal growth conditions (CO 2 /NH 3 mole ratio of 10), CO 2 utilization ranged from 57% to 72%, while the NH 3 utilization was >90%. The CO 2 /NH 3 feed rate was also found to exert a significant effect on algae productivity, excessive feed rates leading to accumulation of NH 3 in the culture at concentrations that were toxic to the algae. Consequently, to avoid the toxic effects of high NH 3 concentrations (>2.0 mM), it proved necessary to balance the NH 3 supply with the algae growth rate so that excessive NH 3 accumulation was prevented. This indicates that for practical applications, a CO 2 /NH 3 feed control strategy would be required that takes into account the ammonium ion concentration in solution and the pH so as to avoid significant concentrations of free NH 3 . Furthermore, analysis of the harvested biomass revealed a high protein (≥ 47 wt%) and a low ash content (< 3.6 wt%), suggesting it would be well suited for use as animal feed or as a feedstock for the production of bioplastics.

03 NATURAL GAS↗

Application and evaluation of a pattern-based building energy model calibration method using public building datasets

Building performance simulation has been adopted to support decision making in the building life cycle. An essential issue is to ensure a building energy simulation model can capture the reality and complexity of buildings and their systems in both the static characteristics and dynamic operations. Building energy model calibration is a technique that takes various types of measured performance data (e.g., energy use) and tunes key model parameters to match the simulated results with the actual measurements. This study performed an application and evaluation of an automated pattern-based calibration method on commercial building models that were generated based on characteristics of real buildings. A public building dataset that includes high-level building attributes (e.g., building type, vintage, total floor area, number of stories, zip code) of 111 buildings in San Francisco, California, USA, was used to generate building models in EnergyPlus. Monthly level energy use calibrations were then conducted by comparing building model results against the actual buildings' monthly electricity and natural gas consumption. The results showed 57 out of 111 buildings were successfully calibrated against actual buildings, while the remaining buildings showed opportunities for future calibration improvements. Enhancements to the pattern-based model calibration method are identified to expand its use for: (1) central heating, ventilation and air conditioning (HVAC) systems with chillers, (2) space heating and hot water heating with electricity sources, (3) mixed-use building types, and (4) partially occupied buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Relation between quantitative coronary CTA and myocardial ischemia by adenosine stress myocardial CT perfusion

Background: Coronary-computed tomography angiography (CTA) has limited accuracy to predict myocardial ischemia. Besides luminal area stenosis, other coronary plaque morphology and composition parameters may help to assess ischemia. With the integration of coronary CTA and adenosine stress CT myocardial perfusion (CTP), reliable information regarding coronary anatomy and function can be derived in one procedure. This analysis aimed to investigate the association between coronary stenosis severity, plaque composition and morphology and the presence of ischemia measured with adenosine stress myocardial CTP. Methods and Results: 84 patients (age, 62 ± 10 years; 48% men) who underwent sequential coronary CTA and adenosine stress myocardial CT perfusion were analyzed. Automated quantification was performed in all coronary lesions (quantitative CTA). Downstream myocardial ischemia was assessed by visual analysis of the rest and stress CTP images and defined as a summed difference score of ≥1. One or more coronary plaques were present in 146 coronary arteries of which 31 (21%) were ischemia-related. Of the lesions with a stenosis percentage <50%, 50%-70%, and >70%, respectively, 9% (6/67), 18% (9/51), and 57% (16/28) demonstrated downstream ischemia. Furthermore, mean plaque burden, plaque volume, lesion length, maximal plaque thickness, and dense calcium volume were significantly higher in ischemia-related lesions, but only stenosis severity (%) (OR 1.06; 95% CI 1.02-1.10; P = .006) and lesion length (mm) (OR 1.26; 95% CI 1.02-1.55; P = .029) were independent correlates. Conclusions: Increasing stenosis percentage by quantitative CTA is positively correlated to myocardial ischemia measured with adenosine stress myocardial CTP. However, stenosis percentage remains a moderate determinant. Lumen area stenosis and lesion length were independently associated with ischemia, adjusted for coronary plaque volume, mean plaque burden, maximal lesion thickness, and dense calcium volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical performance of Rb-82 myocardial perfusion PET and Tc-99m-based SPECT in patients with extreme obesity

Background: We evaluated the performance of stress imaging with technetium-99m-labeled tetrofosmin single-photon emission computed tomography (SPECT) and rubidium-82 positron emission tomography (PET) in patients with extreme obesity, defined as body mass index ≥40 kg/m{sup 2}. Methods: We identified patients with extreme obesity who underwent angiography in our center and either stress SPECT or PET within the previous six months. Cohorts of patients with extreme obesity and a <5% pretest likelihood of CAD who underwent SPECT (N = 25) or PET (N = 25) were also included. Results: In total, 108 patients who underwent SPECT (N = 57) or PET (N = 51) were identified. Scan interpretation was classified as definitely normal or abnormal in 83.3% of PET and 60.5% of SPECT scans, respectively (P < .01). PET demonstrated higher diagnostic accuracy and normalcy rate. PET was found to have higher specificity for the pooled cohort. Similar findings were observed using stenosis cut-offs of ≥50% and ≥70%. Conclusions: In patients with extreme obesity, PET enabled more definitive scan interpretation with less artifact compared to SPECT. PET provided higher diagnostic accuracy and specificity in the detection of obstructive coronary artery disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of left ventricular contraction patterns using gated SPECT MPI to predict cardiac resynchronization therapy response

Background: The U-shaped left ventricular (LV) contraction pattern, identified by MRI or echocardiography, is associated with improved CRT response. Gated SPECT MPI can measure both myocardial viability and mechanical dyssynchrony in a single scan. The aim of this study is to examine the relationship of the LV contraction pattern and the response of CRT in patients with left bundle branch block (LBBB). Methods: Fifty-eight patients who met CRT guidelines and who had pre-CRT MPI were enrolled. Myocardial segments with tracer uptake < 50% of maximum were considered as scar. The LV contraction pattern was considered as U-shaped or non-U-shaped (U-shaped has a block line in the direction of contraction propagation). CRT response was defined as an increase in left ventricular ejection fraction ≥ 5% after 6-month follow-up. Results: Twenty-eight patients (48%) had a U-shaped contraction pattern and thirty patients (52%) had a non-U-shaped contraction pattern. The U-shaped group showed a significantly higher response rate than the non-U-shaped group (90% vs. 57%; P = 0.005). By univariate and multivariate logistic regression analysis, the U-shaped pattern was an independent predictor of CRT response. Conclusion: Non-invasive gated SPECT MPI can characterize LV mechanical contraction patterns. A U-shaped contraction pattern identified is associated with improved CRT response. This may prove useful for improved patient selection for CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Non-cardiac uptake of technetium-99m pyrophosphate in transthyretin cardiac amyloidosis

Background: Technetium-based bone scintigraphy is rapidly becoming the most common non-invasive imaging tool in the diagnosis of Transthyretin cardiac amyloidosis (ATTR). Skeletal muscle uptake has been described with technetium-99m-3,3-diphosphono-1,2-propanodicarboxylic acid (TcDPD), and may account for masking of bony uptake. We sought to investigate skeletal muscle uptake of technetium-99m-pyrophosphate (TcPYP) in patients with ATTR. Methods and Results: This was a retrospective analysis of 57 patients diagnosed with ATTR who underwent TcPYP scintigraphy. Cardiac uptake was assessed on whole-body planar imaging using a semiquantitative scale (grades 0 to 3) and on single-photon emission computed tomography (SPECT) with CT attenuation correction using total myocardial counts per voxel after a 3-hour incubation. Skeletal muscle (psoas and biceps), vertebral body, LV myocardium, and blood pool mean counts were calculated. In the cohort (age 78 ± 9 years, 77% male, and 30% hereditary ATTR), there was no visualized tracer uptake in skeletal muscle or soft tissue on qualitative SPECT assessment. Total and blood pool-corrected uptake in the muscle groups were significantly less than myocardium and bone (P < 0.001). Blood pool-corrected muscle uptake was not associated with semiquantitative grade 3 vs 2 uptake (psoas P = 0.66, biceps P = 0.13) or presence of hereditary ATTR (psoas P = 0.43, biceps P = 0.69). As bony uptake decreased, there was no corresponding increase in skeletal muscle uptake. Conclusions: In patients with ATTR cardiac amyloidosis, skeletal muscle uptake of TcPYP is minimal when assessed by qualitative and quantitative metrics, and is not significantly different in patients with grade 2 vs 3 semiquantitative uptake. The properties of this tracer may be different than TcDPD with respect to non-cardiac uptake.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analogies and disparities among scintigraphic bone tracers in the diagnosis of cardiac and non-cardiac ATTR amyloidosis

In this issue of JNC, BW Spery and Coll report a retrospective analysis of 57 patients with transthyretin-related amyloidosis (ATTR) in an advanced phase of the disease who underwent 99mTechnetium-pyrophosphate (99mTcPYP) scintigraphy. Although relatively small and “negative,” the study is relevant since it broadens our knowledge on the uptake of “bone tracers” in ATTR and contributes to understand the limitations of the clinical use of scintigraphy in this disease. The paper raises, directly or indirectly, at least three questions: To what extent are the different bone tracers interchangeable for the diagnosis of ATTR cardiac amyloidosis? Are bone tracers able to image non-cardiac ATTR amyloidosis? What is the explanation for the variable performance of the different bone tracers in the diagnosis of cardiac and extracardiac ATTR amyloidosis?.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative life cycle assessment of woody biomass processing: air classification, drying, and size reduction powered by bioelectricity versus grid electricity

Sulfur accumulation during biofuel production is pollutive and toxic to conversion catalysts and causes the premature breakdown of processing equipment. Air classification is an effective preprocessing technology for ash and sulfur reduction from biomass feedstocks. Here, a life cycle assessment (LCA) sought to understand the environmental impact of implementing air classification as a sulfur-mitigation technique to improve feedstock quality for pine residues using a grid electricity scenario (GES) versus a bioelectricity scenario (BES). Global warming potential (GWP) for preprocessing was simulated using inventory databases embedded in SimaPro and the Argonne National Laboratory’s GREET model, specifically focusing on comparing the GWP of a GES versus a BES. Overall, the GES had a GWP impact over seven times that of the BES (136 versus 18 kg CO 2 equivalent per tonne of usable feedstock), with steam generation during rotary drying accounting for 57% of the GES’s GWP. Air classification represents 0.4% and 1.6% of the total GWP impact for the GES and BES, respectively. Therefore, air classification can facilitate a 30% reduction in feedstock sulfur content to improve feedstock quality for biofuel conversion and lessen corrosion of equipment while contributing minimal GWP impact during preprocessing.

Air classification↗

Properties of a thick-section narrow-gap gas tungsten arc weld of cast Haynes 282

Abstract A 50.8-mm-deep gas tungsten arc weld was made with matching filler metal in cast Haynes 282 alloy. The narrow-gap joint was filled with 104 weld beads. Visual and dye-penetrant inspection of cross-weld specimens indicated that the cast base metal contained numerous casting defects. No visible indications of physical defects were found in the weld deposit. The weld heat-affected zone was characterized by microcracking and localized recrystallization. The cause of the cracking could not be determined. Hardness testing showed that a softened region in the as-welded heat-affected zone was nearly eliminated by post-weld heat treatment. Tensile testing up to 816 °C showed that cross-weld specimen strengths ranged from 57 to 79% of the cast base metal tensile strength. The stress-rupture strengths of cross-weld specimens are within 20% of base metal reference data. Failures of both tensile and stress-rupture specimens occurred in the base metal.

282↗

An innovative carbonated cementitious material and its printability and carbon mineralization capacity

The main goal of this research is to develop a carbonated cementitious material (CCMs) mix design and demonstrate its rapid stiffening for manufacturing 3D printed or precast elements for building construction (i.e., concrete with enhanced durability and CO 2 capture efficiency). The material development employs hydrated Ca(OH) 2 , and its distinct reaction with CO 2 to form CaCO 3 . Different formulations and additives including polymer materials enable the thermomechanical properties that give these CCMs 3D printability comparable with cement materials used for similar applications. Here, printable and castable CCM formulations were successfully developed and demonstrated to mineralize CO 2 to form up to 57% CaCO 3 .

36 MATERIALS SCIENCE↗

Removal of inorganic mercury by selective extraction and coprecipitation for determination of methylmercury in mercury-contaminated soils by chemical vapor generation inductively coupled plasma mass spectrometry (CVG-ICP-MS)

A procedure is developed for selective extraction of methylmercury (CH 3 Hg + ) from heavily Hg-contaminated soils and sediments for determination by chemical vapor generation inductively coupled plasma mass spectrometry (CVG-ICP-MS). Soils artificially contaminated with 40 μg g –1 inorganic mercury (Hg 2+ ) or methylmercury chloride (CH 3 HgCl) were agitated by shaking or exposing to ultrasounds in dilute hydrochloric acid (HCl) or nitric acid (HNO 3 ) solutions at room temperature. Extractions in HCl (5 or 10% v/v) resulted in substantial leaching of Hg 2+ from soils, whereas 5% (v/v) HNO 3 provided selectivity for quantitative extraction of CH 3 Hg + with minimum Hg 2+ leaching. Agitation with ultrasounds in 5% (v/v) HNO 3 for about 3 min was sufficient for extraction of all CH 3 Hg + from soils. Coprecipitations with Fe(OH) 3 , Bi(OH) 3 and HgS were investigated for removal of residual Hg 2+ in soil extracts. Hydroxide precipitations were not effective. Thiourea or l-cysteine added to soil extracts prior to hydroxide precipitation improved precipitation of Hg 2+ , but also resulted in removal of CH 3 Hg + . HgS precipitation was made with dilute ammonium sulfide solution, (NH 4 ) 2 S. Adding 30 μL of 0.35 mol L –1 (NH 4 ) 2 S to soil extracts in 5% (v/v) HNO 3 resulted in removal of all residual Hg 2+ without impacting CH 3 Hg + levels. Vapor generation was carried out by reacting Hg 2+ -free soil extracts with 1% (m/v) NaBH 4 . No significant interferences were observed from (NH 4 ) 2 S on the vapor generation from CH 3 Hg + . The slopes of the calibration curves for CH 3 HgCl standard solutions in 5% (v/v) HNO 3 with and without (NH 4 ) 2 S were similar. Limits of detection (LOD, 3s method) were around 0.08 μg L –1 for 5% (v/v) HNO 3 blanks (n = 10) and 0.10 μg L –1 for 5% (v/v) HNO 3 + 0.005 mol L –1 (NH 4 ) 2 S blanks (n = 10). Percent relative standard deviation (%RSD) for five replicate measurements varied between 3.1% and 6.4% at 1.0 CH 3 HgCl level. The method is validated by analysis of two certified reference materials (CRM); purely Methylmercury sediment (SQC1238, 10.00 ± 0.291 ng g –1 CH 3 Hg + ) and Hg-contaminated Estuarine sediment (ERM – CC580, 75 ± 4 ng g–1 CH 3 Hg + and 132 ± 3 μg g –1 total Hg). CH 3 Hg + values for SQC1238 were between 13.0 and 13.2 ng g –1 , and 79 and 81 ng g –1 for ERM – CC580. Hg-contaminated soils (57–96 μg g –1 total Hg) collected from the floodplains of Oak Ridge, TN were analyzed for CH 3 Hg + using the procedure by CVG-ICPMS. CH 3 Hg + levels ranged from 30 to 51 ng g –1 and did not correlate with total Hg levels (R 2 = 0.01).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the strength and fracture toughness of an additive manufactured CrCoNi medium-entropy alloy

An additively manufactured (nominally equiatomic) CrCoNi alloy was processed by laser powder bed fusion (LPBF). At ambient temperatures (298 K), this medium-entropy alloy displayed a yield strength, σ y of ~691 ± 9 MPa, and an ultimate tensile strength, σ u of ~926 ± 15.2 MPa; at cryogenic temperatures (77 K), yield and tensile strengths increased respectively to σ y ~ 944 ± 6 MPa and σ u ~ 1382 ± 11 MPa. These strength levels are 57 and 44% higher than that of the wrought alloy, due to strengthening from the solidification cellular structures intertwined with dislocations in the LPBF CrCoNi. The crack-initiation fracture toughness, K JIc was measured to be ~183.7 ± 28 MPa√m at 298 K; this value marginally decreased by ~4% to ~176 ± 11 MPa√m at 77 K. These K JIc values of the LPBF CrCoNi were 11% and 35% lower than the wrought CrCoNi alloy at 298 K and 77 K, respectively. Here, the resistance to crack growth of the LPBF CrCoNi from its hierarchical micro- and meso-structures was evaluated using nonlinear-elastic fracture mechanics by measuring R-curve behavior in the form of the J-integral as a function of crack extension. The specific features of the hierarchical microstructures at different length-scales provide a basis for the strengthening and toughening properties of this additively manufactured medium-entropy alloy. This correlation between the deformation and the hierarchical microstructures at different length-scales may provide future guidance for improving the fracture toughness properties of medium-entropy alloys.

36 MATERIALS SCIENCE↗

Glass formation during combinatorial sputtering in binary alloys

Glass formation is a complex phenomenon influenced by thermodynamic and kinetic aspects, which are often controlled by extrinsic contributions. While bulk metallic glasses are typically multicomponent alloys, binary alloys offer a simplified approach to studying glass formation. In this study, we fabricated 57 binary alloy systems through combinatorial sputtering, where each alloy system is represented in 66 different alloys. We developed an automated analysis to determine structure and composition using X-ray diffraction and energy-dispersive X-ray spectroscopy for over 3700 alloys. We found that ∼17 % of the alloys form glasses under the estimated cooling rate during sputtering of ∼10 8 K/s. Data analysis revealed that commonly used factors like atomic size ratio and heat of mixing are ineffective in predicting glass formation. However, the crystal structure mismatch of the alloys’ elements emerged as the strongest indicator of glass formation under sputtering conditions of binary alloys. Here, the differences in glass formation under slow cooling rates used for bulk glass formation and the here observed glass formation under rapid cooling rates are discussed.

Binary alloys↗

Active and passive cooling approaches for a Southern California residential community

This study assesses cooling strategies in a low-income community in Southern California that lacks air conditioning and struggles with heat and air pollution. We used an urban building energy model and an electric distribution system model to evaluate active and passive cooling measures. The most effective space cooling measures were high-performance air-source heat pumps, cool coatings, window films, and harnessing the space cooling effect from heat pump water heaters. The results show that combining heat pump water heaters with window films and cool coatings reduces heat index hazard hours within buildings by 95 % to 99 % but increases total energy costs (equipment costs plus changes in utility bills) by 20 % to 60 % where the higher end includes building electrical upgrades. These measures also led to increased space heater use during colder months to avoid overcooling. Replacing conventional heaters with air source heat pumps eliminated unsafe indoor temperatures and reduced total energy use, but increased cost by 125 % to 150 %. In total, using heat pumps for space and water heating could reduce primary energy use by up to 57 %. The higher cost of active and passive cooling measures can be mitigated by existing and emerging incentive programs, especially those that support heat pumps. Electric distribution upgrades to support community electrification are estimated to increase utility costs by $\$$25 to $\$$40 per ratepayer per year. The results underscore the potential and challenges of adapting building infrastructure in communities at risk from climate and environmental stressors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using post-processing heat treatments to elucidate precipitate strengthening of additively manufactured superalloy 718

The poor machinability and extensive work hardening of Ni-based superalloys makes additive manufacturing an attractive option for producing geometrically complex components with distinct microstructures. Although previous studies show recovery of high strength at room temperature, very few studies demonstrate successful properties at elevated temperatures required for industrial applications. Here, the objectives of this study are to present a post-build heat treatment for high strength across a wide temperature range, determine the strength contribution of nanoscale precipitating phases to the overall mechanical properties of superalloy 718, and from these, provide a comprehensive microstructure-property relationship for wrought and AM 718 to guide efforts to simulate the properties of AM components. Laser powder bed fusion–produced superalloy 718 was characterized at multiple length scales using scanning electron microscopy and transmission electron microscopy in the as-built condition and with multiple heat treatments designed to form combinations of γ', γ", and δ precipitates. Uniaxial tensile tests performed from room temperature to 600 °C on subsize specimens determined the yield strength, elastic modulus, ultimate tensile strength, fracture stress, and uniform elongation. Precipitates in this work proved to be weak barriers to dislocation motion through a dispersed barrier model, but they provided strength to the alloy through their consistent high density. The relative contribution to the yield strength from γ" remained consistent between 48% and 57% of the total strength up to 600 °C, the primary influence on the high temperature strength of superalloy 718. The strength factors for γ" and δ precipitates were found to trend inversely with tensile test temperature and may be attributable to the differences in precipitate coherency. A post-build heat treatment is recommended to maintain high strength at elevated temperatures. A quantitative microstructure-property relationship, dependent on precipitate size, density, and morphology, was derived and can estimate the yield strength across a wide temperature range applicable to the operational regimes for superalloy 718.

36 MATERIALS SCIENCE↗