Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Vibroacoustic testing of Space Shuttle thermal protection system panels

The modes and acoustic responses of two panels representing Space Shuttle thermal protection panels were investigated. The panels consisted of flat aluminum sheet stiffened longitudinally with hat-section stringers and corrugated supporting panels representing Shuttle ring frame bulkheads. In addition, one panel had 24 tiles of LI900 silica thermal insulation material and a strain isolator pad bonded to the face sheet. Both panels were found to have approximately eight modal frequencies in the 60 to 500 Hz range, where Shuttle acoustic loads are expected to be high. The strain response to a progressive acoustic wave representing a Shuttle spectrum was characterized by the occurrence of larger strains in the direction normal to the stringers than in the direction parallel to the stringers; three modes in the 100 to 400 Hz range contributed significantly to the strain response.

Rucker, C. E.↗

Hot-air flat-plate solar collector-design package

Report contains design data, performance specifications, and drawings for hot-air flat-plate solar-energy collector. Evaluation consists of tests on thermal performance time constance, and incidence angle modifier test. Results are presented in table and graph form and are analyzed in detail.

Source record↗

Keynote address

The Space Shuttle test program is described. Consideration is given to thermal vacuum testing, static testing, ground vibration testing, high temperature testing, propulsion system testing, etc. Emphasis is placed on the Shuttle test philosophy and how it differs from that of past programs.

Yardley, J. F.↗

Design and test of a prototype thermal bus evaporator reservoir aboard the KC-135 0-g aircraft

The Thermal Bus Zero-G Reservoir Demonstration Experiment (RDE) has currently undergone two flights on the NASA-JSC KC-135 Reduced Gravity Aircraft. The objective of the experiment, which uses a smaller version of the evaporator reservoirs being designed for the Prototype Thermal Bus for Space Station, is to demonstrate proper 0-g operation of the reservoir in terms of fluid positioning, draining, and filling. The KC-135 was chosen to provide a cost-effective and timely evaluation of 0-g design issues that would be difficult to predict analytically. A total of fifty 0-g parabolas have been flown, each providing approximately 25-30 seconds of 0-g time. While problems have been encountered, the experiment has provided valuable design data on the 0-g operation of the reservoir. This paper documents the design of the experiment; the results of both flights, based on the high-speed movies taken during the flight and the visual observations of the experimenters; and the design modifications made as a result of the first flight and planned as a result of the second flight.

Brown, Richard F.↗

Fourteenth Space Simulation Conference: Testing for a Permanent Presence in Space

The Institute of Environmental Sciences Fourteenth Space Simulation Conference, Testing for a Permanent Presence in Space, provided participants a forum to acquire and exchange information on the state-of-the-art in space simulation, test technology, thermal simulation, and protection, contamination, and techniques of test measurements.

Stecher, Joseph L., III↗

Fifteenth Space Simulation Conference: Support the Highway to Space Through Testing

The Institute of Environmental Sciences Fifteenth Space Simulation Conference, Support the Highway to Space Through Testing, provided participants a forum to acquire and exchange information on the state-of-the-art in space simulation, test technology, thermal simulation and protection, contamination, and techniques of test measurements.

Stecher, Joseph↗

Thermal-structural panel buckling tests

A titanium-matrix-composite (TMC) hat-stiffened panel of 61 cm sq area and 3.175 cm thick was nondestructively tested to 649 C to examine its buckling characteristics. Compressive loads were applied to the panel in a 978.6 kN uniaxial load frame system. High-temperature testing was performed using quartz lamp heating. A single-strain-age force/stiffness buckling prediction technique was developed to predict panel buckling loads. For the monolithic panel, these test predictions correlated within 10 percent with a finite-element buckling analyses performed elsewhere. Comparisons between force/stiffness predictions and analyses for the TMC panel are in progress.

Thompson, Randolph C.↗

Hardware and Methods of the Optical End-to-End Test of the Far Ultraviolet Spectroscopic Explorer (FUSE)

The Far Ultraviolet Spectroscopic Explorer (FUSE), currently being tested and scheduled for a 1999 launch, is an astrophysics satellite designed to provide high spectral resolving power (Lambda/(Delta)Lambda = 24,000-30,000) over the interval 90.5-118.7 nm. The FUSE optical path consists of four co-aligned, normal incidence, off-axis parabolic, primary mirrors which illuminate separate Rowland circle spectrograph channels equipped with holographic gratings and delay line microchannel plate detectors. We describe the hardware and methods used for the optical end-to-end test of the FUSE instrument during satellite integration and test. Cost and schedule constraints forced us to devise a simplified version of the planned optical test which occurred in parallel with satellite thermal-vacuum testing. The optical test employed a collimator assembly which consisted of four co-aligned, 15" Cassegrain telescopes which were positioned above the FUSE instrument, providing a collimated beam for each optical channel. A windowed UV light source, remotely adjustable in three axes, was mounted at the focal plane of each collimator. Problems with the UV light sources, including high F-number and window failures, were the only major difficulties encountered during the test. The test succeeded in uncovering a significant problem with the secondary structure used for the instrument closeout cavity and, furthermore, showed that the mechanical solution was successful. The hardware was also used extensively for simulations of science observations, providing both UV light for spectra and visible light for the fine error sensor camera.

Conard, Steven J.↗

A Boresight Adjusment Mechanism For Use in Laser Altimeters

This paper describes the development of the Boresight Adjustment Mechanism (BAM) for the Geoscience Laser Altimeter System (GLAS) Instrument. The BAM was developed late in the integration and test phase of the GLAS instrument flight program. Thermal vacuum tests of the GLAS instrument indicated that the instrument-boresight alignment stability over temperature may be marginal. To reduce the risk that GLAS may not be able to meet the boresight alignment requirements an intensive effort was started to develop a BAM. Observatory-level testing and further evaluation of the boresight alignment data indicated that sufficient margin could be obtained utilizing existing instrument resources and therefore the BAM was never integrated onto the GLAS Instrument. However, the BAM was designed fabricated and fully qualified over a 4 month timeframe to be capable of precisely steering (less than 2 arcsec over plus or minus 300 arcsec) the output of three independent lasers to ensure the alignment between the transmit and receive paths of the GLAS instrument. The short timeline for the development of the mechanism resulted in several interesting design solutions. This paper discusses the requirement definition design, and testing processes of the BAM development effort how the design was affected by the extremely tight development schedule and the lessons learned throughout the process.

Hakun, Claef↗

A Boresight Adjustment Mechanism for use on Laser Altimeters

This paper describes the development of the Boresight Adjustment Mechanism (BAM) for the Geoscience Laser Altimeter System (GLAS) Instrument. The BAM was developed late in the integration and test phase of the GLAS instrument flight program. Thermal vacuum tests of the GLAS instrument indicated that the instrument boresight alignment stability over temperature may be marginal. To reduce the risk that GLAS may not be able to meet the boresight alignment requirements, an intensive effort was started to develop a BAM. Observatory-level testing and further evaluation of the boresight alignment data indicated that sufficient margin could be obtained utilizing existing instrument resources and therefore the BAM was never integrated onto the GLAS Instrument. However, the BAM was designed fabricated and fully qualified over a 4 month timeframe to be capable of precisely steering (< 1 arcsec over 300 arcsec) the output of three independent lasers to ensure the alignment between the transmit and receive paths of the GLAS instrument. The short timeline for the development of the mechanism resulted in several interesting design solutions. This paper discusses the requirement definition, design, and testing processes of the BAM development effort, how the design was affected by the extremely tight development schedule, and the lessons learned throughout the process.

Hakun, Claef↗

Low Conductive Thermal Barrier Coatings Produced by Ion Beam Assisted EB-PVD with Controlled Porosity, Microstructure Refinement and Alloying Additions for High Temperature Applications

Various advanced Hafnia-based thermal barrier coatings (TBC) were applied on nickel-based superalloy coupons by electron beam physical vapor deposition. In addition, microstructural modifications to the coating material were made in an effort to reduce the thermal conductivity of the coating materials. Various processing parameters and coating system modifications were made in order to deposit the alloyed TBC with the desired microstructure and thus coating performance, some of which include applying coatings at substrate temperatures of 1150 C on both PtAl and CoNiCrAlY bond coated samples, as well as using 8YSZ as a bond layer. In addition, various characterization techniques including thermal cyclic tests, scanning electron microscopy, x-ray diffraction, thermal conductivity, and reflectivity measurements were performed. Although the coating microstructure was never fully optimized due to funding being cut short, significant reductions in thermal conductivity were accomplished through both chemistry changes (composition) and microstructural modifications.

Wolfe, Douglas E.↗

Basis for the thermal-vacuum hot dwell test duration

This work suggests that the hot dwell duration for each test should be determined in two steps: a minimum hot duration of 80 hours be required and then followed by specific tailoring be conducted to arrive at the proper test duration.

early test failure distribution Weibull analysis r↗

Aquarius Reflector Surface Temperature Monitoring Test and Analysis

The presentation addresses how to infer the front side temperatures for the Aquarius L-band reflector based upon backside measurement sites. Slides discussing the mission objectives and design details are at the same level found on typical project outreach websites and in conference papers respectively. The test discussion provides modest detail of an ordinary thermal balance test using mockup hardware. The photographs show an off-Lab vacuum chamber facility with no compromising details.

Comision Nacional para el Uso Eficiente de la Ener↗