Infrared Metamaterials

This document serves as the final report for the AFRL SBIR Program "Directionally-Tailored Infrared Emission and/or Transmission" AF 1 O-BT30 The focus of this program was in the development and design of a thermal emission surface with thermal emission directed away from broadside in the L WIR band. In the report, a basic overview is provided covering past research efforts in thermal emission surfaces and the fundamental science of directional emitters. Multiple sets of designs are investigated as candidate directional emission surfaces: dark element, image, and end-fire linear array, broadside emitter, and waveguide emitter. Based on program results, both the broadside emitter and waveguide emitter designs appear to meet the needs of the AF directional emission requirements. These designs offer a range of directional emission behavior (controllable emission beamwidth and bandwidth) and scale well to mass production. The designs require additional environmental testing, but appear to be suitable for space application as well. All goals of the program appear to have been met and the team is looking forward to future development.

36 MATERIALS SCIENCE↗

Low Loss Graded Index Polymer Optical Fiber for Local Networking

Here, the objective of this Department of Energy SBIR program has been to develop technology for the advancement of advanced computing systems. NanoSonic worked with two subcontractors, the Polymicro Division of Molex, a U.S.-based manufacturer of specialized optical fiber and fiber components, and Virginia Tech, a research university involved through the Global Environment for Network Innovations (GENI) program in high-speed computer networking research. NanoSonic developed a patented molecular-level self-assembly process to manufacture polymer-based optical fibers in a way similar to the modified chemical vapor deposition (MCVD) approach typically used to make glass optical fibers. Although polymer fiber has a higher attenuation per unit length than glass fiber, short connectorized polymer fiber jumpers offer significant cost savings over their glass counterparts, particularly due to the potential use of low-cost plastic fiber connectors. As part of the SBIR commercialization process, NanoSonic exclusively licensed this technology to a large ($100B+ market cap) U.S.-based manufacturing conglomerate near the end of the first year of the Phase II program. With this base technology developed and licensed, NanoSonic then worked with Polymicro to address secondary program goals of using related but not conflicting production methods to enhance the performance of other specialty optical fiber products and components, and Virginia Tech continued its evaluation of developed polymer fibers in its network infrastructure system on the university campus. We also report our current understanding of the observation during the Phase I program of quantum conductance and partial quantum conductance in metal-insulator-metal (MIM) devices. Such conductance behavior may be modeled as singlemode behavior in one-dimensional electrically conducting waveguides, similar in principle to singlemode optical propagation in dielectric fiber waveguides. Although NanoSonic has not licensed any of the additional technology developed during the second year of the program, several proprietary discussions with major materials companies are underway as of the conclusion of Phase II.

36 MATERIALS SCIENCE↗

Short-Wavelength, High-Power Fiber Laser Sources

This LDRD project investigated novel materials and structures for short-wavelength fiber laser sources. Such sources are desirable for the reduced diffractive spreading of their output beams and for accessing application-specific wavelengths. Furthermore, ongoing developments in short-wavelength diode lasers for data storage and display technologies present an opportunity for power and efficiency scaling of visible fiber lasers based on novel dopant species. Our efforts focused on samarium-doped fibers, pumped at 450 nm and emitting at 651 nm; and neodymium-doped fibers operating on the 3-level transition around 925 nm. While the samarium work was thwarted by material deficiencies, the neodymium work resulted in a novel waveguide design, exceptional lasing results, peer-reviewed publication, and a patent application. This waveguide design has already found application in two other LLNL fiber projects. During the course of this LDRD, we received additional funding to demonstrate a large-core ribbon fiber as a path toward larger mode sizes. As part of this effort, we developed a process for homogenization of doped glasses, as the index uniformity necessary for maintaining mode control (good beam quality) in large core fibers is beyond the capability of standard glassmanufacturing techniques. The resulting fiber showed very good lasing and modal properties, validating both the ribbon concept and the homogenization process.

36 MATERIALS SCIENCE↗

Near-Infrared Nanophotonics through Dynamic Control of Carrier Density in Conducting Ceramics

Major breakthroughs in silicon photonics often come from the integration of new materials into the platform, from bonding III-Vs for on-chip lasers to growth of Ge for high-speed photodiodes. This report describes the integration of transparent conducting oxides (TCOs) onto silicon waveguides to enable ultra-compact (<10 μm) electro-optical modulators. These modulators exploit the "epsilon-near-zero" effect in TCOs to create a strong light-matter interaction and allow for a significant reduction in footprint. Waveguide-integrated devices fabricated in the Sandia Microfab demonstrated gigahertz-speed operation of epsilon-near-zero based modulators for the first time. Numerical modeling of these devices matched well with theory and showed a path for significant improvements in device performance with high-carrier-mobility TCOs such as cadmium oxide. A cadmium oxide sputtering capability has been brought online at Sandia; integration of these high mobility films is the subject of future work to develop and mature this exciting class of Si photonics devices.

36 MATERIALS SCIENCE↗

Seamless Hybrid-integrated Interconnect NEtwork (SHINE)

Large-scale date centers are becoming increasingly limited by the capacity of interconnects due to the rapid increasing power consumption and bandwidth demands driven by the rigorous down scaling of CMOS critical dimensions in according with the Moore’s Law. As a result of the continuing bandwidth scaling, optical interconnects based on parallel optics, where data are simultaneously transmitted along more than one lane, have becoming a preferred interconnected solution over copper cables. To building an efficient optical interconnect system, optical coupling between different elements, such as optical fibers, photonics chips, is a critical step, which is challenging due to the mode mismatch of varies optical ports. In this project, we proposed and demonstrated an optical interfacing scheme, which provided a light coupling approach with low energy loss, broadband operation, high alignment tolerance and compatible with scalable fabrication and testing. Here, the mode transformation is achieved by a total internal reflection from a chip integrated microscale freefrom surface. Due to the enormous light wavefront manipulating ability associated with the gigantic design space, the freeform couplers platform is universally applicable to a wide range of optical coupling scenarios, such as the interfacing between a waveguide to a fiber, another waveguide, surface normal device, or free space.

42 ENGINEERING↗

Report on Depth-Dependent Q from Frequency-Dependent Lg Q

As a phase that travels through the crustal waveguide, Lg samples the velocity and attenuation structure of the crust. We have developed methods (Pasyanos et al., 2009a; Pasyanos et al., 2009b) to estimate Qp and Qs of the crust and upper mantle from the amplitudes of regional phases, and have applied it to a number of regions around the world, and over a broad frequency band (0.5 - 10 Hz). In prior attenuation modeling, Lg phase amplitudes are able to effectively distinguish the high Q (low attenuation) of old stable cratonic crust from the low Q (high attenuation) of more recently active tectonic regions. For a variety of purposes (e.g. waveform modeling, seismic hazard, etc.), it is useful to have more information on the depth-dependence of the Q structure in the crust. One obvious candidate for doing this is using the frequency-dependence information of Lg Q, in the manner of surface waves. Unfortunately, however, Lg samples the whole of the crust without much differentiation with respect to frequency that is characteristic of fundamental mode surface waves. Lg is generally thought to be the sum of supercritically reflected S-waves trapped in the crustal waveguide (e.g. Xie and Lay, 1994). The phase can also be modeled as a superposition of surface waves. At lower frequencies, it is primarily composed of fundamental and low-order surface waves, while at higher frequencies, it is comprised purely of many high-order surface waves. The low-order surface waves that comprise Lg in low frequency bands (< 1 Hz) are preferentially sensitive to shallow earth structure, such as sedimentary basins and upper crust, while high-order surface waves have a more homogenized sensitivity to the whole crust. Furthermore, at the lower frequencies, we might expect to see some differentiation in the sensitivity between early Lg (herein referred to as Lg1) and late Lg (referred to as Lg2) where the latter is comprised of lower-order surface waves and, hence, shallower structure. Therefore, we might expect to see the signature of shallow features, primarily the lower Q of sediments as compared to crystalline crust, at lower frequencies and in later arriving Lg amplitudes.

58 GEOSCIENCES↗

Second Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed. Approximate figure of merit of sensitivity to flow rate is 100KHz/GPM. In addition, we have identified an existing liquid sodium experimental setup for demonstration of flow sensing in environment similar to that of an advanced reactor. The setup consists of a cylindrical vessel and center feed line, where transducer inserted through the lid will measure velocity of the impinging liquid jet. As a calibration experiment, we have assembled a water vessel with center feed with the same dimensions as those of the liquid sodium setup. We have also developed and insertion probe consisting of a 50cm brass waveguide enclosed in protective SS316 tube. Using the water loop, we have demonstrated feasibility of sensing the impinging liquid jet in the vessel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Internship Experience

I started my internship in January 2022 but the research on measuring dispersion and loss of 355nm light from a silicon oxide waveguide began in August 2022 which will be the focus of this paper. The motivation of this project is to determine whether it is possible to use pulsed 355nm light in an integrated waveguide within an ion trap chip. To begin this project, light from the 355nm Coherent Paladin laser was coupled into a fiber which will be referred to as the “source fiber.” After coupling into a fiber, loss and dispersion measurements could be performed as this fiber was used to deliver light to each of the experiments which will be covered in detail in the following paragraphs.

42 ENGINEERING↗

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Coherent Wavelength Switched Co-Packaged Optics to Disrupt Datacenters/HPC (AKA "QRock") (Final Report)

This project resulted in multiple first-of-a-kind demonstrations, including two generations of transmitters, a receiver, and a complete coherent link. The transmitter architecture, based on EAMs to generate QPSK modulation was first demonstrated in InP, which has limitations for scaling up to chips with multiple channels for full WDM architectures, and implementing the densities and level of integration needed to implement co-packaging with electronics. Our work resulted in the first demonstration of this architecture on a Si platform compatible with copackaging, and our working prototypes illustrated the potential of the approach. The link demonstration was also the first coherent optical link realized in a multi-micron waveguide platform. For the transmitters, integrating efficient III-V EAM devices into the large waveguide Si platform simultaneously enables significant reduction in driver power consumption while minimizing optical losses in routing and fiber coupling. On the receiver side, optical coupling and propagation losses are also minimized in the multi-micron platform, reducing required laser optical power which improves link energy efficiency. The measurement results presented in the final report demonstrate that we achieved the speed objectives for the program (112Gb/s: 56Gbaud QPSK), albeit at a higher BER than targeted. The report provides assessments of the low-powercoherent link architecture and associated components developed under the program from both technological and commercial viewpoints.

97 MATHEMATICS AND COMPUTING↗

Development of INL Ultrasonic Thermometer

This document summarizes the development at Idaho National Laboratory of an ultrasonic thermometer. The ultrasonic thermometer is a temperature sensor capable of multi-point measurements at very high temperatures with a high level of radiation tolerance. All of the components of the ultrasonic thermometer have been improved over the course of this work. The base technology, a magnetosrictive transducer, has been shown to be highly radiation tolerant. The solenoidal coil used in the transducer has been redesigned to operate at higher frequencies that previously possible. Materials used for the acoustic waveguide (the sensing portion of the device) have been tested and ideal candidates identified. Finally, a solution to the sticking issue (diffusion bonding between the waveguide and a protective sheath) has been developed and tested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SIREN: Scaling Ion-Traps by REquiring iNnovative Heterogenous Integration

The SIREN (Scaling Ion Traps by Requiring iNnovative heterogenous integration) project explores the feasibility of heterogeneous integration (HI) as a transformative approach to scaling ion traps, a critical technology for advancing quantum computers and atomic clocks. Traditional ion trap architectures face significant challenges in scalability due to limitations in optical access, fabrication techniques, and material constraints. SIREN addresses these challenges by leveraging HI, which combines different materials and fabrication processes to create more complex and efficient ion trap structures. HI integrated structures can be manufactured without compromising the process to maintain compatibility to ion traps. This project focuses on integrating a separately fabricated waveguide with a fully functional ion trap. The respective alignment between the pieces needs to be accurate to less than 2 µm to ensure that the light from the waveguide can overlap with the trapping region. The fine alignment must also be maintained through an ultra-high vacuum bake, a critical step in preparing an ion trap experiment. The project's outcomes suggest that heterogeneous integration is a promising pathway for overcoming current scalability barriers, paving the way for the next generation of quantum technologies. SIREN's findings contribute significantly to the field, offering a scalable solution that could accelerate the development of practical quantum computers and highly accurate atomic clocks.

42 ENGINEERING↗

Ion Traps and Packaging for Heterogenous Integration - Chimera

Microfabricated surface ion traps and silicon-based photonics are critical technologies for scaling quantum systems. Current ion trap architectures face scalability and integration challenges due to limitations in optical access, fabrication techniques, and material compatibility. State-of-the-art quantum computers and atomic clocks are investigating monolithic integration, which necessitates custom traps for each ion species and has not overcome the integration hurdles presented by merging these technologies. The Chimera (Ion Traps and Packaging for Heterogeneous Integration) project proposes a novel approach utilizing heterogeneous integration (HI) of ion traps and photonic circuits. This separation of components allows for flexibility in ion trap design and reduces fabrication compromises. The Chimera project specifically designed an ion trap to interface vertically with a separately fabricated waveguide chip and demonstrates the first steps to integrating them at the packaging level. The ion trap features a large area of removed silicon, allowing the photonics chip outputs closer to the ion trap, improving alignment and packaging processes. The alignment must be accurate to < 1 µm to ensure that the light from the waveguide can overlap with the trapping region. This fine alignment must also be maintained through an ultra-high vacuum bake, a critical step in preparing an ion trap experiment. By combining separate chips, we demonstrate a new path for scaling trapped ion technology that is less reliant on monolithic integration. We successfully fabricated a trap with a large area of oxide removed, resulting in a region thinned to about 40 µm, a key milestone toward successful integration.

42 ENGINEERING↗

Optical Biosensor Platforms Display Varying Sensitivity for the Direct Detection of Influenza RNA

Detection methods that do not require nucleic acid amplification are advantageous for viral diagnostics due to their rapid results. These platforms could provide information for both accurate diagnoses and pandemic surveillance. Influenza virus is prone to pandemic-inducing genetic mutations, so there is a need to apply these detection platforms to influenza diagnostics. Here, we analyzed the Fast Evaluation of Viral Emerging Risks (FEVER) pipeline on ultrasensitive detection platforms, including a waveguide-based optical biosensor and a flow cytometry bead-based assay. The pipeline was also evaluated in silico for sequence coverage in comparison to the U.S. Centers for Disease Control and Prevention’s (CDC) influenza A and B diagnostic assays. The influenza FEVER probe design had a higher tolerance for mismatched bases than the CDC’s probes, and the FEVER probes altogether had a higher detection rate for influenza isolate sequences from GenBank. When formatted for use as molecular beacons, the FEVER probes detected influenza RNA as low as 50 nM on the waveguide-based optical biosensor and 1 nM on the flow cytometer. In addition to molecular beacons, which have an inherently high background signal we also developed an exonuclease selection method that could detect 500 pM of RNA. The combination of high-coverage probes developed using the FEVER pipeline coupled with ultrasensitive optical biosensors is a promising approach for future influenza diagnostic and biosurveillance applications.

59 BASIC BIOLOGICAL SCIENCES↗

Thermal Frequency Drift of 3D Printed Microwave Components

Fabrication of microwave slot array antennas and waveguide bandpass and notch filters using 3D printing has significant advantages in terms of speed and cost even for parts with high mechanical complexity. One disadvantage of Stereolithography (SLA) 3D printed, copper plated microwave components is that some SLA resins have a high Coefficient of Thermal Expansion (CTE), quoted in micrometers per meter per degree or 10 -6 per degree. Compared to typically used metals such as aluminum (CTE 24 × 10 -6 ·K -1 ) and copper (CTE 17 × 10 -6 ·K -1 ), SLA resin can have CTE above 100 × 10 -6 ·K -1 . Resonant structures experience significant frequency drift with temperature changes on the order of 10–50 °C. The issue of 3D printed microwave structures changing frequency characteristics significantly with temperature shift has not been addressed or reviewed in current literature. We measured and simulated the effect of temperature change on a slot array, cavity notch filters, and post loaded waveguide bandpass filters. We tested several types of SLA resin, different plating techniques, and also Direct Metal Laser Sintering (DMLS) and Binder Infusion metal 3D printing. Performance as a function of temperature is presented for these alternatives.

three-dimensional printing↗

Spindown of Pulsars Interacting with Companion Winds: The Impact of Magnetospheric Compression

Pulsars in binary systems with strong companion winds can have the magnetopause separating their magnetosphere from the wind located well within their light cylinder. This bow-like enclosure effectively creates a waveguide that confines the pulsar's electromagnetic fields and can significantly alter its spindown. In this paper, we study the spindown of compressed pulsar magnetospheres in such systems. We parameterize the confinement as the ratio between the equatorial position of the magnetopause (or standoff distance) R m and the pulsar's light cylinder R LC . Using particle-in-cell simulations, we quantify the pulsar spindown for a range of compressions, R m /R LC = 1/3–1, and inclination angles, χ = 0°...90°, between magnetic and rotation axes. Our strongly confined models (R m /R LC = 1/3) show two distinct limits. For χ = 0°, the spindown of a compressed pulsar magnetosphere is enhanced by approximately a factor of three compared to an isolated pulsar due to the increased number of open magnetic field lines. Conversely, for χ = 90°, the compressed pulsar spins down at less than 40% of the rate of an isolated reference pulsar due to the mismatch between the pulsar wind stripe wavelength and the waveguide size. We apply our analysis to the 2.77 s oblique rotator (χ = 60°) in the double-pulsar system PSR J0737-3039. With the numerically derived spindown estimate, we constrain its surface magnetic field to B* ≈ (7.3 ± 0.2) × 10 11 G. We discuss the time modulation of its period derivative, the effects of compression on its braking index, and implications for the radio eclipse in PSR J0737-3039.

79 ASTRONOMY AND ASTROPHYSICS↗

Dielectric Resonator Design for Low Power and Low Temperature Microwave Plasma

Waveguide-based microwave plasmas generally operate at high temperatures (2000 - 6000K)[1], making it difficult to directly interface solid materials with the plasma without significant thermal damage. Dielectric microwave resonators (DMRs), long studied for wave-based manipulation of electromagnetic radiation for telecom and optics, can focus radiation to extremely small mode volumes, creating intense localized fields with low-power input.[2] This phenomenon can be used for applications ranging from efficient plasma electronics to near-ambient plasma-materials interactions. Such DMR-based plasmas have been demonstrated a handful of times in the literature, but the majority of research towards this utilize the lowest frequency resonance mode.[3], [4], [5] By carefully controlling the geometry of cylindrical resonators, a variety of electromagnetic modes can be excited. In this work, COMSOL Multiphysics simulations are used to study the electric field enhancement and absorption properties of CaTiO3 DMRs as a function of geometry and excitation frequency. Whereas previous studies have utilized the HEM111 resonance frequency to drive low power plasma excitation, we find that higher order resonance frequencies are more effective at field enhancement and result in less power loss within the dielectric material, hence less wasted heating. The effectiveness of these modes is also geometry dependent and can be computationally optimized for plasma generation. Complementing these computational efforts, we demonstrate a new closed-system reactor design built in a WR-650 waveguide and experimentally demonstrate the formation of atmospheric argon microwave plasma using < 30 W input power on DMR dimers. We observe a shifting resonance frequency as the DMRs heat in response to microwave excitation and develop a Python-based lock-in mechanism to effectively track the DMR resonance over time, leading to stable plasma operation. We use infrared thermal imaging to monitor the temperature of the DMR dimers and surrounding quartz chamber, demonstrating thermal temperatures < 60 degreesC. Finally, we utilize optical emission spectroscopy (OES) to probe the plasma properties as a function of the resonance mode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mode Conversion Losses in Expansion Units for ITER ECH Transmission Lines

The ITER electron cyclotron heating transmission lines will consist of 63.5 mm diameter corrugated waveguides, each carrying 1 MW of 170 GHz microwaves. These transmission lines must include expansion units to accommodate expansion and contraction along the path from the gyrotron microwave sources to the tokamak. A numerical mode matching code has been developed to calculate power losses due to mode conversion of the operating mode, HE11, to higher order modes as a result of the radial discontinuities in a sliding joint. Two expansion unit designs were evaluated, a simple gap expansion unit and a more complex tapered expansion unit. The gap expansion unit demonstrated loss that oscillated rapidly with expansion length, due to trapped modes within the unit. The tapered expansion unit has been shown to effectively suppress these trapped modes at the expense of increased fabrication complexity. In a gap expansion unit, for a waveguide step size of 2.5 mm, loss can be kept below 0.1% to a maximum expansion length of 17 mm. Expansion units without corrugation on interior walls were also evaluated. Expansion units that lack corrugations are found to increase mode trapping within the units, though not beyond useful application. The mode matching code developed in this paper was also used to estimate mode conversion loss in vacuum pumpouts for the ECH lines; the estimated loss was found to be negligibly small.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗