Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vessel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

The AP1000{sup R} China projects move forward to construction completion and equipment installation

The AP1000 design is the only Generation III+ technology to receive design certification from the U.S. Nuclear Regulatory Commission. This evolutionary design provides the highest safety and performance standards and has several distinct advantages over other designs, including improved operations and reduced construction schedule risks through the use of modern, modular, engineering principles that allow construction and fabrication tasks traditionally performed in sequence to be undertaken in parallel. Since the first granting of Design Certification in 2005 by the NRC, the AP1000 design has been modified to meet emergent NRC requirements such as those requiring the design to withstand the impact of an aircraft crash. Both domestic and foreign utilities have turned to the Westinghouse AP1000 plant design to meet their near - and long-term sustainable energy needs. The first ever deployment of this advanced U.S. nuclear power technology began in China in 2007 with the award of a contract to build four AP1000 units, constructed in pairs at the coastal sites of Sanmen (Zhejiang Province) and Haiyang (Shandong Province). Currently, all four units are at an advanced stage of construction. The commercial operation date for Sanmen Unit 1 is November 2013 followed by Haiyang Unit 1 being operational in May 2014. Construction and equipment manufacture is at an advanced stage. Sanmen Unit 1 equipment that has been delivered includes the reactor vessel, the reactor vessel closure head, the passive residual heat removal heat exchanger, the integrated head package, the polar crane, and the refueling machine. The steam generators are also completed. The RV was installed within the containment vessel building in September 2011. The installation of this major equipment will allow the setting of the containment vessel top head. Haiyang Unit 1 is also achieving significant progress. Significant benefits continue to be realized as a result of lessons learned and experience gained from the first-of-a-kind activities for Sanmen Unit 1 and AP1000 equipment design and manufacturing. For example, the nuclear island basemat at Haiyang Units 1 and 2 and Sanmen Unit 2 was laid in less time than that of Sanmen Unit 1, the ultra-large steam generator and RV forging lead times were reduced for the follow on units, and the fabrication of the auxiliary building module for Haiyang Unit 1 took less time than for the Sanmen first unit. These benefits are also being realized by the United States AP1000 project construction and fabrication modules, and equipment. Some difficulties arise from building this first-of-a-kind (advanced passive) type of plant; however, these difficulties are being overcome and the overall schedule remains achievable. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Water Sealing With NOH{sub 2}O on the Fukushima Site - 17477

The Fukushima Daiichi nuclear site is still recovering from the natural disaster of March 11, 2011. Much of the recent recovery work has been focused on mitigating ground water intrusion into the radioactively contaminated basements of the reactor and turbine buildings of units 1 - 4. Other recovery efforts involve potentially sealing the vent lines in the primary containment vessels of units 1 - 3 to maintain a flooded vessel for core cooling and shielding. This paper details preliminary test results of a proprietary grout - NOH{sub 2}O{sup TM} - in sealing/plugging those vent lines to allow flooding of the primary containment vessel. Several partial and full-scale tests were conducted on primary containment vessel vent line mock-ups between March and October 2015 to ascertain the effectiveness of NOH{sub 2}O in sealing vent lines that have flowing water, which is problematic for conventional cement-based grouts that require relatively protracted set times. In contrast, NOH{sub 2}O can be used with a proprietary accelerant to provide instant set. The other key advantage of NOH{sub 2}O is its ability to penetrate even the smallest of cracks and porous soils, following and moving with the water flow and creating a continuous, impermeable barrier. It is also extremely flexible once set, conforming to its enclosure as upstream water head increases. Finally, the material's extremely high radiation resistance and longevity make it an ideal candidate for a permanent solution in high rad environments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of thermal transit flow measurement for small modular reactors - 140

Safe, reliable, and efficient operation of nuclear reactors requires timely and accurate measurement of primary coolant parameters such as temperature, flow, pressure, and level. These measurements may be challenging in small modular reactors (SMRs) with integral vessel design. For SMRs with the integral design, sensors may be located in confined spaces or embedded within pressure vessels. The absence of primary coolant loops is another fundamental design attribute that will affect the location of sensors, sensor interfaces, and types of sensors suited for process parameter measurements. Further, the number and location of pressure vessel penetrations may be constrained compared to traditional nuclear power plants (NPPs). As a result, conventional NPP temperature, flow, pressure, and level sensors may not be appropriate for use in SMRs. This paper addresses the development of new sensor technology for hybrid temperature, flow, and level measurement. The authors demonstrate the alternative use of resistance temperature detectors (RTDs) where cross-correlation of process temperature variations between RTDs is used to calculate process flow velocity. The new sensor and measurement technology will also incorporate RTD response time and self-heating characteristics to provide flow and level measurement in accident conditions. This capability would simplify reactor design and enable optimal placement of reactor pressure vessel penetrations leading to increased operational reliability and safety. The cross-correlation of temperature signals and adaptation for flow measurement in a laboratory setting is presented here. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulations of a Helical Tube Bundle in Cross-Flow for Application to Flow-Induced Vibration

Helical tubes have been used in a number of systems, including the energy and chemical processing industries. Helical-Coil Steam Generators (HCSGs) in particular have special application in systems for which spatial constraints are important. Variants of these designs are notably included in a number of integral-vessel small modular reactor (SMR) designs which are currently in development by multiple companies. These designs typically have the primary side located within the vessel, with the secondary side flowing upward through the helical tubes. One complexity in implementing an HCSG within the reactor pressure vessel is that any potential flow-induced vibration (FIV) can impact reactor safety. In a typical power plant, heat exchanger tube failures caused by FIV can be costly, but generally do not have immediate impact on the core safety due to their relative isolation from the core area. In an integral-vessel design, a tube rupture could eject material from the secondary side into the primary flow, potentially damaging the core itself or other crucial components. Thus a higher degree of confidence in predicting and/or preventing FIV should be attained for implementing the helical tubes in these designs. A significant campaign is currently underway to address the topic of FIV in helical tube arrays. The U.S. Department of Energy, under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) initiative, has deemed this a 'high-impact problem'. This will include both experimental and computational contributions from a consortium consisting of multiple universities, industry partners, and national laboratories, including Argonne National Laboratory. The primary industrial partner is NuScale, which will see direct benefits from this initiative to the development of their SMR and its component design. The primary focus of this paper is to establish some of the computational efforts that have been made to this stage and the initial benchmarking of computational tools. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Crural Artery Traumatic Injuries: Treatment with Embolization

The purpose of this paper is to report our experience with the endovascular treatment of crural arterial injuries using transcatheter and direct embolization techniques. A total of eight consecutive patients have been treated during a 7-year period. Six males and two females, mean age 32 years (range, 15-56 years), presented with penetrating trauma to the lower extremities. Mechanisms of injuries were stab wounds in six patients, gun shot wound in one patient, and iatrogenic injury in one patient. Five patients presented with acute trauma, while three patients presented with delayed injuries. Crural arterial injuries encountered included pseudoaneurysms with arteriovenous fistulas (n = 6), pseudoaneurysms with vessel transections (n = 2), and pseudoaneurysm (n = 1). Proximal and distal embolization with coils was used in three cases, proximal embolization with coils in three cases, percutaneous thrombin injection in one case, and liquid n-butyl cyanoacrylate in one case. Complete exclusion of the lesions was accomplished by sacrifice of one crural vessel in seven cases and of two crural vessels in one case. Two cases of delayed injuries required combined coil and liquid embolization techniques for lesion exclusion. A minor complication (groin hematoma) occurred in one patient, no distal ischemia was seen, and no amputations were required. Mean follow-up was 61 days (range, 1-180 days). One pseudoaneurysm treated with thrombin injection recurred and required surgical excision. We conclude that transcatheter embolization alone or in combination with different endovascular techniques is useful in the treatment of traumatic crural vessel injuries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temporary Arterial Balloon Occlusion as an Adjunct to Yttrium-90 Radioembolization

Purpose. This study was designed to describe the technique of arterial occlusion using a temporary occlusion balloon system as an alternative to coil occlusion during Yttrium-90 radioembolization of hepatic tumors. Methods. Review of charts, angiography, and follow-up imaging studies of consecutive patients undergoing oncological embolization procedures in which a HyperForm system (ev3 Neurovascular, Irvine, CA) was used. Intraprocedural target vessel occlusion and patency of the target vessel on follow-up were recorded. Clinical data and Bremsstrahlung scans were reviewed for evidence of nontarget embolization. Results. Four radioembolization procedures were performed in three patients (all female, age 48-54 (mean 52) years). Five arteries were temporarily occluded (three gastroduodenal arteries, one right gastric artery, and one cystic artery). All radioembolization procedures were successfully completed. Follow-up imaging (either digital subtraction angiography (DSA) or computed tomography angiography (CTA)) was available for all patients between 28-454 (mean 183) days following the procedure, demonstrating all five vessels to be patent. No clinical or imaging evidence for nontarget embolization was found. Conclusions. Temporary balloon occlusion of small and medium-sized arteries during radioembolization allows safe therapy with preserved postprocedural vessel patency on early and midterm follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Endovascular Salvage Techniques for Implanted Venous Access Device Dysfunction

PurposeImplanted venous access devices (IVADs) are often used in patients who require long-term intravenous drug administration. The most common causes of device dysfunction include occlusion by fibrin sheath and/or catheter adherence to the vessel wall. We present percutaneous endovascular salvage techniques to restore function in occluded catheters. The aim of this study was to evaluate the feasibility, safety, and efficacy of these techniques.Methods and MaterialsThrough a femoral or brachial venous access, a snare is used to remove fibrin sheath around the IVAD catheter tip. If device dysfunction is caused by catheter adherences to the vessel wall, a new “mechanical adhesiolysis” maneuver was performed. IVAD salvage procedures performed between 2005 and 2013 were analyzed. Data included clinical background, catheter tip position, success rate, recurrence, and rate of complication.ResultsEighty-eight salvage procedures were performed in 80 patients, mostly women (52.5 %), with a mean age of 54 years. Only a minority (17.5 %) of evaluated catheters were located at an optimal position (i.e., cavoatrial junction ±1 cm). Mechanical adhesiolysis or other additional maneuvers were used in 21 cases (24 %). Overall technical success rate was 93.2 %. Malposition and/or vessel wall adherences were the main cause of technical failure. No complications were noted.ConclusionThese IVAD salvage techniques are safe and efficient. When a catheter is adherent to the vessel wall, mechanical adhesiolysis maneuvers allow catheter mobilization and a greater success rate with no additional risk. In patients who still require long-term use of their IVAD, these procedures can be performed safely to avoid catheter replacement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of Calibrated Gelatin Sponge Particles in a Rabbit Renal Embolization Model

Purpose: To evaluate the level of artery occlusion, degradation periods, tissue response and vessel recanalization of calibrated gelatin sponge particles after segmental renal artery embolization. Materials and Methods: Superselective embolization of 14 adult rabbits was performed with calibrated gelatin sponge particles (150–350 μm). Two rabbits were killed immediately after the procedure (day 0). One pair of rabbits was killed on each of the following days: 1, 3, 7, 14, 28 and 56. One rabbit from each pair underwent CT angiography before embolization and killing. The pathologic changes of the embolized renal parenchyma and embolic characteristics of calibrated gelatin sponge particles were evaluated histologically and angiographically. Results: Calibrated gelatin sponge particles were distally located in interlobular artery with a dense packing on day 0. The level of occlusion paralleled the size of the particles. Partial degradation of the particles was observed on day 3, and complete degradation was observed on day 14. Vessel recanalization was observed through both CTA and histological analysis starting on day 3. Vascular inflammation responding to gelatin sponge particles was mild and subsided with the degradation of the particles. On day 28 and day 56, attenuation of embolized vessels occurred due to marked intimal proliferation, and vascular occlusion developed. Conclusions: Gelatin sponge particles of 150–350 μm produced dense and distal embolization, and were resorbed before day 14 with a mild tissue reaction. Vessel recanalization occurred secondary to the resorption of gelatin sponge particles, but permanent vascular occlusion developed due to marked intimal hyperplasia after day 28.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improvements to the High-Field-Side Transient CHI System on QUEST

Transient coaxial helicity injection (CHI) is a promising candidate for solenoid-free plasma current start-up in a low-aspect-ratio tokamak in support of developing fully non-inductive scenarios. The aim of the transient CHI research on QUEST is to develop a reactor-relevant CHI design. On QUEST, a CHI discharge is initiated by driving current along magnetic field lines that connect an electrically insulated electrode plate (which is referred to as a bias electrode) to a vessel component at the bottom region of the spherical tokamak. In the first application of CHI on QUEST, the electrically insulated electrode plate was biased with respect to the outer vessel in a configuration referred to as low-field-side (LFS) injection. To maintain a narrow injector flux footprint width throughout the discharge, QUEST is now developing a high-field-side (HFS) injection configuration, in which the electrically insulated electrode plate is biased with respect to the inner vessel components. Through the implementation of a CHI-dedicated gas injection system, studies in the HFS injection configuration have now demonstrated good magnetic flux evolution into the vacuum vessel. Toroidal currents up to 43 kA have been achieved, and the generated current has increased in proportion to the magnetic flux connecting the electrodes. Finally, these results which show agreement with the CHI-scaling suggest that much higher levels of toroidal current can be generated on QUEST in an optimized CHI system in which the magnetic flux connecting the CHI electrodes is further increased.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distinct expression patterns of Flk1 and Flt1 in the coronary vascular system during development and after myocardial infarction

Highlights: • Flk1 is expressed in ECs with an epicardial-to-endocardial transmural gradient. • Flt1 is homogeneously expressed in ECs in neonatal and adult mouse hearts. • Flk1 is transiently induced but Flt1 is maintained in coronary vessels after MI. • The kinetics of Flk1 and Flt1 after MI recapitulates that in cardiac development. The coronary vascular system is critical for myocardial growth and cardiomyocyte survival. However, the molecular mechanism regulating coronary angiogenesis remains elusive. Vascular endothelial growth factor (VEGF) regulates angiogenesis by binding to the specific receptors Flk1 and Flt1, which results in different functions. Despite the importance of Flk1 and Flt1, their expression in the coronary vasculature remains largely unknown due to the lack of appropriate antibodies for immunostaining. Here, we analyzed multiple reporter mice including Flk1-GFP BAC transgenic (Tg), Flk1-LacZ knock-in, Flt1-DsRed BAC Tg, and Flk1-GFP/Flt1-DsRed double Tg animals to determine expression patterns in mouse hearts during cardiac growth and after myocardial infarction (MI). We found that Flk1 was expressed in endothelial cells (ECs) with a pattern of epicardial-to-endocardial transmural gradients in the neonatal mouse ventricle, which was downregulated in adult coronary vessels with development. In contrast, Flt1 was homogeneously expressed in the ECs of neonatal mouse hearts and expression was maintained until adulthood. After MI, expression of both Flk1 and Flt1 was induced in the regenerating coronary vessels at day 7. Intriguingly, Flk1 expression was downregulated thereafter, whereas Flt1 expression was maintained in the newly formed coronary vessels until 30 days post-MI, recapitulating their expression kinetics during development. This is the first report demonstrating the spatiotemporal expression patterns of Flk1 and Flt1 in the coronary vascular system during development and after MI; thus, this study suggests that these factors have distinct and important functions in coronary angiogenesis.

60 APPLIED LIFE SCIENCES↗

Thermal Loads and Cooling Design for ITER in-Port Low Field Side Reflectometer Diagnostic System

The current design for the ITER Low Field Side Reflectometer (LFSR) diagnostic system contains six circular waveguides that function as both launch and receive antennas. The front end of LFSR system, interfacing with the plasma facing DFW and its supporting diagnostic shielding Modules (DSM), is integrated into Equatorial Port Plug 11(EPP#11). In-vessel LFSR configuration is mainly divided into two sections, i.e. Front Antenna Unit (FAU) and in-vessel Transmission Line (TL) components. During plasma normal operation, the 14 MeV neutrons from D-T fusion reactions penetrate into the port plug and LFSR components. Neutronics code ATTILA is used for assessing the volumetric heating of in-vessel components. The maximum normal heat load due to radiation and the charge exchange from plasma is 0.35 MW/m 2 , which has to be applied on those surfaces affected by a viewing factor consistent with the aperture surface position and orientation. The front antenna unit (FAU) needs the active cooling to handle the radiant and nuclear heating from the plasma. Due to the specific viewing aperture layout at the front-end of in-vessel LFSR, the cooling channel design is challenging. The thermal-hydraulic iterations are performed to achieve the desirable temperature distribution of the water cooled front antenna units. The progressive ratcheting effects of the FAU subjected to cyclic thermal loading are examined by the preliminary non-linear elastic-plastic analysis.

42 ENGINEERING↗

Techno-economic analysis of conventional and advanced high-pressure tube trailer configurations for compressed hydrogen gas transportation and refueling

Transporting compressed gaseous hydrogen in tube trailers to hydrogen refueling stations (HRSs) is an attractive economic option in early fuel cell electric vehicle (FCEV) markets. This study examines conventional (Type I, steel) and advanced (Type IV, composite) high-pressure tube trailer configurations to identify those that offer maximum payload and lowest cost per unit of deliverable payload under United States Department of Transportation (DOT) size and weight constraints. The study also evaluates the impacts of various tube trailer configurations and payloads on the transportation and refueling cost of hydrogen under various transportation distance and HRS capacity scenarios. Composite tube trailers can transport large hydrogen payloads, up to 1100 kg at 7300 psi (500 bar) working pressure, while steel tube trailer configurations are limited by DOT weight regulations and may transport a maximum hydrogen payload of approximately 270 kg. Using steel pressure vessels to transport hydrogen at high pressure is counterproductive because of the rapid increase in vessel weight with wall thickness. The most economic composite tube trailer configuration includes 30-inch-diameter vessels packed in a 3 x 3 array. A linear relationship between the deliverable payload and the capital cost of a composite tube trailer has been developed for configurations with the lowest cost-per-unit payload. The capital cost is approximately $1100 per kg of deliverable hydrogen payload. Considering the entire delivery pathway (including refueling), tube trailer configurations with smaller vessels packed in greater numbers enable higher payload delivery and lower delivery cost in terms of $/kg H-2, when delivering hydrogen over longer distances to large stations. Selection of the appropriate tube trailer configuration and corresponding hydrogen payload can reduce hydrogen delivery cost by up to 16%. (C) 2018 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.

composite tubes↗

The Effect of a Contrast Agent on Proton Beam Range in Radiotherapy Planning Using Computed Tomography for Patients With Locoregionally Advanced Lung Cancer

Purpose: We evaluated the effect of a contrast agent (CA) on proton beam range in a treatment planning system (TPS) for patients with locoregionally advanced lung cancer. Methods and Materials: Two sets of computed tomography (CT) images (with and without CA) were obtained from 20 patients with lung cancer. Because the increase in Hounsfield unit ( Increment HU) value of the heart and great vessels due to the effect of CA is most prominent among thoracic structures, to evaluate the effect of CA on proton beam range in the TPS, we compared the calculated distal ranges in the plan with CA-enhanced CT with those with corrected CT, in which the HU values of the heart and great vessels in the CA-enhanced CT were replaced by average HU values obtained from the unenhanced CT. Results: The mean Increment HU value and the longest length of the heart and great vessels within the proton beam path in the field that passed through these structures were 189 {+-} 29 HU (range, 110-250 HU) and 7.1 {+-} 1.1 cm (range, 2.6-11.2 cm), respectively. The mean distal range error in the TPS because of the presence of CA was 1.0 {+-} 0.7 cm (range, 0.2-2.6 cm). Conclusion: If CA-enhanced CT images are used for radiotherapy planning using a proton beam for the treatment of lung cancer, our results suggest that the HU values of the heart and great vessels should be replaced by the average HU values of soft tissue to avoid discrepancies between planned and delivered doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of numerical models for seismic fluid-structure-interaction analysis of nuclear, safety-related equipment

Seismic design, qualification, and risk assessment of nuclear safety-related vessels filled with liquid will have to consider the interaction between the vessel (tank), the contained liquid, and submerged components, if any. Seismic fluid-structure-interaction (FSI) analysis of nuclear vessels will rely on numerical models, which are required to be verified and validated. This study validates previously-verified numerical models using test data generated from earthquake-simulator experiments involving a cylindrical tank. Two solvers in LS-DYNA for FSI simulations are used for the numerical analysis: Arbitrary-Lagrangian-Eulerian (ALE) and Incompressible Computational Fluid Dynamics (ICFD). Numerical and test results are compared for responses critical to seismic design of advanced reactor vessels: hydrodynamic pressures on the tank wall, reactions at the support, and wave heights of the contained liquid. Analysis is performed for one-, two-, and three-directional seismic inputs with a range of intensity, and rocking motions. The accuracy of the numerical results and different methods for outputting wave heights are discussed. Recommendations for validation of seismic FSI numerical models of advanced reactors are provided. As a result, the validation exercise presented in this study is broadly applicable to cylindrical tanks, regardless of industry sector.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Mid-height seismic isolation of equipment in nuclear power plants: Numerical simulations and design recommendations

Seismic isolation can mitigate earthquake demands on safety-class equipment and is being considered for application to some advanced nuclear reactors. For tall, slender vessels that could represent an advanced reactor, a steam generator or a heat exchanger, mid-height seismic isolation has been shown to be beneficial and practical. Here, this paper focuses on numerical modeling of a mid-height isolated tall, slender vessel with two primary goals 1) investigate and quantify the benefits of mid-height seismic isolation for a range of support structure stiffnesses, isolation systems, and seismic inputs, and 2) provide analysis and design recommendations for isolation of safety-class equipment. Results of response-history analysis were in good agreement with experimental measurements and demonstrated that mid-height isolation can substantially reduce seismic demands on tall, slender vessels for a range of support structure stiffnesses, isolation systems, and seismic inputs. Importantly, the reductions in horizontal spectral accelerations in the mid-height isolated vessel from the non-isolated condition were not affected by the stiffness of the support structure. Recommendations are made for analysis and design of isolated equipment and testing of isolators used for equipment protection in nuclear facilities, which are also applicable to other industries.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dioscin inhibits colon tumor growth and tumor angiogenesis through regulating VEGFR2 and AKT/MAPK signaling pathways

Dioscin has shown cytotoxicity against cancer cells, but its in vivo effects and the mechanisms have not elucidated yet. The purpose of the current study was to assess the antitumor effects and the molecular mechanisms of dioscin. We showed that dioscin could inhibit tumor growth in vivo and has no toxicity at the test condition. The growth suppression was accompanied by obvious blood vessel decrease within solid tumors. We also found dioscin treatment inhibited the proliferation of cancer and endothelial cell lines, and most sensitive to primary cultured human umbilical vein endothelial cells (HUVECs). What's more, analysis of HUVECs migration, invasion, and tube formation exhibited that dioscin has significantly inhibitive effects to these actions. Further analysis of blood vessel formation in the matrigel plugs indicated that dioscin could inhibit VEGF-induced blood vessel formation in vivo. We also identified that dioscin could suppress the downstream protein kinases of VEGFR2, including Src, FAK, AKT and Erk1/2, accompanied by the increase of phosphorylated P38MAPK. The results potently suggest that dioscin may be a potential anticancer drug, which efficiently inhibits angiogenesis induced by VEGFR2 signaling pathway as well as AKT/MAPK pathways. - Highlights: • Dioscin inhibits tumor growth in vivo and does not exhibit any toxicity. • Dioscin inhibits angiogenesis within solid tumors. • Dioscin inhibits the proliferation, migration, invasion, and tube formation of HUVECs. • Dioscin inhibits VEGF–induced blood vessel formation in vivo. • Dioscin inhibits VEGFR2 signaling pathway as well as AKT/MAPK pathway.

60 APPLIED LIFE SCIENCES↗

VEGFR tyrosine kinase inhibitor II (VRI) induced vascular insufficiency in zebrafish as a model for studying vascular toxicity and vascular preservation

In ischemic disorders such as chronic wounds and myocardial ischemia, there is inadequate tissue perfusion due to vascular insufficiency. Besides, it has been observed that prolonged use of anti-angiogenic agents in cancer therapy produces cardiovascular toxicity caused by impaired vessel integrity and regeneration. In the present study, we used VEGFR tyrosine kinase inhibitor II (VRI) to chemically induce vascular insufficiency in zebrafish in vivo and human umbilical vein endothelial cells (HUVEC) in vitro to further study the mechanisms of vascular morphogenesis in these pathological conditions. We also explored the possibility of treating vascular insufficiency by enhancing vascular regeneration and repair with pharmacological intervention. We observed that pretreatment of VRI induced blood vessel loss in developing zebrafish by inhibiting angiogenesis and increasing endothelial cell apoptosis, accompanied by down-regulation of kdr, kdrl and flt-1 genes expression. The VRI-induced blood vessel loss in zebrafish could be restored by post-treatment of calycosin, a cardiovascular protective isoflavone. Similarly, VRI induced cytotoxicity and apoptosis in HUVEC which could be rescued by calycosin post-treatment. Further investigation of the underlying mechanisms showed that the PI3K/AKT/Bad cell survival pathway was a main contributor of the vascular regenerative effect of calycosin. These findings indicated that the cardiovascular toxicity in anti-angiogenic therapy was mainly caused by insufficient endothelial cell survival, suggesting its essential role in vascular integrity, repair and regeneration. In addition, we showed that VRI-induced blood vessel loss in zebrafish represented a simple and effective in vivo model for studying vascular insufficiency and evaluating cancer drug vascular toxicities. - Highlights: • In vivo VRI model • Rescue effects of calycosin • Calycosin EC survival pathways.

60 APPLIED LIFE SCIENCES↗

Effect of simvastatin on vascular tone in porcine coronary artery: Potential role of the mitochondria

Statins induce acute vasorelaxation which may contribute to the overall benefits of statins in the treatment of cardiovascular disease. The mechanism underlying this relaxation is unknown. As statins have been shown to alter mitochondrial function, in this study we investigated the role of mitochondria in the relaxation to simvastatin. Relaxation of porcine coronary artery segments by statins was measured using isolated tissue baths. Mitochondrial activity was determined by measuring changes in rhodamine 123 fluorescence. Changes in intracellular calcium levels were determined in freshly isolated smooth muscle cells with Fluo-4 using standard epifluorescent imaging techniques. Simvastatin, but not pravastatin, produced a slow relaxation of the coronary artery, which was independent of the endothelium. The relaxation was attenuated by the mitochondrial complex I inhibitor rotenone (10 μM) and the complex III inhibitor myxothiazol (10 μM), or a combination of the two. The complex III inhibitor antimycin A (10 μM) produced a similar time-dependent relaxation of the porcine coronary artery, which was attenuated by rotenone. Changes in rhodamine 123 fluorescence showed that simvastatin (10 μM) depolarized the membrane potential of mitochondria in both isolated mitochondria and intact blood vessels. Simvastatin and antimycin A both inhibited calcium-induced contractions in isolated blood vessels and calcium influx in smooth muscle cells and this inhibition was prevented by rotenone. In conclusion, simvastatin produces an endothelium-independent relaxation of the porcine coronary artery which is dependent, in part, upon effects on the mitochondria. The effects on the mitochondria may lead to a reduction in calcium influx and hence relaxation of the blood vessel. - Highlights: • Simvastatin produces a relaxation of the porcine coronary artery. • This relaxation is inhibited by mitochondrial complex inhibitors. • Simvastatin alters mitochondrial membrane potential in intact blood vessels. • Simvastatin inhibits calcium influx in smooth muscle cells, prevented by a mitochondrial inhibitor. • Simvastatin-induced relaxations are dependent upon mitochondrial activity.

60 APPLIED LIFE SCIENCES↗